HomeMy WebLinkAboutNC0046531_Regional Office Historical File Pre 2018AMINNIL m. PAT MCCRORDE A^�T `C)N R Fii�R VAAri�y T' :. SG'CP2tLt7ry. at r sources S. JAY ZIMMERMANi ENVIRONMENTAL QUALITY. Director: December 20, 2016 Mr. Tire Fox, Director of Terminal Operations Lincoln Terminal Company, Inc. 22 South Main Street Greenville, South Carolina 29601 Subject: Compliance Evaluation Inspection Lincoln Terminal Company, Inc. NPDES Permit No. NCO046531 Mecklenburg County Bear Mr. Fox: Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on December 8, 2016, by Mr. Chad Broadway of the Mecklenburg County Water Quality Program (MC +QP). This inspection was conducted as part of a cooperative working agreement between Mecklenburg County and the Division of Water Resources (D ). Please inform the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding a copy of the enclosed report. _. . Broadway was informed during the inspection that the facility has changed Owners from ECO-Energy Distribution to Lincoln Terminal Company, Inc. in February 2016 DWR has no records indicating a permit applicationfor aName/Ownership Change was submitted for approval. Please be advised that NPDES Permits are not automatically transferrable. The new Owner must complete and submit an application for a Name/Ownership Change to DWR for approval to officially change the subject permit to the new Owner. Therefore, a completed application for a Name/Ownership Change (attached to this report) must be submitted to the D (address listed on the application) by January 27 2017. Please also provide a copy of the completed application to this Office (via standard mail or email) to Mr. Wes Bell, D oore ville Regional Office, by the listed date. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (7 4) 2 5-21 2 and/or Mr. Broadway at (744) 280-2926 or via; email at wes.bell(@,ncdenr.izov and chd.roadwa mecklenbur coun e. ov Si care] W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosures: Inspection Report, Name/Ownership Change Application Form, ORC/Backup Designation Form cc: Rusty Rozzelle, MCWQP MSC 1617 Central -Basement United States Envininmental Protection Aaency Form EPA Washington, D.C. 20460 OM8 No. 0-00 r7 Water Compliance Inspection Report Approval''expires 8-31-N Section A: National Data System Wing (I.e., PCs) Transaction a NPDES yrlmolday Inspection TInspector FacType UNCo04e531 11 12 16112108 1117 18 U.. 19 1 < j OU 21 i.� ,11 Inspection work Days Facility Self -Monitoring Evaluation Rating B9 CA .Reserve --•--------- Section 8, Facility Data Name and location of Facility Inspected (For Industrial Users discharging to POT , also include Entry Time/Date Permit Effective Data POTW name and NPDFS oemrit Number) 09:=AM 16112108 1 11tt I Lincoln Terminal Company, Ines 7720 Mount Holly Rd Exit Time/DatePermit Expiration Date P Creek N 2813t? 10.2 1611108 201Gt5i31 Name(s) of Clnsite Representative(s)/Tittes(s)lPhone and FaxNumber(s) tither Facility Data 111 Glenn Fredrick PricatORCl336-996-28411 Name, Address of Responsible ciallTitlelPhone and Fax Number Contacted Tim Fox,22 S Main St Greenville SC 296011Director Terminal No Operationsl664-918-92151 Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance ® Records/Reports Serf -Monitoring Program Sludge Handling Disposal n Facility, site Review Effluent/Receiving Waters Laboratory Section D Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Water Quality Program Meckenburg County MRO 1704-3 91 Signature of nage A evi Agency/Office/Phone and Fax Numbers Date Andrew Pitner MRO 17 S-1699 Ext.2t : 7,,. EPA Form 3 60-3 (Rev 9-94) Previous editions are obsolete ` Page# (cartt.) tations were er. A Water The facility grounds were observed to be well kept and in good condition at the time of inspection. Pa Permit: NCO046631 Owner. Facility. Lincoln Terminal Company, Inc. Impaction Date: IVI inspection Type. compliance Evaluation Bearmift (if the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? MMM M*F*1MMM=*vN1 MUM- - - II I I -► 1; 011i "!:J!'' ITIT, vt IM M M ME MIS P Permit Inspection Date Record Keep Owner. Facility: Ur" Inspedton Type. Col t-aauty nas copy of previous years Rnnuai Report on file for review? U U M u Comment: DUring the ins ecfii n Was were reviewedfrom 11/2015'through 10/2016. All parameters were observed to be collecteLd and anal' ged per 2grmit s ecifications. No effluent limit' violations were observed during the r view period. Collection dates and anal sis results documented on DMRs matched collection times and analysis re§MIts in tale ohain-of-cu od forms. See "Summary" Section for additional comments. Laboratory : Yes' No NA NE Are field parameters performed by certified personnel or laboratory? ' Q ❑ N 0 Are all other parameters(excluding field parameters) performed by a certified tab?' 0000 # Is the facility using a contract tab? ® 0 ❑ 0 Is prosper temperature set for sample storage (kept at less than or equal to fist} degrees ❑ © ■ o Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+i- 0.2 degrees? ❑ No Incubator (B©D) set to 20.0 degrees Celsius +I- 1.0 degrees? © [ Comment: The facilit has contracted with Research and Anal icat Laboratories NC Certification #M to conduct analysis of all permit parameters. Effluent Sampling Yes' No NA NE Is composite sampling flow proportional? 11000 Is sample collected below all treatment units? 0 0 Is proper volume collected? ❑` D 0 ❑ Is the tubing clean? © ® 0 0 # Is prosper temperature set for sample storage (kept at less than or equal to 6.0 degrees 11 0 9 11 Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type a ❑ 11 0 representative)? 2M Is the Does �nGe u+tith acceptable houseke Ono? F Perm{t: NCO046531 owner - Facility: Lincoln Terminal Company, Inspection Date: 12108/2016 Inspection Type: Compliance Evaluation Oaerations & Maintenance bucket and timer to inasur+e flow. Effi& ent Pine Yes No NA ME_ Is right of way to the outfall properly maintained? ® Q ❑ 11 Are the receiving water free of foam other than trace amounts and other debris? 0 ` Q 11 11 If effluent {diffuser pipes are required} are they operating properly? Q © , ❑ Comment: The facilily was not dischargingdischaLging at the time of inspection. No visual signs of pollution were observed below the outfall. Page# 5 DONALD R. VAN E NPDES Permit Number: NCO046531 information is required from facilities. It only changes the method by which information is provided (ie., electronic rather than paper -based). EPA is phasing in the requirements of the rule over a 5-year period. The two phases of the rule, and their key milestones, are: • Phase 1 —Starting on December 21, 2016, regulated entities that are required to submit Discharge Monitoring Reports (DMRs) will begin submitting these reports electronically. If you are currently reporting your DMR data electronically using eDMR, then you simply need to continue reporting in the same way as you are now, The key change is that, starting on,December 21, 2016, electronic reporting of DMRs will be required, instead of voluntary. • Phase 2 — Starting on December 21, 29�% regulated entities that are required to submit certain other NPDES reports will begin submitting these reports electronically. Reports covered in the second phase include Notices of Intent to discharge in compliance with an NPDES general permit, Sewer overflow/Bypass Event Reports, and a number of other NPDES program reports. Incorporating Electronic Reporting Requirements into NPDES Permits The NPDES Electronic Reporting Rule requires authorized NPDES programs to incorporate electronic reporting requirements into NPDES permits beginning December 21, 2015. Under the new rule, the electronic reporting process supersede ' s the paper reporting process, According to our files, your NPDES permit became effective after November 2013, and should contain the requirement to electronically report your Discharge Monitoring Reports using NC DWR's eDMR system. In addition to requiring permittees to report information electronically, the rule also requires permittees to identify the initial recipient for the NPDES electronic reporting data [see 40 CFR 122.41(1)(9)]. initial State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 9198076300 recipient of electronic NPDES information from NPDES-regulatedfacilities (initial recipient) means the entity (EPA or the state authorized by EPA to implement the NPDES program) that is the designated entity for receiving electronic NPDES Data [see 40 CFR 127.2(b)]. Permittees are required to electronically submit the required NPDES information to the appropriate initial recipient, as determined by EPA. ByJuly 18, 2016, EPA must identify and publish on its web site and in the Federal Register a listing of initial recipients by state and by NPDES data group. Once available, you can use EPA's web site to find out or determine the initial recipient of your electronic submission. NC DWR has submitted a request to EPA to be the initial recipient for the following NPDES data groups: 1. Discharge Monitoring Reports; 2. General Permit Reports [Notices of Intent to discharge (NOls); Notices of Termination (NOTs)]; 3. Pretreatment Program Reports; and 4. Sewer Overflow/Bypass Event Reports EPA's web site will also link to the appropriate electronic reporting tool for each type of electronic submission for each state. Instructions on how to access and use the appropriate electronic reporting tool will be available as well. For more information on EPA�s NPIDES Electronic Reporting Rule, visit electron ic-[gp2[jj�. For more information on electronic reporting to NC DWR, visit or contact Vanessa Manuel at 919-807-6392 or via email at Yanessa.ManueI@ncdenrgjov. Sincerely, je�fre/y 0. po%Afjoa� for S. Jay Zimmerman, P.G. Cc: NPDES File Central Files foveano Mr. Ker ECO-Er 1111C 11-1 YYYVA A*IWA" WSENA Nor I C June 3, 2015 [ala, Terminal Superintendent action -Charlotte, LLC lvd. Suite 500 Subject: Draft NPDES Permit NCOO, ECO-Energy Distribution -Chi 7720 Mount Holly Road, Cha Mecklenburg County the Environmental Protection Agency (EPA). The Division anticipates that these regulations will be adopted and is beginning implementation. The requirement to begin reporting discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report (eDMR) internet application has been added to your NPDES permit. [See Special Condition A. (4.)] For information on eDMR, registering for eDMR and obtaining an eDMR user account, please visit the following web page: httD://-oortal.ncdenr,or&web/wci/admin/bop-/ii)tdedmr. For information on EPA's proposed NPDES Electronic Reporting Rule, please visit the following web site: htti)://www2.eDa,v-ov/comt)liance/DroDosed-nDdes-electronic-re,00rtinp--rule, 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919-807-6300 \ tnternet: www.nmaterquality,org An EquM OppoftuOy \ Affirmabye Action Employer— Made in pal by wyded paper Mr. Fudala June 3, 2015 Page 2 of 2 Concurrent with this notification, the Division will solicit public comment on this draft by publishing a notice in newspapers having circulation in the general Mecklenburg County area, as required by the NPDES Program, Please provide your comments, if any, to me via email [derek.denard@ncdenr.gov] or write to my attention care of DENR DWR / NPDES Program no later than July 10, 2015, Your written comments are welcome but not mandatory. Following the mandatory 30-day public comment period, the Division will review all pertinent comments on your pen -nit draft, and take appropriate action prior to issuing your NPDES permit final. If you have questions concerning this draft, please e-mail me or call my direct line (919) 807-6307. Sincerely, Derek Denard, Environmental Specialist Division of Water Resources, NCDENR Enclosure: NPDES Permit NiC0046531 (renewal DRAFT) he: NPDES Program Files [draft permit and Fact Sheet] ec: MRO / Michael Parker [michael.parker@ncdenr.gov] [draft permit, Fact Sheet] MRO / Wes Bell [wes.bell@ncdenr.gov] [draft permit, Fact Sheet] Richard Farmer [Richardfarmer@meeklenburgeountync,gov] [draft permit, Fact Sheet] MRO / Keri Cantrell [keri.cantrell@ncdenr.gov] [draft permit, Fact Sheet] Wastewater Operator Certification Group / Steve Reid [steve.reid@ncdenr.gov] [draft permit, Fact Sheet] Aquatic Toxicology Unit/ Susan Meadows [susan.nieadows@ncdenr.gov] [draft permit, Fact Sheet] Kenneth R. Fudala, ECO-Energy jerminal Superintendent [kenf@eco-energy.com] Permit', STATE OF NORTH C. DEPARTMENT OF ENVIRONMENT AT DIVISION OF WATER f LI -11P E R M TO DISCHARGE WASTEWA NATIONAL POLLUTANT DISC ( (NP DES) A ICES t i &AAoRr=SV11 Federal Water Pollut "" rntrol Act, as amended"41., 10 ECO-Energy Disti C1h� `INQtte LL he"', gi gsi is hereby authorized t e astewat z11 outfalls located at t'e `��, ` �°vai§ � EC G )Ctergy \ in s filar � LLC rat no �o ttt+u214 «m,�� �. ;t�buta ; Gum Branch within the Catawba River Basin o receiv in � signate ti in actor apt lim s, mono eq ments and other conditions set forth in Parts c� ag ", i I, II,' III a hereof: S i ry r,. This permit s ecome effects 201. 4 This permit and auth Lion to arge shall expire at midnight on :May 31, 2020. 40 11 \� }�Ci Signed this day E ��.Y�`" 1. S. Jay Zimmerman, Director Division. of Water Resources By Authority of the Environmental Management Commission Page l of 8 Permit NCO046531 SUPPLEMENT TO PERMIT COVER SMET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective, Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. ECO-Energy Distribution C te, LLC is hereby authorized to: 1. continue to operate a Water Pollution Cont ��tem treating sto ter runoff from truck loading racks consisting of, , o • Oil/water separator Y 4 i u` •; Carbon adsorption`s • Polishing pond located at ECC1-Energy Distributto�harl�C, 77��Ho11y Read, Paw Creek, Mecklenburg County end j 1 l 2 \ 1 tt` t S ll i ,`, l fitt 2. discharge said treattn o� facility through Outfall 001, at a location specified on the attached map, into an"Ifed trio to Gum Branch [stream segment 11-120-5], a waterbod currently classy s, �t sated within subbasin 03- - 4 [HUC. 030501 11 of the Catawba River Basin. Page 2 of Permit NCO( 50050 Solids C0530 30.0 mg1L Ag ale 32730 t ,U) 34010 Im SGT- 0055i, Monthly 34030 19Izg/L Monthly l nthly t loll �v} I 11 i 343 Monthly et' e� 696 y;t Monthly ag/L) . Monthly ��1 s vt 4 t,� .s13 �,l..l�4k �G �2s�i�: Monthly »Y7i aib',�j:� . Semi- annually Acute Toxti �. y\ r Annually Grab Effluent Footnotes: atiVIM ' "Vl �yti l . No later than 270 from the five date of this permit, the permittee shall begin submitting discharge on ,_ lY arts electronically using the Division's eDMR application system. [see'" . Flaw shall be monitored reach discharge event — During periods of no flow, the Permittee shall submit a signed, monthly Discharge Monitoring Report (DMR) indicating "No discharge." Flow may be monitored using any one of four methods: a) measure flow continuously (via flow meter, totalizer preferred); b) calculate flow (see Rational Equation ) based on total rainfall per unit area draining to the outfall; c) estimate flow at 20-minute intervals during the entire discharge event; or d) report flaw based on discharge pump lops. 3. This sample to be collected concurrently with annual Acute Toxicity. Page 3 of [I 5A NCAC 02B . 500 a Permit N )NITO(ANNUAL) seq. ] • ,ntative efflue e below all w Water Sciet 11 ail x q ests, as isured an \gf ,bieve test co ions as specified in j w.a 4-1623 eats or limits. require immediate fol�� p test es be completed no later than the last day of the month following the month of the initial` mom ' � ,y ."'ry air �`'� Page 5 of 8 Permit NCO046531 A. (3.) FLOW MEASUREMENT RATIONAL [G.S. 143-21 .1 b ] The Rational Equation. Q=K CI , where. Q = flow (peak flow rate (cfs or m/sec) Ku - units conversation factor = 1.008 for U.S. standard units (usually ignored becauseit is so dose to 1), or 0.278 for SI units C = dimensionless runoff coefficient for the watershed, loosely defined as the ratio of runoff to rainfall 1 intensity of rainfall taken from the inten�., , ration -frequency curves for the specified design return j t the time of concentration, to (in/h or m /h). tAwe o entration (time r after the beginning of rainfall c� when all g g p6ifts of the drainage basin are contrzbuttn §1iultaneously to ftat the outlet) A area of tributary watershed (ate or km2) ti t i t�l The rational equation is used tct, elate the runo region, given. t � I lFy r • the runoff coefficient �x infiltratz� ses in'42111 the region), s • the rainfall intensity to tlfeiot � • the time,,,l ,doff to travpper hes to its outlet, and 211. bti • the to, e area. y 1 t1 .. e N t I s 4 i h •' L IF 5 X \ t u i 1 y ; Page 6 of 8 REPORTS [.S. 143. 215.1(b)] electronic submittal DENS' Permits): tendon Reports s z F it ang sections pr- t {lu "tC l 1 ' f kvt l� { permit, the pei WR's Elect. 2 Permit 1 Z follo 'address, { , NC DENIM R 1 InformProcesN Unit MEN ATTENTICJ�{ tral Piles R 1617 Mail Serve . nterf Raleigh, North Car 27 617 If a permittee is unable tc the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access, then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms (MR 1, 1.1, 2, ) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. Requests for temporary waivers from the NPDES electronic reporting requirements must be submitted in writing to the Division for written approval at least sixty (60) days prior to the date the facility would be required under this permit to begin using eDMR. Temporary waivers shall be valid for twelve (12) months and shall thereupon expire. At such time, DMRs, shall be submitted Page 7 of Permit NCO04 531 electronically to the Division unless the permittee re -applies for and is granted a new temporary waiver by the Division. Information on eDMR and application for a temporary waiver from the NPDES electronic reporting requirements is found on the following web page: httt):llportal.ne enr.or /weblwclladmin/bo i uledmr Regardless of the submission method, the first DMR is dday of the month' following the issuance of the permit or in the case of a new facility, \ Mast day of the month following the il commencement of discharge. t 2. Sitinatory Re uirements fSup0ements Sectio 1..,. b and ' " series Section B. 11. d All eDRs submitted to the permit issuing at shall be signed by son described in Part Il, Section B. (i I.)(a) or by a duly authorized rep tative of that person as, art II, Section B. (l i )(b. A person, and not a position"-t be del ted signatcrr'ority for eDMR d reporting purposes,; For eDMR submissions, the person ���d submitti DMR must obtain an eDMR user account and login credentials to acres 4e a stem. "more information on Forth Carolina's eDMR system, registering fob` Ml ltainin'pMR user account, please visit \ \. the following web paq�� 1 �\ htt :11 ortal.ncded,v W eblw � "" inlbo aapgi mg'w Certification. Any perubmz v an lectroz�MR using the state's eDMR system shall make the follow fiction y} t �'��� N( ER STATEMENTS OF CERTIFICATION WILD le�` underaenaltP�� tlZ�� docuerztand all attachments were prepare render nay directz�3 r supervisir�n z r��ordan��h a system designed to assure that qualiftedpersonnel properly�Wr and evalua' zrzforzr n submitted. Based on my inquiry of the person or why \ ge the cyst IN — persons \fir° those persons directly responsible forgathering the information, 41 the information rued is tQ best of my knowledge and belief true, accurate, and complete. I am aware that teeft sign 15 t penalties forty submitting false information, including the ter. possibility of fuzes a "` � �z ent for knowing violations. . Records Retention (SaaDl'ments Section D. 6.}1 The permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. Page of DENR / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT DEVELOPMENT NPDES Permit NCO046531 Derek Denard, Compliance & Expedited Permitting Unit i/ 919-807-6307 081un2015 16s ti ' ECO-Energy Distribution -Charlotte, LLC ti. n, .h 725 Cool Springs Blvd. Suite 500, Franklin, TN 3707 ` I M ti 7720 Mount Holly Road, Charlotte, NC 28214 z. not limited 100°!o Industrial, fuel (bulk storage) .. PC-1 Mecklenburg Renewal MR s to Gum urtl Branch �` a... �. "�WS-1 Y UR w 4 r tir�taWl?a [11-120-5] -08-34 �4 s 0 t No Data J ti� � i"i its st ti , / �: No �.. 0�< Y. F15SW 100% LYl t. Island Lake, NC 2 p .{} Facility Summary This facility is an industrial (flow <1 MGD) collecting stormwater from a Surface -Water Pollution Prevention System in proximity to above -ground storage tanks (ASTs). Facilitiesinclude surface bulk_ storage of petroleum hydrocarbon fuels in excess of one million gallons and fuel -truck loading racks. There are no significant changes to this facility since the last permit renewal. The facility consists of the following wastewater treatment units: • Oil/water separator • Carbon adsorption • Polishing pond Monthly�avera e FLOW fMGD) — Last 36 months Mar2012-Feb2 15. [Ave 0,110 MGD; Maximum, Monthly average flow = 0.406 MGD, Minimum, Monthly average flaw = 0:0021 Toxicity This permit requires Acute Toxicity Monitoring testing using Pimephales pro elan to be performed on an annual basis as a 24-hour static [TAE6C]. The facility has passed toxicity monitoring in March 2015, The 2013 and 2014 did not indicate pass/fail on DM 2 and the attached effluent toxicity reporting form AT -I did not indicate pass/fail. However, the forms indicated zero mortality (0%). Compliance History -- The facility had a TSS limit violation with 110 mg/L (limit 45 mg/L) in October 2013. �ttEu� 1 For Renewal — This permit reflects discharge at Outfall 001; DWR updated the following: • added updates to facility map, outfall locations and parameter codes • added Monthly Average Limit of 30.0 mg/L for Total Suspended Solids (T S) • for Oil & Grease [00556] the parameter code remains the same for submitting DMR/eDMR, but EPA method 1664 (ST-HEM) is used with results in mg/L • replaced Phenol (single compound) [34694] with Total Recoverable; Phenolics [32730] • added Electronic Reporting - Discharge Monitoring Reports page Section A. (4.), Stream — Discharge from WWTP for Outfall 001 is into an unnamed tributary to Gum Branch [Stream Segment I 1-120-5]. The segment is not listed in the 2014 North Carolina Integrated report or 303(d) list. A — A Reasonable Potential Analysis (RPA) was conducted on Turbidity (34694) because Discharge Monitoring Reports (DRs) reported concentration below method -detection levels (MDLs) for the past four and a half (4 /z) years (Sept20l I-Feb2015) of data. [MTBE, Toluene, Benzene, Ethyl benzene, Single Compound Phenol, Naphthalene, EPA Method 625, and Xylene were below method -detection levels — see attachment] Turbidity did not show reasonable potential to violate state WQS; however, since the predicted' maximum effluent concentration was greater than 5'0% of the allowable concentration quarterly monitoring was maintained. Fact shQc iat) IeN' A :."W 5 -- NPIA'S "vOW4053I Page FILEI North Carolina Department of Environment and Natural Resources Division of Water Resources Water QualityRegional Operations Section Pat McCrory Thomas A. Reeder John E. Skvarla, Ill Governor Director Secretary February 6, 2014 Mr. Ken Eudala, Terminal Manager Eco'-Energy Distribution -Charlotte, LLC 7720 Mount Holly Road Charlotte, ;North Carolina 26130 Subject: Notice of Violation — Effluent Limitation Tracking #: NOV-2014-LV-00 6 ECO-Energy Distribution -Charlotte, LLC NPDES Permit No. NCO046531 Mecklenburg County Dear Mr. Fudala: A review of the October 2013 self -monitoring report (DMR) for the subject facility revealed a violation of the following parameter at Outfall 001 r Date Parameter eported Value Permit Limit 1011113 Taal suspended solids 110.0 mg1L 45.0 mg1L (Daily maximum) Since your October 2013 DMR prodded additional information regarding the noted effluent limit violation, a response to this notice is not required. Thank you; for your continued' cooperation with the Division of Water Resources and your efforts to comply with the requirements of your permit. The Division of Water Resources may pursue enforcement actions for any; future' violations of your permit. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities,` then you may wish to consider applying for a' Special Order by Consent. Sincerely, Michael L: Parker Water Quality Regional Operations Section Mooresville Regional Supervisor cc: Point Source Branch R. Rozzelle, MCWQP MA Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville: NC 28115 One Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 C}1" It c` l"( i1 Internet: http:l/portal.nedenr,org/web/wq An Equal Opportunity 1 Affirmative Action Employer - 30% Recycedd{10% Post Consumer paper AwU14,711Y NCDENR FILE North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Thomas A. feeder John E Governer acting Director June 14, 2013 r. Ken Eudala, Terminal Superintendent Eco-Energy Distribution Services 7720 Mt. Holly Road Charlotte, NC 28214 SUBJECT: Compliance Evaluation Inspection Eco-Energy Distribution -Charlotte. LLC NPDES Permit No. NG0046531 Mecklenburg County, North Carolina Dear Mr. Eudela Enclosed is a copy of the Compliance Evaluation Inspection report for the inspection 1. Sincerely, for Michael L. Parker Regional Supervisor Surface `cater Protection )sure rusty Foelle, MCWQP it Off b- ,nterAu., Suit 301, too villa NC 811 �� car M l Fax: (704) 3- 0401 Customer 5 rvicw.1-877-6 3-6748 GENERAL: This is the first Compliance Evaluation Inspection for the facility. The fre in April 2012. PERMIT: The current NPDES permit became effective on April 25, 2012, and exr 70�7 TFUUM rTn* I .rea. lity's permit became active The facility ORC possesses the appropriate operator certification. The facility has not officially designated a back-up ORC. The facility must designate a back-up ORC with the appropriate certification, RECORDSIREPORTS: Discharge Monitoring Reports (DMRs) were reviewed for the period April 2012 through December 2012. These reports appeared to be properly completed, Facility personnel maintain clear and organized records and reports. Copies of effluent analytical results, discharge logs, and flow measurements are readily available at the site. FACILITY SITE REVIEW: The facility is engaged in gasoline, diesel, and ethanol fuel storage and distribution. Discharges from the oil/water separator flow into a containment tank before being treated by the carbon absorption filters. The discharge from the filters is held in the final containment basin until it is manually released. All of the major components of Ouffall 001 treatment works were in service and appeared to be operating properly at the time of inspection. FLOW MEASUREMENT: Flow measurement is accomplished by calculating the total rainfall over the drainage area excluding the built -upon areas. LABORATORY: The permittee contracts with Research Analytical Laboratories, Inc. (NC Laboratory Certification # 34) to perform all analyses specified in the permit. Research Analytical Laboratories, Inc. was not evaluated under this inspection. EFFLUENTIRECEIVING WATERS: Outfall 001 discharges to Gum Branch, which is a Class S-IV water within the Catawba River Basin. Ouffall 001 was not discharging at the time of the inspection. SELF -MONITORING PROGRAM: DMRs and analytical reports were reviewed for the period April 2012 through December 2012, The DMRs indicate that the facility was in compliance with permit monitoring requirements and discharge limits during this review period. OPERATIONS & MAINTENANCE: The facility and site appeared to be: well operated and maintained. The discharge valve for Outfall' 01 remains locked and must be manually opened for discharge to occur. August 24, 2012 Regional Office A !J G ast Center Avenue, Suite 301 asville, NC 28115 ,.t:NPDES Permit NCO046531 7720 Mount Holly Road Charlotte, NC 28130 r Madam: AR olnnrsvp OVUE IRse, Energy Distribution -Charlotte, LLC. This permit is for the treatment and discharge of storm water from the loading rack area at the subject terminal. Initial operation of the terminal will occur in early September, and the wastewater treatment system will be operated in accordance with the NPDES permit. if you or your staff would like to visit the site and inspect the wastewater treatment facility, please contact me. I am, by copy of this letter, advising the Mecklenburg County Water Quality Program Supervisor that the facility is being put into operation, if you have any questions or need additional information, please do not hesitate to contact me. Sincerely, ex � ECO-Energy Distribution -Charlotte, LLC Ken Fudala Terminal Superintendent Cc: Mr. John McCulloch, Environmental Water Quality Supervisor Mecklenburg County 700 N. Tryon Street Charlotte, NC 28202 7720 Mt, Holly Road , Charlotte, NC 28214 - Phone 704.392.6000 - Fax 704,392.0249 A74LA. NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue (Teen H. Sullins Governor Director October 21, 2009 John, Funk Refuel America, Inc. PO Box 78 Paw Creek, NC 28130-0078 Subject: Renewal Notice NPDES Per mif NCO046531 Charlotte Terminal Mecklenburg County Dear Permittee: Your NPDES permit expires on May 31, 2010. Federal (40 CFR 122.41) and North Carol rent permit. If you have already mailed your renewal application., ackage must be sent to the Division postmarked no later than Decembe wal by this date may result in a civil penalty assessment. Larger penalti )n the delinquency of the request. Discharge of wastewater without a valid permit would violate North Carolina General Statute 143-215.1; unpermitted discharges of wastewater may be assessed civil penalties of up to $25,000 per day. If all wastewater discharge has ceased at your facility and you wish to rescind this permit, contact me at the telephone number or address listed below. Use the enclosed checklist to complete your renewal package. The checklist identifies the items you must submit with the permit renewal applicatiom, If you have any questions, please contact me at the telephone number or e-mail address listed below, Sincerely, Charles H. Weaver, Jr. NPDES Unit cc: Central Files 6 J"puat0ft protection NPDESEC"4'­' 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One 512 North Salisbury Street, Raleigh, North Carolina 27604 NofthCarohna Phone: 919 807-6391 /FAX 919 807-6495 1 charies,weaver@ncdenr,gov Natzmally An Equal Opportunity/Affirmative Action Employer — 50% Recycled/1 0% Post Consumer Paper 'rhe following items are RE A saver letter requesting r( issuance of the last permit. S '17he completed application Representative. Submit one , S7 If an authorized Represento the renewal package, written such Authorized Representat narrative description of th solids) generated >during was plan (or the permitted facilit rPDES PERMIT N O046531 CHARLOTTE TERMINAL 4ECKLENBURG COUNTY RJRED for all renewal packages. ewal of the permit and documenting any changes at the facility since b it one signed orig inal and two copies. form (copy attached), signed by the pennittee or an Authorized ned original and two copies. ve (such as a consulting engineer or environmental consultant) prepares locumentation must be provided showing the authority delegated to any 'e (see Part H.B.11.b of the 'exis ' g NPDES pen -nit). sludge many emea t plan for the facility. Describe how sludge (or other ,water treatment are handled and: disposed. If your facility has no such sloes not generate any solids, explain this in writing.; Submit one signed B The followinitems mint he submitted by any Munici al or Industrial facilities dischar "n process wastewater: Industrial facilities classified as Primary Industries (see appendices A-D to `Title 40 of the Code of Federal Regulations, Part 122) and ALL Municipal facilities with a permitted flow � 1.0 MGD must submit a Priority Pollutant Analysis (PPS) in accordance with 40 CFR Part 122.21. The above requirement does NOT apply to privately o ed facilities sties treating 100 domestic wastewater, or facilities which discharge non -process wastewater (cooling pater, filterbackwash, etc Send the completed renewal package to: Mrs. Dina Sprinkle NC DENR / DWQ / Paint Source Branch 1617 Mail Service Center Raleigh, NC 27699-1617 a• NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Goleen H. Sullins Dee Freeman Governor Director Wetary July 28, 2009 w, ff ate. a Mr. hack Carlisle, Registered Agent Charlotte Terminal 1, LLC 109 Willesden Drive Cary, NC: 27513 Subject: Request for Status Update DES Permit NCO046531 Refuel America Terminal 7720 Mount holly Road, Charlotte, NC 2 130 Mecklenburg County` Dear Mr. Carlisle: The Division of "hater Quality is aware that Charlotte Terminal I, LLC recently purchased the Refuel America. Terminal at 7720 Mount Holly Road, Charlotte, NC;. The previous owners held a Clean Water Act National Pollutant Discharge Elimination System (NPDES) permit for the facility. The permit authorized the discharge of wastewater at the site after it had passed through a treatment system consisting of an oilwater, separator, carbon adsorption, and a finishing pond. The NPDES pe it : requires proper operation and maintenance of the wastewater treatment system as well as monitoring and reporting of the duality of the effluent released. The Division of Water Quality is requesting an update on your plans for the facility and a status report with regard to the current state of operations at the facility. If operations will require treatment and discharge of wastewater, you will need to assume responsibility for the NPDES Permit. A form for transfer of ownership of the permit can be found at htt ///h o.e r.state.nc us SAES/docu ents.ht 1, at the bottom of the page. If you have any questions about this letter or the NPDES permitting process please contact me at (919) 807-6398 or via e-mail at` bob.sledge@nedenr. ov. Since ly, Bob Sledge NPDES Western Unit cc. NPDES Pile Central Riles; :Mooresville Regional Office Mecklenburg County 1617 Mail' Service Center, RaWgh, North Carolina 27699-1617 One Local& 512 N. Salisbury St. Raleigh, North Carolina 27604 N o Carolina Phone: 919-807-630D t PAX: 919-807-64921 Customer Service:1.877-623-6748 i+ Internet www.ricwaterquality,org An Equai Opportunity \ Affirmative Action Employer ( A 7" Michael F: Easley, Governor William 6, Ross Jr., Secretary ice"° North Carolina Department of Environment and Natural Resources ( Coleen H. Sullins,' Director Division of Water Quality October 8, 2007 Mr. Kit Bryan "�. Refuel America, Inc. u Rkm 6000 Fairview Road, 12`h Floor Charlotte, NC 28210 40 SUBJECT: Request for Status Update Refuel America, Inc. — Refuel Terminal Operations - Charlotte ICES Permit Number NCO046531 NC E Mecklenburg County M-Surfs4 1 f Dear Mr. Bryan: The Division of Water Quality is aware that Refuel America, Inc. recently purchased the subject facility and had the NPDES permit issued in its name. Information provided by Refuel America, Inc.°s representatives, as found in our files, stated the company planned to test the equipment at the site to ensure all was in working circler, and that no fuel would be shipped into the site until this was completed. While the DES permit requires routine monitoring to be conducted on regulated discharges and monthly reports be submitted documenting the results of monitoring, these requirements have been suspended until the facility exhibits potential to actually dischargetreated wastewater (in this case treated stormwater from a petroleum bulk storage facility). Because some time has passed since the permit was issued in Refuel America, Inc.°s name, and because only one discharge monitoring report has been submitted to the Division from the facility (results of hydrostatic tank testing discharge from January 2007), at this time the Division requests that you provide it with a status report with regard to the current state of operations at the :facility. If the facility is not currently operational (is not receiving/distributing product to or from its tanks), please provide us with an estimate as to when this will occur and when you will begin to submit discharge monitoring reports. This report does not need to be detailed; it simply needs to be a brief and accurate description of operations as they apply to your requirements as a NPDES per ittee. e appreciate your assistance in this matter. If you have any questions about this letter or discharge monitoring reports, please contact me at (1) 733- 083, extension 547,tar via e-mail at bob.sledge@ncmail.net. Sincerely, Bob Sledge NPI ES Western Unit c: NPIES File Central Files MMMONNNOWNWOMM Norihurolina ;Nrllc; North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (91 ) 733-7015 Customer Service Internet: wy newater to tafity ore Locatiow 512 N. Salisbury St. Raleigh, NC 27604 Fax (919) 733-2496 1-977-623-6748 An Equal Opportunity/Affirardive Action Employer — 500% Recycledl100/. Past Consumer Paper North Carolina Secretary of Mate _ ` cickPage 1 of 1 � W North Carolina l ". A M ENT HE :lie F Marshall ` Secretary SECRETARY RY F STATE ` PO Box 29622 Raleigh, NC 27 2 -0 2 i91907-2 ii a CORPORATIONS Date: 5122/2009 Corporations Home dick here to: Search By Corporate lame View Document Filings I Sign Up for Notifications j Search For New & Dissolved Print apre-populated Annual Report Form I Annual Report Count I File: ��t'"? r Search By Registered Agent an Annual Report I Important Notice Corporation Names Resale of Ticket nline ,Z 0 Corporations FAQ Name Name Type Homeowners` Association FAQ Charlotte Terminal I, Legal Tobacco Manufacturers LLC Unincorporated Non -Profits Limited LiabilityCompany Information Dis%olution Reports Non -Profit Reports SOSI : 1079449 Verify Certification Status: Current -Active Online Annual Reports Date Formed: 1/14/2009 LINKS & LEGISLATION Citizenship. Domestic KBBE B28 Annul Reports State of Inc.: NC SOSID Number CorrectionDuration: Perpetual 2001 Sill Summaries Registered Agent 1999 Senate bills Annual Reports 1997 Agent Marne. Carlisle, Jack Corporations 1997 Registered Office Address: 109 Willesden Dr, Professional Corporations Cary NC 27513 Register for E- ^rocurement Registered Mailing 109 Willesden Dr. Dept. of Revenue Address: Cary NC 27513 ONLINE RIMS Principal Office Address. 109 Willesden Dr. Cary NO 27513 Start An Order Principal Mailing Address: 109 Willesden Dr. New Payment Procedures Carr NC 27513 CONTACT T US Corporations Division TOOLS Secretary of State Mona Secretary of State Site Map Printable Page, http:// .secretary.state.nc.us/corporations/Corp.aspx?Pitemld=903 744 6/22/2009 0 Michael F. Easley Governor William G. Ross, Jr., Secretary Department of Environment and Natural Resources 'C Gregory J, Thorpe, Ph.D., Acting Director Division of Water Quality February 8, 2002 ,d Reid, Terminal Manager ventral Petroleum Corporation ice Box 78 ek,'NC 28130 SUBJECT: Compliance Evaluation Inspection Crown Central Petroleum Corporation Charlotte Terminal NPDES Permit No. N O046531 Mecklenburg County, NC Reid: )n January 24, 2002, Mr. James Wilson of the Mecklenburg County Department o mental'Protection conducted an inspection at the subject facility. This inspection was ed as part of a cooperative working agreement between. Mecklenburg County and the Division of Water Quality. i ne enc osea report snowu vc sGtt-�xjttatacxtva y. If you have any questions concerning this report or any other matters, please do not hesitate to call Mr. Richard Bridgeman or me at this Office. Sincerely, D. Rex Gleason, P. E. Water Quality Regional Supervisor Enclosure cc: Rusty Rozzelle, MCDEP JPW File: WQ 0046531.102 04 NffD Customer Service Division of Water Quality 919 North Main Street Mooresville, NC 28115 Phone .(704) 663-169 1 800 6 -7746 Fax (704) 663-6040 United States Environmental Protection Agency, Washington, DC 20460 ' Ank NPDES Compliance Inspection Report North Carolina Department of Environment and Natural Resources Division of Water Quality, Mooresville Regional Office NC', • • • "# OMB No040-0003 Approval Expires 7/31/85 Section A: National Data System Coding Transaction Code NPDES Permit No. Y OtDAY Inspection Type Inspector Facility Type N 5 NC0046531 02/01/24 C C 2 Remarks: Inspector: Mecklenburg County Environmental Protection Inspection Work Days Facility Self -Monitoring Evaluation Rating BI QA ...........Reserved............ 0.5 5 N N Section B: Facility Data Entry Time. Permit Effective :mate: Name and Location of Facility Inspected: 9 40 am September 1, 2001 Crown Central Petroleum Corporation Exit Time: _ 7720 Mt. Hotly Road 10:30 am Permit Expiration Date: Paw Creek Date. June 30, 2005 Mecklenburg Count , NC I Janua 24,2002 Name(s) of On -Site Representatives-------Title(s)--- -- --- Phone No(s): Mr. Floyd Reid Terminal Manager 704132-2320 Name and Address of Responsible Official: Title: Mr. Floyd Reid Terminal Manager Crown Central Petroleum Corp. — Charlotte Terminal Phone No. Contacted? P.O. Box 78 Paw Creek., NC 28130 704133 -2320 Yes Section C. Areas Evaluated During Inspection Permit Flow Measurement Z Operations & Maintenance C] Sewer Overflow Records/Reports Self -Monitoring Program (3 Sludge Handling/Disposal Q Pollution Prevention Facility Site Review Q Compliance Schedules ( Pretreatment Program Q Multimedia Effluent/Receivina Waters Laboratoa Stormwatr Other: Section D: Summary of Findings/Comments All areas are rated satisfactory unless otherwise indicated. See Attached Sheet(s) for Summary Signature(s) of Inspectors: Agency/Office/Telephone: Date: James P. Wilson,11 MCDEPI(704) 336-5 00 January 31, 2002' Signature of'Reviewer: Agency/Office Date: EPA Form 3560-3 (Revised -85) Previous Editions are Obsolete facility was last inspected by MCDEP on April 12, 2001. A Compliance Evaluation .eport was issued on April 26, 2001. facility recently received a permit renewal. The new permit became effective on , 2001 and will expire on June 30, 2005. The NPDES facility consists of a loading iter treatment system including an oil/water separator, an equalization tank and two arbor absorption its in series which discharge to the storm water dike containmen �urrent permit properly describes the facility and appears adequate for the storm Ovate oading rack wastewater being discharged. vg'veiv" jD141R. reports, and logs are clear and well maintained; no discrepancies were noted. FACILITY SITE REVIEW: The site is engaged in gasoline and fuel oil storage and distribution. The combined storm water and treated loading rack washwater are then discharged through outfall 001. All petroleum collected from the oil/water separator is returned to the premiurn gasoline storage tank (Tank #1), The discharge valve for outfall 001 is kept closed and locked, except during discharge events. FLOW MEASUREMENT: Flow measurement is accomplished by calculating the volume of water in the spill control basin prior to discharge. This method is allowed by the permit. LABORATORY: Analysis of effluent samples is performed by Test America. Test America is certified by the State of North Carolina to perform analysis on all parameters specified in the permit. Test America was not evaluated under this inspection. -qqqq EFFLUENT/RECEIVINGWATERS: The facility was not discharging at the time of the inspection. The facility discharges to an unnamed tributary to Gum Branch, which is a Class WS_ V water in the Catawba River Basin, via a riprap-lined ditch: SELF -MONITORING PROGRAM: DMRs were reviewed for the period December 2000 through November 2001. There was a reported discharge during April 2001 only, the report for April 2001 indicates that the facility was meeting permit effluent limits. Records indicate that all parameters are being monitored in accordance with permit it requirements. OPERATIONS MAINTENANCE: The facility and site appeared well operated and maintained. Storm water in the diked basins is visually inspected for the presence of petroleum sheen prier to discharge. Crown Central Petroleum Corporation Refiners 1 marketers of petroleum products & petrochemicals One North Charles Street P.O. Box 1168 * Baltimore, Maryland 21203 * { 10} 3 -7 00 RO. Box 78 - Paw Creek; North Carolina 28130 h�� a.eae October 12 2001 Mr, Matt Mathews Aquatic Toxicology UnitOPT 1 6 2001 i Division of Water Quality Dept of Environment & Natural Resources 1621 email Service Center Raleigh, NC 27 99-1 21 WATER QUAIJ1,14H FET1101A Acute Toxicity Test April 2001 Dear Mr.lathews In response to your letter of August 20, 2001 grown has submitted a corrected Discharge Monitoring Deport to Central Files, A copy is attached for your reference. In order to preclude further problems with sample temperature control {gown will use a different laboratory in the future. Another test will be performed with the next discharge event which should occur during November. The issues you identified concerning the chain of custody will also be corrected when future acute toxicity tests are dune. Thank you for bringing these matters to Crown's attention, Sincerely, W. Floyd of c: John Lesley ooresville regional Office u Michael F. Easley Governor C j7 William G. Ross, Jr., Secretary Department of Environment and Natural Resources { Gregory J. Thorpe, Ph.D. Acting Director Division of Water Quality August 20, 2001 r. (John R. Funk Coordinator Regulatory Compliance & Training Crown Central Petroleum Corporation P.O. Box i Paw Creek, N.C. 28130 Subject: Toxicity Testing Protocol Paw Creek "Terminal NCO046531 Nlecklenb rg County Mr. Funk: On July 31, 2001 our office conducted a laboratory inspection at The ADVENT Group's laboratory. During that laboratory inspection, our office found that this lab conducted an acute tonicity test for Crown Central on 4/6/2001. Review of the chain -of -custody associated with this test revealed that the sample used in this acute tonicity test arrived at The ADVENT Group's lab in excess of 4.0 degrees Celsius. Protocol states that effluent samples should be received and maintained at 4.0 degrees Celsius until used in the. laboratory. This sample was less than 4.0 degrees Celsius when it arrived at Test America, however; when the sample arrived at The ADVENT Group(the bioassay lab) it was out of protocol. 'Therefore, we have invalidated the 4/612001 acute toxicity test. If ail LC50>100% was submitted on Crown Central's monthly monitoring report (DMR) for April, 2001, we remind you that the DMR submitted to the Division's Central Files must be amended. The effluent DMR facility information must be completely filled out (at the top of the sheet), and the form should have "CORRECTEDCOPY" written or typed at the top. The parameter code of your particular toxicity test should be re-entered in an appropriate column with a brief explanation that the test performed by The ADVENT Group was not suitable as performed. Our office will expectanother acute toxicity test to be performed during the next discharge event. One other issue that arose during this laboratory inspection that needs addressing; was the failure of the sample' collector to completely fill out the chain -of -custody. Please be reminded that your facility should be using the chain -of - custody from The ADVENT Group rather than 'Test America. AD NT's chain -of custody has been approved by our Unit. In addition, the chain -of -custody should be completely filled out. This includes' sample collection date,sample;' collection time and the signature of the collector: These were call missing for the416/2001 toxicity test. Should you have any questions regarding this letter, you are encouraged to call me or Kristie Robeson at (1) 733- 2136. Sincerely, 4 Matt Matthews, Supervisor Aquatic Toxicology unit cc: John Lesley -Mooresville Regional Office "Terri Horsley -The ADVENT Group, Inc. Test America ntral Files ebro Customer Service Environmental Sciences Branch 1621 Mail Service Center Raleigh, NC 7699-16 1 (919) 733-2136 1 8€ 0 6 -7748 ppl, F 0 c c m DI D P. R 41 yy 22 12 14 9 16 Viol, ac and Units 46W =7777T77777777777777=Mmm 22 29 is 30 "j- AVERAGE .042.SC, N rk 14 2!� '13 MEN HIN24UM sAft . . . . . . . . . . DEM Form MR"Ll (12/93) t3o 17 �e6cjpj6p Ira Facility Status: (Please check one of the following) r ------ I All monitoring data and sampling frequencies meet permit requirements LYJ Compliant All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant If the facility is noncompliant, please con ancrit on corrective actions being taken in respect to equipment, operation, maintenance, etc., and a time table for improvements to be made. NC Lc`-r t i L ti A wA 0-21, �1 rZ b�N� "I certify, under penalty of law, that this document mid all attachments were prepared raider my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person,or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Permittee, (Please print or type) �_L;F_ 0 - , ' -���D te� Signaturcot'Per itce�& A A3(1 1�3 f-b 0 j Permittw Address Phone Number 'Pernift Exp. Date PARAMETER CODES 00010 Temperature' 00556 Oil & Grease 00951 Total Fluoride 01067 Nickel 50060 Total 00076 Turbidity 00600 Total Nitrogen 01002 Total Arsenic 01077 Silver Residual 00080 Color (Pt -Co)' 00610 Ammonia Nitrogen 01092 Zinc Chlorine 00082 Color (ADMI) 00625 Total Kjeldhai 01027 Cadmium 01105 Alurninum Nitrogen 00095 Conductivity 00630 Nitrates/Nitrites 01032 Hexavaletit Chromium 01147 Total Selenium 71880 Formaldehyde 00300 Dissolved Oxygen 01034 Chromium 31616 Fecal Coliform 7,1900 Mercury 00310 BOD5 00665 Total Phosphorous 32730 Total Phenolics 81551 Xylene 00340 COD 00,720 Cyanide 01037 Total Cobalt 34235 Benzene 00400 pH 00745 Total Sulfide 01042 Copper 34481 Toluene 00530 Total Suspended 00927 Total Magnesium 38260 MBAS Residue, 00929 Total Sodium 01045 Iron 39516 PCBs 00545 Settleable Matter 00940 Total Chloride 01051 Lead 50050 Flow Parameter Code assistance may obtained by calling the Water Quality Compliance Group at (919) 733-5083, extension 581 or 534. The monthly average for fecal coliform is to be reported as a GEOMETRIC mean, Use only units designated in the reporting facility's permit for reporting data. ORC must visit facility and document visitation of facility as required per 15A NCAC 8A .0202 (b) (5) (B), If signed by other -than the permittee, delegation of signatory authority must be on file with the state per 15A NCAC 2B .0506 (b) (2) (D). 'mvironrnent and Natural Re our enrol System Operator Certification ,overnor Secretary NC DEI hairman AND N TR ' CERTIFIED MAIL August RETURN RECEELREQUESTED Mr. John Funk Crown Central Petroleum Corp PO Box 7 Paw Creek, NC 28130 WATER QUALITY SECTION System: Crown Central Petroleum Corp; Wastewater Treatment ,Systerr Classification: Grade I Physical Chemical System Subject: Designation of ORC and Backup ORC'for Physical / Chemica Permits NCOO4,6531 Dear Mr.. Punk: NCAC 8G .0306, Classification of Physical / Chemical Sy ster e physical / chemical systems. lassified as a Grade I Physical / Chemical' 8G .0306(a) shall also be classified as Grade H Physical / Chemical Water Pollution Control System. Rule 15A NCAC 8G .0306(b) If the water pollution control system that has, as part of its treatment process, biological water pollution control system that may be classified under Rule .0302, then that system shall b subject to additional classification as a biological water pollution control system. Rule 1 NCAC 8G .0306(e) Any water ;pollution control system subject to classification under Rule .0302 of this Section; utilizing a physical / chemical process to enhance an activated sludge or fixed growth process shall not be subject to additional class f3cation. Rule 15A NCAC 8G .0316(d) 1618 Mail Service Center, Raleigh, North Carolina 7699-1618 Phone: 91 — 733-0026 \ FAX: 919 - 73 -1338 AN EQUAL OPPORTUNITY l AFFIRMATTVE ACTION EMPLOYER — 50 RECYCLED / 10 o POST CONSUMER PAPER PP_ The Water Pollution Control your system as a Oracle I inforination submitted in yo information you provided in during the months of April-M ­­ i Operators Certification Commission herc d ChemiK#L5_Y_Ste m. This classification ur application for a NPDES permit —ar he physical chemical classification survey ay 2001. Responsible Charge (ORC) and back-up operator of the appropriate type must he designated for each classified system.Your stem re wires an C1RC and back-u overator who hold valid ohvsical / chemical overator certificates. Please complete and return the enclosed designation form to this office by December 31, 2003. Failure to designate a properly certified ORC and back-up operator is a violation of the permit issued for this system. In accordance with Rule 15A NCAC 8G .0406(b), individuals presently working at physical chemical water pollution control systems holding a valid Grade 1, 11, M, or IV wastewater treatment plant operator certification, may apply for a conditional operators physical / chentical certificate without examination. He or she may do so if, he or she has one year experience and has successfully completed a training school sponsored or co -sponsored by the Commission for Grade I or Grade 2 Physical / Chemical Water Pollution Control System Operators. This conditional certirication allows the bearer to act as the ORC or Backup ORC of that System only. This conditional certification must be renewed annually per section .0700 of the rules, The Rules for this certification as well as others is found on the DWQ/Technical Assistance and Certification Unit web page (http://h20.enr.state.nc.us/tacu/). Plans are now being made to conduct the first physical chemical school in January 15-18, 2002 at the McKimmon Center in Raleigh. This school is co -sponsored by AWWAIWEA and the NC Water Pollution Control System Operators Certification Conunission. As soon as arrangements for the school are finalized you will receive more information. If we can be of assistance or you have any questions concerning this requirement, please call Jarnes Pugh at 919-733-0026, ext. 341 or e-mail: James.Pugh@ncmail.net. Sincerely, Tony Arnold, Supervisor Technical Assistance and Certification Unit Enclosures cc: WSRO Central Files TAC Facility Files { �` \NAT Michael R Easley ( Governor William G. Ross, Jr., Secretary ~I Department of Environment and Natural Resources Gregory J. Thorpe, Ph.D, Acting Director Division of Water (duality August 20, 2001 fr. John R. Funk oordinator Regulatory Compliance & Training town Central Petroleum Corporation .0 Box 7 aw Creek, N.C. 28130 ub.ect: Toxicity Testing Protocol „, ti is s 8 a`"'W .'.a .,C Paw Creek Terminal t� a NCO046531 Mecklenburg County rlr. Funk: Can July 31, 2001 our office conducted a laboratory inspection at The ADVENT Group's laboratory. During that aboratory inspection, our office found that this lab conducted an acute toxicity test for Crown Central on 4/6/2001. review of the chain -of -custody associated with this test revealed that the sample used in this acute toxicity test arrived at Phe ADVENT Grc up's lab in excess of 4.0 degrees Celsius. Protocol states that effluent samples should be received and naintained at 4.0 degrees Celsius until used in the laboratory. This sample was less than 4.0 degrees Celsius when it rrrived atTest America, however, when the sample arrived at The ADVENT roup(the bioassay lab) it was out of )rctocol. Therefore, we have invalidatedthe 4/6/2001 acute toxicity test. If an L,C50> 100 is was submitted on grown Central's monthly monitoring report (DMR) for April, 2001, we •emind you that the DMR submitted to the Division's Central Files must be amended. The effluent DMR facility nformation must be completely filled out (at the top of the sheet), and the form should have "CORRECTED COPY" written or typed at the top: The parameter code of your particular toxicity test should be re-entered in an appropriate :olumn with a brief explanation that the test performed by The ADVENT Group was not suitable as performed. Our `office will expect another acute toxicity test to be performed during the next discharge event. One other issue that arose during this laboratory inspection that needs addressing was the failure of the sample collector to completely fill out the chain -of -custody, Please be reminded that your facility should be using the chain -of - custody from The ADVENT Group rather than Test America. ADVENT's chain -of custody has been approved by our Unit. In addition, the chain -of -custody should be completely filled out. This includes sample collection date, sample collection time and the signature of the collector'. These were all missing for the 4/6/21001 toxicity test. Should you have any questions regarding this letter, you are encouraged to call me or I ristie Robeson at (919) 733- 216. Sincerely, Matt Matthews, Supervisor Aquatic Toxicology Unit Terri Horsley -The ADVENT Group, Inc. Test America trl Files ustomer Service Environmental Sciences Branch 1621 Mail Service Center Raleigh, NC 276 6-162 (_ ) 73 216 800 -7 '48 0WA MichaoTE GON William G. Ross, JrSec > North Carolina Department of Environment and Natural Reso tD Kerr T. Stevens, of W Division of Water C April 26, 2001 Mr. Floyd Reid, Terminal Manager Crown Central Petroleum Corporation Post Office Box 78 Paw Creek, NC 28130 SUBJECT: Compliance Evaluation Inspection Crown Central Petroleum Corporation Charlotte Terminal NPDES Permit No. NCO046531 Mecklenburg County, NC Dear Mr. Reid: On April 12, 200 1, Mr, David Rimer of the Mecklenburg County Department of Environmental Protection conducted an inspection at the subject facility. This inspection was conducted as part of a cooperative working agreement between Mecklenburg County and the Division of Water Quality. The enclosed report should be self-explanatory. If you have any questions concerning this report or any other matters, please do not hesitate to call Mr. Richard Bridgeman or me at this Office. Sincerely, D. Rex Gleason, P. E. Water Quality Regional Supervisor Enclosure cc: Rusty Rozzelle, MC El' DJR i1c: WQ 0046531,401 N Customer Service Mooresville Regional Office, 919 North Main Street, Mooresville, NC 28115 PHONE (704) 663-161 1 800 623-7748 FAX (704) 663-60� US Environmental Protection Agency, Washington, D.C., 20460 OFF% AM orm Apro Fpvest. 0-005 OMB No.2047 I I Water Compliance Inspection Report i — Approval Expires 9-31-98 " NC Division of Water Qualityl Mooresville Regional Office as,adR 0 1 i Q on jCV Transaction Code NPDES No. Yr/Mo/Day Inspection Type Inspector Facility Type N 5 NCO046531 01/04/12 C C 2 Remarks: Inspector: Mecklenburg County Department of Environmental Protection Inspection Work Days Facility Evaluation Rating III QA . ........ Reserved- 0.5 3 N N Section R. Facility Date Name and Location of Facility Inspected* Entry Time: 03.00 pm Permit Effective Date: April 12,2001 September 1, 1996 Crown Central Petrolcurn Corporation Charlotte Terminal Exit Time/Date: 03:40 pin Permit Expiration Date: 7720 Mt. Holly Road April 12,2001 August 31, 2001 Mecklenburg County, North Carolina Name(s) of On -Site Representative(s)/Title(s)/Phone No(s)/Fax No(s): Mr. Floyd Reid Terminal Manager 704-392-2320 Name and Address of Responsible Official: Title. Terminal Manager Mr. Floyd Reid Crown Central Petroleum Corp. - Charlotte Terminal P.0, Box 78 Phone No: 704-392-2320 Contacted? Yes Paw Creek, N.C. 28130 --Aire'WEvaluated D-uring` ,Iospcction,,,('PO althose'areas evaluated V Permit V Flow Measurement V Operations & Maintenance Sewer Overflow s/ Records/Reports V Self -Monitoring Program Sludge Handling/Disposal Pollution Prevention V Facility Site Review Compliance Schedules Pretreatment Multimedia V Effluent/Receiving Waters V Laboratory Storm Water Other: Section D:, Summary of Findings/Comments See Attached Sheet(s) for Summary. All areas are rated satisfactory unless otherwise indicated. Ill I I I 1 11 Name(s) and Signature(s) of Inspectors: Agency/Office/Telephone No: Date: David Rimer MCDEP / Charlotte / (704) 336-5500 April 18,2001 Date: Signature of Management QA Reviewer: Agency/Office/Phone & Fax No: Date: I I I I I I EPA Form 3SW3 (Rev. 9-94) Previous editions are obsolete I GENE The facility was last inspected by MCDEP on June 7, 2000. A Compliance Evah Inspection teport was issued on June 21, 2000. PERMIT: The NPDES permit for the facility was modified in August 1998 and expires on rs adequate for the storm water and treated loading rack wastewater lei 'URT S: .-eadily available at the facility. Records, reports, and to no discrepancies were noted. SITE REVIEW: site is engaged in gasoline fuel oil storage d di tr log 11 • e le d well ibutioh. The NPI ES facility separator is returned to the premium gasoline storage (Tank # 1 ). The discharge halve for outfall 001 is kept closed and locked, except during discharge events. FLOW MEASUREMENT: Flow measurement is accomplished by calculating the volume of water in the spill control basin prior to discharge. This method is allowed by the permit. LABORATORY: Analysis of effluent samples is performed by Test America. TestAmerica is certified by the Mate of North Carolina to perform analysis on all parameters specified in the permit. Test America was not evaluated under this inspection. EFFLUENT/RECEIVING WATERS: The facility was not discharging at the time of the inspection. The facility discharges to an unnamed tributary to Gum Branch, which is a Class WS-IV water in the Catawba River Basin, via a riprap-lined ditch. SELF -MONITORING PROGRAM: DMRs were reviewed for the period March 2000 through February 2001. The reports indicate that the facility was meeting permit effluent limits during this period. Records indicate that all parameters are being monitored in accordance with permit requirements. OPERATIONS & MAINTENANCE: The facility and site appeared well operated and maintained. Storm water in the diked basins is visually inspected for the presence of petroleum sheen prior to discharge. - " CR N CHARLOTTE TERMINAL, ► , PLOT PLAN NORTH TANK l! `' o 2cry '' , t ITGO 00 SEP SOUTHr4 TANK FARM t%gaatcesr ii+ a�` t e tAt UVZ . ht�tatrt�• `` . v RESPONSE MAPS VDState of North Carolina .„ epartment of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor IL so William G. Rosa, Jr., Secretary Karr'T. Stevens, Director MCuENR NORTH CAROLINA 09AARTMEW OF February 26, 2001 ENVIRONMENT Ahab NATuRAL RESOURMS r. Floyd Reid Crown Central Petroleum Corporation PO Box 78 Paw Creek, North Carolina 28130 Subject. NPDES Permit Renewal Application �:. Permit NCO046531 Crown Central Petroleum Corporation Mecklenburg County Ue r,Mr. Beid: The.NPDES Unit received your permit renewal application on February 21, 2001. "Thank you for submitting this package. "The permit renewal for this facility will be assigned to a member of the NPDES Unit staff, That staff member will, contact you if further information is needed to complete the permit renewal, Please note that the NPDES Unit has several vacant positions;This staff shortage has lasted for over;a year and is delaying all permit renewals. Our remaining permit writers are currently reviewing Authorizations to Construct, speculative limit requests, major permit modifications and 201 plan updates ahead of permit renewals, This is Necessary due to a variety of factors, including mandatory deadlines in the statutes which govern our program, To facilitate permit renewal, the NPDES Unit is requesting that oil terminal bulk storage facilities submit a few additional items. As soon as possible, please submit the following items: • A site plan indicating all sources of stormwater, wastewater, and other wastewater (including any discharge from a groundwater remediation system) being discharged from the permitted outfall(s). • if available, a disk or electronic copy of the past five year's worth of discharge monitoring; report data from your facility. Microsoft Excel is the preferred format for such data. • A brief description of the manner in which tank solids, tank bottom water, the rag layer, and any other waters are disposed. If the staff shortage delays reissuance of NCC 046531 the existing requirements in your permit will remain in effect until the permit is renewed (or the Division takes other action). We appreciate your patience and understanding while we operate with a severely depleted staff., if you have any additional questions concerning renewal of the subject permit, please contact me at (19) 733- s083, extensions 520. Sincerely, alery Stephens Point Source thlit cc: Mooresville Regional Office Water Quality Section NPDES File \Jq A Michael Am"A 60 NCDENR William G. Ross, Jr., North Carolina Department of Environment and Natural F C) Kerr T. Stevens a January 29, 2001 NA `1'11kti�u, JOHN R. FUNK FFR Crown Central Petroleurn Corporation P0. Box 78 PAW CREEK, NC 28130 Subject: Renewal Notice NPDES Permit NCO046531 Pa­,,v Creek terminal Mecklenburg County Dear Permittee: The subject permit expires on August 31, 2001. North Carolina Administrative Code (I 5A NCAC 21-1.0105(e)) that an application for permit renewal be filed at least 180 days prior to expiration of the current permit. If you have alb mailed your renewal application, you may disregard this notice. Failure to request renewal of the permit by this date may result in a civil assessment of at least $500.00. Larger penalties may be assessed depending upon the delinquency of the request. If any wastewater discharge will occur after August 31, 2001 (or if continuation of the permit is desired), the current permit must be renewed. Discharge. of wastovater without a valid permit would violate North Carolina General Statute 143-215.1 and could result in assessment of civil penalties of up to $25,000 per day. If all wastewater discharge has ceased at your facility and you wish to rescind this permit, contact Bob Sledge of the Division's Compliance Enforcement Unit at (919) 733-5083, extension 547. You may also contact the Mooresville Regional Office at (704) 663-1699 to be& the rescission process. Use the enclosed checklist to complete your renewal package. The checklist identifies the items you must submit with the permit renewal application. If you have any questions, please contact me. My telephone number, fax number and e-mail address are fisted at the bottom of this page. Sincerely, Charles 14. \Xleaver, Jr. NPDES Unit cc,- Central Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 919 733.5083, extension 511 (fax) 919 733-0719 VISIT US ON THE INTERNET @ hftp*//h2o.enr.state.nc.us/NPDES e-mail: chades.weaver@nomail.net NPDES Permit NCO046531 Crown Central Petroleum Corporation Mecklenburg County The following items are REQUIRED for allrenewal packages: U A cover letter requesting renewal of the permit and documenting any changes at the facility, since issuance of the last permit. Submit one signed origin al and tN vo copies. U The completed application form (copy attached), signed by the permittee or an Authorized Representative, Submit one signed origjnal and two copies. U If an Authorized Representative (such as a consulting engineer or environmental consultant) prepares the renewal package, written documentation must be provided showing the authority delegated to any such Authorized Representative (see Part 11.13.11 b of the existing NPDES permit). U A narrative description of the sludge management plan for the facility. Describe how sludge or other solids) generated during wastewater treatment are handled and disposed. If your facility has no such plan (or the permitted facility, does not generate any solids), explain this in writing. Submit one signed original and two copies. f- 14 1 1 1 . I I — I � I . . I ­ . s -d1scharLYmLx t)rocess -o Title 40 of the, Code of 'PA) in accordance with 40 Jarcli 4, 2001, submit the ,t er March 4, 2001. ,idusaid faclUties. PLEASE NOTE: Due to a change in fees effective January 1, 1999, there is no renewal fee required with your application package, Send the completed renewal package to: Mr. Charles H. Weaver, Jr. NC DEN R / Water Quality / NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617