Loading...
HomeMy WebLinkAbout820576_Inspection_20201023Facility Number Division of Water Resources MGM 0 Division of Soil and Water Conservation, 0 Other Agency Type of Visit: p Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: is -23- 20 Arrival Time: i 00 Farm Name: J V v u,)1 fl e co - In c Owner Name: J IN Swine) (O Inc Departure Time: Mailing Address: Physical Address: Owner Email: Phone: County: Goy 11NO1 1 Region: fro Facility Contact: CU 1 g gO I V v 1 c t( Onsite Representative: S1 me Title: Phone: Certified Operator: rt.( l w 0 Otv h Back-up Operator: Location of Farm: Latitude: Integrator: Gm Certification Number: I (pi Le Certification Number: Longitude: Swine n A Design . Current ,Capacity Pop. Wean to Finish J Wean to Feeder Feeder to Finish Farrow to Wean ifpT9it I 2.1,9'i Farrow to Feeder Farrow to Finish Gilts Boars Other Other Design Current Wet Poultry Capacity Pop. Layer Non -Layer Design Current Ca ' aci Po Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? Cattle Design Current Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow ❑ Yes ❑NA ❑NE ❑ Yes ❑No ❑NA ❑NE ❑ Yes ❑No ❑NA ❑NE ❑ Yes ❑ Yes ❑ Yes Elio ❑NA ❑NE o ❑ NA ElNE kirNo ❑NA ❑NE Page 1 of 3 2/4/2015 Continued Facility Number: PI2- Cr- 0 Date of Inspection: ID .• 96 Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes ZNo ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 i-tu (,f li re 7 Identifier: Spillway?: Designed Freeboard (in): I1 19 I `I Observed Freeboard (in): J-3 5 y I7 3i 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? 31 I1 17 ❑ Yes 4Q No ❑ NA ❑ NE ❑ Yes [ 'No ❑ NA ❑ NE If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (not applicable to roofed pits, dry stacks, and/or wet stacks) ❑ Yes No ❑ NA ❑ Yes [/(No ❑ NA 9. Does any part of the waste management system other than the waste structures require ❑ Yes ✓�No ❑ NA maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes 10 ❑ NA ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ,1❑ Evidence of_ Wind Drift ❑ A(ovetgd plication Outside of Approved Area Cain 12. Crop Type(s): I wheal-15(Abecb j 1--mud Summer!k winter A- 13. Soil Type(s): v\IW,1 k U j GDP( • N V j 14. Do the receiving crops differ from those designated in the CAWMP? Yes ❑L�J N❑ NA El NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes �� o ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes ❑ No ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes © ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes No ❑ NA ❑ NE ❑ NE ❑ NE ❑ NE ❑ Yes "No ❑ NA ❑ NE ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes [.7'No ❑ NA ❑ NE the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑ Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. [ Yes E I4 ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield ,� 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections El Sludge Survey ❑ Yes DN$ ❑ NA ❑ NE 22. Did the facility fail to install and maintain a rain gauge? 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes No ❑ NA ❑ NE Page 2 of 3 2/4/2015 Continued Facility Number: - e`7 (p Date of Inspection: 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: El Yes No ❑NA ❑NE ❑ Yes No ❑ NA ❑ NE 26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes [No ❑ NA ❑ NE 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes [v]"No ❑ NA ❑ NE Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes ['No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes o ❑ NA ❑ NE If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes allo ❑ NA ❑ NE permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Yes E 1 o ❑ NA ❑ NE ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes [ No ❑ NA ❑ NE 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? ❑ Yes EiNo ❑ NA ❑ NE 34. Does the facility require a follow-up visit by the same agency? ❑ Yes L'J No ❑ NA ❑ NE • Comments (refer to question #): Explain any YES. answers and/or any additional recommendations or any other comments. Use drawings'of facility to better explain situations (use additional pages as necessary). ne,e do f-u i n i t-g l 120 (n i r i nsr-ec ionic for 1-ab H Keeping_ Note: Nip Pz ic high cis well qs ZN on some AeidS Reviewer/Inspector Name: Kq ffQ Pig b I -e1i oi Reviewer/Inspector Signature: Page 3 of 3 c -en Phone: %%D-30.—D1f Date: 10'd,�' O�V 2/4/2015