Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0042238_Final Permit_20210121
CD ,S Transmittal Date: January 13, 2021 Project Name: Enclave CDC Project: 11662 To: Tim Heim, P.E. Environmental Engineer — Asheville Regional Office Water Quality Regional Operations Section NCDEQ — Division of Water Resources 2090 U.S. 70 Highway Swannanoa, NC 28778-8211 Via: ® Mail ❑ Overnight 0 Hand Delivered Copies 1 1 1 Date 0 Pick up @ CDC Office Description ® Digital 1/13/2021 Cover Letter 1/13/2021 Check in the amount of $480.00 (to be hand delivered) 1/13/2021 24x36 Engineering Plans 1 1 1 1 1 1 1 1/13/2021 FTA 04-16 Fast Track Sewer Application 1/13/2021 Developer's Operational Agreement 1/13/2021 FTSE 04-16 Flow Tracking Acceptance Application 1/13/2021 Site Maps 1/13/2021 Sewer Generator Specifications 1/13/2021 MSD Sewer Allocations 1/13/2021 Certicate of Authority Ja Mailing Address: P.O. Box 5432, Asheville, NC 28813 168 Patton Avenue Asheville, NC 28801 52 Walnut Street — Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-452-4410 Fax: 828-456-5455 THIS DOCUMENT HAS A COLORED BACKGROUND AND igd1CROPRINTING_THE REVERSE SIDE INCLUDES AN ARTIFICIAL WATERMARK. Enclave Asheville, LLC 531 S Main Street, Suite 207 Greenville, SC 29501 Southern First Bank PO 6nx 17465 Greenville, SC 29606 67-301 532 1091 PAY NC DEQ DATE 12/3'2020 Refer trice *'"480 00 Four Hundred Eighty and 00'100******:r***********,.***********.,**********_****************************************,.******** DOLLARS TO THL ORDER. OF NC DEQ 271 West Jones Street Raleigh, NO 27603 ME r, o Enclave Aiheyille,ewer FAst Track Rpplicaiian Fee 11'0 109 Lii' 1:05 32080 L Li: 0000 s 2 5006 711' Enclave Asheville, LLC NC DEQ 12/3/2020 Date Type Reference Original Amt. Balance Due Discount Payment 12/3/2020 Bill Sewer FT 480.00 480.00 480.00 Check Amount 480.00 1091 SFB-Acct #0067 Enclave Asheville, Sewer Fast Track Application 480.00 Enclave Asheville, LLC 1091 NC DEQ 12/3/2020 Date Type Reference Original Amt, Balance Due Discount Payment 12/3/2020 Bill Sewer FT 480.00 480.00 480.00 Check Amount 480.00 SFB-Acct #0067 Enclave Asheville, Sewer Fast Track Application 480.00 VersaCheck Form 1000 Classic (C1/17) www,veraacheck.com cpc gleam; January 13th, 2021 Tim Heim, P.E. Environmental Engineer — Asheville Regional Office Water Quality Regional Operations Section NCDEQ — Division of Water Resources 2090 U.S. 70 Highway Swannanoa, NC 28778-8211 RE: Enclave Asheville CDC Project No.: 11662 Dear Tim Heim, On behalf of Enclave Asheville, LLC we are requesting your review and approval of fast track sewer system extension permit application package for the subject project. The proposed project consists of a connection to public gravity sewer with a proposed private force main system to serve; 211 multi -family residential units that will be leased, and other appurtenances located at 1010 Enclave Piney Ln. Please note that the combined flow allocation was for 94,800 gallons per day. This project is two phase and will not use the entire flow allocated. The proposed flow will serve 211 apartments with a design flow of 94,800 GPD for current and future phases. Please find enclosed the following items for your review and approval: • Check in the amount of $480.00 (to be hand delivered) • 24x36 Engineering Plans • FTA 04-16 Fast Track Sewer Application • Developer's Operational Agreement • FTSE 04-16 Flow Tracking Acceptance Application • Site Maps • Sewer Generator Specifications • NC Certificate of Authority • MSD Sewer Allocations Mailing Address: P.O. Box 5432, Asheville, NC 28813 168 Patton Avenue Asheville, NC 28801 52 Walnut Street — Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-452-4410 Fax: 828-456-5455 If you should have any questions or need any additional information during your review, please do not hesitate to call our office. Sincerely, Jason Foster, P.E. Civil Design Concepts, P.A. jfoster@cdcgo.com Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 02T A300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION INSTRUCTIONS FOR FORM: FTA 01-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria and that plans, spedfcations and supporting documents have been prepared in accordance with, NCAC 02T, 15A NCAC 02T .0300, Division policies and good euetneering mucticet While no upfront engineering design documents are required for submittal, in accordance with I5A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that require an environmental assessment in accordance with 15A NCAC 1C .0100; ➢ Projects that do not meet any part of the minimum design criteria (MDC) document ➢ Projects that involve a variance from the requirements of 15A NCAC 2T; ➢ Pressure sewer systems unlizing septic tack -effluent pumps (STEPS) or simplex grinder pumps; > STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); > Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result la return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or doe to space restrictions, attachments to the application may be made. • If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State, 0 If the Applicant Type in Item 12 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensedProfessional Engineer_ ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b1 Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner bas adequate capacity and will not violate G.S. 143- 215.67(a). ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. ➢ Location of the project (gravity sewer, pump stations & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would l lee the Division to address during the permit modification (Le., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): O Per 15A NCAC 02T .03051)hx1). submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows leas than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(6)) or proposed contractor, stating that "the portable power goon unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation ofthis pump station." ➢ If the portable power source or pomp is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of motion) L Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ® Per 15A NCAC 02T .0115(011 provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility francbise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOAIPOA and Developers for lots to be sold): ❑ I;DertY Owners' Associations ❑ Per 15A NCAC 02T .0115(cl. submit the properly executed Operational Agreement (FORM: HOAI. O Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ® Developers of lots to be sold El Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE ,APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Pak, Rutherford, Swain,Tranayivania, Yancey Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayefteville, North Carolina 28301-5094 (910) 433-3300 (910) 488-0707 Fax Anson, Biaden, Cumberland, Harnett, Holm, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 883-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Redid, Lincoln, Mecklenburg, Rowan, Stanly, Union Water Quality Section Jialelah RealonaLOfrlce 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgeoombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, 1Allson Water Quailbr Section Washlnoton Rational Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Berle, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water Quality Section )IYliminaton Regional Office Water Quality Section 127 Cardinal Drive Extension Wllmingt+on, North Carolina 28405 (910) 796-7215 (910) 350 2004 Fax - Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pander Winston-Salem Regional Office Water Quail&y Section 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolna 27105 (336) 776.9800 Alamance, Allegheny, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Roddngham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 Dhrlslon of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 do SUPPORTING DOCUMENTATION Application Number. (to be completed by DWR) L APPLICANT INFORMATION: 1. Applicant's name: )enclave Asheville. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ►=' Corporation ❑ General Partnership 0 Privately -Owned Public Utility 0 Federal 0 State/County 0 Municipal ❑ Other 3. Signature authority's name: Marcus McCall per 15A NCAC 02T .0106(b) Title: jig 4. Applicant's mailing address: 531 South Main Street. Ste 207 City: Greenville State: fic Zip: 5. Applicant's contact information: Phone number. (j§4) 370-0)37 Email Address: gmk(aimccailcap.com H. PROJECT INFORMATION: 1. Project name: Enclave Asheville 2. Application/Project status: ® Proposed (New Permit) 0 Existing Permit/Project If a modification, provide the existing permit number WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number WQ00 3. County where project is located: 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.5950° Longitude: -82.5253° 5. Parcel ID (if applicable): 9659-20-1099 (or Parcel ID to closest downstream sewer) IIL CONSULTANT INFORMATION: 1. Professional Engineer: Richard Jason Foster License Number 047671 Finn: ivil 'en Concepts. PA Mailing address: 168 Patton Avenue City: Asheville State: NC Zip: 21101-_ Phone number: ME $381 Email Address: jfottiacdspAnni IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Water Reclamation Facility Permit Number. NC0024911 Owner Name: MSD of Buncombe County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQCS00004 Downstream (Receiving) Sewer Size: $ inch $vstem Wide Collection System Permit Numberls) (if applicable): WQCS Owner Name(s): MSD of Buncombe County FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. Mille Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM• DEVI been attached? Yes ❑No ®NIA 3. If the Applicant is a Home/Property Owners' Association. has an Operational Agreement (FORM: HOM been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car wash ® Residential Leased 0 Retail with food preparation/service 0 Hotel and/or Motels ❑ School / preschool / day care 0 Medical / dental / veterinary facilities ® Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church. 0 Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 114 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(201) �Ia there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(0? ❑ Yes ®No > If yes. provide a cony of Row reduction approval letter 7. Summarize wastewater generated by project Establishment Type (see 02T.0114(11) Daily Design Flow 64 No. of Units Flow Residential 120 gal/day per bedroom 790 94,800 GPI) gal/ GPD gall GPD Pli OPD pi! GPD gall GPD Tatal 94,800 GPD a See 15A NCAC 02T .0114(bl. (d1. (call and (e)(21 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or eat of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using factures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project _ GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zoo, indicate why: 0 Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in PermitNumber: Z019075 and 2020085 ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2of5 VB. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers); 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 852 PVC 8 746 DIP 6 407 PVC 6 227 DIP > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pumo Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS_PROJECT 1. Pump station number or name: Enclave Asheville Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 3559° Longitude: -82.53° 3. Design flow of the pump station: „Ma millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): IN gallons per minute at 117 feet total dynamic head (TDH) 5. Summarize the force main to be permitted itted (for this Pump Station): She (Inches) Length (feet) Material 4 845 PVC 6. Power reliability in accordance with j5A NCAC Ji2T .0305(h411: ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(hx1)(B)_ > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(hx1XC) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(hx1XC): • It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. • If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(1)): 1. Does the project comply with all separations found m 15A NCAC 02T .0305(f1 & (g) ➢ 15A NCAC 02T.0305(fl contains minimum separations that shall be arovided for sewer systems: IN is Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 fed **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class ll impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 text Top slope of embankment or cuts of 2 fed or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications webvaae ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ►,4 N/A > See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required ifthe alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin Hiles per 15A NCAC 02B .0200? 0 Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch El Yes ® No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105fcj(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority? Per 15A NCAC 02T.0402. "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes El No ®NIA ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every sit -months and Inspections documented per i5A NCAC 02T.0403(aX5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pumo Stations and Force Mains (latest version). and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ®Yes No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Oporoval of the request is yeauired prior to sqllap(ttal of the Put Track Application and sunnortiae documents, 2. Professional Engineer's Certification: leef/PaS 's name from Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the beat of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143 215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: l% s. AL 1 7. =�: L04 6r 9 • r;a_ ( 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, i` Mt!.U.1 5_ 1 r l['.CCL.1I, r 3jdeit if r C'�"�� attest that this application for (Signature Authority s name & title &o�pplication' Ite L3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be reamed to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. FORM: FM 04-16 Page 5 of 5 DWR Division of Water Resources Entity Applicant Name: STEPHEN BEVERIDGE State of North Carolina Department of Environment Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE-04-16) Project Name for which flow is being requested: 2019075 - ENCLAVE AT PINEY MOUNTAIN -RENEWAL Afore than one 1TSE may be required for a single project lithe owner of the IJ1I'TP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Water Reclamation Facility b. WWTP Facility Permit.: NC0024911 c. WWTP facility's permitted Flow: d. Estimated obligated flow not yet tributary to WWTP: e. WWTP facility's actual avg flow: f. Total flow for this specific request: g. Total actual and obligated flows to the facility: h. Percent of permitted flow used: All flows are in MGD 40 9.3503 24.2433 0.0600 33.5936 84% I1. Complete this section for each pump station you are responsible for along the route of this proposed water flow. List pump stations located between the project connection point and the WWTP Pump Station (Name or Number) Firm Capacity.* MGD (A) (B) Design Approx. Current Avg. Average Daily Flow** (Firm / Daily Flow, ply MO I) MGD (C) Obligated, Not Yet Tributary Daily Flow, MOD (D)=(B+C) Total Current Flow Plus Obligated Flow * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not Tess than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <= 0. Downstream Facility Name (Sewer): Downstream Permit Number: 111. CertificationStatement: MSD of Buncombe County Collection System (E)=(A-D) Available Capacity *** WQCS00004 certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project as been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data . This artificeappli to those items listed above in Sections 1 and II plus all attached planning assessment addendums for which 1 am the responsible p iggning Ojjtci l Sign. re f this form i icates acceptance of this wastewater flow. Da Pave 1 of 1 FTSE 04-16 Metropolitan Sewerage District of Buncombe County, North Carolina Allocation Approval This approval is not to be used to obtain a building permit and is for gravity sewer extension only. Applicant: STEPHEN BEVERiDGE Reviewed ft Approved by: CHRIS FLAHERTY on 3/8/2019 Company: CIVIL DESIGN CONCEPTS, PA Mailing Address: 168 PATTON AVENUE, ASHEVILLE, NC 28801 Phone: 8282525388 (W) Project #: 2019075 Project Name: ENCLAVE AT PINEY MOUNTAIN -RENEWAL Project Location: PINEY MOUNTAIN DRIVE (85) PIN: 9659201099 MSD of Buncombe County has approved your request for 60,000 GPD The connection point (manhole #) will be 46-57065 The project will consist of (211) MULTI -FAMILY UNITS Your final approval is contingent upon compliance of the items below: - A PUBLIC GRAVITY SEWER EXTENSION I5 REQUIRED TO THE SUBJECT PROPERTY. Please submit plans for review and permitting. If you have questions please contact Kevin Johnson at (828)-225-8289. - Appropriate permissions from City of Asheville will be required for the public sewer line being constructed within the Piney Mountain Drive road right of way. - The on -site sewer system will be private permitted through NCDEQ. Please provide a copy of permit for private system prior to construction and issuance of building permits. Comments: In addition to the typical public sewer closeout requirements, MSD will also require a copy of the as-bu ilt drawing for the private sewer collection system including pump station and force main. kW will also require a copy of the engineer's certificate of completion required by NCDEQ. The North Carolina Department of Environmental Quality (NCDEQ) requires MSD to issue this approval based on line condition/capacity of the receiving sewer and remaining plant capacity. This allocation approval will expire on 03/08/2020 if no construction has started. If you have any questions, please contact MSD. MSD Planning and Development Approval Revised on 1 /12/2021 by Kevin Johnson Metropolitan Sewerage District of Buncombe County, North Carolina Allocation Approval This approval is not to be used to obtain a building permit and is for gravity sewer extension only. Applicant: Warren Sugg, P.E. Company: Civil Design Concepts, PA Mailing Address: 168 Patton Avenue, Asheville, NC 28801 Phone: 828-252-5388 (H) Project #: 2020085 Project Name: Enclave - Phase II Project Location: Piney Mountain Rd PIN: 9658292204 MSD of Buncombe County has approved your request for 34,800 GPD The connection point (manhole #) will be Private Pump Station The project will consist of (116) 3 bed/2 bath Your final approval is contingent upon compliance of the items below: - This project will require a private sewer extension permit from NC DEQ. MSD will require a copy of this permit prior to release of building permits. MSD also requires a copy of engineer's certificate of completion required by NCDEQ along with a copy of private system as -built prior to release of certificates of occupancy. Please contact Kevin Johnson at MSD for additional requirements for this project at (828)-254-9646. - This phase of the system will connect to the private system permitted and constructed for Phase 1 under the conditions required. Please complete sewer service application(s) after issuance of private system permit and MSD staff will contact you about applicable fees. Comments: * Please note that this phase of the project is only being approved on the condition that this parcel be combined with the phase 1 parcel_ MSD will only allow private systems for single parcels. " Please note that MSD will only allow the private system if a public gravity sewer is extended to the Phase 1 property line. The North Carolina Department of Environmental Quality (NCDEQ) requires MSD to issue this approval based on line condition/capacity of the receiving sewer and remaining plant capacity. This allocation approval will expire on 07/13/2021 if no construction has started. w�, , If you have any questions, please contact MSD. Kevin Johnson MSD Planning and Development A— Q 0 CO 0 'CD o c m 0-o c 0 is 0 0 U o ez �Z m 4 m c 8'm 0 ° 0� -E co &c� Ew m _ Q a) .0 al— 0. t co c E `o we m c • °°E4 O E ▪ ;cre 1O a E c ,0 c ••- mono W 0 0- 0 c 0 r$ as • c o c E oXa30 mF G 4.2c 0 a) .m C 0. a) ac 0)10cc y .py c om� w & o O 31 0 0 m ▪ •Co R s oc u m o 0) .e .S1▪ 1.E y gi g o - w •2 c o. LL o E mri cog �m -o ▪ 0 kl m C. • a0 c 2 • 0 �t,E ✓ wQ�40 z '� tf o$E c.)o-oo¢ 0)m )c.c C7 00al m... c • m a C is CO _,0 e E e c V • c d 5 3 e mZ 0_ E �e coi3Edi C my i m rr,3.o o v'm8°u Q x� m m 0 o a) v U ❑r 0 c Vi C d N 7 .S 'o,4 CO STATE OF NORTH CAROLINA COUNTY OF Buncombe Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (d1) and entered into this day by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMNIISSION; and Enclave Asheville. LLC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: of 1. The DEVELOPER is the owner of the certain lands lying in Buncombe County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as Enclave Asheville (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the (Enter Proposed Unit Owners' Association) (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. 1 r )xx. TVA 7 A"t/A* Din ..., 1 ,. 7 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the conunon expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL Enclave Asheville. LLC MANAGEMENT COMMISSION Coleen IL Sullins, Director Division of Water Quality Name DEVELOPER ii(j4e4,. Me. I, 'Plane er Print Name and Title /3 00/ (Date) (D ) 'Eva, A s. TUN r mint NORTH CAROLINA Department of the Secretary of State CERTIFICATE OF EXISTENCE (Limited Liability Company) I, Elaine F. Marshall, Secretary of State of the State of North Carolina, do hereby certify that ENCLAVE ASHEVILLE, LLC is a limited liability company duly formed, and existing under the laws of the State of North Carolina, having been formed on 23rd day of March, 2017 I FURTHER certify that, as of the date of this certificate, (i) the said limited liability company is not dissolved under the terms of its articles of organization, (ii) the said limited liability company's articles of organization are not suspended for failure to comply with the Revenue Act of the State of North Carolina, (iii) that said limited liability company is not administratively dissolved for failure to comply with the provisions of the North Carolina Limited Liability Company Act, (iv) that this office has not filed any decree of judicial dissolution, articles of dissolution, articles of merger, or articles of conversion for said limited liability company. Scan to verify online. Certification 108290602-1 Reference# 16559300- Page: 1 of 1 Verify this certificate online at https://www.sosnc_gov/verification IN WITNESS WHEREOF', I have hereunto set my hand and affixed my official seal at the City of Raleigh, this 7th day of October, 2020. "404, J Iotalaze Secretary of State NORTH CAROLINA Department of the Secretary of State To all whom these presents shall come, Greetings: I, Elaine F. Marshall, Secretary of State of the State of North Carolina, do hereby certify the following and hereto attached to be a true copy of ARTICLES OF ORGANIZATION OF ENCLAVE ASHEVILLE, LLC the original of which was filed in this office on the 20th day of March, 2017. Scan to verify online. IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal at the City of Raleigh, this 23rd day of March, 2017. "low, J Imaale Certification# C201707904834-1 Reference# C201707904834-1 Page: 1 of 3 Verify this certificate online at http://www.sosnc.gov/verification Secretary of State State of North Carolina Department of the Secretary of State Limited Liability Company ARTICLES OF ORGANIZATION SOSID: 1583155 Date Filed: 3/20/2017 11:55:00 AM Elaine F. Marshall North Carolina Secretary of State C2017 079 04834 Pursuant to §57D-2-20 of the General Statutes of North Carolina, the undersigned does hereby submit these Articles of Organization for the purpose of forming a limited liability company. 1. The name of the limited Iiability company is: Enclave Asheville, LLC (See Item lof the Instructions for appropriate entity designation) 2. The name and address of each person executing these articles of organization is as follows: (State whether each person is executing these articles of organization in the capacity of a member, organizer or both. Note: This document must be signed by all persons listed.) Name Address Capacity Marcus S. McCall 531 S. Main Street, Suite 207 Organizer Greenville, SC 29602 3. The name of the initial registered agent is: Parker Poe Adams & Bernstein 4. The street address and county of the initial registered agent office of the limited liability company is: Number and Street 401 South Tryon Street, Suite 3000 City Charlotte State: NC Zip Code: 28202 County: Mecklenburg 5. The mailing address, if different from the street address, of the initial registered agent office is: Number and Street Same City State: NC Zip Code: County: 6. Principal office information: (Select either a or b.) a. 0 The limited liability company has a principal office. 864-370-0037 The principal office telephone number: The street address and county of the principal office of the limited liability company is: Number and Street: 531 S. Main Street, Suite 207 Greenville SC 29602 Greenville City: State: Zip Code: _ County: CORPORATIONS DIVISION (Revised December 2016) P.O. Box 29622 2 RALEIGH, NC 27626-0622 (Form L-0!) Certification# C201707904834-1 Reference# C201707904834- Page: 2 of 3 The mailingaddress, if different from the street address, of the principal office of the company is: Number and Street: Same City: State: Zip Code: County: b. ❑ The limited liability company does not have a principal office. 7. Any other provisions which the limited liability company elects to include (e.g,, the purpose of the entity) are attached. 8. (Optional): Listing of Company Officials (See instructions on the importance of listing the company officials in the creation document. Name Title Business Address McCall Capital, LLC Manager 531 S. Main Street, Suite 207, Greenville, SC 29602 9. (Optional): Please provide a business e-mail address. rr Privacy Redaction The Secretary of State's Office will e-mail the business automatically at the address provided above at no cost when a document is filed. The e-mail provided will not be viewable on the website. For more information on why this service is offered, please see the instructions for this document. I0. These articles will be effective upon filing, unless a future date is specified: Upon Filing March This is the 6a d'ay of ) 20 17• Enclave Asheville, LLC Signature Marcus S. McCaII, Organizer Type or Print Name and Title The below space to be used if more than one organizer or member is listed in Item #2 above. Signature Signature Type and Print Name and Title Type and Print Name and Title NOTE: 1. Filing fee is $125. This document must be filed with the Secretary of State. CORPORATIONS DIVISION (Revised December 2016) P.O. Box 29622 3 RALEIGH, NC 27626-0622 (Form L-01) Certification# C201707904834-1 Reference# C201707904834- Page: 3 of 3 GRUNDFOS Grundfos Series SLV Sewage Pump with SuperVortex Impeller SUBMITTAL PROJECT NUMBER ! ID 1143345 REPRESENTATIVE ENGINEER CONTRACTOR UNIT TAG Submersible Wastewater QUANTITY 2 Pumps SERVICE Municipal DATE SUBMITTED BY DATE APPROVED BY DATE ORDER # SLV.30.A40.150.EX.2.61 R.0 Part 99030275 Number 3539 rpm Conditions of Service Pump Data Motor Data Flow 170.0 USgpm Impeller Diameter 6.85 in Motor HP 15 HP Head 80.00 ft Cooling Jacket NO BHP 12.91 Liquid Cold Water Max Solid Size 3.15 Enclosure Explosion Proof Temperature 68.00 deg F Efficiency 32.27 % Voltage 460 V NPSHr 8.76 ft Suction 6 in. Phase 3 Phase Viscosity 1.00 cP Discharge 3.93700787401575 Cycle 60 Specific Gravity 1.000 5G in. 150 135 120 105 90 75 2 60 45 30 15 0 in 0 30 = 15 19 6.85 in `4 29 32 33 34 34 33 32 29 24 �15.0hp 0 50 100 150 200 250 300 Flow - USgpm 350 400 450 500 550 GRUNDFOS;< GRUN©FOS N Grundfos Quotation System 20.0.5 Pump Performance Datasheet i. uswomer Customer ref. / PO Tag Number Service Quantity tnaave Ashewhe : Submersible Wastewater Pumps : Municipal :2 per. ting Flow, rated Differential head / pressure, rated (requested) Differential head / pressure, rated (actual) Suction pressure, rated / max NPSH available, rated : 170.0 USgpm : 80.00 ft : 97.07 ft : 0.00 / 0.00 psi.g : Ample Frequency : 60 Hz Speed, rated a 3539 rpm Efficiency 1 32,27 % NPSH required / margin required 1 8.76 / 0.00 ft nq (imp. eye flow) / S (imp. eye flow) MCSF Head, maximum, rated diameter Head rise to shutoff Flow, best eff. point Flow ratio, rated 1 BEP Diameter ratio (rated / max) Head ratio (rated dia / max dia) Solids diameter limit Cq/Ch/Ce/Cn [ANSI/H19.6,7-2010] Selection status Curve Tolerance Consult Factory for a different Tolerance 40 / 164 Metric units 128,8ft ; 32.72 % 232.2 USgpm 73.22 % : 100.00 % • 100.00 % : 3.15 in : 1.00 / 1.00 / 1,00 / 1.00 : Near miss ANSI/H111.6:2012 3B Project Number 1 ID Model Stages Based on curve number Date last saved Liquid type Additional liquid description Solids diameter, max 1143345 SLV.30.A40.150 1 RC10639 : 03/31/2020 2:12 PM Cold Water : 0.00 in Temperature, max : 68,00 deg F Fluid density, rated / max ; 1.000 / 1.000 SG x.num wa ij pressure : 55,75 psi.g Motor sizing specification : Max power (non -overloading) Service factor Power, hydraulic Rated power (based an duty point) Max power (non -overloading) Nameplate motor rating Efficiency at 100% Efficiency at 75% Efficiency at 50% Power Factor at 100% Power Factor at 75% Power Factor at 50% : 1.00 : 4.17 hp : 12.91 hp : 15.66 hp : 15.00 hp / 11.19 kW (Fixed) : 90.7 :91.2 : 91.2 0.87 : 0.84 0.77 17) aS a) 150 135 720 105 90 75 60 45 30 15 0 30 15 200 250 300 Flow - USgpm 350 400 450 500 550 Carolina Pumpworks, LLC • 1703 Richmond Avenue • Port Royal, SC 29935 phone: 843-522-9200 • fax: 843-522-9615 GRUNDFOSit Grundfos Quotation System 20.0.5 Pump Performance - Additional Data Project name Consulting engineer Customer Customer ref. / PO Project Number / ID Date last saved Stages : Enclave Asheville : Civil Design Concepts, PLLC : Enclave Asheville :1143345 : 03/31/2020 2:12 PM : 1 Bead, maximum dtameaer, rated flow Head, maximum. rated diameter Efficaeexy adjustrnern factor, total Torque, rated power, rated speed : 97,07 n :178.0fl : 1.00 : 0.36 hp/100 rpm itutecigPerforml Shutoff, rated diameter MCSF . Tk 0.00 Tag Number Service Model Quantity Quoted By (Sales Office) Quoted By (Sales Engineer) Speed, rated . Submersible Wastewater Pumps Municipal SLV.30.A40.150 2 : CAROLINA PUMPWORKS, LLC : Scott Hale : 2539 rpm Stage, Speed and Solids Limits Stages, maximum Pump speed limit, maximum Pump speed limit, minimum Curve speed limit, maximum Curve speed limit, minimum Solids diameter limit Typical {7riuzr Data Driver speed, full load Driver speed, rated load Driver efficiency, 100% load Driver efficiency, 75% load : 3548 rpm : 1800 rpm : 3548 rpm : 1800 rpm :3.15in : 3525 rpm : 3535 rpm : 90.20 % : 89.90 % Driver efficiency, 50% load : 88.30 % 128.8 - 10.35 Rated flow, maximum diameter 170.0 97.07 32.27 12.91 BEP flow, rated diameter 120% rated flow, rated diameter 232.2 204.0 78.85 87.29 34.40 33.98 11.80 10.30 13.43 13.23 End of curve, rated diameter Maximum value, rated diameter 497.5 differential p[«-r4lee Differential pressure, rated flow, rated diameter ps4 Differentia; pressure, shutoff, rated diameu~r (ps'1 re. 0i,5chatge pressure, rated !low, rated th me Er Ipst. i Disc ['wipe pressure, shuloV, ialed diameter Maximum flood 1 rated flow, rated diameter Motor Phase & Voltage 25.40 128.8 ? Oefrsily.:ate 4201 55.75 �.. Suction pressure, rated 20.37 34.40 SrictioI pressure, rnix 25.46 •45. D nSity.'fex' xi3' Suelion Pressure, rated 4101 55.75 15.66 15.66 .Sucla[un pressure,/flax 42.01 47,01 42,01 42.01 55.75 55.75 55.75 55,75 Rdtios 292, Gil % Head rated diairtietar / Head rrardmum diameter, rated flow 100.00 % c7• u ti n : Explosion Proof -STD Option, Best Lead time : 61 R-Three Phase, 230/460 V, 460 V Connected, Direct online start Sensor Installation Without Water In Oil Sensor Auto Coupling Carolina Pumpworks, LLC 1703 Richmond Avenue Port Royal, SC 29935 phone:843-522-9200 fax: 843-522-9615 GRUNDFOS Grundfos Series SLV Sewage Pump with SuperVortex Impeller SUBMITTAL PROJECT NUMBER / ID 1193345 UNIT TAG Submersible Wastewater SLV.30.A40.150.EX.2.61R.0 Pumps MATERIALS OF CONSTRUCTION PART MATERIAL PART MATERIAL Pump housing Cast Iron EN-G1L-250 Shaft seal Stalnles steel, SIC/ SIC Carbon/ceramic SuperVortex impeller Cast Iron EN-GJL-250 Oil Chamber Cast Iron EN-GJL-250 Clamp Cast Iron EN-GJL-250 Cover for oil chamber Cast Iron EN-GJL-250 Lifting bracket Stainless Steel 0-Rings NBR Rubber Shaft with rotor Regular iron/stainless steel :ey Stainless Steel Bearing Cover Cast Iron EN-GJL-250 * All materials based on STANDARD configuration GRUNDFOS Grundfos Quotation System 20.0.5 Construction Datasheet Project name Consulting engineer Customer Customer ref. / PO Quote Number / ID Date last saved Enclave Asheville Civil Design Concepts, PLLC Enclave Asheville 1143345 03/31/2020 2:12 PM Tag Number Service Model Quantity Quoted By (Sales Office) Quoted By (Sales Engineer) Submersible Wastewater Pumps Municipal SLV.30.A40.150 2 CAROLINA PUMPWORKS, LLC Scott Hale Construction Code : SLV.30.A40.150.EX.2.61 R.0 Product Family Product Type Pump Housing Type Pump Housing Material Impeller Type Impeller Material Primary Shaft Seal Material Secondary Shaft Seal Material Max Flow Max Head Suction Discharge Connection Solids Diameter Limit Coaling Jacket Pressure Stage Moisture Sensor Water in Oil Sensor Nameplate Approval Installation Orientation Max Installation Depth SL SLV Cast iron ASTM A48 3513 Super Vortex ASTM A48 35B SIC/SIC CARBON/CERAMICS 493.1 USgpm 126.3 ft 3" / DN80 4"IDN100 ANSI 3.15 in NO Class 125 YES NO CSA, FM SUBMERGED Vertical 65.62 ft Horsepower Enclosure Class Explosion proof Explosion Proof Class Frame Range Rated Voltage Rated Speed Phase Frequency Number of Poles Insulation Class Motor Thermal Protection Rated Current FLA LRA Efficiency at 100% Efficiency at 75% Efficiency at 50% Power Factor at 100% Power Factor at 75% Power Factor at 50% Start Method Max Starts per hour Cable Length Net Weight (Ib) fita 15,00 hp IP68 YES Class I, Division 1, Groups C and D, T4,T3C D 230/460 V 3530 rpm 3 60 Hz 2 H THERMAL SWITCH 37/20 A 37/20A 120/80A 90.7 91.2 91.2 0.87 0.84 0.77 Direct -on-line 20 49.21 ft 392.4 Ib Carolina Pumpworks, LLC • 1703 Richmond Avenue • Port Royal, SC 29935 phone: 843-522-9200 • fax: 843-522-9615 SLV.3D.A40.150.EX.2.61 R.0 UNIT TAG Submersible Wastewater Pumps PROJECT NUMBER ! ID 1143345 0 a Z C rang meat Tag Number Submersioie Wastewater Pumps Service : Municipal Model : SLV.30.A40.150.EX.2.61R.0 Quantity of pumps : 2 Quoted By (Sales Office) : CAROLINA PUMPWORKS, LLC Quoted By (Sales Engineer) : Scott Hale ZDN1 I ZM 0 E ?i Q 2 O Efficiency: 90.7 L 'J'S cp N in b m a Voltage: 230/460 SLZ 0 1 m 4c N 74 4.60 L LZ g Li M LLZ NIZLZ py o Ale glib . _o N N A A Rr=t ed and references CO co d C W o N 2 as — CO N 20.50 4.30 raliallm^fir P. a} o N N � ? �— NN` 6IIS u t General Ar Project name : Enclave Asheville Consulting engineer : Civil Design Concepts, PLLC Customer : CAROLINA PUMPWORKS, LLC Customer ref. / PO Quote Number / ID : 1143345 Date last saved : 03/3112020 2:12 PM 90 LZ c LZ 28.20 N i- 2 RPM: 3539 rpm CD r.] 0 t- 1r M N O a Conditions of Service Q7 00 'p C V :o M LL Temp.: 20.00 deg F EZ 4.30 N N 10.30 L_ O M• 0 r E 0 a r r- l TDH: 80.00 ft U o at •N Units H t u .cLI NO COMPROMISE UNMATCHED RELIABILITY AND EFFICIENCY he think i rinovale G !II N L RANGE I FL H P. Z, F. 01. GRUNDFOS V....8stelAirater pumps coriqpiries oprticiml ty vv h higr tptai efficiency ..,inTJ 011-....N you t 11..-Ant fr.jsL nl civim=irship • Thi: optimized hydrpulic design GITi.:!1.5 h igh L'l bgera 'Lona I 1 I i • 1.7110FR:iiir-P•fili.ierit polforr0 large srrieria I • pziss..agi remain ii29ccomiii-ornised • Still with the highest viiir'e.-to-viiyi.te'r MTh' ica • cLrrentlVavIewEth no compromise between r1LI11.w2shecI free pzcssJge 11. r'.111 0:74 k y.1)47.0 • - t-kt- HIGHEST EFFICIENCY OVER A WIDER RANGE [mL 90 — 80 — 70 — 60- 50 — 40- 30 — 20— [ft] 300 200 1S0 100 I0 30 , /0 %ice,,;,.. %%%",..:///f, �i/r.,„. ,,,,,./f,ff, 7,4,77 /0777 ,,,,,,,,,,,, .7,4 4,/ /c/,.,, 100 150 200 300 400 500 600 800 1000 1500 Q [US GPM] I •1 I .I I 40 50 60 '70 . Q [i/s] Performance range of the SL pump program For more product information please visit grundfos.us DESIGNED WITH STATE-OF-THE*ART HYDRAULICS When we designed new hydraulics specifically for pumping wastewater, we looked at the technologies available on the market and decided that we had to keep things simple. We were not just chasing the highest efficiency at a specific duty point, Wastewater pumps always run with varying loads, and we wanted our new hydraulics to have extremely high efficiency over a wider range of the curve, without compromising free passage and reliability. The S TUBE• impeller developed by Grundfos includes a tube - shaped impeller and a pump housing around it that matches the tube shape through the entire pump. This hydraulic solution contributes to make the 5L ranges the most innovative, efficient and robust wastewater pumps available today. The S-TUBE° impeller is wet -balanced. This lowers the vibration level dramatically. Highest efficiency and outstanding reliability When you experience the S TUBE°, you get the highest efficiency over a wider performance range and the largest free passage. We have created an impeller that is quite simply the best at fulfilling the core function for which a wastewater impeller is designed: providing the user with robust, efficient and trouble -free operation, and outstanding reliability. THE BEST TOTAL WIRE -TO -WATER EFFICIENCY Although the pump system may not be the largest single investment in the wastewater installation, over the installation's lifetime, it is the component in the system that is the key element to ensuring the long-term cost effectiveness of the wastewater installation. Therefore, it is important that we and our customers have a common understanding when we talk efficiencies. When we say total efficiency, we mean the total, wire -to - water efficiency. In a wastewater pump there will be electrical, mechanical and hydraulic losses. A pump manufacturer needs to master these without compromising reliability. At Grundfos, we do precisely this and can therefore supply high -efficiency products. We have listened to and understood your concerns with the costs incurred for inefficient operation, maintenance and downtime. All 5Lwastewater pumps are built with high -efficiency motors using IEC, 1E3 and NEMA premium efficiency motor components, and to this we add the innovative and elegant S TUBE®. impeller and intelligent controls. What you get are wastewater pumping solutions with the best performance and highest level of reliability currently available. 3 Designed for the most demanding applications and tested to the highest standards T1i€ h V `6 r51''1 '1'I''1.0.; I.;:, r'•�+' Iri your ;4•:,*,Pn' la t0 r7}II' •}} _ isI'I!:!1: I. • ''C•:.k fur 5ULIITE!,ged In`_..i 3t4v1is �1 .• 3 " n I . I C : r.--Y.} I ', ' r, , 1-. r Ies .I LI-:-. scin.h.rfiurijZital '. - .!.•iI-ni1 r16rr sI'C ti"1n�C�'1l�Ji?r .1(:11F1 ` dnlj 51,1r I :•41' L•;rrt+'r, d r;5t F•rcce r .-r Thr_y•;1•.d 4V�5+2'g1a+2r tr,rr.�poT#ati�r i1c r1'�r, ';'r .1 Ili',. InrJ'J -1rlal .arse iKSR}n, rci Iapp1i.siil'n ,ail.!.i''_',1_iirfurrGpv'.•r-.r4; i In1f Ind {[3t1 ;1{ arid 'rydkrnent plants The SL range= of astewritc!r..p1m; S:47.3 l I''r' :i3KtalIE 1 uSir! i11 'il '':•_ .::' '''9 p1.14C-ra•:..ySt[~ITr Csr :r ; l a i-�S t Fr, • ? dre JtIIItjrpulrps, 1 lie!E product:.'haYr a'small fo6tpFiliE on yr Ilrr'kiyjiri I.s•*3t3II:ItInn-'E3y this: 4V35`.A_1eVat.E! `JmpSw.th.T'.2w:5 OUra3I15 Ju11Ili:Lk! I...9'nni 4'+-' II. 11i.te7i' nr.; L: 11.{r. =nr- h7^4.ititz .;I I.irli.. Prlt:=r,L4' p'1 A'!4iC'J} s•d1- Or1 .-,rE ir-nrlrt_ , i<l:^11..• yuu wjLh mll}Irra rrF estme'1`t- I : ii1 IE1'r 'w Lli'I' 'ir,'i ru• r- ' • Cilu11'JF.%, ' s. I''ialul''I, ;I" t'1111. Ill.,' • i ... "'• •--4.1 _-�rnpv'IEnT� 4 r 4 4 ,I 11,11 1 I Ili' r .. ;;-'- L� • • N. 4-14 ryti ..`a r+ ' i-1• 1 I I Choice of impeller The 5 TUBE° impeller ensures no Compromise between the highest efficiency over a wider performance range, and the largest free passage. Greater free passage means better solids handling and greater non -clogging abilities. All S-TUBE° impellers are wet -balanced to obtain a low vibration level. With the introduction of the two -channel S TUBE° design for larger capacities, the vibration level is further reduced. The S TUBE° impeller is a'vaneless' closed channel - impeller design without leading edges that prevents clogging in the impeller. Athreaded sealing system offers effective and robust sealing between the impeller and volute. Large spherical passage - SL pumps fitted with S-TUBE° Mk2 hydraulic design Heavy-duty cast iron, one -channel closed 5 TUBE° Mk2 impeller design with 2", 3" or 4" free spherical . passage optimizes hydraulic efficiency and reduces energy costs. Industry -leading product development At Grundfos, we have decades of experience using simulations and testing to optimize pump reliability and efficiency, while ensuring a quality product design that matches the customer's application requirements. Extensive field testing is carried out before a new product range is released to the market. Higher dry solids content — SL pumps fitted with SuperVortex For applications with intermittent operation and where dry solids content is owr 3 %, the SuperVortex impeller with spherical free passage up to 4 inches is ideal. By combining test-driven and simulation -driven development, we have increased our capacity to build engineered -to -order products, tailored to specific customer requirements. Grundfos smart design provides reliability and efficiency for your wastewater pumping system A r'undfo.s, vie, have e tensive experi fc arjapttng i nd rrnpr4 viflg.the durabil:ly and obit-xa ionre1i.hiIity of our Vvacteeater pumps. For 75.ytars, h-ve `)E I a.pplyiIrg pump design, testing ind tef=hnology to meet the requirements. of the:enti:e iody..3 Ler cycle. Thai why Grundfos js uniquely po s t:onecd to a brcr dly applic.p e wastewater porn p and stay one ste.p.ahead of 1I.ih constantly changing dem.9nLs d.# al.water today. 6 Double mechanical shaft seal Primary and secondary seal in one cartridge unit providing longer seal lifetime and easy fail -proof replacement— even in the field. Replacement can be done without special tools. Short rotor shaft Compact motor construction reduces vibrations to protect shaft seals and bearings, ensuring a longer operational lifetime with less maintenance. Easy -to -remove cable entry The innovative and patented stainless steel cable entry ensures that liquid cannot penetrate through the cable inlet into the motor and is easy to dismantle in case of service. One cable to the pump With just one cable to connectsensors and power supply, an important at -risk area is removed, simplifying pump installation, commissioning and maintenance. Easy -to -open clamp The stainless steel clamp assembly system requires no tools for the quick and easy disassembly of pump from motor unit, and offers easy access for pump maintenance. Patented SmartSeal The patented Grundfos 5mart5eal auto - coupling gasket provides a completely leak- proof connection between the pump and the base unit ofthe auto -coupling system. lifting handle The lifting handle is designed for optimum point -of -balance, ensuring correct lifting and protecting the auto -coupling sealing. Smooth, easy -to -clean surface The extremely robust impact.resistant surface is smooth and easily cleaned. Hydraulic design Hydraulics have been upgraded with improved fiber handling, enhaced wear resistance on the sealing system and energy -efficient performance. he think innovate WE ARE iri4 THE driVATER.E!USICIESS W111-I YQ1.1 05.5 a pioneer. ari ibi eader in ...water puny .technology, Ccuridlos creates Intelligent •sustainaltile solutions ie help soNe rthe world's water •and climate challenges. Through our lie!li iig.wEtIve the exp.erience and innovative capabilities to tielp our partners, ctistomers and communities move water in:an triCrearAngty energy and water efficient mannEr. WE Se E this BS rot oniy A great business tipportwilty, but as ;Nil obligation to ensure the wockli heads• toward .3 more $List airo tomorrow. 0.ur Compete portiolto oF pumps and •so kut ions are idesrgned fOr CO.P11.11101CLar, groundwater, munittpal an,cf iitIapplications with erriphas.isri trencts..etting., energy efficient teclinorogies .such BE. permanent ma.gnet motors aocl advanced pump controls. and monitoring. Because water mat ter's, nd w doe s. yo tic busInts S. To hearrirnott". Visit run dio5.us or folkavv Li 5 Cin ru'rebool.: and Linkedln. I !pi ' !Ilia' r 1..i. r • • I 1: I I • '; 7171.7:c !NH .rqiir.I.Pnr,r1., Ind rTF 13 i I.rI On ..-1...Tro.j.rnacliE Inc rnerici;s rx 77423 VireilIvEr111' 7.1 15 F.1111. Lt:!.3 r. fo TNO GRUINEIFOS At% 4UA10 4UA13 KOHLER. Model: 200REZXB 208-600 V Gas 0 9007 KoHLER. NATIONALLY REGISTERED EPA -Certified for Stationary and Mobile Emergency and Non -Emergency Applications Ratings Range Standby: kW kVA Prime: kW kVA 60 Hz 130-200 163-250 174-176 218-220 Generator Set Ratings Standard Features • Kohler Co. provides one -source responsibility for the generating system and accessories. • The generator set and its components are prototype -tested, factory -built, and production -tested. • The 60 Hz generator set offers a UL 2200 listing. • The generator set accepts rated load in one step. • The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. • A one-year limited warranty covers all generator set systems and components. Two- and five-year extended limited warranties are also available. • Alternator features: o The unique Fast -Response® II excitation system delivers excellent voltage response and short-circuit capability using a permanent magnet (PM) -excited alternator. o The brushless, rotating -field alternator has broadrange reconnectability. Alternator Voltage Ph 120/208 3 127/220 3 120/240 3 139/240 3 220/380 3 240/416 3 277/480 3 347/600 3 120/208 3 127/220 3 120/240 3 139/240 3 220/380 3 240/416 3 277/480 3 347/600 3 Hz 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Rich -Burn Natural Gas 130°C Rise 105°C Rise Standby Rating Prime Rating kW/kVA Amps kW/kVA Amps 200/250 694 174/218 604 200/250 656 175/219 574 200/250 601 174/218 523 200/250 601 176/220 529 200/250 380 174/218 330 200/250 347 174/218 302 200/250 301 176/220 265 200/250 241 176/220 212 200/250 200/250 200/250 200/250 200/250 200/250 200/250 200/250 694 656 601 601 380 347 301 241 176/220 176/220 176/220 175/219 176/220 176/220 175/219 175/219 611 577 529 526 334 305 263 210 Rich -Bum LP Gas (Vapor) 130°C Rise Standby Rating kW/kVA Amps 130/163 451 130/163 426 130/163 391 130/163 391 130/163 247 130/163 226 130/163 195 130/163 156 130/163 451 130/163 426 130/163 391 130/163 391 130/163 247 130/163 226 130/163 195 130/163 156 RATINGS: All three-phase units are rated at 0.8 power factor. Standby Ratings.: The standby rating is applicable to varying loads for the duration of a power outage. There Is no overload capability for this rating. Prune Rower Ratings: At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings am in accordance with ISo e52B.1 and ISO-304E-1. For linfted running time and continuous ratings, consult the factory. Obtain technical information bulletin (11B-101) for ratings guidelines, complete ratings definitions, and alte c ndtion dereles. The generator set manufacturer reserves the right to change the design or specifications whhout notice and without any obligation or lability whatsoever. For dual fuel engines, use the LP gas ratings for both the primary and secondary fuels. G4-1 BB (200REZXB) 1111 BT Alternator Specifications Specifications Alternator Manufacturer Type Exciter type Leads: quantity, type Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Voltage regulation, no-load to full -load One-step load acceptance Unbalanced load capability Peak motor starting kVA: 480 V 4UA10 480 V 4UA13 Engine Kohler 4-Pole, Rotating -Field Brushless, Permanent -Magnet 12, Reconnectable Solid State, Volts/Hz NEMA MG1 Class H 130°C, Standby 1, Sealed Flexible Disc Full Controller Dependent 100% of Rating 100% of Rated Standby Current (35% dip for voltages below) 790 (60Hz) 990 (60Hz) • NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. • Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. • Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. • Self -ventilated and dripproof construction. • Windings are vacuum -impregnated with epoxy varnish for dependability and long life. • Superior voltage waveform from a two-thirds pitch stator and skewed rotor. • Fast -Response® II brushless alternator with brushless exciter for excellent load response. Application Data Engine Electrical Engine Specifications Manufacturer Engine model Engine type Cylinder arrangement Displacement, L (cu. in.) Bore and stroke, mm (in.) Compression ratio Piston speed, m/min. (ft.lmin.) Main bearings: quantity, type Rated rpm Max. power at rated rpm, kWm (BHP) Cylinder head material Piston: type, material Crankshaft material Valve material Governor: type Frequency regulation, no-load to full -load Frequency regulation, steady state Frequency Air cleaner type, all models Exhaust Doosan D111TIC 11.1 L, 4-Cycle, Turbocharged, Aftercooled 6, Inline 11.05 (674) 123x 155 (4.84 x 6.10) 10.5:1 558 (1831) 7, Precision Half -Shell 1800 225 (302) Cast Iron Forged Steel Electronic Isochronous Fixed Dry Exhaust System Exhaust manifold type Exhaust flow at rated kW, kg/hr. (cfm) Exhaust temperature at rated kW, dry exhaust, °C (°F) Maximum allowable back pressure overall, kPa (in. Hg) Maximum allowable back pressure after catalyst, kPa (in. Hg) Engine exhaust outlet size, mm (in.) Wet 850 (1211) 600 (1112) 10.2 (3) 5.1 (1.5) Flanged Outlet at Catalyst, see ADV drawing Engine Electrical System Battery charging alternator: Ground (negative/positive) Negative Volts (DC) 24 Ampere rating 45 Starter motor rated voltage (DC) 24 Battery, recommended cold cranking amps (CCA): Qty., CCA rating each Two, 1000 Battery voltage (DC) 12 Fuel Fuel System - Rich Burn Fuel type Fuel supply line inlet Natural gas fuel supply pressure, kPa (in. H2O) LPG vapor withdrawal fuel supply pressure, kPa (in. H2O) Dual fuel engine, LPG vapor withdrawal fuel supply pressure, kPa (in. H2O) Natural Gas, LP Gas, or Dual Fuel 2.0 NPTF 1.74-2.74 (7.0-11.0) 1.24-2.74 (5.0-11.0) 1.24 (5.0) Fuel supply pressure, measured at the generator set fuel inlet downstream of any fuel system equipment accessories. Fuel Composition Limits * Nat. Gas LP Gas Methane, % by volume 90 min. Ethane, % by volume 4.0 max. — Propane, % by volume 1.0 max. 85 min. Propene, % by volume 0.1 max. 5.0 max. C4 and higher, % by volume 0.3 max. 2.5 max. Sulfur, ppm mass 25 max. Lower heating value, MJ/ms (Btu/ft ), min. 33.2 (890) 84.2 (2260) • Fuels with other compositions may be acceptable. If your fuel is outside the listed specifications, contact your local distributor for further analysis and advice. G4a88 (200REZXB) 1inef Application Data Lubrication Lubricating System Type Full Pressure Oil pan capacity, L (qt.) § 25 (26.4) Oil pan capacity with filter, L (qt.) § 27 (28.8) Oil filter quantity, type § 1, Cartridge Oil cooler Water -Cooled § Kohler recommends the use of Kohler Genuine oil and filters. Cooling Radiator System Ambient temperature, °C (° F) * Engine jacket water capacity, L (gal.) Radiator system capacity, including engine, L (gal.) Engine jacket water flow, Lpm (gpm) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) Heat rejected to air charge cooler at rated kW, dry exhaust, kW (Btu/min.) Water pump type Fan diameter, including blades, mm (in.) Fan, kWm (HP) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H2O) 50 (122) 21 (5.5) 116 (30.6) 284 (75) 142.3 (8100) 26.3 (1500) Centrifugal 965 (38) 13.4 (18) 0.125 (0.5) * Weather and sound enclosures with internal silencer reduce ambient temperature capability by 5°C (9°F). Operation Requirements Air Requirements Radiator -cooled cooling air, m3/min. (scam)'; Combustion air, kg/hr. (cfm) Heat rejected to ambient air: Engine, kW (Btu/min.) Alternator, kW (Btu/min.) t Air density = 1.20 kg/m3 (0.075 lbm/ft3) 510 (18000) 800 (390) 60.3 (3430) 16.0 (910) Fuel Consumption* Natural Gas, m3/hr. (cfh) at % load Standby Rating 100% 75% 50% 25% 59.9 (2115) 46.7 (1649) 32.8 (1158) 20.0 (706) Natural Gas, m3/hr. (cfh) at % load Prime Rating 100% 75% 50% 25% 53.6 (1893) 41.7 (1473) 29.7 (1049) 17.6 (622) LP Gas, m3/hr. (cfh) at % load Standby Rating 100% 75% 50% 25% Nominal fuel rating: 19.9 (703) 17.0 (600) 11.5 (406) 7.2 (254) Natural gas, 37 MJ/m3 (1000 Btu/ft.3) LP vapor, 93 MJ/m3 (2500 Btu/ft.3) LP vapor conversion factors: 8.58 ft.3 = 1 Ib. 0.535 m3 = 1 kg. 36,39 ft.3 = 1 gal. Controllers APM402 Controller Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. • Digital display and menu control provide easy local data access • Measurements are selectable in metric or English units 6 Remote communication thru a PC via network or serial configuration • Controller supports Modbuse protocol • integrated hybrid voltage regulator with t0.5% regulation • Built-in alternator thermal overload protection • NFPA 110 Level 1 capability Refer to G6-161 for additional controller features and accessories. 00 amer orin Decision -Maker 550 Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities. • Digital display and keypad provide easy local data access • Measurements are selectable in metric or English units • Remote communication thru a PC via network or modem configuration • Controller supports Modbuse protocol • Integrated voltage regulator with 10.25% regulation • Built-in alternator thermal overload protection • NFPA 110 Level 1 capability Refer to G6-46 for additional controller features and accessories. 0 pp. Decision -Maker 6000 Paralleling Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities for paralleling multiple generator sets. • Paralleling capability with first -on logic, synchronizer, kW and kVAR load sharing, and protective relays • Digital display and keypad provide easy local data access • Measurements are selectable in metric or English units • Remote communication thru a PC via network or modem configuration • Controller supports Modbuse protocol • Integrated voltage regulator with *0.25% regulation • Built-in alternator thermal overload protection • NFPA 110 Level 1 capability Refer to G6-107 for additional controller features and accessories. Modbjs+ Is a registered trademark of Schneider Electric. G4188 (200REZ)(5) 11 /18f KOHLERO KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Standard Features • Alternator Protection • Battery Rack and Cables • Closed Crankcase Ventilation (CCV) with Filters • Integral Vibration Isolation • Local Emergency Stop Switch • Low Coolant Level Shutdown • Oil Drain Extension • Operation and installation Literature • Three -Way Exhaust Catalyst Available Options Approvals and Listings ❑ CSA Certified ❑ IBC Seismic Certification ❑ UL 2200 Listing ❑ Hurricane Rated Enclosure Enclosed Unit ❑ Sound Enclosure with Internal Silencer (Aluminum) ❑ Sound Enclosure with Internal Silencer (Steel) ❑ Weather Enclosure with internal Silencer (Steel) Open Unit ❑ Exhaust Silencer, Critical (kit: PA-324470) ❑ Flexible Exhaust Connector, Stainless Steel Fuel System ❑ Dual Fuel, NG/LPG (Automatic Changeover) ❑ Flexible Fuel Lines (required when the generator set skid is spring mounted) ❑ Gas Filter ❑ Secondary Gas Solenoid Valve Controller ❑ Common Failure Relay ❑ Communications Products and PC Software ❑ Customer Connection (Decision -Maker® 550 controller only) ❑ Decision -Maker® Paralleling System (DPS) (Decision -Maker® 6000 controller only) ❑ Dry Contact Kit (isolated alarm) (Decision -Maker® 550 and 6000 controllers only) ❑ Two input/Five Output Module (APM402 controller only) ❑ Prime Power Switch (Decision -Maker® 550 and 6000 only) ❑ Remote Audiovisual Alarm Panel (Decision -Maker® 550 and 6000 controllers only) ❑ Remote Emergency Stop ❑ Remote Serial Annunciator Panel ❑ Run Relay ❑ Manual Speed Adjust (Decision -Maker® 550 and APM402 controllers only) Cooling System ❑ Block Heater, 2500 W, 90-120 V, 1 Ph ❑ Block Heater, 2500 W, 190-208 V, 1 Ph ❑ Block Heater, 2500 W, 210-240 V, 1 Ph ❑ Block Heater, 2500 W, 380-480 V, 1 Ph Required for ambient temperatures below 10°C (50°F) ❑ Radiator Duct Flange Electrical System ❑ Alternator Strip Heater ❑ Battery ❑ Battery Charger, Equalize/Float Type ❑ Battery Charger Temperature Compensation ❑ Battery Heater ❑ Line Circuit Breaker (NEMA1 enclosure) ❑ Line Circuit Breaker with Shunt Trip (NEMA1 enclosure) Miscellaneous ❑ Air Cleaner Restriction Indicator ❑ Certified Test Report ❑ Engine Fluids Added ❑ Rated Power Factor Testing ❑ Rodent Guards Literature ❑ General Maintenance ❑ NFPA 110 ❑ Overhaul ❑ Production Warranty ❑ 2-Year Basic Limited Warranty ❑ 2-Year Prime Limited Warranty ❑ 5-Year Basic Limited Warranty ❑ 5-Year Comprehensive Limited Warranty Other Options EI Dimensions and Weights Overall Size, L x W x H, max., mm (in.): Weight (radiator model), wet, max., kg (Ib.): T 3575 x 1350 x 1908 (140.7 x 53.1 x 75.1) 2722 (6000) L NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor for mare detailed iniormatlon. DISTRIBUTED BY: ® 2011, 2012, 2014, 2015, 2017, 2015 by Kohler Co. All rights reserved. G4-188 (200REZx8) 11 /t et