HomeMy WebLinkAboutSW3201002_100- 7 Eleven Long Ferry Road Construction Drawings 210118_20210119CLIENT M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-CS1.dwg, 1/15/2021 1:04:33 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-00552 Charlotte, NC 28277 CONTACT PROJECT DIRECTORY 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 CONSTRUCTION DRAWINGS PROJECT NUMBER: CPR-20000 DATE: SEPTEMBER 30, 2020 VICINITY MAP N.T.S. REVISIONS N0.DATE CONSTRUCTION DRAWINGS FOR: 7-ELEVEN - LONG FERRY ROAD 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 SALISBURY, NORTH CAROLINA PROJECT NUMBER: CPR-20000 C4 Store Holdings II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704. 414. 7472 JONATHAN WOODARD jwoodard@mcadamsco.com PHONE: 704. 527. 0800 x 320 FINAL DRAWING - RELEASED FOR CONSTRUCTION STORE NUMBER: 41905 GENERAL NOTES: 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.THERE MAY BE WETLANDS WITHIN THIS SITE. IT IS THE OWNER'S RESPONSIBILITY FOR WETLANDS JURISDICTION AND PERMIT DISTURBANCE PRIOR TO ANY GRADING ACTIVITY. SITE SHEET INDEX CS COVER SHEET C0.00 PROJECT NOTES C1.00 EXISTING CONDITIONS C1.01 DEMOLITION PLAN C2.00 SITE PLAN C3.00 GRADING & STORM DRAINAGE PLAN C4.00 UTILITY PLAN C4.01 OVERALL OFFSITE SEWER PLAN C5.00 PLAN AND PROFILE - SS O/F "100" STA. 0+00.00 THRU STA. 12+00 C5.01 PLAN AND PROFILE - SS O/F "100" STA. 12+00 THRU STA. 24+00 C5.02 PLAN AND PROFILE - SS O/F "100" STA. 24+00 THRU STA. 31+70.55 C5.03 PLAN AND PROFILE - LINE OF SIGHT DRIVEWAY 1 C5.04 PLAN AND PROFILE - LINE OF SIGHT DRIVEWAY 2 C5.05 PLAN AND PROFILE - LINE OF SIGHT DRIVEWAY 3 C6.00 EROSION & SEDIMENT CONTROL PLAN - STAGE I C6.01 EROSION & SEDIMENT CONTROL DETAILS C6.02 EROSION & SEDIMENT CONTROL DETAILS C7.00 LONG FERRY ROAD IMPROVEMENT PLAN C7.01 LONG FERRY ROAD PAVEMENT MARKING AND SIGNAGE LEGEND C7.02 LONG FERRY ROAD STATIONING PLAN C7.03 LONG FERRY ROAD EROSION CONTROL AND DEMOLITION PLAN C7.04 LONG FERRY ROAD GRADING PLAN C7.05 LONG FERRY ROAD TRAFFIC CONTROL PLAN C7.06 LONG FERRY ROAD TRUCK MOVEMENT PLAN C7.07 LONG FERRY ROAD CROSS SECTIONS STA. 0+00 THRU STA. 1+00 C7.08 LONG FERRY ROAD CROSS SECTIONS STA. 1+50 THRU STA. 2+50 C7.09 LONG FERRY ROAD CROSS SECTIONS STA. 3+00 THRU STA. 4+00 C7.10 LONG FERRY ROAD CROSS SECTIONS STA. 4+50 THRU STA. 5+50 C7.11 LONG FERRY ROAD CROSS SECTIONS STA. 6+00 THRU STA. 7+00 C7.12 LONG FERRY ROAD CROSS SECTIONS STA. 7+50 CS C8.00 SITE DETAILS C8.01 STORM DRAINAGE DETAILS C8.02 WATER & SANITARY SEWER DETAILS C8.03 ROADWAY IMPROVEMENT & PAVEMENT MARKING DETAILS C9.00 STORMWATER CONTROL MEASURE "A" PLAN VIEW C9.01 STORMWATER CONTROL MEASURE "A" DETAILS C9.02 STORMWATER CONTROL MEASURE "A" DETAILS C9.03 STORMWATER CONTROL MEASURE "A" DETAILS PROJECT CONTACT LIST DISCIPLINE COMPANY CONTACT CIVIL MCADAMS 704.527.0800 SURVEYOR SURVEY MATTERS 864.451.0176 ARCHITECTURAL BUF STUDIO 479.321.0478 STRUCTURAL MILLER ENGINEERING 503.246.1250 MEP BUF STUDIO 479.321.0478 FUEL CORE STATES GROUP 479.986.4400 REVISION: NOVEMBER 13, 2020 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 2 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ REVISION: JANUARY 6, 2021 DEMOLITION NOTES: 1.COORDINATE WITH DUKE ENERGY PRIOR TO ANY RELOCATION OR DEMOLITION OF THE EXISTING OVERHEAD POWER LINES. 2.THE CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES ON SITE PRIOR TO DEMOLITION. 3.THE CONTRACTOR SHALL PERFORM DEMOLITION ACTIVITIES AS NOTED AND SHOWN ON THESE PLANS AND AS DIRECTED BY THE OWNER. 4.IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ANY PERMITS AND PAY FEES REQUIRED FOR DEMOLITION AND HAUL-OFF FROM THE APPROPRIATE AUTHORITIES. THESE FEES ARE TO BE INCLUDED WITH THE BID. 5.THE CONTRACTOR SHALL PREPARE ALL DOCUMENTS AND ACQUIRE APPROPRIATE PERMITS AS REQUIRED PRIOR TO THE COMMENCEMENT OF DEMOLITION. 6.THE DEMOLITION PLAN IS INTENDED TO DEPICT GENERAL DEMOLITION AND UTILITY WORK. IT IS NOT INTENDED TO IDENTIFY EACH ELEMENT OF DEMOLITION OF RELOCATION. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND APPROPRIATE UTILITY COMPANY PRIOR TO WORK. 7.REMOVE AND DISPOSE OF ANY SIDEWALK, FENCES, STAIRS, WALLS, FOUNDATIONS, CONDUITS, LIGHT POLE BASES, DEBRIS AND RUBBISH REQUIRING REMOVAL FROM THE WORK AREA IN AN APPROVED LANDFILL. 8.CONTRACTOR SHALL COORDINATE WITH UTILITY DEPARTMENT IN THE REMOVAL/RELOCATION OF EXISTING POWER POLES AND OVERHEAD POWER LINES. 9.THE CONTRACTOR SHALL ARRANGE FOR RESETTING OF CURB BOXES, VALVE BOXES AND REMOVAL AND/OR RELOCATION OF OVERHEAD UTILITIES AND POLES WITH THE APPROPRIATE UTILITY COMPANY. 10.INSTALL ALL EROSION AND SEDIMENT CONTROL DEVICES AND TREE PROTECTION PRIOR TO BEGINNING DEMOLITION WORK. 11.THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITIES TO REMAIN IN PLACE. 12.THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO AVOID UNNECESSARY DAMAGE TO EXISTING ROAD SURFACE. 13.FINISH SURFACE TO BE REMOVED OR DEMOLISHED SHALL BE CUT ALONG LINES OF JOINTS WHICH WILL PERMIT A NEAT SURFACE WHEN RESTORED. 14.SAWCUT AT INTERFACE OF PAVEMENT OR CURB TO REMAIN. SAWCUT EXISTING PAVEMENT AT THE R/W. 15.ALL EXISTING ITEMS TO REMAIN WHICH ARE DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO ITS ORIGINAL CONDITION AT THE SOLE EXPENSE OF THE CONTRACTOR. 16.THE CONTRACTOR SHALL MAINTAIN ALL UTILITY SERVICES TO THE ADJOINING PROPERTIES DURING THE DEMOLITION PROCESS. 17.DO NOT INTERRUPT EXISTING UTILITIES SERVICING FACILITIES OCCUPIED AND USED BY THE OWNER OR OTHERS DURING OCCUPIED HOURS EXCEPT WHEN SUCH INTERRUPTIONS HAVE BEEN AUTHORIZED IN WRITING BY THE OWNER AND THE LOCAL MUNICIPALITIES. INTERRUPTIONS SHALL ONLY OCCUR AFTER ACCEPTABLE TEMPORARY SERVICE HAS BEEN PROVIDED. 18.SHOULD ANY UNCHARTED OR INCORRECTLY CHARTED EXISTING PIPING OR OTHER UTILITY BE UNCOVERED DURING EXCAVATION, CONSULT THE ENGINEER IMMEDIATELY FOR DIRECTIONS BEFORE PROCEEDING FURTHER WITH WORK IN THE IS AREA. 19.IN ACCORDANCE WITH 40 CFR, PART 61, SUBPART M, A THOROUGH INSPECTION SHALL BE CONDUCTED FOR ASBESTOS-CONTAINING MATERIALS, PRIOR TO CONDUCTING A RENOVATION OR DEMOLITION ACTIVITY OF AN EXISTING STRUCTURE. THE ASBESTOS INSPECTION MUST BE CONDUCTED BY A NORTH CAROLINA ACCREDITED ASBESTOS INSPECTOR. ALL REGULATED AND/OR FRIABLE ASBESTOS-CONTAINING MATERIALS IDENTIFIED DURING THE SURVEY, WHICH WILL BE DISTURBED, MUST BE PROPERLY REMOVED BY ACCREDITED INDIVIDUALS BEFORE BEGINNING THE RENOVATION OR DEMOLITION ACTIVITY. IF REGULATED AND/OR FRIABLE ASBESTOS CONTAINING MATERIALS TO BE REMOVED EXCEED 160 SQUARE FEET, 260 LINEAR FEET OR 35 CUBIC FEET, A PERMIT SHALL BE APPLIED FOR THROUGH THE NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES. 20.UTILITY APPURTENANCES TO BE REMOVED INCLUDE BUT AREN'T LIMITED TO HYDRANTS, FIRE DEPARTMENT CONNECTIONS, VALVES/VALVE BOXES, STORM DRAIN AND/OR SANITARY SEWER CLEANOUTS, STORM DRAIN INLETS. EROSION CONTROL NOTES: 1.ALL "STD." NUMBERS REFER TO THE NORTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL (NCDHEC) STANDARDS MANUAL. 2.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROM THE ZONING ADMINISTRATOR. 3.ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. 4.GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO FINE. 5.ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1) SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 DAYS CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 14 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY. 6.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF THE NCDEQ ENGINEERING DEPARTMENT. 7.A GRADING PLAN MUST BE SUBMITTED FOR ANY LOT GRADING EXCEEDING ONE ACRE THAT WAS NOT PREVIOUSLY APPROVED. 8.DRIVEWAY PERMITS FOR CONSTRUCTION ENTRANCES IN NCDOT RIGHT OF WAY MUST BE PRESENTED AT PRE CONSTRUCTION MEETING. 9.THIS SITE IS TO BE INSPECTED AND DOCUMENTED IN ACCORDANCE WITH THE NC GENERAL CONSTRUCTION PERMIT. 10.AREA UNDER EMBANKMENT SHALL BE CLEARED, GRUBBED, AND STRIPPED OF ANY VEGETATION AND ROOT MATERIAL. THE BASIN AREA SHALL BE CLEARED. 11.THE FILL MATERIAL FOR THE EMBANKMENT SHALL BE FREE OF ROOTS OR OTHER WOODY VEGETATION AS WELL AS OVERSIZED STONES, ROCKS, ORGANIC MATERIAL OR OTHER OBJECTIONABLE MATERIAL. THE EMBANKMENT SHALL BE COMPACTED BY TRAVERSING WITH EQUIPMENT WHILE BEING CONSTRUCTED. SPILLWAYS SHOULD NOT BE CONSTRUCTED THROUGH FILL SECTIONS. ALL SPILLWAYS SHOULD BE LINED AND/OR RIP-RAPPED. 12.SEDIMENT SHALL BE REMOVED AND TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO DEPTH SHOWN ON STANDARD. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA IN SUCH A MANNER THAT IT WILL NOT ERODE. 13.THE TRAP SHALL BE INSPECTED AFTER EACH MEASURABLE RAIN AND REPAIRS MADE AS NECESSARY. 14.CONSTRUCTION OPERATION SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND WATER POLLUTION IS MINIMIZED. 15.ALL CUT AND FILL SLOPES SHALL BE 2:1 OR FLATTER, UNLESS CERTIFIED BY REGISTERED GEOTECHNICAL ENGINEER. 16.SEDIMENT BASIN EMBANKMENTS SHOULD BE PROVIDED WITH EROSION CONTROL AND STABILIZATION. 17.THE BASIN SHOULD ALSO BE ORIENTED SUCH THAT THE FILTER AND THE MAIN FLOW OF WATER AND SEDIMENT ARE ON OPPOSITE ENDS ON THE LONGER BASIN DIMENSIONS. 18.WHENEVER TOPOGRAPHY ALLOWS, THE BASIN LENGTH SHOULD BE TWICE (2X) THE BASIN WIDTH, TO ALLOW FOR SETTLING. BAFFLES SHALL BE INSTALLED IN ALL BASINS. 19.CLEANOUT STAKES SHALL BE PLACED IN ALL SEDIMENT BASINS AT THE LOW POINT IN THE BASIN. THE STAKES SHALL BE MARKED SHOWING THE HALF FULL, CLEANOUT POINT, OF THE BASIN. 20.SAFETY FENCING 3' HIGH SHOULD BE PLACED AROUND ALL SEDIMENT BASINS. 21.FOR DESIGN OF SEDIMENT BASINS, REFER TO THE NORTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL STANDARDS MANUAL. 22.FOR SLOPES GREATER THAN 10' IN LENGTH AND PROTECTED BY SILT FENCE AT THE TOE OF THE SLOPE, SLOPE TERRACING WILL BE REQUIRED. 23.THE BERM ON SEDIMENT BASINS SHALL BE SEEDED ONCE FINAL GRADE HAS BEEN REACHED. THE SILT FENCE MAY BE REMOVED IF PERMISSION HAS BEEN GRANTED BY THE CITY LAND DEVELOPMENT INSPECTOR AFTER THE GRASS HAS GERMINATED AND STABLE GROUND HAS BEEN ESTABLISHED. 24.WASHED STONE AND WIRE BACKING SHALL BE USED WITH SILT FENCE WHENEVER SILT FENCE IS PLACED AT THE TOE OF A SLOPE >10' VERTICAL OR ALONG ANY CHANNEL OR WATER COURSE WHERE 50' OF BUFFER IS NOT PROVIDED. 25.ALL TREES & BRUSH REMOVED DURING CLEARING & GRUBBING OF SITE SHALL BE CHIPPED ON SITE AND HAULED OFF SITE FOR DISPOSAL. 26.ALL DISTURBED AREAS TO BE SEEDED. 27.NO DEMOLITION TO OCCUR PRIOR TO PRE-CONSTRUCTION MEETING. NCDEQ STANDARD NOTES: 1.IF NECESSARY, SLOPES, WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BE STABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING. IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHT TO GRADE. 2.STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORD HAS CEASED, EXCEPT AS STATED BELOW. ·WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND CONDITIONS STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICABLE. ·WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED AND EARTH-DISTURBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. 3.ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED ONCE EVERY CALENDAR WEEK. IF PERIODIC INSPECTION OR OTHER INFORMATION INDICATES THAT A BMP HAS BEEN INAPPROPRIATELY, OR INCORRECTLY, THE PERMITTEE MUST ADDRESS THE NECESSARY REPLACEMENT OR MODIFICATION REQUIRED TO CORRECT THE BMP WITHIN 48 HOURS OF IDENTIFICATION. 4.PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE SEDIMENT BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE. 5.ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRICTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED. 6.THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAY BE REQUIRED. 7.TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR TO DIVERT SEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. 8.ALL WATERS OF THE STATE (WOS) , INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50- FOOT BUFFER CANT BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL WOS. A 10- FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS. 9.LITTER, CONSTRUCTION DEBRIS, OIL, FUELS, AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORM WATER DISCHARGES. 10.A COPY OF THE SWPPP, INSPECTIONS RECORDS, AND RAINFALL DATA MUST BE RETAINED AT THE CONSTRUCTION SITE OR A NEARBY LOCATION EASILY ACCESSIBLE DURING NORMAL BUSINESS HOURS, FROM THE DATE OF COMMENCEMENT OF CONSTRICTION ACTIVITIES TO THE DATE THAT FINAL STABILIZATION IS REACHED. 11.INITIATE STABILIZATION MEASURES ON ANY EXPOSED STEEP SLOPE (3H:1V OR GREATER) WHERE LAND-DISTURBING ACTIVITIES HAVE PERMANENTLY OR TEMPORARILY CEASED, AND WILL NOT RESUME FOR A PERIOD OF 7 CALENDAR DAYS. 12.MINIMIZE SOIL COMPACTION AND, UNLESS INFEASIBLE, PRESERVE TOPSOIL. 13.MINIMIZE THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER, AND OTHER WASH WATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE CONTROL THAT PROVIDES EQUIVALENT OR BETTER TREATMENT PRIOR TO DISCHARGE. 14.MINIMIZE THE DISCHARGE OF POLLUTANTS FROM DEWATERING OF TRENCHES AND EXCAVATED AREAS. THESE DISCHARGES ARE TO BE ROUTED THROUGH APPROPRIATE BMPS (SEDIMENT BASIN, FILTER BAD, ETC.). 15.THE FOLLOWING DISCHARGES FROM SITES ARE PROHIBITED: ·WASTEWATER FROM WASHOUT OF CONCRETE, UNLESS MANAGED BY AN APPROPRIATE CONTROL; ·WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OILS, CURING COMPOUNDS AND OTHER CONSTRUCTION MATERIALS; ·FUELS, OILS, OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE; AND ·SOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING. 16.AFTER CONSTRUCTION ACTIVITIES BEGIN, INSPECTIONS MUST BE CONDUCTED AT A MINIMUM OF AT LEAST ONCE EVERY CALENDAR WEEK AND MUST BE CONDUCTED UNTIL FINAL STABILIZATION IS REACHED ON ALL AREAS OF THE CONSTRUCTION SITE. 17.IF EXISTING BMPS NEED TO BE MODIFIED OR IF ADDITIONAL BMOS ARE NECESSARY TO COMPLY WITH THE REQUIREMENTS OF THIS PERMIT AND/OR NC'S WATER QUALITY STANDARDS, IMPLEMENTATION MUST BE COMPLETED BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. IF IMPLEMENTATION BEFORE THE NEXT STORM EVENT IS IMPRACTICABLE, THE SITUATION MUST BE DOCUMENTED IN THE SWPPP AND ALTERNATIVE BMPS MUST BE IMPLEMENTED AS SOON AS REASONABLY POSSIBLE. 18.A PRE-CONSTRUCTION CONFERENCE MUST BE HELD FOR EACH CONSTRUCTION SITE WITH AN APPROVED ON-SITE SWPPP PRIOR TO THE IMPLEMENTATION OF CONSTRUCTION ACTIVITIES. FOR NON-LINEAR PROJECTS THAT DISTURB 10 ACRES OR MORE THIS CONFERENCE MUST BE HELD ON-SITE UNLESS THE DEPARTMENT HAS APPROVED OTHERWISE. GENERAL STORM DRAINAGE NOTES: 1.ALL WORK AND MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE NCDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE SPECIFIED IN THIS MANUAL. ALL CONCRETE USED FOR DRAINAGE STRUCTURES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3600 PSI AT 28 DAYS. THIS REQUIREMENT SHALL BE PROVIDED REGARDLESS OF ANY LESSER COMPRESSIVE STRENGTH SPECIFIED IN THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES. 2.REINFORCED CONCRETE PIPE MAY BE USED IN ALL STORM DRAIN APPLICATIONS. HIGH DENSITY POLYETHYLENE PIPE (HDPE) MAY BE SUBSTITUTED FOR PIPE DIAMETERS OF 48 INCHES OR LESS. CULVERTS 60 INCHES IN DIAMETER OR GREATER MAY BE CORRUGATED ALUMINIZED METAL PIPE (CAMP) OR ALUMINUM WITH A MINIMUM 14 GAUGE METAL. 3.ALL PIPE SHALL BE LAID WITH THE BELL OR GROOVE UPGRADE AND THE JOINT ENTIRELY INTERLOCKING. 4.THE MINIMUM COVER FOR ALL PIPES IS TWO (2) FEET MEASURED FROM THE FINAL SURFACE. SPECIAL APPLICATIONS FOR LESS THAN TWO (2) FEET OF COVER WILL BE REVIEWED AND APPROVED BY THE CITY ENGINEER INDIVIDUALLY. THE MAXIMUM COVER FOR STORM DRAINAGE PIPES SHALL AT A MINIMUM COMPLY WITH THE REQUIREMENTS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION HIGHWAY DESIGN BRANCH ROADWAY DESIGN MANUAL, PART I, SECTION 5, AND "DRAINAGE DESIGN". STORM PIPE DESIGN THAT EXCEEDS THESE CRITERIA MAY BE APPROVED AT THE DISCRETION OF THE CITY ENGINEER. 5.ALL PIPES IN STORM DRAIN STRUCTURES SHALL BE FLUSH WITH THE INSIDE WALL. 6.ALL STORM DRAIN STRUCTURES OVER THREE (3) FEET AND SIX (6) INCHES IN HEIGHT MUST HAVE STEPS IN ACCORDANCE WITH STANDARD DETAILS SET FORTH IN THIS MANUAL. 7.THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 8.STORM DRAINAGE PIPING SHALL BE PLACED IN A STRAIGHT ALIGNMENT AT UNIFORM GRADE. NO CHANGES IN ALIGNMENT SHALL BE ALLOWED EXCEPT AT CATCH BASINS, MANHOLES, OR OTHER JUNCTIONS THAT PROVIDE APPROPRIATE CLEAN OUT ACCESS. THE MAXIMUM LENGTH BETWEEN ACCESS POINTS IS 300 LINEAR FEET. 9.ALL FRAMES, GRATES, RINGS, COVERS, ETC., MUST CONFORM TO THE STANDARDS SET FORTH IN THIS MANUAL. 10.ALL GRADED CREEK BANKS AND SLOPES SHALL BE AT A MAXIMUM OF TWO (2) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL (2:1) AND NOT TO EXCEED 10' WITHOUT TERRACING OR THE SLOPES SHALL BE DESIGNED BY A PROFESSIONAL GEOTECHNICAL ENGINEER AND APPROVED BY THE CITY ENGINEER ON A CASE BY CASE BASIS. 11.ALL CONCRETE SHALL BE AT LEAST 3600 PSI. PRIOR APPROVAL SHALL BE OBTAINED IN ORDER TO USE PRE-CAST STORM DRAINAGE STRUCTURES IN ANY STREET RIGHT-OF-WAY BY CITY ENGINEER. 12.CONCRETE PIPE USED WITHIN THE STREET RIGHT-OF-WAY SHALL BE A MINIMUM OF CLASS III REINFORCED CONCRETE PIPE, WITH AMINIMUM DIAMETER OF FIFTEEN (15) INCHES (EIGHTEEN (18) INCHES MINIMUM ON CROSS DRAIN CULVERTS WITHIN THE ETJ). INSTALLATION OF CLASS IV OR HIGHER CONCRETE PIPE SHALL BE IDENTIFIED ON THE AS-BUILT PLAN AND THE CITY INSPECTOR SHALL BE GIVEN DOCUMENTATION AND NOTIFICATION OF THIS INFORMATION PRIOR TO CONSTRUCTION. 13.CONCRETE MORTAR JOINTS SHALL BE USED FOR JOINING ALL CONCRETE PIPES. THE PIPE SHALL BE CLEAN AND MOIST WHEN MORTAR IS APPLIED. THE LOWER PORTIONS OF THE BELL OR GROOVE SHALL BE FILLED WITH MORTAR SUFFICIENT TO BRING THE INNER SURFACE FLUSH AND EVEN WHEN THE NEXT JOINT IS FITTED INTO PLACE. THE REMAINDER OF THE JOINT SHALL THEN BE FILLED WITH MORTAR AND A BEAD OR RING OF MORTAR FORMED AROUND THE OUTSIDE OF THE JOINT. THE APPLICATION OF MORTAR MAY BE DELAYED UNTIL FILL IS COMPLETED WHEN THE PIPE IS LARGER THAN THIRTY (30) INCHES. 14.PERFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS, MAY BE USED IN LIEU OF THE MORTAR JOINING METHOD. 15.THE PRODUCT USED SHALL BE CORRUGATED EXTERIOR/SMOOTH INTERIOR PIPE (TYPE S), CONFORMING TO THE REQUIREMENTS OF AASHTO SPECIFICATION M294 (LATEST EDITION) FOR CORRUGATED POLYETHYLENE PIPE. 16.BELL AND SPIGOT JOINTS SHALL BE REQUIRED ON ALL PIPES INSIDE THE RIGHT-OF-WAY. BELLS SHALL COVER AT LEAST TWO FULL CORRUGATIONS ON EACH SECTION OF PIPE. THE BELL AND SPIGOT JOINT SHALL HAVE AN "O" RING RUBBER GASKET MEETING ASTM F477 WITH THE GASKET FACTORY INSTALLED, PLACED ON THE SPIGOT END OF THE PIPE. PIPE JOINTS SHALL MEET ALL REQUIREMENTS OF AASHTO M294. 17.ALL HDPE PIPE INSTALLED MUST BE INSPECTED AND APPROVED BY THE CITY'S INSPECTOR PRIOR TO ANY BACKFILL BEING PLACED. THE CITY INSPECTOR MUST BE PRESENT DURING THE BACKFILLING OPERATION AS WELL. 18.BACKFILL MATERIAL USED TO INSTALL HDPE PIPE WITHIN THE STREET RIGHT-OF-WAY SHALL BE SELECT MATERIAL, CLASS II-IV, AS DEFINED BY SECTION 1016-3 OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES. UPON SUBMITTAL OF WRITTEN CERTIFICATION OF MATERIAL SUITABILITY BY A LICENSED GEOTECHNICAL ENGINEER, NCDOT CLASS I SELECT MATERIAL MAY BE USED. ALL BACKFILL MATERIAL SHALL BE APPROVED BY THE CITY INSPECTOR PRIOR TO PLACEMENT OF THE MATERIAL WITHIN THE STREET RIGHT-OF-WAY. 19.THE MINIMUM LENGTH OF HDPE PIPE PERMITTED FOR USE SHALL BE FOUR (4) FEET. HDPE FLARED END SECTIONS ARE NOT ALLOWED. 20.ALL HDPE PIPE INSTALLED SHALL BE THIRD PARTY CERTIFIED AND SHALL BEAR THE PLASTIC PIPE INSTITUTE'S (PPI) CERTIFICATE STICKER. 21.ALL BACKFILL SHALL BE NON-PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATIVE MATTER, WASTE, CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 22.MATERIALS DEEMED BY THE ENGINEER AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SELECT BACKFILL MATERIAL. 23.BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER THE PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE PLACED IN LAYERS NOT TO EXCEED EIGHT (8) INCHES, EACH LAYER SHALL BE THOROUGHLY COMPACTED TO 95% OF THE MAXIMUM DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST (A DENSITY OF 100% STANDARD PROCTOR IS REQUIRED FOR THE TOP EIGHT (8) INCHES). 24.COMPACTION REQUIREMENTS SHALL BE ATTAINED BY THE USE OF MECHANICAL COMPACTION METHODS. EACH LAYER OF BACKFILL SHALL BE PLACED LOOSE AND THOROUGHLY COMPACTED IN PLACE. 25.UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED TO RISE IN UN-BACKFILLED TRENCHES AFTER THE PIPE HAS BEEN PLACED. GROUND STABILIZATION SITE AREA DESCRIPTION STABILIZATION TIME FRAME STABILIZATION TIME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES AND SLOPES 7 DAYS NONE HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7-DAYS FOR SLOPES GREATER THAN 50 FEET IN LENGTH ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 14 DAYS NONE (EXCEPT FOR PERIMETERS AND HQW ZONES) C0.00 NTS PROJECT NOTES CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-N1.dwg, 1/5/2021 12:03:28 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-N1 FINAL DRAWING - RELEASED FOR CONSTRUCTION CONSTRUCTION SEQUENCE - STAGE I ENFORCEMENT NOTE 1: FAILURE TO FOLLOW THIS CONSTRUCTION SEQUENCE MAY RESULT IN ENFORCEMENT ACTIONS, INCLUDING BUT NOT LIMITED TO CIVIL PENALTIES, INJUNCTIVE RELIEF, CRIMINAL PENALTIES, AND PERMIT REVOCATION. ADDITIONALLY, OFF-SITE SEDIMENTATION DISCHARGE MAY RESULT IN RESTORATION REQUIREMENTS. ENFORCEMENT NOTE 2: IF EXCESSIVE SEDIMENT IS LEAVING THE SITE, A REVISED SEDIMENT AND EROSION CONTROL PLAN MAY BE REQUIRED, WITH ASSOCIATED REQUIREMENTS FOR ADDITIONAL S&E MEASURES. 1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM ROWAN COUNTY, DRIVEWAY PERMIT FROM NCDOT, AND OTHER APPLICABLE PERMITS AND KEEP HARD-COPIES POSTED ON-SITE. 2.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH THE EROSION CONTROL INSPECTOR OTO DISCUSS EROSION CONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIOR TO ANY LAND DISTURBING ACTIVITY IS A VIOLATION AND SUBJECT TO A FINE. 3.UPON APPROVAL FROM NCDOT INSTALL THE TEMPORARY CONSTRUCTION ENTRANCE AND ASSOCIATED MEASURES PER CONSTRUCTION DRAWINGS AND NCDOT STANDARDS. 4.INSTALL PERIMETER MEASURES INCLUDING, BUT NOT LIMITED TO, SILT FENCE (STANDARD AND HIGH HAZARD) AND SILT FENCE OUTLETS CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. CONTRACTOR TO INSTALL ADDITIONAL STONE SILT FENCE OUTLETS AS REQUIRED AROUND THE SITE PERIMETER TO RELIEVE PRESSURE FROM THE SILT FENCE AS DIRECTED BY THE INSPECTOR OR AS A RESULT OF CONSTRUCTION CONDITIONS. 5.CLEAR AREA REQUIRED TO INSTALL SKIMMER SEDIMENT BASIN A. 6.INSTALL THE PROPOSED SKIMMER SEDIMENT BASIN AND ITS RESPECTIVE FEATURES INCLUDING SKIMMER, POROUS BAFFLES, SLOPE MATTING, PERMANENT RISER AND RESPECTIVE DISCHARGE PIPE. STOCKPILE EXCESS MATERIAL AT AN INSPECTOR APPROVED LOCATION IF NECESSARY. PROVIDE THE NECESSARY EROSION CONTROL MEASURES AT EACH STOCKPILE LOCATION. 7.INSTALL THE TEMPORARY PIPE SLOPE DRAINS AND THEIR ASSOCIATED RIP-RAP APRONS AS SHOWN. 8.INSTALL THE TEMPORARY DIVERSIONS SHOWN ON THESE PLANS AND PROVIDE THE NECESSARY CHECK DAMS AS SHOWN. 9.THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 10.ALL AREAS THAT WILL GO UNWORKED FOR 14 DAYS OR MORE MUST BE STABILIZED IMMEDIATELY. STABILIZATION STANDARDS SHOULD BE MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. 11.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, THE U.S. DEPT. OF AGRICULTURE, AND ROWAN COUNTY STANDARDS. 12.CALL FOR ON-SITE INSPECTION BY INSPECTOR. WHEN APPROVED, INSPECTOR ISSUES THE GRADING PERMIT AND CLEARING AND GRUBBING MAY BEGIN. LIMIT CLEARING AND GRUBBING OF SITE TO AREAS THAT WILL BE MASS GRADED. WHENEVER POSSIBLE, EXISTING VEGETATION SHALL REMAIN IN-PLACE TO PREVENT EROSION OF SITE. 13.BEGIN MASS GRADING ACTIVITIES. 14.AS SITE IS BROUGHT TO GRADE, BUILDING CONSTRUCTION SHALL COMMENCE. CONTRACTOR TO INSTALL ANY ADDITIONAL EROSION CONTROL MEASURES. BUILDINGS 3 AND 4 CANNOT BE BUILT UNTIL THE SEDIMENT BASIN IS REMOVED FROM THE RESPECTIVE BUILDING FOOTPRINT UPON DIRECTION FROM SITE INSPECTOR. 15.BEGIN INSTALL OF PROPOSED UTILITIES. 16.RUNOFF FROM THE PROPOSED BUILDING PAD AREAS, AND OTHER RELATIVELY LEVEL AREAS SHOULD NOT BE ALLOWED TO SHEET FLOW OVER FILL SLOPES. DURING THE FILL PLACEMENT PROCESS THE CONTRACTOR SHOULD MAINTAIN DIVERSIONS ALONG THE TOP OF FILL SLOPES WHICH SHOULD DRAIN TO SLOPE DRAINS. THESE MEASURES SHOULD REMAIN IN PLACE UNTIL THE FILL SLOPES HAVE BEEN ADEQUATELY STABILIZED WITH ESTABLISHED VEGETATION. 17.INSTALL INLET PROTECTION, AND OTHER MEASURES, AS SHOWN AS THE PROPOSED STORM SEWER SYSTEM IS INSTALLED. WHEN APPLICABLE THE CONTRACTOR SHOULD MINIMIZE THE DISTURBANCE ALLOWED AT ONE TIME TO THE GREATEST EXTENT PRACTICAL. 18.STABILIZE SITE AS AREAS ARE BROUGHT TO FINAL GRADE. 19.ALL AREAS THAT WILL GO UNWORKED FOR 14 DAYS OR MORE MUST BE STABILIZED IMMEDIATELY. STABILIZATION STANDARDS SHOULD BE MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. 20.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N. C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U. S. DEPT. OF AGRICULTURE, AND ROWAN COUNTY STANDARDS. 21.THE LAND DEVELOPMENT INSPECTOR SHOULD BE CALLED TO CONDUCT INSPECTIONS ON STORM DRAINAGE, SIDEWALKS, DRIVEWAY IMPROVEMENTS, AND ALL ASPECTS OF ROAD CONSTRUCTION. 22.WHEN VEGETATION IS ESTABLISHED, CALL FOR SITE INSPECTION, IF THE SITE IS APPROVED THE CONTRACTOR MAY REMOVE THE IN-PLACE E&SC MEASURES AND CONVERT SEDIMENT BASIN A TO A PERMANENT SAND FILTER. C1.00 EXISTING CONDITIONS GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) 1"=30' EXISTING CONDITIONS LEGEND CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XC1.dwg, 10/20/2020 11:26:17 AM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-XC1 FINAL DRAWING - RELEASED FOR CONSTRUCTION N/F LARRY R. BARNETTE PID: 052 095 DB. 1295, PG. 611 ZONING: IB JAMES EDWARD EPTING HIERS PID: 052 213 DB. 1280, PG. 358 ZONING: CBI 176,466 S.F.= 4.051 AC VICINITY MAP N.T.S. SITE FOR REFERENCE ONLYFOR R E F E R E N C E O NL Y C1.01 DEMOLITION PLAN GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) 1"=30' EXISTING CONDITIONS LEGEND CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-DM1.dwg, 1/5/2021 12:07:28 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-DM1 FINAL DRAWING - RELEASED FOR CONSTRUCTION N/F LARRY R. BARNETTE PID: 052 095 DB. 1295, PG. 611 ZONING: IB (VACANT) JAMES EDWARD EPTING HIERS PID: 052 213 DB. 1280, PG. 358 ZONING: CBI 176,466 S.F.= 4.051 AC VICINITY MAP N.T.S. SITE DEMOLITION LEGEND CAT SCALEGRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) 1"=30' VICINITY MAP N.T.S. CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-S1.dwg, 1/15/2021 1:04:56 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-S1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C2.00 SITE PLAN ZONING: CURRENT USE: PROPOSED USE: BUILDING GROSS FLOOR AREA: FRONT SETBACK: LONG FERRY RD FRONT CREEK RD SIDE YARD: REAR YARD: PROPOSED PARKING SPACES: PROPOSED HC SPACES: OPERATION HOURS ESTIMATED # OF EMPLOYEES AT LARGEST SHIFT FEMA FLOOD PANELS CBI VACANT COMMERCIAL & RESIDENTIAL GAS STATION/CONVENIENCE 4,743 SF 50' FROM R/W 50' FROM R/W 10'/30' STREET 10' 72 SPACES (14 TRUCK) 2 SPACES (1 VAN) 24 HOURS 7 DAYS A WEEK 4 5780 & 5781K 4.10052 213 ACREAGE: SITE DATA PID: JAMES EDWARD EPTING HEIRSCURRENT OWNER: 1280 DB: 358PG: SITE LEGEND STORMWATER CONTROL MEASURE 4,743 SF 7-ELEVEN STORE CONTRACTOR SHALL NOTIFY "SC811" (811) OR (1-800-721-7877) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "SC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R N/F LARRY R. BARNETTE PID: 052 095 DB. 1295, PG. 611 ZONING: IB (VACANT) EXISTING CONDITIONS LEGEND 57 SPACES 14 TRUCK SPACES 4.10 AC 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 2 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ CAT SCALEGRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) 1"=30' VICINITY MAP N.T.S. CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-G1.dwg, 1/15/2021 1:05:23 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-G1 FINAL DRAWING - RELEASED FOR CONSTRUCTION STORMWATER CONTROL MEASURE 4,379 SF 7-ELEVEN STORE CONTRACTOR SHALL NOTIFY "SC811" (811) OR (1-800-721-7877) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "SC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING CONDITIONS LEGEND C3.00 GRADING & STORM DRAINAGE PLAN GRADING LEGEND L= 46.751, R=33 6 . 4 8 0 L= 285.686, R=190.000FFE=714.40 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ 2 01.15.2021 REVS PER NCDEQ SCM CAT SCALEGRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R 1"=30' VICINITY MAP N.T.S. CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-U1.dwg, 1/15/2021 1:06:17 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-U1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C4.00 UTILITY PLANCONTRACTOR SHALL NOTIFY "SC811" (811) OR (1-800-721-7877) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "SC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING CONDITIONS LEGEND UTILITY LEGEND EXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) N/F LARRY R. BARNETTE PID: 052 095 DB. 1295, PG. 611 ZONING: IB (VACANT) JAMES EDWARD EPTING HIERS PID: 052 213 DB. 1280, PG. 358 ZONING: CBI 176,466 S.F.= 4.051 AC STORMWATER CONTROL MEASURE 4,650 SF 7-ELEVEN STORE 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ 1"=100' GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. C5.00 C5.01 C5.02 CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-OAU1.dwg, 1/15/2021 1:05:55 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-OAU1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C4.01 OVERALL OFFSITE SEWER PLAN N/F LARRY R. BARNETTE PID: 052 095 DB. 1295, PG. 611 ZONING: IB (VACANT) JAMES EDWARD EPTING HIERS PID: 052 213 DB. 1280, PG. 358 ZONING: CBI 176,466 S.F.= 4.051 AC EXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EX. SSMH-100 - SSMH-116 C5.00 SS O/F "100", STA. 0+00 THRU STA. 12+00CPR-20000 JBW LSE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-P1-SS M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-P1-SS.dwg, 1/5/2021 1:29:59 PM, Woodard, JonathanPLAN AND PROFILECLIENTREVISIONS N0.DATE PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 1"=40'/1"=4' SS-100 EROSION CONTROL LEGEND GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 2 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ EX. SSMH-100 - SSMH-116 C5.01 SS O/F "100", STA. 12+00 THRU STA. 24+00CPR-20000 JBW LSE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-P1-SS M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-P1-SS.dwg, 1/5/2021 1:30:30 PM, Woodard, JonathanPLAN AND PROFILECLIENTREVISIONS N0.DATE PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 1"=40'/1"=4' SS-100EROSION CONTROL LEGEND GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. REVS PER CITY/COUNTY/NCDOT COMMENTS11.13.20201 CAT SCALEEX. SSMH-100 - SSMH-116 C5.02 SS O/F "100", STA. 24+00 THRU STA. 31+70.55CPR-20000 JBW LSE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-P1-SS M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-P1-SS.dwg, 1/15/2021 1:06:50 PM, Doan, DianaPLAN AND PROFILECLIENTREVISIONS N0.DATE PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 1"=40'/1"=4' SS-100 EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EROSION CONTROL LEGEND GRAPHIC SCALE 0 20 40 80 1 inch = 40 ft. JAMES EDWARD EPTING HIERS PID: 052 213 DB. 1280, PG. 358 ZONING: CBI 176,466 S.F.= 4.051 AC REVS PER CITY/COUNTY/NCDOT COMMENTS11.13.20201 LINE OF SIGHT - DRIVEWAY 1 CPR-20000 JBW LSE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-P2-LOS M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-P2-LOS.dwg, 1/5/2021 1:33:05 PM, Woodard, JonathanPLAN AND PROFILECLIENTREVISIONS N0.DATE PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C5.03 LINE OF SIGHT - DRIVEWAY 1 1"=40'/1"=4' LONG FERRY ROAD LONG FERRY ROAD POSTED SPEED LIMIT 45 MPH EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) LINE OF SIGHT - DRIVEWAY 2 CPR-20000 JBW LSE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-P2-LOS M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-P2-LOS.dwg, 1/15/2021 1:07:11 PM, Doan, DianaPLAN AND PROFILECLIENTREVISIONS N0.DATE PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C5.04 LINE OF SIGHT - DRIVEWAY 2 1"=40'/1"=4' FRONT CREEK ROAD FRONT CREEK ROAD SPEED LIMIT 35 MPHEXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) LINE OF SIGHT - DRIVEWAY 3 CPR-20000 JBW LSE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-P2-LOS M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-P2-LOS.dwg, 1/15/2021 1:07:19 PM, Doan, DianaPLAN AND PROFILECLIENTREVISIONS N0.DATE PROJECT NO. FILENAME CHECKED BY DRAWN BY SCALE DATE The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C5.05 LINE OF SIGHT - DRIVEWAY 3 1"=40'/1"=4' FRONT CREEK ROAD FRONT CREEK ROAD SPEED LIMIT 35 MPHEXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) C6.00 EROSION & SEDIMENT GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R EXISTING FRONT CREEK ROAD (SR 2182) (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) 1"=30' EXISTING CONDITIONS LEGEND CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-EC1.dwg, 1/15/2021 1:07:40 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-EC1 FINAL DRAWING - RELEASED FOR CONSTRUCTION N/F LARRY R. BARNETTE PID: 052 095 DB. 1295, PG. 611 ZONING: IB (VACANT) JAMES EDWARD EPTING HIERS PID: 052 213 DB. 1280, PG. 358 ZONING: CBI 176,466 S.F.= 4.051 AC VICINITY MAP N.T.S. SITE CONTROL PLAN - STAGE I EROSION CONTROL LEGEND TOTAL DISTURBED AREA = 7.00 AC. REFER TO SHEET C0.00 FOR THE DETAILED CONSTRUCTION SEQUENCING L= 46.751, R=3 3 6 . 4 8 0 L= 285.686, R=190.000 C6.01 CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-EC2.dwg, 1/15/2021 1:08:09 PM, Doan, DianaThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-EC2 FINAL DRAWING - RELEASED FOR CONSTRUCTION EROSION & SEDIMENT CONTROL DETAILS N/A A 4.03 3.65 17.20 6984 9897 5590 5978 1 2 3.5 VARIES 1.5 5 2"1.75" C6.02 CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-EC2.dwg, 1/5/2021 1:54:12 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-EC2 FINAL DRAWING - RELEASED FOR CONSTRUCTION EROSION & SEDIMENT CONTROL DETAILS N/A 11.13.20201 REVS PER CITY/COUNTY/NCDOT COMMENTS CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:16:27 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C7.00 ROAD IMPROVEMENTGRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. PLAN CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R GENERAL NOTES: 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.ALL DIMENSIONS GIVEN ARE TO THE FACE OF CURB UNLESS NOTED OTHERWISE. 3.PATCHING AND LEVELING MAY BE REQUIRED PRIOR TO RESURFACING THE ROAD. LONG FERRY ROAD ROAD WIDENING LEGEND 1"=30' EXISTING FRONT CREEK DRIVE (ASSUMED 100' WIDTH PUBLIC R/W) NO RECORD FOUND ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) COMPACTED SUBGRADE FULL DEPTH PAVEMENT SECTION 3" S9.5C ASPHALT SURFACE COURSE 4" I19.0C ASPHALT INTERMEDIATE COURSE 5" B25.0C ASPHALT OR 10" AGGREGATE BASE COURSE 1 11.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS 2 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:16:54 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C7.01 GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LONG FERRY ROAD 1"=30' GENERAL NOTES: 1.ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE OWNER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2.ALL DIMENSIONS GIVEN ARE TO THE FACE OF CURB UNLESS NOTED OTHERWISE. 3.PATCHING AND LEVELING MAY BE REQUIRED PRIOR TO RESURFACING THE ROAD. PAVEMENT MARKING LEGENDSIGNAGE LEGEND PAVEMENT MARKINGAND SIGNAGE PLAN EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:17:16 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C7.02 GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LONG FERRY ROAD 1"=30' EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) STATIONING PLANALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:17:40 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LONG FERRY ROAD 1"=30' EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL C7.03 EROSION CONTROL ANDDEMOLITION PLAN DEMOLITION LEGENDEXISTING LEGENDEROSION CONTROL LEGEND CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:18:01 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LONG FERRY ROAD 1"=30' EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL C7.04 GRADING PLAN GRADING LEGENDGENERAL NOTES: 1.REFER TO THE CROSS SECTION SHEETS (XS) FOR THE DETAILED GRADING OF THE PROPOSED ROAD IMPROVEMENTS FOR SHOPTON AND DIVER RIVER ROADS. 2.PATCHING AND LEVELING MAY BE REQUIRED PRIOR TO RESURFACING THE ROAD. 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:22:16 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LONG FERRY ROAD 1"=30' EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL C7.05 TRAFFIC CONTROLPLAN SCOPE OF WORK FOR MEDIAN AND TURN LANE IMPROVEMENTS: ·INSTALL TRAFFIC CONTROL MEASURES TO ALLOW FOR MEDIAN AND TURN LANE IMPROVEMENTS. ONE LANE OF TRAFFIC MUST BE MAINTAINED IN BOTH DIRECTIONS OF TRAVEL THROUGHOUT CONSTRUCTION. ·COMPLETE NECESSARY DEMOLITION WORK LOCATED WITHIN THE PROPOSED WORK AREA. REFER TO THE SEPARATE DEMOLITION PLAN FOR THE DEMOLITION NOTES. ·MILL EXISTING PAVEMENT ·INSTALL CONCRETE MEDIAN IN LOCATION SHOWN. ·INSTALL NEW PAVEMENT SECTION WITH EXCEPTION OF FINAL COURSE OF ASPHALT ·LAY FINAL COURSE OF ASPHALT OVER NEW PAVEMENT AS WELL AS MILLED AREA OF EXISTING ASPHALT ·RE-STRIPE ROAD ·REMOVE TRAFFIC CONTROL MEASURES TRAFFIC CONTROL NOTES: ·ALL LANE CLOSURES WILL REQUIRE NIGHT WORK ·WHEN WORKING WITHIN 5' OF TRAVEL LANE THAT LANE IS TO BE CLOSED ·ONLY ONE SIDE OF ROAD CAN BE WORKED ON AT ONE TIME UNLESS APPROVED BY NCDOT SCOPE OF WORK FOR DRIVEWAY TIE INS: NOTE: THE TWO PROPOSED CONNECTIONS TO FREEDOM DRIVE CAN NOT BE MADE AT THE SAME TIME THAT IMPROVEMENTS ARE BEING MADE TO THE EXISTING MEDIAN AND TURN LANES. THE TIE INS MUST BE MADE EITHER BEFORE OR AFTER TO ENSURE THERE IS ADEQUATE ROOM TO CONVEY TRAFFIC. ·INSTALL TRAFFIC CONTROL MEASURES TO ALLOW FOR DRIVEWAY TIE INS. ONE LANE OF TRAFFIC MUST BE MAINTAINED THROUGHOUT CONSTRUCTION. ·COMPLETE NECESSARY DEMOLITION WORK LOCATED WITHIN THE PROPOSED WORK AREA. REFER TO THE SEPARATE DEMOLITION PLAN FOR THE DEMOLITION NOTES. ·MILL EXISTING PAVEMENT ·INSTALL DRIVEWAY CURB AND GUTTER AND INSTALL NEW PAVEMENT SECTION WITH EXCEPTION OF FINAL COURSE OF ASPHALT ·LAY FINAL COURSE OF ASPHALT OVER NEW PAVEMENT AS WELL AS MILLED AREA OF EXISTING ASPHALT. ·STRIPE ROAD AS NECESSARY ·REMOVE TRAFFIC CONTROL MEASURES ROAD WIDENING LEGEND POSTED SPEED LIMIT - 45 MPH EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) POSTED SPEED LIMIT - 45 MPH EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) POSTED SPEED LIMIT - 45 MPH PHASE 1 PHASE 2 PHASE 3 CAT SCALECLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-RW1.dwg, 1/5/2021 2:22:54 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-RW1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C7.06 GRAPHIC SCALE 0 15 30 60 1 inch = 30 ft. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. R LONG FERRY ROAD 1"=30' EXISTING LONG FERRY ROAD (SR 2120) (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) EXISTING FRONT CREEK ROAD (VARIABLE WIDTH PUBLIC R/W) TRUCK MOVEMENT PLANALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF SALISBURY CONSTRUCTION STANDARDS MANUAL 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄ LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY EX. E/P (1.5") MILL(1.5") OVERLAY EL.=716.17OFFSET=28.97' RE/P EL.=716.16OFFSET=29.09' R±12' EXISTING TRAVEL LANE±17' TURN LANE 2'-6" CURB AND GUTTER PER NCDOT STD. 846.01 LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY 1.5" MILL & OVERLAY EX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.33OFFSET=28.75' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=716.79OFFSET=-27.82' LE/P EL.=717.29OFFSET=31.53' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.60OFFSET=11.70' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.50OFFSET=1.06' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 TURN LANE TAPER±4' SHOULDER ±11' EXISTING TURN LANE 10.64' 3:1 MAXIMUM TIE OUT 2'-6" CURB AND GUTTER PER NCDOT STD. 846.01 M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XS-1.dwg, 1/5/2021 2:26:02 PM, Woodard, JonathanLONG FERRY ROADCLIENTREVISIONS N0.DATE PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE 1"=5'/1"=5' DATE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-XS-1 CROSS SECTIONS111.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C7.07 STA. 0+00 THRU STA. 1+00 LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY1.5" MILL & OVERLAYEX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.72OFFSET=-18.23' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.40OFFSET=23.85' R5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 ±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE ±11' TURN L LANETAPER E/P EL.=719.15OFFSET=30.95' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.10OFFSET=0.25' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.98OFFSET=7.43' RSHOULDER 7.18' 2'-6" CURB AND GUTTER PER NCDOT STD. 846.01 3:1 MAXIMUM TIE OUT LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY 1.5" MILL & OVERLAYEX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.82OFFSET=-27.13' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.58OFFSET=27.69' RE/P EL.=718.53OFFSET=33.08' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.73OFFSET=11.28' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.60OFFSET=0.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 11' TURN LANE TAPERTURN LANE TAPER±4.5' SHOULDER 2'-6" CURB AND GUTTER PER NCDOT STD. 846.01 3:1 MAXIMUM TIE OUT LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY 1.5" MILL & OVERLAY EX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.13OFFSET=25.67' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.02OFFSET=-22.48' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.44OFFSET=9.48' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.46OFFSET=0.25' R±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 9.27'TURN LANE TAPER±3.4' SHOULDER E/P EL.=718.98OFFSET=32.96' R±12' EXISTING TRAVEL LANE ±11' TURN LANE 2'-6" CURB AND GUTTER PER NCDOT STD. 846.01 3:1 MAXIMUM TIE OUT M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XS-1.dwg, 1/5/2021 2:26:38 PM, Woodard, JonathanLONG FERRY ROADCLIENTREVISIONS N0.DATE PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE 1"=5'/1"=5' DATE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-XS-1 CROSS SECTIONS111.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C7.08 STA. 1+50 THRU STA. 2+50 LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY 1.5" MILL & OVERLAYEX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.26OFFSET=-14.68' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.45OFFSET=21.57' RE/P EL.=717.86OFFSET=31.75' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.50OFFSET=0.25' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.44OFFSET=4.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 4'±2.5' SHOULDER ±4' SHOULDER±11' TURN LANE 3:1 MAXIMUM TIE OUT LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYEX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.41OFFSET=21.21' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.33OFFSET=-14.97' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.41OFFSET=4.25' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.51OFFSET=0.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 4'±11' TURN L LANE DRIVEWAY TIE IN±3' SHOULDER E/P EL.=717.52OFFSET=55.26' RLONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTIONEX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.20OFFSET=-15.73' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=719.45OFFSET=22.36' RE/P EL.=718.07OFFSET=46.44' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.41OFFSET=5.48' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=720.53OFFSET=0.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 ±3.5' SHOULDER 5.23'±11' TURN L LANE DRIVEWAY TIE IN 2'-6" CURB AND GUTTER PER NCDOT STD. 846.01 3:1 MAXIMUM TIE OUT M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XS-1.dwg, 1/5/2021 2:27:12 PM, Woodard, JonathanLONG FERRY ROADCLIENTREVISIONS N0.DATE PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE 1"=5'/1"=5' DATE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-XS-1 CROSS SECTIONS111.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C7.09 STA. 3+00 THRU STA. 4+00 LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION 1.5" MILL & OVERLAY 1.5" MILL & OVERLAY EX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.38OFFSET=24.00' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.32OFFSET=-14.38' LE/P EL.=716.99OFFSET=31.75' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.45OFFSET=0.25' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.36OFFSET=4.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 4'SHOULDER ±4' SHOULDER±11' TURN LANE 3:1 MAXIMUM TIE OUT LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYPROPOSED END OF FULL DEPTH PAVEMENTFULL-DEPTH PAVEMENT SECTION EX. E/P (1.5") MILL(1.5") OVERLAY EL.=716.88OFFSET=27.65' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.03OFFSET=-14.39' LE/P EL.=716.71OFFSET=31.75' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=718.00OFFSET=0.25' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.89OFFSET=4.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 ±4' SHOULDER±11' TURN LANE±2' SHOULDER 4' 3:1 MAXIMUM TIE OUT LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPPROPOSED CONCRETE ISLANDPROPOSED CONCRETE ISLANDEXISTING RIGHT-OF-WAYEXISTING RIGHT-OF-WAYEX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.71OFFSET=-13.65' LEX. E/P (1.5") MILL(1.5") OVERLAY EL.=716.49OFFSET=29.37' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.66OFFSET=4.25' REX. E/P (1.5") MILL(1.5") OVERLAY EL.=717.77OFFSET=0.25' R±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANE 5" MONOLITHIC CONCRETE ISLAND (KEYED IN-2' WIDE) PER NCDOT STD. 852.01 4'±4' SHOULDER±11' TURN LANE±1.4' SHOULDER PROPOSED END OF FULL DEPTH PAVEMENTE/P EL.=716.38OFFSET=31.75' R3:1 MAXIMUM TIE OUT M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XS-1.dwg, 1/5/2021 2:27:46 PM, Woodard, JonathanLONG FERRY ROADCLIENTREVISIONS N0.DATE PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE 1"=5'/1"=5' DATE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-XS-1 CROSS SECTIONS111.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C7.10 STA. 4+50 THRU STA. 5+50 LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING RIGHT-OF-WAYEX. E/P (1.5") MILL(1.5") OVERLAY EL.=716.59OFFSET=-13.14' LEXISTING EOP±12' EXISTING TRAVEL LANE ±12' EXISTING TRAVEL LANEPROPOSED END OF FULL DEPTH PAVEMENT±19' U-TURN BULB STRIPED MEDIAN ±12' EXISTING TURN LANEE/P EL.=716.58OFFSET=-31.14' L3:1 MAXIMUM TIE OUT ±3' SHOULDER LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPLONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XS-1.dwg, 1/5/2021 2:28:20 PM, Woodard, JonathanLONG FERRY ROADCLIENTREVISIONS N0.DATE PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE 1"=5'/1"=5' DATE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-XS-1 CROSS SECTIONS111.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C7.11 STA. 6+00 THRU STA. 7+00201.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ LONG FERRY ROAD (SEE SHEET C7.02-STATIONING PLAN) ℄EXISTING EOPEXISTING EOPEXISTING RIGHT-OF-WAYM:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-XS-1.dwg, 1/5/2021 2:28:50 PM, Woodard, JonathanLONG FERRY ROADCLIENTREVISIONS N0.DATE PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE 1"=5'/1"=5' DATE 09.24.2020 7-ELEVEN - LONG FERRY ROAD STORE NUMBER: 1047760 CONSTRUCTION DRAWINGS 1215 LONG FERRY ROAD SALISBURY, NORTH CAROLINA 28146 The John R. McAdams Company, Inc. www.mcadamsco.com phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 3430 Toringdon Way Suite 110 Charlotte, NC 28277 PLAN INFORMATION FINAL DRAWING - RELEASED FOR CONSTRUCTION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE:704.414.7472 CPR20000-XS-1 CROSS SECTIONS111.13.2020 REVS PER CITY/COUNTY/NCDOT COMMENTS C7.12 STA. 7+50 N/A CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-D1.dwg, 1/5/2021 2:30:43 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-D1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C8.00 SITE DETAILS · · · N/A CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-D1.dwg, 1/5/2021 2:31:09 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-D1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C8.01 STORM DRAINAGE DETAILS N/A CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-D1.dwg, 1/5/2021 2:32:11 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-D1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C8.02 WATER & SANITARY SEWER DETAILS 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ N/A CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-D1.dwg, 1/5/2021 2:33:11 PM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-D1 FINAL DRAWING - RELEASED FOR CONSTRUCTION C8.03 ROADWAY IMPROVEMENT & PAVEMENT MARKING DETAILS GRAPHIC SCALE 0 5 10 20 1 inch = 10 ft. 1"=10' C9.00 STORMWATER CONTROL MEASURE "A" PLAN VIEW STORMWATER CONTROL MEASURE 'A' CONSTRUCTION SPECIFICATIONS GENERAL NOTES 1.PRIOR TO CONSTRUCTION, ANY DISCREPANCIES IN THE PLANS AND NOTES SHALL BE BROUGHT TO THE DESIGN ENGINEER'S ATTENTION IMMEDIATELY. 2.THE FINAL CERTIFICATION FOR THIS FACILITY WILL INCLUDE A CERTIFICATION BY THE ON-SITE GEOTECHNICAL ENGINEER THAT THE PROJECT WAS CONSTRUCTED PER THE APPROVED PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE ON-SITE GEOTECHNICAL ENGINEER FOR OBSERVATION AND TESTING SUCH THAT THE ON-SITE GEOTECHNICAL ENGINEER CAN CERTIFY THE CONSTRUCTION. 3.ALL CONSTRUCTION ACTIVITY RELATED TO THE PROPOSED STORMWATER MANAGEMENT FACILITY SHALL BE PER THE DETAILS AND SPECIFICATIONS SHOWN IN THESE DRAWINGS. SOILS, COMPACTION, AND OTHER MISCELLANEOUS DETAILS AND SPECIFICATIONS MAY BE MODIFIED PER THE RECOMMENDATIONS OF THE ON-SITE GEOTECHNICAL ENGINEER. HOWEVER, PRIOR TO IMPLEMENTATION, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATION FROM THESE DESIGN DRAWINGS, INCLUDING SHOP DRAWINGS FOR ANY PROPOSED MODIFICATION. 4.DURING THE INITIAL STAGES OF CONSTRUCTION, THE STORMWATER MANAGEMENT FACILITY MAY BE USED AS A SEDIMENT BASIN FOR EROSION CONTROL PURPOSES. IF SO, THE CONTRACTOR SHALL FOLLOW THE GENERAL CONSTRUCTION SEQUENCE BELOW: 4.1.THE CONTRACTOR SHALL CONSTRUCT THE ENTIRE FACILITY (PERMANENT OUTLET STRUCTURE, DAM, ETC.) WITH THE EXCEPTION OF THE INTERIOR FINE GRADING FOR THE FACILITY. THE INTERIOR FINE GRADING WILL BE CONSTRUCTED ONCE THE EROSION CONTROL PHASE IS COMPLETE. 4.2.THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) SHALL BE CONNECTED TO THE PERMANENT 6"Ø UNDERDRAIN CONNECTION. 4.3.ONCE THE UPSTREAM DRAINAGE AREA IS STABILIZED AND THE EROSION CONTROL INSPECTOR APPROVES THE REMOVAL OF THE SEDIMENT BASIN, THE CONTRACTOR SHALL REMOVE THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) AND CLEAN-OUT THE BASIN. ALL SEDIMENT, TRASH, ETC. SHALL BE DISPOSED OF PROPERLY (I.E. - PLACED IN A LANDFILL) AND NOT STOCKPILED IN AN AREA WHERE WATER QUALITY COULD BE ADVERSELY AFFECTED. 4.4.ONCE THE BASIN IS CLEANED OUT, AND ALL EROSION CONTROL DEVICES REMOVED, THE CONTRACTOR SHALL CONSTRUCT THE INTERIOR GRADING SHOWN ON THIS SHEET. 4.5.ONCE THE GRADING IS COMPLETE, THE CONTRACTOR SHALL REQUEST AN ON-SITE INSPECTION AND AN AS-BUILT SURVEY PRIOR TO INSTALLATION OF THE STORMWATER MANAGEMENT FACILITY PLANTS. IF THE CONTRACTOR PLANTS THE PROPOSED VEGETATION PRIOR TO AN AS-BUILT SURVEY (AND SUBSEQUENT APPROVAL), ANY CHANGES TO THE GRADING / RE-PLANTING OF PLANTS WILL BE AT THE CONTRACTOR'S EXPENSE. 4.6.ONCE THE ENGINEER HAS APPROVED THE AS-BUILT GRADING, THE CONTRACTOR SHALL PLANT THE PROPOSED STORMWATER MANAGEMENT FACILITY PLANTS SHOWN ON THE LANDSCAPE PLAN FOR THE FACILITY. AFTER COMPLETION OF THE PLANTING, THE LANDSCAPE CONTRACTOR SHALL PROVIDE A LETTER TO THE ENGINEER CERTIFYING THAT THE PLANTS HAVE BEEN INSTALLED PER THE APPROVED STORMWATER MANAGEMENT FACILITY PLANTING PLAN. 5.THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE BOTTOM. 6.THE RETAINING WALL IS TO BE A DESIGN-BUILD PROJECT(S) BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED PROFESSIONAL ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALL. 7.THE RETAINING WALL SHALL BE ASSUMED TO BE BACKFILLED WITH OFF-SITE BORROW MATERIAL OR PROCESSED FILL UNLESS CONTRACTOR CAN PROVIDE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER THAT READILY AVAILABLE ON-SITE SOILS CAN BE USED. 8.THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS (BY OTHERS). 9.PRIOR TO CONSTRUCTION, THE ONSITE GEOTECHNICAL ENGINEER SHALL VERIFY THE FILTRATION AND PERMEABILITY ASPECTS OF THE PROPOSED SAND FILTER MATERIALS. SPECIAL ATTENTION SHALL BE PAID TO PREVENT MIGRATION OF FINER SOIL PARTICLES THROUGH UNDERLYING GRAVEL LAYERS. 10.ONCE CONSTRUCTED, THE SAND FILTER SHALL NOT RECEIVE STORMWATER RUNOFF UNTIL THE ENTIRE CONTRIBUTING DRAINAGE AREA TO THE SAND FILTER HAS BEEN COMPLETELY STABILIZED AND SITE CONSTRUCTION IS COMPLETE. 11.PRIOR TO PLACING ANY MEDIA (I.E. UNDERDRAINS, GRAVEL, OR SAND) WITHIN THE SAND FILTER, THE CONTRACTOR SHALL REQUEST AN ONSITE MEETING WITH THE DESIGN ENGINEER TO ENSURE THE UPSTREAM DRAINAGE AREA IS COMPLETELY STABILIZED (I.E. GOOD VEGETATIVE COVER). IF THE CONTRACTOR DECIDES TO PLACE THE MEDIA FOR THE SAND FILTER PRIOR TO APPROVAL FROM THE DESIGN ENGINEER, THEN THE CONTRACTOR SHALL EXCAVATE/REPLACE, AS NECESSARY, THE MEDIA NEEDED FOR THE SYSTEM TO FUNCTION PROPERLY AT HIS / HER EXPENSE SHOULD THE SAND FILTER NOT FUNCTION PROPERLY (I.E. WILL NOT DRAIN DUE TO SEDIMENT DEPOSITION) DUE TO AN UNSTABILIZED UPSTREAM DRAINAGE AREA. 12.ANY REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) ON THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE THE TOP 2"-3" OF THE BERM SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3"-4" ON THE DAM EMBANKMENT. PLEASE NOTE THE STOCKPILED TOPSOIL SHALL BE AMENDED, AS DIRECTED BY A LANDSCAPE PROFESSIONAL, PRIOR TO INSTALLATION ON THE EMBANKMENT. 13.IT IS ANTICIPATED THAT DEWATERING WILL BE NECESSARY IN THE EXCAVATION AREAS (E.G. - EMBANKMENT SUB GRADE, INTERIOR PORTIONS OF THE STORMWATER FACILITY, KEY TRENCH, ETC.). THEREFORE, THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC. NEEDED FOR REMOVAL OF WATER FROM VARIOUS PARTS OF THE STORMWATER FACILITY SITE. DURING PLACEMENT OF FILL WITHIN THESE AREAS, THE CONTRACTOR SHALL KEEP THE WATER LEVEL BELOW THE BOTTOM OF THE EXCAVATION / CONSTRUCTION AREAS. THE MANNER IN WHICH THE WATER IS REMOVED SHALL BE SUCH THAT THE EXCAVATION BOTTOM AND SIDE SLOPES ARE STABLE, WITH NO SEDIMENT DISCHARGED FROM THE SITE (I.E. PUMPED WATER MAY NEED TO BE DIRECTED TO AN APPROVED EROSION CONTROL DEVICE SUCH AS A DIRT BAG (ACF ENVIRONMENTAL), OR ENGINEER APPROVED EQUIVALENT, PRIOR TO DISCHARGE). 14.THE BEDDING MATERIAL FOR THE STORMWATER CONTROL MEASURE SHALL BE SPECIFIED BY THE ON-SITE GEOTECHNICAL ENGINEER. TYPICALLY, A WELL-GRADED GRANULAR MATERIAL WILL BE USED FOR THE BEDDING. PLEASE NOTE THAT IF CONSTRUCTION EQUIPMENT WILL BE OPERATING FOR AN EXTENDED PERIOD OF TIME ON THE BEDDING, THEN THE APPROPRIATE MEASURES (E.G. ENGINEERED FABRIC, STIFF GEOGRID, ETC.) SHALL BE TAKEN TO ENSURE THE INTEGRITY OF THE BEDDING IS NOT COMPROMISED. OUTLET STRUCTURE MATERIAL SPECIFICATIONS 1.THE 15"Ø RCP OUTLET BARREL SHALL BE CLASS III RCP, MODIFIED BELL AND SPIGOT, MEETING THE REQUIREMENTS OF ASTM C76-LATEST. THE PIPES SHALL HAVE CONFINED O-RING RUBBER GASKET JOINTS MEETING ASTM C-443-LATEST. THE PIPE JOINTS SHALL BE TYPE R-4. 2.THE STRUCTURAL DESIGN FOR THE 4' X 4' (INTERNAL DIMENSIONS) RISER BOX WITH EXTENDED BASE SHALL BE BY OTHERS. PRIOR TO ORDERING THE STRUCTURES, THE CONTRACTOR SHALL PROVIDE, TO THE DESIGN ENGINEER FOR REVIEW, SHOP DRAWINGS AND SUPPORTING STRUCTURAL CALCULATIONS SEALED BY A P.E. REGISTERED IN NORTH CAROLINA DEMONSTRATING THE PERTINENT VERTICAL LOADS ARE SUPPORTED BY THE CONCRETE RISER STRUCTURE. 3.THE RISER BOX OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS 16" ON CENTER. STEPS SHALL BE PROVIDED ON THE INNER WALL OF THE RISER BOX. STEPS SHALL BE IN ACCORDANCE WITH NCDOT STD. 840.66. SEE SHEET C9.02. PLEASE REFER TO SHEET C9.02 FOR LOCATION OF THE RISER STEPS. 4.THE CONCRETE ANTI-FLOTATION BLOCKS SHALL BE PRECAST AS THE EXTENDED BASE OF THE RISER BOX DURING FABRICATION. THE PRECAST BASE SHALL BE INCLUDED AS PART OF THE SHOP DRAWINGS THAT WILL BE SUBMITTED TO THE ENGINEER FOR REVIEW (SEE ITEM 2 ABOVE). IN LIEU OF A PRE-CAST BASE, THE CONTRACTOR MAY OPT TO CAST-IN-PLACE THE ANTI-FLOTATION BLOCK IN THE FIELD. HOWEVER, PRIOR TO CONSTRUCTING THE CAST-IN-PLACE BASE, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR REVIEW DENOTING THE FOLLOWING: A.STEEL REINFORCEMENT B.THE CONNECTION MECHANISM TO JOIN THE ANTI-FLOTATION BLOCK WITH THE RISER SECTION 5.IF THE ANTI-FLOTATION BLOCK IS PRECAST AS PART OF THE RISER BASE SECTION, THE ENTIRE PRECAST RISER BOX STRUCTURE SHALL HAVE A SHIPPING WEIGHT OF 14,316 LBS. THE STRUCTURE WEIGHT SHALL BE THE SHIPPING WEIGHT AND SHALL BE DETERMINED BY SUBTRACTING THE WEIGHT OF THE FACTORY BLOCK OUT FROM THE GROSS STRUCTURE WEIGHT. THIS INFORMATION SHALL BE SHOWN ON THE SHOP DRAWINGS SUBMITTED TO THE ENGINEER FOR REVIEW. IF THE CONTRACTOR OPTS TO CAST-IN-PLACE THE ANTI-FLOTATION BLOCK, THE CONTRACTOR SHALL ENSURE THE WEIGHT OF THE ENTIRE RISER STRUCTURE IS EQUAL TO THE MINIMUM LISTED ABOVE. 6.THE RISER BOX JOINTS SHALL BE SEALED USING BUTYL RUBBER SEALANT CONFORMING TO ASTM-C990-LATEST. IF NECESSARY, THE CONTRACTOR SHALL INCORPORATE A WATERSTOP INTO THE RISER BOX JOINT TO ENSURE A WATERTIGHT CONNECTION. THE CONTRACTOR SHALL PARGE JOINTS ON BOTH THE INSIDE AND OUTSIDE WITH NON-SHRINK GROUT. 7.PRIOR TO ORDERING, THE CONTRACTOR SHALL SUBMIT TRASH RACK SHOP DRAWINGS TO THE ENGINEER FOR REVIEW. CONTRACTOR SHALL ENSURE THAT AN ACCESS HATCH IS PROVIDED WITHIN THE TRASH RACK (SEE DETAIL FOR LOCATION) THAT WILL ALLOW FOR FUTURE MAINTENANCE ACCESS. CONTRACTOR SHALL ALSO PROVIDE A CHAIN AND LOCK FOR SECURING THE ACCESS HATCH. NOTE THE ACCESS HATCH SHALL LINE UP WITH THE ACCESS STEPS AFTER INSTALLATION. 8.ALL POURED CONCRETE SHALL MEET THE FOLLOWING SPECIFICATIONS UNLESS OTHERWISE NOTED: -MINIMUM 3000 PSI (28 DAY) -SLUMP = 3" - 5" -ENTRAINED AIR = 5% - 7% PLEASE NOTE NO CONCRETE SHALL BE POURED WHEN THE AMBIENT AIR TEMPERATURES ARE EXPECTED TO BE ABOVE 85°F OR BELOW 40°F. CAST-IN-PLACE CONCRETE SHALL BE "WET CURED" AFTER FINISHING FOR A MINIMUM OF 48 HOURS. 9.GEOTEXTILE FABRIC FOR THE 15"Ø RCP OUTLET BARREL JOINTS SHALL BE MIRAFI 180N OR ENGINEER APPROVED EQUAL (NON-WOVEN FABRIC). ON-SITE GEOTECHNICAL ENGINEER TO APPROVE FABRIC. BERM AND SOIL COMPACTION SPECIFICATIONS 1.PRIOR TO CONSTRUCTION, THE ON-SITE GEOTECHNICAL ENGINEER SHALL IDENTIFY BORROW / FILL AREAS AND VERIFY THEIR SUITABILITY FOR USE WITHIN THE DAM EMBANKMENT. ALSO, THE ON-SITE GEOTECHNICAL ENGINEER SHALL PERFORM STANDARD PROCTORS ON THE PROPOSED BORROW MATERIAL TO ENSURE THAT OPTIMUM MOISTURE CONTENT AND COMPACTION CAN BE ACHIEVED / CONTROLLED DURING CONSTRUCTION. 2.ALL FILL MATERIALS TO BE USED FOR THE DAM EMBANKMENT SHALL BE TAKEN FROM BORROW AREAS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE FILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, WOOD, STONES GREATER THAN 6", AND FROZEN OR OTHER OBJECTIONABLE MATERIAL. THE FOLLOWING SOIL TYPES ARE SUITABLE FOR USE AS FILL WITHIN THE DAM EMBANKMENT AND KEY TRENCH: ML AND CL. 3.FILL PLACEMENT FOR THE EMBANKMENT SHALL NOT EXCEED A MAXIMUM 8" LIFT (UNCOMPACTED). EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. FILL MATERIAL ADJACENT TO ALL SPILLWAY AND DRAINAGE STRUCTURES SHALL BE PLACED IN 4-INCH (UNCOMPACTED) LIFTS AND HAND-COMPACTED TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. 4.ALL FILL SOILS USED IN THE EMBANKMENT CONSTRUCTION SHALL BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM-698). THE FILL SOILS SHALL BE COMPACTED AT A MOISTURE CONTENT WITHIN -1 TO +3 PERCENT OF ITS OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER DURING CONSTRUCTION TO VERIFY THAT THE PROPER COMPACTION LEVEL HAS BEEN REACHED. THE FILL SHOULD BE COMPACTED USING A SHEEPSFOOT TYPE COMPACTOR. IN ORDER TO PREVENT DAMAGE TO THE PIPE, NO COMPACTION EQUIPMENT SHALL CROSS ANY PIPE UNTIL MINIMUM COVER IS ESTABLISHED ALONG THE PIPE. 5.THE DESIGN ENGINEER SHALL BE PROVIDED WITH REPORTS AND CERTIFICATION, BY THE ON-SITE GEOTECHNICAL ENGINEER, THAT THE GEOTECHNICAL ASPECTS OF THE FACILITY HAVE BEEN CONSTRUCTED PER PLAN. THESE REPORTS AND CERTIFICATION WILL BE NEEDED DURING THE AS-BUILT CERTIFICATION PROCESS FOR THIS STORMWATER FACILITY. THEREFORE, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE TESTING AND OBSERVATION WITH THE ON-SITE GEOTECHNICAL ENGINEER. 6.TESTING OF THE NEW FILL MATERIALS SHALL BE PERFORMED TO VERIFY THAT THE RECOMMENDED LEVEL OF COMPACTION IS ACHIEVED DURING CONSTRUCTION. THEREFORE, ONE DENSITY TEST SHALL BE PERFORMED FOR EVERY 2,500 SQUARE FEET OF AREA FOR EVERY LIFT OF FILL OR AS RECOMMENDED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7.TESTING WILL BE REQUIRED ALONG THE 15"Ø RCP OUTLET BARREL AT A FREQUENCY OF ONE TEST PER 25 LF OF PIPE PER VERTICAL FOOT OF FILL OR AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. STATEMENT OF RESPONSIBILITY 1.ALL REQUIRED MAINTENANCE AND INSPECTIONS OF THE STORMWATER MANAGEMENT FACILITIES SHALL BE THE RESPONSIBILITY OF THE OWNER, PER THE EXECUTED OPERATION AND MAINTENANCE AGREEMENT FOR THIS FACILITY. CONSTRUCTION SEQUENCE 1.PRIOR TO CONSTRUCTION, THE OWNER SHALL OBTAIN A LAND DISTURBING (GRADING) PERMIT AND AN "APPROVAL TO CONSTRUCT" FROM ROWAN COUNTY AND ALL OTHER NECESSARY PERMITS FROM APPLICABLE AGENCIES. 2.INSTALL ALL SEDIMENT AND EROSION CONTROL MEASURES PER THE APPROVED SEDIMENT AND EROSION CONTROL PLAN. THE CONTRACTOR SHALL MAINTAIN ALL APPROVED SEDIMENT AND EROSION CONTROL MEASURES THROUGHOUT THE ENTIRE PROJECT, AS REQUIRED. THE CONTRACTOR SHALL RECEIVE APPROVAL FROM THE EROSION CONTROL INSPECTOR, AS REQUIRED BY GOVERNING AGENCIES, PRIOR TO ANY CLEARING. 3.CLEAR AND GRUB AREA WITHIN THE LIMITS OF THE PROPOSED DAM CONSTRUCTION. ALL TREES AND THEIR ENTIRE ROOT SYSTEMS MUST BE REMOVED FROM THE DAM FOOTPRINT AREA AND BACKFILLED WITH SUITABLE SOIL MATERIAL. THE BACKFILLED AREAS SHALL BE COMPACTED TO THE SAME STANDARDS AS THE DAM EMBANKMENT. THE REMAINING AREA OF THE EMBANKMENT SHALL BE STRIPPED TO A SUITABLE DEPTH AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. ANY RESIDUAL SOILS TO BE LEFT IN PLACE MUST BE WELL SCARIFIED TO PROMOTE BONDING OF THE NEW EMBANKMENT FILL. NO EMBANKMENT MATERIAL SHALL BE PLACED FOR THE DAM OR KEY TRENCH UNTIL APPROVAL OF THE DAM SUBGRADE / TRENCH IS OBTAINED FROM THE ON-SITE GEOTECHNICAL ENGINEER. 4.EXCAVATE FOR THE NEW KEY TRENCH ALONG THE CENTERLINE OF THE PROPOSED DAM EMBANKMENT. THE TRENCH SHALL EXTEND A MINIMUM OF 5 FT BELOW EXISTING GRADE OR 2 FT BELOW THE CONCRETE CRADLE AND SHALL HAVE A MINIMUM BOTTOM WIDTH OF 5 FEET. THE KEY TRENCH SIDESLOPES SHALL BE A MINIMUM OF 1:1 (H:V). THE KEY TRENCH SHALL BE COMPACTED TO THE SAME SPECIFICATION LISTED IN ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." DEPENDING UPON ON-SITE SOIL CONDITIONS ENCOUNTERED DURING EXCAVATION, THE ON-SITE GEOTECHNICAL ENGINEER MAY VARY THE DEPTH AND DIMENSIONS OF THE KEY TRENCH AS DEEMED NECESSARY. THE ON-SITE GEOTECHNICAL ENGINEER SHALL RETAIN DOCUMENTATION OF ANY VARIATION FOR FUTURE AS-BUILT SUBMITTALS TO THE NCDEQ. 5.BEGIN PLACEMENT OF BACKFILL WITHIN THE KEY TRENCH. THE KEY TRENCH SHALL BE COMPACTED TO THE SPECIFICATIONS LISTED ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." THE KEY TRENCH SHALL BE TESTED PER THE SPECIFICATIONS LISTED IN THAT SECTION. 6.PRIOR TO INSTALLATION, SUBGRADE CONDITIONS ALONG THE SPILLWAY PIPES SHOULD BE EVALUATED BY THE ON-SITE GEOTECHNICAL ENGINEER TO ASSESS WHETHER SUITABLE BEARING CONDITIONS EXIST AT THE SUBGRADE LEVEL. SHOULD SOFT OR OTHERWISE UNSUITABLE CONDITIONS BE ENCOUNTERED ALONG THE PIPE ALIGNMENTS, THESE MATERIALS SHOULD BE UNDERCUT AS DIRECTED BY THE GEOTECHNICAL ENGINEER. THE UNDERCUT MATERIALS SHALL BE REPLACED WITH ADEQUATELY COMPACTED STRUCTURAL FILL, LEAN CONCRETE OR FLOWABLE FILL AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7.IN ORDER TO HELP PROTECT THE SOIL SUBGRADE FROM DETERIORATION (DUE TO EXPOSURE, RAINFALL, SEEPAGE, AND RUNOFF) BEFORE THE CRADLE CAN BE POURED, IT IS STRONGLY RECOMMENDED THAT A 3" TO 4" THICK CONCRETE MUD MAT BE POURED OVER THE SUBGRADE ONCE IT IS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE MUD MAT WILL ALSO PROVIDE BEARING FOR THE BLOCKS THAT TEMPORARILY SUPPORT THE SPILLWAY PIPE UNTIL THE CRADLE CAN BE POURED. THE METHOD OF BLOCK SUPPORT FOR THE PIPE PROPOSED BY THE CONTRACTOR SHOULD BE SUBMITTED TO THE JOHN R. McADAMS COMPANY FOR REVIEW. 8.BEGIN CONSTRUCTION OF THE NEW EMBANKMENT. FILL MATERIALS SHALL BE PLACED IN MAXIMUM 8" THICK LIFTS PRIOR TO COMPACTION, UNLESS DIRECTED OTHERWISE BY THE ON-SITE GEOTECHNICAL ENGINEER. FILL LIFTS SHALL BE CONTINUOUS OVER THE ENTIRE LENGTH OF FILL. IF IT IS NECESSARY, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO FINAL GRADE IN ORDER TO ACHIEVE PROPER COMPACTION. 9.AS CONSTRUCTION OF THE EMBANKMENT MOVES FORWARD, IT WILL BE NECESSARY TO INSTALL THE CONCRETE CRADLE. THIS MAY BE CONSTRUCTED USING ONE OF THE FOLLOWING METHODS: 9.1.IF THE PROPOSED STRUCTURAL FILL MATERIAL IS UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN THE STRUCTURAL FILL SHOULD BE INSTALLED AND COMPACTED UP TO THE TOP OF CONCRETE CRADLE ELEVATION. ONCE THE STRUCTURAL FILL REACHES THE NEXT DOWNSTREAM JUNCTION BOX OR HEADWALL AND IS COMPACTED TO THE ELEVATION OF THE TOP OF THE CONCRETE CRADLE, EXCAVATE THE CONCRETE CRADLE TRENCH PER THE PROVIDED DETAILS AND CONSTRUCT THE CONCRETE CRADLE AS PER THE PROVIDED CONCRETE CRADLE DETAIL. 9.2.IF THE PROPOSED STRUCTURAL FILL IS NOT UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN PRIOR TO CONSTRUCTING THE STRUCTURAL FILL EMBANKMENT, THE FORMWORK FOR THE CONCRETE CRADLE SHOULD BE INSTALLED ON EXISTING GROUND AND / OR THE MUD MAT. THE CONCRETE CRADLE SHALL BE CONSTRUCTED PER THE PROVIDED DETAILS. 10.INSTALL RISER / BARREL ASSEMBLY, ALONG WITH THE EMERGENCY DRAIN SYSTEM. THE DRAIN VALVE LOCATED WITHIN THE RISER BOX SHALL BE KEPT OPEN UNTIL AN AS-BUILT CERTIFICATION HAS BEEN COMPLETED BY THE ENGINEER AND AN APPROVAL TO IMPOUND HAS BEEN ISSUED BY ALL APPLICABLE AGENCIES. 11.INSTALL 15" RCP OUTLET BARREL SPILLWAY FILTER FROM THE DETAILS SHOWN ON SHEET C9.03. 12.CONSTRUCT EMBANKMENT PER SPECIFICATIONS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS" AND REQUIREMENTS OF THE ON-SITE GEOTECHNICAL ENGINEER. ALL CHARACTERISTICS OF THE EMBANKMENT FILL MATERIAL SHALL MEET THE STANDARDS SET FORTH IN "BERM AND SOIL COMPACTION SPECIFICATIONS", INCLUDING COMPACTION AND MOISTURE REQUIREMENTS. IF NECESSARY TO ACHIEVE PROPER COMPACTION, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO PROPER FINAL GRADE. ANY HAND COMPACTION ACTIVITIES AROUND SPILLWAY OR DRAIN STRUCTURES SHALL BE CONDUCTED IN 4-INCH LOOSE LIFTS AND BE TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. ALL COMPACTION AND MOISTURE TESTING SHALL BE CARRIED OUT AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER AND AS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS". 4.UPON COMPLETION OF DAM EMBANKMENT, PROMPTLY STABILIZE AND SEED DAM EMBANKMENT PER SEEDING SCHEDULE. 5.SCHEDULE A FINAL AS-BUILT INSPECTION AND AS-BUILT SURVEY WITH THE ENGINEER. AN AS-BUILT INSPECTION SHOULD BE SCHEDULED A MINIMUM OF 60 DAYS BEFORE A PERMIT TO IMPOUND IS REQUIRED. ANY COMMENTS OR DEFICIENCIES IN THE DAM CONSTRUCTION MUST BE CORRECTED TO THE SATISFACTION OF THE ENGINEER AND OWNER BEFORE CERTIFICATION SHALL BE GRANTED. UPON FINAL APPROVAL FROM NCDEQ, CLOSE THE 8"Ø BOTTOM DRAIN VALVE IN THE RISER BOX AND BEGIN IMPOUNDING WATER. NO WATER SHALL BE IMPOUNDED BEFORE AN APPROVAL TO IMPOUND IS ISSUED FROM NCDEQ. PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE AUG 25 - OCT (BEST)BERMUDA SOD 200 LBS/AC FEB - APR 15 (POSSIBLE) SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 4,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 1000 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE INSPECT AND REPAIR MULCH FREQUENTLY. REFERTILIZE IN LATE WINTER OF THE FOLLOWING YEAR; USE SOIL TESTS OR APPLY 150 LB/AC 10-10-10 FERTILIZER. MOW REGULARLY TO A HEIGHT OF 2-4 INCHES. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM. STORMWATER CONTROL MEASURE 'A' PLAN VIEW 1" = 10' PRE-TREATMENT SAND FILTER APERMANENT DA M CROSS SECTION A-AACLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-SWA.dwg, 1/15/2021 7:25:35 AM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-SWA FINAL DRAWING - RELEASED FOR CONSTRUCTION E X I S T I N G F RO N T C R E E K RO A D ( V A R I A B L E W I D T H P U B L I C R /W ) 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ N / A C9.01 STORMWATER CONTROL MEASURE "A" DETAILS PERMANENT DAM CROSS SECTION A-A N.T.S. 15"Ø RCP INV. OUT EL. = 699.15 NOTES: 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3-INCHES OF THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3- TO 4-INCHES ON THE DAM EMBANKMENT. CONCRETE ANTI-FLOTATION BLOCK CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON-SHRINK GROUT A DOUBLE LAYER OF NON-WOVEN GEOTEXTILE FABRIC SHALL BE PLACED AROUND EACH JOINT OF 15"Ø O-RING RCP BARREL IN 2' WIDE STRIPS CENTERED ON JOINT. 43 LF CLASS III 15"Ø O-RING RCP (ASTM C76-LATEST) @ 4.42% FLOW TOP OF DAM EL. = 706.50 WQV STORM EL. = 704.13 15"Ø CLASS III O-RING RCP INV. = 699.15 APPROXIMATE LOCATION OF EXISTING GROUND 100-YEAR STORM EL. = 705.48 TRASH RACK (SEE DETAIL SHEET C9.02) 1" THICK JOINT FILLER MATERIAL NOTE: PRIOR TO CONSTRUCTION, THE ONSITE GEOTECHNICAL ENGINEER SHALL VERIFY THE FILTRATION AND PERMEABILITY ASPECTS OF THE PROPOSED SAND FILTER MATERIALS. SPECIAL ATTENTION SHALL BE PAID TO PREVENT MIGRATION OF FINER SOIL PARTICLES THROUGH UNDERLYING GRAVEL LAYERS. MATERIAL SPECIFICATIONS/ TEST METHOD SIZE NOTES SAND CLEAN AASHTO-M-6 OR ASTM-C-33 CONCRETE SAND 0.02" TO 0.04"SAND SUBSTITUTIONS SUCH AS DIABASE AND GRAYSTONE #10 ARE NOT ACCEPTABLE. NO CALCIUM CARBONATE OR DOLOMITIC SAND SUBSTITUTIONS ARE ACCEPTABLE. NO "ROCK DUST" CAN BE USED FOR SAND. UNDERDRAIN GRAVEL AASHTO-M-43 0.375" TO 0.75" GEOTEXTILE FILTER FABRIC ASTM-D-4833 (PUNCTURE STRENGTH-125LB) ASTM-D-4632 (TENSILE STRENGTH-300LB) 0.08" THICK EQUIVALENT OPENING SIZE OF #80 SIEVE MUST MAINTAIN 125 GPM PER SQ. FT. FLOW RATE. GEOTEX 117F - WOVEN MONOFILAMENT GEOTEXTILE OR APPROVED EQUIVALENT. UNDERDRAIN PIPING F 758, TYPE PS 25 OR AASHTO-M-252 6" SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC 3/8" PERFORATIONS @ 6" ON CENTER, 4 HOLES PER ROW. MINIMUM OF 4" OF GRAVEL OVER PIPES EACH OBSERVATION WELL/CLEANOUT SHALL INCLUDE THE FOLLOWING: 1.FOR AN UNDERGROUND FLUSH MOUNTED OBSERVATION WELL/CLEANOUT, PROVIDE A TUBE MADE OF NON-CORROSIVE MATERIAL, SCHEDULE 40 OR EQUAL, AT LEAST THREE FEET LONG WITH AN INSIDE DIAMETER OF AT LEAST 6 INCHES. 2.THE TUBE SHALL HAVE A FACTORY ATTACHED CAST IRON OR HIGH IMPACT PLASTIC COLLAR WITH RIBS TO PREVENT ROTATION WHEN REMOVING SCREW TOP LID. THE SCREW TOP LID SHALL BE CAST IRON OR HIGH IMPACT PLASTIC THAT WILL WITHSTAND ULTRAVIOLET RAYS. *ABOVE DETAIL PROVIDED AS SCHEMATIC SCREW TOP P.V.C. WELL CAP ONLY N.T.S. EL. 704.13 EL. 703.00 EL. VARIES 1" MIN. EL. 702.00 19" MIN 12" 7" MIN 14" PONDING DEPTH SAND FILTER MATERIAL SPECIFICATIONS SAND FILTER CROSS SECTION CLEANOUT DETAIL N.T.S.N.T.S. 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE (PER AASHTO M252)WOVEN GEOTEXTILE FILTER FABRIC 6"Ø SOLID SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC PIPE SEAL GASKET PANELLA TYPE CLEANOUT WITH COUNTERSUNK HEAD SCREW TOP LID* FINISHED GRADE SAND MEDIA NON-WOVEN GEOTEXTILE FILTER FABRIC WASHED #57 STONE OR APPROVED EQUIVALENT 1 2 1 2 FLOW TO OUTLET STRUCTURE 6" MIN #57 WASHED STONE TOP OF SAND MEDIA = 703.00 1% MINIMUM SLOPE 2 FT SAND FILTER PROFILE VIEW N.T.S. RIPRAP BERM NCDOT CLASS 'B' RIPRAP D50 = 8" PROPOSED GRADE THE UNDERDRAIN COLLECTION SYSTEM SHOULD BE EQUIPPED WITH 6"Ø MINIMUM PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC. PERFORATIONS SHALL BE PER AASHTO M278 FOR PVC PIPE, AASHTO M252 DOUBLE WALL HDPE PIPE, OR BE 3 8-INCH IN DIAMETER SPACED 3 INCHES ON CENTER ALONG 2 LONGITUDINAL ROWS THAT ARE SPACED 90° APART. THE PIPES SHALL HAVE A MINIMUM SLOPE OF 0.50% AND A MAXIMUM SPACING OF 10 FEET ON CENTER. TOP OF RIPRAP BERM ELEV = 705.00 SAND-BASED BERMUDA SOD TO BE INSTALLED IN THE PRETREATMENT AREA FILTER BLANKET TO BE INSTALLED BETWEEN THE RIP RAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (#57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT 6"Ø SOLID WALL PVC CLEANOUTS (TYP.) SHALL HAVE A SECURELY FASTENED WATERPROOF CAP AND BE A MINIMUM OF 3" ABOVE THE SAND LAYER. THE CLEANOUTS SHALL BE CONNECTED TO THE 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPES WITH A WYE-SECTION. FILTER MEDIA (SEE CROSS SECTION AND SPECIFICATIONS PROVIDED) 6"Ø @ 0.50% PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. USE A FILTER FABRIC WITH A LAYER OF WASHED #2 STONE ON TOP. FILTER FABRIC TOP OF MEDIA = 703.00 THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. USE A FILTER FABRIC WITH A LAYER OF WASHED #2 STONE ON TOP. TOP OF RISER EL. = 705.00 15"Ø RCP TOP OF PIPE = 700.61 1 3 5 FT COMPACTED BERM SECTION (SEE BERM AND SOIL COMPACTION SPECIFICATIONS ON SHEET C9.00) PROPOSED GRADE 5 FT. WIDE MINIMUM KEY TRENCH (SEE BERM AND SOIL COMPACTION SPECIFICATIONS, DETAIL SHEET C9.00) KEY TRENCH TO BE PROVIDED PER THE DIRECTION OF THE SITE GEOTECHNICAL ENGINEER 2.0' (MIN) CONCRETE CRADLE (SEE DETAIL ON SHEET C9.03) SPILLWAY FILTER (SEE DETAIL SHEET C9.03) 15" CLASS III O-RING RCP INVERT EL. = 697.25 ENDWALL PER NCDOT STD. 700.25 (SEE DETAIL ON SHEET C9.02) VELOCITY DISSIPATOR NCDOT CLASS 'A' RIPRAP MINIMUM DIMENSIONS 5'L X 3.3'W X 12" THICK D50 = 3" TO BE LINED WITH GEOTEXTILE FABRIC OR EQUIVALENT (SEE DETAIL SHEET C9.03) NOTES: 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3-INCHES OF THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3- TO 4-INCHES ON THE DAM EMBANKMENT. CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-SWA.dwg, 1/15/2021 7:27:39 AM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-SWA FINAL DRAWING - RELEASED FOR CONSTRUCTION CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR, SEE DETAIL SHEET C9.02) 10' WIDE EMERGENCY SPILLWAY 1 01.06.2021 REVS PER CITY/ROWAN/NCDOT/NCDEQ BERM IS NOT USED FOR MAINTENANCE ACCESS. REFER TO SHEET C9.00 FOR ACCESS RETAINING WALL. DESIGN ANDPERMITTING BY OTHERS BACKFILL SHALL BE PER RETAININGWALL DESIGN PIPE PENETRATION MAY BE REQUIRED BASED ON FINAL RETAINING WALL DESIGN AND PROPOSED LOCATION OF LEVELING BLOCK THAT MAY BE PLACEDABOVE OR BELOW CULVERT N / A C9.02 STORMWATER CONTROL MEASURE "A" DETAILS MAINTENANCE ACCESS STEPS N.T.S. PERMANENT OUTLET STRUCTURE DETAILS N.T.S. N.T.S. RISER TRASH RACK DETAIL NOTES: 1.ALL REBAR TO BE #4 REBAR. 2.ALL REBAR AND ANGLES TO BE HOT-DIPPED GALVANIZED AND BE PROVIDED WITH AN EPOXY COATING. 3.THE HOT-DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISER WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4.CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5.CONTRACTOR SHALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE COLLAR. 6.ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. N.T.S. CONCRETE COLLAR DETAIL FRONT VIEW SIDE VIEW PROVIDE TRASH RACK ACROSS WEIR CONCRETE ANTI-FLOTATION BLOCK CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON-SHRINK GROUT CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR, SEE DETAIL) 15"Ø O-RING RCP PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 15"Ø O-RING RCP INVERT EL. = 701.30 CONCRETE ANTI-FLOTATION BLOCK FLOW TOP OF RISER EL. = 705.00 15"Ø O-RING RCP FLOW 15"Ø O-RING RCP CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR, SEE DETAIL ) 12" 0.50' 7.35 PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 15"Ø O-RING RCP 1" THICK JOINT FILLER MATERIAL CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. AND SHALL LINE UP WITH ACCESS HATCH. CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. AND SHALL LINE UP WITH ACCESS HATCH. 5.85' 7.00'5.00' 1.00' 1.00' 7.00' 5'1.00'1.00' N.T.S. RISER JOINT CONNECTION DETAIL 3.0" 1 2"Ø GRADE 8 STAINLESS STEEL CONCRETE LAG SCREW 12" X 4" X 1 2" GALVANIZED STEEL STRAP (4 PER RISER JOINT) 6" NOTES: 1. CONCRETE ANTI-FLOTATION BLOCK TO BE PROVIDED WITH MINIMUM TEMPERATURE AND SHRINKAGE STEEL REINFORCEMENT. 2. TRASH RACKS NOT SHOWN FOR CLARITY. 3. THE NUMBER OF GUIDES FOR THE VALVE STEM SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE VALVE STEM MUST BE OPERABLE FROM THE TOP OF THE RISER VIA THE HANDWHEEL WITH AN INSIGNIFICANT AMOUNT OF PLAY IN THE VALVE STEM. 4. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5-FT FROM THE RISER. 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE @ 0.50% SLOPE (MIN.) (PER AASHTO M252) FROM SAND FILTER (TYP.) 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE (PER AASHTO M252)FROM SAND FILTER 6"Ø PERFORATED SCHEDULE 40 OR SDR 35 SMOOTH WALL PVC UNDERDRAIN PIPE (PER AASHTO M252)FROM SAND FILTER CONTRACTOR SHALL TIE SKIMMER PIPE INTO OPENING DURING CONSTRUCTON 4' OUTLET ENDWALL DETAILS N.T.S. CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-SWA.dwg, 1/15/2021 7:29:00 AM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-SWA FINAL DRAWING - RELEASED FOR CONSTRUCTION N / A C9.03 STORMWATER CONTROL MEASURE "A" DETAILS 1" THICK JOINT FILLER MATERIAL 15"Ø O-RING RCP 15"Ø O-RING RCP CONCRETE ANTI-FLOTATION BLOCK 1" THICK JOINT FILLER MATERIAL CONCRETE ANTI-FLOTATION BLOCK FLOW FLOW 1" THICK JOINT FILLER MATERIAL CONCRETE COLLAR (SEE DETAIL SHEET C9.02) NOTES: 1. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5-FT FROM THE RISER. TOP VIEW SIDE VIEW N.T.S. RISER BARREL/CRADLE CONNECTION DETAIL SPILLWAY FILTER DETAIL NO. 67 WASHED STONE ENCASED IN NON-WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) 1' MIN. 1' MIN. ENDWALL PER NCDOT STD. 838.80 15"Ø RCP FLOW PROPOSED GRADE 15"Ø RCP 4'-0" NO. 67 WASHED STONE ENCASED IN NON-WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) 17.5" O.D. 7'-7" ENDWALL PER NCDOT STD. 838.80 NOTE: 4" WEEPHOLES TO BE PROVIDED WITH VARMIT GUARD ON DOWNSTREAM SIDE AND GALVANIZED HARDWARE CLOTH ON UPSTREAM SIDE (1 4" MAXIMUM OPENINGS) 3'3' 59" NO. 67 WASHED STONE ENCASED IN NON-WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) ENDWALL PER NCDOT STD. 838.80 (2) 4" PERFORATED, CORRUGATED HDPE PIPE (DOUBLE-WALL SMOOTH BORE HDPE TYPE "S" OR ENGINEER APPROVED EQUIVALENT) (2) 4" PERFORATED, CORRUGATED HDPE PIPE (DOUBLE-WALL SMOOTH BORE HDPE TYPE "S" OR ENGINEER APPROVED EQUIVALENT) (2) 4" PERFORATED, CORRUGATED HDPE PIPE (DOUBLE-WALL SMOOTH BORE HDPE TYPE "S" OR ENGINEER APPROVED EQUIVALENT) 6" MIN. NOTES: 1.A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR ENGINEER APPROVED EQUIVALENT 2.HAVILAND DRAINAGE PRODUCTS 4" ALUMINUM ANIMAL GUARD ITEM NUMBER 40160420 (OR ENGINEER APPROVED EQUIVALENT) TO BE INSTALLED AT OUTLET OF 4" HDPE PIPES. 15"Ø RCP N.T.S. OUTLET BARREL VELOCITY DISSIPATOR PLAN SECTION A-A NOTES: 1.A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT 24" CONCRETE CRADLE DETAIL N.T.S. 18" (TYP.) 3" COVER (MIN.) TO OUTSIDE OF #3 TIE BAR (TYP.) 18" C/C (TYP.) 3" FROM BOTTOM OF CRADLE TO CENTER OF #6 REBAR #6 REBAR (GRADE 60) #3 REBAR TIES (U-BARS) SPACED AT 10 FT. ON CENTER 1. IF OPTION 9.1 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE SHOWN ON SHEET C9.00, THEN BRING GRADE OF DAM EMBANKMENT TO SPRINGLINE OF PIPE ELEVATION. IF OPTION 9.2 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE, THEN CONSTRUCT FORMWORK FOR CONCRETE CRADLE ON EXISTING GRADE. 2. IF OPTION 9.1 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE SHOWN ON SHEET C9.00, THEN EXCAVATE TRENCH FOR CRADLE AND BARREL PER DIMENSIONS ON DRAWINGS. IF OPTION 9.2 IS CHOSEN FROM NOTE 9 OF THE CONSTRUCTION SEQUENCE, PROCEED TO STEP 3 BELOW. 3. PLACE REINFORCING STEEL AND JOINT FILLER MATERIAL PER DRAWINGS. ALL REINFORCING STEEL SHALL HAVE A MINIMUM OF 3" OF CONCRETE COVER (INCLUDING TIES). 4. PLACE BARREL PIPE ON CONCRETE BLOCKS TO GRADE. CONTRACTOR SHALL WRAP JOINTS WITH 2-FT WIDE STRIPS OF FABRIC AT THIS STEP. 5. POUR CONCRETE FOR CRADLE FOR EACH SECTION FROM ONE SIDE OF THE TRENCH. ALLOW CONCRETE TO FILL ENTIRE AREA UNDER PIPE AND PIPE HAUNCHES AS TO LEAVE NO VOIDS UNDER THE PIPE BEFORE POURING ON THE OPPOSITE SIDE OF THE TRENCH. POUR ENTIRE CRADLE AS ONE LIFT (VERTICALLY) PER DRAWINGS. 6. CONCRETE SHALL BE FINISHED "ROUGH" SO AS TO ACHIEVE A MORE ADEQUATE BOND BETWEEN THE CONCRETE IN THE CRADLE AND THE FIRST LIFT OF STRUCTURAL FILL. 7. ALLOW CRADLE TO CURE FOR A MINIMUM OF 7 DAYS BEFORE ANY VIBRATING COMPACTION EQUIPMENT IS USED IN THE VICINITY OF THE BARREL PIPE. NOTES: 1. ALL TIE BARS (U-BARS) ARE #3 (AS LABELED) REBAR (GRADE 60) SPACED AT 10 FT. CENTER TO CENTER ALONG THE LENGTH OF THE CRADLE. 2. MAINTAIN A MIN. COVER OF 3" OF CONCRETE (TO THE OUTSIDE OF THE REBAR) FOR ALL REINFORCEMENT. 3. TRENCH TO BE BACKFILLED IN 4" LIFTS WHEN COMPACTION IS BY HAND. BACKFILL IS IN 6" LIFTS WHEN CONDUCTED BY MACHINE. MINIMUM OF 2 FEET COVER MUST BE PRESENT ON 15"Ø RCP BEFORE DRIVING OVER WITH HEAVY EQUIPMENT. 4. REINFORCED CONCRETE CRADLE MAY BE REPLACED PER RECOMMENDATION FROM THE ON-SITE GEOTECHNICAL ENGINEER. ANY DEVIATION FROM THIS DETAIL SHALL BE SUBMITTED TO AND REVIEWED BY THE DESIGN ENGINEER PRIOR TO IMPLEMENTATION. 5. TESTING SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER. A SLUMP TEST SHALL BE PERFORMED PRIOR TO PLACEMENT OF THE CRADLE. COMPRESSIVE STRENGTH TESTS SHALL BE PERFORMED TO ENSURE COMPLIANCE WITH SPECIFICATIONS LISTED TO THE RIGHT. BARREL PIPE CRADLE MATERIAL SPECIFICATIONS CONCRETE ·COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS (SEE NOTE #5) ·SHALL BE PLACED ON A 2- TO 2.5-INCH SLUMP (SEE NOTE #5) ·APPROVED MIX DESIGN ·4-6% AIR ENTRAINED ·MAXIMUM MIX TO POUR TIME OF 90 MINUTES ·FOUR CYLINDERS SHALL BE PREPARED FOR TESTING FOR EACH LIFT. ONE SHALL BE TESTED AT SEVEN DAYS, TWO AT 28 DAYS, AND THE FOURTH SHALL BE HELD FOR 54 DAYS. ·A MINIMUM OF 3" OF CONCRETE COVER ON ALL STEEL IS REQUIRED (INCLUDING TIES). ·CONCRETE TO BE VIBRATED VERTICALLY. WET CONCRETE SHALL NOT BE MOVED HORIZONTALLY WITH THE VIBRATOR. BARREL PIPE CONCRETE CRADLE CONSTRUCTION SEQUENCE STEEL ·ALL STEEL TO BE GRADE 60. ·ALL STEEL SHALL BE FREE OF RUST OR OTHER DEBRIS THAT MIGHT PREVENT BONDING TO THE CONCRETE. ·ALL STEEL SHALL BE BENT WITH A MINIMUM RADIUS OF 3DB (1.13" FOR #3) AS SHOWN ON THE DRAWINGS. ·THE #6 BARS IN THE CONCRETE CRADLE SHALL BE SPLICED WITH A MINIMUM OVERLAP OF 32". THE SPLICES SHALL BE SPACED SUCH THAT NO TWO SPLICES OCCUR WITHIN THE SAME LENGTH OF PIPE. 15"Ø O-RING RCP 54" MIN 8.00" (MIN.) 13.50" 1 1 (MIN.) 1 1 12" MIN. 5.94" C/C (TYP.) CLIENT REVISIONS PROJECT NO.CPR-20000 FILENAME CHECKED BY JBW DRAWN BY LSE SCALE DATE 09.24.2020 N0.DATE M:\Projects\CroslandSE\CPR-20000\04-Production\Engineering\Construction Drawings\Current Drawings\CPR20000-SWA.dwg, 1/15/2021 7:29:43 AM, Woodard, JonathanThe John R. McAdams Company, Inc. www.mcadamsco.com 3430 Toringdon Way Suite 110 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 Charlotte, NC 28277 7-ELEVEN - LONG FERRY ROADSTORE NUMBER: 1047760CONSTRUCTION DRAWINGS1215 LONG FERRY ROADSALISBURY, NORTH CAROLINA 28146SHEET PLAN INFORMATION C4 STORE HOLDINGS II, LLC 121 WEST TRADE STREET, SUITE 2550 CHARLOTTE, NORTH CAROLINA 28202 PHONE: 704.414.7472 CPR20000-SWA FINAL DRAWING - RELEASED FOR CONSTRUCTION