HomeMy WebLinkAboutWQ0004230_Additional Information Request_20210119ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. DANIEL SMITH
Director
NORTH CAROLINA
Environmental Quality
January 19, 2021
VICTOR PEREZ — GENERAL MANAGER
A PLACE AT THE BEACH III HOMEOWNERS ASSOCIATION, INC.
1904 EAST FORT MACON ROAD
ATLANTIC BEACH, NORTH CAROLINA 28512
Subject: Application No. WQ0004230
Additional Information Request
A Place at the Beach III WWTP
High -Rate Infiltration System
Carteret County
Dear Mr. Perez:
Division of Water Resources' Central and Regional staff has reviewed the application package
received October 22, 2020. However, additional information is required before the review may be
completed. Please address the items on the attached pages no later than the close of business on February
18, 2021.
Please be aware that you are responsible for meeting all requirements set forth in North Carolina
rules and regulations. Any oversights that occurred in the review of the subject application package are
still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items
in Sections A and B, or failure to provide the additional information on or before the above requested date
may result in your application being returned as incomplete.
Please reference the subject application number when providing the requested information. All
revised and/or additional documentation shall be signed, sealed and dated (where needed), with two paper
copies and one electronic copy submitted to my attention at the address below.
If you have any questions regarding this request, please do not hesitate to contact me at (919) 707-
3659 or erickson.saunders@ncdenr.gov. Thank you for your cooperation.
Sincerely,
Erick Saunders, Engineer
Division of Water Resources
cc: Wilmington Regional Office, Water Quality Regional Operations Section (Electronic Copy)
Permit Application File WQ0004230
D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources
512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617
NoarH c oaouNa �
oePxnmem i enmmomenwi auaiN /� 919.707.9000
Mr. Victor Perez
January 19, 2021
Page 2 of 3
A. Application:
1. Section III.1. of the Non -Discharge System Renewal form (FORM: NDSR 01-20) requires a site
map in accordance with 15A NCAC 02T .0105(d) that provides the following information:
a. Legend, north arrow, and scale
b. Distance measurements verifying all setbacks are being met
c. Stormwater drainage controls
d. Location and ownership of property boundaries within 500 feet of the disposal area (including
road/rail right-of-ways)
e. All facility -related structures and fences within the treatment, storage, and disposal areas
f. All habitable residences and places of assembly within 500 feet of all treatment, storage, and
disposal sites
g. Topographic contour intervals not exceeding 10 feet or 25 percent of total site relief
h. Soil mapping units on all disposal sites
i. Location of all wells, streams (ephemeral, intermittent, and perennial), springs, lakes, ponds,
ditches, and other surface drainage features within 500 feet of all waste treatment, storage, and
disposal site(s)
j. Location and identification of each monitoring well (identify any background/upgradient wells)
k. Latitude and longitude coordinates of all monitoring wells (decimal degrees to 6 digits)
1. Location and identification of major components of the waste disposal system
in. Identification of all storage or treatment earthen structures that are part of the permit
n. The wetted perimeter of all irrigation/infiltration fields with field names (named according to the
approved permit)
o. The delineation of compliance and review boundaries
p. 100-year floodplain (if applicable)
The site map submitted does not show the full permitted system, including, but not limited to the
location of the treatment plant, location of the components of the 500,000 gallon stormwater
collection and disposal facility, and the labeling of the rotary distributor infiltration beds. It also
appears that the property lines are outdated on this map. Please submit a map that fits the above
criteria. [15A NCAC 02T .0105(d)]
Section IV. 1. of FORM: NDSR 01-20 requires a listing of all monitoring wells at the facility, along
with their coordinates, gradient to the disposal field, and location in relation to the compliance and
review boundaries for the disposal fields. Please fill out table IV. 1. for the active monitoring wells
on site.
Mr. Victor Perez
January 19, 2021
Page 3 of 3
B. Existing Permit:
1. The facility description for the previous permit includes the following excerpt for a stormwater
collection system:
"the continued operation of a 500,000 gallon stormwater collection and disposal facility consisting
of a 354 GPM wet well pump station with duplex pumps, thirteen full circle impact sprinklers,
approximately 1,260 linear feet of 6-inch subsurface gravity drain pipe, 1,450 linear feet of 8-inch
force main and all related valves, piping and appurtenances;
The regional office indicates that this was put in place for when large storm events would cause a
surge of stormwater that would mix with raw sewage at the original wastewater facility. However,
it is unclear whether the current operations of this stormwater collection system reflect this original
intent. Please provide a narrative about the current operations of this stormwater system, including
any recent maintenance related to the system. This narrative should discuss the relationship of the
stormwater system and the other permitted wastewater treatment and high -rate infiltration disposal
facilities associated with the permit, and whether there is any interactions between these stormwater
and wastewater facilities.