Loading...
HomeMy WebLinkAbout20071995 Ver 1_More Info Received_20110901Strickland, Bev From: Homewood, Sue Sent: Thursday, September 01, 2011 11:56 AM To: Strickland, Bev Subject: FW: Hartley Drive revised Figures Attachments: Fig6 08-24-11.pdf; Fig9 08-24-11.pdf For file 07-1995 Sue Homewood NC DENR Winston-Salem Regional Office Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Voice: (336) 771-4964 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Brandon Phillips [mailto:Brandon. Phil lips@stvinc.com] Sent: Thursday, August 25, 20119:36 AM To: Homewood, Sue Cc: Kit Persiani; Donald H. Arant Subject: Hartley Drive revised Figures Sue, Attached are two revised Figures (Figure 6 and Figure 9) for the Hartley Drive Extension and Widening project for the City of High Point. The relocated Basin #1 is now depicted on Figure 6 as requested. Also, an additional cross section (B to B) has been added to Figure 9 depicting the profile through the relocated Basin #1. Please review these two figures and let me know if you now have sufficient information to revise the Section 401 WQC that was previously issued for the project. Thanks for your attention to this permit revision request. Brandon J. Phillips, C.H.M.M. Senior Environmental Specialist Brandon.phillips(cDstvinc. com ?S r STV1Ralph Whitehead Associates, Inc. 11000 W. Morehead St., Suite 200 1 Charlotte, NC 28208 1 (704) 372-1885 1 (704) 372-3393 (fax) I www.rwhitehead.com I www.stvinc.com Please consider the environment before printing this e-mail. Visit us at our website: http://www.stvinc.com The information contained in this electronic message is intended only for the use of the individual or entity to which it is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law. If the reader of this message is not the intended recipient, you are informed that any dissemination, copying or disclosure of the material contained herein, in whole or in part, is strictly prohibited. If you have received this transmission in error, please notify STV and purge this message. Strickland, Bev From: Homewood, Sue Sent: Thursday, September 01, 2011 11:37 AM To: Strickland, Bev Subject: FW: Hartley Drive revised Figures Attachments: Hartley basin1 grading.pdf Please put in the file 07-1995 Sue Homewood NC DENR Winston-Salem Regional Office Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Voice: (336) 771-4964 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Brandon Phillips jmailto:Brandon. Phillips@stvinc.com] Sent: Tuesday, August 30, 20117:28 AM To: Homewood, Sue Subject: RE: Hartley Drive revised Figures Sue, The Basin #1 grading plan view is attached for your review and approval. Please let me know if you need anything else. Thanks, Brandon J. Phillips, C.H.M.M. Senior Environmental Specialist =1 r From: Homewood, Sue [mailto:sue.homewoodCabncdenr.gov] Sent: Monday, August 29, 2011 11:44 AM To: Brandon Phillips Subject: RE: Hartley Drive revised Figures Brandon, Thanks, these are almost everything I was looking for. The previous permit had the attached grading detail for the 3 detention basins. This is what I need to see for the revised Basin #1 please. Do you have this you can send over via email? Thanks. Sue Homewood NC DENR Winston-Salem Regional Office Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Voice: (336) 771-4964 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Brandon Phillips [mailto:Brandon. PhillipsCa)stvinc.coml Sent: Thursday, August 25, 20119:36 AM To: Homewood, Sue Cc: Kit Persiani; Donald H. Arant Subject: Hartley Drive revised Figures Sue, Attached are two revised Figures (Figure 6 and Figure 9) for the Hartley Drive Extension and Widening project for the City of High Point. The relocated Basin #1 is now depicted on Figure 6 as requested. Also, an additional cross section (B to B) has been added to Figure 9 depicting the profile through the relocated Basin #1. Please review these two figures and let me know if you now have sufficient information to revise the Section 401 WQC that was previously issued for the project. Thanks for your attention to this permit revision request. Brandon J. Phillips, C.H.M.M. Senior Environmental Specialist brandon. phillips(ft tvinc. com STV STV/Ralph Whitehead Associates, Inc. 1000 W. Morehead St., Suite 200 1 Charlotte, NC 28208 (704) 372-1885 1(704) 372-3393 (fax) I www.rwhitehead.com I www.stvinc.com Please consider the environment before printing this e-mail. Visit us at our website: http://www.stvinc.com The information contained in this electronic message is intended only for the use of the individual or entity to which it is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law. If the reader of this message is not the intended recipient, you are informed that any Olssemination, co,)ying or disclosure of the material contained llerei,t, in whole nr in hart, is stric-Ily p,-ohibited. I you have received this transmis: ion in error, ple,-se notify STV and purge this mcsiage. PROJECT REFERENCE NO. 5E1&T NO. 22 2-D iV IN 0.W SHEEP NO . 2 IGN ROAMAY NYDRAIJ cs TOP OF DAM = 813.50' STV / Ralph Whitehead Associates, Inc. ER ENGINEER VARYSLOPEAT 1000 a'act NvAeotl St. Sta. 200 unanott H ?xe2o ? ?"PtNRO? N., OUTLET STRUCTURE CONCRETE TOPR OVIDE PIPE ANTI-SEEP COLLARS „ - \ , .?`2EESSigyyq - ? VfIOTCH COVER , •4 ?? 4.1 1.5' (TVP.) = SEAL 029388 - • FRONTOFCONTROL 3'-0• E • E .? ?' %fp :?VGINE Q STRUCTURE . - , 18.ORIFICE __ _ _ _ _ _ _________ _ _ _ _ _ ____ 1.5 CTYP.) ____ _ rrr irrr 1 0 _ _ _ POND BOTTOM 24' RCP ELEVATION =808.50 INV BOBAO 8'ABC 3.1 (Mq)( OUTLET URE TO PROVIDE DE PIPE ' ) COVER OUTLET PROTECTION 10 (MIN) CLASSW RIPRAP 236 Z5- POFABC=808.75' _ _ _ _ _ _ _ _ _ _ _ _ _ 18' THICK (3:1 MAX) _ _ _ _ 1'MIN. COVER EL .805.00 ' 24' RCP I 4' DUAL?A' RCP 12' I INV 805.50 INV 805.2 DETENTION BASIN #1 OUTLET STRUCTURE DETAIL - (SIDE VIEW) SCOUR HOLE (NOTT08CJ E) LABS 'B' RIPRW. 18' THICK 4'-9' N4 BARS ?4•GD #4 BARS @4.OC ?'ANGLE BRACKET (TOP VIEW) TRASH RACK DETAIL OPENINGALL SIDES THROAT ELEVATION = 810 5 V-NOTCH ELEVATION-8085' 45 N' R.C. DISCHARGE PIPE INV OUT=80 400 A A IV- ORIFICE INV. IN-806.50' .1'-0' (CROSS SECTION) TRASH RACK DETAIL TOREBA I ! POND FOR% NO. Y 72 TONS C' RIP R IC 180 S.Y. FILTER FABRIC (INCLUDES W 4'?/ a E MERGENCYSPILLWAY 3B TONS CLASS, 'Rip RAP 85 S.V. FILTER FABRIC J ELEVATION 812.00 1 POND SLOPES 4:1 (TYR) 3:1 (MAX.) MIN. 5' INSIDE POE EMERGENCY SPILLWAY CHANNEL 8' BASE WITH 3:1 SIDESLOPES CHAIN LINK FENCE (72 WITH DOUBLE GATE (72' HIGH, 12' W\IOE, 24' OPENING) OUTLET STRUCTURE (SEE DETAIL THIS SHEET) INV. OUT=80800 SCOUR HOLE 19 TONS CLASS W RIP RAP 42 S.Y. FILTER FABRIC REPAIR GRAVEL PATH - WITH 8"ABC ' \? +` y ??J1 2-d. 1813 i ' 8C J F _ 8'CONCSLITERCPSIFRONT VIEW) \DDWEL (L=17eW=8'-#O BAR) I \ 1 !\\ ,8135 / / Li_ \V `INV.OUT?((15.20' ( INSURE THAT THE RISER IS TIED #4 BARS "12"E.W. TO THE BASE DETENTION BASIN #1 OUTLET STRUCTURE DETAIL ?B/? ?? =-8(j?\ QO INV IN?oe.50 (aOTTOeOUE) INV. OUT=505.77 J CLASS'B0 TLETPROTECTIONN NOTES: RIP RAP EST. 23TONS 825g2? IB FILTER FABRIC EST 50 S.Y. 1. CLEAN OUT BASIN WHEN SEDIMENT VOLUME REACHES 1 FOOT ABOVE THE BOTTOM ELEVATION. 827 826 2. TO FACILITATE DETERMINATION OF MAINTENANCE CLEAN OUT REQUIREMENT, PLACE MARKER IN THE BASIN INDICATING THE 1 FOOT ELEVATION. 83p 8?q 826 3. CONSTRUCT THE DAM OF MATERIAL SUITABLE FOR AND MEETING ROADWAY EMBANKMENT 831 SPECIFICATIONS. 833 832 / 21C \ 4. BASINS WILL BE INSPECTED WEEKLY AND AFTER RAINFALL EVENTS. NEEDED REPAIRS WILL BE MADE 83S834 Q? IMMEDIATELY. Q 5. REMOVE DEBRIS, TRASH, AND SEDIMENT BUILDUP FROM THE BASIN AS NECESSARY TO MINIMIZE --C -? OURET CLOGGING. 1'. Fj 6. REPAIR AND REVEGETATE ERODED AREAS AS NEEDED. 7. CHECK INLET PIPES AND OUTLETS FOR STRUCTURAL REPAIRS TO CONFIRM THAT THEY ARE 30R-? / OPERATIONAL. 8. MOW AND REMOVE CLIPPINGS TO LIMIT UNWANTED VEGETATION. 19 21 9. SEE SEEDING SPECIFICATIONS ON SHEET EC-2. 10. CONTRACTOR SHALL VERIFY THE GROUNDWATER ELEVATION IN THE FIELD PRIOR TO CONSTRUCTION. CONTRACTOR SHALL INSTALL PERMANENT POND LINER IN ACCORDANCE WITH D e m THE a PROJECT SPECIAL PROVISIONS IF THE GROUNDWATER IS WITHIN TWO FEET OF THE POND BOTTOM ELEVATION DETENTION BASIN #1 GRADING DETAIL av4ANC JR:11E LEGEND PERMANENT PALUSTRINE FORESTED WETLAND CLEARING IMPACT (0.000 AC) PERMANENT PALUSTRINE FORESTED WETLAND FILL IMPACT (0,296 AC) PERMANENT PALUSTRINE FORESTED WETLAND EXCAVATION (0,021 AC) STREAM FILL IMPACT (0 AC9 0 LF) WETLAND BOUNDARY: STREAM BOUNDARY: EROSION CONTROL FENCING LINE: CONSTRUCTION LIMITS: APPLICANT:CITY OF HIGH POINT LOCATION:HARTLEY DRIVE ACTIVITY: ROADWAY EXTENSION COUNTY: GUILFORD/DAVIDSON STATE: NORTH CAROLINA ROUTE: HARTLEY DRIVE DATE: 08/24/11 PROJECT#: 3202000, TASK 400 SCALE: 1" = 80' ----wLe---- PERMANENT PALUSTRINE FORESTED U) WETLAND EXCAVATION IMPACT v +/- 904 SF 0.021 AC I i LAND GG--l, S 30 I i? EROSION CONTROL FENCING LINE Exlstlng R _ ?` ,( pRIV E - H AR?78. 4g 242" W Existing R/W PERMANENT PALUSTRINE FORESTED WETLAND FILL IMPACT +/- 12,890 SF = 0.296 AC HAND F NG ONLY B PROPOSED a 35 BASIN °I 1 q 5 F x Exlstln R -- 7:?-. -- ` c c c / ? I I F ??` ?,l I I 1 ? I ?m I h I Existing R/W PROPOSED BRIDGE ABUTMENT N STREAM 4 Oft 80 ft SCALE STV/RALPH WHITEHEAD ASSOCIATES 1000 W. MOREHEAD ST. SUITE 200 CHARLOTTE, NORTH CAROLINA 28208 HARTLEY DRIVE EXTENSION CITY OF HIGH POINT, NC SITE PLAN (FIGURE 6) PHONE ^: (704) 372-1885 FAX 0: (704) 372-3393 VOLUME OF FILL IN WETLAND CALCULATION AREA OF WETLAND FILL IMPACT = 12,890 SF AVERAGE FILL HEIGHT = 20 FT VOLUME OF FILL = 12,890 SF X 20 FT = 257,800 CF 9,550 CY VOLUME OF EXCAVATION IN WETLAND CALCULATION AREA OF WETLAND EXCAVATION IMPACT = 904 SF AVERAGE EXCAVATION DEPTH =1FT VOLUME OF EXCAVATION = 904 SF X I FT = 904 CF = 34 CY PROPOSED CENTERLINE 19°58' 84°44' 26°75' 830 ft 825 fit 820 ft 815 ft 810 ft- 805 fit 800 ft 830 ft 825 fit 820 ft 815 ft 810 ft - - 805 fit 800 ft POND TOP OF BERM ELEV = 813°50 4:1 EMERGENCY SPILLWAY POND BOTTOM OUTFALL DITCH ELEV = 807°00 CROSS SECTION B-B PROPOSED BASIN #1 26°75' -PROPOSED GRADE 18°63' 3' WETLAND CLEARING IMPACT POND TOP OF BERM ELEV = 813°50 A°\ Oft 20 ft SCALE