HomeMy WebLinkAbout20070010 Ver 2_Emails_20070427Wildberry 07-OOlOv2 Subject: Wildberry 07-001 Ov2 From: Annette Lucas <annette.lucas@ncmail.net> Date: Fri, 27 Apr 2007 13:39:09 -0400 To: Ian McMillan <ian.mcmillan@ncmail.net> Ian, Bullets: This project is being returned due to the failure to provide Item Number 3 requested in your most recent Request for Information Letter sent by the Division of Water Quality on January 30, 2007. This item required you to convert the wet detention pond to an extended detention wetland because of the Nutrient Sensitive Waters (NSW) classification in this watershed. If you submit another application on this project, please be advised that the DWQ will require plan details of each of the proposed level spreaders at a scale of 1" = 50' or larger. These plans must show the locations of the contour lines, flow splitter devices, bypass channels and forebays. That's all! Annette Annette Lucas <annette.lucas(a~ncmail.net> Environmental Engineer III 401 Wetlands Oversight/Express Unit NC Division of Water Quality 1 of 1 4/30/2007 8:48 AM