Loading...
HomeMy WebLinkAbout20201823 Ver 1_1.7.1_MX5694600_20201016_90%DesignSubmittal_20210112GENERAL NOTES BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP PROJECT It I nnATInKI HALIFAX COUNTY �r r B E LLAMY LAKE ROAD ENFIELD, NORTH CAROLINA, 27823 NOTE: LATITUDE/LONGITUDE TO BE VERIFIED BY AS -BUILT SURVEY. x DRAWING INDEX DRAWING NUMBER DRAWING TITLE SHEET NO. REV. PNG-G-027-0001051 COVER SHEET & DRAWING INDEX 01 OF 20 A PNG-G-027-0001052 CIVIL GENERAL NOTES, LEGENDS & ABBREVIATIONS 02 OF 20 A PNG-G-027-0001053 BILL OF MATERIALS 03 OF 20 A PNG-C-027-0001119 ACCESS ROUTE PLAN 04 OF 20 A PNG-C-027-0001120 ALIGNMENT PLAN & PROFILE 05 OF 20 A PNG-C-027-0001121 ALIGNMENT PLAN & PROFILE 06 OF 20 A PNG-C-027-0001122 ALIGNMENT PLAN & PROFILE 07 OF 20 A PNG-C-027-0001123 HDD DETAIL SHEET 1 - FISHING CREEK 08 OF 20 A PNG-C-027-0001124 HDD DETAIL SHEET 2 - FISHING CREEK 09 OF 20 A PNG-C-027-0001125 EAST AND WEST TIE-IN DETAILS 10 OF 20 A PNG-C-027-0001127 OVERALL ES&PC PLAN 11 OF 20 A PNG-C-027-0001128 ES&PC GENERAL NOTES 12 OF 20 A PNG-C-027-0001129 ES&PC PLAN 13 OF 20 A PNG-C-027-0001130 EROSION CONTROL DETAILS 14 OF 20 A PNG-C-027-0001131 EROSION CONTROL DETAILS 15 OF 20 A PNG-C-027-0001132 EROSION CONTROL DETAILS 16 OF 20 A PNG-C-027-0001135 CONSTRUCTION DETAILS 17 OF 20 A PNG-C-027-0001136 CONSTRUCTION DETAILS 18 OF 20 A PNG-C-027-0001140 GEOTECHNICAL BORING LOGS 19 OF 20 A PNG-C-027-0001141 GEOTECHNICAL BORING LOGS 20 OF 20 A 1. INSTALLER SHALL FURNISH ALL MATERIALS NOT PROVIDED BY THE COMPANY (UNLESS OTHERWISE NOTED ON DRAWINGS OR SPECIFICATIONS) INCLUDING EQUIPMENT TRANSPORTATION AND SERVICES, AND PERFORM ALL NECESSARY WORK AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREINAFTER. 2. IT SHALL BE THE RESPONSIBILITY OF THE INSTALLER TO VERIFY ALL DIMENSIONS GIVEN ON THE DRAWINGS. ANY ITEM IN QUESTION SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER PRIOR TO PROCEEDING WITH THE WORK. 3. INSTALLER SHALL BE RESPONSIBLE FOR PROTECTION OF ALL SURROUNDING AREAS. 4. ALL BELOWGROUND WELDS SHALL BE COATED WITH HBE-95 OR SP-2888 PER PERTINENT DUKE NATURAL GAS BUSINESS UNIT (NGBU) DESIGN AND CONSTRUCTION STANDARDS. 5. ALL ABOVEGROUND PIPING TO BE BLASTED TO CORRECT SOCIETY FOR PROTECTIVE COATINGS (SSPC) SURFACE PROFILE. PAINT SYSTEM TO BE UTILIZED SHALL BE PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. 6. UPON BACKFILLING IN AREAS OF ROCK, BURIED PIPE SHALL HAVE 6" OF SAND PAD FILL PLACED AROUND THE PIPE'S CIRCUMFERENCE. 7. PRESSURE TESTING SHALL MEET THE REQUIREMENTS OF THE DUKE NGBU'S PRESSURE TESTING STANDARD, PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. 8. INSTALLER SHALL DEWATER ALL HYDROSTATICALLY TESTED PIPING, USING CLEANING PIGS AS REQUIRED, AND DRY TO A DEWPOINT OF -40 °F PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. CONSTRUCTION NOTES 1. EXISTING OVERHEAD AND BELOWGROUND FACILITIES MAY BE IN THE WORK AREA VICINITY. INSTALLER IS RESPONSIBLE FOR HAVING SUCH FACILITIES LOCATED AND IS RESPONSIBLE FOR MAINTENANCE AND PRESERVATION OF THESE FACILITIES. 2. PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS, INSTALLER IS REQUIRED TO CALL 811 FOR UTILITY LOCATES A MINIMUM OF 72 HOURS PRIOR TO COMMENCEMENT OF WORK. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DELAYS FROM ANY WORK PROVIDED BY OTHER UTILITIES. 3. IF EXISTING UTILITIES OF ANY TYPE ARE ENCOUNTERED IN THE FIELD AND DEEMED TO BE IN CONFLICT WITH INSTALLATION OF FACILITIES, INSTALLER SHALL NOTIFY THE PROJECT MANAGER IMMEDIATELY SO THE CONFLICT MAY BE RESOLVED. 4. WHEN EXISTING DRAINAGE FACILITIES ARE DISTURBED, INSTALLER SHALL PROVIDE AND MAINTAIN TEMPORARY OUTLETS AND CONNECTIONS FOR PRIVATE DRAINS OR SEWERS. RESTORATION OF THESE FACILITIES IS TO BE PERFORMED ONCE CONSTRUCTION IS COMPLETE AND ARE CONSIDERED INCIDENTAL COSTS OF THE PROJECT. 5. ALL DRAWING MEASUREMENTS ARE TO BE TAKEN FROM EXISTING GRADE. FINAL GRADE SHALL BE MATCHED TO SURROUNDING GRADE AS PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. 6. INSTALLER IS TO REMAIN WITHIN CONSTRUCTION WORKING LIMITS. ACCESS TO AREAS OUTSIDE WORKING LIMITS MUST BE COORDINATED WITH THE OWNER OR DUKE NGBU PROJECT MANAGER. 7. ALL EXCESS EXCAVATION, CONSTRUCTION DEMOLITION DEBRIS AND UNSUITABLE MATERIALS THAT DO NOT CONTAIN ASBESTOS SHALL BE REMOVED FROM THE SITE AND PROPERLY DISPOSED. 8. STANDARD SPECIFICATIONS REFERENCED ON THIS SHEET AND CONSTRUCTION PLANS ARE CONSIDERED AS PART OF THE CONTRACT DOCUMENTS. INCIDENTAL ITEMS OR ACCESSORIES NECESSARY TO COMPLETE THIS WORK MAY NOT BE SPECIFICALLY NOTED, BUT ARE CONSIDERED TO BE A PART OF THIS CONTRACT. 9. BEFORE ACCEPTANCE BY THE OWNER AND FINAL PAYMENT, ALL WORK SHALL BE INSPECTED AND APPROVED BY DUKE NGBU OR COMPANY REPRESENTATIVE. FINAL PAYMENT SHALL BE MADE AFTER ALL OF THE INSTALLER'S WORK HAS BEEN ACCEPTED AND APPROVED AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 10. DURING CONSTRUCTION, ALL LOOSE MATERIAL THAT ARE DEPOSITED IN THE FLOW LINE OF GUTTERS, DRAINAGE STRUCTURES, DITCHES, ETC. SUCH THAT THE NATURAL FLOW LINE OF WATER IS OBSTRUCTED, SHALL BE REMOVED AT THE END OF EACH WORK DAY. 11. ALL FIELD TILE ENCOUNTERED DURING CONSTRUCTION SHALL BE EXTENDED TO OUTLET INTO AN EXISTING DRAINAGE WAY. A RECORD OF ALL FIELD TILE FOR ONSITE DRAIN PIPE ENCOUNTERED SHALL BE KEPT BY THE INSTALLER AND TURNED OVER TO THE PROJECT MANAGER UPON COMPLETION OF THE PROJECT. 12. INSTALLER IS REQUIRED TO MAINTAIN A SET OF ISSUED FOR CONSTRUCTION DRAWINGS AND ALL PERMITS AT THE JOB SITE. ANY MODIFICATIONS OR ALTERATIONS TO THE PLANS OR SPECIFICATIONS SHALL BE APPROVED BY THE PROJECT MANAGER. 13. INSTALLER IS SOLELY RESPONSIBLE FOR EXECUTION OF HIS/HER WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND SPECIFICATIONS. INSTALLER IS RESPONSIBLE FOR THE CONSTRUCTION METHODS AND TECHNIQUES, SEQUENCES, TIME OF PERFORMANCE ALL SAFETY PRECAUTIONS. 14. MINIMUM DEPTH OF BURIAL SHALL BE PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. 15. ALL PIPELINES BEING CROSSED ARE TO BE PROTECTED WITH A MINIMUM OF (3) 4 FEET X 18 FEET WOODEN MATS. 16. PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS, FOR OPEN DITCH EXCAVATION, A MINIMUM OF TWO FEET OF SEPARATION SHALL BE MAINTAINED BETWEEN ALL CROSSING STRUCTURES. SEPARATION BETWEEN CROSSING STRUCTURES AND PIPELINES THAT ARE INSTALLED VIA DIRECTIONAL DRILLING METHODS IS AT THE DISCRETION OF ENGINEERING. 17. DURING BACKFILLING, A SIX INCH CROWN SHALL BE PLACED ON ALL DISTURBED AREAS. COMPACTION REQUIREMENTS SHALL BE PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. 18. BOLTS FOR FLANGES TO BE TORQUED PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. CIVIL AND STRUCTURAL NOTES 1. ADDITIONAL EXCAVATIONS BELOW FOOTINGS MAY BE NECESSARY TO REACH UNDISTURBED SOIL. SHOULD THIS OCCUR, THE EXCAVATION SHALL BE BROUGHT TO THE BOTTOM OF THE FOOTING ELEVATION WITH COMPACTED SAND FILL MEETING THE REQUIREMENTS OF MODIFIED PROCTOR COMPACTION TEST (ASTM D1557) TO 95% IN SIX INCH LIFTS. 2. ALL EXPOSED CONCRETE EDGES SHALL HAVE A 1" X 1" 450 CHAMFER. 3. CONCRETE SHALL BE MIXED AND POURED PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. TESTING SHALL CONFORM TO ACI 318. INSTALLER TO SUPPLY ALL CONCRETE AND TESTING. 4. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 SPECIFICATION. STEEL REINFORCING BAR SHALL CONFORM TO ASTM A615 GRADE 60 AND WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. TIE WIRE SHALL CONFORM TO ASTM A82. 5. UNSUITABLE OR EXCESS EARTH SPOIL SHALL BE DISPOSED OF AT AN APPROVED WASTE LOCATION. SOIL BEING TRANSPORTED ONTO THE JOB SITE SHALL BE APPROVED BY EITHER THE PROJECT MANAGER OR CONSTRUCTION MANAGER. 6. ROCKSHIELD OR SIMILAR COMPANY APPROVED PRODUCT MUST BE INSTALLED BETWEEN ALL PIPE AND FITTINGS THAT COME INTO CONTACT WITH CONCRETE. A LAYER OF NON ABRASIVE MATERIAL SUCH AS FRP SHALL BE INSTALLED BETWEEN ALL PIPE SUPPORTS AND PIPING. 7. ALL FIELD BENDING OF REBAR SHALL BE DONE COLD. SOIL EROSION AND SEDIMENT CONTROL NOTES 1. INSTALLER IS TO CONSTRUCT ALL SOIL EROSION AND SEDIMENT CONTROL MEASURES AT THE COMMENCEMENT OF THE PROJECT, PROVIDE MAINTENANCE AND ASSURE EFFECTIVENESS THROUGHOUT THE DURATION OF THE PROJECT. 2. CARE SHALL BE TAKEN TO MINIMIZE DOWNSTREAM SILTATION. RAW BANKS MAY BE SEEDED AND MULCHED TO PREVENT EROSION. 3. ALL SPOILS INCLUDING ORGANIC SOILS, VEGETATION AND DEBRIS SHALL BE REMOVED FROM THE SITE AND PROPERLY DISPOSED OF IN SUCH A MANNER AS TO NOT ERODE INTO ANY BODY OF WATER OR WETLAND. 4. SILT FENCING SHALL BE PLACED WHERE NECESSARY TO PREVENT SEDIMENT FROM LEAVING THE WORK AREA. 5. CATCH ALL INLET FILTERS ARE REQUIRED AT ALL SEWER INLETS, GRATES AND MANHOLES FOR SEDIMENT CONTROL. 6. WETLAND AREAS SHALL HAVE SILT FENCING AND ONE LAYER OF STRAW LOG INSTALLED NO CLOSER THAN 50 FEET FROM POINT OF WETLAND DELINEATION. 7. TOPSOIL STOCKPILES SHALL BE LOCATED TO AVOID EROSION OF SAID STOCKPILE ONTO OFFSITE AREAS. 8. ALL ENVIRONMENTAL MEASURES SHALL BE PER PERTINENT DUKE NGBU DESIGN AND CONSTRUCTION STANDARDS. *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK I APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS ARR DATE N/A DATE N/A DATE 10/16/2020 INITIALS N/A INITIALS N/A INITIALS CAM APPROVALS REGIONAL ENGINEER (' DUKE Cc ENERGY MGR TECH REC & STD PRINCIPAL ENGINEER 011 Piedmont Natural Gas COPYRIGHT 2018 BELLAMY LAKE ROAD DOT RELOCATION COVER SHEET & DRAWING INDEX ENFIELD, NORTH CAROLINA TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA �BURNS PRELIMINARY - NOT MMONNELL FOR CONSTRUCTION CONSULTANTS, INC. ISSUED FOR 90% REVIEW SHEET(S) 1 OF 2 1 DWG SCALE NOT TO SCALE DWG DATE 10/16/2020 1 SUPERSEDED DRAWING NUMBER REVISIO PNG-G-027-0001051 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER LEGEND: x x x SS W E rc rc rc CATV SSFM UNK OH 9+00 8+00 E0A BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A MCMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP ROAD ASPHALT ROAD CONCRETE ROAD CURB ROAD DIRT ROAD GRAVEL ROAD CENTERLINE DRIVEWAY ASPHALT DRIVEWAY GRAVEL DRIVEWAY CONCRETE PAVEMENT ASPHALT DITCH/STREAM CENTERLINE SIDEWALK WALL RETAINING WALL BUILDING OUTLINE BUILDING OVERHEAD PROPERTY LINE SURVEYED PROPERTY RIGHT OF WAY LINE EASEMENT PNG LINE EASEMENT ACCESS LINE EASEMENT SANITARY SEWER LINE EASEMENT UTILITY LINE FENCE GUARDRAIL TREELINE SANITARY SEWER LINE GAS LINE WATER LINE POWER LINE FIBER OPTIC LINE TRAFFIC CONTROL LINE CABLE TV LINE TELEPHONE LINE SANITARY FORCE MAIN LINE UNKNOWN UTILITY LINE OVERHEAD WIRE STORM LINE TEMPORARY SILT FENCE PROPOSED CHAIN LINK SECURITY FENCE DEMOLISH & REMOVE LINEAR SITE FEATURE PROPOSED GRAVEL SURFACE COURSE WETLANDS CONTRACTOR HAUL ROUTE ■NI PROPOSED PIPELINE PROPOSED PERMANENT EASEMENT PROPOSED TEMPORARY WORKSPACE GENERAL NOTES: 1. THE EXISTING SITE UTILITIES AND FEATURES SHOWN ARE BASED ON A FIELD RUN TOPOGRAPHIC SURVEY PERFORMED BY MASER CONSULTING IN SEPTEMBER, 2020. 2. ALL DIMENSIONS, ELEVATIONS, AND STATIONS ARE IN FEET, UNLESS INDICATED OTHERWISE. 3. CALLOUTS, COORDINATES, AND DIMENSIONS ARE POINTED TO OR MEASURED TO STRUCTURE CENTER, EDGE OF PAVEMENT, BACK OF CURB, OR OUTSIDE FACE OF FOUNDATION WALL, UNLESS INDICATED OTHERWISE. 4. ALL WORK SHALL BE SUBJECT TO INSPECTION BY AUTHORIZED PERSONNEL OF LOCAL AND GOVERNMENT REGULATORY AGENCIES AND THE CLIENT REPRESENTATIVE. 5. SEE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) DESIGN STANDARDS FOR REFERENCES TO NCDOT STANDARD DRAWINGS. ALL SUBSEQUENT SPECIFICATIONS AND STANDARDS SHALL APPLY. 6. ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND LOCAL AND GOVERNMENT CODES, ORDINANCES, AND REGULATIONS. IN CASE OF CONTRADICTION OR DISCREPANCY BETWEEN REQUIREMENTS, CONTRACTOR SHALL INCORPORATE WHICHEVER IS MOST STRINGENT. WHERE A QUESTION REMAINS ON WHICH REQUIREMENT IS MOST STRINGENT, CONTRACTOR SHALL SUBMIT ISSUE TO THE CLIENT REPRESENTATIVE IN WRITING. THE DECISION OF THE CLIENT REPRESENTATIVE SHALL BE CONSIDERED FINAL. 7. ALL WORK SHALL BE CONDUCTED IN A PROFESSIONAL WORKMANSHIP MANNER USING USING QUALITY MATERIALS. WORK SHALL CONFORM TO THESE DRAWINGS, UNLESS INDICATED OTHERWISE OR AS DIRECTED BY THE CLIENT REPRESENTATIVE. 8. CONTRACTOR SHALL CONFINE ALL WORK TO BE WITHIN THE PERMANENT AND TEMPORARY EASEMENTS. 9. ALL GRADING, PAVEMENT WORK, AND ANY OTHER MISCELLANEOUS WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT NCDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION AND SUPPLEMENTAL SPECIFICATIONS. 10. CONTRACTOR SHALL TAKE CARE TO MAINTAIN THE SITE AND ADJACENT AREAS IN AS CLEAN A CONDITION AS POSSIBLE. ANY DEBRIS, DIRT, MUD, ETC. SHALL BE CLEANED DAILY, OR AS THE CLIENT REPRESENTATIVE DIRECTS, FROM ANY ADJOINING STREETS OR PROPERTIES BY THE CONTRACTOR AS A PART OF THE PRIMARY CONSTRUCTION WORK. THIS SHALL BE AT NO ADDITIONAL COMPENSATION TO THE CONTRACTOR. CONSTRUCTION DRAWING NOTES: 1. CONTRACTOR SHALL MAINTAIN UPDATED CONSTRUCTION DRAWINGS AT ALL TIMES THROUGH THE DURATION OF THE PROJECT. CONSTRUCTION RECORD DRAWINGS SHALL BE SUBMITTED TO THE CLIENT REPRESENTATIVE. 2. DURING CONSTRUCTION OF THE PROJECT, CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING TRACK OF ANY CLIENT REPRESENTATIVE -APPROVED FIELD CONSTRUCTION REVISIONS TO THE DESIGN DEPICTED ON APPROVED CONSTRUCTION DRAWINGS. 3. ALL VARIATIONS IN PROJECT CONDITIONS, LOCATIONS, AND CONFIGURATIONS, AND ANY OTHER CHANGES OR DEVIATIONS FROM THE INFORMATION PRESENTED ON THE ORIGINAL, APPROVED CONSTRUCTION DRAWINGS SHALL BE NOTED. THIS INCLUDES BURIED OR CONCEALED CONSTRUCTION AND UTILITY FEATURES THAT WERE REVEALED DURING CONSTRUCTION. 4. THE CLIENT REPRESENTATIVE SHALL REVIEW COMPLETENESS, ACCURACY, AND FORMAT OF SUBMITTED CONSTRUCTION DRAWINGS. IF THE CONSTRUCTION DRAWINGS ARE CONSIDERED UNACCEPTABLE, THEY SHALL BE RETURNED TO THE CONTRACTOR FOR CORRECTION AND RESUBMISSION. THIS SHALL BE AT NO ADDITIONAL COMPENSATION TO THE CONTRACTOR. COORDINATION AND COMMUNICATION 1. CONTRACTOR SHALL APPOINT A PRIMARY CONSTRUCTION SUPERINTENDENT, SUBJECT TO THE APPROVAL OF THE CLIENT REPRESENTATIVE, WHO SHALL BE PRESENT ON THE CONSTRUCTION SITE AT ALL TIMES DURING WORKING HOURS AND ACCESSIBLE AT ALL TIMES WHILE WORK IS IN PROGRESS. THE PRIMARY CONSTRUCTION SUPERINTENDENT SHALL BE DESIGNATED THE RESPONSIBLE CONTRACTOR'S REPRESENTATIVE WHO SHALL BE AVAILABLE ON A 24-HOUR BASIS. WHEN THE CONTRACTOR'S PRIMARY CONSTRUCTION REPRESENTATIVE IS NOT AVAILABLE ON THE CONSTRUCTION SITE, AN ALTERNATE REPRESENTATIVE SHALL BE PROVIDED. CONTRACTOR SHALL PROVIDE NAMES AND CONTACT INFORMATION OF REPRESENTATIVES TO THE CLIENT REPRESENTATIVE PRIOR TO THE START OF CONSTRUCTION ACTIVITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING CONSTANT COORDINATION BETWEEN ANY SUBCONTRACTORS AND THE CLIENT REPRESENTATIVE. ALL CONSTRUCTION ACTIVITIES PLANNED BY THE CONTRACTOR SHALL BE REVIEWED AND APPROVED BY THE CLIENT REPRESENTATIVE. 3. THE FOLLOWING CONTACT INFORMATION IS PROVIDED FOR CONTRACTOR'S USE IN CASE OF AN EMERGENCY: & EMERGENCY 911 b. (CONSTRUCTION) XXX-XXX-XXXX c. OTHER CONTACTS AS DIRECTED AT PRE -CONSTRUCTION MEETING EXCAVATION AND TRENCHES 1. CONTRACTOR SHALL COMPLY WITH THE MOST CURRENT EDITION OF OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REGULATIONS AND THE STATE OF NORTH CAROLINA LAWS CONCERNING EXCAVATION. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL EXCAVATION, TRENCHING AND SHORING ARE PERFORMED IN A MANNER THAT COMPLIES WITH LOCAL REGULATIONS AND OSHA REGULATIONS FOR CONSTRUCTION. 3. OPEN TRENCHES AND EXCAVATIONS AT THE CONSTRUCTION SITE SHALL BE PROMINENTLY MARKED WITH ORANGE BARRICADES WITH FLASHING RED LIGHTS ACCEPTABLE TO THE CLIENT REPRESENTATIVE. 4. CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 48 HOURS TO THE CLIENT REPRESENTATIVE AND ASSOCIATED UTILITY COMPANIES AND AGENCIES BEFORE PROCEEDING WITH ANY EXCAVATION. 5. DEWATERING OF UTILITY TRENCHES AND OTHER EXCAVATIONS MAY BE REQUIRED. 6. OPEN ONLY THOSE TRENCHES FOR WHICH MATERIAL IS ON -HAND AND READY FOR PLACING THEREIN. AS SOON AS POSSIBLE AFTER THE MATERIAL HAS BEEN PLACED AND WORK APPROVED, BACKFILL AND COMPACT TRENCHES AS SPECIFIED. 7. NO SPECIAL PROVISIONS WILL BE MADE FOR ROCK EXCAVATION, ANY BOULDERS ENCOUNTERED SHALL BE REMOVED AND DISPOSED OF OFF SITE. 8. ALL TOPSOIL SHALL BE REMOVED FROM AREAS TO BE GRADED. ALL USEABLE TOPSOIL SHALL BE STOCKPILED DURING GRADING AND REAPPLIED IN 3" LAYERS TO ALL SLOPES IMMEDIATELY AFTER GRADING IS COMPLETE. OTHER SAFETY REQUIREMENTS 1. CONTRACTOR SHALL MAINTAIN SAFETY PRACTICES THAT CONFORM TO OSHA REGULATIONS. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN AND PAY FOR ALL APPLICABLE PERMITS, FEES AND LICENSES FOR CONSTRUCTION AND EQUIPMENT. 3. THE CONTRACTOR SHALL PERFORM ON -SITE INSPECTIONS THROUGHOUT THE PROJECT AND REMEDY ANY SAFETY CONCERNS IMMEDIATELY. 4. THERE SHALL BE NO PERMANENT WASTE SITES ON SITE PROPERTY. ANY TEMPORARY WASTE AREA SHALL BE APPROVED BY THE CLIENT REPRESENTATIVE AND SHALL BE KEPT IN AN ORDERLY CONDITION. REMOVAL OF WASTE THAT IS NOT PROPERLY MAINTAINED IS SUBJECT TO THE DIRECTION OF THE CLIENT REPRESENTATIVE. 5. EROSION CONTROL DEVICES SHALL BE USED FOR THE ACCESS AND HAUL ROUTES, STAGING AREA, AND ANY MATERIAL STOCKPILES WHEN NECESSARY TO CONTROL EROSION AND STORM WATER RUNOFF. SEE DRAWINGS PNG-C-027-XXXXXXX THROUGH PNG-C-027-XXXXXXX FOR EROSION AND SEDIMENT CONTROL REQUIREMENTS. 6. STOCKPILED MATERIAL SHALL BE CONSTRAINED IN A MANNER TO PREVENT MOVEMENT RESULTING FROM WIND CONDITIONS. 7. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO LIMIT DUST CAUSED BY CONSTRUCTION ACTIVITIES TO A LIMIT ACCEPTABLE TO PROJECT SITE OPERATIONS. THE CONTRACTOR SHALL CONTROL BLOWING DUST ON THE PROJECT SITE FROM ANY HAUL ROUTE OR WORK AREA REGARDLESS OF SOURCE. 8. WILDLIFE ATTRACTANTS, SUCH AS TRASH AND FOOD SCRAPS, FROM CONSTRUCTION PERSONNEL AND ACTIVITIES SHALL BE REMOVED FROM THE PROJECT LIMITS. 9. GASOLINE, DIESEL FUEL, OIL, AND HAZARDOUS WASTE RESULTING FROM CONTRACTOR'S OPERATIONS OR ACTIVITIES SHALL BE PROPERLY DISPOSED OF IN ACCORDANCE WITH THE SPECIFICATIONS AND LOCAL REGULATORY REQUIREMENTS AND PROPERLY REMOVED FROM THE PROJECT PROPERTY. IF HAZARDOUS MATERIALS ARE ENCOUNTERED OR UNCOVERED DURING CONSTRUCTION ACTIVITIES, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CLIENT REPRESENTATIVE. 10. FAILURE TO COMPLY WITH THE CLIENT REPRESENTATIVE SAFETY REQUIREMENTS SHALL RESULT IN THE SUSPENSION OF CONSTRUCTION ACTIVITIES UNTIL ALL SAFETY CONCERNS ARE ADDRESSED BY THE CONTRACTOR TO THE SATISFACTION OF THE CLIENT REPRESENTATIVE. 11. ANY WORKERS AND EQUIPMENT NOT IN COMPLIANCE WITH SAFETY PLAN SHALL IMMEDIATELY BE REMOVED FROM THE WORK AREA. 12. THE CONTRACTOR SHALL NOT BURN OR BURY DEBRIS WITHOUT PERMISSION FROM THE SITE INSPECTOR. SURVEY AND SUBSURFACE INVESTIGATION NOTES: 1. SURVEY CONTROL POINTS WILL BE PROVIDED PRIOR TO CONSTRUCTION. IF THE CONTRACTOR SHOULD NEED TO DISTURB THE CONTROL POINTS DURING CONSTRUCTION, REQUEST SHALL BE GIVEN TO THE SURVEYOR TO HAVE THE CONTROL POINTS RESET. 2. IF BENCHMARKS SHOWN ARE IN AREAS THAT REQUIRE DEMOLITION, OTHER BENCHMARKS SHALL BE ESTABLISHED BEFORE DEMOLITION AND CONSTRUCTION WORK BEGINS. CONTRACTOR SHALL GIVE REQUEST TO THE SURVEYOR. 3. HORIZONTAL CONTROL IS BASED ON NAD 83 NORTH CAROLINA STATE PLANE, US FOOT. 4. VERTICAL CONTROL IS BASED ON NAVD 88. EXISTING CONDITIONS NOTES: 1. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS INDICATED HAVE BEEN OBTAINED FROM EXISTING RECORDS AND FIELD SURVEYS. UNDERGROUND STRUCTURES AND UTILITIES MAY BE PRESENT WHICH ARE NOT DOCUMENTED OR LOCATED. 2. THE CONTRACTOR SHALL FIELD -CHECK ALL EXISTING CONDITIONS AND BE THOROUGHLY FAMILIAR WITH THE SITE BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES IN THE DRAWINGS SHALL BE IMMEDIATELY REPORTED TO THE CLIENT REPRESENTATIVE BEFORE ANY FURTHER WORK COMMENCES, 3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD -VERIFY EXISTING STRUCTURES, UTILITIES, AND SURVEY INFORMATION, AND TO TAKE NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL VERIFY EXISTENCE AND MARK LOCATIONS OF ALL UTILITIES, INCLUDING SERVICE CONNECTIONS TO UNDERGROUND UTILITIES, PRIOR TO BEGINNING WORK. CONTRACTOR SHALL CONTACT THE CLIENT REPRESENTATIVE AND ALL ASSOCATED UTILITY COMPANIES AND AGENCIES TO IDENTIFY THE LOCATION OF UTILITIES. THERE IS NO GUARANTEE, EITHER EXPRESSED OR IMPLIED, THAT THE LOCATIONS, SIZE AND TYPE OF MATERIAL OF EXISTING UNDERGROUND UTILITIES INDICATED ARE REPRESENTATIVE OF THOSE TO BE ENCOUNTERED DURING CONSTRUCTION. 4. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE CLIENT REPRESENTATIVE OF OPERATIONAL PLANS. IN THE EVENT AN UNEXPECTED UTILITY OR STRUCTURE INTERFERENCE OR CONFLICT IS ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CLIENT REPRESENTATIVE. ANY UTILITY SERVICES OR STRUCTURES DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE RESTORED IMMEDIATELY AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 5. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ITEMS NOT TO BE DAMAGED DURING DEMOLITION AND CONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED OR DISTURBED ITEMS TO THE SATISFACTION OF THE CLIENT REPRESENTATIVE. GENERAL GRADING NOTES 1. ALL GRADING, PAVEMENT WORK, AND ANY OTHER MISCELLANEOUS WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT NC DOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION AND SUPPLEMENTAL SPECIFICATIONS. 2. THE GRAVEL SURFACE COURSE SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 520 OF THE NC DOT STANDARD SPECIFICATIONS, 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR GRADING INCLUDING EXCAVATION, EMBANKMENT, AND BACKFILLING AS NECESSARY TO CONSTRUCT ALL AGGREGATE ACCESS ROADS, AS OUTLINED IN THESE TECHNICAL SPECIAL PROVISIONS AND AS DIRECTED BY THE CLIENT REPRESENTATIVE. 4. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY DAMAGE DONE TO STORM MANHOLES OR OTHER UTILITIES DURING GRADING. 5. DISTRIBUTE EXCESS SOIL ON SITE AT THE DIRECTION OF THE CLIENT REPRESENTATIVE. DO NOT ALTER DIRECTION OF SURFACE DRAINAGE PATTERNS. 6. THE TOLERANCE OF THIS WORK SHALL BE TO WITHIN TO 0.1 FT OF THE EXISTING GROUND SURFACE ELEVATIONS. 7. THE ACCESS ROAD SUBGRADE SHALL HAVE SUFFICIENT STABILITY TO ACCOMMODATE CONSTRUCTION TRAFFIC WITHOUT EXCESSIVE SUBRADE RUTTING OR SHOVING. AT THE TIME OF PLACEMENT OF THE PAVEMENT, THE IN SITU SUBGRADE SHALL HAVE A CALIFORNIA BEARING RATIO (CBR) OF AT LEAST 6 PERCENT IN THE TOP 12 INCHES OF SUBGRADE. THE CBR PERCENTAGE WILL BE ASCERTAINED BY THE CONTRACTOR. 8. IF SOFT SPOTS ARE IDENTIFIED IN THE SUBGRADE SOIL, THE SUBGRADE SHALL BE SCARIFIED AND PROOF -ROLLED TO THE DEPTHS REQUIRED BY THE OWNER'S CONSTRUCTION INSPECTOR TO COMPACT AREAS TO THE DENSITY REQUIREMENTS OF THIS DOCUMENT. IF THE SOFT AREAS CANNOT BE ADEQUATELY COMPACTED, THE SOFT SOIL SHALL BE REMOVED AND REPLACED PER THE DESIGN PLANS WITH SUITABLE SOIL MATERIAL AND COMPACTED TO THE DENSITY REQUIREMENTS IN ACCORDANCE WITH THIS DOCUMENT. 9. THE QUALITY OF THE SOIL TO BE USED AS FILL MATERIAL SHALL BE AS SPECIFIED IN THIS DOCUMENT. ALL BACKFILL SHALL BE SPREAD IN LOOSE LIFTS NOT EXCEEDING 8" INCHES IN THICKNESS WHEN SELF-PROPELLED EQUIPMENT IS USED AND NOT EXCEEDING 6" WHEN HAND GUIDED EQUIPMENT IS USED. ALL ROOTS, WOOD, AND VEGETATION SHALL BE REMOVED FROM THE LAYER OF FILL PRIOR TO COMPACTION. ALL FILL AND EXPOSED SOIL IN CUT AREAS SHALL BE COMPACTED AS SPECIFIED IN THIS DOCUMENT. SOIL COMPACTION TESTS WILL BE REQUESTED BY THE OWNER AT APPROPRIATE INTERVALS DURING GRADING OPERATIONS. 10. ALL HAUL -IN MATERIAL SHALL BE FREE OF ROCKS 3" IN DIAMETER AND LARGER. THE OWNER'S CONSTRUCTION INSPECTOR SHALL APPROVE ALL HAUL -IN MATERIAL TO ENSURE THE QUALITY AND THE ABSENCE OF ENVIRONMENTAL HAZARDS. 11. THE FILL AREA SHALL BE CONSTRUCTED TO THE LINES AND GRADES SHOWN ON THE DESIGN DRAWINGS WITH MATERIAL SPECIFIED IN THIS DOCUMENT. THE CONTRACTOR SHALL LAY OUT ALL LINES AND GRADES FOR THE BACKFILL AREAS. ANY PROPOSED CHANGES TO THE SLOPES AND GRADES SHALL REQUIRE THE APPROVAL OF THE OWNER'S CONSTRUCTION INSPECTOR IN ADVANCE. THE CONTRACTOR SHALL BE REQUIRED TO REMOVE, AT HIS OWN EXPENSE, ANY COMPACTED MATERIAL PLACED OUTSIDE OF THE APPROVED LINES OR GRADES. 12. SPOIL MATERIAL SHALL BE TOPSOIL AND OTHER SOIL MATERIALS CONTAINING GREATER THAN 5 PERCENT ORGANIC MATERIAL, SOIL WHICH IS TOO WET, SOIL WHICH DOES NOT MEET THE PLASTICITY AND/OR GRADATION LIMITS FOR SELECT MATERIAL AS SPECIFIED IN THIS DOCUMENT, OR OTHER SOIL MATERIAL DESIGNATED BY THE OWNER'S CONSTRUCTION INSPECTOR TO BE UNSUITABLE FOR SELECT MATERIAL. 13. SELECT SOIL MATERIAL SHALL BE THAT MATERIAL CLASSIFIED AS SM, SP, SC, SW AND CL, OR SW AND SC IN ACCORDANCE WITH ASTM D2487, AND SHALL HAVE A MAXIMUM LIQUID LIMIT OF 30, A MAXIMUM PLASTICITY INDEX OF 8, AND A MAXIMUM OF 35 PERCENT PASSING THE #200 SIEVE. 14. THE TOP SURFACE OF EACH LIFT OF BACKFILL SHALL BE PROTECTED FROM PUMPING, PONDING, AND GULLYING. 15. COMPACTION TESTING WILL BE PROVIDED AT THE EXPENSE OF THE CONTRACTOR. COMPACTION REQUIREMENTS OF SOIL BACKFILL SHALL BE AS INDICATED IN THE FOLLOWING TABLE: LOCATION OF FILL MINIMUM REQUIRED COMPACTION LEVEL STANDARD PROCTOR A. GENERAL YARD AREA 98%(ASTM D698) B. UPPER 18 INCHES OF SOIL TO BE USED AS 98%(ASTM D698) ROAD SUBGRADE MATERIAL AND EXTENDING A MINIMUM OF 5 FEET BEYOND THE EDGE OF DEFINED ROADWAYS (IMMEDIATELY UNDER BASE MATERIAL) 15. CRUSHED STONE IN DRIVE AREAS SHALL BE COMPACTED WITH A STATIC STEEL DRUM ROLLER (APPROXIMATELY 8 TONS). IF A VIBRATORY COMPACTOR IS USED, NO MORE THAN FOUR (4) PASSES SHALL BE ALLOWED. 16. APPROVAL SHALL BE RECEIVED FROM THE CLIENT REPRESENTATIVE FOR EACH FILL TYPE TO BE USED PRIOR TO PROCEEDING WITH BACKFILL OPERATIONS WITH THE MATERIAL IN QUESTION. 17. BACKFILL TO BE IMPORTED SHALL BE TESTED IN ACCORDANCE WITH THIS DOCUMENT AND APPROVED BY THE PROJECT MANAGER PRIOR TO DELIVERY OF MATERIAL TO THE SITE. THE OWNER'S CONSTRUCTION INSPECTOR ACCEPTS NO LIABILITY FOR ANY OUT OF SPECIFICATION MATERIAL ACCEPTED AND STOCKPILED BY THE CONTRACTOR 18. INSPECTION AND TESTING OF MATERIAL SHALL BE PERFORMED AS REQUIRED BY THIS DOCUMENT AT THE EXPENSE OF THE CONTRACTOR. 19. TESTS AND ANALYSIS OF MATERIAL SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE STANDARDS REFERENCED IN THIS DOCUMENT FOR THE SPECIFIC TEST. FIELD INSPECTION SHALL BE PERFORMED AS REQUIRED BY THIS DOCUMENT. 20. THE BACKFILL AND EXPOSED SOIL IN CUT AREAS SHALL BE COMPACTED AS SPECIFIED ON THIS DOCUMENT. FIELD DENSITY TESTS SHALL BE PERFORMED BY THE CONTRACTOR TO VERIFY COMPACTION REQUIREMENTS HAVE BEEN ACHIEVED. IN -PLACE FIELD DENSITY TESTING OF THE COMPACTED BACKFILL SHALL BE CONDUCTED ACCORDING TO THE PROCEDURES OF THE SAND CONE METHOD (ASTM 1556), NUCLEAR METHOD (ASTM D3017), OR ACCORDING TO THE PROVISIONS OF THIS DOCUMENT. TEST RESULTS REPORTED SHALL INCLUDE BOTH THE MOISTURE CONTENT AND DRY DENSITY, ALONG WITH OTHER PERTINENT DATA SUCH AS LOCATION, ELEVATION, PROCTOR CURVE USED FOR COMPARISON, ETC. THE TESTING FREQUENCY SHALL BE ONE TEST FOR EACH 5,000 SQUARE FEET OF LIFT AREA OR PORTION THEREOF FOR EACH LIFT. IN ISOLATED AREAS OF LESS THAN 5,000 SQUARE FEET, TEST AT LEAST EVERY THIRD LIFT. WHEN BACKFILL OPERATIONS ARE CONCENTRATED IN SMALL AREAS USING LIGHT MANUALLY -GUIDED EQUIPMENT AND RELATIVELY THIN LIFTS, THE FREQUENCY OF DENSITY TESTING MAY BE REVISED AS DIRECTED BY THE OWNER'S CONSTRUCTION INSPECTOR. TEST LOCATION SHALL BE THE WEAKEST APPEARING AREA OF THE TOP LIFT DETERMINED BY TRACKING ACTION OF THE EQUIPMENT. 21. SUITABILITY OF SOIL MATERIAL FOR USE AS BACKFILL SHALL BE DETERMINED FOR EACH FILL TYPE BY THE RESULTS OF THE FOLLOWING TESTS: A. LIQUID LIMIT IN ACCORDANCE WITH ASTM D4318. B. PARTICLE SIZE ANALYSIS IN ACCORDANCE WITH ASTM D422. C. MOISTURE -DENSITY RELATIONS (STANDARD PROCTOR) IN ACCORDANCE WITH ASTM D698. D. MOISTURE CONTENT IN ACCORDANCE WITH ASTM D2216. E. SAMPLING OF SOIL SHALL BE IN ACCORDANCE WITH ASTM D2216. F. SOIL SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM D2487. 22. FREQUENCY OF TESTS: TESTS OF MATERIALS TO BE USED IN THE OPERATIONS COVERED IN THIS DOCUMENT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS GIVEN IN THIS DOCUMENT. FREQUENCIES OF IN -PLACE DENSITY TESTS SHALL BE AS STATED IN THIS DOCUMENT. 23. IF QUESTIONABLE COMPACTION RESULTS ARE OBTAINED, THE CLIENT REPRESENTATIVE MAY REQUIRE THE CONTRACTOR TO PERFORM PROCTOR CHECKS (ON DRY SIDE OF OPTIMUM) TO VERIFY THAT THE PROPER PROCTOR CURVE IS BEING REFERENCED. IF NOT, A NEW PROCTOR CURVE DETERMINED BY A FIVE -POINT TEST SHALL BE REQUIRED. IF THE COMPACTION REQUIREMENTS FOR A LIFT HAVE NOT BEEN ACHIEVED, THE LIFT SHALL BE REWORKED OR REPLACED AT THE CONTRACTOR'S EXPENSE. 24. TESTING OF IN -PLACE DENSITY AND MOISTURE CONTENT BY NUCLEAR METHODS IN ACCORDANCE WITH ASTM D2922 AND ASTM D3017, RESPECTIVELY, WILL BE ALLOWED PROVIDED: A. ACCEPTABLE CORRELATION WITH SAND CONE DENSITY AND LABORATORY DETERMINED MOISTURE CONTENT TEST RESULTS CAN BE OBTAINED ACCORDING TO THE GUIDELINES OF "CALIBRATION" SECTIONS OF ASTM D2922 AND ASTM D3017. B. THE INITIAL CORRELATION RESULTS ARE REVIEWED AND USE OF THE NUCLEAR DEVICE IS APPROVED BY THE OWNER'S CONSTRUCTION INSPECTOR. C. THE CONTRACTOR INSURES THAT THE REPRESENTATIVE FROM THE TESTING AGENCY OPERATING THE NUCLEAR DENSITY TESTING HAS THE NECESSARY STATE AND/OR FEDERAL LICENSES TO OPERATE THE DEVICE AND CARRY A NUCLEAR ENERGY SOURCE. EMBANKMENT FILL NOTES: 1. EMBANKMENT FILL SHALL CONSIT OF AN INORGANIC, NON -PLASTIC, GRANULAR SOIL CONTAINING LESS THAN 10% MATERIAL PASSING THE NO.200 MESH SIEVE WITH UNIFIED SOIL CLASSIFICATION OF SP, SP-SC, OR SP-SM. EMBANKMENT FILL SHALL BE PLACED IN LIFTS NOT EXCEEDING 8 INCHES WHEN USING A STATIC DRUM ROLLER WITH A MINIMUM OPERATING WEIGHT OF 5 TONS WITH A DRUM DIAMETER OF 3 TO 4 FEET. WHERE LIGHTWEIGHT VIBRATORY COMPACTION METHODS ARE UTIILIZED MAXIMUM LOOSE LIFT THICKNESS SHALL BE 6 INCHES. COMPACTION TO MEET A MAXIMUM DRY DENSITY OF 98% STANDARD PROCTOR DRY DENSITY. 2. ANY GRADING TO CORRECT SLOPES SHALL BE COMPACTED PER THIS DOCUMENT. GENERAL EXCAVATION REQUIRED FOR CONSTRUCTION 1. THIS ITEM SHALL CONSIST OF FURNISHING ALL LABOR, MATERIALS, MACHINERY, TOOLS, AND SUPERVISION FOR EXCAVATION AND GRADING REQUIRED TO PREPARE THE ROADWAY, AND GRADING REQUIRED TO COMPLETE THE FINAL GRADING OF AREAS ADJACENT TO THE ROADWAY AS SHOWN ON THE PLANS IN ACCORDANCE WITH THE PROVISIONS OF SECTION 225 OF THE NC DOT STANDARD SPECIFICATIONS INSOFAR AS THEY ARE NOT AMENDED BY THE PLANS AND THESE SPECIAL PROVISIONS, AND IN ACCORDANCE WITH THE FOLLOWING SPECIAL PROVISIONS. SUBGRADE COMPACTION VERIFICATION 1. THE CONTRACTOR SHALL EMPLOY AN INDEPENDENT CONSTRUCTION MATERIAL ENGINEERING TESTING FIRM TO MONITOR THE PROOFROLLING OF THE SITE AFTER THE STRIPPINGS HAVE BEEN REMOVED TO INSPECT AND TEST THE COMPACTED FILL AREAS IN THE ACCESS ROAD AREAS AS INDICATED ON THE BID DOCUMENTS AND/OR AS SPECIFIED BY THE OWNER'S DESIGNATED REPRESENTATIVE. COPIES OF THE TEST RESULTS SHALL BE FURNISHED TO THE OWNER'S DESIGNATED REPRESENTATIVE AND OTHERS AS INDICATED BY OWNER'S DESIGNATED REPRESENTATIVE. THE OWNER'S DESIGNATED REPRESENTATIVE MUST APPROVE THE INDEPENDENT CONSTRUCTION MATERIAL ENGINEERING TESTING FIRM. INCLUDED WITH THIS BID PROPOSAL, THE CONTRACTOR SHALL FURNISH THE NAME, ADDRESS AND A PHONE NUMBER OF THE INDEPENDENT CONSTRUCTION MATERIAL ENGINEERING TESTING FIRM FOR APPROVAL. ABBREVIATIONS: ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS BOC BACK OF CURB CB CATCH BASIN CBR CALIFORNIA BEARING RATIO C/L CENTERLINE COMB COMBINATION BEND (VERT. & HOR. DIRECTIONAL CHANGE) CONC CONCRETE CI CURB INLET CMP CORRUGATED METAIL PIPE DB DEED BOOK DI DROP INLET DR DRIVE ELEC ELECTRICAL EOP EDGE OF PAYMENT EX EXISTING FT FEET FTG FITTING JAB JACK AND BORE GIS GEOGRAPHIC INFORMATION SYSTEM LL LAND LOT MAX MAXIMUM MIN MINIMUM MISC MISCELLANEOUS NTS NOT TO SCALE PG PAGE PVC POLYVINYL PLASTIC PIPE NCDEQ NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY NCDOT NORTH CAROLINA DEPARTMENT OF TRANSPORTATION N/F NOW OR FORMERLY NPDES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NTS NOT TO SCALE OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PC POINT OF CURVATURE P/L PROPERTY LINE PT POINT OF TANGENCY RCP REINFORCED CONCRETE PIPE R/W RIGHT OF WAY SAG SAG (PIPE DIRECTION UP) SBL SIDE BEND LEFT SBR SIDE BEND RIGHT SSMH SANITARY SEWER MANHOLE STMH STORM MANHOLE *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK I APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 DATE ACCOUNT NUMBER 10700 N/A PROJECT NUMBER MX5694600 DATE DRAWING BY MJD N/A STATION ID I DATE CHECKER INITIALS ARR 10/16/2020 APPROVALS INITIALS REGIONAL BELLAMY LAKE ROAD DOT RELOCATION NIA ENGINEER INITIALS MGR TECH %DUKE Piedmont CIVIL GENERAL NOTES LEGENDS & ABBREVIATIONS NIA � ENERGY 0111 Natural Gas , REC&STD ENFIELD, NORTH CAROLINA INITIALS PRINCIPAL CAM ENGINEER COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW SHEET(S) 2 OF 20 DWG SCALE NOT TO SCALE DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISIO PNG-G-027-0001052 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A. McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP Maximo Part # BOM Legacy Data Source Qty Retired? Description # Number Sheet? System 1 13520 1550838 PNG 3600 FT PIPE, 8" I PS, 40' LG, PLAIN ENDS, EXTRUDED, SDR 11.5, 76 LB, PE 2708 (PE 2406), ASTM D2513 2 13536 1551318 PNG 4 ELBOW, PI PE, 8" 1 PS, BUTT FUSION, 90 DEG, PE 2708 (PE 2406), ASTM D3261, SDR 11 3 13540 1552623 PNG 4 ELBOW, PI PE, 8" 1 PS, BUTT FUSION, 45 DEG, PE 2708 (PE 2406), ASTM D3261, SDR 11 4 13538 50092525 PNG 2 COUPLI NG, PI PE, 8" 1 PS, ELECTROFUSI ON, PE 4710, ASTM F1055, 64 LB @ 73.4 DEG, PRODUCT CODE AE06-20 STD P KG/4 5 13676 1553683 PNG 2 CAP, P I P E, 8" 1 PS, B UTT F US I ON, P E 2708 (P E 2406) , ASTM D2513/ASTM F 1055, S D R 11, C E NTRAL PLASTICSPART# 691082200000 *******DRISCOPIPE 6500 PART# 65MO80110CPSTY******* PLEXCO YELLOWPIPE369209 PLEXCO *******UPONOR UAC 2000 PART# 5158630000810 *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK I APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS I ARR APPROVALS DATE INITIALS N/A NIA REGIONAL ENGINEER DATE INITIALS MGR TECH N/A NIA REC & STD DATE INITIALS PRINCIPAL 10/16/2020 CAM ENGINEER BELLAMY LAKE ROAD DOT RELOCATION DUENERr6livaturaliedt BILL OF MATERIALS ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW SHEET(S) 3 OF 2 1 DWG SCALE NOT TO SCALE DWG DATE 10/16/2020 1 SUPERSEDED DRAWING NUMBER REVISIO PNG-G-027-0001153 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER BEGIN STA. 10+00 CONTRACTOR A i' i' r—r%r% P t'1I ITr— / ;BELLAMY LAKE ROAR/W —R/W -- R' D / 0 K/VV 4� FISHING CREEK zz it PERENNIAL STREAM S-PKM-01 RB W-PKM-03 i-� ��•\\�� ` \. \. I / it �I I 111 IIII WETLANDS I'll !I I !������3 //j I I `� S IIII �1111 111111/ / I uii : vx £�.�'" �{� 1q'����� f 1 c." GRAVEL CONSTRUCTION ENTRANCE PIN: 3867-00-77-2124 BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 n PROFESSIONAL ENG/ARCH STAMP WETLANDS PIN: 3867-00-86-4556 w' PERENNIAL STREAM S-PKM-02 PIN: 3877-00-03-4622 PERENNIAL STREAM S-PKM-02 PIN: 3877-00-08-7245 PROPOSED PERMANENT ACCESS ROAD SEE DETAIL 2, SHEET PNG-027-0001132 PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY �111`ti CONTRACTOR ACCESS ROUTE ACCESS AND STAGING 1. ACCESS AND HAUL ROUTES FOR ALL CONTRACTOR PERSONNEL, VEHICLES, EQUIPMENT, AND DELIVERIES ARE ILLUSTRATED ON THIS DRAWING AND ARE SUBJECT TO THE APPROVAL OF THE CLIENT REPRESENTATIVE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE OFF -SITE HAUL ROUTES WITH THE APPROPRIATE OWNER WHO HAS JURISDICTION OVER THE AFFECTED ROUTE. ACCESS ROUTES AND HAUL ROUTES ARE SUBJECT TO CHANGE AT THE DIRECTION OF THE CLIENT REPRESENTATIVE AND MAY CHANGE BASED ON OPERATIONAL REQUIREMENTS OF THE SITE. 2. CONTRACTOR SHALL COORDINATE ACTIVITIES AND MAINTAIN ALL ACCESS AND HAUL ROUTES IN A MANNER THAT ALLOWS UNOBSTRUCTED EMERGENCY ACCESS TO ALL PROJECT AREAS AND EXISTING ROADWAYS AT ALL TIMES WITHOUT DELAY TO EMERGENCY AND SECURITY VEHICLE RESPONSE TIME. 3. IF ANY EMERGENCY ROUTES REQUIRE CLOSURE DUE TO CONSTRUCTION ACTIVITIES, CONTRACTOR SHALL NOTIFY THE CLIENT REPRESENTATIVE, POLICE, LOCAL FIRE AUTHORITY, AND ALL OTHER EMERGENCY SERVICES OF THE CLOSURE. 4. CONTRACTOR SHALL MAINTAIN ACCESS AND HAUL ROUTES TO BE FREE FROM DEBRIS CAUSED FROM CONSTRUCTION ACTIVITIES ON A DAILY BASIS. 5. CONTRACTOR SHALL RESTRICT ALL OPERATIONS TO AREAS WITHIN THE CONSTRUCTION LIMITS UNLESS COORDINATED OTHERWISE WITH THE CLIENT REPRESENTATIVE. 6. WHEN NOT ENGAGED IN CONSTRUCTION ACTIVITIES, CONTRACTOR'S EQUIPMENT AND VEHICLES SHALL BE PARKED IN THE STAGING AREA. 7. ACCESS POINTS, HAUL ROUTES, STAGING AREA, AND ANY OTHER AREAS DISTURBED BY THE CONTRACTOR SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER TO THE SATISFACTION OF THE CLIENT REPRESENTATIVE. TRAFFIC CONTROL 1. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CORDON OFF THE CONSTRUCTION WORK AREA AND ASSOCIATED ROADWAYS BY USING BARRICADES APPROVED BY THE CLIENT REPRESENTATIVE. 2. ALL CONSTRUCTION EQUIPMENT AND VEHICLES SHALL BE MARKED WITH COMPANY DESIGNS, INSIGNIAS, OR OTHER MARKINGS, WHICH ARE CLEARLY VISIBLE. 3. CONSTRUCTION EQUIPMENT SHALL HAVE AUTOMATIC SIGNALING DEVICES TO SOUND AN ALARM WHEN MOVING IN REVERSE. 4. NO PEDESTRIAN TRAFFIC SHALL BE ALLOWED INSIDE THE CONSTRUCTION LIMITS. 5. ANY DAMAGE TO ROADS AND PAVEMENTS -TO -REMAIN DUE TO CONSTRUCTION EQUIPMENT OR TRAFFIC SHALL BE REPAIRED TO RESTORE THE ROADS AND PAVEMENTS TO THEIR ORIGINAL CONDITION TO THE SATISFACTION OF THE CLIENT REPRESENTATIVE. PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO. DATE REVISION(S) DESCRIPTION BY CHK APPD I DESCRIPTION APPROVALS �jDUKE Piedmont ENERGY: 0111 Natural Gas COPYRIGHT 2018 BELLAMY LAKE ROAD DOT RELOCATION ACCESS ROUTE PLAN ENFIELD NORTH CAROLINA TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA A 10-16-2020 ISSUED FOR 90% REVIEW LLO JTG CAM AREA CODE 1910 DATE N/A INITIALS N/A REGIONAL ENGINEER ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DATE N/A INITIALS N/A MGR TECH REC&STD DRAWING BY LLO STATION ID DATE 10/16/2020 INITIALS CAM PRINCIPAL ENGINEER CHECKER INITIALS JTG 0 200' 400' SCALE IN FEET LIMITS OF DISTURBED AREA PIPELINE PROJECT: 3.20 AC POINT OF CONTACT (MAINTENANCE): BRANDON TAYLOR (XXX)-XXX-XXXX PRELIMINARY - NOT FOR CONSTRUCTION 90% DESIGN SUBMITTAL SHEET(S) 4 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION PNG-C-027-0001119 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER PIN: 3867-00-77-2124 PIN: 3867-00-86-4556 } � OWNERSHIP BELLAMY LAKE ROAD R/W 60' TIM W. FISHER AND KAY W. FISHER ROCKY ROAD FARMS LLC } � ILL D B 1684 /PAGE 586 D B 2952 /PAGE 187 0 � ACREAGE 0 U Z a O U z U s 0 U 0 0 z U N Cco U-1 LU M CD cn OIL D IV) I j - man man ILI wimewwwwam I PIN: Jill,EMa LU man Ij man no wan Mang Ji CL CD 0 LU LU 4� Of �15+00 16+00 IIIV�� 17+0018+00 19+00 20+00 21 +00 ► 22+00 ► 23+00 0_i' CL OD 0 PIN: 3867-00-86-4556 PIN: 3877-00-03-4622 PIN: 3877-00-08-7245 � OWNERSHIP ROCKY ROAD FARMS LLC WILIS CONRAD ELSIE MOZINGO REVOCABLE LIVING TRUST FREDERICK M. DUNN & ELAINE T. DUNN � ILL D B 2952 /PAGE 187 D B 2035 /PAGE 363 D B 1445 /PAGE 456 0 � ACREAGE a c 0 U Z a O U z U s 0 U 0 0 z U N CLu D 04 — Lu CL "k milk L ENERGY. Natural PIN: 3877-00-08-7245 } BELLAMY LAKE ROAD } � OWNERSHIP FREDERICK M. DUNN & ELAINE T. DUNN R/W 60' � ILL D B 1445 /PAGE 456 0 � ACREAGE c� o' EASEMENTS REF. DWG. N0. a c 0 U z a O U z U s 0 U 0 0 z U N CCD CD CN AL D LU LU — cn La 0 CUT GENERAL NOTES: PROPOSED PIPELINE SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH PIEDMONT NATURAL GAS' DESIGN AND CONSTRUCTION MANUALS, LATEST EDITION. ALL EQUIPMENT MUST ACCESS THE SITE ALONG THE CONSTRUCTION RIGHT-OF-WAY OR FROM APPROVED ACCESS ROADS. CONTRACTOR SHALL SUBMIT ANY REQUESTS FOR DEVIATION FROM THIS DESIGN FOR REVIEW PRIOR TO CONSTRUCTION. CONTRACTOR SHALL DISPOSE OF EXCESS DRILLING FLUID AS DIRECTED BY THE COMPANY REPRESENTATIVE IN ACCORDANCE WITH PERMIT CONDITIONS, UNDER NO CIRCUMSTANCES SHALL DRILLING FLUID BE DISPOSED OF IN WATER BODIES OR WETLANDS. THE ENTRY AND EXIT POINTS SHALL BE CONTAINED AND COLLECTED TO THE EXTENT PRACTICAL AND DISPOSED OF AS DIRECTED BY THE COMPANY REPRESENTATIVE IN ACCORDANCE WITH PERMIT CONDITIONS. EXISTING UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE AND ARE TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. 125 120 115 110 105 100 95 90 85 80 75 Lu J 70 U- 0 a 65 60 55 50 45 40 35 30 25 20 10+50 11+00 BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 rl CLAUDE A MdVIULLAN e IFC SUBMITTAL DATE °I NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP J CONTRACTOR SHALL VERIFY ALL COORDINATES AND DIMENSIONAL INFORMATION PRIOR TO CONSTRUCTION. BRING ANY DISCREPANCIES WITH LAYOUT TO ATTENTION OF COMPANY PRIOR TO STARTING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR KNOWING LOCATION OF ALL ENVIRONMENTALLY SENSITIVE AREA RESTRICTIONS PERTAINING TO THIS PROJECT. GEOTECHNICAL NOTES: GEOTECHNICAL DATA PROVIDED BY ATC GROUP SERVICES, LLC. REFER TO THE PROJECT GEOTECHNICAL BORING LOGS ON SHEET PNG-C-027-0001140 FOR MORE DETAILED SUBSURFACE INFORMATION. THE GEOTECHNICAL DATA IS ONLY DESCRIPTIVE OF THE LOCATIONS ACTUALLY SAMPLED. EXTENSION OF THE DATA OUTSIDE OF THE ORIGINAL BORINGS MAY BE DONE TO CHARACTERIZE THE SOIL CONDITIONS. HOWEVER, COMPANY DOES NOT GUARANTEE THESE CHARACTERISTICS TO BE ACCURATE. CONTRACTOR MUST USE HIS OWN EXPERIENCE AND JUDGEMENT IN INTERPRETING THIS DATA. HORIZONTAL LENGTH = 837' TRUE DRILLED LENGTH = 850' TOPOGRAPHIC SURVEY NOTES: TOPOGRAPHIC SURVEY DATA PROVIDED BY MASER CONSULTING P.A. NORTHINGS AND EASTINGS ARE IN U.S. SURVEY FEET REFERENCED TO NORTH CAROLINA STATE PLANE COORDINATES. ELEVATIONS ARE IN FEET REFERENCED TO NAVD 88. DRILL PATH NOTES: DRILL PATH STATIONING IS IN FEET BY HORIZONTAL MEASUREMENT AND IS REFERENCED TO CONTROL ESTABLISHED FOR THE DRILLED SEGMENT. DRILL PATH COORDINATES REFER TO THE CENTERLINE OF PILOT HOLE AS OPPOSED TO TOP OF INSTALLED PIPE. HORIZONTAL DIRECTIONAL DRILL PATH DEPICTS MINIMUM REQUIREMENTS ONLY. FINAL PATH TO BE DETERMINED BY CONTRACTOR AT TIME OF CONSTRUCTION. PILOT HOLE TOLERANCES: THE PILOT HOLE SHALL BE DRILLED TO THE TOLERANCES LISTED BELOW. HOWEVER IN ALL CASES, RIGHT-OF-WAY RESTRICTIONS AND CONCERN FOR ADJACENT FACILITIES SHALL TAKE PRECEDENCE OVER THESE TOLERANCES. 1. ENTRY POINT: NO MODIFICATIONS SHALL BE MADE WITHOUT APPROVAL FROM THE COMPANY ENGINEER. 2. ENTRY ANGLE: UP TO 1' INCREASE FROM THE DESIGNED ENTRY ANGLE; NO DECREASE IN ENTRY ANGLE WILL BE ALLOWED. 3. EXIT POINT: UP TO 20 FEET LONGER OR 10 FEET SHORTER FROM THE EXIT POINT; UP TO 5 FEET RIGHT OR LEFT OF THE DESIGNED ALIGNMENT. 4. EXIT ANGLE: NO INCREASE FROM THE DESIGNED EXIT ANGLE; UP TO 2° DECREASE IN EXIT ANGLE WILL BE ALLOWED. 5. ELEVATION: UP TO 2 FOOT ABOVE AND 10 FEET BELOW DESIGNED PROFILE. 6. ALIGNMENT: UP TO 5 FEET RIGHT OR LEFT OF THE DESIGNED ALIGNMENT. I PERENNWIAL�/HDD EXIT �� - HDD PULL STRINGING AREA, \� / STREAM / / / / /��'� 1- - - �� -,' �11� ' APPROX. 425', 2 STRINGS SPKM1 LB I I I W-PKM-02 PIN: 3867-00-86-4556 7. CURVE RADIUS: NO LESS THAN 400 FEET BASED ON A 3 JOINT AVERAGE. PROTECTION OF EXISTING FACILITIES: CONTRACTOR SHALL UNDERTAKE THE FOLLOWING STEPS PRIOR TO COMMENCING DRILLING OPERATIONS: 1. CONTACT THE UTILITY LOCATION IDENTIFICATION SERVICE FOR THE CONSTRUCTION AREA. 2. POSITIVELY LOCATE AND STAKE ALL EXISTING UNDERGROUND FACILITIES. ANY FACILITIES LOCATED WITHIN 10 FEET OF THE DESIGNED PATH SHALL BE EXPOSED. 3. MODIFY DRILLING PRACTICES AND DOWNHOLE ASSEMBLIES AS NECESSARY TO PREVENT DAMAGE TO EXISTING FACILITIES. / // /// / G / I %�__ / �18+00 19+00 20+00 21+00► 22+00- 23+00 now_ _ _ _ unwann wanywann 1.7 / / / / 25' TEMPORARY WORKSPACE SOIL BORING B-2 STA:22+44 NOTE: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL EXISTING UTILITIES AND OTHER STRUCTURES. CONTRACTOR SHALL BE RESPONSIBLE FOR LOSSES AND REPAIRS OCCASIONED BY DAMAGE TO FACILITIES RESULTING FROM DRILLING OPERATIONS. CONTRACTOR SHALL TAKE STEPS TO PROTECT EXISTING FACILITIES, INCLUDING, BUT NOT LIMITED TO, SETTING SURFACE CASING AS NECESSARY TO PREVENT SETTLEMENT AND DISPLACEMENT. NOTE: STRATIFICATION LINES AND SUBSURFACE MATERIAL DESCRIPTIONS SHOWN ON THIS DRAWING HAVE BEEN SIMPLIFIED FOR PRESENTATION PURPOSES. REFER TO THE PROJECT GEOTECHNICAL BORING LOGS AND REPORT FOR MORE DETAILED SUBSURFACE INFORMATION. NOTE: CONTRACTOR SHALL ACTIVELY MONITOR THE DRILLED ALIGNMENT FOR IMPACTS THAT COULD OCCUR AS A RESULT OF HDD OPERATIONS (I.E. SETTLEMENT, HEAVE, AND DRILLING FLUID FLOW). CONTRACTOR'S MONITORING PROCEDURES AND ASSOCIATED EMERGENCY RESPONSE PLANS SHALL B APPROPRIATE TO ENSURE THAT PUBLIC SAFETY IS NOT COMPROMISED. `ram "4+00MINE HDD EXIT AT 12' STA:19+21 ELEVA 16' - - - - 70.5- - -2.0 - - - - - - - - - - - - - - - - - - EEZE- -6.0 HDD ENTRY AT 12° STA:10+84 ELEV:101' EXISTING GRADE - PROPOSED 8" PE -8.0/� -13.0 / DISTRIBUTION MAIN - - - - - 90° FITTING (H) - - STA:11 +05 -0.5 ::: -23.0 ...: ELEV:97' -2.071A -4.0 - - - -28.0 I -13.0 SOIL BORING B-1 SOIL BORING B-2 SEE PNG-C-027-0001140 / -36.0 / / SEE PNG-C-027-0001140 DESIGNED DRILL PROFILE 8" HDPE DISTRIBUTION MAIN -18.0 -42.3 -21.5 -25.0 -48.5 PC / ENTRY CURVE STA:12+79 ELEV:60' PT / EXIT CURVE STA:16+54 ELEV:60' -30.0 / / -53.5 _ 35.0 R=400' PT / ENTRY CURVE N R=400' -58.5 -40.0 } STA:13+62 ELEV:51' -63.5 / -45.0 -68.5 -50.0 / 208' -75.0 / PC / EXIT CURVE -55.0 STA:15+71 ELEV:51' -60.0 / / -65.0 -70.0 -75.0 I 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO. DATE REVISION(S) DESCRIPTION BY CHK APPD DESCRIPTION APPROVALS A 10-16-2020 ISSUED FOR 90% REVIEW MJD ARR CAM AREA CODE 1910 DATE INITIALS REGIONAL BELLAMY LAKE ROAD DOT RELOCATION ACCOUNT NUMBER 10700 NIA N/A ENGINEER PROJECT NUMBER MX5694600 DATE INITIALS MGR TECH DUN E 0111 Na tural f•aPiedmont HDD DETAIL SHEET 1 - FISHING CREEK DRAWING BY MJD NIA N/A REC &STD STATION ID DATE INITIALS PRINCIPAL E N F I E LD NORTH CAROLINA CHECKER INITIALS ARR 10/16/2020 CAM ENGINEER COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA HDD - 8" PIPELINE PLAN 0 50 100 00119 HORIZONTAL 1IN = 50FT 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 HDD - 8" PIPELINE 40 35 30 25 20 24+50 REF. DWG(S) PROFILE 0 50 100 00119 HORIZONTAL 1IN = 50FT 0 10 20 VERTICAL 1IN = 1OFT PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW PNG-G-027-XXXXXX1 z Q J d w J U- 0 a SHEET(S) 8 OF 2 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION PNG-C-027-0001123 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER GENERAL NOTES: PROPOSED PIPELINE SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH PIEDMONT NATURAL GAS' DESIGN AND CONSTRUCTION MANUALS, LATEST EDITION. ALL EQUIPMENT MUST ACCESS THE SITE ALONG THE CONSTRUCTION RIGHT-OF-WAY OR FROM APPROVED ACCESS ROADS. CONTRACTOR SHALL SUBMIT ANY REQUESTS FOR DEVIATION FROM THIS DESIGN FOR REVIEW PRIOR TO CONSTRUCTION. CONTRACTOR SHALL DISPOSE OF EXCESS DRILLING FLUID AS DIRECTED BY THE COMPANY REPRESENTATIVE IN ACCORDANCE WITH PERMIT CONDITIONS, UNDER NO CIRCUMSTANCES SHALL DRILLING FLUID BE DISPOSED OF IN WATER BODIES OR WETLANDS. THE ENTRY AND EXIT POINTS SHALL BE CONTAINED AND COLLECTED TO THE EXTENT PRACTICAL AND DISPOSED OF AS DIRECTED BY THE COMPANY REPRESENTATIVE IN ACCORDANCE WITH PERMIT CONDITIONS. EXISTING UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE AND ARE TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. FA ■■ - 11111111 HDD PULL STRINGING AREA APPROX. = 812', 1 STRING SOIL BORING B-2 .. • HDD - 8" PIPELINE PLAN. 1 50 100HORIZONTAL 11N=50FT 25 20 15 10 05 00 95 90 85 w Li - cc) 80 75 70 65 .o, a1 155 50 's 45 '1 140 >I 135 19+50 20+00 BURNS & McDONNELL CONSULTANTS, INC STATE LICENSE # C-1435 rl CLAUDE A McIVIULLAN e IFC SUBMITTAL DATE °I NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP J CONTRACTOR SHALL VERIFY ALL COORDINATES AND DIMENSIONAL INFORMATION PRIOR TO CONSTRUCTION. BRING ANY DISCREPANCIES WITH LAYOUT TO ATTENTION OF COMPANY PRIOR TO STARTING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR KNOWING LOCATION OF ALL ENVIRONMENTALLY SENSITIVE AREA RESTRICTIONS PERTAINING TO THIS PROJECT. GEOTECHNICAL NOTES: GEOTECHNICAL DATA PROVIDED BY ATC GROUP SERVICES, LLC. REFER TO THE PROJECT GEOTECHNICAL BORING LOGS ON SHEETS PNG-C-027-0001140 AND PNG-C-027-0001141 FOR MORE DETAILED SUBSURFACE INFORMATION. THE GEOTECHNICAL DATA IS ONLY DESCRIPTIVE OF THE LOCATIONS ACTUALLY SAMPLED. EXTENSION OF THE DATA OUTSIDE OF THE ORIGINAL BORINGS MAY BE DONE TO CHARACTERIZE THE SOIL CONDITIONS. HOWEVER, COMPANY DOES NOT GUARANTEE THESE CHARACTERISTICS TO BE ACCURATE. CONTRACTOR MUST USE HIS OWN EXPERIENCE AND JUDGEMENT IN INTERPRETING THIS DATA. TOPOGRAPHIC SURVEY NOTES: TOPOGRAPHIC SURVEY DATA PROVIDED BY MASER CONSULTING P.A. NORTHINGS AND EASTINGS ARE IN U.S. SURVEY FEET REFERENCED TO NORTH CAROLINA STATE PLANE COORDINATES. ELEVATIONS ARE IN FEET REFERENCED TO NAVD 88. DRILL PATH NOTES: DRILL PATH STATIONING IS IN FEET BY HORIZONTAL MEASUREMENT AND IS REFERENCED TO CONTROL ESTABLISHED FOR THE DRILLED SEGMENT. DRILL PATH COORDINATES REFER TO THE CENTERLINE OF PILOT HOLE AS OPPOSED TO TOP OF INSTALLED PIPE. HORIZONTAL DIRECTIONAL DRILL PATH DEPICTS MINIMUM REQUIREMENTS ONLY. FINAL PATH TO BE DETERMINED BY CONTRACTOR AT TIME OF CONSTRUCTION. PILOT HOLE TOLERANCES: THE PILOT HOLE SHALL BE DRILLED TO THE TOLERANCES LISTED BELOW. HOWEVER IN ALL CASES, RIGHT-OF-WAY RESTRICTIONS AND CONCERN FOR ADJACENT FACILITIES SHALL TAKE PRECEDENCE OVER THESE TOLERANCES. 1. ENTRY POINT: NO MODIFICATIONS SHALL BE MADE WITHOUT APPROVAL FROM THE COMPANY ENGINEER. 411 1193 fff INNER MEN No 0 MENEM ■� ■■■■■■\ \ \ -j \ ■■■■■■ ■■■■■■ 251-00 �■'■M441-0 EE No■■SEE ■ i .26+00 y 27+00 . �8+00 ------- -_ o 2. ENTRY ANGLE: UP TO 1' INCREASE FROM THE DESIGNED ENTRY ANGLE; NO DECREASE IN ENTRY ANGLE WILL BE ALLOWED. 3. EXIT POINT: UP TO 20 FEET LONGER OR 10 FEET SHORTER FROM THE EXIT POINT; UP TO 5 FEET RIGHT OR LEFT OF THE DESIGNED ALIGNMENT. 4. EXIT ANGLE: NO INCREASE FROM THE DESIGNED EXIT ANGLE; UP TO 2° DECREASE IN EXIT ANGLE WILL BE ALLOWED. 5. ELEVATION: UP TO 2 FOOT ABOVE AND 10 FEET BELOW DESIGNED PROFILE. 6. ALIGNMENT: UP TO 5 FEET RIGHT OR LEFT OF THE DESIGNED ALIGNMENT. 7. CURVE RADIUS: NO LESS THAN 400 FEET BASED ON A 3 JOINT AVERAGE. PROTECTION OF EXISTING FACILITIES: CONTRACTOR SHALL UNDERTAKE THE FOLLOWING STEPS PRIOR TO COMMENCING DRILLING OPERATIONS: 1. CONTACT THE UTILITY LOCATION IDENTIFICATION SERVICE FOR THE CONSTRUCTION AREA. 2. POSITIVELY LOCATE AND STAKE ALL EXISTING UNDERGROUND FACILITIES. ANY FACILITIES LOCATED WITHIN 10 FEET OF THE DESIGNED PATH SHALL BE EXPOSED. 3. MODIFY DRILLING PRACTICES AND DOWNHOLE ASSEMBLIES AS NECESSARY TO PREVENT DAMAGE TO EXISTING FACILITIES. W-PKM-01 PERENNIAL STREAM PKM-02 ' ii 29+00 iiii� 30+00 31+00 sw bi�32+00vavavamw, PERENNIAL STREAM S-PKM-2 I 9 HORIZONTAL LENGTH = 800' TRUE DRILLED LENGTH = 812' NOTE: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL EXISTING UTILITIES AND OTHER STRUCTURES. CONTRACTOR SHALL BE RESPONSIBLE FOR LOSSES AND REPAIRS OCCASIONED BY DAMAGE TO FACILITIES RESULTING FROM DRILLING OPERATIONS. CONTRACTOR SHALL TAKE STEPS TO PROTECT EXISTING FACILITIES, INCLUDING, BUT NOT LIMITED TO, SETTING SURFACE CASING AS NECESSARY TO PREVENT SETTLEMENT AND DISPLACEMENT. NOTE: STRATIFICATION LINES AND SUBSURFACE MATERIAL DESCRIPTIONS SHOWN ON THIS DRAWING HAVE BEEN SIMPLIFIED FOR PRESENTATION PURPOSES. REFER TO THE PROJECT GEOTECHNICAL BORING LOGS AND REPORT FOR MORE DETAILED SUBSURFACE INFORMATION. NOTE: CONTRACTOR SHALL ACTIVELY MONITOR THE DRILLED ALIGNMENT FOR IMPACTS THAT COULD OCCUR AS A RESULT OF HDD OPERATIONS (I.E. SETTLEMENT, HEAVE, AND DRILLING FLUID FLOW). CONTRACTOR'S MONITORING PROCEDURES AND ASSOCIATED EMERGENCY RESPONSE PLANS SHALL BE APPROPRIATE TO ENSURE THAT PUBLIC SAFETY IS NOT COMPROMISED. I PROPOSED TEMPORARY HDD WORKSPACE SOIL BORING B-3 STA:33+82 OFF:71'L 33+00 34+00 o ■■NNEN 1MEN 1 O n i cal ■■■■■■1 ■ 1■■ ■■■■■r ~ 35+00 ■■■■�■■■� i■■■■ N / .0-0-0-0- 9 to HDD ENTRY AT 12' - - - - - - - - - - -0.5 -2 0 - - - - - - - - - HDD EXIT AT 12' STA:26+86 EL:106' ELEV:116' --- - -- - -8.0 PROPOSED 8" PE DISTRIBUTION MAIN 0.5 -2.0 \ EXISTING GRADE i - -13.0 ` ' -4.0 g I _0 i -18.0 -13.0.:::: -23.0 77 - - � I -28.0 - - - 0 � -25.0 SOIL BORING SEE PNG-C-027-0001140 B-2 -30.0 SOIL BORING B-3 SEE PNG-C-027-0001141 -35.0 -36.0 \ �� \ -42.3 '\ - - DESIGNED DRILL PROFILE 8" HDPE DISTRIBUTION MAIN PT / EXIT CURVE STA:28+93 ELEV:62' PC / EXIT CURVE STA:29+77 ELEV:53' _ - - - -40.0 -48.5 , /\I 'T R=400' -45.0 -53.5 N N PC /ENTRY CURVE STA:32+32 ELEV:62' ` -50.0 -58.5 A -55.0 HDD - 8" PIPELINE -63.5 \ -60.0 -68.5 172' ` PROFILE ` -65.0 0 50 100 HORIZONTAL 1IN = 50FT 0 10 20 VERTICAL 1IN = 1OFT -75.0 PT / ENTRY CURVE STA:31 +49 ELEV:53' -70.0 PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO. DATE REVISION(S) DESCRIPTION BY CHK APPD DESCRIPTION APPROVALS tural f•aPiedmont DUN E 0111 Na COPYRIGHT 2018 BELLAMY LAKE ROAD DOT RELOCATION HDD DETAIL SHEET 2 - FISHING CREEK E N F I E LD NORTH CAROLINA TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA A 10-16-2020 ISSUED FOR 90% REVIEW MJD ARR CAM AREA CODE 1910 DATE NIA INITIALS N/A REGIONAL ENGINEER ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DATE NIA INITIALS N/A MGR TECH REC &STD DRAWING BY MJD STATION ID DATE 10/16/2020 INITIALS CAM PRINCIPAL ENGINEER CHECKER INITIALS ARR 34+00 35+00 REF. DWG(S) PNG-G-027-XXXXXX1 125 120 115 110 105 100 95 90 85 w Lj- 80 0 a 75 70 65 60 55 50 45 40 35 35+50 SHEET(S) 9 OF 20 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION PNG-C-027-0001124 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A. McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP EXISTING 8" DISTRIBUTION MAIN RETIRE 8" DISTRIBUTION MAIN 5'-0" 5 2 - - - - - - - - - - Ell - - - - - - - - - - - 4 1 I 1 DETAIL SCALE: NTS WEST TIE-IN RETIRE 8" DISTRIBUTION MAIN EXISTING 8" DISTRIBUTION MAIN 5 5'-0" 2 DETAIL 2 SCALE: NTS EAST TIE-IN *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS I ARR APPROVALS DATE INITIALS N/A NIA REGIONAL ENGINEER DATE INITIALS MGR TECH N/A NIA REC & STD DATE INITIALS PRINCIPAL 10/16/2020 CAM ENGINEER BELLAMY LAKE ROAD DOT RELOCATION V Ar DUKE N RGYy r6111 Pied ont EAST AND WEST TIE-IN DETAILS ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW SHEET(S) 10 OF 20 1 DWG SCALE NOT TO SCALE DWG DATE 10/16/2090 SUPERSEDED DRAWING NUMBER REVISIO P N G-C-027-0001125 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER i ru BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP s N: E.•23670 NAB BEGIN STA. 10+00 PARCEL NO: 01 PIN NO: 3867-00-7 KIRBY ME R DgBL/1548CPOG�/5 r H4X4 �XCONC. NA �Otl nl// N:877546.78 r[� E.• 2367384.75 OAD R,. R W HDD ENTRY ft TEMPORARY CONSTRUCTION ENTRANCE PARCEL Ivv: wvwoy PIN NO. 3867-00-77-2124 77M W. FISHER AND KAY W. FISHER DB 1684 PG 586 HALIFAX COUNTY R R R PERENNIAL STREAM S-PKM-01 RB W-PKM-03 PERENNIAL STREAM S-PKM-01 LB W-PKM-02 CAIPI C'TA AAi713 5\8" IRON RORA DN0-�'—D2-93-315 N.877468.76PIN NO. 387700034622 E.•236919W1241S CONRAD ELSIE MOZINGO NA REVOCABLE LIVING TRUST DB 2035 PG 363 NASH COUNTY. PERENNIAL STREAM S-PKM-02 ._ _ PROPOSED PERMANENT ACCESS ROAD SEE SHEET PNG-027-0001119 TEMPORARY CONSTRUCTION ENTRANCE PARCEL NO. 0402223 1" PIN NO. 387700087245 FREDERICK M. DUNN & ELAINE T. DUNN DB 1445 PG 465 HALIFAX COUNTY `7 4 4 10 j PIPELINE CONSTRUCTION PHASING 1. NOTIFY NCDEQ AT LEAST 48 HOURS PRIOR TO PROJECT MOBILIZATION. 2. CONSTRUCTION AND LAND DISTURBANCE ACTIVITIES TO BEGIN NO EARLIER THAN DECEMBER 2021. PREPARE PROPOSED LINES WITH STORMWATER BMPS. SEE PHASED APPROACH BELOW: a. PHASE I: CLEARING AND GRUBBING ROW i. INSTALL PERIMETER CONTROLS - CONSTRUCTION ENTRANCES, COMPOST SOCK, SILT FENCE ii. BEGIN CLEARING AND GRUBBING OPERATIONS. ij. HAUL OFF ALL CHIPPED WOOD TO AN APPROVED LANDFILL iii. TEMPORARY STABILIZATION WITH TEMPORARY SEEDING, SEE ES&PC PLANS iv. WHEREVER SLOPES ARE 2% OR STEEPER, TEMPORARY SEEDING SHALL BE APPLIED IMMEDIATELY FOLLOWING CLEARING AND GRUBBING. b. PHASE 2: GRADING OF ROW FOR ACCESS AND DITCH EXCAVATION i. MAINTAIN EXISTING PERIMETER MEASURES AND INSTALL ADDITIONAL PERIMETER MEASURES AS NEEDED. ii. PRIOR TO GRADING OPERATIONS INSTALL EARTHEN BERMS OR COMPOST SOCKS ALONG THE UPGRADIENT EDGE OF THE ROW TO DIVERT CLEAN WATER AROUND OR THROUGH DISTURBED AREAS. BERMS MUST BE MATTED IMMEDIATELY UPON CONSTRUCTION. iii. BEGIN GRADING ROW IN PREPARATION OF PIPE INSTALLATION. iv. DURING GRADING OPERATIONS MANAGE EROSION AND SEDIMENT CONTROL FROM WITHIN THE DISTURBED AREAS BY INSTALLING SILT FENCE OUTLETS, SEDIMENT TRAPS, ETC. INSTALL DEWATERING FEATURES AT IDENTIFIED LOCATIONS. MAKE SURE STOCKPILED MATERIAL IS PROTECTED WITH SILT FENCE ALONG THE DOWNSTREAM EDGE. v. PRIOR TO INSTALLING THE PIPE INSTALL TRENCH PLUGS IN THE OPEN DITCH IN AREAS WHERE SLOPES WARRANT TRENCH PLUGS. THE TOP OF THE DOWNSTREAM TRENCH PLUG WILL BE AT THE SAME ELEVATION AS THE BOTTOM OF THE UPSTREAM TRENCH PLUG. vi. TEMPORARY STABILIZATION OF DISTURBED AREAS WITH TEMPORARY SEEDING AND MATTING, SEE ES&PC PLANS. c. PHASE 3: PIPE INSTALLATION i. MAINTAIN INSTALLED EROSION AND SEDIMENT CONTROL MEASURES. ii. MAINTAIN DEWATERING OPERATIONS OF OPEN DITCH. iii. BEGIN PIPE INSTALLATION OPERATIONS WHICH INCLUDE STAGING OF PIPE, WELDING OF PIPE, AND LOWERING OF PIPE INTO THE OPEN DITCH. iv. AS PIPE IS INSTALLED DITCH IS TO BE BACKFILLED AND IMMEDIATELY PERMANENTLY STABILIZED WITH PERMANENT SEEDING. v. IN AREAS OF PROPOSED TRENCH PLUGS, SEDIMENT WITHIN THE DITCH TRAPPED BEHIND THE TRENCH PLUGS SHOULD BE REMOVED, TRENCH PLUGS SHALL BE TEMPORARILY REMOVED, PIPE IS TO BE INSTALLED, AND TRENCH PLUGS ARE TO BE REINSTALLED. 3. FOLLOWING CONSTRUCTION ACTIVITIES, AND AFTER INSPECTION BY NCDEQ, REMOVE TEMPORARY EROSION AND SEDIMENT CONTROL BMPS, AND SEED ANY AREAS DISTURBED DURING BMP REMOVAL ACCORDING TO THE SPECIFICATIONS IN APPENDIX D; SEE BELOW: a. PHASE 4: FINAL CONDITIONS i. CONTINUE STABILIZING DISTURBED AREAS. ii. CONTRACTOR TO PROVIDE SEED, FERTILIZER, SOIL AMENDMENTS, AND WATER UNTIL PERMANENT VEGETATION IS ESTABLISHED IN ACCORDANCE TO NCDEQ STANDARDS. iii. CONTRACTOR TO RETURN CULTIVATED FIELDS TO ORIGINAL CONDITIONS. iv. ONCE AREAS ARE PERMANENTLY STABILIZED IN ACCORDANCE TO NCDEQ STANDARDS AND CULTIVATED FIELDS ARE RETURNED TO ORIGINAL CONDITIONS, REMOVE REMAINING E&SC MEASURES AND CLOSE PERMIT IN ACCORDANCE TO NCDEQ REQUIREMENTS 4. UPON ESTABLISHMENT OF PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION, AN INSPECTION BY THE DEMLR-LQS SHALL BE REQUESTED TO VERIFY THE ADEQUACY OF THE GROUND COVER. PERMIT COVERAGE WILL END UPON ELECTRONIC SUBMITTAL OF THE NOTICE OF TERMINATION (NOT). PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO. DATE REVISION(S) DESCRIPTION BY CHK APPD I DESCRIPTION APPROVALS �jDUKEPiedmont ENERGY: 0111 Natural Gas COPYRIGHT 2018 BELLAMY LAKE ROAD DOT RELOCATION OVERALL ES&PC PLAN ENFIELD NORTH CAROLINA � TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA A 10-16-2020 ISSUED FOR 90% REVIEW LLO JTG CAM AREA CODE 1910 DATE N/A INITIALS N/A REGIONAL ENGINEER ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DATE N/A INITIALS N/A MGR TECH REC&STD DRAWING BY LLO STATION ID DATE 10/16/2020 INITIALS CAM PRINCIPAL ENGINEER CHECKER INITIALS JTG 0 200' 400' SCALE IN FEET LIMITS OF DISTURBED AREA PIPELINE PROJECT: 3.20 AC POINT OF CONTACT (MAINTENANCE): BRANDON TAYLOR (XXX)-XXX-XXXX PRELIMINARY - NOT FOR CONSTRUCTION 90% DESIGN SUBMITTAL SHEET(S) 11 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION PNG-C-027-0001127 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER GENERAL EROSION AND SEDIMENT CONTROL NOTES CONSTRUCTION SEQUENCE (SITE) a. INITIAL INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES; 1. THIS PROJECT IS LOCATED IN THE TAR-PAMLICO RIVER BASIN. (PHASE 1) b. CLEARING AND GRUBBING OF EXISTING GROUND COVER; RECEIVING WATERS: FISHING CREEK; BELLAMY LAKE CLASSIFICATION: WS-IV;NSW 1. CONTACT THE DEMLR RALEIGH REGIONAL OFFICE AT LEAST 48 HOURS PRIOR C. COMPLETION OF ANY GRADING THAT REQUIRES GROUND COVER; TO COMMENCING THE LAND -DISTURBING ACTIVITY. THE CONTACT NUMBER 2. CONSTRUCTION ACTIVITY POLLUTION PREVENTION IS REQUIRED FOR THIS IS (919) 791-4200. d. COMPLETION OF ALL LAND -DISTURBING ACTIVITY, CONSTRUCTION, OR PROJECT. PREVENTION OF POLLUTION RESULTING FROM CONSTRUCTION DEVELOPMENT, INCLUDING PERMANENT GROUND COVER ESTABLISHMENT ACTIVITIES SHALL BE ACCOMPLISHED BY CONTROLLING SOIL EROSION, 2. INSTALL CONSTRUCTION ENTRANCE(S) AS SHOWN ON PLAN SHEETS WHERE AND REMOVAL OF ALL TEMPORARY MEASURES; AND WATERWAY SEDIMENTATION, AND AIRBORNE DUST GENERATION. EQUIPMENT WILL ENTER AND LEAVE THE PROJECT SITE. CONTRACTOR SHALL ENSURE THAT NO SEDIMENT RESULTING FROM e. TRANSFER OF OWNERSHIP OR CONTROL OF THE TRACT OF LAND WHERE CONSTRUCTION ACTIVITIES INFRINGES ONTO ADJACENT PROPERTIES. 3. INSTALL EROSION CONTROL DEVICES. THE EROSION AND SEDIMENTATION CONTROL PLAN HAS BEEN APPROVED CONTRACTOR SHALL COORDINATE EROSION AND SEDIMENT CONTROL WITH AND WORK HAS BEGUN. THE NEW OWNER OR PERSON IN CONTROL SHALL OTHER CONSTRUCTION ENTITIES PERFORMING WORK ON ADJACENT 4. STABILIZE DISTURBED AREAS WITH EROSION CONTROL DEVICES. UTILIZE CONDUCT AND DOCUMENT INSPECTIONS UNTIL THE PROJECT IS PROPERTIES. TEMPORARY SEEDING AS NECESSARY. PERMANENTLY STABILIZED AS SET FORTH IN SUB -ITEM (C) OF THIS ITEM. 3. SOIL EROSION AND SEDIMENT CONTROLS ARE MEASURES USED TO REDUCE 5. CONTACT INSPECTOR FOR ONSITE INSPECTION OF INSTALLED EROSION 2. DOCUMENTATION OF SELF -INSPECTIONS PERFORMED UNDER ITEM (1) OF THE AMOUNT OF SOIL PARTICLES THAT ARE CARRIED OFF AN AREA AND CONTROL DEVICES. THIS RULE SHALL INCLUDE: DEPOSITED INTO A DRAINAGE COLLECTION SYSTEM OR INTO A BODY OF WATER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT 6. MAINTAIN DEVICES AS NEEDED PER NCDEQ MAINTENANCE INSTRUCTIONS. a. VISUAL VERIFICATION OF GROUND STABILIZATION AND OTHER EROSION EROSION AND SEDIMENTATION ARE CONTROLLED TO THE EXTENT CONTROL MEASURES AND PRACTICES AS CALLED FOR IN THE APPROVED PRACTICABLE. ALL APPLICABLE SOIL EROSION AND SEDIMENT CONTROL 7. ALL BARE SOILS ARE TO BE STABILIZED UNDER CONDITIONS OUTLINED IN THE PLAN; MEASURES SHALL BE IMPLEMENTED AND MAINTAINED THROUGHOUT THE CURRENT NPDES PERMIT OR, IF IT IS IN A CRITICAL AREA, BY THE END OF THE DURATION OF CONSTRUCTION ACTIVITIES. PRIOR TO INITIATING DAY. b. VERIFICATION BY MEASUREMENT OF SETTLING BASINS, TEMPORARY CONSTRUCTION IN AN AREA, ALL TEMPORARY EROSION AND SEDIMENT CONSTRUCTION ENTRANCES, ENERGY DISSIPATORS, AND TRAPS. CONTROL PRACTICES SHALL BE IN PLACE. UPON PROJECT COMPLETION AND 8. SELF -INSPECTIONS FOR EROSION AND SEDIMENTATION CONTROL MEASURES PERMANENT STABILIZATION, ALL TEMPORARY SOIL EROSION AND SEDIMENT ARE TO BE PERFORMED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS AND c. THE NAME, ADDRESS, ORGANIZATION AFFILIATION, TELEPHONE NUMBER, CONTROL MEASURES SHALL BE REMOVED. WITHIN 24 HOURS OF EVERY RAIN EVENT OF GREATER THAN 1 INCH. ANY AND SIGNATURE OF THE PERSON CONDUCTING THE INSPECTION AND THE NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN MEASURES AS DATE OF THE INSPECTION SHALL BE INCLUDED, WHETHER ON A COPY OF 4. TEMPORARY EROSION CONTROL SHALL BE THE CONTRACTOR'S DESIGNED. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED IN THE THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN OR AN RESPONSIBILITY, WHO SHALL UTILIZE APPROPRIATE BEST MANAGEMENT CONSTRUCTION DETAILS ON THIS PLAN. A RAIN GAUGE SHALL BE INSTALLED INSPECTION REPORT. A TEMPLATE FOR AN EXAMPLE OF AN INSPECTION PRACTICES (BMPS). THOSE BMPS SHALL CONSIST OF SILT FENCE, WATTLES AT THE PROJECT SITE FOR MONITORING. AND MONITORING REPORT IS PROVIDED ON THE DEMLR WEBSITE AT: OR OTHER MEANS TO CONTROL EROSION AS NEEDED. HTTPS://DEQ.NC.GOV/ABOUT/DIVISIONS/ENERGY-MINERAL- (PHASE 2 & 3) LAN DRESOURCESIEROSION-SEDIMENT-CONTROL/FORMS. ANY RELEVANT 5. CONTRACTOR SHALL PLACE SILT FENCE PRIOR TO BEGINNING WORK. THE LICENSES AND CERTIFICATIONS MAY ALSO BE INCLUDED. ANY DEVICES SHALL BE PLACED DOWN -SLOPE OF DISTURBED AREAS WHERE 1. BEGIN ACCESS ROAD INSTALLATION ON THE SITE AND SITE EXPANSION. DOCUMENTATION OF INSPECTIONS THAT OCCUR ON A COPY OF THE SHEET EROSION WOULD OCCUR. SILT FENCE SHALL BE CLEANED AND APPROVED EROSION AND SEDIMENTATION CONTROL PLAN SHALL OCCUR REPAIRED WHEN SEDIMENT BUILDUP REACHES ONE-THIRD OF SILT FENCE 2. MAINTAIN ALL EROSION CONTROL DEVICES PER NCDEQ MAINTENANCE ON A SINGLE COPY OF THE PLAN AND THAT PLAN SHALL BE MADE HEIGHT. AFTER SIGNIFICANT RUNOFF EVENTS (1" OF RAINFALL OR MORE) INSTRUCTIONS. AVAILABLE ON THE SITE. AND ON A WEEKLY BASIS, THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL STRUCTURES FOR SILT BUILD-UP THAT INTERFERES WITH THE 3. STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISH GRADE WITH d. A RECORD OF ANY SIGNIFICANT DEVIATION FROM ANY EROSION OR PERFORMANCE OF THE EROSION CONTROL STRUCTURE AND REPAIR OR VEGETATION, GRAVEL, ETC. SEDIMENTATION CONTROL MEASURE FROM THAT ON THE APPROVED PLAN. REPLACE THOSE STRUCTURES, AS NECESSARY. FOR THE PURPOSE OF THIS RULE, A "SIGNIFICANT DEVIATION" MEANS AN 4. ALL EROSION CONTROL DEVICES SHALL REMAIN IN PLACE AS SHOWN ON THE OMISSION, ALTERNATION, OR RELOCATION OF AN EROSION OR 6. ALL STORM DRAIN INLETS SHALL BE PROTECTED BY APPROPRIATE BMPS DRAWINGS UNTIL THE ENTIRE SITE IS PERMANENTLY STABILIZED AND SEDIMENTATION CONTROL MEASURE THAT PREVENTS IT FROM DURING CONSTRUCTION, UNTIL ALL SOURCES WITH POTENTIAL FOR APPROVED BY THE NCDEQ INSPECTOR. PERFORMING AS INTENDED. THE RECORD SHALL INCLUDE MEASURES DISCHARGE TO THE INLETS HAVE BEEN STABILIZED. REQUIRED TO CORRECT THE SIGNIFICANT DEVIATION, ALONG WITH 5. GROUNDCOVER SHALL BE ESTABLISHED IN 90 CALENDAR DAYS. HOWEVER, DOCUMENTATION OF WHEN THOSE MEASURES WERE TAKEN. DEVIATIONS 7. ALL EXISTING DRAIN INLETS SHALL HAVE INLET PROTECTION INSTALLED IN NPDES GROUNDCOVER REQUIREMENTS TAKE PRECEDENCE. FROM THE APPROVED PLAN MAY ALSO BE RECOMMENDED TO ENHANCE ACCORDANCE WITH NORTH CAROLINA MANUAL FOR EROSION CONTROL. THE INTENDED PERFORMANCE OF THE SEDIMENTATION AND EROSION EROSION PROTECTION MAY BE REMOVED WHEN VEGETATION IS 6. WHEN CONSTRUCTION IS COMPLETE AND ALL AREAS ARE STABILIZED CONTROL MEASURES. ESTABLISHED. COMPLETELY, ARRANGE FOR FINAL INSPECTION WITH THE NCDEQ INSPECTOR. 8. IN ACCORDANCE WITH SECTION II.B.2 OF THE NPDES GENERAL PERMIT, ANY DISTURBED AREA LEFT EXPOSED SHALL BE STABILIZED WITH TEMPORARY 7. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR SEEDING WITHIN 7 TO 14 DAYS IN ACCORDANCE WITH NORTH CAROLINA TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL SECTION THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL 6.11. PERMANENT STABILIZATION SHALL BE ACHIEVED THROUGH PERMANENT VISIT DEQ.NC.GOV/NCG01 TO SUBMIT AN ELECTRONIC NOTICE OF SEEDING FOR ALL DISTURBED AREAS. SEE SEEDING SCHEDULE IN NORTH TERMINATION (E-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN CHARGED UNTIL THE E-NOT HAS BEEN FILLED OUT. MANUAL SECTION 6.11. 9. AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED AND APPROVED BY NCDEQ, TEMPORARY EROSION AND SEDIMENTATION CONTROLS MUST BE REMOVED. AREAS DISTURBED DURING REMOVAL OF THE CONTROLS MUST BE STABILIZED WITH PERMANENT SEEDING AS SOON AS POSSIBLE WITHIN 14 CALENDAR DAYS. 10. PER NPDES REQUIREMENTS, A RAIN GAUGE, SELF -INSPECTIONS RECORDS, PERMIT, CERTIFICATE OF COVERAGE, AND S&E PLAN ARE REQUIRED TO BE MAINTAINED ON SITE AND ACCESSIBLE DURING INSPECTION. IT IS RECOMMENDED THAT THESE ITEMS BE PLACED IN A PERMITS BOX AT THE BEGINNING OR ENTRANCE OF PROJECT. 11. THE CONTRACTOR SHALL CONDUCT SELF -INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES AND COMPLETE THE DUKE ENERGY PROVIDED SELF -INSPECTION FORM. TWELVE MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON -SITE AND AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A. McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP 8. IF SITE IS APPROVED, REMOVE EROSION CONTROL MEASURES AND STABILIZE RESULTING BARE AREAS IMMEDIATELY. SELF -INSPECTION REPORT FOR LAND DISTURBING ACTIVITY AS REQUIRED BY NCGS 113A54.1 (E) (EFFECTIVE OCTOBER 1, 2010; READOPTED EFFECTIVE APRIL 1, 2020) 15A NCAC 04B .0131 SELF -INSPECTIONS ALL LAND -DISTURBING ACTIVITIES REQUIRED TO HAVE AN APPROVED EROSION AND SEDIMENTATION CONTROL PLAN UNDER G.S. 113A54.1(E) SHALL CONDUCT SELF -INSPECTIONS FOR INITIAL INSTALLATION OR MODIFICATION OF ANY EROSION AND SEDIMENTATION CONTROL DEVICES AND PRACTICES DESCRIBED IN AN APPROVED PLAN. IN ADDITION, WEEKLY AND RAIN -EVENT SELF -INSPECTIONS ARE REQUIRED BY FEDERAL REGULATIONS, THAT ARE IMPLEMENTED THROUGH THE NPDES CONSTRUCTION GENERAL PERMIT NO. NCG 010000. 1. FOR SELF -INSPECTIONS REQUIRED PURSUANT TO G.S. 11 3A-54.1 (E), THE INSPECTION SHALL BE PERFORMED DURING OR AFTER EACH OF THE FOLLOWING PHASES OF THE PLAN; PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK JAPPD DESCRIPTION LLO JTG CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY LLO STATION ID CHECKER INITIALS JTG APPROVALS DATE INITIALS REGIONAL B E L LA M Y LAKE ROAD DOT RELOCATION N/A NIA ENGINEER DATE INITIALS MGR('DUKE 0111.Piedmont ES&PC GENERAL NOTES N/A N/A REC TECH ENERGY REC&STD ENFIELD, NORTH CAROLINA DATE INITIALS 10/16/2020 CAM PRINCIPAL ENGINEER COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA SHEET(S) 12 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION P N G-C-027-0001128 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER FM / � I ru PNG GAS LINE .''/ / / ,Inlnul , / i I III 1"IRON ROD FOUND N:877568.47 E. 2368077.35 / I . \I II IIIII I I I 1 I I I I lirlllllll l I I• I I \ 1 I 1 / � \it 11 It 1E BORiivG B-1 \—_ I I I I I I I '/ '/ ' \\ \\ \\ \\ \\ — cT / i 1 �`--- ---- i / / , � I _—ram ^0 ——.�I/�L+71 � �i 1 _ \ _ 1091 '�� , I , I IIIIII I I / , \ \ \ \ \ Ili IIII \ \\ \ \ \ / I /' // / / / / / __ � ��_ 1 OFF: / / � I � I rI I "�- / 1-------� I IIIII , I I / 1 \ \ \ I IIII I I , 1 1 1 I I ' / / / ' —�� , i A i`--Y=— �F� ■ r �`` / --- I 1 )` _ —.___ NIIIIII , 1 1 1 1 1 \ \ \ \IIII 1 IIII 11I I � ; I I l / / / / / / / `�/ ♦ ♦ // i'' �'' �x1 , _'�— /' ♦ �\ � ` ` �` \ L = III-- ' ' I( pIIIIIIIII 1 , 1 I I 1 1 II I II / 1 I ` I I I IIII I 1 1 1 1 1 , III I I I I / / / I / / / �' 1 I / f III IIII I 1 I 1 , 1 I I I I I II I I III / / / / I / / // / % % % / /"' ' ' /� � I I � I � � 1 I 1 ! � � i / � �---------- / PIN: 3867-00-86-4556 /------------ it / WETLANDS I I 11 ILII ,� /^� T� T� 1 1 _' A ' ,'—---------- ,, , I I I I I I I II y I i I �b I 1 I i I 1 1 I IIII I I 1 I I I 1 I III 1 g 1 I I I I' 1 I 1 I l T /� /_ _ 1'/ i 1x i 1 I 1 I I I I I I I I l l l // 1 A h\� �3----- I I IIIII I I I I I I I I I 1 1 I I / I / I 1 1 /,., l / l, / , ,' , i' r A ,' , Oil 9 I I I I / TEMPORARY SILT FENCE, TYP',, 1 / 1 , � I I I� I I IIIIII I I I I I I I I I 1 1 I I I I I III 1 / , I / i 1 // • - / / % \ I-1I,1 �— I IIII I I I I I I II III 1 1 '— ,' o LOD �� -� �LC� r r / ,�- L�jg�Q�, LOD -- SR B D -- -- LOD - SFWB - LO / -�-- SFWB LOD - / I 1 1 1 I I I I II 1 / __ 1 / l l l 1' l / �� � �I�� IIIII ry� I , I I II kII 11 y I/ �j I, i / �_ ` p )+ \ OLIO ,� I �, IIIIII I �5`1"I I IIII I I I IIII IT��I I� L�D I 1 J T0� '�$ Y 70D—f r�� �Ch L j- — \\I �Jg /' I / �' I I111 � �`x r�-r r -6�V\ r. �� j111 I I I I I i I 11 / r �l (i i�i I li i i - / // L'� � \ c�{Air I I I r LODE III 1 11 \, I I I I I fl ' / \ O I I I111 , 1 1 1 I I ? I I IIII I I I /LOj /. /^( / -� \ \ \ \ I � a' �' III IIII , 1 1 I I I III I,I I I I , / I I . T771 % �T o \ \ 1 , / I, 1 1 I I I I I I I I I 1 / l / l�,3HDD ENTRY 1 , / I 1 - ,l I l 1 1 l 1 I I I / .' 1 _-- / 1 \ ob II I I 11 I 11 11 IIIIIII1111 j I I I I I I I I I I IIII IIIII lI ly 1 I I _ \ ' I / I �I \ \ 1 9' I I � 1 II IIII 1 1 I I I I , I I I I I IIII III j I /'r/ / i II l ' l'// I r( 1 I 1 I � � � //����g ��o I� � /� I I I I .' o -1 LOD---ram 1 , , `� �� 1 1 AW I I I I II�M� IIIIII I , .1 l l I I r I /I-IIOD �-I-�- �OD----L D , --LOD----LOD -- LOD - �;►�=LOD-----LO --=� LOD--- I , YIIII III 1 I I I I I I I I II Ili, t i l l i / 1 I / //! 1 _ I I I I I I ( I / I' ' � / ' i I 1 1 I 1 TEMPORARY CONSTRUCTION i it 'I i1 I 1 / i i �l¢l / i l HDD EXIT 1 I ,�, I / �� /I / / / l WATTLE BARRIER, TYP / ENTRANCE, SEE DETAIL 1 ON , , I ! SOIL BORING B-2 SHEET PNG-C-027-0001130 i I �� �� li l l STA:22+44 PIN: 3867-00-77-2124 I I I OFF:36'R W-PKM-01 i I IIIIII IIII \\ \ \ \ \--184--------_ ' / / ' i ' , , ' / I I I PIN: 3867-00-86-4556 \ ,�� _�---�,. ,.� /� / �, � PIN: 3877-00-03-4622 7�Fv 1 K/ I�IlIlIlIlIlIlIlIlIlIl 1 \ \ l I I I 1 I I If�111111I111\I TEMPORARY SILT FENCE, TYP \\ ` \\ \\\ �`\ \\ \\ ,g ,,'' i �' \ `� ` i� I I ; II ►olllulllml HDD EXIT 1 \ . �i � —� 1 I I � ---f' I I I\ y I \• I IIII IIII III I �\ `� \ \ ` \ \ L `' 1 IRi . 1"IRON Rff FGWD`, 8-7 47.4Q Q L�� M �� \ \\\ \i C 1 I zs�6.00, • ` `v" �. I I I I I I I /' Illllulllll/ lI ••• SFWB `�* L SFWB I y LC7 o (('��� JD� �� IIII IIII IIII 3/ +C- I II IIII IIN ``ZOD-- \ �\ \ a2\� 3� \ ♦ ` `� \ `� �� �� \� 1`� \\�^��j��\ \\ O_ \`� \ I 1 I I i' lift Ililt IIII BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP L\ \ p 1 `� l IOIIIIIIIIIII / 1 \ 1 WATTLE BARRIER, TYP WETLANDS \ ` \\1 I 1 1 I i ' Blllmliii� cO ram] r°e A �Pl \ 1 1 I I I ,I IIII IIII I T I PROPOSED PERMANENT ACCESS ROAD SEE SHEET PNG-027-0001119 I I I I I I ■ C / 416. i I .\ I, I I I PIN: 3877-00-08-7245 14\ 1 1 I \ , I \ I \ N1AT CH "NE NE 36+50 O PIN: 3877-00-08-7245 -� \�SQIL\\BbF AGI\B\\3 LOD J LOD II11 I IILOD I - -�0D3 G�GIo iJ-TLltJ \ ��3 0�\ ���\ 35+ llla 1 1 ; I I 6.38 /01 1 I I ' ' p (I� I \ \ �I I 11 I 1 I j l l N �� 1 L0� - L -1- T LOQ - I-, LODI � Lfl� ��\ I 1 I II I I I I j I 1 OD T O \ \ I\ \ o I� k r I O , 0 , I' 1 00 1 II II I -- LOD 111 I i) i I I I I L�\ .� \`.\� \.\ \�\ \\ \\ \ `\ HDD ENTR� IIIIIII I I I 1 1 If 49 INIIIIIII ' I� _ • \ \ ` \\ \\ ` \ ` ` \\ II IIII gillIII I \ \ \ \ o • �I I � Ijd I 1 I I 1 , I I I • I ri TEMPORARY CONS - ENTRANCE, SEE DE II SHEET PNG-C-027-0 ---14, P; FIN L I I` I , I 1 1 1 1 I 1 KinTF.q- 1. CONTRACTOR SHALL INSTALL CONSTRUCTION EXIT AT ALL SITE ACCESS POINTS. 2. ALL TREES TO REMAIN SHALL BE PROTECTED WITH TREE PROTECTION FENCING. 3. ANY DISTURBED AREA LEFT IDLE FOR A PERIOD OF 14 DAYS OR LONGER SHALL BE STABILIZED WITH MULCHING AND O 1 TEMPORARY SEEDING WITH THE EXCEPTION OF + AGRICULTURAL FIELDS WHICH ONLY NEED STABILIZATION co I TO THE EXTENT REQUIRED TO AVOID TOP SOIL WASHING Z AWAY. SEE DETAIL 1, SHEET C-027-0001131. J = 4. STABILIZE ALL DISTURBED AREAS OUTSIDE OF THE U Q CULTIVATED FIELD WITH PERMANENT SEEDING IN 2 1 ACCORDANCE WITH DETAIL 2, SHEET C-027-0001131. ALL OTHER DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITIONS AS A CULTIVATED FIELD; PERMANENT SEEDING WILL NOT BE UTILIZED. 5. REFER TO SITE PLAN PNG-C-027-0001127 FOR OVERALL LIMITS OF DISTURBANCE, HDD ENTRY AND EXIT WORKSPACE, AND TEMPORARY AND PERMANENT ACCESS ROADS. 6. CONTRACTOR SHALL CLEAR TREES TO STUMPS ONLY (GROUND LEVEL OR WATERLINE); NO GRUBBING IN HDD REQUIRED. CONTRACTOR SHALL PULL ALL CUT MATERIAL OUT OF HDD ROW AND DISPOSE OF AS DIRECTED BY COMPANY. HAND CLEARING IS ALLOWED. IF EQUIPMENT IS USED, MATTING AND EROSION CONTROL MEASURES SHALL BE IN PLACE TO SATISFACTION OF COMPANY. LEGEND: FI' PROPERTY LINE 2 TEMPORARY SILT FENCE C-027-0001130 — — — LOD-- LIMITS OF DISTURBANCE N__J 3 ••• RIGHT-OF-WAY DIVERSION C-027-0001131 STREAM �J 1 0 o TEMPORARY CONSTRUCTIO ENTRANCE C-027-0001130 N�� WETLANDS TIMBER MATS L-) C-027-0001132 4 WATTLE BARRIER C-027-0001130 PROPOSED 8 PIPELINE �J 8+00 9+00 3 SFWB SILT FENCE WATTLE BREAK C-027-0001130 N�� LIMITS OF DISTURBED AREA PIPELINE PROJECT: 3.20 AC POINT OF CONTACT (MAINTENANCE): PRELIMINARY - NOT BRANDON TAYLOR (XXX)-XXX-XXXX FOR CONSTRUCTION 90% DESIGN SUBMITTAL PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK JAPPD DESCRIPTION APPROVALS LLO JTG CAM AREA CODE 1910 DATE N/A INITIALS N/A REGIONAL ENGINEER ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DATE N/A INITIALS N/A MGR TECH REC & STD DRAWING BY LLO STATION ID DATE 10/16/2020 INITIALS CAM PRINCIPAL ENGINEER CHECKER INITIALS JTG BELLAMY LAKE ROAD DOT RELOCATION ,(''DUKE 011INatural Piedmont ES&PC PLAN ENERGY: Gas ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA 0 50 100 00119 1IN = 50FT SHEET(S) 13 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION PNG-C-027-0001 1 29 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER INSTALLATION NOTES: —AGGREGATE SIZE: 2-3" DIAMETER WASHED STONE. —PAD THICKNESS: 6" MINIMUM. —PAD WIDTH: 24' MINIMUM. —PAD LENGTH: 100' MINIMUM. —PAD LOCATION: LOCATE CONSTRUCTION ENTRANCES AND EXITS TO LIMIT SEDIMENT FROM LEAVING THE SITE AND TO PROVIDE MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. AVOID STEEP GRADES AND ENTRANCES AT CURVES IN PUBLIC ROADS. FILTRATION GEOTEXTILE TO STABILIZE FOUNDATION (ESPECIALLY IMPORTANT WHERE SOFT SOIL IS ANTICIPATED) 2-3" DIAMETER WASHED STONE, 6" DEEP PERSPECTIVE VIEW DETAIL SCALE: NTS GRAVEL CONSTRUCTION ENTRANCE ISOMETRIC VIEW BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A MCMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP MAINTENANCE NOTES: —MONITOR DAILY TO SUPPLEMENT STONE TO ENSURE ENTRANCE FUNCTIONS PROPERLY. —CLEAN ANY MATERIAL TRACKED ONTO PUBLIC ROADWAY IMMEDIATELY. —SCHEDULE ROUTINE SWEEPING AT THE END OF EACH WORK DAY. —WASHING: IF CONDITIONS AT THE SITE ARE SUCH THAT MOST OF THE MUD AND SEDIMENT ARE NOT REMOVED BY VEHICLES TRAVELING OVER THE GRAVEL, THE TIRES SHOULD BE WASHED. WASHING SHOULD BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE THAT DRAINS INTO A SEDIMENT TRAP OR OTHER SUITABLE DISPOSAL AREA. A WASH RACK MAY BE USED TO MAKE WASHING STONE MORE CONVENIENT AND EFFECTIVE. INSTALLATION NOTES: —USE MINIMUM 12 IN. DIAMETER EXCELSIOR WATTLE AND LENGTH OF 10 FT. —EXCAVATE A 1 TO 2 INCH TRENCH FOR WATTLE TO BE PLACED. —DO NOT PLACE WATTLE ON TOE OF SLOPE. —OFFSET SLIGHTLY OFF TOE. —USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL CROSS SECTION. —INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO GROUND. —PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. —INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. INSET A FILL SLOPE VIEW FROM SLOPE DETAIL 3 SCALE: NTS SILT FENCE WATTLE BREAKS 1"-2" TRENCH SIDE VIEW PLASTIC CAP 6' MAX. WITH WIRE OVER POST INSTALLATION NOTES 4' MAX FOR TROUT WATERS —USE FILTRATION GEOTEXTILE A MINIMUM OF 36" IN WIDTH AND FASTEN ADEQUATELY TO THE POSTS AND WIRE AS DIRECTED. —USE WIRE A MINIMUM OF 32" IN WIDTH AND WITH A MINIMUM MIDDLE AND VERTICAL WIRES OF 6 LINE WIRES WITH 12" STAY SPACING. SHALL BE 121/2 GAUGE MIN. —PROVIDE 5'-0" STEEL POST OF THE SELF —FASTENER ANGLE STEEL TYPE. —FOR MECHANICAL SLICING METHOD INSTALLATION, GEOTEXTILE TOP AND BOTTOM STRAND SHALL BE A MAXIMUM OF 18" ABOVE GROUND SURFACE. SHALL BE 10 GAUGE MIN. T248" MAX. " MIN.) MAINTENANCE NOTES: —REMOVE AND DISPOSE OF SILT ACCUMULATIONS WHEN THE DEPTH REACHES ONE—HALF OF THE HEIGHT OF THE WATTLE. —REPLACE OR CLEAN THE WATTLE AS NEEDED TO ALLOW RUNOFF TO SLOWLY DEWATER THROUGH THE DEVICE BETWEEN RAIN EVENTS. —MONITOR THE WOODEN STAKES AND STAPLES TO ENSURE THAT THE WATTLE REMAINS SECURELY ANCHORED AFTER RAIN EVENTS. —MONITOR THE WATTLE/SILT FENCE OVERLAP TO ENSURE THIS INTERFACE REMAINS SECURELY SEALED AFTER RAIN EVENTS. SILT FENCE POST = INSET A DOWNSLOPE STAKE I F7I GI ........l..l..--..1--...--...�--.. GEOTEXTILE. . �.r. r-.. r..-..--...--...--...--...--' �..--...--...-- ...--...--...-. _..-... MAINTENANCE NOTES: —REMOVE AND DISPOSE OF SILT ACCUMULATIONS WHEN THE I FI I A I I A '-' DEPTH REACHES ONE—HALF OF THE HEIGHT OF THE WIRE GEOTEXTILE. —REMOVE AND REPLACE DETERIORATED OR CLOGGED FILTRATION GEOTEXTILE FI LTR EXTENSION OF GEOTEXTILE AND WIRE INTO TRENCH DETAIL 2 SCALE' NTS TEMPORARY SILT FENCE 4- ISOMETRIC VIEW FRONT VIEW INSTALLATION NOTES: —USE MINIMUM 18 IN. NOMINAL DIAMETER EXCELSIOR WATTLE AND LENGTH OF 10 FT. —EXCAVATE A 2 TO 3 INCH TRENCH FOR WATTLE TO BE PLACED. —DO NOT PLACE WATTLES ON TOE OF SLOPE. —USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL CROSS SECTION. —INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO GROUND. —PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. —INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. —FOR BREAKS ALONG LARGE SLOPES (HEIGHT OF 15' OR MORE MEASURED ALONG THE SLOPE), USE MAXIMUM SPACING OF 25 FT. wi DETAIL 4 SCALE: NTS WATTLE BARRIER FILL Wk INSET A 2"-3" TRENCH TOE OF FILL STAKE 18" WATTLE —J \—DOWNSLOPE STAKE TOP VIEW MAINTENANCE NOTES: —REMOVE AND DISPOSE OF SILT ACCUMULATIONS WHEN THE DEPTH REACHES ONE—HALF OF THE HEIGHT OF THE WATTLE. —REPLACE OR CLEAN THE WATTLE AS NEEDED TO ALLOW RUNOFF TO SLOWLY DEWATER THROUGH THE DEVICE BETWEEN RAIN EVENTS. —MONITOR THE WOODEN STAKES AND STAPLES TO ENSURE THAT THE WATTLE REMAINS SECURELY ANCHORED AFTER RAIN EVENTS. PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK JAPPID DESCRIPTION APPROVALS LLO JTG CAM AREA CODE 1910 DATE N/A INITIALS N/A REGIONAL ENGINEER ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DATE N/A INITIALS N/A MGR TECH REC & STD DRAWING BY LLO STATION ID DATE 10/16/2020 INITIALS CAM PRINCIPAL ENGINEER CHECKER INITIALS JTG BELLAMY LAKE ROAD DOT RELOCATION (� DUKE r6livaturaliedmont ES&PC DETAILS ENERGY Gas ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA SHEET(S) 14 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION P N G-C-027-0001130 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER seeding mixture species Rate (lb/acre) Rye (grain) 120 Annual lespedeza (Kobe in Piedmont and Coastal Plain, Korean in Mountains) 50 Omit annual lespedeza when duration of temporary cover is not to extend beyond June. seeding dates Mountains —Above 2500 feet: Feb. 15 - May 15 Below 2500 feet: Feb. 1- May 1 Piedmont —Jan. 1 - May 1 Coastal Plain —Dec. 1 - Apr. 15 soil amendments Follow recommendations of soil tests or apply 2,000 lb/acre ground agricultural limestone and 750 lb/acre 10-10-10 fertilizer. mulch Apply 4,000 lb/acre straw. Anchor straw by tacking with asphalt, nettin or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. maintenance Refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. seeding mixture species Rate (lb/acre) German millet 40 In the Piedmont and Mountains, a small -stemmed Sudangrass may be substituted at a rate of 50 lb/acre. seeding dates Mountains —May 15 - Aug. 15 Piedmont —May 1 - Aug. 15 Coastal Plain —Apr. 15 - Aug. 15 soil amendments Follow recommendations of soil tests or apply 2,000 lb/acre ground agricultural limestone and 750 lb/acre 10-10-10 fertilizer. mulch Apply 4,000 lb/acre straw. Anchor straw by tacking with asphalt, nettin , or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. maintenance Refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. seeding mixture species Rate (lb/acre) Rye (grain) 120 seeding dates Mountains —Aug. 15 - Dec. 15 Coastal Plain and Piedmont —Aug. 15 - Dec. 30 soil amendments Follow soil tests or apply 2,000 lb/acre ground agricultural limestone and 1,000 lb/acre 10-10-10 fertilizer. mulch Apply 4,000 lb/acre straw. Anchor straw by tacking with asphalt, nettin , or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. maintenance Repair and refertilize damaged areas immediately. Topdress with 50 lb/acre of nitrogen in March. If it is necessary to extent temporary cover beyond June 15, overseed with 50 lb/acre Kobe (Piedmont and Coastal Plain) or Korean (Mountains) lespedeza in late February or early March. BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP TEMPORARY SEEDING NOTES: 1. COMPLETE GRADING BEFORE PREPARING SEEDBEDS, AND INSTALL ALL NECESSARY EROSION CONTROL PRACTICES SUCH AS, DIKES, WATERWAYS, AND BASINS. MINIMIZE STEEP SLOPES BECAUSE THEY MAKE SEEDBED PREPARATION DIFFICULT AND INCREASE THE EROSION HAZARD. IF SOILS BECOME COMPACTED DURING GRADING, LOOSEN THEM TO A DEPTH OF 6-8 INCHES USING A RIPPER, HARROW, OR CHISEL PLOW. SEEDBED PREPARATION 2. GOOD SEEDBED PREPARATION IS ESSENTIAL TO SUCCESSFUL PLANT ESTABLISHMENT. A GOOD SEEDBED IS WELL -PULVERIZED, LOOSE, AND UNIFORM. WHERE HYDROSEEDING METHODS ARE USED, THE SURFACE MAY BE LEFT WITH A MORE IRREGULAR SURFACE OF LARGE CLODS AND STONES. 3. LIMING —APPLY LIME ACCORDING TO SOIL TEST RECOMMENDATIONS. IF THE PH (ACIDITY) OF THE SOIL IS NOT KNOWN, AN APPLICATION OF GROUND AGRICULTURAL LIMESTONE AT THE RATE OF 1 TO 1 1/2 TONS/ACRE ON COARSE -TEXTURED SOILS AND 2-3 TONS/ACRE ON FINE -TEXTURED SOILS IS USUALLY SUFFICIENT. APPLY LIMESTONE UNIFORMLY AND INCORPORATE INTO THE TOP 4-6 INCHES OF SOIL. SOILS WITH A PH OF 6 OR HIGHER NEED NOT BE LIMED. 4. FERTILIZER —BASE APPLICATION RATES ON SOIL TESTS. WHEN THESE ARE NOT POSSIBLE, APPLY A 10-10-10 GRADE FERTILIZER AT 700-1,000 LB/ACRE. BOTH FERTILIZER AND LIME SHOULD BE INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. IF A HYDRAULIC SEEDER IS USED, DO NOT MIX SEED AND FERTILIZER MORE THAN 30 MINUTES BEFORE APPLICATION. 5. SURFACE ROUGHENING —IF RECENT TILLAGE OPERATIONS HAVE RESULTED IN A LOOSE SURFACE, ADDITIONAL ROUGHENING MAY NOT BE REQUIRED, EXCEPT TO BREAK UP LARGE CLODS. IF RAINFALL CAUSES THE SURFACE TO BECOME SEALED OR CRUSTED, LOOSEN IT JUST PRIOR TO SEEDING BY DISKING, RAKING, HARROWING, OR OTHER SUITABLE METHODS. GROOVE OR FURROW SLOPES STEEPER THAN 3:1 ON THE CONTOUR BEFORE SEEDING (PRACTICE 6.03, SURFACE ROUGHENING). PLANT SELECTION 6. SELECT AN APPROPRIATE SPECIES OR SPECIES MIXTURE FROM TABLE 6.10A FOR SEEDING IN LATE WINTER AND EARLY SPRING, TABLE 6.10B FOR SUMMER, AND TABLE 6.10C FOR FALL. 7. IN THE MOUNTAINS, DECEMBER AND JANUARY SEEDINGS HAVE POOR CHANCES OF SUCCESS. WHEN IT IS NECESSARY TO PLANT AT THESE TIMES, USE RECOMMENDATIONS FOR FALL AND A SECURELY TACKED MULCH. SEEDING 8. EVENLY APPLY SEED USING A CYCLONE SEEDER (BROADCAST), DRILL, CULTIPACKER SEEDER, OR HYDROSEEDER. USE SEEDING RATES GIVEN IN TABLES 6.10A-6.10C. BROADCAST SEEDING AND HYDROSEEDING ARE APPROPRIATE FOR STEEP SLOPES WHERE EQUIPMENT CANNOT BE DRIVEN. HAND BROADCASTING IS NOT RECOMMENDED BECAUSE OF THE DIFFICULTY IN ACHIEVING A UNIFORM DISTRIBUTION. 9. SMALL GRAINS SHOULD BE PLANTED NO MORE THAN 1 INCH DEEP, AND GRASSES AND LEGUMES NO MORE THAN 1/2 INCH. BROADCAST SEED MUST BE COVERED BY RAKING OR CHAIN DRAGGING, AND THEN LIGHTLY FIRMED WITH A ROLLER OR CULTIPACKER. HYDROSEEDED MIXTURES SHOULD INCLUDE A WOOD FIBER (CELLULOSE) MULCH. MULCHING 10. THE USE OF AN APPROPRIATE MULCH WILL HELP ENSURE ESTABLISHMENT UNDER NORMAL CONDITIONS, AND IS ESSENTIAL TO SEEDING SUCCESS UNDER HARSH SITE CONDITIONS (PRACTICE 6.14, MULCHING). HARSH SITE CONDITIONS INCLUDE: • SEEDING IN FALL FOR WINTER COVER (WOOD FIBER MULCHES ARE NOT CONSIDERED ADEQUATE FOR THIS USE), • SLOPES STEEPER THAN 3:1, • EXCESSIVELY HOT OR DRY WEATHER, • ADVERSE SOILS (SHALLOW, ROCKY, OR HIGH IN CLAY OR SAND), AND • AREAS RECEIVING CONCENTRATED FLOW. 11. IF THE AREA TO BE MULCHED IS SUBJECT TO CONCENTRATED WATER FLOW, AS IN CHANNELS, ANCHOR MULCH WITH NETTING (PRACTICE 6.14, MULCHING). TEMPORARY SEEDING MAINTENANCE NOTES: 1. RESEED AND MULCH AREAS WHERE SEEDLING EMERGENCE IS POOR, OR WHERE EROSION OCCURS, AS SOON AS POSSIBLE. DO NOT MOW. PROTECT FROM TRAFFIC AS MUCH AS POSSIBLE. DETAIL SCALE: NTS TEMPORARY SEEDING PERMANENT SEEDING SCHEDULE: THE KINDS OF SEED AND FERTILIZER, AND THE RATES OF APPLICATION OF SEED, FERTILIZER, AND LIMESTONE, SHALL BE AS STATED BELOW. DURING PERIODS OF OVERLAPPING DATES, THE KIND OF SEED TO BE USED SHALL BE DETERMINED. ALL RATES ARE IN POUNDS PER ACRE. MARCH 1 - AUGUST 31 50# TALL FESCUE 10# CENTIPEDE 25# BERMUDAGRASS (HULLED) (UNHULLED) 500# FERTILIZER 4000# LIMESTONE PERMANENT SEEDING NOTES: SEPTEMBER 1 - FEBRUARY 28 50# TALL FESCUE 10# CENTIPEDE 35# BERMUDAGRASS 500# FERTILIZER 4000# LIMESTONE SOIL PREPARATION 1. PROPER SOIL PREPARATION IS NECESSARY FOR SUCCESSFUL SEED GERMINATION AND ROOT ESTABLISHMENT. IT IS ALSO NECESSARY FOR ESTABLISHMENT OF ROOTED SPRIGS, SOD AND WOODY PLANTS. HEAVILY COMPACTED SOILS PREVENT AIR, NUTRIENTS AND MOISTURE FROM REACHING ROOTS THEREBY RETARDING OR PREVENTING PLANT GROWTH. THE SUCCESS OF SITE STABILIZATION AND REDUCTION OF FUTURE MAINTENANCE ARE DEPENDENT ON AN ADEQUATELY PREPARED SOIL BED. FOLLOWING ARE THE REQUIREMENTS FOR PREPARATION OF AREAS TO BE VEGETATED BY GRASSING, SPRIGGING, SODDING, AND/OR PLANTING OF WOODY PLANTS: GENERAL REQUIREMENTS: 2. PREPARATION FOR PRIMARY/PERMANENT STABILIZATION SHALL NOT BEGIN UNTIL ALL CONSTRUCTION AND UTILITY WORK WITHIN THE PREPARATION AREA IS COMPLETE. HOWEVER, IT MAY BE NECESSARY TO PREPARE FOR NURSE CROPS PRIOR TO COMPLETION OF CONSTRUCTION AND INSTALLATION OF UTILITIES. 3. A NORTH CAROLINA DEPARTMENT OF AGRICULTURE SOILS TEST (OR EQUAL) SHALL BE OBTAINED FOR ALL AREAS TO BE SEEDED, SPRIGGED, SODDED OR PLANTED. RECOMMENDED FERTILIZER AND PH ADJUSTING PRODUCTS SHALL BE INCORPORATED INTO THE PREPARED AREAS AND BACKFILL MATERIAL PER THE TEST. 4. ALL AREAS TO BE SEEDED OR PLANTED SHALL BE TILLED OR RIPPED TO A DEPTH SPECIFIED ON THE APPROVED PLANS, CONSTRUCTION SEQUENCE AND/OR CONSTRUCTION BID LIST. RIPPING CONSISTS OF CREATING FISSURES IN A CRISS-CROSS PATTERN OVER THE ENTIRE SURFACE AREA, UTILIZING AN IMPLEMENT THAT WILL NOT GLAZE THE SIDE WALLS OF THE FISSURES. SITE PREPARATION THAT DOES NOT COMPLY WITH THESE DOCUMENTS SHALL NOT BE ACCEPTABLE. THE DEPTH OF SOIL PREPARATION MAY BE ESTABLISHED AS A RANGE BASED ON THE APPROVAL OF THE REVIEWING STATE OR LOCAL AGENCY. ONCE TILLED OR RIPPED ACCORDING TO THE APPROVED PLAN, ALL AREAS ARE TO BE RETURNED TO THE APPROVED FINAL GRADE. PH MODIFIERS AND/OR OTHER SOIL AMENDMENTS SPECIFIED IN THE SOIL TESTS CAN BE ADDED DURING THE SOIL PREPARATION PROCEDURE OR AS DESCRIBED BELOW. 5. ALL STONES LARGER THAN THREE (3) INCHES ON ANY SIDE, STICKS, ROOTS, AND OTHER EXTRANEOUS MATERIALS THAT SURFACE DURING THE BED PREPARATION SHALL BE REMOVED. AREAS TO BE SEEDED: 6. TILL OR DISC THE PREPARED AREAS TO BE SEEDED TO A MINIMUM DEPTH OF FOUR (4) INCHES. REMOVE STONES LARGER THAN THREE (3) INCHES ON ANY SIDE, STICKS, ROOTS AND OTHER EXTRANEOUS MATERIALS THAT SURFACE. IF NOT INCORPORATED DURING THE SOIL PREPARATION PROCESS, ADD PH MODIFIER AND FERTILIZERS AT THE RATE SPECIFIED IN THE SOIL TEST REPORT. 7. RE -COMPACT THE AREA UTILIZING A CULTIPACKER ROLLER. THE FINISHED GRADE SHALL BE A SMOOTH EVEN SOIL SURFACE WITH A LOOSE, UNIFORMLY FINE TEXTURE. ALL RIDGES AND DEPRESSIONS SHALL BE REMOVED AND FILLED TO PROVIDE THE APPROVED SURFACE DRAINAGE. SEEDING OF GRADED AREAS IS TO BE DONE IMMEDIATELY AFTER FINISHED GRADES ARE OBTAINED AND SEEDBED PREPARATION IS COMPLETED. AREAS TO BE SPRIGGED, SODDED, AND/OR PLANTED: 8. AT THE TIME OF PLANTING TILL OR DISC THE PREPARED AREAS TO A DEPTH OF FOUR (4) TO SIX (6) INCHES BELOW THE APPROVED FNISHED GRADE. REMOVE ALL STONES LARGER THAN THREE (3) INCHES ON ANY SIDE, STICKS, ROOTS AND OTHER EXTRANEOUS MATERIALS THAT SURFACE. IF NOT INCORPORATED IN THE RIPPING PROCESS, ADD PH MODIFIER, FERTILIZER, AND OTHER RECOMMENDED SOIL AMENDMENTS. 9. RE -COMPACT THE AREA UTILIZING A CULTIPACKER ROLLER AND PREPARE FINIAL GRADES AS DESCRIBED ABOVE. INSTALL SPRIGS, SOD AND PLANTS AS DIRECTED IMMEDIATELY AFTER FINE GRADING IS COMPLETE. MULCH, MAT AND/OR TACK AS SPECIFIED. DETAIL 2 SCALE: NTS PERMANENT SEEDING , r kit ;lI L'`Ir 1�r• h'y l �t ram'-� aM4PllyM 41,% t ,•,,.` i'}d�u� � tly���Wou,��wrh,uNulilt� y ;`. 11I�JId4tl1, 'ill, uI6 I. �1N1,`IlINl1,!�t..� , !IY : ►�l/lt'1 11` 4y,, Ilk d ,.� pp1Uly',. ill, t,dldr.rl d t � 11! I'I ili `,• IUI/P��r�tls�t�14 �ir � yf1 h,.ry,,t � ��, t't\PII.�il r11 IIr, lr� ±,�",'•�, � llllhll,.1�a11111���Ilk i, 6111.flu,. t W1 M.rf+„� y Y1/It tail Yn. �La.�-.lilh ♦ le r r / !..-I\\t4i��►� '�, ��„1�� ti, 111 ( Iilldlrjlt(f, y ti1iII ow,_ I •r rte r.117 �.11� y Idd� Id�`� )A off, ���^"�aflll.n• yU� PERSPECTIVE VIEW A - a M--a6-.--- -:A— - V:ti]9I111111*751IATA CONSTRUCTION SPECIFICATIONS 1. INSTALL THE DIVERSION AS SOON AS THE RIGHT-OF-WAY HAS BEEN CLEARED AND GRADED. 2. DISK THE BASE FOR THE CONSTRUCTED RIDGE BEFORE PLACING FILL. 3. TRACK THE RIDGE TO COMPACT IT TO THE DESIGN CROSS SECTION. 4. LOCATE THE OUTLET ON AN UNDISTURBED AREA. ADJUST FIELD SPACING OF THE DIVERSION TO USE THE MOST STABLE OUTLET AREAS. WHEN NATURAL AREAS ARE NOT DEEMED SATISFACTORY, PROVIDE OUTLET PROTECTION. 5. IMMEDIATELY SEED AND MULCH THE PORTIONS OF THE DIVERSIONS NOT SUBJECT TO CONSTRUCTION TRAFFIC. STABILIZE WITH GRAVEL AREAS TO BE CROSSED BY VEHICLES. MAINTENANCE PERIODICALLY INSPECT RIGHT-OF-WAY DIVERSIONS FOR WEAR AND AFTER EVERY HEAVY RAINFALL FOR EROSION DAMAGE. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA, AND REPAIR THE DIKE. CHECK OUTLET AREAS, AND MAKE TIMELY REPAIRS AS NEEDED. WHEN PERMANENT ROAD DRAINAGE IS ESTABLISHED AND THE AREA ABOVE THE TEMPORARY RIGHT-OF-WAY DIVERSIONS IS PERMANENTLY STABILIZED, REMOVE THE DIKE, AND FILL THE CHANNEL TO BLEND WITH THE NATURAL GROUND, AND APPROPRIATELY STABILIZE THE DISTURBED AREA. DETAIL 3 SCALE: NTS �� RIGHT-OF-WAY DIVERSION PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO. DATE REVISION(S) DESCRIPTION BY CHK APPD I DESCRIPTION APPROVALS Piedmont DUKE 0111 4 ENERGY, Natural Gas COPYRIGHT 2018 BELLAMY LAKE ROAD DOT RELOCATION ES&PC DETAILS E N F I E L D, NORTH CAROLINA TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA A 10-16-2020 ISSUED FOR 90% REVIEW LLO JTG CAM AREA CODE 1910 DATE N/A INITIALS N/A REGIONAL ENGINEER ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DATE N/A INITIALS N/A MGR TECH REC & STD DRAWING BY LLO STATION ID DATE 10/16/2020 INITIALS CAM PRINCIPAL ENGINEER CHECKER INITIALS JTG SHEET(S) 15 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISION P N G-C-027-0001 1 31 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER MACHINE CLEARING ONLY AREA BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A. McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP \A/ATTI =1 T!l MAINTENANCE NOTES: 1. REMOVE AND DISPOSE OF SILT ACCUMULATIONS WHEN THE DEPTH REACHES ONE-HALF OF THE HEIGHT OF THE PERIMETER WATTLES. 2. REPLACE OR CLEAN THE WATTLES AS NEEDED TO ALLOW RUNOFF TO SLOWLY DEWATER THROUGH THE DEVICE BETWEEN RAIN EVENTS. 3. MONITOR THE WOODEN STAKES AND STAPLES TO ENSURE THAT THE WATTLES REMAIN SECURELY ANCHORED AFTER RAIN EVENTS. 4. MONITOR DAILY TO SUPPLEMENT / REFURBISH / REPLACE MATS TO ENSURE PROPER FUNCTIONALITY. 5. CLEAN ANY ERODIBLE MATERIAL OR POLLUTANT TRACKED ONTO THE MATS IMMEDIATELY. 6. TIMBER MATS AND ALL OTHER MATERIALS SHALL BE COMPLETELY REMOVED DURING FINAL CLEAN-UP. REMOVAL OF THIS STRUCTURE IS NOT CONTINGENT UPON ESTABLISHMENT OF PERMANENT VEGETATION. 7. ATTEMPT TO USE NO MORE THAN TWO (2) LAYERS OF TIMBER MATS IN WETLANDS. 8. TIMBER MATS SHALL EXTEND A MINIMUM OF 15 FEET OUTSIDE OF WETLAND BOUNDARIES. 9. INSTALL EARTHEN RAMP APPROACHES TO TIMBER MATS. EARTHEN RAMPS TO BE CONSTRUCTED OF UPLAND MATERIAL. TOP SOIL SHALL NOT BE USED. 10. INSTALL TIMBER MATS IN WORK AREA AS NEEDED. POSITION A SERIES OF TIMBER MATS AS NEEDED TO CREATE A SAFE, FLAT, WORK AREA. MATS SHALL BE POSITIONED TO BUTT UP AGAINST EACH OTHER AND INTERLOCK OR ATTACH TO EACH OTHER. 11. EROSION CONTROL DEVICES SHALL BE INSTALLED ADJACENT TO TIMBER MATS AS SHOWN ON THE PLAN DRAWINGS. 12. CONTRACTOR SHALL PREVENT THE INTRODUCTION OF UPLAND SOILS OR OTHER MATERIALS INTO WETLANDS. V VJ1 I I LL%7 I V I-%UU I I IIVI ULR IVI/_% I J. USE 1 FOOT OVERLAP ON ADJOINING WATTES DETAIL SCALE: NTS TIMBER MATS 209 - 0" DISTURBED AREA FOR ACCESS ROAD 2" EXISTING GRADE INSTALLATION NOTES: CLEARING AND GRUBBING AREA 1/4" INCH PER FOOT (2%) SIDE SLOPE (TYPICAL) 169 - 0" PERMANENT ACCESS ROAD ITL COMPACTED SOIL FILTRATION GEOTEXTILE TO STABILIZE FOUNDATION (ESPECIALLY IMPORTANT WHERE SOFT SOIL IS ANTICIPATED) USE 4" OF COMPACTED ABC STONE. TOP COURSE 2-3" #57 STONE. MAINTENANCE NOTES: MONITOR TO SUPPLEMENT STONE OR BLADE TO MAINTAIN UNIFORM RIDING SURFACE DETAIL 2 SCALE: NTS PERMANENT ACCESS ROAD MACHINE CLEARING ONLY AREA PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO INSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSER ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY I CHK JAPPD DESCRIPTION LLO I JTG ICAM AREA CODE ACCOUNT NUMBER PROJECT NUMBER DRAWING BY STATION ID CHECKER INITIALS 1910 10700 MX5694600 LLO JTG APPROVALS DATE INITIALS REGIONAL B E L LA M Y LAKE ROAD DOT RELOCATION N/A NIA ENGINEER DATE INITIALS MGR TECH DUKE 0111. Pieddo t ES&PC DETAILS N/AATE NIA REC&STDENFIELD, NORTH CAROLINA DATE INITIALS 10/16/2020 CAM PRINCIPAL ENGINEER COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA SHEET(S) 16 OF 20 1 DWG SCALE AS NOTED DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER P N G-C-027-0001132 DISCIPLINE / RESOURCE CENTER / LINE NUMBER REVISION A BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A. McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP SEE NOTE 1 r- GRADE /\ > XI/ o �� SLURRY OR NATIVE BACKFILL 95% c? RELATIVE COMPACTION N SEE NOTE 3 z LU o � U I z 1 2 6" WIDE POLYETHYLENE "BURIED NATURAL GAS PIPELINE" WARNING TAPE BACKFILL WITH SIFTED (ROCK AND DEBRIS FREE) NATIVE BACKFILL OR SAND SLURRY 2.00' ABOVE PIPE 8" OD MDPE, FOR FULL SPECIFICATION SEE BILL OF MATERIALS TRACER WIRE #14 GAUGE SEE NOTE 2 12" MIN. NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR BACKFILL AND RESTORATION WORK OF ALL ROADS (PAVED AND UNPAVED) AS REQUIRED BY PIEDMONT NATURAL GAS AND GOVERNING AGENCIES. ABOVE GRADE PIPELINE MARKER UNPAVED SURFACE NOTES: 1. PIPELINE MARKERS SHALL BE PLACED AT: I7A\ /CRACAIT - IN LINE -OF -SIGHT INTERVALS AND TURNING POINTS - ALL PUBLIC ROAD CROSSINGS - ALL RAILROAD CROSSINGS - RIVER, STREAM, CREEK, DITCH AND CANAL CROSSINGS - UTILITY CROSSINGS (PER DUKE DISCRETION) - SWAMPS OR WETLANDS (ENTRY AND EXIT) - ROAD MEDIANS - ABOVE GROUND FACILITIES SUCH AS VALVE SETTINGS, BORDER STATIONS, REGULATOR STATIONS, AND PIPELINE INTERCONNECTS - UNDERGROUND VALVES - HDD ENTRY AND EXIT POINTS 2. PIPELINE MARKERS SHALL BE PLACES DIRECTLY ON TOP OR WITHIN 24 INCHES OF THE PIPELINE. 3. SET MARKERS AS SOON AS PRACTICAL AFTER THE INSTALLATION OF THE PIPELINE. MAKE EVERY EFFORT TO PROVIDE MARKERS BEFORE VEGETATION IS RE-ESTABLISHED AFTER CONSTRUCTION. 2. TRACER WIRE SHALL BE INSTALLED UNDER PLASTIC PIPE, WITH BACKFILL BETWEEN TRACER WIRE AND PIPE WITH NO CONTACT DIRECT BETWEEN THEM. TRACER WIRE 4. ABOVE GRADE PIPELINE MARKERS TO BE INSTALLED IN GRASS OR UNPAVED AREAS WHEN MAY NOT BE WRAPPED AROUND A MAIN OR SERVICE LINE. PIPELINE MARKER IS REQUIRED. 3. THE TOP LAYER OF BACKFILL SHALL NOT CONTAIN ANY ROCKS WITH A DIAMETER 5. FLUSH PIPELINE MARKERS TO BE INSTALLED IN PAVEMENT WHEN PIPELINE MARKER IS REQUIRED. LARGER THAN 3 INCHES. DETAIL SCALE: NTS TYPICAL TRENCH BACKFILL PROFILE DETAIL 2 SCALE: NTS ABOVE GRADE AND FLUSH PIPELINE MARKER *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS I ARR APPROVALS DATE INITIALS N/A NIA REGIONAL ENGINEER DATE INITIALS MGR TECH N/A NIA REC & STD DATE INITIALS PRINCIPAL 10/16/2020 CAM ENGINEER FLUSH PIPELINE MARKER BELLAMY LAKE ROAD DOT RELOCATION V Ar DUKE N RGYy r6111 Pied ont CONSTRUCTION DETAILS ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW SHEET(S) 17 OF 20 1 DWG SCALE NOT TO SCALE DWG DATE 10/16/2090 1 SUPERSEDED DRAWING NUMBER REVISIO P N G-C-027-0001135 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER NOTES: SEE NOTE 5 TYPICAL CROSS SECTION FOREIGN PIPELINE R.O.W. w z O � w z w _ -- � O I PROPOSED PIPELINE BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A. McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP 2'-0" MIN. (NOTE 5) NO VERT. OR HORZ. BENDS WITHIN R.O.W. CROSS SECTION OF FOREIGN P/L R.O.W. 1. PIPELINE MARKER TO BE INSTALLED AS SPECIFIED ON ALIGNMENT SHEETS. 2. INSTALL PIPELINE MARKER ON ROW LINE NEXT TO FENCE IF POSSIBLE. 3. SEE ALIGNMENT PLAN AND PROFILE DRAWINGS FOR MATERIAL SPECIFICATION. 4. CROSSING TO BE AS NEAR TO 900 TO THE CENTERLINE OF ROADWAY AS PRACTICAL. 5. EXCAVATION WITHIN THE LIMITS OF THE ROAD EASEMENT SHALL BE REPLACED WITH BACKFILL SPECIFIED BY THE ENGINEER AND COMPACTED IN 6-INCH LAYERS. DETAIL 3 SCALE: NTS CONCEPT OPEN CUT - ROAD CROSSING TYPICAL TEST LEAD STN. NOTE 3 EXISTING GRADE REFERENCE CELL (NOTE 3) EXISTING FOREIGN P/L NOTES: 1. FOREIGN PIPELINE LOCATIONS & DEPTHS TO BE DETERMINED BY ELECTRONIC MEANS IN ADVANCE OF PIPELINE CONSTRUCTION AND CONFIRMED BY CAREFULLY EXPOSING BY HAND DIGGING. WHERE WITHIN 24" IN ANY DIRECTION FROM THE PIPELINE. 2. OWNER OF FOREIGN PIPELINE(S) SHALL BE NOTIFIED 48 HOURS IN ADVANCE OF EXCAVATION OF CROSSING. 3. DEPTH OF PIPELINE INCLUDING 2'-0" MIN. CLEARANCE SHALL BE MAINTAINED FOR ALL FULL BURIED CABLE R.O.W. (IF EXISTS) ANGULAR WIDTH OF FOREIGN PIPELINE R.O.W. = CO 4. PROPOSED PIPELINE MAY ONLY CROSS ABOVE THE FOREIGN PIPELINE(S) WHERE REQUESTED _ z BY OR APPROVED BY FOREIGN OWNER IN WRITING. DETAIL 5 SCALE: NTS CROSSING FOREIGN PIPELINE ROPING BENDS PROPOSED PIPELINE w o EXISTING z BURIED CABLE 2'-0' MIN. (NOTE 7) NO VERT. OR HORZ. BENDS WITHIN R.O.W. EXISTING GRADE ROPING BENDS SANDBAG SUPPORT TO PREVENT DAMAGE DURING BACKFILL DETAIL 6 SCALE: NTS NOTES: 1. BURIED CABLE LOCATIONS & PIPE DEPTHS TO BE DETERMINED BY ELECTRONIC MEANS IN ADVANCE OF PIPELINE CONSTRUCTION AND CONFIRMED BY CAREFULLY EXPOSING BY HAND DIGGING. WHEN WITHIN 24" IN ANY DIRECTION FROM THE PIPELINE. 2. OWNER OF BURIED CABLE(S) SHALL BE NOTIFIED 48 HOURS IN ADVANCE OF EXCAVATION OF CROSSING. 3. DEPTH OF PIPELINE INCLUDING 2'-0" MIN. CLEARANCE SHALL BE MAINTAINED FOR THE FULL ANGULAR WIDTH OF BURIED CABLE R.O.W. 4. PROPOSED PIPELINE MAY ONLY CROSS ABOVE BURIED CABLE(S) WHERE APPROVED IN WRITING BY BURIED CABLE OWNER. 5. CONTRACTOR TO SUPPORT EXPOSED CABLE WITH WOOD PLANK OR STRUCTURAL STEEL DURING CONSTRUCTION. 6. CONTRACTOR TO UTILIZE CAUTION WITH PLACEMENT OF BACKFILL TO MINIMIZE POSSIBLE DAMAGE TO THE CABLE. 7. REFER TO 0&M 204 / C1005. CONSTRUCTION NEAR COMPANY FACILITIES. CROSS SECTION OF BURIED CABLE R.O.W. *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK I APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS ARR DATE N/A DATE N/A DATE 10/16/2020 INITIALS NIA INITIALS NIA INITIALS CAM APPROVALS REGIONAL ENGINEER 4nDUKE ENERGY., MGR TECH REC & STD PRINCIPAL ENGINEER 011 Piedmont Natural Gas COPYRIGHT 2018 BELLAMY LAKE ROAD DOT RELOCATION CONSTRUCTION DETAILS ENFI ELD, NORTH CAROLINA TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW SHEET(S) 18 OF 20 DWG SCALE NOT TO SCALE DWG DATE 10/16/2090 SUPERSEDED DRAWING NUMBER REVISION P N G-C-027-0001136 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER ;ETC 7606 Whitehall Executive Center Drive Charlotte, NC 28273 704-529-3200 Fax 704-529-3272 TEST BORING LOG 7606 Whitehall Executive Center Drive Charlotte, NC 28273 704-529-3200 Fax 704-529-3272 TEST BORING LOG jAFk 7606 Whitehall Executive Center Drive TEST BORING LOG 'ffICCharlotte, NC 28273 A IF704-529-3200 Fax 704-529-3272 BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A MCMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP CLIENT BURNS & MCDONNELL BORING # B-1 PROJECT NAME PNG JOB # 199BAM2006 PROJECT LOCATION Bellamy Lake Road DRAWN BY JIGS Enfield, NC APPROVED BY JIGS Date Started 5/6120 Hammer Wt. 140 lbs. Date Completed 5/6120 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Core Dia. NIA in. N Boring Method HSA Shelby Tube OD NIA in. �L °Q -9 r- E m d O. (' «. d in i av 0 s~ En i VO 7 m O d o m C SOIL CLASSIFICATION d z T a E 3 L L° m L m a) `� m D_ an d m d O. Q m m 8° Q qm E y�. o '6 U m N o a1 SURFACE ELEVATION in ❑ o cn cn z m rn C7 ai rn 1- 6 d :2 a a 6"ORGANIC LADEN SOIL 0.5 1 SS 6 12.0 Loose brown and orange clayey SAND w/ trace rock 2.0 2 fragments f SS 4 18.3 Very loose brown and orange silty SAND w/ trace 4.0 clay SS 2 .2 3 Very soft to soft light brown and tan sandy SILT 5 4 SS 3 20 17 52% Passing No. 8.0 SS 5 19.6 200 Sieve Loose brown clayey silty SAND 5 10 13.0 SS 5 26 18 61 % Passing No. Firm brown silty sandy CLAY 6 200 Sieve 15 Y 18.0 SS 64 12.4 PARTIALLY WEATHERED ROCK: Samples as 7 brown silty sand with rock fragments 20 21.5 OR Foliated to massive granitic rock, megacrystic to 8 equigranular. The Geologic Map of NC lists this as an intrusive rock (Le. igneous) but it is lightly metamorphosed, somewhere between a granite and 25.0 a gneiss. 25 ORE 18956 9 REC = 100%, RQD = 84.5% REC = 100%, RQD = 100% 30.0 30 DORE REC = 100%, RQD = 100% 10 35.0 CLIENT BURNS & MCDONNELL BORING # B-1 PROJECT NAME PNG JOB # 199BAM2006 PROJECT LOCATION Bellamy Lake Road DRAWN BY JIGS Enfield, NC APPROVED BY JIGS UMLLIIYV G11U J"Vlr L11YV I1YrVR1Y11111V11 I G0I Uf 1P Date Started 5/6120 Hammer Wt. 140 lbs. Date Completed 5/6120 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Core Dia. NIA in. w tlJ Boring Method HSA Shelby Tube OD N/A in. 8.2 °Q -9 E o a O. (7 din c .m.. a0 wEn c V 7 m O d o C SOIL CLASSIFICATION d 1 2 Z a E 3 L L° m L m o o m O. an d W a1 CL d � m m u° j "O N Q E o :O Q 2 m N o a1 m (continued) in ❑ o co cn z cn U3 C7 m F C7 c� � a a REC = 100%, RQD = 100°% 11 DORE 23840 40.0 40 OR REC = 100%, RQD = 100% 12 45.0 45 DORE REC = 100%, RQD = 96.7% 13 50.0 50 OR REC =100%, RQD = 93.3% 14 55.0 55 'ORE 16109 REC =100%, RQD = 100% 15 60.0 60 OR REC = 95.4%, RQD = 95.4% 16 65.0 65 OR REC = 95.4%, RQD = 92.5% 17 70.0 CLIENT BURNS & MCDONNELL BORING # B-1 PROJECT NAME PNG JOB # 199BAM2006 PROJECT LOCATION Bellamy Lake Road DRAWN BY JIGS Enfield, NC APPROVED BY JIGS n Pii 1 IAIL3 -i CA6API 11Jr, 11UFr1RAAAT10ki TFCT nATA Date Started 5/6120 Hammer Wt. 140 lbs. Date Completed 5/6120 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Core Dia. NIA in. c Z N Boring Method HSA Shelby Tube OD NIA in. L m -9 -EmT o c wm c m v a o CLASSIFICATION E t m c m CL an dmao°3 m _o m zSOIL v N a E oc ar am o m (continued) cna ow cn m � � _1 a ao � REC = 100%, RQD = 100% 18 DORE 75.0 75 BORING TERMINATED Sample Type Depth to Groundwater Boring Method Sample Type Depth to Groundwater Boring Method Sample Type Depth to Groundwater Boring Method SS - Driven Split Spoon a Noted on Drilling Tools WA ft. HSA - Hollow Stem Augers SS - Driven Split Spoon a Noted on Drilling Tools WA ft. HSA - Hollow Stem Augers SS -Driven Split Spoon a Noted on Drilling Tools N/A ft. HSA - Hollow Stem Augers ST -Pressed Shelby Tube * At Completion (in augers) N/A ft. CFA -Continuous Flight Augers ST -Pressed Shelby Tube * At Completion (in augers) N/A ft. CFA -Continuous Flight Augers ST -pressed Shelby Tube S At Completion (in augers) N/A ft. CFA -Continuous Flight Augers CA - Continuous Flight Auger At Completion (open hole) NIA ft. DC - Driving Casing CA - Continuous Flight Auger 9 At Completion (open hole) NIA ft. DC - Driving Casing CA - Continuous Flight Auger 9 At Completion (open hole) NIA ft. DC - Driving Casing RC -Rock Core 3 After NIA hours N/A ft. MD -Mud Drilling RC -Rock Core After NIA hours NIA ft. MD -Mud Drilling RC -Rock Core After N/A hours N/A ft. MD -Mud Drilling CU - Cuttings CU - Cuttings -z CU - Cuttings _z CT - Continuous Tube 7 After NIA hours NIA ft. Page 1 of 3 CT - Continuous Tube y After NIA hours N/A ft. Page 2 of 3 CT - Continuous Tube i After NIA hours N/A ft. Page 3 of 3 1W Cave Depth 17.0 ft. a Cave Depth 17.0 ft. 1W Cave Depth 17.0 ft. 7606 Whitehall Executive Center Drive TEST BORING LOG E- 7606 Whitehall Executive Center Drive TEST BORING LOG r 7606 Whitehall Executive Center Drive TEST BORING LOG kJ Charlotte, NC 28273 / Charlotte, NC 28273 / Charlotte, NC 28273 704-529-3200 704-529-3200 / 704-529-3200 Fax 704-529-3272 Fax 704-529-3272 Fax 704-529-3272 CLIENT BURNS & MCDONNELL BORING # B-2 CLIENT BURNS & MCDONNELL BORING # B-2 CLIENT BURNS & MCDONNELL BORING # B-2 PROJECT NAME PNG JOB # 199BAM2006 PROJECT NAME PNG JOB # 199BAM2006 PROJECT NAME PNG JOB # 199BAM2006 PROJECT LOCATION Bellamy Lake Road DRAWN BY JIGS PROJECT LOCATION Bellamy Lake Road DRAWN BY JIGS PROJECT LOCATION Bellamy Lake Road DRAWN BY JIGS Enfield, NC APPROVED BY JIGS Enfield, NC APPROVED BY JIGS Enfield, NC APPROVED BY JIGS DRILLING and SAMPLING INFORMATION TEST DATA DRILLING and SAMPLING INFORMATION TEST DATA DRILLING and SAMPLING INFORMATION TEST DATA Date Started 514120 Hammer Wt. 140 lbs. Date Completed 514/20 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Core Dia. N/A in. � _ - Boring Method HSA Shelby Tube OD N/A in. 0 °o m m w? m tL m aE n ��... y �Q n ao win cal �> u c o Um a Q c SOIL CLASSIFICATION E ry r m m a d ra a Ho m a 3 m z v- d n s 3 � a '� J a Y Y m SURFACE ELEVATION `� u m 40 m o ra m °"i E C7 2 m o 6 d o m $ m in o o con cn z v> cn N F 2 a a Ir ' 6 " ORGANIC LADEN SOIL 0.5 2.0 1 SS SS 4 7 18.3 17.3 Soft dark orange sandy CLAY Loose dark orange clayey SAND 2 5 SS 9 4219 3 6.0 SS 11 3.6 Stiff dark orange clayey SAND w/ trace silt 4 8.0 SS 59 11.0 PARTIALLY WEATHERED ROCK: Samples as 5 brown silty clayey sand with rock fragments 10 13.0 SS 13 21.4 Stiff brown and orange sandy SILT wl rock fragments 6 15 18.0 SS 8 Firm brown, orange and dark gray sandy SILT w/ 7 rock fragments 20 23.0 SS 42 Dense dark gray and brown silty SAND w/ rock 8 fragments 25 28.0 SS 36 Hard dark gray, orange and brown sandy SILT 9 30 SS 50/4' 10 Date Started 514120 Hammer Wt. 140 lbs. Date Completed 514/20 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Gore Dia. NIA in. � _ - Boring Method HSA Shelby Tube OD NIA in.'15 w? m LL maE n @�.., y ��gg y3 ao wtn cal g> N c o m? _ J a. d Q d c SOIL CLASSIFICATION E w L m am m a E d m a 8 0 E Ea a 3 m z v- c y d n s E 3 a � w a Y Y m E (continued) E a o o N w V) inW e L) 2 L a m z° co I— a a. 36.0 DORE Foliated to massive granitic rock, megacrystic to 11 equigranular. The Geologic Map of NC lists this as an intrusive rock (i.e. igneous) but it is lightly metamorphosed, somewhere between a granite and a gneiss. 40 42.3 DORE REC = 80%, RQD = 64% 12 45 48.5 OR REC = 100%, RQD = 100% 13 50 53.5 DORE REC = 100%, RQD = 90.0% 14 55 58.5 DORE REC = 98.3%, RQD = 92.5% 15 60 63.5 DORE REC = 95%, RQD = 94.2% 16 65 68.5 DOR REC = 100%, RQD = 79.7% 17 Date Started 514/20 Hammer Wt. 140 lbs. Date Completed 5/4120 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Core Dia. NIA in. � t _ - Boring Method HSA Shelby Tube OD NIA in. rn 0 m LL ii =3v N� IL wfn 8 oLO�cc3 J d SOIL CLASSIFICATION o m B j aY E r t� a o°o(continued) c E in znr a a E E p c Z y m P ' n QE 0$ V 0 a Cr a a E Ofm 75.0 75 BORING TERMINATED Sample Type Depth to Groundwater Boring Method Sample Type Depth to Groundwater Boring Method Sample Type Depth to Groundwater Boring Method SS -Driven Split Spoon 0 Noted on Drilling Tools N/A ft. HSA - Hollow Stem Augers SS -Driven Split Spoon 0 Noted on Drilling Tools N/A ft. HSA - Hollow Stem Augers SS -Driven Split Spoon # Noted on Drilling Tools NIA ft. HSA - Hollow Stem Augers ST -Pressed Shelby Tube f At Completion (in augers) NIA ft. CFA - Continuous Flight Augers ST -Pressed Shelby Tube f At Completion (in augers) N/A ft. CFA - Continuous Flight Augers ST -Pressed Shelby Tube f At Completion (in augers) N/A ft. CFA - Continuous Flight Augers CA - Continuous Flight Auger At Completion (open hole) N/A ft. DC - Driving Casing CA - Continuous Flight Auger E� At Completion (open hole) N/A ft. DC - Driving Casing CA - Continuous Flight Auger At Completion (open holed ft. DC - Driving Casing RC - Rock Core CU - Cuttings 3 After NIA hours N/A ft. MD -Mud Drilling RC - Rock Core CU - Cuttings 3 After NIA hours N/A ft. MD -Mud Drilling RC -Rock Core CU - Cuttings 3 After NIA hours NIA ft. MD -Mud Drilling CT - Continuous Tube y After N/A hours N/A ft. Page 1 of 3 CT - Continuous Tube T After NIA hours N/A ft. Page 2 of 3 CT - Continuous Tube y After N/A hours N/A ft. Page 3 of 3 PRELIMINARY - NOT ig Cave Depth 14.0 ft. m Cave Depth 14.0 ft. Cave Depth 14.0 ft. FOR CONSTRUCTION ISSUED FOR 90% REVIEW *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK I APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS ARR APPROVALS DATE INITIALS N/A N/A REGIONAL ENGINEER DATE INITIALS MGR TECH N/A NIA REC & STD DATE INITIALS PRINCIPAL 10/16/2020 CAM ENGINEER BELLAMY LAKE ROAD DOT RELOCATION VDUKE N RGY. r6111 Nad aont GEOTECHNICAL BORING LOGS ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA SHEET(S) 19 OF 20 1 DWG SCALE NOT TO SCALE DWG DATE 10/16/2020 1 SUPERSEDED DRAWING NUMBER REVISIO PNG-C-027-0001140 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER BURNS & McDONNELL CONSULTANTS, INC. STATE LICENSE # C-1435 CLAUDE A McMULLAN IFC SUBMITTAL DATE NORTH CAROLINA SEAL 047852 PROFESSIONAL ENG/ARCH STAMP - 7606 Whitehall Executive Center Drive TEST BORING LOG / 7606 Whitehall Executive Center Drive TEST BORING LOG 1606 Whitehall Executive Center Drive TEST BORING LOG Charlotte, NC 28273 jAk Charlotte, NC 28273 / Charlotte,C V 28273 704-529-3200 704-529-3200 Fax 704-529-3272 Fax 704-529-3272 Fax 704-529-3272 CLIENT BURNS & MCDONNELL BORING # B-3 CLIENT BURNS & MCDONNELL BORING # B-3 CLIENT BURNS & MCDONNELL BORING # B-3 199BAM2006 199BAM2006 199BAM2006 PROJECT NAME PNG JOB # PROJECT NAME PNG JOB # PROJECT NAME PNG JOB # BY JIGS BY JIGS BY JIGS PROJECT LOCATION Bellamy Lake Road DRAWN PROJECT LOCATION Bellamy Lake Road DRAWN PROJECT LOCATION Bellamy Lake Road DRAWN JIGS JIGS JIGS Enfield, NC APPROVED BY Enfield, NC APPROVED BY Enfield, NC APPROVED BY TEST DATA TEST DATA TEST DATA DRILLING and SAMPLING INFORMATION DRILLING and SAMPLING INFORMATION DRILLING and SAMPLING INFORMATION Date Started 5/5120 Hammer Wt. 140 lbs. Date Started 5/5120 Hammer Wt. 140 lbs. Date Started 515120 Hammer Wt. 140 lbs. Date Completed 5/5120 Hammer Drop 30 in. Date Completed 5/5120 Hammer Drop 30 in. Date Completed 515120 Hammer Drop 30 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Drill Foreman FISHBURNE Spoon Sampler OD 2 in. Inspector ATC Rock Core Dia. NIA in. Boring Method HSA Shelby Tube OD N/A in. co 82 m �'� a U. U m N dm d a� 3� E E 8 o r16n rntr C7 c -2-6 -6 m N c 3 ao �p Z c n in r C r w N c m �> c y Q -� 6 ° E ci U e m c o U .-Ti- J d_ E J � � a U m a m O °' a N cYi a m m E Inspector ATC Rode Core Dia. NIA in. Boring Method HSA Shelby Tube OD NIA in. N 8 2 L= m D m a ``U U N dm D_ O. > E E 8 m m m m m� c D a+ — o m N c 3 °.�' ao m ,p 3� Z o c m U in r C 8i P w CO c m $> c y Q .m 6 °' E Ci U o tm„ c o U +�. J d_ E J � J a E Z] U y a m O m a N cYi ao m m E Inspector ATC Rock Core Dia. N/A in. Boring Method HSA Shelby Tube OD N/A in. N 2 :E m n a mU U m dm d d> E E 8 `m° ca "' m j o c 2 .6 — °Q N N c a ao o o m 'O Z c w m in r Z C -9 d .9 m $> c y Z N m i]. a E o d U c m o U ate+ N o 2 _ J d J O 5 v a U 5 m a m m 2 m a- N o a m m E m SOIL CLASSIFICATION E a s cn o n m N d E m z SOIL CLASSIFICATION E _3 L a ° m cn� yL-. m o m m o U m N d E an d mz SOIL CLASSIFICATION E � r n Co0 t... m a 0� N O. E CoWiz6 SURFACE ELEVATION {continued) (continued)7 6 "ORGANIC LADEN SOIL 0.5 1 SS 5 17.4 REC = 100%, RQD = 100% 11 O REC = iD0%, RQD = 100% 18 OR Loose light brown silty SAND 2.0 Very stiff orangish brown sandy CLAY 2 SS 20 33 17 4.0 Very stiff dark orangish brown, brown, and white sandy CLAY 3 6.0 5 SS 23 23.3 40.0 40 ORE 75.0 75 0996 REC = 100%, RQD = 95% 12 BORING TERMINATED Medium dense dark orangish brown, brown, and 4 SS white clayey SAND 8.0 Medium dense dark orange clayey SAND 5 SS 15 15.3 10 45.0 45 'ORE 21924 REC = 100%, RQD = 100% 13 13.0 Very dense dark gray silty SAND w/ rock fragments 6 SS 50/1" 15 50.0 50 30RE 22993 REC = 100%, RQD = 100% 14 SS 5011" 7 21.0 20 55.0 55 OR REC = 100%, RQD = 100% 15 Foliated to massive granitic rock, megacrystic to 8'ORE equigranular. The Geologic Map of NC lists this as an intrusive rock (i.e. igneous) but it is lightly metamorphosed, somewhere between a granite and a gneiss. REC = 100%, RQD = 100% 25.0 25 ',ORE 60.0 60 ORE 14749 9 REC = 100%, RQD = 94.2% 16 REC = 100%, RQD = 100% 30.0 30 ORE 65.0 65 OR REC = 100%, RQD = 94.6% 10 REC = 91.7%, ROD = 78.3% 17 35.0 70.0 Sample Type Depth to Groundwater Boring Method Sample Type Depth to Groundwater Boring Method Sample Type Depth to Groundwater Boring Method SS - Driven Split Spoon A Noted on Drilling Tools NIA ft. HSA - Hollow Stem Augers SS -Driven Split Spoon A Noted on Drilling Tools NIA ft. HSA - Hollow Stem Augers SS - Driven Split Spoon ! Noted on Drilling Tools N/A ft. HSA - Hollow Stem Augers ST - Pressed Shelby Tube At Completion (in augers) CA - Continuous Flight Auger RC - Rock Core At Completion (open CU -Cuttings � After NIA hours CT -Continuous Tube After NIA hours 1a Cave Depth N/A hole) N/A N/A N/A 16.0 ft. ft. ft. ft. ft. CFA DC MD - Continuous Flight Augers - Driving Casing - Mud Drilling Page 1 of 3 ST - Pressed Shelby Tube At Completion (in augers) CA - Continuous Flight Auger RC - Rock Core At Completion (open CU -Cuttings 3 After N/A hours CT -Continuous Tube After NIA hours a Cave Depth N/A hole) N/A NIA N/A 16.0 ft. ft. ft. ft. ft. CFA DC MD - Continuous Flight Augers - Driving Casing -Mud Drilling Page 2 of 3 ST - Pressed Shelby Tube At Completion (in augers) CA - Continuous Flight Auger At Completion (open RC - Rock Core CU -Cuttings After NIA hours CT - Continuous Tube After N/A hours Cave Depth N/A hole) N/A N/A 16.0 ft. ft. ft. ft. ft. CFA DC MD -Continuous Flight Augers - Driving Casing -Mud Drilling Page 3 of 3 *PROPRIETARY & CONFIDENTIAL *ALL RIGHTS RESERVED *DO NOT SCALE THIS DRAWING *USE DIMENSIONS ONLY DUKE ENERGY & PIEDMONT NATURAL GAS DRAWINGS ARE CONFIDENTIAL *DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE *TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE, ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO MANAGEMENT (RIM) NO.1 DATE I REVISION(S) DESCRIPTION A 110-16-20201 ISSUED FOR 90% REVIEW BY CHK I APPD DESCRIPTION MJD ARR CAM AREA CODE 1910 ACCOUNT NUMBER 10700 PROJECT NUMBER MX5694600 DRAWING BY MJD STATION ID CHECKER INITIALS ARR APPROVALS DATE INITIALS N/A N/A REGIONAL ENGINEER DATE INITIALS MGR TECH N/A NIA REC & STD DATE INITIALS PRINCIPAL 10/16/2020 CAM ENGINEER BELLAMY LAKE ROAD DOT RELOCATION DUN E 011INatural Piedmont GEOTECHNICAL BORING LOGS ENFI ELD, NORTH CAROLINA COPYRIGHT 2018 TARBORO RESOURCE CENTER, TARBORO, NORTH CAROLINA PRELIMINARY - NOT FOR CONSTRUCTION ISSUED FOR 90% REVIEW SHEET(S) 20 OF 20 DWG SCALE NOT TO SCALE DWG DATE 10/16/2020 SUPERSEDED DRAWING NUMBER REVISIO PNG-C-027-0001141 A DISCIPLINE / RESOURCE CENTER / LINE NUMBER