Loading...
HomeMy WebLinkAboutNC0025534_FTSE_2001_Historic_20210114PATTERSON & PAYURSON PAUL PATTERSON WILLIAM PATTER ON PROFESSIONAL ENGQJEERlLAND SURVEYOR PROFESSIONAL LAND SURVEYOR P.O. BOX 1189 HENDERSONVILLE, NC28793-1189 1-828-692-6629 (TEL & FAX) MEMORANDUM December 21, 2006 Roger C. Edwards Surface Water Protection Supervisor Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 2a73-9— Project: KINAL COMPLETION CERTIFICATION Gann Village City of Hendersonville - Henderson County P&P Job No.: 04-12-86-ENG NCDENR Permit No. WQ0019927 Dated - May 18, 2001 Dear Sir/Madam: rr rF' :, - F 2007 D ---- �3CTION • _ OFFICE --y Please find attached herewith, a Final Completion Certification for the Wastewater Collection System Extension to provide sewer service to Gann Village, with the installation of approximately 498 linear feet (total) of eight (8) inch diameter sewer line with three (3) manholes (i.e., starting from sewer manhole MH#10 to sewer manhole MH#13. Furthermore, the new asbuilt drawing has been attached for your records. Please note that the asbuilt provided is for the entire Gann Village project to the original tie-in at Britton Creek. I am hereby requesting final approval of this project from your office. Should you have any questions or comments, please feel free to call. Thanks in advance for your cooperation in this matter. Sincerely, 62�9;t� Paul Patterson, P.E. cc: File: 06-11-72-Eng Dennis Frady, Assistant Utilities Director @ City of Hendersonville Water & Sewer Department c:\lotus\work\wordpro\wsspecs`certs\gannslt2.lwp ENGINEERING - SURVEYING - PLANNING o. WQ0019927 May 18, 2001 ENGINEERS CERTIFICATION Partial t/ Final 1, ( T4w�so^ , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Gann Village Hendersonville, NC Henderson County for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date 4( 5E6 4pDI'no-JAL C4RVnFre-"0-J Act tJex6-✓1T14 The above Engineers Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineers Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QU, WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-161 JAN - 5 2007 WATER QUALITY SECTION 3HEVILLE REGIONAL OFFIC ADDITIONAL FINAL COMPLETION CERTIFICATION I, ROBERT PAUL PATTERSON, as a duly Registered Professional Engineer in the State of North Carolina, having been recently authorized to review and asbuilt the construction of the project, Gann Village, for the permittee hereby state that, to the best of my abilities and knowledge**, that the construction along the main trunk line (manhole to manhole) was built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials (i.e., in accordance with 15A NCAC 2H .0200). Seal Signature: 1H�u un 4ri r �N CgRpli �% ti ��FESS/p29 q ', SEAL f a 023131 ez_ Robert Paul Patterson, P.E. N.C.P.E.4023131 NCDENR Permit No.: WQ0019927 P&P Project Name: Gann Village, Sewer As-builts P&P Project No.: 04-12-86-ENG Date: 12117,1 Ol. ** I conferred with Mr. Dennis Frady of the City of Hendersonville concerning this project and found out the following information: the main sewer extension had been camera tested to verify that the construction of said extension was in compliance with the standards set forth by the City of Hendersonville and NCDENR. It was mutually agreed upon, as a result of this test and field inspections, that the sewer extension met the requirements as set forth by the City of Hendersonville, NCDENR, and the original design engineer to the best of our knowledge and beliefs. I JAN - 5 2001 I DII WATER QUALITY SECTION Dreg Newman Mayor Barbara Volk Mayor Pro-Tem Chris A. Carter City Manager V11— CITY OF HENDERSONVI-L, E' "The City of Four Seasons" WATER AND SEWER DEPARTMENT Lee. Smith, Utilities Director Monday, October 9, 2006 Mr. Roger Edwards, Supervisor Surface Water Protection — ARO NC Department of Environment and Natural Resources 2090 U.S. Highway 70 Swannanoa, NC 28778 RE: NOV 2006 PC-0384 - RESPONSE PERMIT NO. WQ0019927 — GANN VILLAGE CITY OF HENDERSONVILLE Dear"Mr. Edwards: �,. _"CITYCOUNCIC'-` BARBARA VOLK, D E G. E �. VONt�Uc�rre ll2 5 �i.Il�'a)I �• JEFFC U OCT 1 3 2006 WATER QUALITY SECTION ASHEVILLE RFC'ONAL OFFICE The City of Hendersonville ("city') received your dated September 12, 2006 (attached), on Thursday, September 14, 2006 regarding the above referenced notice of violation (NOV). Upon his receipt of your letter, Mr. Paul Patterson, P.E., with Patterson & Patterson, contacted my office to set a time to discuss these matters. On Friday, September 15, 2006 city staff met with Mr. Patterson in an effort to resolve the matters addressed in your letter. In reference, to No. 1 in your letter, Mr. Patterson will be resubmitting his engineer's certification on the form provided in the permit to NCDENR. After discussing No. 2, in your letter, with Mr. Patterson, we have concluded that.the "as -built" data for the Gann Village project is incomplete and inaccurate. As a result of this' situation, the city has requested that Mr. Patterson survey the entire water and sewer systems associated with the Gann Village development. Upon completion of this survey, Mr. Patterson will be submitting a set of updated "as -built" drawings (water and sewer) to the city and to the state for your records. Mr. Patterson anticipates completing this work within 30-days after receiving written authorization from the city to proceed (see attachment). 305 Williams Street Phone: (828) 697-3063 Hendersonville, NC 28792-4461 Fax: (828) 697-3089 e-mail: lsmithr+cityofhendersonville.org v .cityofhendersonville.org NOV 2006 PC-0384 - RESPONSE PERMIT NO. WQ0019927 — GANN VILLAGE CITY OF HENDERSONVILLE PAGE 2 We would like to thank you in advance for your consideration of this matter and shall await your comments, if any. Please let Dennis Frady or me know if you have any questions or require additional information regarding this matter. ' cerely, ' e Smith Utilities Director Attachments cc: Chris Carter, City Manager Dennis Frady, Assistant Utilities Director Paul Patterson, P.E., Patterson & Patterson Michael F. Easley, Governor William G. Ross Jr, Secretary North Carolina Department of Environment and Natural Resources September 12, 2006 CERTIFIED MAIL RETURN RECEIPT REQUESTED 7005 3110 0003 5474 0158 Mr. Lee Smith, Utilities Director City of Hendersonville Post Office Box 1670 Hendersonville, North Carolina 28793-1670 SUBJECT: Notice of Violation NOV 2006 PC-0384 Fast Track Program Certification Audit Project Name: Gann Village Permit No. WQ0019927 County: Henderson Dear Mr. Smith: Alan W. Klimek, P.E. Director Division of Water Quality SEP 1 4 2006 of The subject project has been randomly selected and reviewed as part of the Division's Fast -Track Program Audit. Under the Fast -Track program, initial design documents are not reviewed prior to permitting by the Division as the professional engineer certifies that the project design is in accordance with our rules and minimum design criteria. This audit process ensures the terms of the Fast -Track program are followed, by technically reviewing the final design and construction record documents. Our audit disclosed the following deficiencies in the design, construction, and/or certification of the permitted project: 1. The engineering certification was not provided on the appropriate page of the issued permit (Ref. Permit No. WQ0019927, City of Hendersonville, Gann Village Wastewater Collection System Extension, Engineer's Certification); 2. A profile view of the sewer lines was not provided on the record drawings. Thus, information necessary to ascertain that the minimum design criteria have been met, including piping diameters, minimum cover, materials of construction, and vertical separation from water mains and storm sewers, is not available. (Ref. Permit No. WQ0019927, City of Hendersonville, Gann Village Wastewater Collection System Extension, Engineer's Certification); No `hCarolina Jl�rrtura!!� North Carolina Division of Water Quality 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone (828) 296-4500 Customer Service Internet www.nmaterquality.org PAX (828)299-7043 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper Mr. Lee Smith, Utilities Director September 12, 2006 Page 2 Due to the nature of the violations discovered during the audit process, it will be necessary for the City of Hendersonville to take any necessary corrective action to bring the project into compliance with the Division of Water Quality's NCAC 2H .0200 rules, the permit, and our minimum design criteria document(s). The City of Hendersonville, as the Permittee, is responsible for ensuring compliance. Violations of Water Quality Statutes and Regulations can result in the assessment of civil penalties of up to $25,000 per day, per violation. Please inform the DWQ Asheville Regional Office, in writing, within 30 days of the receipt of this letter regarding the expected corrective action that will be taken and the timeframe for completion. Based on the response, a permit modification may be required. If you have any questions concerning this matter, please do not hesitate to contact Roy Davis or Don Price at (828) 296-4500. Sincerely, �Rv 4!�' - Roger C. Edwards, Supervisor Surface Water Protection drp/bsr cc: Robert Paul Patterson, P.E.; Patterson & Patterson Bobby Blowe, P.E. Daniel Blaisdell, P.E. Larry Horton, P.E. Seth Robertson, P.E. PERCS Unit SWP Central Files PATTERSON & PATTERSON PAUL PATrERSON WILLUME PATTERSON PROFESSIONAL ENGINEER/LANDSURVEYOR PROFESSIONAL LAND SURVEYOR P.O. BOX 1189 HENDERSONVILLE, NC 28793-1189 1-828692-6629 (TEL & FAX) MEMORANDUM TO: DENNIS FRADY, ASST. UTILITY DIRECTOR @ CITY OF HENDERSONVILLE FROM: PAUL PATTERSON, P.E./P.L.S. DATE: SEPTEMBER 25, 2006 RE: PROPOSAL FOR SURVEYING & ENGINEERING AS-BUILTS FOR GANN VILLAGE (WATER AND SEWER SYSTEM) PLEASE FIND BELOW THE PROPOSAL FOR FIELD LOCATING BOTH EXISTING WATER AND SEWER SERVICES AND MAINS FOR GANN VILLAGE FOR THE PREPARATION OF SURVEYING AND ENGINEERING AS-BUILTS THE WATER SYSTEM AS-BUILTS WILL INCLUDE THE LOCATION OF VALVES, METERS, FIRE HYDRANTS, APPROXIMATE WATER LINE LOCATION AND DEPTH, AND OTHER APPURTENANCES. (WATER MAINS AND APPURTENANCES SHALL BE MARK BY THE CITY OF HENDERSONVILLE PRIOR TO FIELD SURVEY.) 2. THE SEWER SYSTEM AS-BUILTS WILL INCLUDE THE LOCATION OF MANHOLES,CLEANOUTS, ETC. AS KNOWN IN THE FIELD. (THE SEWER LATERALS WILL BE APPROXIMATE IN LOCATI(N.) THE SEWER SYSTEM WILL BE LOCATED FROM GANN VILLAGE TO THE MAN INTERCEPTOR LINE LOCATED WITHIN HAYWOOD TOWNES. OTHER MANHOLES WILL BE LOCATED AS NEEDED. 3. ANY ADDITIONAL WORK NOT INCLUDED IN THE ABOVE ITEMS SHALL BE AGREED UPON BY THE CITY AND PATTERSON & PATTERSON IN WRITING, WITH AN ADDITIONAL FEE BEING NEGOTIATED AT THAT TIME. (TOTAL ESTIMATE: $2,700) THIS WORK SHOULD BE COMPLETED WITHIN 30 DAYS (WEATHER PERMITTING) AFTER RECEIPT OF WRITTEN AUTHORIZATION TO PROCEED. WE LOOK FORWARD TO WORKING WITH YOU ON THESEAS-BUILTS. SHOULD YOU HAVE ANY QUESTIONS OR NEED ANY ADDITIONAL INFORMATION PLEASE DO NOT HESITATE TO CALL. THANKS IN ADVANCE FOR YOUR ASSISTANCE IN THIS MATTER. SINCERELY, PAUL PATTERSON, P.E./P.L.S. ENGINEERING - SURVEYING - PLANNING Associates Engineering Services, PA Structural & Civil Engineering Commercial & Residential June 7, 2006 NCDENR 2090 US HWY 70 Swannanoa, NC 28778 RE: Charleston at the Meadows Villages of Southwood Hendersonville, NC WQ0028574 To Whom It May Concern: Michael F. Connor, PE Chief Operating Officer Arthur C. Broadbooks, PE Director of Engineering Samuel R. Strickland, PE Senior Engineer Bruce Watson, RA Director ofArchitedure M JUN - 9 2006 WATER OWALITy SECTION The water and sewer is still under construction at the above referenced project. We assume since the project is still under construction that the permit is still valid. Since this is under construction we assume that the water permit and sewer permit has not expired and will be good for six months or until construction is complete. If this assumption is not correct, we request that you respond to us in writing within the next ten days otherwise we will assume that this is correct. Please do not hesitate to contact us should you have any questions. Sincerely, David R. Day, DRD/irt (828) 277-3292 (ph) 6 Roberts Road (828)277-3993 (fax) Asheville, NC 28803 n etJs� pg�; i�_c.il,ael F. Easley, Govemor E. WdtiWG. Ross Jr., Secretary North',,, i61 na Dep cnt o ironmenr6rulvammi Resources September 12, 2006 CERTIFIED MAIL RETURN RECEIPT REQUESTED 7005 3110 0003 5474 0158 Mr. Lee Smith, Utilities Director City of Hendersonville Post Office Box 1670 Hendersonville, North Carolina 28793-1670 SUBJECT: Notice of Violation NOV 2006 PC-0384 Fast Track Program Certification Audit Project Name: Gann Village Permit No. WQ0019927 County: Henderson Dear Mr. Smith: Alan W. Klimek, P.E. Director Division of Water Quality The subject project has been randomly selected and reviewed as part of the Division's Fast -Track Program Audit. Under the Fast -Track program, initial design documents are not reviewed prior to permitting by the Division as the professional engineer certifies that the project design is in accordance with our rules and minimum design criteria. This audit process ensures the terms of the Fast -Track program are followed, by technically reviewing the final design and construction record documents. Our audit disclosed the following deficiencies in the design, construction, and/or certification of the permitted project: 1. The engineering certification was not provided on the appropriate page of the issued permit (Ref. Permit No. WQ0019927, City -of Hendersonville, Gann Village Wastewater Collection System Extension, Engineer's Certification); 2. A profile view of the sewer lines was not provided on the record drawings. Thus, information necessary to ascertain that the minimum design criteria have been met, including piping diameters, minimum cover, materials of construction, and vertical separationfrom water mains and storm sewers, is not available. (Ref. Permit No. WQ0019927, City of Hendersonville, Gann Village Wastewater Collection System Extension, Engineer's Certification); NorthCarolina Ivatlaully orth Carolina Division of Water Quality 2090 U.S. Highway 70 Swammmoa, NC 28778 Phone (828) 2964500 Customer Service Intemet www.ncwaterquailty.org FAX (828) 299-7043 1-877-623-6748 qual Opportunity/Affirmative Action Employer— 50% Recycled/70% Post Consumer Paper Mr. Lee Smith, Utilities Director September 12, 2006 Page 2 r , Due to the nature of the violations discovered during the audit process, it will be necessary for the City of Hendersonville to take any necessary corrective action to bring the project into compliance with the Division of Water Quality's NCAC 2H .0200 rules, the permit, and our minimum design criteria document(s). The City of Hendersonville, as the Permittee, is responsible for ensuring compliance. Violations of Water Quality Statutes and Regulations can result in the assessment of civil penalties of up to $25,000 per day, per violation. Please inform the DWQ Asheville Regional Office, in -writing, within 30 days of the receipt of this letter regarding the expected corrective action that will be taken and the timeframe for completion. Based on the response, a permit modification may be required. If you have any questions concerning this matter, please do not hesitate to contact Roy Davis or Don Price at (828) 296-4500. Sincerely, Roger C. Edwards, Supervisor Surface Water Protection drplbsr cc: Robert Paul Patterson, P.E.; Patterson & Patterson Bobby Blowe, P.E. Daniel Blaisdell, P.E. Larry Horton, P.E. Seth Robertson, P.E. PERCS Unit SWP Central Files Pe of North Carolina epartment of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Kerr T. Stevens, Director Division of Water Quality WCDENR NORTH CAROUNA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WATER QUALITY SECTION Mr. Ezra Allman, Director Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793 Dear Mr. Allman: April 27, 2001 SUBJECT: Permit No.WQ0019884 City of Hendersonville Brittany Place Wastewater Collection System Henderson County In accordance with your application received April 12, 2001, please find attached Permit No. WQ0019884 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina - Licensed Professional Engineer to the licensing board. Ezra Allman April 27, 2001 Page Two In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 2,114 linear feet of eight (8) inch gravity sewer to serve the Brittany Place Apartments as part of the City of Hendersonville's project and the discharge of 40,320 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received on April 12, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, AerrTlievens A Enclosure xc: Henderson County Health Department Non -Discharge Permitting Unit Bill Lapsley Roy Davis NORTH CAROLINA . - ENVIRONMENTAL -MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become. voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent - discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. ` b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. High -priority sewer lines shall be inspected at least once per every six-month period of time. d. A general observation of the entire sewer system shall be conducted at least once per year. f. Inspection and maintenance records shall be maintained for a period of at least three years. g. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1 C. 4. This permit shall not be transferable. In the event there is a desir7for e wastewfacilities to change ownership, or there is a name change of the Permformal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143- 215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or incapable of adequate wastewater transport, pumps, line blockage or breakage, etc.; or unknown reasons, that renders the facility such as mechanical or electrical failures of b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 27th day of April, 2001. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0019884 Permit No. WQ0019884 April 27; 2001 - ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Brittnay Place Hendersonville, NC Henderson County for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 NPDES FACILITY AND PEEM"IT DATA 04/16/01 15:39:00 TRXID 50U KEY % FE 1u9;' $f4^y DATA FACILITY APPLYING FOR PERMIT APP/PERMIT FEE-$ 400.00 REGION ILITY NAME> HENDERSONVILLE, CITY-BRI-.TTANYI COUNTY> HENDERSON 01 ADDRESS: MAILING (REQUIRED) ENGINEER: WILLIAM G. LAPSLEY & ASSC STREET: PO BOX 1760 STREET: PO BOX 546 CITY: HENDERSONVILLE ST NC ZIP 28793 CITY: HENDERSONVILLE ST NC ZIP 28793 TELEPHONE 828 697 3063 TELEPHONE: 828 697 7334 STATE CONTACT> SERG/ARO FACILITY CONTACT EZRA ALLMAN TYPE OF PROJECT> SEWER -PUBLIC LAT: LONG: DATE APP RCVD 04/12/01 N=NEW,M=MODIFICATION,R=REISSUE> N DATE ACKNOWLEDGED 04/16/01 DATE REVIEWED / / RETURN DATE REG COMM REQS / / DATE DENIED / / NPDES #- REG COMM RCVD / / DATE RETURNED / / TRIB Q .0000 MGD ADD INFO REQS / / OT AG COM REQS / / TRIB DATE- ADD INFO RCVD / / OT AG COM RCVD END STAT APP P 07/11/01 DATE ISSUED / / DATE EXPIRE FEE CODE( 7)1=(>lMGD),2=(>IOKGD),3=(>lKGD),4=(<1KGD+SF),5=(S>300A),6=(S<=300A), 7=(SENDEL),8=(SEDEL),9=(CLREC),0=(NO FEE) DISC CODES 01 07 ASN/CHG PRMT ENG CERT DATE / / LAST NOV DATE / / CONBILL( ) COMMENTS: MESSAGE: *** DATA ADDED SUCCESSFULLY *** 0 80KM G. LAPSLEY & ASSOC., P.A. P.O. BOX 546 HENDEPSONVIDE. NO 28193 9"i��Ob19�a�� PAY rFOUR�HUNDRED DOLLARS AND NO CENTS TOTNE ORDER NCDENR TOTHE OF: APR 1 V 9 2001 7M MR,T CNREN69ANK l TPNST COMPANY 020120 .�.. N6No6wwxnue,xc mrn 663J1531 ****x***f*i*x**xix*ikx***fix*ifix*fi*i***xx*.fi DATE AMOUNT 1,,1 $400.00 0u' t:053100300"S61131346311' u ' CITY COUNCIL: = CITY .OF HE'NDERSONVILLE . ..a H'Niehoff, Jr. , J. CRrr7ENDEN HARLEY . Mayor The City of Four Seasons'.' ' Mary Jo Padgett ' , " R'E C El•V E'D - LONDA MURRAv •Mayor.P ter ' WATER AND SEWER DEPARTMENT: •'• WATERQlJliLITYSECTWJOPADGM , ChnsA .Carter - , ' city Manage[ ' F_ara Allman;,Dire' dor ; n ��r Tammie`[{. Drake - - e mail: eallman@cityofhender'sonviue.org - • tl�I", 2GUGI BARBARA VOLK City Clerk NornDlschargs Permitting, LETTER OF TRANSMITTAL - Mr: Kiin,H. Colson,'P.E., Supervisor April •10, 2001, , N. C,; Departmeni of Environment & Natural Resources Division of Water -Quality, ` 1617`Mall Service Center- ^' Raleigh, N;C. 27699-1637 Att'ached,.'we are `sending -you ( THREE (3) COPIES 6f FAST"TRACK APPLICATION FORMS, &i,�A CHECK in the AMOUNT of $40D,,and,(' ONE COPY of, a CAPACITY, ` ACCEPTANCE LETTER •) ,for a proposed ( SEWER LINE EXTENSION. to _serve , BRITTANY PLACE+APARTMENTS Yin Henderson -County, North'.Carolina.,- f This project is,,being forwarded to you for your review and approval r d' rSubmittcd By`, ) _ Water .and Sewer Department; . CIT.Y''w HENDERSONVILLE cc rProject Fine. '318'Fourth Avenue. East - P.O. Box 1760. "Phone. '(828) 69.7-3063 Hendersonville, NC' 28792-4428 Hendersonville,NC 28793.1760� Faxi � (828),697-1707 e-mait:'wsdept@ciNofhendersonville.org. w. - „ wviw_cityofhendecsonville.or9, CITY OF HENDERSONVILLE CITY COUNCIL: .a H. Niehoff, Jr. Mayor "The City of Four Seasons" . J. CR[TTENDEN HARLEY Mary Jo Padgett _ LONDA.MURRAY Mayor Pro -Tern Chris A. Carter WATER. AND SEWER DEPARTMENT MARv JO PADGEIT City Manager Ezra Allman, Director Tammie K. Drake e-mail: eallman@cityofhendersonville.org BARBARA VOut City Clerk ' April' 10, 2001 Mr. Kim H. Colson, P.E., Supervisor N. C. Department of Environment•& Natural Resources 1 wgTFq�CI�/ Division of Water Quality 1617 Mail Service Center Raleigh, N.C. 27699-1617 Re: CAPACITY ACCEPTANCE LETTER �» Sewer Line Extension Brittany Place, Apartments . Dear Mr. Colson: This is to advise you that I have reviewed the plans and specifications prepared by Mr. William G. Lapsley,�P.E. of William G. Lapsley & Associates, P.A. for a proposed gravity sewer collection system to serve the referenced project. It is my opinion that the City of Hendersonville has the capacity to accept the additional wastewater flows that will be generated by this project. This project is being submitted via Fast Track for your review, and approval. ; If you have any questions, call me -at (828) 697-3063. Sincerely, JA 0-0a Allman, Director, Water and Sewer Department . CITY OF HENDERSONVILLE cc: Project file 318 Fourth Avenue East - P.O. Box 1760 Phone: (828) 697-3063 Hendersonville NC 28792-4428' Hendersonville, NC 28793-1760 - Fax: (828) 697-1707 e-mail: wsdept@cityofhendersonville.org - www.cityofhendersonville.org State of North Carolina Department of Environment and Natural Resources ti 4p °'oVr Division of Water Quality �20 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) �7 ,q THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL. INSTRUCTIONS: Indicate that you have included the following list of required application package items by signing your initials in the space provided next to each item. Failure to submit all required items will lead to additional processing and review time for the permit application. A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless You respond NO to item IV 6. and/or item IV 10 B. Attachment - Submit the completed and properly executed Form WSCA 10/99 for each watershed within the project location. C. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment ,pe and Natural Resources (NCDENR). Iv D. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately - owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area OJis contiguous to an existing franchised area, and/or that franchise approval is expected. E. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use t Form HOA 10/99. If the applicant is a developer, use Form DEV 10/99. {mot F. Flow Acceptance Letters — if the owner of the downstream sewers and/or W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and W WTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 NORTH SALISBURY STREET, SUITE 1219 RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 For more information, visit our web site at. h2o.enr state.ne.us/ndpu/ FORM: FTA 06100 Page 1 of 5 Application Number: A00 ft S (to be completed by DWQ) I. GENERAL INFORMATION: 1. Applicant's name (name of the municipality, corporation, individual, etc.): Lg_I OF V60b5gz;6 VILLe 2. Owner's or signing official's name and title (15A NCAC 2H 3. Name and complete address of applicant: City: State: Nk, zip: p6-73 Telephone number: (5a) (DR7' NOS Facsimile number: (B26) 691— 1`70l 4. Project name (name of the subdivision, facility or establishment, etc.): 5. County where project is located: � I mck--r—Do w Wow) ) 6. Fee submitted: S AOOi (See Instruction C.) 7. Name and complete address of engineering firm: City: hrV dEt(SOhV i KP_ State: N C- Zip: 28-793 Telephone number: (IBM) 10p(Iry —734 Facsimile number: (BcF7 ) 0 7 —7333 8. Name and affiliation of contact person who can answer questions about .1\L/t. /' . , �_� _ U. PERMIT INFORMATION: 1. Project is: new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number and the issuance date 3. Applicant is: — k_ public private If private, units (lots, townhomes, etc.) are: leased (Skip to item III.); sold If sold, facilities owned by a: III. INFORMATION ON WASTEWATER: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) I. Please provide a one- or two -word description specifying the origin of the wastewater (school, subdivision, hospital, com ercial facility, industry, apartments, condominiums, etc.): 2. Volume of wastewater generated by this project. :321-O'LJ gallons per day 3. Explanation of2 unis Pow wastewater flow was determined q( 5A NCAC 2H .0219(1)): 110 (20_ctal + IM UR[ IC Wazc[ = 4o. S20 4. Nature of wastewater: Domestic/Commercial; Industrial; % Other waste - specify: FORM: FTA 06/00 Page 2 of 5 5. If wastewater is industrial in nature: a. Level of pretreatment that has been provided to ensure protection of the receiving collection system and wastewater treatment facility: b. If a pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: 1. Brief project description: C�Rs`rueo� 2l �4 err t_u rv�� M 7f2 ro seYUE wt>nv1 2. Owner and name of wastewater treatment facility (WWTF) receiving wastewater (See Instruction F.): _ �=I U C en[i.y(50RUl�I 11 !! 3. WWTF perms number (NC00'•'•• or WQ00••"•): NC� 2rJrJ3� 4. List the owner(s) of any intermediate sewe,rs! if different from applicant or owner of WWTF (See Instruction F.): N�A 5. Summary of GRAVITY SEWER to be permitted: Diameter (inches) Length (linear feet) I 6. Does the subject gravity sewer collection system comply with the most recent version of the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200? A— Yes; No. If no, please identify criteria and explain: 7. Summary of PUMP STATIONS to be permitted: No. or Name Design Flow (MGD) Pump Operational Points GPM (a) TDH Reliability Option Selected FORM: FTA 06100 Page 3 of 5 8. Summary of FORCE MAIN to be permitted: Diameter Length (inches) (linear feet) 9. List any equipment being utilized that is not specifically mentioned elsewhere in the application or as part of the Minimum Design Criteria (e.g., telemetry, hoist, odor control equipment, mechanical bar screens, etc.): I 10. Do the subject pump stations and force mains comply with the Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains document adopted June 1, 2000 and 15A NCAC 2H .0200? Yes; No. If no, please identify criteria and explain: WAL NOTE: If you responded NO to item IVA and/or item IV.10. above, two (2) copies of detailed plans, specifications, supporting information, and any other materials pertaining to the identified criteria should be submitted with the completed and appropriately executed application form. FORM: FTA 06/00 Page 4 of 5 V. CERTIFICATIONS Professional Engineer's Certification: (, 1),11LLIRM 6 I, LRi� st that this application for 'JRltIALP�+E ALAI ME{1�5 �"tyr trlr—t u has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: rsa Applicant's Certification: 1. FLpU AILWO attest that this application for ��I�RN`��ReE AYaea Fs I J o G t -I has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil pen/ajltiQes�p tto,$25,000 per violation. f� Signature: CA Date: N!q Ror QEnV Et)sFCpoN AFq i roci Nolti01scharg9 1311mrito.9 FORM: FTA 06/00 Page 5 of 5 PAGE 01 State of Norte Carolina Department of EsvirttlotsleM sod Natural Resources Divides of Water Quality WATERSHED CLASSIFICATION ATTACHMENT Any changes made to this form will malt is the application being returned. , I •NIS• FORM MAY BE PHO719C'OPIED FOR USE AS AN ORIGINAL) w T INSTRUCTIONS. I o determine the clamrficatnon of the waW*Ad(s) in which the adtjed project will be located, you are required to 59r. submit this form. with Items I through 8 coapletacto do appropriate Division of Water Quality Regional Office Watcr Oualnv Supervisor (see Page 2 of 2) prior to sts M&W Of the application for review. At a minimum. you must include an 8 S" by I I" copy of the portion of a 7.5-®eutO USGS Topogniphie Map that shows the surface waters immediately downslope of the project You malt identify the loca000 of the Project and the closest downslope surface waters (waters for which you are requesting the dilmifiontim) oaths submitted map copy. If the &edify is located in the Neus: River Basin_ also include a copy of die soil s i vey nap for the project location. The con"pandins ago - discharge application my aot be sebea test tsisra this 11w a Is completed by the apprePtiate rsgioardeface and included with the subraittaL I Applicant's name (name of the municipality, corponbm; indlvldtttl, etc.): n it ' fW Vkelk-�9%520MVILLI~ 2 Namc and complete address of applicant: city j{_N {LLE state: Telephone number 3 Project name,(name of the subdivisio>rt, Sao or i a`lii 4 County where project is located % Namc(s) of closest surface waters zip: 20-79 3 — Facsimile number (62b ) ti River baani(s) in which the project is located: Wt,+�1 XAC 7 Topographic map name and date _�GLtI/l�v w 8 North Carolina Professional Engineer's sail, sillnaturs, and deft: TO: REGIONAL OFFICE WATER QUALITY SUPMVLSOR Please provide me with the classification(s) of the wtcfYea waters, watetsbcd(s), and these activities will occur• as identified on the attarbad ntap segment: Name(q) or surface waters and river basin(s): (A)O r_ JR- _.. Classification(s) (as established by the EMC): Proposed classificanon(s), if applicable. River basin 6uftcr rules. if applicable. . • Date' Page 1 of 2 Signature of regional office personnel. FORM WSCA 10ll99 river basin(s) where GK.. FB. �0�_.. OF ry� to State of North Carolina qp°��ycFi� Department of Environment and Natural Resources ° o, Division of Water Quality �sOhdcoo mA O f 2 FAST -TRACK APPLICATION m for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAIN S�� (Pressure sewers systems are not to be included as part of this application package) THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL. INSTRUCTIONS: Indicate that you have included the following list of required application package items by signing your initials in the space provided next to each item. Failure to submit all required items will lead to additional processing and review time for the permit application. A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. .Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed Plans and specifications unless you respond NO to item IV 6 and/or item IV 10 B. Attachment - Submit the completed and properly executed Forth WSCA 10/99 for each watershed within the project location. 11CiC7� C. Application Fee - Submit a check in the amount of S400 made payable to: North Carolina Department of Environment {�T and Natural Resources (NCDENR). I D. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately - owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area OJis contiguous to an existing franchised area, and/or that franchise approval is expected. E. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association; use Form HOA 10/99. If the applicant is a developer, use Form DEV 10199. `� IvF. Flow Acceptance Letters — If the owner of the downstream sewers and/or W WTF is different from the applicant, 1��""�� submit two copies of a flow acceptance letter from the owner of the downstream sewers and W WTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 NORTH SALISBURY STREET, SUITE 1219 RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 For more information, visit our web site at: h2o.enr state ticus/ndpa/ FORM: FTA 06/00 Pagel of S "�_ L LfA Application Number: (to be completed by owQ) GENERAL INFORMATION: I. Applicant's name (name of the municipality, corporation, individual, etc.): NF( of 1EF&EPWOVILLe 2. Owner's or signing official's name and title (15A NCAC 2H .0206(b)): �. RA pLLMR0.1 3. Name and complete address of applicant: t 11 0 X0( City: t�t�NDCC��,7f��7���ttiJ11(E 7,�State: NrC, zip: 28-7%3 Telephone number: (t)t=C�) ��T' 0(OS Facsimile number: 4. Project name (name of the subdivision, facility or establishment, etc.): 5. County where project is located: � MMIDL—M � WWI, 6. Fee submitted: $ Ft �lJ (``See Instruction C.) 7. Name and complete address of engineering firm: W r mi%bs s 6. City: hL2y deM0 KV i RP_ rr State: WC- zip: �Q26-793 Telephone number: ( ) (09 I ,33+ Facsimile number. (Bc©) �R7 --7333 8. Name and affiliation of contact person who can answer questions about PERMIT INFORMATION: 1. Project is: k new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number _ 3. Applicant is: __k public private and the issuance date If private, units (lots, townhomes, etc.) are: leased (Skip to item III.); sold If sold, facilities owned by a: III. INFORMATION ON WASTEWATER: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) 1. Please provide a one- or two -word description specifying the origin of the wastewater (school, subdivision, 2. Volume of wastewater generated by this apartments, condominiums, etc.): gallons per day 3. Explanation of Pow wastewater flow was determined ( 5A NCAC 2H .0219(I)): 112 uvt� s� 120 w + mogyd = 40 $20 4. Nature of wastewater: IDU % Domestic/Commercial; % Industrial; FORM: FTA 06/00 Other waste - specify: Page 2 of 5 5. If wastewater is industrial in nature: a. Level of pretreatment that has been provided to ensure protection of the receiving collection system and wastewater treatment facility: b. If a pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: 1. Brief project description: C©ns`ruovl, + z (l4 2. Owner and fame of wastewater treatment facility (WWTF) receiving wastewater (See Instruction F.): _ 3. WWTF permit'number(NC00""• or WQ00•'•'*): WC-00 Zb51 5+ 4. List the owner(s) of any intermediate sewe'rs! if different from applicant or owner of WWTF (See Instruction F.): N�� 5. Summary of GRAVITY SEWER to be permitted: Diameter Length (inches) (linear feet) 21[ 6. Does the subject gravity sewer collection system comply with the most recent version of the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200? A— Yes; No. If no, please identify criteria and explain: 7. Summary of PUMP STATIONS to be permitted: No. or Name Design Flow (MGD) Pump Operational Points GPM Q_ feet TDH Reliability Option Selected FORM: FTA 06/00 Page 3 of 5 8. Summary of FORCE MAIN to be permitted: Diameter Length (inches) (linear feet) 9. List any equipment being utilized that is not specifically mentioned elsewhere in the application or as part of the Minimum Design Criteria (e.g., telemetry, hoist, odor control equipment, mechanical bar screens, etc.): I 10. Do the subject pump stations and force mains comply with the Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains document adopted June 1, 2000 and 15A NCAC 2H .0200? Yes; No. If no, please identify criteria and explain: NOTE: If you responded NO to item IVA and/or item IV.10. above, two (2) copies of detailed plans, specifications, supporting information, and any other materials pertaining to the identified criteria should be submitted with the completed and appropriately executed application form. FORM: FTA 06/00 Page 4 of 5 V. CERTIFICATIONS Professional Engineer's Certification: �,t� [, I).11LLlRM 61 • LR%�st that this application for �P(IR ry ,`tom�YLy�e (AYFA�s� � RT vt�WL-t� has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and III N EEtL'�4Q REGOR`� 4�q`ol Applicant's Certification: ` I, Ft Ott AuMRIJ attest that this application for�R�RN`��RC'E Wh Mends cz)W I RIZY 4&4Wm S`- EM has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000�ass well as civil penalties up to $25,000 per violation. 7 Signature: C .12A 2 QAA Q/t, Date: 'i —� 1 FORM: FTA 06/00 Page 5 of 5 PAGE 01 Sate of Nortr Carollsa Department of Envirosa mt and Natural Resources Divides of Water Quality WATERSHED CLASSIFICATION ATTACHMENT �9rRF L Novo 4A20,� Any changes made to this form Will raRlt is the application being returned. ai�BA �O% r ! HIS1-"oRM MAY RE PHOrOCOP/ED FOR USE AS AN ORIGINAL) �O INSTRUCTIONS. I o determtnc the classification of the watersheds) in which the subject project will be located, you are required to submit this form. with Items I through 8 caa4kted. to the appropriate Division of Water Quality Regional Office Water Vuality Supervisor (see Page 2 of 2) prior to atbmetal of the application for review. At a minimum. you must include do a 5' by I I" copy of the partial of a 7.5-istisa to USGS Topographic Map that shows the sufwc waters immediately downslope of the project You tata idedfy the location of the project and the closest dowrulope surface waters (waters for which you are requesting the elal%latim) on the submitted map copy. If the fltcilityis located in the Neuse River Basin- also include ■ copy of the ado aavey a4 fbr the project location. The eorresptndfag non - discharge application aaay not be wMitW seta tdla aleya Is completed by the appropriate regional affice and included with the submittal 1 Applicant's name Guide of the rnuoicipal tN earpor dOn. tediviatal, etc.): C 1`( i 1-4pEr�ER50NV►��E _-- 2 Namc and complete address of applicant: 1 •�..�ax f17� -. n—r Cily-- -N � ��NppVI�LI< _ State: •1V �• Zip: 2C�19S .— Telephone number (�[Cl) _,- Fusindle number r (ON - f Pi olect name (name of the subdivisiwt, f►eity or erablahmnst. etc.): 3 County where project is located S Name(s)ofclosest vidacewaters__-- 6 River basin(s) in which the project is located: 7 Topographic map name and date �u V RfA 8 North Carolina Professional Engineer's Baal, ipuattn0. and date: _ : pF ONL - .cN - GR TO: REGIONAL OFFICE WATER QUALITY SUPERVISOR Please provide me with the clasiEcation(s) of the turlioe vistas, Wstanhed(s). and a to river basin(s) where these activities will occur, as identified on the tutacl trap p aegtna>ga m Nae(•i) of surface wags and river basin(s):j�V �O E N _. CHC._ e Ft B r Classification(s) (as established by the EMC): Proposed classificauon(s), if applicable. River basin buQcr rules, if applicable. Signature of regional office personnel. rORM WSC'A 10/99 QUA Date, Page I of 2 North Carolina epartment of Environment and -Natural Resources. - Asheville Regional Pffice Michael F. Easley, Governor William G. Ross, Jr., Secretary Kerr T. Stevens, Director Division of Water Quality FE/ A A - NCI)ENR ENVIRONMENT AND NATURAL RESOURCES WATER QUALITY SECTION Mr. Ezra Allman, Director Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793 Dear Mr. Allman: May 18, 2001 SUBJECT: Permit No. WQ0019985 Upward Development City of Hendersonville Wastewater Collection System Extension Henderson County - In accordance with your application received -on May 7, 2001, please find attached -Permit No. WQ0019985 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit, which requires that the wastewater- collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A N.CAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. Ezra Allman May 18, 2001 Page Two In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 250 linear feet of 12 inch and 450 linear feet of 8 inch gravity sewer to serve the Upward Development as part of the Upward Road project and the discharge of approximately 8040 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received on May 7, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected Hendersonville's Wastewater Treatment facility discharged into the receiving stream. by this system shall be treated in the City of (NPDES Permit No. NC0025534) prior to being If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, err W� evens��� Enclosure xc: Henderson County Health Department Non -Discharge Permitting Unit William G. Lapsley & Associates, P.A. Roy Davis W00019985per NORTH CAROLINA - ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design. Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall' be actively maintained. C. An operation and maintenance plan shall be developed and .implemented. d. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system, shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at le years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 213.0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification: Mail the Engineer's Certification, one copy of the -"Construction Record - Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NGG0100000, - and any requirements pertaining to wetlands -under 15A NCAC 2B-.0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting suchoccurrencesby telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 180' day of May, 2001. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION r rr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0019985 Permit No. WQ0019985 May 18, 2001 — ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Upward. Development , Hendersonville. NC Henderson County for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and, other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 State,of North Carolina RECEIVED Department of Environment and Natural Resources WAT=^'inirrvicen-nm Division of Water Quality MAY U % 2001 NON -DISCHARGE PERMIT APPLICATION GRAVITY SEWER COLLECTION SYSTEMS Non•Discharge Permitting (Pump stations, force mains and pressure sewers are not to be included as part of this application package.) (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) INSTRUCTIONS: Please indicate that you have included the following list of application requirements by signing your initials in the space provided next to each item. A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to the content of this form will result in the application being returned. The Division of Water Quality ...:'� (Division) will only accept application packages that have been fully completed with all applicable items addressed. ,' ➢,(/ Failure to submit all required items will lead to additional processing and review time for the permit application. (ice B. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). C. Flow Acceptance Letters — If the owner of the W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the W WTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/W WTF. The flow acceptance must not expire prior to permit issuanceand must bedated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project - specific, flow acceptance letter. D. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity hasnot been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area . is contiguous to an existing franchised area, and/or that franchise approval is expected. E. Operational Agreements — Submit one original and two copies of a properly executed Operational Agreement if the sewer extension will be serving residential or commercial lots (houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use Form HOA 10/99. If the applicant is a developer, use Form DEV 10/99. I. GENERAL INFORMATION: Application Number: ftb 6 `t; ✓ (to be completed by DWQ) 1. Applicant's name (name of the municipality, corporation, individual, etc.): _ C;� Ot W&JmcJVillG 2. Owner's or signing official's name and title (15A NCIIAC 2H .0206(b)): Earn. aumna . t %A� 1V DIYCfOt- 3. Name and complete address of applicant: L i i j 0� HewefnQWh I!G waizr • Sevrer D,-"7 i�me.,� �-'0'Boy 1iU0 city: NeNdersatVJle- State: NG zip: 28793 Telephone number: ( $i' ) CA7-3D(05 Facsimile number: (82$) 07-1707 4. Project name (name of the subdivision, facility or establishment, etc.): C)oWQ6 d. veLaa 5. County where project is located: An%lderaO4 FORM: GSPA 02/00 Page 1 of 4 r. Name and complete address of engineering m: _,iWi �) tam (Q. iII�S/G✓ t A,J, Kf}, Firm: r City: WeNda—Wo4vilk State: NG zip: 28753 Telephone number:'( 829) 4o97-733q Facsimile number: (808) 647 7333 7. Name and affiliation of contact person who can answer questions about application: _ ,rn ?_ R_�iG, E• . ln�r'I I'OM G' Gcoslz✓ H. PERMIT INFORMATION 1. Project is: X new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number and the issuance date 3. Applicant is: _ (�_ public private. If private, units (lots, townhomes, etc.) are; leased (Skip to Section III.) sold If sold, facilities owned by a: public utility (See InstructionD.); homeowners' association/developer (See Instruction E.) III. INFORMATION ON WASTEWATER: 1. Please provide a one- or two -word description specifying the origin of the wastewater (school, subdivision, hospital, commercial facility, industry, apartments, condominiums, etc.): Cnm lY orrod -Q61 , 11Y 2. Volume of wastewater generated by this project: 3. Explanation of how wastewater flow was determined,(15A tAl room X 120 dal 11061 1 TbDM c f3D- 5' 4. Nature of wastewater: 100 % Domestic/Commercial; % Other waste - specify: 5. If wastewater is industrial in nature: gallons per day 2H .0219(1)): % Industrial; a. Level of pretreatment.that has been provided to ensure protection of the receiving collection system and wastewater treatment facility: W k b. If a pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: 1„ Brief project description: L�2wzd Tk*AppRtl4..lamAq Sw6r 2. Owner and name of wastewater treatment facility (W WTF) receiving wastewater (See Instruction C.): C i �r c% v6der5om'c, W WTP 3. WWTF permit number (NC00***** or W000*****): NC 002553 FORM: GSPA 02/00 Page 2 of 4 4. Summary of GRAVITY SEWER to be permitted: , Diameter (inches) Length (linear feet) a" �t5o 5. Does the subject gravity sewer collection system comply with the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200? V Yes; No. If no, please identify criteria and explain: IMPORTANT: If you responded No to question IV.5 above, the completed application package, including two (2) copies of plans, specifications, supporting information and any other materials, should be submitted for an individual permit. The completed application package, including all supporting information and materials should be sent to the following address: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 By Courier/Special Delivery: 512 NORTH SALISBURY STREET, RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 FORM: GSPA 02/00 Page 3 of 4 V. CERTIFICATIONS: Professional Engineer's Certification: 1 `� I I, Wf I I f 11m G attest that this application for LJJ?Lk-' it O .1hVCaDPnlGli `7rN i TGry � -V'er has been reviewed by me and is accurate, complete and consistent with the information supplied in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations and Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: CAROIiy moo, ........... - f Quo SEAS _ 229s9 •FNGINE�•` "1 n u m+n Applicant's Certification: I j� I, EZIi', R 11mom attest that this application for UPWord +� 11JOPOW4 xN�TDIY 7C(/�r has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: 44za— COX%fr3yi C /t Date: d'Q / RE0 "' ED ION WATEROUAU MAV, p 7 2001 FORM: GSPA 02/00 Page 4 of 4 DIVISION OF WATER QUALITY REGIONAL OFFICES Asheville Regional Office WQ Supervisor 59 Woodfin Place Asheville, NC 28801 Phone: (828) 251-6208 Fax: (828) 251-6452 Avery Macon Buncombe Madison Burke McDowell Caldwell Mitchell Cherokee Polk Clay Rutherford Graham Swain Haywood Transylvania Henderson Yancey Jackson Raleigh Regional Office WQ Supervisor 3800 Barrett Drive, Suite 101 Raleigh, NC 27609 Phone: (919) 571-4700 Fax: (919) 571-4718 Chatham Nash Durham Northampton Edgecombe Orange Franklin Person Granville Vance Halifax Wake Johnston Warren Lee Wilson Winston-Salem Regional Office WQ Supervisor 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4600 Fax: (336) 771-4630 Alamance Rockingham Alleghany Randolph Ashe Stokes Caswell Sorry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford Fayetteville Regional Office WQ Supervisor Wachovia Building, Suite 714 Fayetteville, NC 28301 Phone: (910) 486-1541 Fax:(910) 486-0707 Mooresville Regional Office WQ Supervisor 919 North Main Street Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704)663-6040 Anson Moore Alexander Lincoln Bladen Robeson Cabarrus Mecklenburg Cumberland Richmond Catawba Rowan Harnett Sampson Cleveland Stanly Hoke Scotland Gaston Union Montgomery Iredell Washington Regional Office WQ Supervisor 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 946-9215 Beaufort Jones Bertie Lenoir Camden Martin Chowan Pamlico Craven Pasquotank Currituck Perquimans Dare Pitt Gates Tyrell Greene Washington Hertford Wayne Hyde Wilmington Regional Office WQ Supervisor 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Phone: (910) 395-3900 Fax: (910) 350-2004 Brunswick New Hanover Carteret Onslow Columbus Pender Duplin FORM: WSCA 10/99 Page 2 of 2 (• ✓ State 0f iii" cores" Department of E*YUV02 W tad Natarol Regoarces DwIdan of water Qm ty WATEYi mw cLASSEFICATEON ATTACi1MENT Any ehaneu made to thisf" tM i 1 11 in owggipbat5mbeft returned. (THIS FORM AU r RX PIf0T0C M pM MAS AY ORKIINAL) nvsinucflorbst To desermiae me CltaenCHJnUa of Q)e watsr>Zad(t) hr vhlaEr � �� �'t wlll he loured, you areil TO xfrvbajpa of Water Quality Regional nai OHL,r subur)t We facnk with itttma 1 throw er' for in iaw'. At a minimum you tnuet W aim amity s�viaor (MM Page 2 of 2) prh: ID0*6" of tbn shows the surface wslu] mchrde an 8.3" by I I" Copy of the partkM of ■ ' flees Tara/of & proper er and the cloEest dnvnnl,nn aruoedistely, dowatlope of do PWJCCL You go* iti•ft an 1�s d ttc po r A) Q eM tarbsnined tmrp copy. if the t., t.ry located wtitals (was you am [ s b IM the ect Uw:anoa The located 1n Nawe River aaia. goMVEst be M6010d � &b p as b eamphtad by the apprup...tr coRaspaadhK � t�o7 •et oast *Gk* and ioeladad teak the stthadltat. 1. ppplicaafs ttabbta (dame of rise �"Nd' et.): �� — 2. Namsledceatpkteaddtwofapp)fw �le 1;0 am r1w1 — - City: hl RMIe: Zip: �r�'J•i'_ ... ,. 3. J'tojod namC (acme of the subdiviaioa thellky «aAhl�°�R) —_ ._ 4. Coum wtwre ProJect is bcatatL• '— ----� S. Name(s) of closest tatrfaba womm 6. Rjvcr baain(t) in which the project is IOC Md: 7 ToposrsPW maP tmOe and date: L%—%, •,,, WipaseraMind OW.%v.v &. Nortb Caroliaa Ptof�+sm+l �� ��� 58 OI 'zfoFti cti9� 279Ag i 4 4- C)( ? IL �� Zi. ; 1 oHG.NfF JN TO: Ri(3tolVALOYMEWATCROUAIITVBUPSMVtitOR ':,r(►AM 0 ,I" ` Pleme provide we with the CbssiBWd*s) orbit swim Wales. was)' and a�rpnate�ii.'%Y Na 1inlsl where theae activities will emu, r WeaMetd m ilia atMdwi b4 �ror Name(s) of nufsee waRR sod nvta Class:ficanon(s) (as establisbed by 69 M14. proposed clamificatioaii(s). if applicable: River tbasin brffer rants, if applicable: Signature of fegionel otixx Perwoaoi: FORM: WSCA 10/99 pie i cf 2 'u �clGrl BS "( I IUULi bZi Sat E I `1J• 1 vl � �1� ; _� p 1 CO .. 12 u \ J.C. '�G �• ' 1� '°' Di O V' ieC •a ,p uqs, ubH e3'. Q — .. Tlal47tl �.��. � m'D •• it 9S � 00 ° 9B '� 'e. Oar• 'I .� -l; � ,� � ..,' Yam' a � � __ _'-__ � •. �� J ' � n a 40 1a4 •� •2/ ' I• i. Oy /va e n -- n •lyl6�/ 1 / r JI' - / - i tii Cr .Ln i� a r•I % 7 \`�� 51 n obgb ) \\ �! % � . 4 11 � �� ! _ 11 •. .1 � li � • � b 1 J.3ll✓A-33SSN1 I / >l'ed ail a ION NPDES FACILITY AND PERMIT DATA 05/09/01 09:53:20 ON TRXID SOU KEY WQ001.9985`-i,' L_. a.JwJ TA FACILITY APPLYING FOR PERMIT "APP/E*ERMIT FEE-$ 400.00 REGION PFDA ITY NAME> HENDERSONVILLE, CITY -UPWARD D1 COUNTY> HENDERSON 01 ADDRESS: MAILING (REQUIRED) ENGINEER: WILLIAM G LAPSLEY & ASSOC STREET: PO BOX 1760 STREET: PO BOX 546 CITY: HENDERSONVILLE ST NC ZIP 28793 CITY: HENDERSONVILLE ST NC ZIP 28793 TELEPHONE 828 697 3065 TELEPHONE: 828 697 7334 STATE CONTACT> SERG/ARO FACILITY CONTACT EZRA ALLMAN TYPE OF PROJECT> SEWER -PUBLIC LAT: LONG: DATE APP RCVD 05/07/01 N=NEW,M=MODIFICATION,R=REISSUE> N DATE ACKNOWLEDGED 05/09/01 DATE REVIEWED / / RETURN DATE REG COMM REQS / / DATE DENIED / / NPDES #- REG COMM RCVD / / DATE RETURNED / / TRIB Q .0000 MGD ADD INFO REQS / / OT AG COM REQS / / TRIB DATE- ADD INFO RCVD / / OT AG COM RCVD END STAT APP P 08/05/01 DATE ISSUED / / DATE EXPIRE FEE CODE( 7)1=(>lMGD),2=(>10KGD),3=(>IKGD),4=(<lKGD+SF),5=(S>300A),6=(S<=300A), 7=(SENDEL),8=(SEDEL),9=(CLREC),0=(NO FEE) DISC CODES 01 13 ASN/CHG PRMT ENG CERT DATE / / LAST NOV DATE / / CONBILL( ) COMMENTS: MESSAGE: *** DATA ADDED SUCCESSFULLY *** JEFFREYQJUSLIS NCD�5556951 1I (bj.Ys SpDO RONDA S. JUSTUS bL �� � W CRMT RD Pl48tB .Ml FWROCKNC 26MI De ^2 so-mwrs ov Ltoof the /J'C OA(Z $ 7100 ^_ �•�'� YrC..-o��� iF,V� �a Dollars 8 Rwmct MNma For �'6i`v wa{� /^��,�, ::253L70�6,: ❑877051073.. 50 'a� MAY 1 ^0 2001 CITY OF HENDERSONVILLE P. Niehoff, Jr. r y. Mayor "The City of Four Seasons" Mary Jo Padgett Mayor Pro-Tem , Chris A. Carter City Manager Tammie k. Drake City Clerk WATER AND SEWER DEPARTMENT Ezra Allman, Director e-mail: eallman@cityofhendersonville.org LETTER OF TRANSMITTAL CITY COUNCIL: J. CRn7ENDEN HARIF" LONDA MURRAY MARY JO PADGErr BARBARA VOLT( Mr.ICim H. Colson, P.E., Supervisor. RAC EI V.ED- May 1, 2001 N. C. Department of Environment & Natural Resources M#R oUAtITYSFCTION• Division of Water Quality r 1617 Mail Service Center Raleigh, N.C. 27699-1617, . Non•Disch"arge Permitting This project is being forwarded to you for your review and approval.. Submitted By:'( Water and Sewer Department 'CITY OF HENDERSONvrnt cc: Project File 318 Fourth Avenue East , Hendersonville, NC 28792-4428 , - e-mail: wsdept@cityofhendersonville.org P.O. Box 1760 Hendersonville, NC 28793-1760 Phone: (828) 697-3063 Fax: (828) 697.1707 wnvw: cityofhende rsonville.org CITY OF HENDERSONVILLE CITY COUNCIL: -.. H. Viehoff, Jr. " * J. CRft7ENDEN HARLEY Mayor • • 'I I "The City of Four Seasons". Mary Jo Padgett LONDA MURRAY Mayor Pro-Tem WATER AND SEWER DEPARTMENT Chris A. Carter MARY JO PADGM City Manager Ezra Allman, Director - Tammie K. Drake e-mail: eallman@cityofhendersonville.org RECEIVED BARBARA VOLK City Clerk - INgTFR.r1))gLITYSF P�lAY 1, 2001 2001 Mr. Kim H. Colson, P.E., Supervisor • Non - Di N..C'. Department of Environment & Natural Resources sehafg®`Pert" fng Division of Water Quality . 1617 Mail Service Center -Raleigh, N.C. 21699-1617 Re: CAPACITY ACCEPTANCE LETTER ; Sewer Line Extension " Upward bevelopment•. Dear'Mr. Colson: This is to advise you that I have reviewed'the plans and specifications prepared by Mr. William R. Buie, P.E. of William G. Lapsley & Associates, P.A. for a proposed gravity'sewer collection system to;servethe referenced project: It is my opinion that the City of Hendersonville has the capacity to accept the additional wastewater flows that will be gerieratedby this project: 'This project is being submitted via Fast Track for your review and approval. If you have any questions, call me at,(828) 697-3063. ' Sincerely, , E lman, Director Water and Sewer Department CITY OF HENDERSONVILLE r , cc: Project file 318 Fourth Avenue East - P.O. Box 1760 Phone: (828) 697-3063 Hendersonville', NC 28792-4428. Hendersonville, NC 28793-1760 Fax: (828) 697-1707 e-mail:. wsdept@cityofhendersonville.orgw v.cityofhendersonville.org State of North Carolina Department of Environment and Natural Resources Division of Water Quality p NON -DISCHARGE PERMIT APPLICATION RF�'E.�sEc¶oN GRAVITY SEWER COLLECTION SYSTEW (Pump stations, force mains and pressure sewers are not to be included as art of this application package.)U1 ( P P P (THIS FORMMAYBEPHOTOCOPIED FOR USEASANORIGINAL) Non-plschat9®Pemn�n� INSTRUCTIONS: Please indicate that you have included the following list of application requirements by signing your initials in the space provided next to each item. &�_A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to the content of this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. Failure to submit all required items will lead to additional processing and review time for the permit application. B. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). C. Flow Acceptance Letters- If the owner of the W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the W WTF. Flow acceptance letters must contain the following minimum information: applicant and project time, amount of flow accepted, and name and permit number of the receiving sewers/W WTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project - specific flow acceptance letter. D. Certificates of Public Convenience and Necessity - If the application is being submitted in the name of a privately owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. E. Operational Agreements - Submit one original and two copies of a properly executed Operational Agreement if the sewer extension will be serving residential or commercial lots (houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use Form HOA 10/99. If the applicant is a developer, use Form DEV 10/99. I. GENERAL INFORMATION: Application Number: UO� h� (to be completed by DWQ) 1. Applicant's name (name of the municipality, corporation, individual, etc.): _ C :� j of W&Jec5cin le- 2. `Owner's or signing official's name and title (15A NCAC 2H .0206(b)): 3. Name and complete address of applicant: L i'Iy Di- HeAOCCONVI I/G 1�.�nitr JrevrL'r �ef �T t�0 DY 11 U0 City: 14G,,&rSeNJiIle- State: NG Zip: Z87%3 Telephone number: ( 62 ) (n97- 3%0 Facsimile number:( 828) o ^7-1 %0% 1 Fi 4. Project name (name of the subdivision, facility or establishment, etc.): Jpwc LGVC�0�I7lWi 5. County where project is located: ebdemo.,J FORM: GSPA 02/00 �b Page 1 of 4 r. Name and completes address of engineering firm: W i I) iam r}. Loasl6✓ t rI �U046 C" f}. ?b 3X 5q% 1 City: eNJ05CIJV;& State: NL zip: 28793 Telephone number: ( 829) 07-733q Facsimile number:(S28) &V 7333 7. Name and affiliation of contact person who can answer gpestions about application: , II. PERMIT INFORMATION: 1. Project is: X new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number and the issuance date 3. Applicant is: _ ( public private. If private, units (lots, townhomes, etc.) are: leased (Skip to Section III.) sold If sold, facilities owned by a: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) M. INFORMATION ON WASTEWATER: 1. Please provide a one- or two -word description specifying the origin of the wastewater (school, subdivision, hospital, commercial facility, industry, apartments, condominiums, etc.): C.Dmmforc/GI "MLp li L4,oke_1 2. Volume of wastewater generated by this project: f�04o G ed gallons per day 3. Explanation of how wastewater flow was determined (15A NCAC 2H .0219(1)): io1 room X 12o ctal /c6y l 7eo/rl = ¢30g6 qpd 4. Nature of wastewater: 100 %Domestic/Commercial; % Other waste - specify: 5. If wastewater is industrial in nature: % Industrial; a. Level of pretreatment that has been provided to ensure protection of the receiving collection system and wastewater treatment facility: W k b. If a pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: 1. Brief project description: Upys� -Dkgolpgrn ..GN.+ty Seeger 2. Owner and name of wastewater treatment facility (W WTF) receiving wastewater (See Instruction C.): Cif c� 4 vJeoamillc. W WTP 3. WWTF permit number (NC00***** or W000*****): NC 0025531 FORM: GSPA 02/00 Page 2 of 4 4. Summary of GRAVITY SEWER to be permitted: Diameter (inches) Length (linear feet) 12" Z50 a" 45O 5. Does the subject gravity sewer collection system comply with the Gravity Sewer Minimum Design Criteria and 15A NCAC 211.0200? V Yes; No. If no, please identify criteria and explain: IMPORTANT: If you responded No to question IV.S above, the completed application package, including two (2) copies of plans, specifications, supporting information and any other materials, should be submitted for an individual permit. The completed application package, including all supporting information and materials should be sent to the following address: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 By Courier/Special Delivery: 512 NORTH SALISBURY STREET, RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 FORM: GSPA 02/00 Page 3 of 4 V. CERTIFICATIONS: Professional Engineer's Certification: 1 I I, Wi l l i lm ? � e attest that this application for () PLLWd OPf11PAtt —RCN i 7GN J[ V'e has been reviewed by me and is accurate, complete and consistent with the information supplied in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations and Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification: I j� I, Ezm R llmOhl attest that this application for UPWOrrl •✓yJ0pM&4 xIYiTDN 7ClJ Z! has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: A jr p:-- Date: RECEIVED WA-mD In inl rry carTION M6Y u 1 21itI] FORM: GSPA 02/00 Page 4 of 4 Nnn'!ye©halga Permitting DIVISION OF WATER QUALITY REGIONAL OFFICES Asheville Regional Office WQ Supervisor 59 Woodfin Place Asheville, NC 28801 Phone: (828) 251-6208 Fax: (828) 251-6452 Avery Macon Buncombe Madison Burke McDowell Caldwell Mitchell Cherokee Polk Clay Rutherford Graham Swain Haywood Transylvania Henderson Yancey Jackson Raleigh Regional Office WQ Supervisor 3800 Barrett Drive, Suite 101 Raleigh, NC 27609 Phone: (919) 571-4700 Fax: (919) 571-4718 Chatham Nash Durham Northampton Edgecombe Orange Franklin Person Granville Vance Halifax Wake Johnston Warren Lee Wilson Winston-Salem Regional Office WQ Supervisor 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4600 Fax: (336) 771-4630 Alamance Rockingham Alleghany Randolph Ashe Stokes Caswell Surry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford Fayetteville Regional Office WQ Supervisor Wachovia Building, Suite 714 Fayetteville, NC 28301 Phone: (910) 486-1541 Fax: (910) 486-0707 Mooresville Regional Office WQ Supervisor 919 North Main Street Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Anson Moore Alexander Lincoln Bladen Robeson Cabarrus Mecklenburg Cumberland Richmond Catawba Rowan Harnett Sampson Cleveland Stanly Hoke Scotland Gaston Union Montgomery Iredell Washington Regional Office WQ Supervisor 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 946-9215 Beaufort Jones Bertie Lenoir Camden Martin Chowan Pamlico Craven Pasquotank Currituck Perquimans Dare Pitt Gates Tyrell Greene Washington Hertford Wayne Hyde Wilmington Regional Office WQ Supervisor 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Phone: (910) 395-3900 Fax: (910) 350-2004 Brunswick New Hanover Carteret Onslow Columbus Pender Duplin FORM: WSCA 10/99 Page 2 of 2 tin/ Z7/ Ltltll in: 1 / 05!29!"Ilnl 1 1: 50 PAGE 02 F'NiE m area Ljo i chi 66101 VZ)SM :MOd :pnwuad aayjo leaOSM Jo asnlea!S ;QRMddz i! .(,)„o0e3t3!nvI, pasodOM :(:IjU I% Aq pa9s41g4tl Se) (t)Lc°neag!sttlO :(g)*Sq mAi pm sulw a3q=3� f Z* &W PsSAP 90 m WSIPW w •macro rtlm same 3"9p dutdds pa'(t)Pt4mwqL tlMA iAf= 3o a -IT tea' 7ta Mk" atteld " N WbI) SOMLtlk2iILYiL[P1YaoWUVMZ�X11 WIJO1DIS :Ol GBGGZ �ti N Of SS- �'�,r{f0 � JUG 'wy`V\J.-' �;�}s,'e�r�1�4a�o3l��Jwdsd!lanJ�=Md '8 .,....,1„ :Mtp pum aum dm MdROtodo.L -L obbi _ • _--- -- _ _ :p�eool a laefoad tN 4"4� dl b��'a"R1 .9 16�q-Mau -map" mma= l+atola Jo (s)21=N 'S '1 ✓ : K5301 s+ rn(wd "M AlonaJ L waDpdbio-m*;m asaidmoD put ammm 'Z :(= growlel" 'Im!pollim amen) ouu tjmagddV 'I TAIMia N19Mr+ NPlad! p1Oe W3091e20130a aF.,,"idd■aLLlggPOPOV=`tlULM<SMIM�K�'�aOW-mmoplandft 22OLK +o° °J a4.1. °ouej Faafad alp mj dwt �r A De LdW a � �� a.a ssaaeM) aspwe wums al ti, . ,rl xp JI '�Cdoa duea patyunq�� eq w (ee�llwwl«f A aaf lwd ep!q 'D] s u• ,tual. Jsa a 3111 FF= sa:{od .10 jo Isaim so 4p� p� 80� 7ao(oad Jo adolsa"`°p 6tpnDa°u'u Ci3irm aj pns ayl mogI M deN M"WIDJ:1 n 011FIRT1 a JO Yol{td 2g1Jo .tdaa 'I' A4 .S'Y ow 1,nlfl °°A YonuitliIIl t 1V •n0!U11g UOMOO fJf!♦Jo q m{d (Z Jo Z -lftd go) m"2dnS Aq!lob 11RIA1 ,...uu (suo�8a)l la,len� 1mK, jv !"!Q �P✓ t 4'p�t[d�D tp 1 smsal spire mw} In "opIllaO ui pamlFai al® n°[ 'Mtnol ay IIUe SaDjbet »��'�� (�)agtiatw aq1 po ROge.r9�tttlD o� aacw1 (7VAfYrMO A, V NY 07 mW ajWWOWArdffHA"Y/N*O!SIMI) -pacuaqu 9oaq > M so ■1 ;,� am @jLMq Slip op ep *m safasyla XW .LN:qW,,:)V.LLV NOLLyC)j IIS9'VjD oXffS:II.I.VA9 4150b ""ALP I OPM saaxaoxaX le-pnrN pW 3!Mw@a4Ae$ jo aoampada(l wl":) "N;o asns H -. I . 4. 41, Al .fir', i..Tt�1Ci,"1 �pj: 1-11 M "l i / i c [T . rL\_ I 3 w thallm li �� 0, Ell •�i .• � �_sb ii� \ �I �n NVjI�� �\ • � i� •• 1 d\ /, q /l IN Lam:_ o JMAI 3141tl � • : � �,Il ci `•':�•_ 'ads •yu3D ni op V I 7 99 i Icl. \ e IZ 41� p to a •• u TECHNICAL SPECIFICATIONS I UPWARD DEVELOPMENT SANITARY SEWER IMPROVEMENTS CITY OF HENDERSONVILLE HENDERSON COUNTY, NORTH CAROLINA ,Milli ? 22989 PREPARED BY: WILLIAM G. LAPSLEY & ASSOCIATES, P.A. CONSULTING ENGINEERS 1635 ASHEVILLE HIGHWAY RECEIVED HENDERSONVILLE, NORTH CAROLINA WATERC)IIAI.RY.Q=r%Tl()N APRIL 2001 MAY U % !, Non -Discharge Permitting SECTION 07110 SEWER PIPE (GRAVITY) AND APPURTENANCE MATERIAL 07110.1 SCOPE These specifications shall furnished and installed to installations in accordance appurtenances shall be of the plans and designated herein. 07110.2 GENERAL apply to the materials to be complete the sanitary ,sewer line with the plans. All pipe and class and type as indicated on the All materials shall be first quality with smooth interior and exterior surfaces, free from cracks, blisters, honeycombs and other imperfections, and true to theoretical shapes and forms throughout. All materials shall be subject to the inspection of the Engineer at the plant, trench, or other point of delivery, for the purpose of culling and rejecting materials, which does not conform to the requirements of these specifications. Such material shall be marked by the Engineer and the Contractor shall remove it from the project site upon notice being received of its rejection. As particular specifications are cited, the designation shall be construed to refer to the latest revision under the same specification number, or to superseding specifications under a new number except provisions in revised specifications which are clearly inapplicable. Polyvinyl Chloride Pipe Polyvinyl Chloride (PVC) pipe shall meet the requirement of ASTM D 3034, latest edition, and be suitable for use as a gravity sewer conduit. The standard dimension ratio (SDR) shall be thirty-five (35) unless otherwise specified. The pipe shall be supplied in standard laying lengths of twenty (20) feet and twelve and one-half (12.5) feet. All PVC pipe joints shall be of an integral bell and spigot of the same material as the -pipe with a solid cross-section rubber "O" ring securely locked in place at the point of manufacture. Service saddles and other fittings manufacturer and shall be of the construction as the pipe material. 07110-1 shall be supplied by the pipe same material and type of Ductile Iron Pipe Ductile Iron Pipe shall be manufactured in accordance with ANSI Specification A 21.51. All Ductile Iron Pipe shall be Class 50 unless otherwise specified and shall be lined with cement mortar not less than one sixteenth (1/16) inch thick conforming to ANSI Specification A 21.4. Slip or "push -on" joints shall be manufactured in accordance with ANSI Specification A 21.11. Bells of "slip" joint pipe shall be contoured to receive a bulbshaped, circular rubber gasket, and plain ends shall have a slight taper to facilitate installation. The lubricant used in making up the joints shall be furnished by the pipe manufacturer. The jointing shall be done by guiding the plain end into the bell until contact is made with the gasket and by exerting a sufficient compressive force to drive the joint home until plain end makes full contact with the base of the bell. Steel Casing Pipe Steel casing shall conform to ASTM A-53, Grade B or ASTM A-139 Grade B standard specifications. Casing pipe shall have a wall thickness as follows, unless otherwise noted in the bid documents: 12" thru 24" casing 30" casing 36" casing 07110.3 MANHOLES - 0.250 inches wall thickness - 0.312 inches wall thickness - 0.375 inches wall thickness Precast concrete manhole bases, risers and cones shall conform to ASTM C-478, latest revision for Precast Reinforced Concrete Manhole sections. Tapered sections and transition sections, where required, shall be of eccentric cone design, having the same wall thickness and reinforcement as the cylindrical ring sections. Flat slab tops shall be required for very shallow manholes and where shown.or specified. Cast iron manhole covers and assemblies shall be cast into slab tops for access into manholes. Minimum compressive strength of concrete shall be 4,000 psi and the maximum permissible absorption shall be six and one-half (6.5) percent. Risers shall be reinforced with a single cage of .steel placed within the center one-third (1/3) of the wall. The tongue or the groove of the joint shall contain one (1) line of 07110-2 circumferential reinforcement equal in area to that in the barrel of the manhole riser. The minimum cross -sectional area of steel per linear foot shall be twelve one -hundredths (0.12) square inches for larger sizes. Precast manhole sections shall fit together readily and shall have a self-contained "O" ring rubber gasket conforming to ASTM C-443. The quality of materials, the process of manufacture, and the finished manhole sections shall be subject to inspection and approval by the Engineer and his inspector. The manhole sections shall be perpendicular to their longitudinal axis within the limits listed in ASTM C-478. 07110.4 MANHOLE FRAMES AND COVERS Casting for manhole frames and covers shall be tough, even grained, soft grey iron, free from burnt on sand and other injurious defects and conform to the requirements of ASTM A 48, latest revision Class 30. 07110.5 BRICK Brick for manholes and other structures shall conform to applicable requirements of ASTM Specification C 62, latest revision, Grade SW. 07110.6 CONCRETE Concrete for sewer structures shall consist of a mix of Portland cement, fine and coarse aggregate and water to produce concrete with a minimum compressive strength at twenty-eight (28) days of not less than 3,000 psi when tested according to ASTM Designation C-39 or C-42. Air Content (by volume) of the mix shall be between four (4) and eight (8) percent when placed. The consistency of the concrete shall be such as to allow it to be worked into place without segregation or excessive laitance. Slump shall be no more than four (4) inches. 07110.7 MORTAR Mortar for masonry in sewer structures shall be 1:2 cement sand mix, except that hydrated lime may be substituted for not more than ten (10%) percent by weight, of the cement. 07110-3 07110.8 FLEXIBLE COUPLINGS Whenever it becomes necessary to join sewer pipe lines of dissimilar materials or pipe sizes it shall be required to use a flexible coupling. The coupling shall be made of virgin poly vinyl chloride (PVC) shall not harden, and shall be impervious to all known soil conditions. The coupling shall provide a permanent leakproof seal approved by the Southern Building Code Congress and manufactured in accordance by Fernco Joint Sealer Company or an approved equal. I 07110-4 SECTION 07120 SANITARY SEWER (GRAVITY) PIPE INSTALLATION 07120.1 DESCRIPTION OF WORK The work covered under this section shall consist of furnishing all labor, equipment and services for the installation of gravity sanitary sewer lines as shown on the drawings and specified herein and in agreement with the General Conditions of these contract documents. 07120.2 HANDLING AND STORING MATERIALS The Contractor shall unload pipe so as to avoid deformation or other injury thereto. Pipe shall not be placed within pipe of a larger size and shall not be rolled or dragged over gravel or rock during handling. The Contractor shall store the pipe on sills above storm drainage level and deliver for laying after the trench is excavated. When any joint or section of pipe is damaged during transporting, unloading, handling, or storing, the undamaged portions of the joint or section may be used where partial lengths are needed, or, if damaged sufficiently, the Engineer will reject the joint or section as being unfit for installation. If any defective pipe is discovered after installation, it shall be removed and replaced with sound pipe or shall be repaired by the Contractor in an approved manner and at his own expense. 07120.3 PIPE ALIGNMENT AND GRADE The layout of gravity sanitary sewer lines and invert elevations at governing points are as shown on the drawings. The Contractor shall do all layout work for 'lines and grades from that information shown on the drawings or as furnished by the Engineer. When a laser beam instrument is used to set line and grade, the unit must be maintained in good working order, and the calibration checked daily for both alignment and percent grade. In the event the required accuracy of alignment and grade is not adhered to, the Engineer will prohibit the use of laser beams. 07120.4 PREPARATION OF PIPE FOUNDATION 07120-1 The pipe foundation shall be prepared to be uniformly firm and shall be true to the lines and grades as shown on the plans. The preparation of the pipe bedding shall be in accordance with the typical trench cross sections as shown on the drawings. Under no circumstances shall pipe be laid in water, on rock, or when trench conditions or weather is unsuitable for such work. Whenever the nature of the ground will permit, the excavations at the bottom of the trench shall have the shape and dimensions of the outside lower third of the circumference of the pipe, care being taken to secure a firm bearing support uniformly throughout the length of the pipe. A space shall be excavated under and around each bell to sufficient depth to relieve it of any load and to allow ample space for filling and ,finishing the joint. The pipe, when thus bedded firmly, shall be on the exact grade. In case the bed shaped in the bottom of the trench is too low, the pipe shall be completely removed from position, and earth of suitable quality shall be placed and thoroughly tamped to prepare a new foundation for the pipe. In no case shall the pipe be brought to grade by blocking up under the barrel or bell of same, but a new and uniform support must be provided for the full length of the pipe. Where rock or boulders are encountered in the bottom of the trench, the same shall be removed to such depth that no part of the pipe, when laid to grade, will be closer to the rock or boulders than ,six (6) inches. A suitably tamped and shaped foundation of approved material shall be placed to bring the bottom of.the trench to proper subgrade over rock or boulders. Where the foundation material is found to be of poor supporting value, the Engineer may make minor adjustment in the location of the pipe to provide a more suitable foundation. Where this is not practical, the foundation shall be conditioned by removing the existing foundation material by undercutting to the depth as directed by the Engineer, within the limits established on the plans, and backfilling with either an approved material secured from unclassified excavation or borrow excavation at the nearest accessible location along the project, or foundation conditioning material consisting of crushed stone -or gravel or a combination of sand an¢ crushed stone or gravel approved by the Engineer as being suitable for the purpose intended. The selection of the type of backfill material to be used for foundation conditioning will be made by the Engineer. The Contractor shall remove all or which may accumulate in the and no pipes shall be laid until 07120-2 water which may be encountered trenches by pumping or bailing the water has been removed from the trench. Water so removed from the trench must be disposed of in such a manner as not to cause injury to work completed or in progress. 07120.5 PIPE LAYING Pipe shall be laid with bell ends facing in the direction of pipe laying, unless directed otherwise by the Engineer. In all cases, pipe is to be installed in strict accordance with the manufacturer's recommendations and the contract material specifications. The Engineer may augment any manufacturer's installation recommendations if, in his opinion, it will best serve the interest of the Owner. Proper tools, implements, and facilities satisfactory to the Engineer shall be provided and used for the safe and convenient prosecution of pipe laying. All pipe and other materials used in the laying of pipe will be lowered into the trench piece by piece by means of suitable equipment in such a manner to prevent damage to the pipe, materials, to the protective coating on the pipe materials, and to provide a safe working condition to all personnel in the trench. Each piece of pipe being lowered into the trench shall be clean, sound and free from defects. It shall be laid on the prepared foundation, as specified elsewhere to produce a straight line on a uniform grade, each pipe being laid so as to form a smooth and straight inside flow line. Pipe shall be removed at any time if broken, injured or displaced in the process of laying same, or of backfilling the trench. When cutting short lengths of pipe, a pipe cutter as approved by the Engineer will be used and care will be taken to make the cut at right angles to the centerline of the pipe or on the exact skew as shown on the plans. In the case of push -on pipe, the cut ends shall be tapered with a portable grinder, or coarse file to match the manufactured taper. During times when pipe laying is not in progress, the open ends of pipe shall be closed and no trench water or other material shall be permitted to enter the pipe. Where the pipe is laid on a grade of ten (10)percent or greater, the laying shall start at the bottom of the slope and proceed upward with the bell end of the new pipe upgrade. All pipe laid on a grade of ten (10) percent or greater shall require thrust blocking and keying as shown on the drawings and standard details. Where pipe lines of different materials are joined together a 07120-3 r standard sewer repair coupling shall be used. The couplings shall be Eastern Standard Sewer Repair Couplings (Mission Rubber Company), the Fernco Joint Sealer Company or an equal product approved by the Engineer. 07120_6 BACRFILLING All backfill shall be compacted so as not to damage the pipe and appurtenances and shall be compacted to ninety-five (95) percent of the Standard Proctor Test for the various types of backfill materials. Methods of backfilling shall be in strict accordance with the pipe manufacturer's recommendations. All backfill materials shall have been approved by the Engineer. Select backfill material shall be used when requested by the Engineer. Select material shall be defined as a finely graded material free from stones over one-half (1/)2 inch in diameter, plastic clays, organic material, frozen lumps and various debris and shall be approved by the Engineer prior to its installation. Care shall be taken during backfill and compaction operations to maintain alignment and prevent damage to the joints. The backfill shall be kept free from stones, frozen lumps, chunks of highly plastic clay, or other objectional material. All pipe backfill areas shall be graded and maintained in such a condition that erosion or saturation will not damage the pipe bed or backfill. Heavy equipment shall not be operated over any pipe until it has been properly backfilled and has a minimum cover as required by the plans. Where any part of the required cover is above the proposed finish grade, the Contractor shall place, maintain, and finally remove such material at no cost to the Owner. Pipe which becomes mis-aligned, shows excessive settlement, or has been otherwise damaged by the Contractor's operations shall be removed and replaced by the Contractor at no cost to the Owner. The Contractor shall maintain all pipes installed in a condition that they will function continuously from the time the pipe is installed until the project is accepted. 07120.7 MEASUREMENT AND PAYMENT Quantities of pipe installed in accordance with the requirements of this section shall be verified in the field by the Engineer. Payment shall be made for total number of lineal feet of pipe installed at the unit prices 'bid in each depth category. Price 07120-4 and payment shall constitute full compensation for furnishing all equipment, tools, labor, and materials to complete the work as specified. 07120-5 r SECTION 07290 SANITARY SEWER MANHOLE MATERIAL, INSTALLATION & TESTING 07290.1 DESCRIPTION OF WORK The work covered under this section shall consist of furnishing all materials, labor, equipment, and services for the complete installation of sanitary sewer manholes. 07290.2 MANHOLE CONSTRUCTION Sanitary sewer manholes shall be installed at each break in line or grade in each sanitary sewer line as shown on the contract drawings. The manholes shall consist of precast reinforced concrete sections including a base section and conical top section. These precast concrete sections shall conform to ASTM C-478, latest revision. The minimum inside diameter of the manhole shall be five (5) feet unless noted otherwise on the drawings. Flat slab tops may be used in non -traffic areas, for very shallow manholes, or where shown on the drawings or approved by the Engineer. Maximum allowable absorption of concrete shall be eight (8) per cent. Minimum compressive strength of concrete for all sections shall be 4000 psi. Each precast concrete section shall be. joined together with a 110" ring rubber gasket conforming to ASTM C-443 or an approved sealant conforming to Federal Specification 55500210. Manhole inverts shall be constructed of concrete or concrete and brick of semicircular section conforming to the inside diameter of the outlet sewer. Changes in size of pipe or grade shall be made gradually and change in direction constructed by using true curves. Each manhole shall be provided with such channels for all connecting sewer pipes. 07290.3 MANHOLE INSTALLATION The manhole foundation shall be prepared so as to provide a firm, level area on which to place the precast concrete manhole base section. When poor foundation soil is encountered or excess groundwater exists the foundation shall be excavated twelve (12) inches below the final subgrade elevation backfilled with washed stone to provide a proper foundation. 07290-1 r The manhole sections l shall be lifted from the side of the excavation to the bottom of the trench with equipment and support slings capable of safely handling the heavy concrete pieces. The manhole shall be set plumb and adjusted to the final finished surface grade with brick and mortar. Pipe openings shall be exactly aligned to that of the pipe entering and leaving the manhole. The gravity sanitary sewer pipe lines shall be placed in the manhole openings, properly aligned, and set to grade. Sanitary sewer shall be connected to the manholes using lock joint flexible manhole sleeves or equal. For large diameter pipe where a flexible rubber sleeve is not available the pipe line shall be sealed into the manhole using an expanding type or non -shrink type grout. Manhole steps shall be properly spaced as shown in the standard detail drawing, but in no case more than fifteen (15) inches on center. The steps shall be made of heavy cast iron (10 inch thick), reinforced plastic (ASTM 2146-Type II.), or aluminum (min. load 1000 lbs.). 07290.4 MANHOLE FRAMES AND COVERS Frames and covers shall be cast iron of superior quality, tough and even texture. Castings shall be gray iron conforming to ASTM A-481 size as indicated, free from blow holes, porosity, hard spots, shrinkage distortion, or other defects, well cleaned and coated with asphalt paint. This paint shall result in a smooth coating, tough and tenacious when cold, not tacky and not brittle. The bearing surface between frame and cover, shall be machined to prevent rocking and rattling. The, standard manhole casting shall be designed for heavy duty use with a 210 pound frame and 130 pound cover. Acceptable products include Sumter Machinery Company (#MC-18.& MF-11), Dewey Brothers Foundry (#MHRCR-2001) or an approved equal. Special waterproof manhole frame and covers shall be installed only at those locations indicated on the contract drawings. Acceptable products include Neenah Foundry, Sumter Machinery Co.., Dewey Brothers Foundry, or an approved equal. The frame and cover shall be properly set in a bed of mortar and aligned to fit the top section of the manhole. Concrete brick, set in mortar, shall be used to adjust the top of the frame and cover to finished grade; however, no more than four (4) courses of brick will be used for adjustment. 07290-2 Yi , 07290.5 MANHOLE INVERTS Manhole inverts and benches shall be constructed in accordance with the standard details shown on the drawings. Invert shall be a U-shaped channel with a height of eight -tenths (0.8) of the diameter and be a smooth continuation of the pipe. The benches shall be constructed with a slope of one (1) inch per foot to the channel. The channel and invert shall be constructed with a minimum of 2000 psi concrete or brick fill with concrete finish minimum one (1) inch thick. Where sewer changes directions at the manhole, channel shall be constructed with a smooth curve with as large a radius as the diameter of the manhole will allow. 07290.6 MANHOLE DROPS Standard drop manholes will be constructed only at those locations shown on the drawings or as approved by the engineer. The design of the drop connection shall be in accordance with the standard detail drawing. The cost of the extra pipe, labor, etc. required to construct a drop manhole will be included in the unit price for the drop manhole at the depths listed. 07290.7 INSPECTION AND ACCEPTANCE Manholes shall be constructed to provide a true circular inside diameter with properly corbeled tops, satisfactory inverts and properly placed steps and castings. Any visible leaks in the manholes shall be completely stopped to the satisfaction of the Engineer. 07290.8 MANHOLE VENTS Where designated on the contract drawings, a four (4) inch diameter vent pipe shall be installed as an integral part of the manhole. The vent pipe is to be tapped in to the upper most section of the manhole, anchored in concrete and extended vertically to the elevation shown on the drawings. The pipe shall have a reverse bend and screen to prohibit rain and foreign materials from entering pipe. The pipe material shall be Schedule 40 Galvanized Steel with two coats of epoxy paint approved by the Engineer. 07290-3 0.7290.9 MEASUREi+WNT AND PAYMENT Quantities of manholes installed in accordance with the requirements of this section shall be verified in the field by the Engineer. Payment shall be made for Standard Manholes or Standard Drop Manholes at the prescribed depth measured from the top of the frame to the low pipe invert at the respective unit price bid. Payments for watertight manhole frame and covers and manhole vents will be considered to be included in the unit price bids for the respective manholes. Payment shall constitute full compensation for furnishing all equipment, tools, labor and incidentals and performance of all work necessary to install the manholes as specified. U 07290-4 SECTION 07295 SANITARY SEWER SERVICE CONNECTIONS 07295.1 DESCRIPTION OF WORK The work covered under this section shall consist of furnishing all materials, labor, equipment, and services for the complete installation of a sanitary sewer service connection from the sanitary sewer (gravity) main line to the edge of the property to be served as,shown on the project drawings. 07295.2 CONNECTION TO MAIN The standard sewer service connection shall be four (4) inches in diameter unless shown otherwise on the drawings, and shall connect to the main at a "wye" branch connection installed with the pipeline as it is being laid. The "wye" branch shall be of the same material as the main pipe line. Direct taps into the sewer main will not be acceptable unless approved by the Engineer prior to the laying of the main line. 07295.3 CONNECTION TO MANHOLE When shown on the drawings or directed by the Engineer, a sewer service connection shall be made into a manhole. The connection shall be made at the manhole invert. The invert shall be rebuilt so as to provide a smooth transition from service connection to main line. Inverts and benches shall be constructed in such a way as to prevent the deposition of solids in the manhole. 07295.4 SERVICE LINE The service line shall be installed from the "wye" branch connection to the edge of the public or utility right-of-way as shown on the plans. The sewer service line will be constructed of either PVC pipe (PVC schedule 40) pipe, or Ductile Iron (CL 350) as shown on the plans. When the service, line pipe material is different from that of the main line a flexible, water tight, rubber transition coupling shall be used to join the service line to the "wye" connection. The service line shall be laid at a minimum grade of one (1.0) percent with a minimum cover of three (3.0) feet. Less than three (3) feet of cover will require the use of ductile iron pipe. 07295-1 07295.5 CLEANOUT AND PLUG At the edge of the public or utility right-of-way a "cleanout" shall be installed. The cleanout shall consist of a "wye" branch connection, forty-five (45) degree bend, riser pipe, and threaded plug installed flush with finished ground elevation. The end of the utility owner's sewer service connection shall terminate at the end of the pipe which will normally extend five (5) feet beyond the "wye" branch for the cleanout. A watertight plug shall be installed at the end of this line until such time as the property owner directs the utility owner to connect his facilities to the sewer system. 07295.6 MEASUREMENT AND PAYMENT Payment for the -furnishing and installation of all service connections ("wye" branches, service line, clean outs, plugs, couplings, etc.) as described in this section and as shown on the plans, shall be covered under the contract unit price bid for each Sewer Service Connection. CL 07295-2 SECTION 07412 BORE AND ENCASEMENT 07412.1 DESCRIPTION OF WORK The work under this section consists of furnishing all materials, labor, equipment and services required for the complete installation of encasement pipe and carrier pipes under highways and railroads by boring and jacking as shown on the drawings and specified herein. All work in connection with constructing encasement pipes under highways and railroads shall comply with all current requirements of governing highway and railroad Agencies. The Contractor shall be familiar with these requirements. 07412.2 ENCASEMENT MATERIALS Encasement pipe shall be smooth ASTM Designation A139, Grade B. coated in accordance with AWWA thickness shall be as follows: Pipe -Nominal Diameter Inches. 16 20 24 30 36 07412.3 INSTALLATION OF ENCASEMENT wall welded steel conforming to The outside of the pipe shall be Standard C203. Minimum pipe wall Wall Thickness Inches .250 .250 .250 .312 .500 Encasements shall be installed by boring and jacking unless field conditions require otherwise. It shall be the Contractor's responsibility to notify the Engineer immediately if conditions not permit a jack and bore installation. The encasement pipe shall be of the diameter indicated for the carrier pipe as shown on the drawing. Installation of encasement pipe shall include all related work and services such as mobilization of equipment, constructing and maintaining working pits, right-of-way maintenance and restoration, traffic maintenance, mining, excavations, dewatering, 07412-1 sheeting, shoring and bracing for embankments, operating pits, and as elsewhere required shall be placed and maintained in order that work may proceed safely and expeditiously. The alignment and grade shall be carefully maintained and the encasement pipe installed in a straight line. The space outside the encasement and the ground shall be filled with grout, sand or pea gravel, as directed by the Engineer. The Engineer will direct that this space be filled if the space is large enough to cause any earth settling. Before the pipe is installed in the casing, pressure creosoted wood blocks shall be rigidly fastened to the barrel of the pipe. After completion of the casing, the Contractor shall insert the pipeline in pre -jointed segments. No contact will be permitted between the casing and the carrier pipeline. 07412.4 MEASUREMENT AND PAYMENT Quantities of encasement pipe installed by the boring and jacking method shall be determined by measuring the actual lineal feet of encasement pipe in the ground. Payment shall be for the total number of lineal feet of encasement pipe installed at the respective unit price bid for the item: Price and payment shall constitute full compensation for furnishing all equipment, labor, tools, and materials to complete all of the work required under.this section including excavation of working pits, encasement pipe, carrier pipe, dewatering, shoring, etc. m 07412-2 pppppw- r of North Carolina Department of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Secretary Kerr T. Stevens, Director Division of Water Quality WATER QUALITY SECTION January 17, 2001 Mr. Ezra W. Allman Director of Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793 Dear Mr. Allman: AM RCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES SUBJECT: Permit No. WQ0019424 City of Hendersonville Hamilton's Landing Wastewater Collection System Extension '\�pnderson County a In accordance with your application received December 12, 2000, please find attached Permit No. WQ0019424 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 1 5A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .p200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted ,February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North, Carol i na-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. Ezra W. Allman Page Two January 17, 2001 In accordance.with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 559 linear feet of eight inch gravity sewer.to serve fifteen (15) homes as part of the Hamilton's Landing sewage collection system, and the discharge of approximately 5,4000 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received December 12, 2000, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request and adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. ` If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, Kerr T. Stevens xc: Henderson County Health Department Sam Laughter John Jeter Roy M. Davis NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT 'his permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall, be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stationsshall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, .including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be.taken to ensure that the problem does not recur. Permit issued this the 17th day of January, 2001 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION K6rr T. Stevens, DiWdlor Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0019424 Permit No. WQ0019424 January 17, 2001 Partial ENGINEERS CERTIFICATION Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, , for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date. The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 of North Carolina epartment of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor 'William G. Ross Jr., Secretary Gregory J. Thorpe, Ph D., Acting Director November 14, 20, City of Hendersonville Ezra Allman Post Office Box 1760 Hendersonville NC 28793 Subject: Permit No. WQ0019424 Hendersonville City -Hamilton Henderson County Dear Mr. Allman: The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will, be forwarded to the Asheville Regional Office and have not been reviewed. .If a review is conducted, you will be notified of any non- conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. Sincerely, J Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files Mountain Engineering 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50 % recycled/10% post -consumer paper o. WQ0019424 January 17, 2001 ENGINEER'S CERTIFICATION Partial xx Final REGc1`��,ry on. U,$vi1�`�}: 1 G :tL�j1Y I, .John B. Jeter .. , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Hamilton's Landing Hendersonville, Henderson Co. for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such -that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date The Division of Water Quality hereby acknowledges receipt and acceptance of this Engineers n Certification p The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion. of this Engineer's Certification shall be considered a. violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY - WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH,_ NORTH CAROLINA 27699-1617 MOUNTAIN ENGINEERING COMPANY CIVIL ENGINEERING + SITE PLANNING P.O. Box 66 Flat Rock, N.C. 28731 (828) 697-9573 Mr. Kerr T. Stevens, Director N.C. Department of Environment and Natural Resources Division of Water Quality iPye�raiits�7andEngineeringUnit, Post Office Box 29535 Raleigh, North Carolina 27626-0535 Re: ilemiitNoU4 QQ019424 City of Hendersonville Hamilton's Landing Wastewater Collection System Extension Henderson County Dear Mr. Stevens: 15 October 2001 NOV 0 9 2001 DWQ STAFF SMVICES To the best of my knowledge, from periodic construction inspections and tests, Sewer System Improvements for Hamilton's Landing have been completed according to the approved plans, specifications, and permit. I recommend acceptance by the City of Hendersonville for connection to the municipal public sanitary sewer system. cc: City of Hendersonville Glade Holdings aaaaa�ac C ee� oaara. ARO 4,7 v �OOYi° `r s (5 so ln Jo R tlon-U`,soha�9c Peonit'un9 P. E. PPPPP""_ EFufNorth Carolina epartment of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director Division of Water Quality WATER QUALITY SECTION October 4, 2001 Mr. Ezra Allman, Director Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793-1760 Dear Mr. Allman: �46 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES SUBJECT: Permit No. WQ0020526 Charleston at the Meadows, Phase I City of Hendersonville Wastewater Collection System Extension ,Hendersonville County In accordance with your application received September 28, 2001, please find attached Permit No.WQ0020526 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 505 linear feet of eight (8) inch gravity sewer; to serve Charleston at the Meadows, Phase I as part of the City of Hendersonville's wastewater collection system and the discharge of approximately 9,360 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received September 28, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of* this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 8281251-6208. Sincerely, Thorpe, Ph.D.. Enclosure xc: Henderson County Health Department Non -Discharge Permitting Unit Paul Patterson Roy Davis wce-co aosa6 CITY OF HENDERSONVILLE COUNCIL .<u H. Niehoff, Jr. J. CRUTENDEN HARLEY Mayor, "The City of Four Seasons" Mary Jo Padgett LONDA MURRAY Mayor Pro-TernWATER AND SEWER DEPARTMENT Chris A. Carteerr- MARY JO PADGER City Manager Ezra Allman, Director Tammie K. Drake- BARBARA.VOLK' City: Clerk LETTER OF TRANSMITTAL Mr. Kim H. Colson, P.E., Supervisor September24, 2001 N. C. Department of Environment & Natural: Resources Division of Water Quality 161-7 Mail Service Center Raleigh, N.C. 27699-1617 This project is being forwarded to you for your review and approval.•' Submitted By:::z4m Al Ater an Sewer Department CITY OF HENDERSONVILLE _ r of SE 2 82001 61 D cc: Project File ;�,f AS FIErf fOlj QL i,S�`'1�t?h' 318 Fourth Avenue East P.O.. Box 1760 Phone: (828).697-3063 Hendersonville, NC 28792, Hendersonville, NC 28793 Fax: , (828)'697-1707 e-mail: eallman@cityofhendersonville.org . w .cityofhendersonville.org CITY OF HENDERSONVILLE _eo H. Niehoff, Jr. Mayor - The City of Four Seasons"' Many Jo Padgett - - Ms A. WATER AND SEWER DEPARTMENT Carter Chris A. Carter � City Manager ' . - Ezra Allman, Director - T=rnie K. Drake City Clerk - - Mr. Kim H. Colson, P.E., Supervisor N. C: Department of Environment & Natural Resources Division of Water Quality . 1,617 Mail Service Center Raleigh, N.C. 27699-1617 Re: CAPACITY ACCEPTANCE LETTER. Charleston at The Meadows, Phase I Sewer Line Extension., CITY COUNCIL: J. CRMENDEN HARLEY LONDA MURRAY MARY JO PADGM BARBARA VOLK September 24, 2001 Dear Mr. Colson: `� F This is to advise you.that I have reviewed the plans and specifications prepared by Mr. Robert Paul Patterson, P:E;, of Patterson & Patterson, of Hendersonville, N.C. for a proposed gravity sewer collection system to serve the referenced project. It is my opinion that the City of Hendersonville has the capacity to accept the additional wastewater flows that will be generated by this,project. This project is being 'submitted via Fast Track for your review and approval. If you have any questions, call me at (828) 697-3063. cc: Project.file, 318 Fourth Avenue East Hendersonville,.NC 28792 - e-mad:. eallman@cityofhendemonville.org Sincerely, E_ a Allman, irector ater and Sewer Department ' CITY OF HENDERSONVILLE P.O. Box 1760 - Phone: (828) 697-3063 Hendersonville,. NC 28793 Fax: (828)697-1707 va nv.cityofnendersonville.org c� •O THE WEAR GROUP, INC. 1002 RT. 4 BOX 227C HENDERSONVILLE, NC 28739 �Vv /��Q��Q� � �')i/ Q�� J-- M, (828) 674-3100 PAVd'�+'�'� DOLLARS I 66-7349-2531 DATE TO THE ORDER OF I CHECK NO Ne-DA) Q s//dooD 116011 p BINS RIDGE SAVINGS BANK /a � q MEMO 1:253173496s: 56 48009831I i002 State of North Carolina r!Dk., Department of Environment and Natural Resour es NP',Z l6 a, Division of Water Quality NON -DISCHARGE PERMIT APPLICATIO �lswl_ ,i`xil tp 1, GRAVITY SEWER COLLECTION SYSTEMS (Pump stations, force mains and pressure sewers are not to be included as part of this application package.) (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) INSTRUCTIONS: Please indicate that you have included the following list of application requirements by signing your initials in the @Q'sp/ace provided next to each item. ekA. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to the content of this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. Failure to submit all required items will lead to additional processing and review time for the permit application. B. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and hh' Natural Resources (NCDENR). C. Flow Acceptance Letters — If the owner of the W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the WWTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/W WTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. D. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been. received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. E. Operational Agreements — Submit one original and two copies of a properly executed Operational Agreement if the sewer extension will be serving residential or commercial lots (houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use Form HOA 10/99. If the applicant is a developer, use Form DEV 10/99. I. GENERAL INFORMATION: Application (to be completed by DWQ) 1. Applicant's name (name of the municipality, corporation, individual, etc.): City of Hendersonville 2. Owner's or signing official's name and title (15A NCAC 2H .0206(b)): Ezra Allman, Director 3. Name and complete address of applicant: City of Hendersonville City: Hendersonville State: NC Zip: 28793-1760 Telephone number: ( 828 ) 697-3063 Facsimile number: ( 828 ) 697-1707 4. Project name (name of the subdivision, facility or establishment, etc.): Charleston At The Meadows. Phase 1 FORM: GSPA 02/00 Page 1 of C 5. County where project is located: Henderson 6. Na Afro' d OJOVIe address of engineering firm: Patterson & Patterson Cit: Hendersonville State: _ Telephone number: ( 828 ) 692-6629 Zip: 28793-1189 Facsimile number: ( 828 ) 692-6629 7. Name and affiliation of contact person who can answer questions about application: Paul Patterson. P.E. or Sam Fore nn City of Hendersonville H. PERMIT INFORMATION: 1. Project is: X new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number and the issuance date 3. Applicant is: X public private. If private, units (lots, townhomes, etc.) are: leased (Skip to Section II1.) sold If sold, facilities owned by a: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) M. INFORMATION ON WASTEWATER: 1. Please provide a one- or two -word description specifying the origin of the wastewater (school, subdivision, hospital, commercial facility, industry, apartments, condominiums, etc.): Residential/Subdivision 2. Volume of wastewater generated by this project: 9,360 gallons per day 3. Explanation of how wastewater flow was determined (15A NCAC 2H .0219(I)): 6 condos w/3 bedrooms x 360 gpd + 30 condos w/2 bedrooms x 240 gpd/bedroom = 9,360 gpd 4. Nature of wastewater: 100 % Domestic/Commercial; % Industrial; % Other waste - specify: 5. If wastewater is industrial in nature: a. Level of pretreatment that has been provided to ensure protection of the receiving collection system and wastewater treatment facility: N/A b. If a pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: 1. Brief project description: Gravity sewer extension from existing manhole in alley to provide sewer service for project 2. Owner and name of wastewater treatment facility (W WTF) receiving wastewater (See Instruction C.): City of Hendersonville W WTF 3. WWTF permit number (NC00***** or W000*****): NCO025534 FORM: GSPA 02/00 Page 2 of 4 .. Aiary of GRAVITY SEWER to be permitted: Diameter (inches) Length (linear feet) 8" Ductile Iron CL350 30 8" SDR35 PVC 475 5. Does the subject gravity sewer collection system comply with the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200? X Yes; No. If no, please identify criteria and explain: IMPORTANT: If you responded No to question IV.S above, the completed application package, including two (2) copies of plans, specifications, supporting information and any other materials, should be submitted for an individual permit. The completed application package, including all supporting information and materials should be sent to the following address:' NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESO DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 NORTH SALISBURY STREET, RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 FORM: GSPA 02/00 Page 3 of 4 V. CERTIFICATIONS: Professional Engineer's Certification: I, Robert Paul Patterson. P.E. attest that this application for Charleston At The Meadows, Phase 1 has been reviewed by me and is accurate, complete and consistent with information supplied in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations and Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143- 215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification: I, Ezra Allman. Director attest that this application for Charleston At The Meadows, Phase 1 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: & tic, Date: 3 FORM: GSPA 02/00 Page 4 of 4 State of North Carolina Department of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director Division of Water Quality WATER QUALITY SECTION August 16, 2001 Mr. Ezra Allman, Director Hendersonville Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793-1760 Dear Mr. Allman: 1 i NCDENR NORTH C.AROLINA DEPARTMENT OF ENVIRONMENT AND. NATURAL RESOURCES SUBJECT: Permit No. WQ0020305 City of Hendersonville Creek Side -Phase II Wastewater Collection System Extension Henderson County In accordance with your application received August 13, 2001, please find attached Permit No.WQ0020305 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It tau mwppppp� ' ate of North Carolina Department of Environment and Natlirall Resource§ - -- Asheville Regional Office , Michael F. Easley, Governor William G. Ross, Jr., Secretary Kerr T. Stevens, Director Division of Water Quality WATER QUALITY SECTION June 18,.2001 Mr. Ezra W. Allman Director of Water and Sewer City of. Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28739 ME NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL, RFSOURCEs SUBJECT: Permit No. W00020007 City of Hendersonville Highland Lake, Phase 9 Wastewater Collection System Extension j Henderson County Dear Mr. Allman: - _-----_-'In=accordance withyourapplication-received on May 15;,2001—,p1easefind attached -Permit ---- Number WQ0020007 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. Ezra W. Allman June 18, 2001 Page'Two In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 1,200 linear feet of eight (8) inch Ductile Iron Pipe gravity sewer and approximately 2,268 linear feet of eight(8) inch diameter PVC gravity sewer; and the discharge of approximately 11,880 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received on May 15, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable;, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part, of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Roy M. Davis at 828/251-6208. Sinc ely, WWI _ Kerr T. Stevens Enclosure xc; Henderson County Health Department Non -Discharge Permitting Unit Freeland-Clinkscales & Assoc. Roy M. Davis NORTH CAROLINA ---�-- — — ENVIRONMENTAL- MANAGEMENT COMMISSION - DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permiee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters„ and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a,final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating- the -facilities constructed in the phase -being certified, shall -be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non - Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. A copy of the construction record drawings shall be maintained on fife by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 181h day of June, 2001. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION r 11,vwewvvl rr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number W00020007 Permit No. WQ0020007 June 18, 2001 - ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Highland Lake, Phase 9 Gravity Sewers, in Hendersonville. NC, Henderson County Project Name Location and County for the -Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date; The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 orth Carolina PW artme pPand nt of Environment t Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director NCDEN* R NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES November 14, 2000 " EZRA ALLMAN, DIRECTOR, WATER AND SEWER DEPARTMENT ,; - 1CITY OF = POST OFFIC OFFICE ILLE ���' IVOV l %ZOOO HENDERSONVILLE, NC 28793 - Subject: Permit No. W'Q0019.148 ,�Oy City of Hendersonville Lf Kay Thomas Drive Wastewater Collection System Extension Henderson County Dear Mr. Allman: In accordance with your application received October 9, 2000, we are forwarding herewith Permit No. WQ0019148, dated November 14, 2000, to the City of Hendersonville for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permtttee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as - constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute § 143-215.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to City of Hendersonville for the construction and operation of approximately 483 linear�feea of 8-inch gravity sewer to serve 12 three -bedroom units as part of the Kay Thomas Drive project, and the discharge of 4,320 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received October 9, 2000, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 715-6048 V An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper The sewage and wastewater collected by this system shall be treated in the City of Hendersonv- Wastewater Treatment Facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699- 6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Kristin E. Miguez at (919) 733-5083 extension 524. Sincerely, � err T. Stevens cc: Henderson County Health Department Asheville Regional_Office;-Water Quality Section (WWTF-Permit No. NC0025534) Laughter, Austin & Associates, PA NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 211.0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected at least three times per week until July 1, 2000; thereafter, pump stations shall be inspected at least daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCGO100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number (828) 251-6208, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the fourteenth day of November, 2000 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Kerr T. Stevens, Director UDivision of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0019148 Permit No. W00019148 November 14, 2000 ENGINEER'S CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 tate of North Carolina Department of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director Division of Water Quality WATER QUALITY SECTION November 5, 2001 Mr. Ezra W. Allman, Director Hendersonville Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793 SUBJECT: Permit No. WQ0020626 City of Hendersonville Highland Golf Villas Wastewater Collection System Extension Henderson County Dear Mr. Allman: In accordance with your application received on October 30, 2001, please find attached Permit No. WQ0020626 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. Ezra W. Allman November 5, 2001 Page Two In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 1,627 linear feet of eight (8) inch gravity sewer; a 28 gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and on site standby power; as well as approximately 1,475 linear feet of two (2) inch force main to serve Highland Golf Villas as part of the City of Hendersonville wastewater collection system and the discharge of 15,840 gallons per day of collected domestic wastewater into the existing City of Hendersonville sewerage system, pursuant to the application received on October 30, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into Mud Creek If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 67,14 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are madey this permit shall be final and binding. If you need additional information. concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, Gregory orpe, Ph.D. Enclosure xc: Henderson County Health Department Non -Discharge Permitting Unit Roy Davis John Jeter; Mountain Engineering NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If arN individual permit is not required, the following performance criteria shall be met 'as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being, certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A 11 NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage; etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 5t' day of November, 2001. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Gregory J. Thorpe, Ph.D�'Acting Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0020626 Permit No. WQ0020626 November 5, 2001 ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Highland Golf Villas, City of Hendersonville. Henderson County, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings' of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 D1 n- State of North Carolina 1 1 !. Department of Environment, Health and Natural Resources Ci 3 0 200l Division of Water Quality aci'7 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewer systems are not to be included as part of this application package) THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL , INSTRUCTIONS: Indicate that you have included the following list of required application package items by signing your initials in the space provided next to each item. Failure to submit all required items will lead to additional processing and review time/or the permit application. C A. Application Form -Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to item IV.6. and/or item IV.10. B. Attachment -Submit the completed and properly executed Form W SCA10/99 for each watershed within the project of-1 �tiop C. 0 Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Certificates of Public Convenience and Necessity - If the application is being submitted in the name of a privately - owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchisefor the area to he served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of aletter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area.is contiguous to art existing franchised area, and/or that franchise approval is expected. E. Operational Agreements -Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, -etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use Form HOA 10/99. If the applicant is a developer, use Form DEV 10/99. F. Flow Acceptance Letters - If the owner of the downstream Sewer and/or W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and W WTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/W WTF. The flow acceptance must not expire prior to permit issuance and must he dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not he accepted in lieu of a project -specific flow acceptance letter. THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 NORTH SALISBURY STREET, SUITE 1219 RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5093 FACSIMILE NUMBER: (919) 715-6048 For more information, visit our web site at: h2o.ennsurte.naus/ndpu/ Application Number: (to be completed by DWQ) FORM[: FTA 06/00 Page I of 5 H. GENERAL INFORMATION: 1. Applicant's name (name othe JnuDtc j2ali� co22rption� in dividual, etc.): 3. Name and 4. Project Name (name of the or establishment, etc.): 5. County where project is located: �S 6. Fee Submitted: 7. Name and complete address of City:l"ZtT/ /C Telephone Number: firm: (See Instruction State: A-C-1 Zip: /�) _ 3 Facsimile Number: 8. Name and affiliation of contact person who can answer questions about application: PERMIT INFORMATION: I. Project is: X new; modification. 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number 3. Applicant is —X public _ private. and the issue date If private, units (lots, townhomes, etc.) are: leased (Skip to item III);: sold If sold, facilities owned by a: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) 1. Please provide a one- or two -word description specifying the origin of the wastewater (school, �y subdivision, hospital, commercial facility, industry, apartments, condominiums, etc.): gF.5m 111 1 -AL 6ZIRDIVISMAI � �f 2. Volume of wastewater generated by this project: �,;'Y"� ao gallons per day. t /� 3. Explanation of how wastewater flow was determined (15A NCAC 2H .0219(1)): (4# X L360 jsW � 1�f�OL'7 cam) prorated at 5 days per week/7days and 10 months out of the year/12 months or 997zodl = 1322 GPD 4. Nature of Wastewater: 100 % Domestic/Commercial ; % Industrial ; % Other (specify) FORM: FTA 06100 Page 2 of 5 �. If wastew:uer is industrial in nature: a. Level of pretreatment has been provided to ensure protection of the receiving collection system and wastewater treatment facility: VA b If pretreatment permit is required, has one been issued? N/A Yes No. If yes, please attach a cop} ofthe pretreatment permit. Irno, provide date application was submitted IV. DESIGN INFORMATION: 1. Brief project description: '_. Owner and name of wastewater treatment facility (WWTF) receiving wastewater (See Instruction F.): 3. WWTF permit number (NC00'•"' or W000""'): AICVV2 4. List the owner(s) of any intermediate sewers if different from applicant or owner of WWTF (See Instruction F.) 5. Permit Number for sewers immediately downstream: 6. Summary of GRAVITY SEWER to be permitted: Diameter (in))chgcs) Length .({]ineaeyetl ___ 6. Does the subject gravity sewer collection system comply with the most recent version of the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200 ?_Yes No. If no, please identify criteria and explain 7. Summary of PUMP STATIONS to be permitted: No. or Name Design Flow (MGD) Pump Operational Pints GPM (a feet TDH Reliability. Option Selected +•' .i':= � ���� +. a tr-:, FORM: FTA 06/00 Page 3 of 5 S. Summary of FORCE MAIN to be permitted: Diameter (inches) Length I (linear feet) _ _ Lam_ .9. . List,any equipment being utilized that is ndt specifically mentioned elsewhere in the application or as part of the Minimum Design Criteria (e.g., telemetry, hoist, odor control equipment, mechanical bar screens, etc.): I (:%. ,� 10. Do the subject pump stations and force mains comply with the minimum Design Criteria for the Fast - Tract Permitting of Pump Stations and Force Mains documents adopted June 1, 2000 and 15A NCAC 2H .0200? —X Yes; No. If no,.please identify criteria and explain:. NOTE: If you responded NO to item IV.6. and/or item IVAO. above, two (2) copies of detailed plans, specifications, supporting information, and any other materials pertaining to the identified criteria should be submitted with the completed and appropriately executed application form. FORNI: FTA 06/00 Page 4 of 5 V. CERTIFICATIONS Professional Engineer's Certification: Certification: ^' L A' 1,���//t/ a L J(, attest that this application for l(�/7 /yD OIL has been reviewed by me and is accurate, complete and consistent with the information supplied in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and havejudged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly inakes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's Seal, Signature, and Date: Applicant's � Z IA Certification[ Pi N/5 UI L? /�S � , I, PA , attest that this application for fFA L4 [/J l has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation. or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature E r( AvK_ Date FORM: FTA 06/00 Page 5 of 5 Section GRINDER Page 109 =� Dated SEPTEMBER 1993 Performance Curve RPM: 3500 Discharge: Z" 225 .: 200 IMP .. impeller/volute combination. to factory for trim selections beyond 6.75'. - a®®®Ax ®®Refer 50 150 w 141 ®s ■tea®®®�®® ��►®�am��®oa®® : „ ■�=�®a®yam®�® ®��®sue®��a•®�®�® Operating point must fall within curve. Conditions of Service: G A r C9 G PUMP cN�` GPM: TDH: f 10 HYDROMATIC" PUMPS CITY- OF*HENDERSONVILLE �`�`°"""` Fred H. Niehoff,Jr. -. •• . ' - ' '` • J. CRrrrENDFN HARLE'Y Mayor •�,The Gity of Four Seasons„ - , Mary Jo Padgett LONDA MURRAY Mayor Pro -Tern WATER AND SEWERDEPARTMENT Chris A. Carter, - MARY JO PADGEIT City Manager Ezra Allman, Director Tammie K. Drake' BARBARA'VOLR City.Clerk October 26, 2001 Mr. Kim H-- Colson, .P.E., Supervisor N. C. Department, of Environment &Natural Resources, Division of Water Quality 1,617''Mail Service Center - Raleigh, N.C. 27699-1617 Re: CAPACITY ACCEPTANCE'LETTER- Highland Golf Villas { Sewer -Line Extension; Dear Mr. Colson: This is to advise you that I have reviewed the'plans,and'specifications prepared by. Mr. John Baker Jeter, IT, P.E.,; of Mountain Engineering Company of. Hendersonville, N.C. for a proposed 2" Force Main, a,' :-Sewer Lift, Station and an 8" Gravity Sewer Collection System'to serve the referenced project. It is my -opinion that -the City.of Hendersonville has the'capacity to accept the additional wastewater flows, that will be generated by this project. f This: project is being submitted via Fast Track.for your review and"approval. If -you have any questions; call rile at (828):697-3063, ---'Sincerely, G [ 1] EZA Allman, Director - --� - Water and Sewer Department OCT 3 0 200, ` CITY OF HENDERSONVILLE = l'JAiEI� ppL C )' IISHEVIL%LF(�E 117 $L 01pCE - cc•'Project f le • 318 Fourth Avenue East P.O.. Box 1760 - Phone: (828) 697-3063 Hendersonville; NC 28792' Hendersonvitle, NC 287913 - ' Fax: '(828)'697-1707 e-mail: eallman@cityofhendem6nville.org' - wivw.cityothendersonville.org CITY OF HENDERSONVILLE Fred H. Niehoff, Jr. Mayor "The City of Four Seasons" Mary Jo Padgett Mayor Pro WATER AND SEWER DEPARTMENT Chris A. Carterer - City Manager Ezra Allman, Director Tammie K. Drake City Clerk LETTER OF TRANSMITTAL Mr. Kim H. Colson, P.E., Supervisor N. C. Department of Enviromnent & Natural Resources Division of Water Quality 1617 Mail Service Center Raleigh, N.C. 27699-1617 This project is being foiwarded to you for your review and approval. CITY COUNCIL: J. CRrrrENDEN HARLEY LONDA MURRAY MARY JO PADGM BARBARA VOLK October 26, 2001 Submitted By: ZL Water. and Sewer Department CITY OF HENDERSONVILLE cc: Project File 318 Fourth Avenue Fast P.O. Box 1760. Phone: (828) 697-3063 Hendersonville, NC 28792 ' Hendersonville, NC 28793 Fax: (828)697-1707 e-mail: eallman@cityofhendemonville.org vnvw.cityofhendersonville.org PE HOLDINGS, INC. 1822 . INVOICE NO. DESCRIPTION INVOICEAMOUNT DEDUCTION BALANCE '20/01 92001 GLA-Highland Lake sewer 400.00 .00 400.00 ;KD 9/20/01 E CHECK NUMBER D 1822 TOTALS D 400.00 .00 400.00 GLADE HOLDINGS, INC. 443 N. MAIN STREET, SUITE 10 HENDERSONVILLE, NC 28792 B1JlXT NORTH CAROLINA 66-112/631 • I 1822 j .y*****************************************Four'hundred dollars and no cents DATE 9/20/01 TOTHE NC Dept. Environ.&Natural Res. ORDER OF 11.00182211' i:0531011211:51945332430 CHECK NO. AMOUNT 1822 $******400.00 CITY OF HENDERSONVILLE WATER & SEWER DEPARTMENT HENDERSONVILLE NORTH CAROLINA TECHNICAL SPECIFICATIONS FOR HIGHLAND GOLF VILLAS U] SANITARY SEWER IMPROVEMENTS Prepared by: THE CITY OF HENDERSONVILLE Water & Sewer Department Engineering Division 318 Fourth Avenue East P.O. Box 1760 Hendersonville, NC 28793 v 3 0 2001 Telephone No. (704)697-3065 FAX No. (704) 697-1707 SECTION 07110 SEWER PIPE (GRAVITY) AND APPURTENANCE MATERIAL 07110.1 SCOPE These specifications shall furnished and ins_alled to installations in accordance appurtenances shall be of the plans and designated herein. 07110.2 GENERAL apply to the materials to be complete the sanitary sewer line with the plans. All pipe and class and type as indicated on the All materials shall be first quality with smooth interior and exterior surfaces, free from cracks, blisters, honeycombs and other imperfections, and true to theoretical shapes and forms throughout. All materials shall be subject to the inspection of the Engineer at the plant, trench, or other point of delivery, for the purpose of culling and rejecting materials, which does not conform to the requirements of these specifications. Such material shall be marked by the Engineer and the Contractor shall remove it from the project site upon notice being received of its rejection. As particular specifications are cited, the designation shall be construed to refer to the latest revision under the same specification number, or to superseding specifications under a new number except provisions in revised specifications which are clearly inapplicable. Polyvinyl Chloride Pipe Polyvinyl Chloride (PVC) pipe shall meet the requirement of ASTM D 3034, latest edition, and be suitable for use as a gravity sewer conduit. The standard dimension ratio (SDR) shall be thirty-five (35) unless otherwise specified. The pipe shall be supplied in standard laying lengths of twenty (20) feet and twelve and one-half (12.5) feet. All PVC pipe joints shall be of an integral bell and spigot of the same material as the pipe with a solid cross-section rubber 110" ring securely locked in place at the point of manufacture. Service saddles and other fittings shall be supplied by the pipe manufacturer and shall be of the same material and type of construction as the pipe material. 07110-1 07110.3 Ductile Iron Pipe Ductile Iron Pipe shall be manufactured in accordance with ANSI Specification A 21.51. All Ductile Iron Pipe shall be Class 50 unless otherwise specified and shall be lined with cement mortar not less than one sixteenth (1/16) inch thick conforming to ANSI Specification A 21.4. Slip or "push -on" joints shall be manufactured in accordance with ANSI Specification_ A 21.11. Bells of "slip" joint pipe shall be contoured to receive a bulbshaped, circular rubber gasket, and plain ends shall have a slight taper to facilitate installation. The lubricant used in making up the joints shall be furnished by the pipe manufacturer. The jointing shall be done by guiding the plain end into the bell until contact is made with the gasket and by exerting a sufficient compressive force to drive the joint home until plain end makes full contact with the base of the bell. Steel Casing Pipe Steel casing shall conform to ASTM A-53, Grade B or ASTM A-139 Grade B standard specifications. Casing pipe shall have a wall thickness as follows, unless otherwise noted in the bid documents: 12" thru 24" casing - 0.250 inches wall thickness 30" casing - 0.312 inches wall thickness 36" casing - 0.375 inches wall thickness MANHOLES Precast concrete manhole bases, risers and cones shall conform to ASTM C-478, latest revision for Precast Reinforced Concrete Manhole sections. Tapered sections and transition sections, where required, shall be of eccentric cone design, having the same wall thickness and reinforcement as the cylindrical ring sections. Flat slab tops shall be required for very shallow manholes and where shown or specified. Cast iron manhole covers and assemblies shall be cast into slab tops for access into manholes. Minimum compressive strength of concrete shall be 4,000 psi and the maximum permissible absorption shall be six and one-half (6.5) percent. Risers shall be reinforced with a single cage of steel placed within the center one-third (1/3) of the wall. The tongue or the groove of the joint shall contain one (1) line of circumferential reinforcement equal in area to that in the barrel of the manhole riser. 07110-2 The minimum cross-secticnal area of steel per linear foot shall be twelve one -hundredths (0.12) square inches for larger sizes. Precast manhole sections shall fit together readily and shall have a self-contained "O" ring rubber gasket conforming to ASTM C-443. The quality of materials, the process of manufacture, and the finished manhole sections shall be subject to inspection and approval by the Engineer and his inspector. The manhole sections shall be perpendicular to their longitudinal axis within the limits listed in ASTM C-478. 07110.4 MANHOLE FRAMES AND COVERS Casting for manhole frames and covers shall be tough, even grained, soft grey iron, free from burnt on sand and other injurious defects and conform to the requirements of ASTM A 48, latest revision Class 30. 07110.5 BRICK Brick for manholes and other structures shall conform to applicable requirements of ASTM Specification C 62, latest revision, Grade SSA. 07110.6 CONCRETE Concrete for sewer structures shall consist of a mix of Portland cement, fine and coarse aggregate and water to produce concrete with a minimum compressive strength at twenty-eight (28) days of not less than 3,000 psi when tested according to ASTM Designation C-39 or C-42. Air Content (by volume) of the mix shall be between four (4) and eight (8) percent when placed. The consistency of the concrete shall be such as to allow it to be worked into place without segregation or excessive laitance. Slump shall be no more than four (4) inches. 07110.7 MORTAR Mortar for masonry in sewer structures shall be 1:2 cement sand mix, except that hydrated lime may be substituted for not more than ten (10%) percent by weight, of the cement. 07110-3 07110.8 FLEXIBLE COUPLINGS Whenever it becomes necessary to join sewer pipe lines of dissimilar materials or pipe sizes it shall be required to use a flexible coupling. The coupling shall be made of virgin poly vinyl chloride (PVC) shall not harden, and shall be impervious to all known soil conditions. The coupling shall provide a permanent leakproof seal approved by the Southern Building Code Congress and manufactured in accordance by Fernco Joint Sealer Company or an approved equal. 07110-4 SECTION 07120 SANITARY SEWER (GRAVITY) PIPE INSTALLATION 07120.1 DESCRIPTION OF WORK The work covered under this section shall consist of furnishing all labor, equipment and services for the installation of gravity sanitary sewer lines as shown on the drawings and specified herein and in agreement with the General Conditions of these contract documents. 07120.2 HANDLING AND STORING MATERIALS The Contractor shall unload pipe so as to avoid deformation or other injury thereto. Pipe shall not be placed within pipe of a larger size and shall not be rolled or dragged over gravel or rock during handling. The Contractor shall store the pipe on sills above storm drainage level and deliver for laying after the trench is excavated. When any joint or section of pipe is damaged during transporting, unloading, handling, or storing, the undamaged portions of the joint or section may be used where partial lengths are needed, or, if damaged sufficiently, the Engineer will reject the joint or section as being unfit for installation. If any defective pipe is discovered after installation, it shall be removed and replaced with sound pipe or shall be repaired by the Contractor in an approved manner and at his own expense. 07120.3 PIPE ALIGNMENT AND GRADE The layout of gravity sanitary sewer lines and invert elevations at governing points are as shown on the drawings. The Contractor shall do all layout work for lines and grades from that information shown on the drawings or as furnished by the Engineer. When a laser beam instrument is used to set line and grade, the unit must be maintained in good working order, and the calibration checked daily for both alignment and percent grade. In the event the required accuracy of alignment and grade is not adhered to, the Engineer will prohibit the use of laser beams. 07120.4 PREPARATION OF PIPE FOUNDATION The pipe foundation shall be prepared to be uniformly firm and shall be true to the lines and grades as shown_ on the plans. The preparation of the pipe bedding shall be in accordance with the typical trench cross sections as shown on the drawings. 07120-1 Under no circumstances shall pipe be laid in water, on rock, or when trench conditions or weather is unsuitable for such work. Whenever the nature of the ground will permit, the excavations at the bottom of the trench shall have the shape and dimensions of the outside lower third of the circumference of the pipe, care being taken to secure a firm bearing support uniformly throughout the length of the pipe. A space shall be excavated under and around each bell to sufficient depth to relieve it of any load and to allow ample space for filling and finishing the joint. The pipe, when thus bedded firmly, shall be on the exact grade. In case the bed shaped in the bottom of the trench is too low, the pipe shall be completely removed from position, and earth of suitable quality shall be placed and thoroughly tamped to prepare a new foundation for the pipe. In no case shall the pipe be brought to grade by blocking up under the barrel or bell of same, but a new and uniform support must be provided for the full length of the pipe. Where rock or boulders are encountered in the bottom of the trench, the same shall be removed to such depth that no part of the pipe, when laid to grade, will be closer to the rock or boulders than six (6) inches. A suitably tamped and shaped foundation of approved material shall be placed to bring the bottom of the trench to proper subgrade over rock or boulders. Where the foundation material is found to be of poor supporting value, the Engineer may make minor adjustment in the location of the pipe to provide a more suitable foundation. Where this is not practical, the foundation shall be conditioned by removing the existing foundation material by undercutting to the depth as directed by the Engineer, within the limits established on the plans, and backfilling w'_th either an approved material secured from unclassified excavation or borrow excavation at the nearest accessible location along .the project, or foundation conditioning material consisting of crushed stone or gravel or a combination of sand and crushed stone or gravel approved by the Engineer as being suitable for the purpose intended. The selection of the type of backfill material to be used for foundation conditioning will be made by the Engineer. The Contractor shall remove all water which may be encountered or which may accumulate in the trenches by pumping or bailing and no pipes shall be laid until the water has been removed from the trench. Water so removed from the trench must be disposed of in such a manner as not to cause injury to work completed or in progress. 07120-2 07120.5 PIPE LAYING Pipe shall be laid with bell ends facing in the direction of pipe laying, unless directed otherwise by the Engineer. In all cases, pipe is to be installed in strict accordance with the manufacturer's r=_commer_dations and the contract material specifications. The Engineer may augmer_= any manufacturer's installation recommendations if, in his opinion, it will best serve the interest of the Owner. Proper tools, implements, and facilities satisfactory to the Engineer shall be provided and used for the safe and convenient prosecution of pipe laying. All pipe and other materials used in the laying of pipe will be lowered into the trench piece by piece by means of suitable equipment in such a manner to prevent damage to the pipe, materials, to the protective coating on the pipe materials, and to provide a safe working condition to all personnel in the trench. Each piece of pipe being lowered into the trench shall be clean, sound and free from defects. It shall be laid on the prepared foundation, as specified elsewhere to produce a straight line on a uniform grade, each pipe being laid so as to form a smooth and straight inside flow line. Pipe shall be removed at any time if broken, injured or displaced in the process of laying same, or of backfilling the trench. When cutting short lengths of pipe, a pipe cutter as approved by the Engineer will be used and care will be taken to make the cut at right angles to the centerline of the pipe or on the exact skew as shown on the plans. In the case of push -on pipe, the cut ends shall be tapered with a portable grinder, or'coarse file to match the manufactured taper. During times when pipe laying is not in progress, the open ends of pipe shall be closed and no trench water or other material shall be permitted to enter the pipe. Where the pipe is laid on a grade of ten (10) percent or greater, the laying shall start at the bottom of the slope and proceed upward with the bell end of the new pipe upgrade. All pipe laid on a grade of ten (10) percent or greater shall require thrust blocking and keying as shown on the drawings and standard details. Where pipe lines of different materials are joined together a standard sewer repair coupling shall be used. The couplings shall be Eastern Standard Sewer Repair Couplings (Mission Rubber Company), the Fernco Joint Sealer Compar__: or an equal product approved by the Engineer. 07120-3 07120.6 BACKFILLING All backfill shall be corpacted so as not =o damage the pipe and appurtenances and shall be compacted to ninety-five (95) percent of the Standard Proctor Test for the various types of backfill materials. Methods of backfilling shall be in stric= accordance with the pipe manufacturer's recommendations. All backfill materials shall have been approved by the Engineer. Select backfill material shall be used when requested by the Engineer. Select material shall be defined as a finely graded material free from stones over one-half (1/)2 inch in diameter, plastic clays, organic material, frozen lumps and various debris and shall be approved by the Engineer prior to its installation. Care shall be taken during backfill and corroaction operations to maintain alignment and prevent damage to the joints. The backfill shall be kept free from stones, frozen lumps, chunks of highly plastic clay, or other objectional material. All pipe backfill areas shall be graded and maintained in such a condition that erosion or saturation will not damage the pipe bed or backfill. Heavy equipment shall not be operated over any pipe until it has been properly backfilled and has a minimum cover as required by the plans. Where any part of the required cover is above the proposed finish grade, the Contractor shall place, maintain, and finally remove such material at no cost to the Owner. Pipe which becomes mis-aligned, shows excessive settlement, or has been otherwise damaged by the Contractor's operations shall be removed and replaced by the Contractor at no cost to the Owner. The Contractor shall maintain all pipes installed in a condition that they will function continuously from the time the pipe is installed until the project is accepted_ 07120.7 MEASUREMENT AND PAYMENT Quantities of pipe installed in accordance with the requirements of this section shall be verified in the field by the Engineer. Payment shall be made for total number of lineal feet of pipe installed at the unit prices bid in each depth category. Price and payment shall constitute full compensation for furnishing all equipment, tools, labor, and materials to complete the work as specified. 07120-4 SECTION 07290 SANITARY SEWER MANHOLE MATERIAL, INSTALLATION & TESTING 07290.1 DESCRIPTION OF WORK The work covered under this section shall consist of furnishing all materials, labor, equipment, and services for the complete installation of sanitary sewer manholes. 07290.2 MANHOLE CONSTRUCTION Sanitary sewer manholes shall be installed at each break in line or grade in each sanitary sewer line as shown on the contract drawings. The manholes shall consist of precast reinforced concrete sections including a base section and conical top section. These precast concrete sections shall conform to ASTM C-478, latest revision. The minimum inside diameter of the manhole shall be five (5) feet unless noted otherwise on the drawings. Flat slab tops may be used in non -traffic areas, for very shallow manholes, or where shown on the drawings or approved by the Engineer. Maximum allowable absorption of concrete shall be eight (8) per cent. Minimum comoressive strength of concrete for all sections shall be 4000 psi. Each precast concrete section shall be joined together with a "0" ring rubber gasket conforming to ASTM C-443 or an approved sealant conforming to Federal Specification 55500210. Manhole inverts shall be constructed of concrete or concrete and brick of.semicircular section conforming to the inside diameter of the outlet sewer. Changes in size of pipe or grade shall be made gradually and change in direction constructed by using true curves. Each manhole shall be provided with such channels for all connecting sewer pipes. 07290.3 MANHOLE INSTALLATION The manhole foundation shall be prepared so as to provide a firm, level area on which to place the precast concrete manhole base section. When poor foundation soil is encountered or excess groundwater exists the foundation shall be excavated twelve (12) inches below the final subgrade elevation backfilled with washed stone to provide a proper foundation. 07290-1 The manhole sections shall be lifted from the side of the excavation to the bottom of the trench wi_h equipment and support slings ca:able of safely handling the heavy concrete pieces. The manhole shall be set plumb and adjusted to the final finished surface grade with brick and mortar. Pipe openings sha'_1 be exactly aligned to that of the pipe entering and leaving the manhole. The gravity sanitary sewer pipe lines shall be placed in the manhole openings, properly aligned, and set to grade. Sanitary sewer shall be connected to the manholes using lock joint flexible manhole sleeves or equal. For large diameter pipe where a flexible rubber sleeve is not available the pipe line shall be sealed into the manhole using an expanding type or non -shrink type grout. Manhole steps shall be properly spaced as shown in the standard detail drawing, but in no case more than fifteen (15) inches on center. The steps shall be made of heavy cast iron (10 inch thick), reinforced plastic (ASTM 2146-Type II), or aluminum (min. load 1000 lbs.). 07290.4 MANHOLE FRAMES AND COVERS Frames and covers shall be cast iron of superior quality, tough and even texture. Castings shall be gray iron conforming to ASTM A-48, size as indicated, free from blow holes, porosity, hard spots, shrinkage distortion, or other defects, well cleaned and coated with asphalt paint. This paint shall result in a smooth coating, tough and tenacious when cold, not tacky and not brittle. The bearing surface between frame and cover shall be machined to prevent rocking and rattling. The standard manhole casting shall be designed for heavy duty use with a 210 pound frame and 130 pound cover. Acceptable products include Sumter Machinery Company (#MC-18 & ME-11), Dewey Brothers Foundry (#MHRCR-2001) or an approved equal. Special waterproof manhole frame and covers shall be installed only at those locations indicated on the contract drawings. Acceptable products include Neenah Foundry, Sumter Machinery Co., Dewey Brothers Foundry, or an approved equal. The frame and cover shall be properly set in a bed of mortar and aligned to fit the top section of the manhole. Concrete brick, set in mortar, shall be used to adjust the top of the frame and cover to finished grade; however, no more than four (4) courses of brick will be used for adjustment. 07290-2 7290.5 MANHOLE INVERTS Manhole inverts and benches shall be cons=ructed in accordance with the standard details shown on the drawings. Invert shall be a U-shaped channel with a height of eight -tenths (0.8) of the diameter and be a smooth continuation_ of the pipe. The benches shall be constructed with a slope of one (1) inch per foot to the channel. The channel and invert shall be constructed with a minimum of 2000 psi concrete or brick fill with concrete finish minimum one (1) inch thick. Where sewer changes directions at the manhole, channel shall be constructed with a smooth curve with as large a radius as the diameter of the manhole will allow. 07290.6 MANHOLE DROPS Standard drop manholes will be constructed only at those locations shown on the drawings or as approved by the engineer. The design of the drop connection shall be in accordance with the standard detail drawing. The cost of the extra pipe, labor, etc. required to construct a drop manhole will be included in the unit price for the drop manhole at the depths listed. 07290.7 INSPECTION AND ACCEPTANCE Manholes shall be constructed to provide a true circular inside diameter with properly corbeled tops, satisfactory inverts and properly placed steps and castings. Any visible leaks in the manholes shall be completely stopped to the satisfaction of the Engineer. 07290.8 MANHOLE VENTS Where designated on the contract drawings, a four (4) inch diameter vent pipe shall be installed as an integral part of the manhole. The vent pipe is to be tapped in to the upper most section of the manhole, anchored in concrete and extended vertically to the elevation shown on the drawings. The pipe. shall have a reverse bend and screen to prohibit rain and foreign materials from entering pipe. The pipe material shall be Schedule 40 Galvanized Steel with two coats of epoxy paint approved by the Engineer. 07290-3 07290.9 MEASUREMENT AND PAYbIENT Quantities of manholes installed in accordance with the requirements of this section shall be verified in the field by the Engineer. Payment shall be made for Standard Manholes or Standard Drop Manholes at the prescribed depth measured from the top of the frame to the low pipe invert at the respective unit price bid. Payments for watertight manhole frame and covers and manhole vents will be considered to be included in the unit price bids for the respective manholes. Payment shall constitute full compensation for furnishing all equipment, tools, labor and incidentals and performance of all work necessary to install the manholes as specified. 07290-4 SECTION 07295 SANITARY SEWER SERVICE CONNECTIONS 07295.1 DESCRIPTION OF WORK The work covered under this section shall consist of furnishing all materials, labor, equipment, and services for the complete installation of a sanitary sewer service connection from the sanitary sewer (gravity) main line to the edge of the property to be served as shown on the project drawings. 07295.2 CONNECTION TO MAIN The standard sewer service connection shall be four (4) inches in diameter unless shown otherwise on the drawings, and shall connect to the main at a "wye" branch connection installed with the pipe line as it is being laid. The "wye" branch shall be of the same material as the main pipe line. Direct taps into the sewer main will not be acceptable unless approved by the Engineer prior to the laying of the main line. 07295.3 CONNECTION TO MANHOLE When shown on the drawings or directed by the Engineer, a sewer service connection shall be made into a manhole. The connection shall be made at the manhole invert. The invert shall be rebuilt so as to provide a smooth transition from service connection to main line. Inverts and benches shall be constructed in such a way as to prevent the deposition of solids in the manhole. 07295.4 SERVICE LINE The service line shall be installed from the "wye" branch connection to the edge of the public or utility right-of-way as shown on the plans. The sewer service line will be constructed of either PVC pipe (PVC schedule 40) pipe, or Ductile Iron (CL 350) as shown on the plans. When the service line pipe material is different from that of the main line a flexible, water tight, rubber transition coupling shall be used to join the service line to the "wye" connection. The service line shall be laid at a minimum grade of one (1.0) percent with a minimum cover of three (3.0) feet. Less than three (3) feet of cover will require the use of ductile iron pipe. 07295-1 07295.5 CLEANOUT AND PLUG At the edge of the public or utility righ:-of-way a "cleanout" shall be installed. The cleanout shall consist of a "wye" branch connection, forty-five (45) degree bend, riser pipe, and threaded plug installed flush with finished ground elevation. The end of the utility owner's sewer service connection shall terminate at the end of the pipe which will normally extend five (5) feet beyond the "wye" branch for the cleanout. A watertight plug shall be installed at the end of this line until such time as the property owner directs the utility owner to connect his facilities to the sewer system. 07295.6 MEASUREMENT AND PAYMENT Payment for the furnishing and installation of all service connections ("wye" branches, service line, clean outs, plugs, couplings, etc.) as described in this section and as shown on the plans, shall be covered under the contract unit price bid for each Sewer Service Connection. 07295-2 ate Of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director April 12, 2001 CITY OF HENDERSONVILLE EZRA ALLMAN P O BOX 1760 HENDERSONVILLE NC 28793 Subject: Dear Mr. Allmah: ern NCDENR 'NORTH CAROUNA 0 PPR 1 1 2001 Permit No. WQ0017801 Carolina Sewer -Public Henderson County The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. Sincerely, Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files William G Lapsley & Associates 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10 % post -consumer paper . omit No. WQ0017801 February 8,2000 ENGINEER'S CERTIFICATION - Partial v/ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, CA-IULI- A of HEN4E+1sortytuE_r H9"bEXUaN co. Project Name Location and County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within. substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature — -b- -- Registration No. Z 30 q 1 Date 8/Ze /ao .�` H CAP •Q 9li = SEAL 023091 T•FNGINEr;��g s The Division of Water Quality hereby acknowledges receipt and acceptance of this Etbiueo s Certification r otate of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director CITY OF HENDERSONVILLE EZRA ALLMAN P O BOX 1760 HENDERSONVILLE NC 28793 Dear Mr. Allmah: 1� k NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES. April 12, 2001 \1an�\ ppR wajta ourEc n NEV1L�— Subject: Permit Nor— 0017801 Carolina Sewer -Public Henderson County 1) The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. cc: Sincerely, GUL Thelma Williams Asheville Regional Office, Water Quality Section Central Files William G Lapsley & Associates 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50 % recycled/10 % post -consumer paper ermit No. WQ0017801 February 8,2000 ENGINEER'S CERTIFICATION - Partial ✓ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, CA-94UWA PAP-K cmC Op- KEntpFftiontylU.E_, N9wbSxt'.SaN co. Project Name Location and County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the constriction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature /J• �� Registration No. Z 30 9 1 Date 6/y8 /oo ``1�tiu un ngttr� �p•�Oc�(N C..P, play'% SEAL 023091 c .FyG1NEr:Q;r yOkAS Ja�o The Division of Water Qttality hereby acknowledges receipt and acceptance of this EVneffs Certificallon 4n r State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director CITY OF HENDERSONVILLE EZRA ALLMAN P O BOX 1760 HENDERSONVILLE NC 28793 Dear Mr. Allman: NCDENR NORTH CAROL ENVIRONMENT AN April 12, 2001 Subject: Permit No. WQ0017838 Creeksice 1 Sewer -Public Henderson County The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. Sincerely, Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files Patterson & Patterson 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-73.3-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50 % recycled/10 % post -consumer paper FINAL COMPLETION CERTIFICATION I, ROBERT PAUL PATTERSON, as a duly Registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, CreekSide Phase 1, for the permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. „i11111811111' Ss % ': .y Seal = i SEAL 023131 '2= •: 6 rO IN L Signature: bKo� GEC i ate: �/� � Robert Paul Patterson, P.E. N.C. P.E.#023131 NCDENR Permit No.: WQ0017838 P&P Project Name: CreekSide P&P Project No.: 99-06-21-ENG The Division of Water Quality hereby acknowledges receipt and acceptance of this Engineers Certification ic � Or l � 4A, n/J JUL 2 5 2000 EK I,IUHLI I Y OrU Norr, -Discharge Permit!in j - SURVEYING - PLANNING PATTERSON & PATTERSON PAUL PATTERSON WILLIAM PATI'ERSON PROFESSIONAL ENGINEER PROFESSIONAL LAND SURVEYOR P.O. BOX 1189 HENDERSONVILLE, NC28793-1189 1-V"92-6629 (ML. & FAX) MEMORANDUM July 19, 2000 North Carolina Division of Water Quality Water Quality Section Permits and Engineering Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Project: FINAL COMPLETION CERTIFICATION City of Hendersonville CreekSide Phase 1 Wastewater Collection System Henderson County P&P Job No.: 99-06-21-ENG NCDENRPermitNo. WQ0017838 Dated - March 27, 2000 Dear Sir/Madam: RECEIVED JUL 2 5 Z* N Won- oPelmil6nO Non-Discharg Please find attached herewith, a Completion Certification for the Wastewater Collection System to provide sewer service to CreekSide Subdivision - Phase 1 located on the south side of Haywood Road between Long John Mountain Estates and Carriage Park, Henderson County, North Carolina, with the installation of approximately 4433 linear feet (total) of eight (8) inch diameter PVC and/or Ductile Iron sewer line to serve forty-eight (48) lots. (As -built drawings will be mailed within a week.) I am hereby requesting final approval of this project from your office as well as the City of Hendersonville Water and Sewer Department. Should you have any questions or comments, please feel free to call. Thanks in advance for your cooperation in this matter. Sincerely, pe Paul Patterson, P.E. RECEIVED cc: File: 99-06-21-Eng JUL 2 S 2000 Ezra Allman, Director @ City of Hendersonville Water & Sewer 0,,$pg"ant i r J Non-Dischar n cul1ON c:Uotus\work\wordpro\wsspecs\certs\crk-slt.lwp gy Permllflng - SURVEYING - PLANNING ate of North Carolina Department of Environment and Natural Resources r• Division of Water Quality L Michael F.G. Easley, Governor NCDENR William G. Ross Jr., Secretary Kerr T. Stevens, Director NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES CITY OF HENDERSONVILLE EZRA ALLMAN P O BOX 1760 HENDERSON NC 28793 Dear Mr. Allman: April 12, 2001 APR 1 7 2001 Subject: Permit No. WQ001 Ken Ken 1 Sewer -Public . Henderson County The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor of the Asheville Regional Office at (828) 251-6208. Sincerely, Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files William G Lapsley & Associates 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper rt PpPrmhNo. WQ0017207 December 29, 1999 ENGINEER'S CERTIFICATION Partial X Final I, registered Professional Engineer in the State of North Carolina, having been authorized to obseryperiodical weekly, full time) the construction of the project, Project Nmne Location and County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the' construction was observed to be built within substantial compliance and intent of this permit, thVap rov laps and speci ations, and other supporting materials. Signature L/ Registration No. zz%8q Date 7 ' H CARPI,ti °•FESSIO°. qq� °. SEAL _ (22989 u.. WATERUACIiY8R,UnDIV OR 2 4 P0`o 1Vor?-pischarge pemtim�9 4 l William. G.. Lapsley &. Associates,' P.A. Consulting Engineers' and' Land 'Planners 1635 Asheville Highway Post Office Box 546 '- .Hendersonville, North :Carolina'28793 .. '. 828-697-7334 FAX.828-697-7333 ' - • William G. Lapsley,'P.E. - ' _ William R..Buie, P.E. G.-Thomas Jones III, P.E. April 17, 2000 . Mr. Kerr T. `Stevens, P.E.; Director - N.C. Division of Water Quality -1671 Mail Service Center ..Raleigh, NC 27699 RE: Project Certification Permit No. WQ0017207 Ken -Ken Development ' WGLA# 98181 " " Dear Mr.'Stevens: , Please find enclosed the certification for the above, referenced project. If you have any, questions or concerns, do not hesitate to contact our office. ' Sincerely, ' WILLIAM G. LAPSLEY & ASSOCIATES, P.A. F PJ APR 2 4 2000 " DIV. OF'WATER`QUALITY ' DIRECTOR'S OFFICE ' William R, Buie, P.E. v• CC; Mr. Ezra Allman, City'ofHendersonville RECEIVED 1NATERQUAL YSECIION ,' 2 4.2000 - tting • - - + `,ya Printed on Recycicd Pape, State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director April 12, 2001 CITY OF HENDERSONVILLE EZRA ALLMAN P I BOX 1760 HENDERSONVILLE NC 28793 1�r tip • 1 NCDENR NORTH CAROLINA DEPARTMENT_OFy Subject: Permit No. WQ0018746 Gann Village Sewer -Public Henderson County Dear Mr. Allman: The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. Sincerely, Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files Laughter, Austin & Associates 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919.733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper Jon H. Laughter Donald J. Austin Thomas P. Welbourn James D. Chambless, Sr. Laughter, Austin and Associates, P.A. Engineering • Planning • Land Surveying 131 FOURTH AVENUE EAST HENDERSONVILLE, NORTH CAROLINA 28792 COMPLETION CERTIFICATION Kerr T. Stevens, P.E., Director North Carolina Division of Water Quality Water Quality Section (828)692-9089 Fax (828) 693-8822 WATS 1-800-858-LAND Non Discharge Permitting Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617tl`f Project: FINAL COMPLETION City Of Hendersonville GANN VILLAGE, Phases 2 and 3 ` Wastewater Collection System Extension Henderson County 126 At LAA Job No. 00-333 (aka 00--M&) NCDENR-DWQ Permit No. W00018746 dated: August IS, 2000 Dear Mr. Stevens: Below, please find a COMPLETION CERTIFICATION for installation of the City Of Hendersonville's Wastewater Collection System Extension serving Gann Village consisting of 545 feet of 8-inch PVC gravity sewer main, four (4) precast manholes, cleanouts and all related appurtenances. The permitted discharge of 4,320 GPD will be tributary to existing wastewater collection system with Ieatment at the City of Hendersonville 's Balfour WWTP; NC0025534. I, JON H. LAUGHTER, as a duly Registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically the above installation, hereby certify that construction of the above referenced "permitted" project has been completed in substantial cori}Rlj,�nce with the intent of the approved DWQ Permit and in �rrr compliance with the DivS*r r&y Sewer Minimum Design Criteria (Fast -Track Permitting). Ess o>�9I9orth Carolina Registration Number 4066 Seal _ gEAL = = _ NO. 4066 The Dirision o,' Wate- Qca?4Y hereby : Date SIE-1? i Zs Zoe MCwesp\Gann Village\s,=00333 Laughter,' Austin and Associates, P.A. Engineering • Planning • Land Surveying 131 FOURTH AVENUE EAST HENDERSONVILLE, NORTH CAROLINA 28792 Jon H. Laughter Donald J. Austin Thomas P. Welbourn James D. Chambless, Sr. (828)692-9089 Fax (828) 693-8822 WATS 1-800-858-LAND LETTER OF TRANSMITTAL September 26, 2000 Kerr T. Stevens, P.E., Director Non -Discharge Permitting Unit NCDENR-Division Of Water Quality 1617 Mail Service Center SEP R onno Raleigh, NC 27699-1617 DIV. OF WATER QUALITY DIRECTOR'S OFFICE Project: City of Hendersonville Gann Village Wastewater Collection System Extension Henderson County LAA Job No. 00-333 (aka 00-126) Application For Plan Review Preliminary New Submital [ ] Revision Final Submittal information You Requested Additional Info. Requested For Approval �� As -Built Submittal �� Completion Certification Request To Start Construction For Your Files ] other NCDENR-DW Q Permit No. W 00018746 Dear Mr. Stevens, Please find the following items attached as required under the Division's permitting process and guidelines for the aforementioned project: RECEIVED ♦ Final Completion Certification of the completed project. OCT 3 2000 ♦ One (1) copy of"Construction Record Drawings" (As -Built). 1VATER QUALITY SECTION Non -Discharge Permitting t 1 t Kerr T. Stevens, P.E., Director Non -Discharge Permitting Unit NCDENR-Division Of Water Quality Page 2; September 26, 2000 Wastewater Collection System Extension City of Hendersonville Gann Village LAA00-333 (aka 00-126) If additional information is required or should you have any questions, please phone me at (828) 692-9089 or (800) 858-LAND. Facsimile (828) 693-8822. Respectfully submitted, LAUGHTER, AUSTIN AND ASSOCIATES, P.A. 4V/KS_ fighter, P.E. /jdc Enclosures: YES Proj. status: ASB/Cert. Action: cc: Project file M\CORRESMANN VILL 00126\LTR00333 mi dip \ \\1 \ \ xa \\ rs 90 967. we g. Aa Pg.. f51 O � ` N 0 T 8 \ \ \ AS-HUB,T DRAWING SHOWS INSTALLm UTRATTES AND APPURTENANCES AT APPROIOMATE LOCATION ONLY EZACT HORIZONTAL AND VERTICAL POSITIONS MUST BE VERIFIED IN THE FIELD. \ THIS DRAWING IS PROVIDED TO THE CITY OF HMERSONVR.I.E FOR RECORD PURPOSES ONLY. vn� I I II I I I I I l9C/N/TY MAP As. 674 Fes. in Environmental Management Commission NCDENR Division of Water Quality AP Permit Permit No. W00018746 RECE Dated: 8-18-2000 OCT 3 2000 01ATER QUALITY SLe Ncn-Di charge permitt I CITY OF HENDERSONVILLE 457 WATER & SEWER DEPARTMENT A.d 9((, PG (67 PO Box 1780 HENDERSONVM, NORTH CAROUNA 28792 The Division of Water Quality hereby 828-697-3063 acknowledges receipt and acceptance of this Engineers - Certification AS BUILT To Serve GANN VILLAGE TOWNHOU595 1922 HAYWOOD ROAD �p[urr�,r[rrry A - 3j*w O+a71Ms J+51.21 CAR6'�i�i E - 51J W 0+W *U 1+9143 d� •' � / A, hZWD4e50AWUZ 7WP. APJJDE250A COUAIY, N.C. �1 LAUGHTER, AU577N AND A55OCIATES, P.A. 131 FOURTH AVENUE EAST .406G HENDER5OAWLLE, NORTH CAROLINA 28792 O (MB) 692-9069 o'¢V CNDS CXEIXEO BY WIT z n P m im rw • ORAVN aY scw.[ 9/Z1/L'O (rI ` 0. DATE BY APPRV. DESCRIPTION 1 x arQ v D0 REVISIONS 4146091 � �¢ r¢r: vuvnn rac OAfl7 EWER MAIN EXTENSION OWN2R/DEl/ELOPE2.' TOM AND SUSAN CANN P.O. Box 2826 HENDERSONl4LLE, N. C. 28793 704 693-1231 70¢ 693—I428 o I ;® AOAD "IE` J08 NO. 00-999 DISC. N0. ate of North Carolina Department of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe; Ph.D., Acting Director Division of Water Quality Mr. Ezra Allman, Director Hendersonville Water and City of Hendersonville WATER QUALITY SECTION August 16, 2001 Sewer Department Post Office Box 1760 Hendersonville, North Carolina 28793-1760 'Dear Mr. Allman: NCDENR NORTH CAROLINA DEPARTMENT OF ,ENVIRONMENT AND NATURAL RESOURCES SUBJECT: Permit No. WQ0020305 City of Hendersonville Creek Side -Phase II Wastewater Collection System Extension Henderson County In accordance with your application received August 13, 2001, please find attached Permit No.WQ0020305 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permiee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1,2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It Ezra Allman August 16, 2001 Page Two shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 3,020 linear feet of eight (8) inch gravity sewer to serve Phase II as part of the Creek Side project and the discharge of 8,640 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received August 13, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, Gregory J. Thorpe, Ph.D. Enclosure xc: Henderson County Health Department Non -Discharge Permitting Unit Paul Patterson Roy Davis NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted at least once per year. -qqqqq g. Inspection and maintenance records shall be maintained for a period of at least thre years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a .pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 16th day of August, 2001. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ,, 4'Gregory J. Thorpe Ph.D., Acting Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0020305 Permit No. WQ0020305 August 16, 2001 ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Creek Side -Phase II Hendersonville, N.C. Henderson County for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design. Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 State of North Carolina Department of Environment and Natural Division of Water Quality NON -DISCHARGE PERMIT APPLICATION GRAVITY SEWER COLLECTION SYSTEMS (Pump stations, force mains and pressure sewers are not to be included as part of this (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) ws 1 v1111 package.) INSTRUCTIONS: Please indicate that you have included the following list of application requirements by signing your initials in the space provided next to each item. X A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to the content of this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. Failure to submit all required items will lead to additional processing and review time for the permit application. X B. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). C. Flow Acceptance Letters — If the owner of the W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the W WTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/W WTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the. application date. Intergovernmental , agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. _ D. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately owned public utility, submit two copies of the Ceriificate of Public'Comenience grid Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise,approval is expected. _ E. Operational Agreements — Submit one original and two copies of a properly executed Operational Agreement if the sewer extension will be serving residential or commercial lots (houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use Form HOA 10/99. If theapplicant is a developer, use Form DEV 10/99. L GENERAL INFORMATION: Application Number:. (tobecompletedbyDWQ) 1. Applicant's name (name of the municipality, corporation, individual, etc.): City of Hendersonville 2. Owner's or signing official's name and title (15A NCAC 2H .0206(b)): Ezra Allman, Director. 3. Name and complete address of applicant: City of Hendersonville City: Hendersonville State: NC Zip: 28793-1760 Telephone number: (828 ) 697-3063 • • Facsimile number: ( 828'' ) 697-1707 4. Project name (name of the subdivision, facility or establishment, etc.): 1HreekS9' ad PBas eWLT E if ne sionm FORM: GSPA 02/00 Page 1 of 4. . 5. County where project is located: 6'. Nameland complete address of e P.O. Box 1189 City: Hendersonville State: Zip: 28793-1189 Telephone number: ( 828 ) 692-6629' Facsimile number: ( 828 ) 692-6629 7. Name and affiliation of contact person who can answer questions about application: Paul Patterson, P.E. or Sam Fore (a, City of Hendersonville II. PERMIT INFORMATION: 1. Project is: X new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number 3. Applicant is: X public private. and the issuance date If private, units (lots, townhomes, etc.) are: leased (Skip to Section III.) sold If sold, facilities owned by a: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) III. INFORMATION ON WASTEWATER: 1. Please provide a one- or two -word description specifying the origin of the wastewater (school, subdivision, hospital, commercial facility, industry, apartments, condomintums,;etc.):. Aesideuiial/Subdivision 2. Volume of wastewater generated by this project: - 1=10UP07 gallons.per day . 3. Explanation of how wastewater flow was determined (15A NCAC 2H .0219(1)): ' 24 homes w/3 bedrooms x 360 sad = x Rnn fl„a .. .. „ 4. Nature of wastewater: 100 % Domestic/Commercial; % Industrial; Other waste -specify: 5. If wastewater is industrial in nature: a. Level of pretreatment that has been provided to'ehsure protection of the receiving collection system and wastewater treatment facility: ' N/A b. If pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment'permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: 1. Brief project description: Gravity sewer extension to serve Phase 2 and tie adjacent subdivision & remove lift station. Additionally, provide a fututre gravity line for adjacent subdivision. ' 2. Owner and name of wastewater treatment facility (W WTF) receiving wastewater (See Instruction C.): Citv of Hendersonville W WTF 3. WWTF permit number (NC00***** or W000*****): NCiftT235 FORM: GSPA 02/00 Page 2 of 4 .mmmary of GRAVITY SEWER to be permitted: Diameter (inches) Length (linear feet) 8'•' Ductile Iron CL350 1,593 . 8" SDR35 PVC 1,427 5. Does the subject gravity sewer collection system comply with the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200? X. Yes: No. If no, please identify criteria and explain: IMPORTANT: If you responded No to question IV:5 above, the completed application package, including two (2) conies of plans specifications supporting information and any other materials, should be submitted for an individual permit. The completed application package, including all supporting information and materials should be sent to the following address: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESO DIVISION OF WATER QUALITY NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27690-1617 512 NORTH SALISBURY STREET, RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 FORM: GSPA 02/00 Page 3. of 4. V. CERTIFICATIONS: Professional Engineer's Certification: I, Robert Paul Patterson. P.E. attest that this application for CreekSide - Phase 2, Sewer Extension has been reviewed by me and is accurate, complete and consistent with information supplied in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations and Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143- 215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: �.�`OtIIIIIIIIIII ��N CAR �I'�. `�� Q m mmummm ��� �L 023131 sz ;F�pTti GIN �`;:mm�r' UL�PP��. "„nmM�A Applicant's Certification: I, Ezra Allman. Director attest that this application for CreekSide - Phase 2, Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 5 L — d FORM: GSPA 02/00 Page 4 of 4 tk) CO © O aC) 3C�� Mountain Building &Development, Inc. Mountain6ank 415 7 .Hendersonville, NC 28792 32 Mistletoe Trail Hendersonville, NC 28791 � 828-693-1112 66-1210/531 Az qzoo/ � TO THE 1lldgl T ^ � ORDER A //� 2) E. JV. R. �JOO, 00 ORDER OF /V 1, e —� A IZED SIGNATURE M' MEMO CITY OF HENDERSONVILLE CITY COUNCIL: Pred H. Niehotf, Jr. J. CRITENDEN HARIEY "The City. of Four Seasons" Mayor MaryJo Padgett LONDA MURRAY Mayor Pro -Tern WATER AND SEWER DEPARTMENT Chris A. Caner MARY JO PADGETT City Manager Ezra Allman, Director ' Tammie K. Drake BARBARA VOu2 City Clerk ' LETTER OF TRANSMITTAL Mr. Kim H. Colson, P.E., Supervisor August 9, 2001 N. C. Department of Environment & Natural Resources Division of Water Quality 1617 Mail Service Center Raleigh, N.C. 27699-1617 This project is being forwarded to you for your review and approval. Submitted By: t �- 'Water and Sewer Department CITY -OF HENDERSONVILLE cc: Project File �nj i tea" �JIJ 6U67001 318 Fourth Avenue East P.O. Box 1760- _ Phone: (828). 697-3063 Hendersonville, NC 28792 Heridersoriville, NC 28793 - Fax: (828) 697-1707 e-mail: eallman@cityofhendersonville.org wvnv.cityofhendersonville.org C�Cp ��3c�s CITY OF HENDERSONVILLE CITY COUNCIL: rred H. Niehoff, Jr. - "The City of Four Seasons" J. CRr TENDEN HARLEY Mayor - Mary Jo Padgett LONDA MURRAY Mayor Pro -Tern WATER AND SEWER DEPARTMENT Chris A. Carter City Manager Ezra Allman, Director. MARY JO PADGEIT Tammie K. Drake BARBARA VOLK City Clerk August 9, 2001 Mr. Kim H. Colson, P.E., Supervisor N. C. Department of Environment & Natural Resources Division of Water Quality 1617 Mail Service Center . Raleigh, N.C. 27699-1617 Re: CAPACITY ACCEPTANCE LETTER Creekside-Phase 2, Sewer' Line Extension Dear Mr. Colson: This is to, advise you that have reviewed the plans and specifications prepared by Mr. Robert Paul Patterson, P.E., of Patterson & Patterson, of Hendersonville, N.C. for a proposed gravity sewer collection system io serve the referenced project. It is my opini6n that the City of Hendersonville has the capacity to accept the additional wastewater flows that will be generated by this project. I I . This project is being submitted via Fast Track for your review and approval. If you have any questions, call me at (828) 697-3063. Sincerely, ra,Alhnan, Director Water and Sewer Department CITY OF HENDERSONVILLE D cc: Project file AUG 1 3 2001 i 318 Fourth Avenue East P.O. Box 1760 Phone: (828) 697-3063 Hendersonville, INC. 28792 Hendersonville, NC 28793 Fax: (828) 697-1707 e-mail: eallman@cityothendersonville.org - w .cityofhendersonville.org ate!ofNorth Carolina Depaent of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director Division of Water Quality WATER QUALITY SECTION October 4, 2001 Mr. Ezra Allman, Director Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793-1760 Dear Mr. Allman: STURMA_01 Ad � NCDENR NORM CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES SUBJECT: Permit No. WQ0020526 Charleston at the Meadows, Phase I City of Hendersonville Wastewater Collection System Extension V Hpndersonville County In accordance with your application received September 28, 2001, please find attached Permit No.W00020526 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. Ezra Allman October 4, 2001 Page Two In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 505 linear feet of eight (8) inch gravity sewer; to serve Charleston at the Meadows, Phase I as part of the City of Hendersonville's wastewater collection system and the discharge of approximately 9,360 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received September 28, 2001 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, J. Thorpe, Ph.D. Enclosure xc: Henderson County Health Department Non -Discharge Permitting Unit Paul Patterson Roy Davis NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's GeneralPermit NCG0100000, and any requirements pertaining to wetlands under15A NCAC 26 .0200 and 15A NCAC 2H.0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208' as soon as possible, but in no case more than 24 hours or on the next working. day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. ., Persons reporting such occurrences by telephone shall also file a written report in letterform within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 4th day of October, 2001. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION gregory J' Thorpe, .Ph.D., Acting Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number W00020526• Permit No. WQ0020526 October 4, 2001 ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically,, weekly, full time) the construction of the project, Charleston at the Meadows. Phase[. Hendersonville. NC _Henderson County forthe Project Name Location and County Permittee hereby state that, to the best of my abilities; due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 cae of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director October 12, 2001 CHRIS A. CARTER CITY OF HENDERSONVILLE P.O. Box 1670 HENDERSONVILLE, NC 28793 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Application No. WL- QCSOQ07 Additional Information Request Hendersonville Collection System Henderson County Dear Mr. Carter: The Non -Discharge Permitting Unit has completed a preliminary review of the subject application. The following questions concern items that the Central Office was unable to obtain from the submitted application. Please answer these questions as thoroughly as possible, so that the review process may be concluded and the permit drafting stage initiated. Please note and/or address the attached information request by November 11, 2001. In addition, please expect a site visit from a representative of the Asheville Regional Office in the near future. R �p L5 0 V I� Also enclosed with this letter are the following documents for your reference�� i Draft permit shell ,�� 16 2OOI History of the collection system permitting process i CIP development plan from the Rural Development Center WATER GJ"_L!:Y SEGTIOlJ i Division record ]seeping requirements ASHEVILII I,��I:.lAL OFFICE Please reference the subject permit application number when providing the requested information. All information should be signed, sealed, and submitted in triplicate to my attention at the address below. The_ information requested by this letter, must be submitted on or before November 11, 2001 or the Division will return your application as incomplete in accordance with 15A N.C.A.C. 2H .0200 and your Hendersonville collection system will be considered to be operating in non-compliance. If you have any questions, comments or suggestions regarding this request, or the collection system permitting process in general, please call me at (919) 733-5083, extension 533. Sincerely, za�eo Nathaniel Thomburg Environmental Engineer Non -Discharge Permitting Unit cc:wAsheya 1EaR_eg ouallOffcel4WateaQua�p Dennis Frady — OCR, City of Hendersonville Permit File 1617 Mail Service Center, Raleigh NC 27699-1617 Telephone 919-733-5083 FAX 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Application No. WQCS00070 Hendersonville Collection System Attachment Page 1 General 1. Has the City of Hendersonville been delegated to self permit pump stations, force mains, gravity lines or pressure sewers? If so, please submit a completed Form DLPSSA 07/00. 2. The signing official for the submitted application was Chris Carter. Please note that per Regulation 15A NCAC 2H .0206(b), only a principal executive officer, ranking elected official or duly authorized employee may sign. Please note that duly authorized employees must provide proof that they have been authorized to sign this application. Please clarify if Mr. Carter is an executive officer, elected official or authorized employee. Division of Water Quality records indicate that the City of Hendersonville WWTP (NC0025534) is currently under a moratorium and SOC. What is the status of Hendersonville's moratorium and SOC? Collection System Information: 1. What is the City of Hendersonville's daily average flow (QA.)? 2. Item 111.5 states that Hendersonville's wastewater is approximately 12% industrial. Per Instruction F, please provide the basis and/or assumption used in developing this estimate. 3. Does the Hendersonville Collection System currently conduct a pretreatment program for industrial wastewater? fIf not, please provide a rough time estimate as to when a pretreatment program could be in place. 4. Per Instruction F, please provide the basis and/or assumption used in developing the total miles of sewer estimate. 5. Are all of Hendersonville's fourteen (14) pump stations equipped with signs that indicate pump station ID, emergency phone numbers and instructions to call in the event of an alarm or visible problem? If not, please submit a compliance schedule as to when these signs can be posted in a visible location at each pump station. 6. Do Hendersonville's pump stations have public restricted access? Restricted access includes, at a minimum, fencing (preferred), locked wet wells and locked control panels. If not, please submit a compliance schedule indicating when all pump stations will have restricted access. 7. Does any overflow piping exist in the Hendersonville Collection System? Overflow piping is defined as exits from manholes and pump stations to surface waters. If overflow piping does exist, the pipes must be capped on both ends or removed. 8. Please clarify whether or not there are any locations of known, chronic discharge, overflow, bypass, etc. that are planned for correction. If so, please provide their locations and a schedule for correcting them. ication No. WQCS00070 Hendersonville Collection System Attachment Page 2 9. The application states that Hendersonville has twenty five (25) high priority lines. Please verify this list of sewer lines because it will be added to your permit as Attachment A for Condition VA. Please note that high priority lines are defined as "any aerial line, sub -waterway crossing, line contacting surface waters, siphon, line positioned parallel to streambanks that are subject to eroding in such a manner that may threaten the sewer line, or line designated as high priority in a permit." [15A NCAC 2H .0227 (b) (2)] Administration of the Collection Svstem: 1. Please provide a detailed description of your Capital Improvement Plan (CIP). The plan should cover a minimum of three years, should be only for the collection system and shall not be dependent upon grants and loans for an extended period of time. 2. Is the Hendersonville's collection system O&M budget only for collection systems, or is it shared with the water and/or wastewater treatment plant(s)? 3. Item IV.5 states that Hendersonville does have a grease ordinance. However, it is unclear whether or not this ordinance provides authority to enforce against both residential and commercial users, and if it requires grease traps for all new establishments. If these provisions are not in the existing ordinance, please submit a compliance schedule that indicates when the ordinance will be modified and enacted. 4. The application indicates that Hendersonville has an inspection program, however, how are repeat violators enforced against? Please clarify whether or not Hendersonville's grease inspection program includes enforcement. If not, please submit a compliance schedule as to when the program will be modified to include grease enforcement. 5. Does the City of Hendersonville have a grease education program for both commercial and residential users? The program is intended to educate the public about the "do's and don'ts" of grease disposal, and to reduce the occurrence of Sanitary Sewer Overflows (SSOs) due to grease blockages. Acceptable forms of education include door hangers, flyers, newspaper ads, utility bill stuffers, etc. If you would like examples of grease education materials, please contact me at nathaniel.thornbure@ncmail.net or at (919) 733-5053 x 533. Operation and Maintenance of the Collection Svstem: 1. Are all pump stations equipped with visual and audio alarms? Is telemetry installed at any of the pump stations? If the pump stations are not equipped with alarms and do not have advanced telemetry (i.e. SCADA), then please submit a compliance schedule indicated when audio and visual alarms would be installed. Application No. WQCS00070 Hendersonville Collection System Attachment Page 3 Operation and Maintenance of the Collection Svstem (continued): 2. The following parameters were not found on your comprehensive map: approximate age of pipe, approximate number of active service taps, pump station location, pump station identification, pump type, pump capacity and location of all tributary collection system extensions. Note the permittee has 10 years to complete the comprehensive map at a minimum of 10% per year. 3. Please note that as -built plans must be maintained for the life of the project. 4. Please clarify how long it takes for information concerning new wastewater collection system extensions to be added into the Hendersonville mapping system. 5. For your reference, Hendersonville's SSO Evaluation / Record Log should contain at a minimum: ➢ Date and time of evaluation ➢ Date and estimated time of spill ➢ Volume discharged and nature of complaint ➢ Location and duration of discharge ➢ Division contact ➢ Final destination of spill ➢ Corrective actions taken ➢ Environmental/human impacts ➢ How the spill was discovered 6. Please clarify whether or not the Hendersonville wastewater collection system has a written pump station failure contingency plan that outlines procedures to follow for pump or power failure at pump stations. Note that the contingency plan should be available at each pump station and all other pertinent locations. 7. How often are alarms, telemetry and auxiliary equipment tested? Are generators tested under load? Are permanent pumps set to alternate to allow varied operation? 8. Does a plan exist to do routine pump station inspection and maintenance? The plan should include inspecting, cleaning and removing debris from the pump station structure, outside perimeter and wet well. All valves should be exercised and the pumps maintained based on manufacturer recommendation. Please note that documentation shall be kept of all pump station inspection and maintenance. 9. Please note that pump stations must be inspected daily (including weekends and holidays), or at least once per week if telemetry is installed. 10. Item V.7 states that maintenance logs are reviewed annually. Although no permit condition requires frequent log review, the Division recommends that the logs be reviewed more often to help identify problem areas, and increase preventative maintenance of the system. 11. Item V.8 states that the entire collection system is inspected every two years. Please note that the permit shall require that the entire collection system be inspected at least once per year and documentation of inspection kept. ..:.cation No. WQCS00070 Hendersonville Collection System Attachment Page 4 General Information: 1. The latest permit shell is attached for your review. After reading the permit shell, identify any additional conditions not discussed above that may not be met the day of permit issuance and provide compliance dates for meeting these specific conditions. 2. Once compliance dates are submitted, the Division will review them for approval. A draft permit will be reviewed by the Non Discharge Permitting Unit, the Asheville Regional Office and Hendersonville for final concurrence. The final permit will then be issued and renewed by the City every five -years. 3. Based on your current permitted flow (multiple treatment facilities are combined), an annual fee of $1090 will be charged. 4. Please note that all records and logs shall be kept on site for a minimum of three (3) years, and shall be made available to DWQ inspectors upon request. Pe of North Carolina epartment of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Secretary Kerr T. Stevens, Director Division of Water Quality WATER QUALITY SECTION January 17, 2001 Mr. Ezra W. Allman Director of Water and Sewer Department City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793 Dear Mr. Allman: NORTH CAROUNA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES SUBJECT: Permit No. WQ0019424 City of Hendersonville Hamilton's Landing Wastewater Collection System Extension pnderson County In accordance with your application received December 12, 2000, please find attached Permit No. WQ0019424 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 1 5A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North,Carolina-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -Licensed Professional Engineer to the licensing board. Ezra W. Allman Page Two January 17, 2001 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 559 linear feet of eight inch gravity sewer to serve fifteen (15) homes as part of the Hamilton's Landing sewage collection system, and the discharge of approximately 5,4000 gallons per day of collected domestic wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received December 12, 2000, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's Wastewater Treatment facility (NPDES Permit No. NC0025534) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request and adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, Kerr T. Stevens xc: Henderson County Health Department Sam Laughter John Jeter Roy M. Davis NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT this permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected daily, as defined in 15A NCAC 2B .0503(5), until July 1, 2001; and thereafter, pump stations shall be inspected every day. Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at three years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, .including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control I requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to betaken to ensure that the problem does not recur. Permit issued this the 17th day of January, 2001 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ssion Permit Number WQ0019424 Permit No. WQ0019424 January 17, 2001 ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 ppppp� P e of North Carolina PDe of Environment and Natural Resources Asheville Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director Division of Water Quality WATER QUALITY SECTION December 3, 2001 MEMORANDUM &� NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NArURAL RESOURCES TO: Nathaniel Th ornburg FROM:Roy Davis ' SUBJECT: Collection System Permit Application City of Hendersonville Application Number WQC00070 Henderson County I have before me my copy of the documents received from the City of Hendersonville in response to your request for additional information. I completed my review with the information at hand. The City of Hendersonville does an excellent job of maintaining and operating its sewer system. It is my recommendation that the City of Hendersonville be issued a permit for its wastewater collection system.. If you need to discuss this project, please do not hesitate to call me.. 0007000L.01 59 Woodfin Place, Asheville North Carolina 28801 Telephone 828-251-6208 FAX 828-251-6452 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper e of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director CITY OF HENDERSONVILLE EZRA ALLMAN P O BOX 1760 HENDERSONVILLE NC 28793 Dear Mr. Allman: AM�� NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES April 27, 2001 Subject: Permit No. WQ0017640 Short Street Sewer -Public Henderson County The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. i7APR Sincerely, 0 20 11, Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files Laughter, Austin & Associates 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733.5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50 % recycled/10 % post -consumer paper Jon H. Laughter Donald J. Austin Thomas P. Welboum James D. Chambless, Sr. Laughter, Austin and Associates, P.A. Engineering • Planning • Land Surveying 131 FOURTH AVENUE EAST HENDERSONVILLE, NORTH CAROLINA 28792 COMPLETION CERTIFICATION (828)692-9089 Fax (828) 693-8822 WATS 1-800-858-LAND Kerr T. Stevens, P.E., Director North Carolina Division of Water Quality Water Quality Section Non Discharge Permitting Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 2 Project: FINAL COMPLETION j T City Of Hendersonville Short Street Extension Wastewater Collection System Extension Henderson County LAA Job No. 99-321 NCDENR-DWQ Permit No. W00017640 dated: November 17, 1999 Dear Mr. Stevens: Below, please find a COMPLETION CERTIFICATION for installation of the City Of Hendersonville's Wastewater Collection System Extension serving Short Street Extension consisting of approximately 538 feet of 8-inch PVC gravity sewer main, three (3) precast manholes, one cleanout, mid all related appurtenances. The permitted discharge of 750 GPD will be tributary to existing wastewater collection system with treatment at the City of Hendersonville's Balfour WWTP; NC0025534. 1, JON H. LAUGHTER, as a duly Registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically the above installation, hereby certify that construction of the above referenced "permitted" project „has been completed in substantial compliance with the intent of the approved DWQ Permit and in compliance with the Divigiou7sQravity Sewer Minimum Design Criteria (Fast -Track Permitting). ,�`,`Y, CA/t OZ fill, ;North Carolina Registration Number 4066 Seal �' SEAL } = N0.4065 ? Signature -Date-. Date. 03/2//Z00 The Division ofV.'aterClu;i;q„^-:et;xUnydocumensleweAcec99321 acknowledges receipt and accepisnze ul'tl•ds Engineers. CeniGcation PNON NPDES FACILITY AND PERMIT DATA 04/19/01 13:46:45 ON TRXID 5OU KEY WQ0017640 DATA FACILITY APPLYING FOR PERMIT APP/PERMIT FEE-$ 400.00 REGION IY NAME> HENDERSON LITVILLE, CITY -SHORT ST1 COUNTY> HENDERSON 01 ADDRESS: MAILING (REQUIRED) ENGINEER: LAUGHTER, AUSTIN & ASSOCI STREET: PO BOX 1760 STREET: 131 FOURTH AVENUE EAST CITY: HENDERSONVILLE ST NC ZIP 28793 CITY: HENDERSONVILLE ST NC ZIP 28731 TELEPHONE 828 697 3063 TELEPHONE: 828 692 9089 STATE CONTACT> SERG FACILITY CONTACT EZRA ALLMAN TYPE OF PROJECT> SEWERS -PUBLIC LAT: LONG: DATE APP RCVD 11/08/99 N=NEW,M=MODIFICATION,R=REISSUE> N DATE ACKNOWLEDGED 11/08/99 DATE REVIEWED / / RETURN DATE REG COMM REQS 11/09/99 DATE DENIED / / NPDES #- NCO025534 REG COMM RCVD 11/12/99 DATE RETURNED / / TRIB Q .0007 MGD ADD INFO REQS 12/29/99 OT AG COM REQS / / TRIB DATE- 11/17/99 ADD INFO RCVD 03/31/00 OT AG COM RCVD END STAT APP P 06/29/00 DATE ISSUED 11/17/99 DATE EXPIRE FEE CODE( 7)1=(>lMGD),2=(>IOKGD),3=(>1KGD),4=(<1KGD+SF),5=(S>300A),6=(S<=300A), 7=(SENDEL),8=(SEDEL),9=(CLREC),0=(NO FEE) DISC CODES 02 ASN/CHG PRMT ENG CERT DATE 04/11/01 LAST NOV DATE / / CONBILL( ) COMMENTS: 750GPD MESSAGE: *** DATA MODIFIED SUCCESSFULLY *** Laughter, Austin and Associates, P.A. Engineering • Planning • Land Surveying Q 131 FOURTH AVENUE EAST HENDERSONVILLE, NORTH CAR OLINA 28792 DILI /RFC OF �OQ/ Jon H. Laughter % Q(/ qTE Donald J. Austin OR'S (97-9089 Thomas P. Welbourn Fax (828 93-8822 James D. Chambless, Sr. WATS 1-800-858-LAND LETTER OF TRANSMITTAL March 20, 2001 Mr. Kerr T. Stevens, P.E., Director North Carolina Department of Environment and Natural Resources Divis �n ofWater Quality ,Non -Discharge Permitting Unit 11617 Mail Service Center Raleigh; North Carolina 27699-1617 Project. Short Street Estcrsion City of Hendersonville Wastewater Collection System Henderson County LAA Job No. 99-321 Application Freliminazy 1 Nm Submittal [ ] Revision Final Submittal Information You Requested ] Additional Info. Requested For Approval As -Built Submittal Completion CediBeation Request To Start Consaudion For Your Files other • Fast Track • Permit No. W00017640 Dear Mr. Stevens, Please find the following items enclosed as required by Division of Water Quality regulations for "Fast Track" projects for the aforementioned project: 1.) One (1) copy of Record Drawings . 2.) A Completion Certification. 1 o10 Kerr T. Stevens, Director NCDENR-DWQ Non -Discharge Permitting Unit Page 2; March 20, 2001 Short Street Extension- Gravity Sewer Extn. City of Hendersonville Henderson County LAA Job No. 99-321 If additional information is required or should you have any questions, please phone me at (828) 692-9089 or (800) 858-LAND. Facsimile (828) 693-8822. Respectfully submitted, LAUGHTER, AUSTIN AND ASSOCIATES, P.A. Jon H. Laughter, P.E. !dc Enclosures: YES Proj. status: 1PR Action: Review & approve cc: Project file Cnny docunnenWsewer\LTR99321eert . e of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Gregory J. Thorpe, Ph D., Acting Director December 14, Hendersonville City Ezra Allman PO Box 1760 Hendersonville NC .28793 '4�jEWA NCDENR NORTH CAROLINA DEPARTMENT OF IRCES Subject: Permit No. WQ0019148 Hendersonville City -Kay Thom Henderson County Dear Mrs. Allman The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non- conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208 Sino- ely, ��, � Jennifer Willis cc: Asheville Regional Office, Water Quality Section Central Files Laughter Austin & Assoc. 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10 % post -consumer paper Jon H.Laughter Donald J. Austin Thomas P. Welboum James D. Chanrbless, Sr. lb J Laughter, Austin and Associates, P.A. Engineering • Planning • Land Surveying 131 FOURTH AVENUE EAST HENDERSONVILLE, NORTH CAROLINA 28792 (828)692-9089 Fax (828) 693-8822 WATS 1-800-858-LAND COMPLETION CERTIFICATION 'lam /� Kerr T. Stevens P.E., Director Forth Carolina Division of Water Quality dam. NOV 1 ,� 2001 ' /Water Quality Section DIV. OF L; Non -Discharge Permitting Unit I Wn ,Ar?,r D1RFC 0; o OFFICE o 1617 Mail Service Center Raleigh, North Carolina 27699-1617 !C Project: City of Hendersonville -' Kay Thomas Drive Wastewater Collection System Extension Henderson County � � ct_, `- LAA Job No. 98498 NCDENR-DWQ Permit No. W00019148 dated: November 14, 2000 Dear Mr. Stevens: Below, please find a Final COMPLETION CERTIFICATION for the construction of approximately 537 linear feet of 8-inch PVC gravity sewer, four (4) precast manholes and all related appurtenances to serve 12 three -bedroom units of the Kay Thomas Drive project and the discharge of 4,320 GPD of collected wastewater into the City of Hendersonville's existing sewerage system. Collected sewage and wastewater shall be treated in the City of Hendersonville Wastewater Treatment Facility (NPDES Permit No. NC0025534) prior to final discharge. I, JON H. LAUGHTER, as a duly Registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically the above installation, hereby certify that construction of the above referenced "permitted" project has been completed in substantial compliance with the intent of the approved DWQ Permit; 15A NCAC 2H .0200; and the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting matgieW. CAR31•,, =North Carolina Registration Number 4066 Seal `_ of �y•,9' SEAL ` = NC. 4066 . ✓ yiP� . Signature : - Date 019L' 7, tool ©N,H;3 (BITER C\\niy doc¢ werkswrcer98498 The Division of water Quality hereby acknowledges receipt and accW.=ce of this Engineers Certi on 217 mate of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director RIDGEVIEW CONDO HOA JOYCE KRECH 104 FERN CREEK DRIVE FLAT ROCK NC 28731 Dear Mr. Krech: 1OR MAI NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES May 10, 2001�_ MhAY 1 4 `ZNj Subject: Permit No. WQ0019064 18th Fair Sewer -Private Henderson County The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. cc: Sincerely, Thelma Williams Asheville Regional Office, Water Quality Section Central Files Laughter, Austin & Associates 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper ppp NON NPDES FACILITY AND PERMIT DATA 04/20/01 15:35:43 PDA ON TRXID 50U KEY WQ0019064 ACILITY APPLYING FOR PERMIT APP/PERMIT FEE-$ 400.00 REGION NAME> RIDGEVIEW CONDO HOA-18TH FAIR2 COUNTY> HENDERSON 01 ADDRESS: MAILING (REQUIRED) ENGINEER: LAUGHTER, AUSTIN & ASSOC. STREET: 104 FERN CREEK DRIVE STREET: 131 FOURTH AVE EAST CITY: FLAT ROCK ST NC ZIP 28731 CITY: HENDERSONVILLE ST NC ZIP 28792 TELEPHONE 828 692 9138 TELEPHONE: 828 692 9089 STATE CONTACT> SERG FACILITY CONTACT JOYCE KRECH TYPE OF PROJECT> SEWER -PRIVATE LAT: LONG: DATE APP RCVD 09/20/00 N=NEW,M=MODIFICATION,R=REISSUE> N DATE ACKNOWLEDGED 10/01/00 DATE REVIEWED 10/01/00 RETURN DATE 12/02/00 REG COMM REQS 10/04/00 DATE DENIED / / NPDES #- REG COMM RCVD 10/05/00 DATE RETURNED / / TRIB Q .0000 MGD ADD INFO REQS / / OT AG CON REQS / / TRIB DATE- ADD INFO RCVD / / OT AG CON RCVD END STAT APP P 12/19/00 DATE ISSUED 10/24/00 DATE EXPIRE FEE CODE( 7)1=(>1MGD),2=(>10KGD),3=(>1KGD),4=(<1KGD+SF),5=(S>300A),6=(S<=300A), 7=(SENDEL),8=(SEDEL),9=(CLREC),O=(NO FEE) DISC CODES 06 ASN/CHG PRMT ENG CERT DATE 04/20/01 LAST NOV DATE / / CONBILL( ) COMMENTS: MESSAGE: *** DATA MODIFIED SUCCESSFULLY *** NON NPDES FACILITY•AND PERMIT DATA 05/09/01 09:53:49 ,,PTION TRXID 5OU KEY WQ0019064 ..ANAL DATA FACILITY APPLYING FOR PERMIT APP/PERMIT FEE-$ 400.00 REGION 9ACILITY NAME> RIDGEVIEW CONDO HOA-18TH FAIR2 COUNTY> HENDERSON O1 ADDRESS: MAILING (REQUIRED) ENGINEER: LAUGHTER, AUSTIN & ASSOC. STREET: 104 FERN CREEK DRIVE STREET: 131 FOURTH AVE EAST CITY: FLAT ROCK ST NC ZIP 28731 CITY: HENDERSONVILLE ST NC ZIP 28792 TELEPHONE 828 692 9138 TELEPHONE: 828 692 9089 STATE CONTACT> SERG - FACILITY CONTACT JOYCE KRECH TYPE OF PROJECT> SEWER -PRIVATE LAT: LONG: DATE APP RCVD 09/20/00 N=NEW,M=MODIFICATION,R=REISSUE> N DATE ACKNOWLEDGED 10/01/00 DATE REVIEWED 10/01/00 RETURN DATE 12/02/00 REG COMM REQS 10/04/00 DATE DENIED / / NPDES #- REG COMM RCVD 10/05/00 DATE RETURNED / / TRIB Q .0000 MGD ADD INFO REQS / / OT AG COM REQS / / TRIB DATE- ADD INFO RCVD / '/ OT AG COM RCVD END STAT APP P 12/19/00 DATE ISSUED 10/24/00 DATE EXPIRE FEE CODE( 7)1=(>1MGD),2=(>IOKGD),3=(>1KGD),4=(<lKGD+SF),5=(S>300A), 6=(S<=300A), 7=(SENDEL),8=(SEDEL),9=(CLREC), 0=(NO FEE) DISC CODES 06 ASN/CHG PRMT ENG CERT DATE 04/20/01 LAST NOV DATE / / CONBILL( ) COMMENTS: MESSAGE: *** ENTER DATA FOR UPDATE *** Jon H. Laughter Donald J. Austin Thomas P. Welbourn James D. Chambless, Sr. Laughter, Austin and Associates, P.A. Engineering • Planning • Land Surveying 131 FOURTH AVENUE EAST HENDERSONVILLE, NORTH CAROLINA 28792 LETTER OF TRANSMITTAL 'Vp� . Kerr T. Stevens, P.E., Director North Carolina Department of Environment and Natural Resources Division of Water Quality Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (828)692-9089 Fax (828) 693-8822 WATS 1-800-858-LAND April 5, 2001 DIV. OF WATER QUALITY DIRECTOR'S OFFICE Project. Ridgeview Condominium HOA 18a' Fairway Sewer Extension at Kenmure Wastewater Collection System Extension Henderson County LAA Job No. 00-218 Application Preliminary New Submittal Revision Final Submittal Information You Requested Additional Info. Requested For Approval As -Built Submittal Completion Certification Request To Start Construction For Your Files ] Other o Fast Track • Permit No. WQ0019064 Dear Mr. Stevens, Please find the following items enclosed as required by Division of Water Quality regulations for "Fast Track" projects for the aforementioned project: 1.) One (1) copy of Record Drawings . 2.) A Completion Certification. WATERGU��0t4 APR 2 U 2001 NOOsmilre® pelmltung Kerr T. Stevens, Director NCDENR-DWQ Non -Discharge Permitting Unit Page 2; April 5, 2001 Ridgeview Condominium HOA 18s` Fairway Sewer Extension at Kenmure Wastewater Collection System Extension Henderson County LAA Job No. 00-218 If additional information is required or should you have any questions, please phone me at (828) 692-9089 or (800) 858-LAND. Facsimile (828) 693-8822. Respectfully submitted, LAUGHTER, AUSTIN AND ASSOCIATES, P.A. ��A U� Jon H. Laughter, P.E. /jde Enclosures: YES Prcj. status: FinaLlCompletion Action: Acceptance ce: Project file RECEIVED WAnRQUMMSEMN Crny documents\sewerU.TR00218cert APR G u zuol Non•DWorge Penn(t6ng Ilina ironment -ces — - -- — - <--lity Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director May 10, 2001 CITY OF HENDERSONVILLE EZRA ALLMAN P O BOX 1760 HENDERSONVILLE NC 28793 1� NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Permit No. WQ00 Carriage Sewer -Public Henderson County Dear Mr. Allman: The Division's Non -Discharge Permitting Unit has received your signed and sealed certification with record drawings. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. Please note that the record drawings will be forwarded to the Asheville Regional Office and have not been reviewed. If a review is conducted, you will be notified of any non -conformity with the Minimum Design Criteria. If it would be helpful to discuss this matter further, I would suggest that you contact the Water Quality Regional Supervisor at the Asheville Regional Office at (828) 251-6208. Sincerely, Thelma Williams cc: Asheville Regional Office, Water Quality Section Central Files Mountain Engineering Co 1617 Mail Service.Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper July 16, 1999 ENGINEER'S CERTIFICATION Partial % Final I, JOHN 11. JETER , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, CARRIAGE PARK -Section 13 Rendergrnyi i 1 e, Henderson for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, the certificate of covera ;e the North Carolina Gravity Sewer Minimum Design Manual, and other supporting materials. ���.�`�H CARp •' •, Signature Date 3-29-01 =`•� SEAL !•s 20180 ftlNEB �'Z- 4KER JE, Registration No. 20180 The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of the "Record Drawings" (i.e., as -constructed plans) of the wastewater collection system This project shall not be considered complete and allowed to operate until this Engineer's Certification and the "Record Drawings" plans have been submitted. Any wastewater .flow made tributary to the wastewater collection system prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-05RECEIVED. 35 WA7> a Of 1ni rtv c��110N APR -V ` 1 Non-Dischetge PertniWng- inaDivision cf Water Qrt V hereby aclliowledges receipt and acca Mce of this Engiu=� Certification 3 NPDES FACILITY AND PERMIT DATA 04/20/01 15:36:08 TRXID 5OU KEY WQ0016955 FACILITY APPLYING FOR PERMIT APP/PERMIT FEE-$ 400.00 REGION PP'TA TY NAME> HENDERSONVILLE, CITY-CARRIAGEI COUNTY> HENDERSON 01 RESS: MAILING (REQUIRED) ENGINEER: MOUNTAIN ENGINEERING CO. STREET: PO BOX 1760 STREET: PO BOX 66 CITY: HENDERSONVILLE 5T NC ZIP 28793 CITY: FLAT ROCK ST NC ZIP 28731 TELEPHONE 828 697 3063 TELEPHONE: 828 697 9573 STATE CONTACT> SERG FACILITY CONTACT EZRA ALLMAN TYPE OF PROJECT> SEWERS -PUBLIC LAT: LONG: DATE APP RCVD 06/03/99 N=NEW,M=MODIFICATION,R=REISSUE> N DATE ACKNOWLEDGED 06/11/99 DATE REVIEWED / / RETURN DATE REG COMM REQS 06/11/99 DATE DENIED / / NPDES #- NCO025534 REG COMM RCVD 07/07/99 DATE RETURNED / / TRIB Q .0014 MGD ADD INFO REQS / / OT AG CON REQS / / TRIB DATE- 07/16/99 ADD INFO RCVD / / OT AG CON RCVD END STAT APP P 09/01/99 DATE ISSUED 07/16/99 DATE EXPIRE FEE CODE( 7)1=(>1MGD),2=(>IOKGD),3=(>1KGD),4=(<1KGD+SF),5=(S>300A),6=(S<=300A), 7=((SENDEL),8=(SEDEL),9=(CLREC), 0=(NO FEE) DISC CODES 01 ASN/CHG PRMT ENG CERT DATE 04/20/01 LAST NOV DATE / / CONBILL( ) COMMENTS: SECTION XIII MESSAGE: *** DATA MODIFIED SUCCESSFULLY *** I MOUNTAIN ENGINEERING COMPANY CIVIL ENGINEERING + SITE PLANNING P.O. BOX 66 Flat Rock, N.C. 28731 (828) 697-9573 Kerr T. Stevens, Director C. Department of Environment and Natural Resources Division of Water Quality I PVrmits and Engineering Unit Post Office Box 29535 $aleigh, North Carolina 27626-0535 Re: Permit No. WQ0016955 City of Hendersonville Carriage Park - Section 13 Wastewater Collection System Henderson County Dear Mr. Stevens: 30 March 2001 APR 1 2 2001 DIV. OF WATER QUALITY DIRECTOR'S OFFICE To the best of my knowledge, the above referenced project has been completed according to the approved plans and permit. In compliance with the permit, I am enclosing the Engineer's Certification as well as one(l) copy of the "As Built" (Record) drawings. Sincerely yours, John B. J ter, P. E. cc: Ezra W. Allman, City of Hendersonville RECEIVED Dale A. Hamlin, Carriage Park WkTFRr$tarTYq;:VT10N APu NorfDisftrge Pennit6ng PATTERSON & PATTERSON PAUL PATTERSON WILLIAM PATTERSON PROFESSIONAL ENGINEER PROFESSIONAL LAND SURVEYOR P.O. BOX 1189 HENDERSONVILLE, NC28793-1189 1-828-692-6629 (FEL & FAX) MEMORANDUM August 30, 2001 North Carolina Division of Water Quality Water Quality Section Permits and Engineering Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Project: FINAL COMPLETION CERTIFICATION Chadwick Square Wastewater Collection System City of Hendersonville Henderson County NCDENR Permit No. WQ0016310 S60 / 8 Dated - June 23, 2000 _..; Dear Sir/Madam: Please find attached herewith, a Final Completion Certification for the Wastewater Collection System to provide sewer service Chadwick Square located on the west side of said Greenville Highway at the intersection of said highway and Chadwick Avenue, with the installation of approximately 551 linear feet (total) of eight (8) inch diameter PVC/Ductile Iron sewer line, six (6) manholes, and sanitary sewer laterals to serve sixty-seven apartments and two office buildings. I am hereby requesting approval of this portion of project from your office, as well as the Henderson County Utilities Department. Should you have any questions or comments, please feel free to call. Thanks in advance for your cooperation in this matter. Sincerely, Paul Patterson, P.E. cc: File:00-03-06-ENG Ezra Allman, Director @ City of Hendersonville Water & Sewer Dept. c:\lotus\work\wordpro\wsspecs\certs\chadslt.lwp ENGINEERING - SURVEYING - PLANNING