HomeMy WebLinkAbout20061838 Ver 1_More Info Letter_20061208O~~F W ATF9 pG Michael F. Easley, Governor ~ William G. Ross Jr., Secretary ~~-- North Carolina Department of Environment and Natural Resources ~ ~ - (~ ^~' Alan W. Klimek, P.E. Director I9ivision of Water Quality December 8, 2006 DWQ EXP No. 06-1838 Chatham County CERTIFIED MAIL: RETURN RECEIPT REQUESTED Charles E. Lewis 9308 Foxburrow Court Raleigh, NC 27613 Project Name: Cedar Mountain Subdivision REQUEST FOR MORE INFORMATION-EXPRESS REVIEW PROGRAM Dear Mr. Lewis: On December 7, 2006, the Division of Water Quality (DWQ) received your application fora 401 Water Quality Certification. The DWQ has determined that this information is incomplete. Please provide the additional information requested below in order to prevent denial of your application as required by 15A NCAC 2H .0506: 1. Please provide full-size maps and site development plans as described in the PCN Addendum. 2. Stormwater Management: The impervious surface cover appears to have been calculated based on the entire 162-acre site. This project appears to be a phased subdivision project and that the proposed development depicted on the plans is considerably smaller than 162 acres. Please recalculate the impervious surface area based on the area of the tract you are developing. DWQ does require engineered stormwater management for pockets of high density even if the overall impervious surface is below the threshold. Please also include a breakdown of any high-density areas (e.g., the northeast corner of the site appears to be high density). 3. The average stream widths indicated on the PCN application appear to be unusually wide. Please recheck average stream width as compared with culvert design to ensure adequate sizing. 4. There appears to be a discrepancy between the stream impact lengths on the PCN form, and the stream impact detail sheets. Please include any proposed riprap at the inlets and outlets of the culverts in the stream impact length and that the amount of impacts noted and/or depicted on the plans match the amounts listed within the PCN application. Please respond within five (5) days of the date of this letter by sending five (5) sets of this information in writing. This letter only addresses the application review and does not authorize any impacts to wetlands, waters or protected buffers. 401 Oversight I Express Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-17861 FAX 919-733-689311ntemet: htto://h2o.enr.state.nc.us/ncwetlands N ne Carolina ~tura!!y An Equal OpportunitylAffirmativeAaion Employer- 50% Recycled/10% Post Consumer Paper Cedar Mountain Subdivision Page 2 of 2 December 8, 2006 Please call Cynthia Van Der Wiele at (919) 715-3473 or Lia Myott at (919) 733-9502 if you have any questions regarding or would like to set up a meeting to discuss this matter. Sincerely, Cyndi Karoly, 401 Oversight/Express Review Permitting Unit CBKlcvdw/lem cc: DWQ Raleigh Regional Office File copy Central Files Scott Mitchell, B. Scott Mitchell Environmental Consulting, 602 E. Academy St., Suite 105, Fuquay-Varina, NC 27526