April 8, 2011
Wilson County
NCDWQ Project No. 20110318
Bridge 3 on SR 1634
TIP No. B-4328
APPROVAL of 401 WATER QUALITY CERTIFICATION and NEUSE BUFFER AUTHORIZATION, with
ADDITIONAL CONDITIONS
Dr. Gregory J. Thorpe, Environmental Management Director
NCDOT PDEA
1598 Mail Service Center
Raleigh, NC 27699-1598
Dear Dr. Thorpe:
You have our approval, in accordance with the conditions listed below, for the following impacts for the purpose of
replacing Bridge 3 in Wilson County:
Wetland Imnacts in the Neuse River Rasin
Site Permanent Fill ac Mechanized Clearing ac Total Wetland Impact ac
1 0.01 0.01 0.02
Total 0.01 0.01 0.02
Total Wetland Impact for Project: 0.02 acres.
Neuse Riparian Buffer Impacts
Site Zone 1 minus = Zone 1 Zone 1 Buffer r Zone 2 minus = Zone 2 Zone 2 Buffer
Impact Wetlands Buffers (not Mitigation Impact Wetlands Buffers Mitigation
(sq ft) in Zone 1 wetlands) Required (sq ft) in Zone 2 - (not Required (using
Oil ft) (sq ft) (using 3:1 ratio) (sq ft) wetlands) 1.5:1 ratio)
s ft
1 4185 0 4185 N/A @ 1258 0 1258 N/A
Totals 4185 0 4185 0 u 1258 0 1258 0
* n/a = Total for Site is less than 1/3 acre and 150 linear feet of impact, no mitigation required
Total Buffer Impact for Project: 5,443 square feet.. _ .. - .. , - -
The project shall be constructed in accordance with your application dated received April 6, 2011. After reviewing your
application, we have decided that these impacts are covered by General Water Quality Certification Number 3820. This
certification corresponds to the General Permit 31 issued by the Corps of Engineers. This approval is also valid for the
Neuse Riparian Buffer Rules (I 5A NCAC 2B.0233). In addition, you should acquire any other federal, state or local
permits before you proceed with your project including (but not limited to) Sediment and Erosion Control, Non-
Discharge and Water Supply Watershed regulations. This approval will expire with the accompanying 404 permit.
Transportation Permitting Unit
Wetlands & Stormwater Branch
1650 Mail Service Center, Raleigh, North Carolina 27699-1650
Phone: 919b07-63991 FAX: 919-807-6494
Internet: http:llh2o.encstate.ne.us/ncwetlandsl
NorthCarolina
Natimally
An Equal Opportunity \ Affirmative Action Employer
This approval is valid solely for the purpose and design described in your application (unless modified below). Should
your project change, you must notify the NCDWQ and submit a new application. If the property is sold, the new owner
must be given a copy of this Certification and approval letter, and is thereby responsible for complying with all the
conditions. If total wetland fills for this project (now or in the future) exceed one acre, or of total impacts to streams
(now or in the future) exceed 150 linear feet, compensatory mitigation may be required as described in 15A NCAC 2H
.0506 (h) (6) and (7). Additional buffer impacts may require compensatory mitigation as described in 15A
NCAC.0242(9). For this approval to remain valid, you must adhere to the conditions listed in the attached-
certification(s) and any additional conditions listed below.
Conditions of Certification:
1. The post-construction removal of any temporary bridge structures must return the project site to its preconstruction
contours and elevations. The impacted areas shall be revegetated with appropriate native species.
2. Strict adherence to the most recent version of NCDOT's Best Management Practices For Bridge Demolition and
Removal approved by the US Army Corps of Engineers is a condition of the 401 Water Quality Certification.
3. Bridge deck drains shall not discharge into the stream. Stormwater shall be directed across the bridge and pre-
treated through site-appropriate means (grassed swales, pre-formed scour holes, vegetated buffers, etc.) before entering
the stream. Please refer to the most current version of Stormwater Best Management Practices.
4. Bridge piles and bents shall be constructed using driven piles (hammer or vibratory) or drilled shaft construction
methods. More specifically, jetting or other methods of pile driving are prohibited without prior written approval from
NCDWQ first.
5. No drill slurry or water that has been in contact with uncured concrete shall be allowed to enter surface waters. This
water shall be captured, treated, and disposed of properly.
6. All pile driving or drilling activities shall be enclosed in turbidity curtains unless otherwise approved by NCDWQ in
this certification.
7. All bridge construction shall be performed from the existing bridge, temporary work bridges, temporary causeways,
or floating or sunken barges. If work conditions require barges, they shall be floated into position and then sunk. The
barges shall not be sunk and then dragged into position. Under no circumstances should barges be dragged along the
bottom of the surface water.
8. All Stormwater runoff shall be directed as sheetflow through stream buffers at nonerosive velocities, unless otherwise
approved by this certification.
9. All riparian buffers impacted by the placement of temporary fill or clearing activities shall be restored to the
preconstruction contours and revegetated. Maintained buffers shall be permanently revegetated with non-woody species
by the end of the growing season following completion of construction. For the purpose of this condition, maintained
buffer areas are defined as areas within the transportation corridor that will be subject to regular NCDOT maintenance
activities including mowing. The area with non-maintained buffers shall be permanently revegetated with native woody
species before the next growing season following completion of construction.
10. Pursuant to NCAC 15A 26.0233(6), sediment and erosion control devices shall not be placed in Zone I of any
,Neuse Buffer without prior approval by NCDWQ. At this time, NCDWQ hasapproved-no sediment ,and erosion,
control devices in Zone 1, outside of the approved project impacts, anywhere on this project. Moreover, sediment and
erosion control devices shall be allowed in Zone 2 of the buffers provided that Zone I is not compromised and that
discharge is released as diffuse flow.
11. If concrete is used during construction, a dry work area shall be maintained to prevent direct contact between curing
concrete and stream water. Water that inadvertently contacts uncured concrete shall not be discharged to surface waters
due to the potential for elevated pH and possible aquatic life and fish kills.
12. During the construction of the project, no staging of equipment of any kind is permitted in waters of the U.S., or
protected riparian buffers.
13. The dimension, pattern and profile of the stream above and below the crossing shall not be modified. Disturbed
Floodplains and streams shall be restored to natural geomorphic conditions.
14. The use of rip-rap above the Normal High Water Mark shall be minimized. Any rip-rap placed for stream
stabilization shall be placed in stream channels in such a manner that it does not impede aquatic life passage.
15. The Permittee shall ensure that the final design drawings adhere to the permit and to the permit drawings submitted
for approval.
16. All work in or adjacent to stream waters shall be conducted in a dry work area. Approved BMP measures from the
most current version of NCDOT Construction and Maintenance Activities manual such as sandbags, rock berms,
cofferdams and other diversion structures shall be used to prevent excavation in flowing water.
17. Heavy equipment shall be operated from the banks rather than in the stream channel in order to minimize
sedimentation and reduce the introduction of other pollutants into the stream.
18. All mechanized equipment operated near surface waters must be regularly inspected and maintained to prevent
contamination of stream waters from fuels, lubricants, hydraulic fluids, or other toxic materials.
19. No rock, sand or other materials shall be dredged from the stream channel except where authorized by this
certification.
20. Discharging hydroseed mixtures and washing out hydroseeders and other equipment in or adjacent to surface waters
is prohibited.
21. The permittee and its authorized agents shall conduct its activities in a manner consistent with State water quality
standards (including any requirements resulting from compliance with §303(d) of the Clean Water Act) and any other
appropriate requirements of State and Federal law. If NCDWQ determines that such standards or laws are not being
met (including the failure to sustain a designated or achieved use) or that State or federal law is being violated, or that
further conditions are necessary to assure compliance, NCDWQ may reevaluate and modify this certification.
22. All fill slopes located in jurisdictional wetlands shall be placed at slopes no flatter than 3:1, unless otherwise
authorized by this certification..
23. A copy of this Water Quality Certification shall be maintained on the construction site at all times. In addition, the
Water Quality Certification and all subsequent modifications, if any, shall be maintained with the Division Engineer and
the on-site project manager.
24. The outside buffer, wetland or water boundary located within the construction corridor approved by this
authorization shall be clearly marked by highly visible fencing prior to any land disturbing activities. Impacts to areas
within the fencing are prohibited unless otherwise authorized by this certification.
25. The issuance of this certification does not exempt the Permittee from complying with any and all statutes, rules,
regulations, or ordinances that may be imposed by other government agencies (i.e. local, state, and federal) having
jurisdiction, including but not limited to applicable buffer rules, stormwater management rules, soil erosion and
sedimentation control requirements, etc.
26. The Permittee shall report any violations of this certification to the Division of Water Quality within 24 hours of
discovery.: ..., ...._;,
27. Upon completion of the project (including any impacts at associated borrow or waste sites), the NCDOT Division
Engineer shall complete and return the enclosed "Certification of Completion Form" to notify NCDWQ when all work
included in the 401 Certification has been completed.
28. There shall be no excavation from, or waste disposal into, jurisdictional wetlands or waters associated with this
permit without appropriate modification. Should waste or borrow sites, or access roads to waste or borrow sites, be
located in wetlands or streams, compensatory mitigation will be required since that is a direct impact from road
construction activities.
29. Native riparian vegetation (i.e., trees and shrubs native to your geographic region) must be reestablished within the
construction limits of the project by the end of the growing season following completion of construction.
30. Erosion and sediment control practices must be in full compliance with all specifications governing the proper
design, installation and operation and maintenance of such Best Managemenr Practices in order to protect surface waters
standards:
a. The erosion and sediment control measures for the project must be designed, installed, operated, and
maintained in accordance with the most recent version of the North Carolina Sediment and Erosion
Control Pldnnirig-arid Design Manual.
b. The design, installation, operation, and maintenance of the sediment and erosion control measures must be
such that they equal, or exceed, the requirements specified in the most recent version of the North
Carolina Sediment and Erosion Control Manual. The devices shall be maintained on all construction
sites, borrow sites, and waste pile (spoil) projects, including contractor-owned or leased borrow pits
associated with the project.
C. For.borrow pit sites, the erosion and sediment control measures must be designed, installed, operated, and
maintained in accordance with the most recent version of the North Carolina Surface Mining Manual.
d. The reclamation measures and implementation must comply with the reclamation in accordance with the
requirements of the Sedimentation Pollution Control Act.
31. Sediment and erosion control measures shall not be placed in wetlands or waters unless otherwise approved by this
Certification.
If you wish to contest any statement in the attached Certification you must file a petition for an administrative hearing.
You may obtain the petition form from the office of Administrative hearings. You must file the petition with the office
of Administrative Hearings within sixty (60) days of receipt of this notice. A petition is considered filed when it is
received in the office of Administrative Hearings during normal office hours. The Office of Administrative Hearings
accepts filings Monday through Friday between the hours of 8:00am and 5:00pm, except for official state holidays. The
original and one (1) copy of the petition must be filed with the Office of Administrative Hearings.
The petition may be faxed-provided the original and one copy of the document is received by the Office of
Administrative Hearings within five (5) business days following the faxed transmission.
The mailing address for the Office of Administrative Hearings is:
Office of Administrative Hearings
6714 Mail Service Center
Raleigh, NC 27699-6714
Telephone: (919)-733-2698, Facsimile: (919)-733-3478
A copy of the petition must also be served on DENR as follows:
Ms. Mary Penny Thompson, General Counsel
Department of Environment and Natural Resources
1601 Mail Service Center
Raleigh, NC 27699-1601
This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have
any questions, please contact Rob Ridings at 919-807-6403.
Sincerely,
1Coleen H. Sullins
Director
Cc: Chad Co'-ins, Division 4 Environmental Officer
Tom Steffens, US Army Corps of Engineers, Washington Field Office
Travis Wilson, NC Wildlife Resources Commission
Chris Underwood, NCDOT. NEU
File Copy-