Loading...
HomeMy WebLinkAbout20210067 Ver 1_Pre-Filing Meeting Information_2021011113+47.55CL CULVERTRT SIDECL CULVERTLT SIDEEXISTING STREAM BEDELEVATION NEAR BANK90.17PROPOSED 80LF OF 48" CORRUGATED METAL DIVERSION PIPE (INV. 91.17)PROPOSED OPEN DIVERSION LINED WITH GEOTEXTILE AND CLASS B RIP RAP(SEE DETAIL A-A)INLET PROTECTION RIP RAPW/ GEOTEXTILEELEV. 97.1714'-818"16'-378"5'-858"9'-1134"88'-412"105°ELEV. 99.16AAEXISTING DITCHEARTH MATERIALRIP RAP TO BE PLACED AFTERCONSTRUCTION OF CULVERT2:1ELEV. 90.17EXISTINGGROUNDELEV.97.17VARIES (6' MIN.)1'ELEV. 91.17SANFORDCONTRACTORSSANFORD CONTRACTORS, INC.628 ROCKY FORK CHURCH ROADSANFORD, NC 27332(919) 775-7882 TELE(919) 775-3406 FAXJOBDESCRIPTIONSHEET NO. OF CALC. BY CHECKED BY DATESCALE10-1285 - LENOIR COUNTY CULVERTCWBNOT TO SCALE1/6/2111PROPOSED TEMPORARY DIVERSIONNOTES:·ALL DIMENSIONS AND ELEVATIONS SHOWN AREAPPROXIMATE.·ALL EXCAVATION AND RIP RAP PLACEMENT WILLBE COMPLETED BEHIND TURBIDITY CURTAIN.·DIVERSION PIPE LOCATION IS APPROXIMATE.·APPROXIMATELY 2,000 SF OF AREA IMPACTED.·OPEN DIVERSION DITCH WILL REMAIN IN FINALCONDITION. RIP RAP DENOTED IN HATCHED AREAWILL BE ADDED AT CULVERT COMPLETIONDETAIL A-A