Loading...
HomeMy WebLinkAboutNC0021962_Compliance Evaluation Inspection_20201221ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Jim Utke, Terminal Manager CITGO Petroleum Corporation Post Office Box 58 Paw Creek, North Carolina 28130 Dear Mr. Utke: NORTH CAROLINA Environmental Quality December 21, 2020 Subject: Compliance Evaluation Inspection CITGO — Charlotte Terminal NPDES Permit No. NCO021962 Mecklenburg County Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on December 15, 2020, by Mr. Wes Bell of this Office. Please inform the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding a copy of the enclosed report. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell@ncdenr.gov. Sincerely, EA DocuSigned by: �r.�n.aty H Nuft for F161 FB69A2D84A3... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, DEQ Enclosure: Inspection Report D-;� North Carolina Department of Environmental Quality I Division of Water Resources EMooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 NOR7H ORROLINA i kmrl l m EnNromi W uwi` /`� 704.663.1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO021962 I11 121 20/12/15 I17 18I � I 19 I s I 201 I 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 2.0 701d I 71 I„ I 72 I r., I 71 I 74 79 I I I I I I I80 L—I ty L-1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:15AM 20/12/15 15/09/01 Charlotte Terminal 7600 Mount Holly Rd Exit Time/Date Permit Expiration Date Charlotte NC 28214 10:50AM 20/12/15 20/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Jim Utke//704-392-3236 / Robert Edward Durham/ORC/704-392-3236/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Michael Santee,36th St Delaware River Box 655 Pennsauken NJ 08110/EHSS Manager/856-952-0390/8569632587 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Wes Bell Signed by: DWR/MRO WQ/704-663-1699 Ext.2192/ 12/18/2020 2 re& E�D`,','�96D90=437 ... Signature of M 'r�tWYA'Reviewer Agency/Office/Phone and Fax Numbers Date [e�44" Andrew Pit H P WR/MRO WQ/704-663-1699 Ext.2180/ 12.21.2020 F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO021962 I11 12I 20/12/15 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO021962 Owner -Facility: Charlotte Terminal Inspection Date: 12/15/2020 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The Division received the facility's permit renewal application on 12/3/19. The last compliance evaluation inspection at this facility was performed by Mecklenburg Countv Stormwater Services staff on 8/29/18. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ Page# 3 Permit: NCO021962 Inspection Date: 12/15/2020 Owner -Facility: Charlotte Terminal Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Comment: The records reviewed durina the insDection were oraanized and well maintained. Discharae Monitoring Reports (eDMRs) were reviewed for the period September 2019 through Octobel 2020. No effluent limit violations were reported and all monitoring frequencies were correct. The ORC and staff must ensure that the times for effluent sampling (at outfall), preservation (transported samples put on ice) and sample relinquishment are properly documented. Please note that all effluent samples must be preserved (chemically, on ice, etc.) within 15-minutes of sample collection (Reference: 40 CFR 136.3 Table II). In addition, the ORC and staff must ensure to report all future effluent total recoverable phenols down to the contracted lab's reporting limit (40 uq/L) and not the method detection limit (8.3 ug/L). The contracted lab should be contacted to obtain a lower reporting limit (5 uq/L) for this parameter. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment: The on -site personnel (ORC and Backup ORC) collect all effluent samples. Pace Analytical Services. Inc. has been contracted to Derform all effluent analvses. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ 0 ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: The subject permit requires effluent grab samples Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Page# 4 Permit: NCO021962 Owner -Facility: Charlotte Terminal Inspection Date: 12/15/2020 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Comment: NPDES facilities appeared to be properly operated and well maintained. The secondary containment dikes and valves, storage tanks, etc. are inspected daily (minimum) during all business days. Any water (stormwater runoff, wash down water, etc.) from the truck loading rack is collected and pumped into a storage tank for off -site disposal. Zebra Environmental & Industrial Services has been contracted for the removal and disposal (approximately 2-3 times per year) of the storage tank contents. Although no effluent total suspended solids and turbidity violations have been reported, this Office recommends the facility staff to apply a gravel/rock cover to the small areas of exposed dirt observed within the secondary containment structure. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ❑ ❑ 0 ❑ Is flow meter calibrated annually? ❑ ❑ 0 ❑ Is the flow meter operational? ❑ ❑ 0 ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Effluent flows are based on a previously determined instantaneous flow rate and duration of discharge. The facility staff should re -verify the flow rate to ensure accurate flow values are being measured/reported. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ 0 ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The facility was not discharging at the time of the inspection. The manually operated discharge valve was secured with a lock. The accumulated water inside the dike (near the discharge outfall) appeared clear with no petroleum sheens. Page# 5