Loading...
HomeMy WebLinkAboutNC0036684_Inspection_20191008United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO036684 I11 121 19/10/08 I17 18I � I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:30AM 19/10/08 16/01/01 Bent Creek WWTP 3 Donnybrook Ct Exit Time/Date Permit Expiration Date Asheville NC 28806 11:30AM 19/10/08 20/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted James T Highley,PO Box 240908 Charlotte NC 282240908H704-525-7990/7045258174 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement Operations & Maintenar 0 Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs DWR/ARO WQ/828-296-4500 Ext.4653/ G. Landon Davidson DWR/ARO WQ/828-296-4500/ Daniel J Boss DWR/ARO WQ/828-296-4658/ Timothy H Heim DWR/ARO WQ/828-296-4665/ Mikal Willmer DWR/Division of Water Qua lity/828-296-4686/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) NCO036684 I11 12I 19/10/08 117 18 i s i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) ARO staff met with Mike Abel to set up ARO sampling equipment. Samples were split from the facility's sampler. The ARO sample results are as follows: BOD — 5.8 mg/I Fecal Coliform - <35 col/100ml TSS — 6.2 mg/I Observations of the WWTP were: Structural concrete decay remains a concern. The ORC stated management has considered a new WWTP at this site but is unlikely in the next year. However, discussions with an adjacent landowner are ongoing. Clarifier blanket was high. The ORC wasted while we were onsite. Upon departure the second day turbid water started coming into the WWTP from a utility operation that was performing directional boring in the vicinity and hit a sewerline. Page# Permit: NCO036684 Inspection Date: 10/08/2019 Owner -Facility: Bent Creek WWTP Inspection Type: Compliance Sampling Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: As noted in previous inspection, structural concrete decay remains a concern. Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Type of aeration system Is the basin free of dead spots? E ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/I) ❑ ❑ ❑ OT,IT, —Taiu Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ 0 ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Page# 3 Permit: NCO036684 Owner -Facility: Bent Creek WWTP Inspection Date: 10/08/2019 Inspection Type: Compliance Sampling Secondary Clarifier Yes No NA NE Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) ❑ 0 ❑ ❑ Comment: Blanket was high. ORC performed WAS. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Page# 4 Permit: NC0036684 Inspection Date: 10/08/2019 Effluent Sampling Comment: See summary for split sample results. Owner -Facility: Bent Creek WWTP Inspection Type: Compliance Sampling Yes No NA NE Page#