HomeMy WebLinkAbout20202009 Ver 1_LINE 333 TYPICAL 8IN RETROFIT DESIGN (1) (1)_20210111'I G
p
s
A
SEE NOTE 1
8"
EXISTING GAS LINE
DETAIL
SCALE: NTS 8" SINGLE FITTING REPLACEMENT
NOTES:
1. TRANSITION FITTING SHALL BE MACHINED TO MATCH
EXISTING 8" PIPE WITH NEW 8" X 0.322 AT PIPE PER
PNG SPECIFICATION DM-ST-2340.
PIPE SPECIFICATIONS:
ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS.
TRANSITION
NOTES:
EXISTING GAS LINE
3R 450
3R 450 VERT. BEND
1. MINIMUM LENGTH 2' 0".
2. TRANSITION FITTING SHALL BE MACHINED TO MATCH
EXISTING 8" PIPE WITH NEW 8" X 0.322 WT PIPE PER
PNG SPECIFICATION DM—ST-2340.
PIPE SPECIFICATIONS:
ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS.
NorthStar Energy Services, Inc.NC Engineering License F-0626
11712 Statesville Rd, Huntersville, NIC 28078
PROFESSIONAL ENG/ARCHSTAMP
3R - ELBOW
SEGMENTABLE
SEE NOTE 1
EXISTING GAS LINE
SEE NOTE 1
3R - ELBOW
SEGMENTABLE
NOTES:
EXISTING GAS LINE
DETAIL 2
SCALE: NTS 8" STACKED FITTING REPLACEMENT
811
SEE NOTE 2
1. TRANSITION FITTING SHALL BE MACHINED TO MATCH
EXISTING 8" PIPE WITH NEW 8" X 0.322 WT PIPE PER
PNG SPECIFICATION DM-ST-2340.
2. MINIMUM LENGTH 3'-0", FIELD DETERMINED
MEASUREMENT.
PIPE SPECIFICATIONS:
ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS.
EXISTING/PROPOSED
UTILITY
2'-0" 51-011
MIN. MIN.
FINISH GRADE
3R 450 VERT. BEND
3R 450
EXISTING GAS LINE
3R - ELBOW
SEGMENTABLE
SEE NOTE 1
EXISTING GAS LINE
TRANSITION
DETAIL 3
SCNTS
ALE- 8„ BOXED SECTION REPLACEMENT UNDER EXISTING UTILITY
SEE NOTE 1
ORIGINAL GAS LINE
FINISH GRADE
MIN. COVER, SEE TABLE
PROPOSED
GAS LINE
EXISTING
UTILITY
PROPOSED
GAS LINE
MIN. 2' CLEARANCE
MIN. 2' CLEARANCE
DETAIL 4
SCALE: NTS PROPOSED GAS LINE CROSSING OF EXISTING UTILITY
PIPE CLASSIFICATI❑N
MIN, COVER
TRANSMISSI❑N MAIN
3'-6"
DISTRIBUTI❑N MAIN
2'-6"
SERVICE MAIN
1'-6"
DETAIL 5
SCALE: NTS 8" TRANSITION ADDTION
DIFFERENT WALL THICKNESS TO ORIGINAL GAS LINE
AInTr-C`.
1. TRANSITION FITTING SHALL BE MACHINED TO MATCH
EXISTING 8" PIPE TO NEWER 8" PIPE WT PER PNG
SPECIFICATION DM—ST-2340.
PIPE SPECIFICATIONS:
ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS.
ORIGINAL GAS LINE
SEE NOTE 1
PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY
PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001
NO. DATE REVISION(S) DESCRIPTION
A 11/4/2020 ISSUE FOR 30% REVIEW
B 01/06/2021 ISSUE FOR 90% REVIEW
BY CHK JAPPD DESCRIPTION
OB MC RP AREA CODE 2500
SM MC RP ACCOUNT NUMBER 10700
PROJECT NUMBER 0232884
DRAWING BY SM
STATION ID -
CHECKER INITIALS MC
APPROVALS
DATE
INITIALS
REGIONAL
NIA
N/A
ENGINEER
DATE
INITIALS
MGR TECH
NIA
N/A
REC &STD
DATE
INITIALS
PRINCIPAL
NIA
N/A
ENGINEER
Arm%, DUKE Piedmont
ENERGY, Natural Gas
COPYRIGHT 2018
LINE 333- RETROFIT
TYPICAL 8" RETROFIT DESIGNS
ARCH DALE, NC
High Point Resource Center - High Point, North Carolina
90% NOT FOR
CONSTRUCTION
REF. DWG(S)
SHEET(S) 5 OF 6 DWG SCALE NTS
DWG DATE 05/07/2020 SUPERSEDED
DRAWING NUMBER REVISION
PNG -M-333-0001003 B
DISCIPLINE / RESOURCE CENTER / LINE NUMBER