HomeMy WebLinkAbout20202009 Ver 1_LINE 333 TYPICAL 8IN RETROFIT DESIGN (1) (1)_20210111'I G p s A SEE NOTE 1 8" EXISTING GAS LINE DETAIL SCALE: NTS 8" SINGLE FITTING REPLACEMENT NOTES: 1. TRANSITION FITTING SHALL BE MACHINED TO MATCH EXISTING 8" PIPE WITH NEW 8" X 0.322 AT PIPE PER PNG SPECIFICATION DM-ST-2340. PIPE SPECIFICATIONS: ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS. TRANSITION NOTES: EXISTING GAS LINE 3R 450 3R 450 VERT. BEND 1. MINIMUM LENGTH 2' 0". 2. TRANSITION FITTING SHALL BE MACHINED TO MATCH EXISTING 8" PIPE WITH NEW 8" X 0.322 WT PIPE PER PNG SPECIFICATION DM—ST-2340. PIPE SPECIFICATIONS: ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS. NorthStar Energy Services, Inc.NC Engineering License F-0626 11712 Statesville Rd, Huntersville, NIC 28078 PROFESSIONAL ENG/ARCHSTAMP 3R - ELBOW SEGMENTABLE SEE NOTE 1 EXISTING GAS LINE SEE NOTE 1 3R - ELBOW SEGMENTABLE NOTES: EXISTING GAS LINE DETAIL 2 SCALE: NTS 8" STACKED FITTING REPLACEMENT 811 SEE NOTE 2 1. TRANSITION FITTING SHALL BE MACHINED TO MATCH EXISTING 8" PIPE WITH NEW 8" X 0.322 WT PIPE PER PNG SPECIFICATION DM-ST-2340. 2. MINIMUM LENGTH 3'-0", FIELD DETERMINED MEASUREMENT. PIPE SPECIFICATIONS: ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS. EXISTING/PROPOSED UTILITY 2'-0" 51-011 MIN. MIN. FINISH GRADE 3R 450 VERT. BEND 3R 450 EXISTING GAS LINE 3R - ELBOW SEGMENTABLE SEE NOTE 1 EXISTING GAS LINE TRANSITION DETAIL 3 SCNTS ALE- 8„ BOXED SECTION REPLACEMENT UNDER EXISTING UTILITY SEE NOTE 1 ORIGINAL GAS LINE FINISH GRADE MIN. COVER, SEE TABLE PROPOSED GAS LINE EXISTING UTILITY PROPOSED GAS LINE MIN. 2' CLEARANCE MIN. 2' CLEARANCE DETAIL 4 SCALE: NTS PROPOSED GAS LINE CROSSING OF EXISTING UTILITY PIPE CLASSIFICATI❑N MIN, COVER TRANSMISSI❑N MAIN 3'-6" DISTRIBUTI❑N MAIN 2'-6" SERVICE MAIN 1'-6" DETAIL 5 SCALE: NTS 8" TRANSITION ADDTION DIFFERENT WALL THICKNESS TO ORIGINAL GAS LINE AInTr-C`. 1. TRANSITION FITTING SHALL BE MACHINED TO MATCH EXISTING 8" PIPE TO NEWER 8" PIPE WT PER PNG SPECIFICATION DM—ST-2340. PIPE SPECIFICATIONS: ALL UNDERGROUND PIPING SHALL BE COATED PER PIEDMONT SPECIFICATIONS. ORIGINAL GAS LINE SEE NOTE 1 PROPRIETARY & CONFIDENTIAL ALL RIGHTS RESERVED * DO NOT SCALE THIS DRAWING * USE DIMENSIONS ONLY PIEDMONT'S NATURAL GAS FACILITY DRAWINGS ARE CONSIDERED CONFIDENTIAL (OM-1095) * DRAWING IS CURRENT ONLY THROUGH THE LATEST REVISED DATE * TO ENSURE THERE IS NO RISK OF INAPPROPRIATE DISCLOSURE ALL PREVIOUS PAPER COPIES OF THIS DRAWING MUST BE DESTROYED IN ACCORDANCE WITH RECORDS & INFO. MANAGEMENT (RIM) POLICY 1001 NO. DATE REVISION(S) DESCRIPTION A 11/4/2020 ISSUE FOR 30% REVIEW B 01/06/2021 ISSUE FOR 90% REVIEW BY CHK JAPPD DESCRIPTION OB MC RP AREA CODE 2500 SM MC RP ACCOUNT NUMBER 10700 PROJECT NUMBER 0232884 DRAWING BY SM STATION ID - CHECKER INITIALS MC APPROVALS DATE INITIALS REGIONAL NIA N/A ENGINEER DATE INITIALS MGR TECH NIA N/A REC &STD DATE INITIALS PRINCIPAL NIA N/A ENGINEER Arm%, DUKE Piedmont ENERGY, Natural Gas COPYRIGHT 2018 LINE 333- RETROFIT TYPICAL 8" RETROFIT DESIGNS ARCH DALE, NC High Point Resource Center - High Point, North Carolina 90% NOT FOR CONSTRUCTION REF. DWG(S) SHEET(S) 5 OF 6 DWG SCALE NTS DWG DATE 05/07/2020 SUPERSEDED DRAWING NUMBER REVISION PNG -M-333-0001003 B DISCIPLINE / RESOURCE CENTER / LINE NUMBER