Loading...
HomeMy WebLinkAbout20110041 Ver 1_More Info Letter_20110209~~~ w~~~ NCDETIR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary February 9, 2011 CERTIFIED MAIL: RETURN RECEIPT REQUESTED Cert. # 7010 0290 0001 5628 1831 Cox-Edwards Company, Inc. Mr. Scott Edwards, PE 1205 Parkway Drive Goldsboro, NC 27534 DWQ Project # 11-0041 Wayne County Subject Property: Phase XI Annexation Area, Pump Station Access and Force Main Neuse River Basin, Ut to Little River (NEU 06, 27-57(20.2); NSW, WS-IV) REQUEST FOR ADDITIONAL INFORMATION Dear Mr. Edwards: On January 13, 2011, the Division of Water Quality (DWQ) received your 401 application dated January 11, 2011 regarding your request to construct 4,760 linear feet of 12 foot wide access road and 12,000 linear feet of 8" force main sewer pipe. The DWQ has determined that your application is incomplete and/or provided inaccurate information as discussed below. The DWQ will require additional information in order to process your application to impact protected wetland, streams and/or buffers on the subject property. Therefore, unless we receive the additional information requested below, we will have to move toward denial of your application as required by 15A NCAC 2H .0506 and 2B .0233(8) and will place this project on hold as incomplete until we receive this additional information. Please provide the following information so that we may continue to review your project. Additional Information Requested: 1. It is required that plans show placement of culverts and other structures in waters, streams, and wetlands placed below the elevation of the streambed by one foot for all culverts with a diameter greater than 48 inches, and 20 percent of the culvert diameter for culverts having a diameter less than 48 inches, to allow low flow passage of water and aquatic life. North Carolina Division of Water Quality Internet: www.ncwaterqualit.Lorg 943 Washington Square Mall Phone: 252-946-6481 Washington, NC 27889 FAX 252-946-9215 An Equal Opportunity/Affirmative Action Employer - 50% Recycled110% Post Consumer Paper NorthCarolina ~aturall~ 2. It is necessary to show linear feet of culvert impacts and linear feet of riprap placed in stream for energy dissipation or scour protection on page 6, item (3.) Stream Impacts, on your PCN form. 3. It is necessary to illustrate, on plan drawings, installation of instream energy dissipaters or scour protection below streambed elevation as not to interfere with aquatic passage during low flow conditions. Please respond in writing to the DWQ within 30 days of receipt of this letter with the requested information. If we do not hear from you within 30 days, we will assume that you no longer want to pursue this project and we will consider the project as withdrawn. This letter only addresses the application review and does not authorize any impacts to wetlands, waters or protected buffers. Please be aware that any impacts requested within your application are not authorized (at this time) by the DWQ. Please call Roberto Scheller of the Washington Regional Office at 252-948-3940 or Ian McMillan of the DWQ Central Office at 919-733-1786 if you have any questions regarding or would like to set up a meeting to discuss this matter. Sincerely, ~o }fit-- Al Hodge Division of Water Quality Surface Water Protection Washington Regional Office cc: 401 Oversight/Express Permitting Unit William Wescott, USACE, Washington Regulatory Field Office File Copy Filename: 11-0041