HomeMy WebLinkAbout20110138 Ver 1_Application_2011020920E W ATF9O9 I f?@P N LR U
0o? w FEB 0 9 2011
OM-N41THiOAP
WET{ANIAMSM MY T RBRANCH
11 U108
Office Use Only:
Corps action ID no.
DWQ project no.
Form Version 1.3 Dec 10 2008
Pre-Construction Notification PCN Form
A. Applicant Information
1. Processing
1a. Type(s) of approval sought from the
Corps: non-reporting nationwide permit
®Section 404 Permit ? Section 10 Permit
1b. Specify Nationwide Permit (NWP) number: NWP 3 or General Permit (GP) number:
1c. Has the NWP or GP number been verified by the Corps? ? Yes ® No
1d. Type(s) of approval sought from the DWQ (check all that apply):
N 401 Water Quality Certification - Regular ? Non-404 Jurisdictional General Permit
? 401 Water Quality Certification - Express ? Riparian Buffer Authorization
le. Is this notification solely for the record
because written approval is not required? For the record only for DWQ 401
Certification:
® Yes ? No For the record only for Corps Permit:
® Yes ? No
1f. Is payment into a mitigation bank or in-lieu fee program proposed for mitigation
of impacts? If so, attach the acceptance letter from mitigation bank or in-lieu
fee program. ? Yes ® No
1g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h
below. ? Yes ® No
1h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ? Yes N No
2. Project Information
2a. Name of project: Proposed pipe repair to the outlet of a structure conveying an unnamed tributary to
Reedy Creek along SR 1509 (Warrenton-Embro Road)
2b. County: Warren
2c. Nearest municipality / town: Warrenton
2d. Subdivision name: N/A
2e. NCDOT only, T.I.P. or state
project no:
3. Owner Information
3a. Name(s) on Recorded Deed: NCDOT Division 5
3b. Deed Book and Page No. N/A
3c. Responsible Party (for LLC if
applicable): N/A
3d. Street address: 2612 N. Duke Street
3e. City, state, zip: Durham, NC 27704
3f. Telephone no.: (919)220-4600
3g. Fax no.: (919)560-3371
3h. Email address: wbowman(a)ncdot.gov
4. Applicant Information (if different from owner) N/A
5. Agent/Consultant Information (if applicable) N/A
Page 1 of 8
PCPV Form -Version 1.3 December 10, 2008 Version
y
B. Project Information and Prior Project History
1. Property Identification
1a. Property identification no. (tax PIN or parcel ID): N/A
1b. Coordinates (in decimal degrees):
Site: Latitude: 36.3828 Longitude: -78.0924
(DD.DDDDDD) (-DD.DDDDDD)
1c. Property size: < 0.01 acres
2. Surface Waters
2a. Name of nearest body of water (stream, river, etc.) to Reedy Creek
proposed project:
2b. Water Quality Classification of nearest receiving water: C NSW
2c. River basin: Tar-Pamlico
3. Project Description
3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this
application:
Two pipe segments from the outlet have disconnected. Site is surrounded b wooded land.
3b. List the total estimated acreage of all existing wetlands on the property:
NONE
3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property:
60ft (right-of-way to right-of-way)
3d. Explain the purpose of the proposed project: Pipe ends have fallen off. As a result the shoulder section and fill slope
have collapsed. In order to rebuild the shoulder and fill slope the pipe ends must be reset.
3e. Describe the overall project in detail, including the type of equipment to be used:
A backhoe and/or excavator will be used to lift out the disconnected pieces. Backfill of stone material will be used to prepare
the cross line bed and the pieces will be reset. The pipe pieces will be covered with suitable material and shoulder and slope
section over the pipe will be rebuilt. Filter fabric will be used surrounding the pipe end beneath rip rap armoring. Soil material
used to repair the shoulder will rest against the rock and area will be reve etated.
4. Jurisdictional Determinations
4a. Have jurisdictional wetland or stream determinations by the
Corps or State been requested or obtained for this property / ? Yes ®No ? Unknown
project (including all prior phases) in the past.
Comments: N/A
4b. If the Corps made the jurisdictional determination, what type
El Preliminary ? Final
of determination was made?
4c. If yes, who delineated the jurisdictional areas? Agency/Consultant Company: N/A
Name (if known): N/A Other: N/A
4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation.
N/A
5. Project History
5a. Have permits or certifications been requested or obtained for
? Yes ®No ? Unknown
this project (including all prior phases) in the past?
5b. If yes, explain in detail according to "help file" instructions.
N/A
r
r,
?f
l-
;J
AF
c
v
J
Page 2 of 8 t
PCN Form - Version 1.3 December 10, 2008 Version
6. Future Project Plans
6a. Is this a phased project? ? Yes ® No
6b. If yes, explain.
N/A
C. Proposed Impacts Inventory
1. Impacts Summary
la. Which sections were completed below for your project (check all that apply):
? Wetlands ® Streams - tributaries ® Buffers
? Open Waters ? Pond Construction
2. Wetland Impacts
If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted.
2a. 2b. 2c. 2d. 2e. 2f.
Wetland impact Type of jurisdiction
number - Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact
Permanent (P) or (if known) DWQ - non-404, other) (acres)
Temporary T
W1 ? P ? T N/A N/A ? Yes ? Corps N/A
? No ? DWQ
2g. Total Wetland Impacts: NONE
2h. Comments: N/A
3. Stream Impacts
If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this
question for all stream sites impacted.
3a. 3b. 3c. 3d. 3e. 3f. 3g.
Stream impact Type of impact Stream name Perennial Type of jurisdiction Average Impact
number - (PER) or (Corps - 404, 10 stream length
Permanent (P) or intermittent DWQ - non-404, width (linear
Temporary (T) (INT)? other) (feet) feet)
Site 1 ? P ®T UT to Reedy ®PER ®Corps <_ 24ft
Stream 1 dewatering Creek Anderson ? INT ® DWQ Eft within ROW
Swamp Creek
Site 1 ®P ? T UT to Reedy ®PER ®Corps s 15ft
Stream 1 rip rap armoring Creek Anderson ? INT ® DWQ 6ft concurrent
Swamp Creek
3h. Total stream and tributary impacts < 24ft
3i. Comments: 24ft = 1 Oft at outlet and 14ft at inlet of exposed stream within right-of-way. 36ft =existing pipe length.
4. Open Water Impacts
If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of
the U.S. then individually list all open water impacts below.
4a. 4b. 4c. 4d. 4e.
Open water Name of
impact number- waterbody Type of impact Waterbody type Area of impact (acres)
Permanent (P) or (if applicable)
Temporary T
01 ? P ? T N/A N/A N/A N/A
4f. Total open water impacts NONE
4g. Comments: N/A
Page 3 of 8
PCN Form -Version 1.3 December 10, 2008 Version
5. Pond or Lake Construction
If and or lake construction proposed, then complete the chart below.
5a. 5b. 5c. 5d. 5e.
Wetland Impacts (acres) Stream Impacts (feet) Upland
Pond ID Proposed use or purpose of (acres)
number pond
Flooded Filled Excavated Flooded Filled Excavated Flooded
P1 N/A N/A N/A N/A N/A N/A N/A N/A
P2
5f. Total NONE NONE NONE NONE NONE NONE NONE
5g. Comments: N/A
5h. Is a dam high hazard permit required?
? Yes ®No If yes, permit ID no: N/A
5i. Expected pond surface area (acres): N/A
5j. Size of pond watershed (acres): N/A
5k. Method of construction: N/A
6. Buffer Impacts (for DWQ)
If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts
below. If an impacts require mitigation, then you MUST fill out Section D of this form.
6a.
? Neuse ?Tor-Pamlico ? Other:
Project is in which protected basin? ? Catawba ? Randleman
6b. 6c. 6d. 6e. 6f. 6g.
Buffer impact
number - Reason for Buffer Zone 1 impact Zone 2 impact
Permanent (P) or impact Stream name mitigation (square feet) (square feet)
Temporary T required?
Site ? P ? T UT to ? Yes
Buffer Impact 1 Rip rap
Reedy Creek
? No 0 SF 0 SF
6h. Total buffer impacts 0 SF O SF
6i. Comments: All work performed within existing transportation facility.
D. Impact Justification and Mitigation
1. Avoidance and Minimization
1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project.
This is a repair site and will require minimal disturbance. Site will be dewatered and the reset pipe end armored with rip rap
underlined with filter fabric for long term stabilization.
1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques.
Sediment and erosion control Best Management Practices for protection of surface waters will be enforced during project
construction.
Page 4 of 8
PCN Form -Version 1.3 December 10, 2008 Version
2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State
2a . Does the project require Compensatory Mitigation for
impacts to Waters of the U.S. or Waters of the State? ? Yes ® No
2b. If yes, mitigation is required by (check all that apply): ? DWQ ? Corps
2c.
If yes, which mitigation option will be used for this project? ? Mitigation bank
? Payment to in-lieu fee program
? Permittee Responsible Mitigation
3. Complete if Using a Mitigation Bank
3a. Name of Mitigation Bank: N/A
3b. Credits Purchased (attach receipt and letter) Type N/A Quantity N/A
3c. Comments: N/A
4. Complete if Making a Payment to In-lieu Fee Program
4a. Approval letter from in-lieu fee program is attached. ? Yes
41b. Stream mitigation requested: N/A linear feet
4c. If using stream mitigation, stream temperature: ? warm ? cool ?cold
4d. Buffer mitigation requested (DWQ only): N/A square feet
4e. Riparian wetland mitigation requested: N/A acres
4f. Non-riparian wetland mitigation requested: N/A acres
4g. Coastal (tidal) wetland mitigation requested: N/A acres
4h. Comments: N/A
5. Complete if Using a Permittee Responsible Mitigation Plan
5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. N/A
6. Buffer Mitigation (State Regulated Riparian Buffer Rules) - required by DWQ
6a. Will the project result in an impact within a protected riparian buffer that requires
buffer mitigation? ? Yes ®No
61b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the
amount of mitigation required.
Zone 6c.
Reason for impact 6d.
Total impact
(square feet)
Multiplier 6e.
Required mitigation
(square feet)
Zone 1 N/A N/A 3 (2 for Catawba) N/A
Zone 2 N/A N/A 1.5 N/A
6f. Total buffer mitigation required: NONE
6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank,
permittee responsible riparian buffer restoration, payment into an approved in-lieu fee fund). N/A
6h. Comments: N/A
Page 5 of 8
PCN Form - Version 1.3 December 10, 2008 Version
E. Stormwater Management and Diffuse Flow Plan (required by DWQ)
1. Diffuse Flow Plan
1a. Does the project include or is it adjacent to protected riparian buffers identified ? Yes ® No
within one of the NC Riparian Buffer Protection Rules?
1b. If yes, then is a diffuse flow plan included? If no, explain why.
? Yes ? No
Comments: N/A
2. Stormwater Management Plan
2a. What is the overall percent imperviousness of this project? N/A
2b. Does this project require a Stormwater Management Plan? ? Yes ® No
2c. If this project DOES NOT require a Stormwater Management Plan, explain why: NCDOT state Permit No. NCS000250
2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: N/A
? Certified Local Government
2e. Who will be responsible for the review of the Stormwater Management Plan? ? DWQ Stormwater Program
? DWQ 401 Unit
3. Certified Local Government Stormwater Review
3a. In which local government's jurisdiction is this project? Warren County
? Phase II
? NSW
3b. Which of the following locally-implemented stormwater management programs ? USMP
apply (check all that apply): ? Water Supply Watershed
? Other:
3c. Has the approved Stormwater Management Plan with proof of approval been ? Yes ? No
attached? N/A
4. DWQ Stormwater Program Review
? Coastal counties
? HOW
4a. Which of the following state-implemented stormwater management programs apply ? ORW
(check all that apply): N/A ? Session Law 2006-246
? Other:
4b. Has the approved Stormwater Management Plan with proof of approval been
? Yes ? No
attached? N/A
5. DWQ 401 Unit Stormwater Review
5a. Does the Stormwater Management Plan meet the appropriate requirements? N/A ? Yes ? No
5b . Have all of the 401 Unit submittal requirements been met? N/A ? Yes ? No
Page 6 of 8
PCN Form - Version 1.3 December 10, 2008 Version
F. Supplementary Information
1. Environmental Documentation (DWQ Requirement)
la. Does the project involve an expenditure of public (federal/state/local) funds or the ® Yes ? No
use of public (federal/state) land?
1b. If you answered "yes" to the above, does the project require preparation of an
environmental document pursuant to the requirements of the National or State ? Yes ® No
(North Carolina) Environmental Policy Act (NEPA/SEPA)?
1c. If you answered "yes" to the above, has the document review been finalized by the
State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval
letter.) ? Yes ? No
Comments: N/A
2. Violations (DWQ Requirement)
2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated
Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, ? Yes ® No
or Riparian Buffer Rules (15A NCAC 2B .0200)?
2b. Is this an after-the-fact permit application? ? Yes ® No
2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): N/A
3. Cumulative Impacts (DWQ Requirement)
3a. Will this project (based on past and reasonably anticipated future impacts) result in ? Yes No
additional development, which could impact nearby downstream water quality?
3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the
most recent DWQ policy. If you answered "no," provide a short narrative description.
N/A
4. Sewage Disposal (DWQ Requirement)
4a. Clearly detail the ultimate treatment methods and disposition (non-discharge or discha rge) of wastewater generated from
the proposed project, or available capacity of the subject facility.
N/A
Page 7 of 8
PCN Form -Verson 1.3 December 10, 2008 Version
5. Endangered Species and Designated Critical Habitat (Corps Requirement)
5a. Will this project occur in or near an area with federally protected species or ? Yes ® No
habitat?
51b. Have you checked with the USFWS concerning Endangered Species Act ? Yes ®No
impacts?
?
Raleigh
5c. If yes, indicate the USFWS Field Office you have contacted. ill
? A
h
ev
s
e
5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical
Habitat? Biologists from NCDOT O.N.E. has visited this site and rendered a biological conclusion of "No Effect"
http://www.fws.gov/nc-es/es/countyfr.htmi and NC Natural Heritage Program Database, Element Occurrences
6. Essential Fish Habitat (Corps Requirement)
6a. Will this project occur in or near an area designated as essential fish ? Yes ® No
habitat?
6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat?
hftp://ocean.floridamarine.org/efh coral/ims/viewer.htm
7. Historic or Prehistoric Cultural Resources (Corps Requirement)
7a. Will this project occur in or near an area that the state, federal or tribal
governments have designated as having historic or cultural preservation ? Yes ® No
status (e.g., National Historic Trust designation or properties significant in
North Carolina history and archaeology)?
7b. What data sources did you use to determine whether your site would impact historic or archeological resources?
HPO's historic layer using GIS ArcView database
8. Flood Zone Designation (Corps Requirement)
8a. Will this project occur in a FEMA-designated 100-year floodplain? ? Yes ® No
8b. If yes, explain how project meets FEMA requirements: N/A
8c. What source(s) did you use to make the floodplain determination? http://www.ncfloodmaps.com/
J. W. Bowman, P.E. 02108/11
Applicant/Agent's Printed Name Applicant/Agent's Signatur
(Agent's signature Is valid only if an authorization let from the applicant Date
Is provided,)
Page 8 of 8
PCN Form -Version 1.3 December 10, 2008 Version
t
Ridings, Rob
From: Ridings, Rob
Sent: Wednesday, February 09, 2011 12:15 PM
To: Montague, Heather W
Subject: RE: Non-reporting NWP 3/WQC 3687 Pipe Repair on SR 1509 (Warrenton-Embro Road) in
Warren County
Heather,
I agree this can be covered by the GC 3687. Proceed as you describe here.
Thanks,
Rob
-----Original Message-----
From: Montague, Heather W
Sent: Wednesday, February 09, 2011 12:00 PM
To: Alsmeyer, Eric C SAW; Ridings, Rob
Cc: Phipps, Dawn
Subject: Non-reporting NWP 3/WQC 3687 Pipe Repair on SR 1509 (Warrenton-Embro Road) in Warren
County
Rob and Eric-
Warren County Maintenance has a disconnected pipe site on SR 1509 (Warrenton-Embro Road) in
Warren County (see attached map). There is currently a collapsed shoulder section above the
outlet of this structure, which is a safety concern. Eight feet of a 36ft pipe will be reset.
The area will then be backfilled to provide an adequate shoulder and slope section. Rip rap
will be installed underlined with filter fabric for long term stability surrounding the mouth
of the pipe extension as well as along the stream banks as needed up to 15 linear feet. The
exposed stream length of 24ft out to the ROW limits if needed will be temporarily dewatered
in order to maintain a dry work area. The stream at this site is subject to the Tar-Pamlico
River Riparian Buffer Rules, but since activity will be limited the existing transportation
facility, no buffer impacts will result and a written buffer authorization would not be
necessary. This pipe repair work should meet the conditions for working under a non-reporting
NWP 3 and WQC No. 3687.
NCDOT biologists, Logan Williams and Karen Lynch, screened this site for protected mussels
and have provided the following conclusion: Site was visited on February 2, 2011. The
unnamed tributary to Reedy Creek originates 0.9 miles upstream of the crossing on SR 1509.
From the crossing the UT flows about another mile to Reedy Creek, which then flows
approximately 14 miles to the confluence with Little Fishing Creek. There are no records of
dwarf wedgemussel or Tar River spinymussel in Reedy Creek. Also this Ut. is too small at the
crossing to support mussels. It looks like repairing this pipe at the crossing would be
beneficial so that erosion would be reduced at this site. This work would have No Effect on
either the dwarf wedgemussel or Tar River spinymussel.
For maintenance sites such as this one, NCDOT Division 5 has a procedure in place to provide
our construction crews with print outs of the general conditions along with a letter head
cover sheet explaining the intent to operate under a non-reporting permit as long as all
applicable conditions are meet. Oversight from both the Environmental Staff and REU Field
Operations Unit will ensure compliance with the permit conditions are met and that standard
BMPs are followed. Attached to this email is a courtesy PCN for your files along with site
maps and a construction plan. This work was scheduled to begin within the next several weeks.
1
-Heather Montague
DIV 5 Env Specialist
(252)492-0111 office
(919)691-1596 cell
Email correspondence to and from this sender is subject to the N.C. Public Records Law and
may be disclosed to third parties.
2
o
Z 1 c° o. 3 ?
w
lV,
M
p .?
3 -
. 3
? A
A
?I n
h
A
y
1
? Z
J
O
W
13
d
'd y
S 3
O N
? u=
s
s
°
w
i
0
N
I
J
i
i
9
ci
0
I ?
?L
? I
I, ^
a
r?
A
??gg
C
G sr. _ •.?
l V j
O r O? Q7 U \ ?? / I+ `? 11
3150
Creek
l i