HomeMy WebLinkAboutSW3201002_500 - send original - SuppEZ - sealed_20210106SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
INFORMATION EL
1 Project Name 7-11 Long Ferry Road
2 Project Area (ac) 4.1
3 Coastal Wetland Area (ac) 0
4 Surface Water Area (ac) 0
5 Is this project High or Low Density? High
6 Does this project use an off -site SCM? No
COMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided (feet)
N/A
8
Will the vegetated setback remain vegetated?
N/A
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)?
N/A
10
Is streambank stabilization proposed on this project?
No
MBER AND TYPE
11
Infiltration System
12
Bioretention Cell
13
Wet Pond
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
1
17
Rainwater Harvesting (RWH)
18
Green Roof
19
Level Spreader -Filter Strip (LS-FS)
20
Disconnected Impervious Surface (DIS)
21
Treatment Swale
22
Dry Pond
23
StormFilter
24
Silva Cell
25
Bayfilter
26
Filterra
FORMS LOADED
SIGNER CERTIFICATION
27
Name and Title:
Jonathan Woodard, P.E., Project Engineer
28
Organization:
McAdams
29
Street address:
3430 Toringdon Way, Suite 110
30
City, State, Zip:
Charlotte, North Carolina 28277
31
Phone number(s):
704.527.0800
32
Email:
jwoodard@mcadamsco.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
Designer
`,w i lllrlrl'1''
�.�` CAR p 'vvy
'�.
SEAL
0491 8 -
'.•tip f NEF:: oQ-`;
.N' s' wp0 \�.
��11rlu�IJ�I�,
&111ure of Designer
J412=i
Date
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
1
3
Does this project have low density areas?
No
4
If so, number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
4
Type of SCM
Sand Filter
5
Total drainage area (sq ft)
176453
146,033
6
Onsite drainage area (sq ft
176453
140,637
7
Offsite drainage area (sq ft)
0
5,396
8
Total BUA in project (sq ft)
121036 sf
122430 sf
9
New BUA on subdivided lots (subject to permitting)
(sq ft)
121036 sf
10
New BUA not on subdivided lots (subject to
permitting) (so
121036 sf
122430 sf
11
Offsite BUA (sq ft)
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft)
112204 sf
108202 sf
Sidewalk (sq ft)
4030 sf
4030 sf
Roof (sq ft)
4802 sf
4802 sf
Roadway (sq ft)
Future (sq ft)
Other, please specify in the comment box
below (sq ft)
13
New infiltrating permeable pavement on
subdivided lots (sq ft)
14
New infiltrating permeable pavement not on
Isubdivided lots (sq ft)
15
Existing BUA that will remain (not subject to
permitting) (sq ft)
16
Existing BUA that is already permitted (sq ft)
17
Existing BUA that will be removed (sq ft)
11469 sf
11469 sf
18
Percent BUA
69%
84%
19
Design storm (inches)
na
V
20
Design volume of SCM (cu ft)
na
6838 cf
21
Calculation method for design volume
nA
Simple Method
ADDITIONAL INFORMATION
122
Please use this space to provide any additional information about the
drainage area(s):
SAND FILTER
1
Drainage area number
1 to SCM
2
Minimum required treatment volume cu ft
6838 sf
GENERAL MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
161
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM designed by an NC licensedprofessional?
I Yes
SAND FILTER
MDC FROM 02H .1056
18
SHWT elevation (fmsl)
-15
19
Type of sand filter (open or closed)
Open
20
If closed, will the filter will be pre -cast or pour -in -place?
21
If closed, top of grate elevation (fmsl)
22
Is this sand filter designed to attenuate peak flows?
No
Sediment Chamber
23
Volume that can be retained in the sediment chamber (cubic feet)
4236 cf
24
Will there be a permanent pool in the sediment chamber?
No
25
Bottom of the sediment chamber fmsl
703.00
26
Area of the sediment chamber (square feet)
1899 sf
27
Physical depth of the sediment chamber inches
24 in
28
Ponding depth in the sediment chamber, above any permanent pool
inches
15 in
291
Elevation of top of weir between chambers (fmsl)
705
Sand Chamber
30
Volume that can be retained in the sand chamber cubic feet
4447 cf
31
Bottom of the sand chamber (fmsl)
703.00
32
Area of the sand chamber (square feet)
1831 sf
33
Physical depth of the sand chamber (inches)
24 in
34
Ponding depth in the sand chamber, above the sand surface
inches
15 in
351
Elevation of the bypass device (fmsl)
705
36
Type of bypass device
Riser
37
Mechanism for distributing flow over the sand surface
Diffusion over
earthen weir
38
Sand specification for sand chamber
See additional info
39
Depth above underdrain pipe (inches)
15 in minimum
40
Will the media be maintained to drain at least two inches per hour at
the sand surface?
Yes
41
Is at least one clean -out pipe provided at the low point of each
underdrain line?
Yes
42
Will clean -out pipes be capped?
Yes
TION
43 Please use this space to provide any additional information about the
sand filter(s):
Sand Specification: Clean AASHTO-M-6 or ASTM-C-33 Concrete Sand
Sand Filter 3 5:49 PM 1/5/2021