Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0042142_Application (FTSE)_20201130
_ R ,:_ Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: � �� l i L� Im he wnipleled h� MR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: Town of Fuquav-Varina (company, municipality. HOA, utility, etc.) 3. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ StateiCounty ® Municipal ❑ Other 3. Signature authority's name: Jay T. Mevers per 15A NCAC O>i _0106[ h 1 Title: Public Utilities Director 4. Applicant's mailing address: 134 N. Main Street NC Dept of Environmental Qtutttt City: Fuquay-Varina State: NC Zip: 27526- 5. Applicant's contact information: NOV 3 0 2020 Phone number: (919) 557-391 I Email Address: jmeyers c fuquay-varina.org [1. PROJECT INFORMATION: Raleigh Regional Uf�ic� 1. Project name: The Crossings - Infrastructure 3. Application: Project status: ® Proposed (New Permit) ❑ Existing Permit, Project If a modification, provide the existing permit number: WQ00... and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Wake 4. Approximate Coordinates (Decimal Degrees): Latitude: 35,596071 Longitude:-78.780021 5. Parcel ID (if applicable): 0667-41-8954 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer. Donald L. Curry License Number: 26970 Firm: The Curry Engineering Group, PLLC Mailing address: 205 S. Fuquav Ave. City: Fuquav-Varina State: NC Zip: 27526-2212 Phone number: (919) 51?-0849 Email Address: don a( cuMeneng;com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Terrible Creek WWTP Permit Number: NCO066516 Owner Name: Town of Fuquay-Varina V. RECEIVING DOWNSTREAM SEWER INFORMATION (ifdirferent than WWTF): I. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch 5�-stem.Wide Collection S%stem Pennit Number(O fif anglicable : WQCS",� Owner Name(s): 70w07 V9 FU tla1 ar tn`�� I FORM: FTA 04-16 Page l of VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes [:]No ®NfA ?. If the Applicant is a Developer of lots to be sold, has a Dcvelo -r1x�"ti nperational Agreement (FORM: DEV1 been attached? [:]Yes [-]No ©N'A $. If the Applicant is a HomeProperly Owners Association, has an Operational Agreement (FORM: H0A1 been attached" ❑ Yes ❑No ®N.'A .4. Origin of wastewater. (check all that apply): ❑ Residential Owned X❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ❑ Retail with food preparationiservice ❑ Hotel and/or Motels ❑ School ' preschool day care ❑ Medical Aental r veterinary facilities ❑ Swimming, Pool Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool Filter Backwash ® Businesses offices factories ❑ Nursing Home ❑ Other (Explain in Attachment) S. Nature of wastewater : 100 Residential % Dom estic:'Commercial % Commercial °'o Industrial (See I�6 NCAC 02T .0103t201) —Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NC. AC 0?T 0114tIl? ❑ Yes 2rNo If ves, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project. Establishment Type (see 021.01140 Daily Design Flow No. of Units Flow gall GPD gall GPD gal/ GPD gall GPD gall GPD gal/ GPD Total 1-0— GPD a See JJA NCAC 02T .01 I b 1) andig)7 for caveats to wastewater design Flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified fin table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NC'AC 021 _0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: Cl Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new now expected ® Other (Explain): This application if for the site infrastructure only. —Permitting, forapartments will follow. FORM: FTA 04-16 Page 2 of VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & 1IDC Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) I Length (feet) I Material 1 s 1 1 127 1 PVC (C900) Section 11 &_ III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (if Applicable) — 02T .0305 & MDC (Pump Stations. -force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -, 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T 05(h)( I t ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): r It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. I f the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .03Q5 & igi ❑X Yes ❑ No 15A NCAC 02T.0305(i) contains minimum separations that shall beprovided For sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches) IS inches Water mains (horizontal) 10 Feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 Feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet 5 feet 10 Feet Any building Foundation Any basement Top slope of embankment or cuts oft feet or more vertical height 10 Feet Drainages stems and interce for drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches I5A NCAC 02T.0305t �U contains alternatives where separations in O2T�Q cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications %vebpg= If noncompliance with 02T.0305(6 or lg)or lg). see Section X oFthis application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) [--]Yes ❑ No ®N'A Sec the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B _0200? ❑ Yes ❑ No ® N.'A This would include Trout Buffered Streams per I5A NCAC 213.0203 4. Does the project require coverage.'authorization under a 404 Nationwide or ® Yes [-]No individual permits or 401 Water Quality Certifications? Information can be obtained From the d &_Buffer permittin, F3ranch 5. Does project comply with 15A NCAC 02F,{}105(c]{6) (additional permits:'certifications)" ®Yes ❑ No Per 15A K.K. 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N'A i If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permitter or its representative at least once every sir -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02L the Minimum Design Criteria for the Permining of Pump Stations and Force Maisis fiatest version3, and the Gravity Sewer Minimum nc5io Criteria (latest version) as applicable? © Yes ❑ No If No, complete and submit the VariancelAlternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: ✓11a �Y _ attest that this application for _ (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000, as well as civil penalties up to S25,000 per violation. :t, �:,1rr�. North Carolina Professional Engineer's seal, signature, and date: A0001. .'.VJ10 i W l+l'L• ��4 ' f� ..j 3. Applicant's Certification per 15A NCAC 02T.0106(b): b bec, 04V �-?.BS _0f r . attest that this application for (Sighature'Authority'l name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and;`or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated_ I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to S25,000 per violation. Date: M ! o FORM: FTA 04-16 Page 5 of 5 CuxryENGINEERING November 24. 2020 NC Department of Environment Quality Division of Water Resources Ra.e g - Regional Dflice Water Quality Section 1628 Mad Servrce Center Raleigh, NC 27699-1628 I919I 791- 4200 RE: The Crossings - Infrastructure Sewer Fast Track Sanitary Sewer Application Cover Letter To Whom It May Concern, NC Dept of Environmental O"ali1N NOV 3 0 2020 RalcibhRegion d ()IfICL' Enclosed please find documentation, design data, applicat on fee and other resources necessary to review the Fast Track Applications for the public sanitary sewer system of The Crossings - Infrastructure development in Fuquay-Varina, NC. The project consists of the -,nfrastructure for a future apartment complex, which will be permitted at a future time. Construction of the sanitary sewer lines will connect to two existing public sewer lines at the center and west side of the property, wh ch feed to the Terrible Creek Waste Water Treatment Plant, The Crossings development s located at 775 N. Judd Parkway NE in Fuquay-Varina The property involved is tocated within the City of Fuquay-Varina, NC planning jurisdiction. The sanitary sewer system consists of 1127 feet of 8" PVC gravity sere ce conne--tang to existing pubic gravity main lines. There are nine )9) new manholes to be installed in the development - At the completion of construction, the system will be certified by a l censed profess ona'. engineer in accordance w-th NCOEQ and State and local regulations. Sincerely, -1141WLI Ed Loeffler, Project Manager T 19191 552-0849 205 5 Fuquay Avenue F 1919) 552-2043 Fuquay-Varina, NC 27526 F� Es r u+ o 10 \� \may CAR 00 P �OF \NATF,QQ State of North Carolina O G Department of Environment and Natural Resources c r Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE 06-13) Project Applicant Name: Town of Fuquay-Varina Project Name for which flow is being requested: The Crossings - Infrastructure More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Terrible Creek WWTP b. WWTP Facility Permit #: NCO066516 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 3.000 0.809 1.152 0.000 1.960 65.37% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) Design Pump Average Daily Station Firm Flow** (Name or Capacity,* (Firm / pf), Number) MGD MGD (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Plus Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pl) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Pagel of 6 FTSE 06-13 Certification Statement: I Jay T. Meyers, P.E., Public Utilities certify to the best of my knowledge that the addition of Director the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. ZOe Date Page 2 of 6 FTSE 06-13 tt.l� DOARNENT Or THE INTERIOR FUqU*Y-YARquADRANaLe MUSGS 76 imA u 1. GrOLOaca suw4v �41.' U$ Topo 1,1SITE LOCATION t. 4 FIN ZZ + LENQUAY-VANNA. I— K CuxLyENGINEERING TRANSMITTAL FORM TO: NC Dept. of Environmental Quality Div. of Water Resources Raleigh Regional Office Water Quality Section 1628 Mail Service Center Raleigh, NC 27699-1628 919-791-4200 SUBJECT: The Crossings - nfrastructure CURRY PROJECT NO: 2019-014 We are sending you the following items: COPIES ITEM 2 Application Forms 1 Check NC Dept of Environmental Ouality NOV 3 0 2020 Rzlcig(1 Regional Office DATE: November 24. 2020 SENT BY: Ed Loeffler DESCRIPTION East Track Sewer Application — The Crossings - Infrastructure FTSL 06-13 (Town of Fuquay-Varinal $480.00 Fee, Sewer Application These are transmitted as checked below: For information Approved as Noted — Revise and Resubmit As Requested Not Approved — Revise and Resubmit For Review and Comments For Record and File For Revision Submittal x For Approval For Recording Approved _ For Signature, then return to;__—__ REMARKS: Attached please find the signed Fast Track Sanitary Sewer Applications for the Crossing - Infrastru--ture property at 775 N. Judd Parkway NE in Fuquay-Vanna. Please contact me with any questions. Thank you. T 19191 552-0849 205 S. Fuquay Avenue F I9191 552-2043 Fuquay-Varina, NC 27526 /J�R`f E N G��\ Fp EST � un z 10 G \h' CAR00