HomeMy WebLinkAboutWQ0004797_Groundwater Monitoring Report November 2020_20201228Anchor QEA of North Carolina, PLLC ANCHOR 231 Haywood Street Asheville, North Carolina 28801 kZ QEA 828.281.3350 December 11, 2020 Tracy Wolfe Lassonde Pappas & Co., Inc. 125 Industrial Park Road Hendersonville, North Carolina 28792 Re: November 2020 Groundwater Sampling Event Clement Pappas NC, LLC Dear Ms. Wolfe, Anchor QEA of North Carolina, PLLC, is pleased to present the results of the November 2020 water quality monitoring event at the Clement Pappas NC, LLC (Clement Pappas) facility (the Site), located at 485 Brookside Camp Road in Hendersonville, North Carolina. The company that operates the facility rebranded to Lassonde Pappas & Company in 2016. However, for permitting purposes, the Hendersonville facility retains the Clement Pappas NC LLC name that is designated on the property deed. Groundwater Quality Anchor QEA performed the groundwater sampling event at the subject facility (the Site) on November 6, 2020. A Site location map is included in Figure 1. The groundwater sampling event was performed in accordance with North Carolina Department of Environmental Quality (DEQ) wastewater irrigation system permit No. WQ0004797 issued September 3, 2015, and renewed May 15, 2020 (referred to as the permit in this letter; effective September 1, 2020, and expires July 31, 2026). Anchor QEA used low -flow methods to purge and collect groundwater samples from six monitoring wells: MW-4, MW-5, MW-6, MW-7R, MW-8, and MW-9. Monitoring well MW-9 was installed April 14, 2015, to replace the previously damaged monitoring well MW-2R. Monitoring well MW-5 is an upgradient (background) monitoring well. The locations of the monitoring wells are shown in Figure 2. Anchor QEA submitted the groundwater samples to Pace Analytical Services, Inc., a North Carolina -certified laboratory, for analysis of the parameters specified in the permit, as follows: • Total organic carbon • Total nitrate • Chloride • Phosphorous • Fecal coliform • Total dissolved solids • Total ammonia • Volatile organic compounds (VOCs) by 6200 Groundwater Elevation Table 1 summarizes current and historical groundwater elevations from May 2018 to November 2020. Except for monitoring well MW-9, all monitoring well concrete pads and top -of -well casing elevations \\ashevillel\Asheville\Projects\Clement Pappas\Reports\2020\November\Files for review\20201211_November 2020 Groundwater Sampling Event Clement Pappas NC, LLC.docx December 11, 2020 Page 2 were surveyed by Wes Cole Land Surveying, PA, on November 21, 2012. Monitoring well MW-9 was surveyed by Wes Cole Land Surveying, PA, on May 29, 2015. The surveyed top -of -casing elevations are indicated in Table 1. Groundwater Analytical Results Table 2 summarizes the current and historical groundwater analytical results from May 2018 to November 2020. During the current sampling event, the parameters analyzed were within the groundwater standards provided in the permit,' except as follows: • The nitrate concentration exceeded the permit groundwater standard of 10 milligrams per liter (mg/L) in the sample collected from one monitoring well, MW-7R (13.0 mg/L) but has decreased significantly from the previous sampling event. The Title 15A, North Carolina Administrative Code [NCAC], Subchapter 2L, Section .0202 standard (2L standard) for total coliform is 1 colony -forming unit per 100 milliliters (1 CFU/100 mQ. There is not a specific permit limit or 2L standard for fecal coliform; however, total coliform includes fecal coliform. The following summarizes fecal coliform results from the groundwater monitoring wells: • Fecal coliform concentrations exceeded the 2L standard for total coliform in monitoring wells MW-5 (8.0 CFU/100 mQ, MW-6 (3.0 CFU/100 mQ, MW-8 (14.0 CFU/100 mQ, and MW-9 (16.0 CFU/100 mQ. • Fecal coliform was not detected at or above laboratory detection limits in the samples collected from monitoring wells MW-4 and MW-7R. The pH of the samples collected from MW-4 (5.30 standard units [SU]), MW-5 (5.65 SU), MW-6 (5.23 SU), MW-7R (5.54 SU), and MW-9 (4.93 SU) were below the groundwater standard range of 6.5 to 8.5 SU. The sample collected from the background monitoring well, MW-5, has a pH that is similar to the other groundwater monitoring wells. Volatile Organic Compounds Analytical results for VOCs, analyzed by U.S. Environmental Protection Agency Standard Method 620013, are presented in Table 2. In accordance with permit requirements, samples are analyzed for VOCs annually in November. No VOCs were detected at concentrations above the method detection limits in monitoring wells MW-4, MW-6, MW-7R, MW-8, or MW-9. VOC concentrations detected in MW-5 (the background monitoring well for the Site) are summarized as follows: Two VOCs (tetrachloroethene and trichloroethene) were detected in monitoring well MW-5. — Tetrachloroethene was detected at a concentration of 0.80 microgram per liter (pg/L), which exceeds its 2L standard (0.70 pg/L). Most of the groundwater standards are represented by the 2L standards, with the exception of nitrate and total organic carbon, which are set in the Wastewater Irrigation System Permit Number WQ0004797. December 11, 2020 Page 3 — Trichloroethene was detected at a concentration of 1.0 pg/L, which is below the permit groundwater standard (3.0 pg/L). — Concentrations of historically detected VOCs decreased during this sampling event to the lowest level since sampling began. Surface Water Quality Beginning in May 2017, Clement Pappas voluntarily collected surface water samples from Mud Creek, analyzing for the same constituents as those sampled in groundwater. The renewed permit issued in May 2020 and effective September 2020 requires semiannual sampling of the surface water locations. Sampling point SW-1 is located upstream of the Site, and sampling point SW-2 is located downstream of the Site. Sampling locations are shown in Figure 2. Surface Water Analytical Results Table 3 summarizes the historical and current surface water analytical results. For the November 2020 sampling event, no parameters were detected at concentrations above the associated 15A NCAC 2B surface water standards (2B standards). Since collection of surface water samples for all permit constituents began in May 2017, nitrate concentrations have been similar in SW-1 (upstream) and SW-2 (downstream). The fall 2020 sampling showed a similar relationship: upstream sample SW-1 showed a concentration of 0.71 mg/L, and downstream sample SW-2 showed 0.70 mg/L. The results for total organic carbon, chloride, total dissolved solids (TDS), ammonia, and total phosphorus were also similar for upstream and downstream samples, indicating the unlikelihood that the Site is impacting Mud Creek. The fecal coliform concentration was higher in the upstream sample SW-1 (145 CFU/100mL) than the downstream sample SW-2 (97 CFU/100mL). The Site irrigation fields have experienced significant flood events since over the last several years. The regular flooding of Mud Creek and its nutrient loading associated with runoff from agricultural fields upstream of the facility is suspected to have impacts on Site groundwater. Discussion Taking a proactive approach, in 2016 Clement Pappas contracted Nutter and Associates to analyze the overall health and performance of the land application system to determine ways to improve the longevity of the system while reducing the likelihood of impacts on groundwater. Based on this work, Clement Pappas has implemented the following activities: • To avoid introducing additional nitrogen into soils at the subject facility, Clement Pappas has implemented the practice of baling harvested fescue and removing it from the irrigation fields, instead of mowing it and allowing it to decompose. — Removing the harvested fescue should result in improved vegetative growth, which will allow the fescue to uptake additional available nitrogen. December 11, 2020 Page 4 — Additionally, it is expected that removing the harvested fescue will result in greater assimilation of nitrogen into facility soils and reduce the potential for nitrogen leaching. All of the samples collected during the November 2020 sampling event were below the permit standard for nitrate except for MW-7R; however, the nitrate concentration in MW-7R has decreased significantly since the last monitoring event. In accordance with the spray irrigation permit WQ0004797, Clement Pappas is required to submit the following to the DEQ by December 31, 2020 (on or before the last working day of the month following the sampling month): • Laboratory analytical reports and chain -of -custody forms (Attachment 1) • Well sampling logs and the equipment documentation and instrument calibration data sheet (Attachment 2) • DEQ GW-59A — Compliance Report Form (Attachment 3) • DEQ GW-59 — Groundwater Quality Monitoring: Compliance Report Form, for each monitoring well (Attachment 4) Anchor QEA proposes to complete the next scheduled groundwater and surface water sampling event in May 2021. If you have any questions or would like additional information, please do not hesitate to contact me at (828) 281-3350 orjverde@anchorqea.com. Sincerely, / _/ /J V" �_ Jennifer Verde Managing Engineer Attachments Table 1 Current and Historical Groundwater Elevation Measurements Table 2 Current and Historical Groundwater Analytical Results Table 3 Current and Historical Surface Water Analytical Results Figure 1 Site Location Map Figure 2 Site Plan Map Attachment 1 Laboratory Analytical Reports and Chain -of -Custody Forms Attachment 2 Well Sampling Logs and Instrument Calibration Data Sheet Attachment 3 DEQ GW-59A — Compliance Report Form Attachment 4 DEQ GW-59 — Groundwater Quality Monitoring: Compliance Report Forms Tables Table 1 Current and Historical Groundwater Elevation Measurements Well Identification MW-4 Screened Interval (ft bgs) Date Measured Depth to Groundwater Top -of- Casing Elevation Top -of -Casing Height Above Ground Surface Groundwater Elevation 5.0 - 15.0 05/02/2018 8.44 2063.77 2.43 2055.33 11/02/2018 8.00 2055.77 05/21/2019 8.49 2055.28 11/14/2019 8.82 2054.95 05/06/2020 7.98 2055.79 11/06/2020 8.02 2055.75 MW-5 9.0 - 19.0 05/02/2018 8.47 2085.60 3.00 2077.13 11/02/2018 8.23 2077.37 05/21/2019 8.57 2077.03 11/14/2019 8.90 2076.70 05/06/2020 8.28 2077.32 11/06/2020 8.90 2076.70 MW-6 5.0 - 10.0 05/02/2018 5.36 2061.17 3.00 2055.81 11/02/2018 5.03 2056.14 05/21/2019 5.53 2055.64 11/14/2019 5.59 2055.58 05/06/2020 5.41 2055.76 11/06/2020 5.33 2055.84 MW-7R 5.0 - 15.0 05/02/2018 10.99 2062.86 3.00 2051.87 11/02/2018 10.33 2052.53 05/21/2019 10.88 2051.98 11/14/2019 11.33 2051.53 05/06/2020 10.11 2052.75 11/06/2020 10.05 2052.81 MW-8 3.0 - 13.0 05/02/2018 9.39 2060.80 3.00 2051.41 11/02/2018 8.85 2051.95 05/21/2019 9.38 2051.42 11/14/2019 9.75 2051.05 05/06/2020 8.54 2052.26 11/06/2020 8.37 2052.43 MW-9 3.0 - 13.0 05/02/2018 5.07 2060.23 1.44 2055.16 11/02/2018 4.55 2055.68 05/21/2019 4.89 2055.34 11/14/2019 5.15 2055.08 05/06/2020 4.30 2055.93 11/06/2020 4.10 2056.13 November 2020 Groundwater Sampling Event Page 1 of 2 Clement Pappas, Hendersonville, North Carolina December 2020 Table 1 Current and Historical Groundwater Elevation Measurements Notes: Top -of -casing elevations: MW-5 through MW-8 top -of -casing elevations are based upon a survey by Hill and Associates Surveyors, dated January 10, 2002, through May 2012. MW-2R and MW-4 top -of -casing elevations are based upon differential level measurements made by Altamont Environmental, Inc., on June 26, 2006, through May 2012. The top -of - casing elevations for the monitoring wells were resurveyed on November 21, 2012, by Wes Cole Land Surveying. The top -of - casing elevations for MW-9 were surveyed on May 29, 2015, by Wes Cole Land Surveying. ft bgs: feet below ground surface Monitoring is performed in accordance with Permit No. WQ0004797 issued to Clement Pappas on May 15, 2020 and effective on September 1, 2020. November 2020 Groundwater Sampling Event Page 2 of 2 Clement Pappas, Hendersonville, North Carolina December 2020 Table 2 Current and Historical Groundwater Analytical Results Sample Name Sample Date O. ,� O p S F V O V £ 0 LL Z V) > O F V) O £ Q o s N- 0. F a a d 0 F a s i+ 77 O O H a a=i N S V_ V M a a0i L y V_ F M M L O VT i t O L O 0V (SU) (mg/L) (mg/L) (CFOs per 100 mL) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (Ng/L) (Ng/L) (Ng/L) (Ng/L) (Ng/L) (Ng/L) 2L Groundwater Standards 6.5 - 8.5 10 250 1 NL 500 500 7.5 NL 0.7 3 70 700 0.03 7 Groundwater Standards Provided in Permit No. WQ0004797 6.5 - 8.5 10 250 NL 10 250 500 7.5 NL 0.7 3 70 100 0.03 7 05/02/2018 5.86 3.0 10.0 <1.0 2.1 NA 167 <0.020 0.11 NR 11/02/2018 5.47 3.6 9.0 <10.0 0.48 NA 137 <0.10 0.070 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 MW-4 05/21/2019 5.81 3.0 11.3 <1.0 3.3 NA 170 <0.050 0.044J NR 11/14/2019 5.82 3.7 11 <1.0 0.42 NA 190 <0.10 <0.050 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/06/2020 5.70 2.3 7.6 <1.0 3.7 172 <0.10 <0.050 NR 11/06/2020 5.30 2.8 6.9 <1.0 0.73 148 <0.10 <0.050 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/02/2018 5.69 5.7 16.1 2.0 0.0 NA 90 <0.10 0.097 NR 11/02/2018 5.53 5.1 23.9 <10.0 <0.020 NA 86 <0.10 0.085 39.1 6.0 6.7 1 < 0.50 < 1.0 < 0.50 MW-5 05/21/2019 5.68 9.4 26.8 7.0 0.1 NA 91 <0.050 0.120 NR 11/14/2019 5.59 6.0 20.1 7.0 0.055 NA 202 <0.10 0.081 22.4 4.4 5.0 I < 0.50 < 1.0 < 0.50 05/06/2020 5.90 6.9 7.3 8.0 <0.040 116 <0.10 0.083 NR 11/06/2020 5.65 4.6 6.9 8.0 < 0.040 61.0 <0.10 0.060 0.80 1.0 < 0.50 1 < 0.50 < 1.0 < 0.50 05/02/2018 5.28 2.3 9.4 1.0 0.1 NA 81 <0.10 0.097 NR 11/02/2018 5.02 2.5 10.1 69.0 0.6 NA 88 <0.10 0.057 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 MW-6 05/21/2019 5.46 3.3 11.3 23.0 0.4 NA 78 <0.050 0.068 NR 11/14/2019 5.30 2.9 9.3 44.0 0.56 NA 342 <0.10 0.052 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/06/2020 5.38 2.0 9.7 3.0 1.1 96.0 <0.10 <0.050 NR 11/06/2020 5.23 2.6 12.5 3.0 3.2 139 <0.10 <0.050 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/02/2018 5.41 3.2 22.6 <2.0 15.5 NA 207 <0.10 0.320 NR 11/02/2018 5.48 5.3 20.2 <10.0 15.7 NA 243 <0.10 0.170 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 MW-7R 05/21/2019 5.58 3.0 29.0 <2.0 20.2 NA 234 <0.050 0.130 NR 11/14/2019 6.42 3.0 22.7 <2.0 17.1 NA 73 <0.10 0.084 < 0.50 < 0.50 < 0.50 < 0.50 < 1.0 < 0.50 05/06/2020 5.20 1.2 20.9 <1.0 21.5 219 219 <0.10 <0.050 NR 11/06/2020 5.54 1.7 17.8 <1.0 13.0 205 <0.10 <0.050 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/02/2018 6.74 10.8 12.9 <2.0 14.4 NA 548 <0.10 0.190 NR 11/02/2018 6.52 9.5 8.0 19.0 6.8 NA 351 <0.10 0.250 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 MW 8 05/21/2019 6.89 7.9 7.3 <10.0 6.2 NA 249 <0.050 0.290 NR 11/14/2019 6.71 7.7 7.2 2.0 1.2 NA 51 <0.10 0.10 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/06/2020 6.41 2.7 2.8 <1.0 3.6 139 <0.10 <0.050 NR 11/06/2020 6.34 2.8 2.3 14.0 2.4 127 <0.10 <0.050 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 05/02/2018 5.52 4.6 4.9 <2.0 0.6 NA 69 <0.10 0.370 NR 11/02/2018 5.11 8.4 5.8 <10.0 0.6 NA 88 <0.10 0.470 < 0.50 < 0.50 < 0.50 1 < 0.50 < 1.0 < 0.50 MW 9 05/21/2019 5.64 7.2 4.6 <10.0 0.2 NA 80 <0.050 0.230 NR 11/14/2019 5.57 6.1 5.4 <1.0 0.89 NA 56 <0.10 0.076 < 0.50 < 0.50 1 < 0.50 1 < 0.50 1 < 1.0 1 < 0.50 05/06/2020 5.52 5.9 1.8 <1.0 <0.040 68.0 <0.10 0.099 NR 11/06/2020 4.93 4.5 1.4 16.0 0.043 88.0 <0.10 1 0.095 < 0.50 1 < 0.50 1 < 0.50 1 < 0.50 1 < 1.0 1 < 0.50 Notes: 2L standards are set in North Carolina Administrative Code, Title 15A Subchapter 2L - Groundwater Classifications and Standards, Department of Environmental Quality (Amended April 1, 2013). Total organic carbon and nitrate standards are set in Wastewater Irrigation System Permit Number WQ0004797. There is no defined 2L standard for fecal coliform; therefore, the standard listed is for "total coliform." Bolded values indicate a concentration above the respective permit groundwater standard or outside the permit groundwater standard range. pH is analyzed by Anchor QEA of North Carolina, PLLC; NC lab certification number 5445 Monitoring is performed in accordance with Permit No. WQ0004797 issued to Clement Pappas on May 15, 2020 and effective on September 1, 2020. < indicates that the constituent concentration was not detected above the method detection limit pg/L: micrograms per liter CFU: coliform-forming unit J: The concentration is above the adjusted method detection limit and below the adjusted reporting limit and is therefore considered an estimate. mg/L: milligrams per liter mL: milliliter NL : No 2L standard exists. NR: not reported SU: standard unit November 2020 Groundwater Sampling Event Page 1 of 1 Clement Pappas, Hendersonville, North Carolina December 2020 Table 3 Current and Historical Surface Water Analytical Results G. C Oam L H 0 U L U = i O V 4V 0 LL U a Z �O > .a IA VI C Vf R 0 1= Q iA 3 L S iA 0 a (CFUs per Sample Name Sample Date (SU) (mg/L) (mg/L) 100 mL) (mg/L) (mg/L) (mg/L) (mg/L) 28 Standard 6.5 - 8.5 NL 230 200 NL NL NL NL 5/2/2018 6.88 1.5 4.8 53.0 0.74 54.0 <0.10 0.044 J 11/2/2018 6.28 2.9 5.1 780 0.72 54.0 <0.10 0.077 SW-1 5/21/2019 7.02 1.6 5.0 98.0 0.75 42.0 <0.050 0.067 (Upstream) 11/14/2019 6.76 1.9 5.3 118 0.83 57.0 <0.10 0.1 5/6/2020 7.20 1.6 4.6 290 0.76 49.0 <0.10 0.092 11/6/2020 5.83 1.6 4.4 145 0.71 56.0 <0.10 < 0.050 5/2/2018 6.98 1.4 4.4 118.0 0.72 51.0 0.052 J 0.045 J 11 /2/2018 7.08 2.9 4.6 940.0 0.75 53.0 0.099 J 0.076 SW-2 5/21/2019 6.99 1.6 4.9 200.0 0.76 47.0 <0.050 0.068 11/14/2019 7.01 1.9 5.4 127 0.82 83.0 <0.10 0.089 (Downstream) 5/6/2020 6.67 1.7 4.2 420 0.72 53.0 <0.10 <0.050 11/6/2020 6.19 1.6 4.4 97.0 0.70 59.0 <0.10 <0.050 Notes: 2B standard: surface water standard per North Carolina Administrative Code, Title 15A: Department of Environmental Quality, Subchapter 2B - Surface Water and Wetland Standards (last amended in September 2017), or the standard obtained from the U.S. Environmental Protection Agency Nationally Recommended Water Quality Criteria for Aquatic Life and Human Health. Bolded values indicate a concentration equal to or above the respective 2B standard or a value outside the 2B standard range. < indicates that the constituent concentration was not detected above the laboratory reporting limit Monitoring is performed in accordance with Permit No. WQ0004797 issued to Clement Pappas on May 15, 2020 and effective on September 1, 2020. CFU: coliform-forming unit J: The concentration is above the adjusted method detection limit and below the adjusted reporting limit and is therefore considered an estimate. mg/L: milligrams per liter mL: milliliters NL: No NC21L standard exists SU: standard unit November 2020 Groundwater Sampling Event Page 1 of 1 Clement Pappas, Hendersonville, North Carolina December 2020 Figures 1 4*411 03 I \ 1 ,, ;��? \�,�, ..:.: jl1\�\ ;a. _. �""• I� 11 / 1 /�// ii'�i= �\ �� \ 1 i i I l `\ `� -� \ ♦ \ _vv 1 1 1 ' /� I 1 / / / ,. �.I - / /�'i'- .\ \ i IIII \ vw\ \ w\ .. -// / I -. "^= v- s' \` I / \'• ��v. I\\\\\ kls. III L. //I!!///// \\\\ �� \\\ N. `\ \\\• _vv_•iv\\ \\\�11 //% / v/./ J','/ \� - \ \ __\ \ \\ / \ \ I / / /i N. / III \ 1 1 I ( \ \\ \_ \ I - l.. ll a l- I -_ ^. ';.IIII 1 Ij11\111\\\\\\ \����♦ \\\\\\ ` \`\`\-'\\_� ^\�\N\1 \\\\\\\\1\Il/ \ ( I I 1 I�/ / / //J I / \ \ \\.\\ ,\ \�-\\ \ \\ \\ \\\\\\\\\ \\ I/ / '� \i \. \\. / .I I I l/„_--- v / l/'^ \\: _ .. \ \ 1\♦\ . \ \� 1 \ \ \ �\ \ \ \ / I f I / / /•�' v / \:\\ \\ \\\�I.'� \\•\N \ \1 \`\\\ f \ \ \\ I I I I `���\\\\�� �\'.' \\\\\\\ .`\ \\IN v► *\\ \\ �:, •fi' \ - \I_�� <.'\\ \ l / I / I I'\ \`\` `\\\� \\ \ \\_/ 1 \ II 1 -v\ \\ \ \\\\\\ \\a. \\o\\\\"\\ -�1\ . 1 I 1j III i3 \�� �\`_.�/ \\\\\ \\\\\\\ �' `\U \\ \v,�' i ,ix.. / I'y-�� ., \ � 1 ��A+ 11 I I I I v � v \\ � 1.c N, \ \,. \`'/ / -�c\�: \\\\ / /. yr` / I// \\`\\\\v \_/ l 1/ /i \ \ \ a',.\\\ �v_�'�•�',;t'7 /F.. \.1 .\ 1 \ 1 11�1111\ I/ %"^�```�v`��-/ _li \\\ \\\\\ \\ \\\\\ N. \ \\\\\\ ��_� '-// /- \ \ v \ 1.\I k`\\ I 1.11j 1\\\\\\II It II r-N\\\�\� - l /// I I I \\ \ \a �l.+ \. �`I \\\\\\ \ \_� i% /// / / / I I IIS\\\ \ \\\ \ \\\�� i'�'i j/ \\ �\ \ +1 \ \\\`\ ,\ \11. \\\\\\\\\\\`\\\\\ I 11\1 1/�-=i/ //- --_''J 1 / 1 I .I.. / ��------ \ \ f 11 �.-`�� �v� �// 1\\ \\ !^ 1 \\ \ i--'�, /// / / , I I \ \\ \ \ \\\ \\\� ' / / \ \ 1 1 \\.,\\�\\\\\��\ v IIII I_/// / /\'? 111 �� I \ \•\\ 1, I I i I \\ ��� \\\ �.,_/% /^\ _ \\ I •�I. :.� \ I\ 1 � � J\� \\\`� \\\\� �\\� ��v_-=-',/%//j%/'�''� -_ A`.'"� yam! Y , `\_ \\ i�-_-- '- o. •I II fill If/ ( \\�� ///l /i / �-' / 1 I / 1 1 11 1 I I /, --;� � I III IIII I I11 / / --%// ,� � / / / I I _ 111 III I .\ //�I 1 r �� \� V A\ I I I I -1 1 // i � ,// /� I A � //ll II / / / �v / ♦_f��` , I \ III Iljl I\ II,I . J I / �;p �II� I111 I I/ / ,� �' / / _-_ �/, I // /-^_� / /,- \ \\\ I \ l 1 -/ 1 1 •I L, I III I \\ , / ,--.�11Y 1 1 1 �I I I /'v\ v -_1: /' �i-\ I \\ \\ / / I ; I I 111I�11 1 •- 1\\v `\� �'� \ I j 1 1 I I I f \� \ \\\\I\1\Ij\\\`_ r - ;;.,//' ,// / yz'77,41 '\-�'.\]\ 1\ \d\ \\�. -- ''.v i' i - ': I / / \\\\ I \ _ a' 1 I III Y-1 • '1 t�\\II\\\\\�� �_1 `��_-_�'�\ i-_-_v / i i � // �11 II 11 1 j // I/ , ., \\�\\ \\ \\ \ \ \ 111 11 • • � • 11•' " + - \ \x\ v^ v� iI IN v\ -� i j I l \\ 1 Y \\ \- \\ \\\\ \\\\ \`` •\\ /♦ ll 1 \ / . I � I .. \ \*` 'I \ I 1 \\\ I I / \ l l \ ♦/ I ll l `\ `\ \ \•. •\ \\ �� `\ / l I /. / / /r\\ I / I 1 I 1 \, /-•i.,\, .II .1 I 1I1 IN \\\ ��? C• �.�,� \\p,�,/// \` \` \�\'i'/ 11 1\ I I I \•. \\ `� i i�-\\\. - \ // . - �' ♦ /\ I \� - ♦ \ �_ 'i - i / / /i / IIII /. ♦\ \\ \\ \ \\\+s.. i'/ _ _ I \ \ ; \ �.,�• `\�-_ '' �+T st'i i�,�j%/ l l if �,�l,i / /^\1\ \1 •c`. \ •. -. - \ � ... � - , I \ 11 \ \ / �. \O iii/ I/ll 1:1\" / I I1. IN ' • \ �\ \ 1 � 1 �S \ \\ `�\�\ �-� yii' / / / I I 1 1 I 11., .I / 1 I l t - r • f\ 1 �.5�... �\`\�i ;� y�`+-- --- __�-- �. _ " � \� \\ ..._. � / �_� � ///J / II \ 11 v f� HOUR• ;►\--"�N it IJ • \\\I } �. � - \ \ S 1 I v\ 1 I I I , -v >,-�`. \ \l � ��.. \ \ I ` ---� ' � % /!v\ ,1�"rill f.,. It N. It w:-, l � , \ \ \ \\ - ,\ � • / �� \ --- IIII �\ __, �\`\— �\ 5� \\ \\\ \\ �� \\ N. TI IN Id/ • �`- �� iJ is jl\`\���\ vv�� \�-` .�f � / i� I \ �_-i r ( , ` i \�\'i // � \\ / l I l / j I `�� \. \x\ \\ J /N,\\ 1 / /�� :r, III \``, �/ 1 I l - `' � � ' _ •L.,, ;. ® -- Attachment 1 Laboratory Analytical Reports and Chain -of -Custody Forms leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 November 16, 2020 Jennifer Verde Anchor QEA 231 Haywood Street Asheville, NC 28801 RE: Project: Lassonde Pappas Pace Project No.: 92504561 Dear Jennifer Verde: Enclosed are the analytical results for sample(s) received by the laboratory on November 06, 2020. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, (Z/� ` - Lord Patton lorri.patton@pacelabs.com 1(828)254-7176 Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Project: Lassonde Pappas Pace Project No.: 92504561 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Project: Pace Project No.: Lassonde Pappas 92504561 Analytes Lab lD Sample ID Method Analysts Reported Laboratory 92504561001 MW-4 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561002 MW-5 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561003 MW-6 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561004 MW-7R SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561005 MW-8 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Project: Lassonde Pappas Pace Project No.: 92504561 Analytes Lab lD Sample ID Method Analysts Reported Laboratory EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561006 MW-9 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561007 SW-1 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A 92504561008 SW-2 SM 6200B SAS 63 PASI-C SM 2540C-2011 ALP 1 PASI-A SM 9222D-2006 ECH 1 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A EPA 353.2 Rev 2.0 1993 MFO 1 PASI-A EPA 365.1 Rev 2.0 1993 MDW 1 PASI-A SM 4500-CI-E-2011 CJL 1 PASI-A SM 531OB-2011 ECH 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 4 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-4 Lab ID: 92504561001 Collected: 11/06/20 13:21 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 00:42 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 00:42 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 00:42 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 00:42 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 00:42 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 00:42 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 00:42 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 00:42 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 00:42 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 00:42 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 00:42 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 00:42 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 00:42 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 00:42 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 00:42 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 00:42 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 00:42 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 00:42 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 00:42 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 00:42 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 00:42 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 00:42 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 00:42 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 00:42 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 00:42 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 00:42 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 00:42 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 00:42 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 00:42 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 00:42 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 00:42 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 00:42 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 00:42 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 00:42 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 00:42 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 00:42 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 00:42 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 00:42 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 00:42 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 00:42 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 00:42 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 00:42 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 00:42 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 00:42 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 00:42 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 00:42 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-4 Lab ID: 92504561001 Collected: 11/06/20 13:21 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 00:42 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 00:42 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 00:42 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 00:42 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 00:42 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 00:42 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 00:42 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 00:42 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 00:42 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 00:42 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 00:42 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 00:42 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 00:42 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 00:42 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 96 % 70-130 1 11/11/20 00:42 17060-07-0 4-Bromofluorobenzene (S) 96 % 70-130 1 11/11/20 00:42 460-00-4 Toluene-d8 (S) 101 % 70-130 1 11/11/20 00:42 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 148 mg/L 25.0 1 11/08/20 11:43 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms ND CFU/100 mL 1.0 1 11/06/20 17:08 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:35 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 0.73 mg/L 0.040 1 11/07/20 03:03 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus ND mg/L 0.050 1 11/09/20 19:00 11/10/20 21:12 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 6.9 mg/L 1.0 1 11/09/20 23:41 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 6 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-4 Lab ID: 92504561001 Collected: 11/06/20 13:21 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 2.8 mg/L 1.0 1 11/12/20 17:07 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 7 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-5 Lab ID: 92504561002 Collected: 11/06/20 13:15 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 01:00 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 01:00 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 01:00 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 01:00 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 01:00 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 01:00 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 01:00 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 01:00 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 01:00 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 01:00 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 01:00 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 01:00 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 01:00 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 01:00 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:00 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:00 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 01:00 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 01:00 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 01:00 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 01:00 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:00 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:00 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:00 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 01:00 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 01:00 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 01:00 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 01:00 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:00 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:00 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:00 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 01:00 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:00 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 01:00 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:00 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:00 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 01:00 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 01:00 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 01:00 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 01:00 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 01:00 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 01:00 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 01:00 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 01:00 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 01:00 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:00 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:00 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-5 Lab ID: 92504561002 Collected: 11/06/20 13:15 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene 0.80 ug/L 0.50 1 11/11/20 01:00 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 01:00 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:00 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:00 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 01:00 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 01:00 79-00-5 Trichloroethene 1.0 ug/L 0.50 1 11/11/20 01:00 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 01:00 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 01:00 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:00 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:00 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 01:00 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 01:00 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 01:00 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 98 % 70-130 1 11/11/20 01:00 17060-07-0 4-Bromofluorobenzene (S) 95 % 70-130 1 11/11/20 01:00 460-00-4 Toluene-d8 (S) 101 % 70-130 1 11/11/20 01:00 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 61.0 mg/L 25.0 1 11/08/20 11:43 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms 8.0 CFU/100 mL 1.0 1 11/06/20 17:08 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:40 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate ND mg/L 0.040 1 11/07/20 03:00 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus 0.060 mg/L 0.050 1 11/09/20 19:00 11/10/20 21:16 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 6.9 mg/L 1.0 1 11/09/20 23:42 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 9 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-5 Lab ID: 92504561002 Collected: 11/06/20 13:15 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 4.6 mg/L 1.0 1 11/12/20 17:31 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 10 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-6 Lab ID: 92504561003 Collected: 11/06/20 10:34 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 01:18 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 01:18 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 01:18 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 01:18 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 01:18 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 01:18 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 01:18 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 01:18 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 01:18 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 01:18 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 01:18 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 01:18 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 01:18 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 01:18 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:18 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:18 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 01:18 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 01:18 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 01:18 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 01:18 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:18 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:18 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:18 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 01:18 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 01:18 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 01:18 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 01:18 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:18 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:18 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:18 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 01:18 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:18 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 01:18 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:18 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:18 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 01:18 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 01:18 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 01:18 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 01:18 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 01:18 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 01:18 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 01:18 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 01:18 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 01:18 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:18 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:18 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-6 Lab ID: 92504561003 Collected: 11/06/20 10:34 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 01:18 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 01:18 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:18 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:18 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 01:18 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 01:18 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 01:18 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 01:18 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 01:18 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:18 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:18 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 01:18 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 01:18 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 01:18 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 99 % 70-130 1 11/11/20 01:18 17060-07-0 4-Bromofluorobenzene (S) 97 % 70-130 1 11/11/20 01:18 460-00-4 Toluene-d8 (S) 101 % 70-130 1 11/11/20 01:18 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 139 mg/L 25.0 1 11/08/20 11:43 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms 3.0 CFU/100 mL 1.0 1 11/06/20 15:47 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:47 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 3.2 mg/L 0.040 1 11/07/20 02:58 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus ND mg/L 0.050 1 11/09/20 19:00 11/10/20 21:18 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 12.5 mg/L 1.0 1 11/09/20 23:43 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 12 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-6 Lab ID: 92504561003 Collected: 11/06/20 10:34 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 2.6 mg/L 1.0 1 11/12/20 18:44 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 13 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-7R Lab ID: 92504561004 Collected: 11/06/20 08:49 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 01:35 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 01:35 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 01:35 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 01:35 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 01:35 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 01:35 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 01:35 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 01:35 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 01:35 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 01:35 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 01:35 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 01:35 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 01:35 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 01:35 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:35 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:35 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 01:35 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 01:35 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 01:35 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 01:35 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:35 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:35 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:35 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 01:35 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 01:35 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 01:35 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 01:35 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:35 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:35 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:35 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 01:35 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:35 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 01:35 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:35 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:35 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 01:35 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 01:35 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 01:35 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 01:35 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 01:35 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 01:35 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 01:35 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 01:35 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 01:35 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:35 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:35 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 14 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-7R Lab ID: 92504561004 Collected: 11/06/20 08:49 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 01:35 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 01:35 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:35 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:35 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 01:35 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 01:35 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 01:35 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 01:35 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 01:35 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:35 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:35 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 01:35 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 01:35 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 01:35 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 99 % 70-130 1 11/11/20 01:35 17060-07-0 4-Bromofluorobenzene (S) 98 % 70-130 1 11/11/20 01:35 460-00-4 Toluene-d8 (S) 102 % 70-130 1 11/11/20 01:35 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 205 mg/L 25.0 1 11/08/20 11:43 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms ND CFU/100 mL 1.0 1 11/06/20 15:47 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:52 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 13.0 mg/L 0.40 10 11/07/20 03:19 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus ND mg/L 0.050 1 11/09/20 19:00 11/10/20 21:18 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 17.8 mg/L 1.0 1 11/09/20 23:44 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 15 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-7R Lab ID: 92504561004 Collected: 11/06/20 08:49 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 1.7 mg/L 1.0 1 11/12/20 20:09 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 16 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-8 Lab ID: 92504561005 Collected: 11/06/20 09:27 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 01:53 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 01:53 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 01:53 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 01:53 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 01:53 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 01:53 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 01:53 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 01:53 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 01:53 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 01:53 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 01:53 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 01:53 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 01:53 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 01:53 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:53 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 01:53 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 01:53 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 01:53 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 01:53 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 01:53 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:53 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:53 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 01:53 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 01:53 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 01:53 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 01:53 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 01:53 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:53 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 01:53 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:53 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 01:53 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 01:53 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 01:53 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:53 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 01:53 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 01:53 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 01:53 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 01:53 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 01:53 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 01:53 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 01:53 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 01:53 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 01:53 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 01:53 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:53 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 01:53 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 17 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-8 Lab ID: 92504561005 Collected: 11/06/20 09:27 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 01:53 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 01:53 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:53 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 01:53 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 01:53 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 01:53 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 01:53 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 01:53 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 01:53 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:53 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 01:53 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 01:53 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 01:53 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 01:53 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 100 % 70-130 1 11/11/20 01:53 17060-07-0 4-Bromofluorobenzene (S) 96 % 70-130 1 11/11/20 01:53 460-00-4 Toluene-d8 (S) 100 % 70-130 1 11/11/20 01:53 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 127 mg/L 25.0 1 11/08/20 11:44 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms 14.0 CFU/100 mL 1.0 1 11/06/20 15:47 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:53 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 2.4 mg/L 0.040 1 11/07/20 02:55 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus ND mg/L 0.050 1 11/09/20 19:00 11/10/20 21:19 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 2.3 mg/L 1.0 1 11/09/20 23:45 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 18 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-8 Lab ID: 92504561005 Collected: 11/06/20 09:27 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 2.8 mg/L 1.0 1 11/12/20 20:33 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 19 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-9 Lab ID: 92504561006 Collected: 11/06/20 12:16 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 02:11 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 02:11 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 02:11 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 02:11 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 02:11 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 02:11 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 02:11 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 02:11 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 02:11 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 02:11 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 02:11 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 02:11 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 02:11 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 02:11 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 02:11 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 02:11 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 02:11 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 02:11 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 02:11 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 02:11 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:11 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:11 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:11 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 02:11 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 02:11 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 02:11 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 02:11 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 02:11 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 02:11 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 02:11 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 02:11 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 02:11 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 02:11 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 02:11 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 02:11 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 02:11 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 02:11 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 02:11 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 02:11 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 02:11 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 02:11 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 02:11 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 02:11 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 02:11 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 02:11 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 02:11 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 20 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-9 Lab ID: 92504561006 Collected: 11/06/20 12:16 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 02:11 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 02:11 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 02:11 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 02:11 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 02:11 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 02:11 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 02:11 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 02:11 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 02:11 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 02:11 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 02:11 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 02:11 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 02:11 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 02:11 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 99 % 70-130 1 11/11/20 02:11 17060-07-0 4-Bromofluorobenzene (S) 96 % 70-130 1 11/11/20 02:11 460-00-4 Toluene-d8 (S) 101 % 70-130 1 11/11/20 02:11 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 88.0 mg/L 25.0 1 11/08/20 11:44 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms 16.0 CFU/100 mL 1.0 1 11/06/20 17:08 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:54 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 0.043 mg/L 0.040 1 11/07/20 02:59 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus 0.095 mg/L 0.050 1 11/09/20 19:00 11/10/20 21:20 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 1.4 mg/L 1.0 1 11/09/20 23:47 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 21 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: MW-9 Lab ID: 92504561006 Collected: 11/06/20 12:16 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 4.5 mg/L 1.0 1 11/12/20 20:58 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 22 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: SW-1 Lab ID: 92504561007 Collected: 11/06/20 14:00 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 02:29 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 02:29 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 02:29 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 02:29 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 02:29 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 02:29 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 02:29 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 02:29 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 02:29 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 02:29 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 02:29 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 02:29 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 02:29 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 02:29 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 02:29 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 02:29 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 02:29 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 02:29 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 02:29 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 02:29 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:29 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:29 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:29 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 02:29 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 02:29 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 02:29 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 02:29 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 02:29 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 02:29 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 02:29 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 02:29 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 02:29 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 02:29 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 02:29 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 02:29 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 02:29 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 02:29 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 02:29 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 02:29 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 02:29 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 02:29 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 02:29 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 02:29 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 02:29 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 02:29 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 02:29 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 23 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: SW-1 Lab ID: 92504561007 Collected: 11/06/20 14:00 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 02:29 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 02:29 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 02:29 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 02:29 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 02:29 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 02:29 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 02:29 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 02:29 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 02:29 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 02:29 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 02:29 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 02:29 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 02:29 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 02:29 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 97 % 70-130 1 11/11/20 02:29 17060-07-0 4-Bromofluorobenzene (S) 97 % 70-130 1 11/11/20 02:29 460-00-4 Toluene-d8 (S) 100 % 70-130 1 11/11/20 02:29 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 56.0 mg/L 25.0 1 11/08/20 11:44 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms 145 CFU/100 mL 1.0 1 11/06/20 17:08 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:56 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 0.71 mg/L 0.040 1 11/07/20 03:07 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus ND mg/L 0.050 1 11/09/20 19:00 11/10/20 21:20 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 4.4 mg/L 1.0 1 11/09/20 23:48 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 24 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: SW-1 Lab ID: 92504561007 Collected: 11/06/20 14:00 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 1.6 mg/L 1.0 1 11/12/20 21:28 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 25 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: SW-2 Lab ID: 92504561008 Collected: 11/06/20 09:52 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Benzene ND ug/L 0.50 1 11/11/20 02:47 71-43-2 Bromobenzene ND ug/L 0.50 1 11/11/20 02:47 108-86-1 Bromochloromethane ND ug/L 0.50 1 11/11/20 02:47 74-97-5 Bromodichloromethane ND ug/L 0.50 1 11/11/20 02:47 75-27-4 Bromoform ND ug/L 0.50 1 11/11/20 02:47 75-25-2 Bromomethane ND ug/L 5.0 1 11/11/20 02:47 74-83-9 n-Butylbenzene ND ug/L 0.50 1 11/11/20 02:47 104-51-8 sec-Butylbenzene ND ug/L 0.50 1 11/11/20 02:47 135-98-8 tert-Butyl benzene ND ug/L 0.50 1 11/11/20 02:47 98-06-6 Carbon tetrachloride ND ug/L 0.50 1 11/11/20 02:47 56-23-5 Chlorobenzene ND ug/L 0.50 1 11/11/20 02:47 108-90-7 Chloroethane ND ug/L 1.0 1 11/11/20 02:47 75-00-3 Chloroform ND ug/L 0.50 1 11/11/20 02:47 67-66-3 Chloromethane ND ug/L 1.0 1 11/11/20 02:47 74-87-3 2-Chlorotoluene ND ug/L 0.50 1 11/11/20 02:47 95-49-8 4-Chlorotoluene ND ug/L 0.50 1 11/11/20 02:47 106-43-4 1,2-Dibromo-3-chloropropane ND ug/L 1.0 1 11/11/20 02:47 96-12-8 Dibromochloromethane ND ug/L 0.50 1 11/11/20 02:47 124-48-1 1,2-Dibromoethane (EDB) ND ug/L 0.50 1 11/11/20 02:47 106-93-4 Dibromomethane ND ug/L 0.50 1 11/11/20 02:47 74-95-3 1,2-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:47 95-50-1 1,3-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:47 541-73-1 1,4-Dichlorobenzene ND ug/L 0.50 1 11/11/20 02:47 106-46-7 Dichlorodifluoromethane ND ug/L 0.50 1 11/11/20 02:47 75-71-8 1,1-Dichloroethane ND ug/L 0.50 1 11/11/20 02:47 75-34-3 1,2-Dichloroethane ND ug/L 0.50 1 11/11/20 02:47 107-06-2 1,1-Dichloroethene ND ug/L 0.50 1 11/11/20 02:47 75-35-4 cis-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 02:47 156-59-2 trans-1,2-Dichloroethene ND ug/L 0.50 1 11/11/20 02:47 156-60-5 1,2-Dichloropropane ND ug/L 0.50 1 11/11/20 02:47 78-87-5 1,3-Dichloropropane ND ug/L 0.50 1 11/11/20 02:47 142-28-9 2,2-Dichloropropane ND ug/L 0.50 1 11/11/20 02:47 594-20-7 1,1-Dichloropropene ND ug/L 0.50 1 11/11/20 02:47 563-58-6 cis-1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 02:47 10061-01-5 trans- 1,3-Dichloropropene ND ug/L 0.50 1 11/11/20 02:47 10061-02-6 Diisopropyl ether ND ug/L 0.50 1 11/11/20 02:47 108-20-3 Ethylbenzene ND ug/L 0.50 1 11/11/20 02:47 100-41-4 Hexachloro-1,3-butadiene ND ug/L 2.0 1 11/11/20 02:47 87-68-3 Isopropylbenzene (Cumene) ND ug/L 0.50 1 11/11/20 02:47 98-82-8 Methylene Chloride ND ug/L 2.0 1 11/11/20 02:47 75-09-2 Methyl-tert-butyl ether ND ug/L 0.50 1 11/11/20 02:47 1634-04-4 Naphthalene ND ug/L 2.0 1 11/11/20 02:47 91-20-3 n-Propylbenzene ND ug/L 0.50 1 11/11/20 02:47 103-65-1 Styrene ND ug/L 0.50 1 11/11/20 02:47 100-42-5 1,1,1,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 02:47 630-20-6 1,1,2,2-Tetrachloroethane ND ug/L 0.50 1 11/11/20 02:47 79-34-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 26 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: SW-2 Lab ID: 92504561008 Collected: 11/06/20 09:52 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6200B MSV Analytical Method: SM 6200B Pace Analytical Services - Charlotte Tetrachloroethene ND ug/L 0.50 1 11/11/20 02:47 127-18-4 Toluene ND ug/L 0.50 1 11/11/20 02:47 108-88-3 1,2,3-Trichlorobenzene ND ug/L 2.0 1 11/11/20 02:47 87-61-6 1,2,4-Trichlorobenzene ND ug/L 2.0 1 11/11/20 02:47 120-82-1 1,1,1-Trichloroethane ND ug/L 0.50 1 11/11/20 02:47 71-55-6 1,1,2-Trichloroethane ND ug/L 0.50 1 11/11/20 02:47 79-00-5 Trichloroethene ND ug/L 0.50 1 11/11/20 02:47 79-01-6 Trichlorofluoromethane ND ug/L 1.0 1 11/11/20 02:47 75-69-4 1,2,3-Trichloropropane ND ug/L 0.50 1 11/11/20 02:47 96-18-4 1,2,4-Trimethylbenzene ND ug/L 0.50 1 11/11/20 02:47 95-63-6 1,3,5-Trimethylbenzene ND ug/L 0.50 1 11/11/20 02:47 108-67-8 Vinyl chloride ND ug/L 1.0 1 11/11/20 02:47 75-01-4 m&p-Xylene ND ug/L 1.0 1 11/11/20 02:47 179601-23-1 o-Xylene ND ug/L 0.50 1 11/11/20 02:47 95-47-6 Surrogates 1,2-Dichloroethane-d4 (S) 101 % 70-130 1 11/11/20 02:47 17060-07-0 4-Bromofluorobenzene (S) 97 % 70-130 1 11/11/20 02:47 460-00-4 Toluene-d8 (S) 101 % 70-130 1 11/11/20 02:47 2037-26-5 2540C Total Dissolved Solids Analytical Method: SM 2540C-2011 Pace Analytical Services -Asheville Total Dissolved Solids 59.0 mg/L 25.0 1 11/08/20 11:44 MBIO 9222D Fecal Coliform AVL Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services -Asheville Fecal Coliforms 97.0 CFU/100 mL 1.0 1 11/06/20 15:47 11/07/20 15:33 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Ammonia ND mg/L 0.10 1 11/10/20 12:57 7664-41-7 353.2 Nitrogen, NO2/1403 unpres Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services -Asheville Nitrogen, Nitrate 0.70 mg/L 0.040 1 11/07/20 02:56 14797-55-8 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services -Asheville Phosphorus ND mg/L 0.050 1 11/09/20 19:00 11/10/20 21:21 7723-14-0 4500 Chloride Analytical Method: SM 4500-CI-E-2011 Pace Analytical Services -Asheville Chloride 4.4 mg/L 1.0 1 11/09/20 23:50 16887-00-6 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 27 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: Lassonde Pappas Pace Project No.: 92504561 Sample: SW-2 Lab ID: 92504561008 Collected: 11/06/20 09:52 Received: 11/06/20 14:55 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 5310B TOC Analytical Method: SM 531OB-2011 Pace Analytical Services -Asheville Total Organic Carbon 1.6 mg/L 1.0 1 11/12/20 22:04 7440-44-0 Date: 11/16/2020 01:39 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 28 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 579267 Analysis Method: SM 6200B QC Batch Method: SM 6200B Analysis Description: 6200E MSV Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3064425 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers 1,1,1,2-Tetrachloroethane ug/L ND 0.50 11/11/20 00:06 1,1,1-Trichloroethane ug/L ND 0.50 11/11/20 00:06 1,1,2,2-Tetrachloroethane ug/L ND 0.50 11/11/20 00:06 1,1,2-Trichloroethane ug/L ND 0.50 11/11/20 00:06 1,1-Dichloroethane ug/L ND 0.50 11/11/20 00:06 1,1-Dichloroethene ug/L ND 0.50 11/11/20 00:06 1,1-Dichloropropene ug/L ND 0.50 11/11/20 00:06 1,2,3-Trichlorobenzene ug/L ND 2.0 11/11/20 00:06 1,2,3-Trichloropropane ug/L ND 0.50 11/11/20 00:06 1,2,4-Trichlorobenzene ug/L ND 2.0 11/11/20 00:06 1,2,4-Trimethylbenzene ug/L ND 0.50 11/11/20 00:06 1,2-Dibromo-3-chloropropane ug/L ND 1.0 11/11/20 00:06 1,2-Dibromoethane (EDB) ug/L ND 0.50 11/11/20 00:06 1,2-Dichlorobenzene ug/L ND 0.50 11/11/20 00:06 1,2-Dichloroethane ug/L ND 0.50 11/11/20 00:06 1,2-Dichloropropane ug/L ND 0.50 11/11/20 00:06 1,3,5-Trimethylbenzene ug/L ND 0.50 11/11/20 00:06 1,3-Dichlorobenzene ug/L ND 0.50 11/11/20 00:06 1,3-Dichloropropane ug/L ND 0.50 11/11/20 00:06 1,4-Dichlorobenzene ug/L ND 0.50 11/11/20 00:06 2,2-Dichloropropane ug/L ND 0.50 11/11/20 00:06 2-Chlorotoluene ug/L ND 0.50 11/11/20 00:06 4-Chlorotoluene ug/L ND 0.50 11/11/20 00:06 Benzene ug/L ND 0.50 11/11/20 00:06 Bromobenzene ug/L ND 0.50 11/11/20 00:06 Bromochloromethane ug/L ND 0.50 11/11/20 00:06 Bromodichloromethane ug/L ND 0.50 11/11/20 00:06 Bromoform ug/L ND 0.50 11/11/20 00:06 Bromomethane ug/L ND 5.0 11/11/20 00:06 Carbon tetrachloride ug/L ND 0.50 11/11/20 00:06 Chlorobenzene ug/L ND 0.50 11/11/20 00:06 Chloroethane ug/L ND 1.0 11/11/20 00:06 Chloroform ug/L ND 0.50 11/11/20 00:06 Chloromethane ug/L ND 1.0 11/11/20 00:06 cis-1,2-Dichloroethene ug/L ND 0.50 11/11/20 00:06 cis-1,3-Dichloropropene ug/L ND 0.50 11/11/20 00:06 Dibromochloromethane ug/L ND 0.50 11/11/20 00:06 Dibromomethane ug/L ND 0.50 11/11/20 00:06 Dichlorodifluoromethane ug/L ND 0.50 11/11/20 00:06 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 29 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 METHOD BLANK: 3064425 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Diisopropyl ether ug/L ND 0.50 11/11/20 00:06 Ethylbenzene ug/L ND 0.50 11/11/20 00:06 Hexachloro-1,3-butadiene ug/L ND 2.0 11/11/20 00:06 Isopropylbenzene (Cumene) ug/L ND 0.50 11/11/20 00:06 m&p-Xylene ug/L ND 1.0 11/11/20 00:06 Methyl-tert-butyl ether ug/L ND 0.50 11/11/20 00:06 Methylene Chloride ug/L ND 2.0 11/11/20 00:06 n-Butylbenzene ug/L ND 0.50 11/11/20 00:06 n-Propylbenzene ug/L ND 0.50 11/11/20 00:06 Naphthalene ug/L ND 2.0 11/11/20 00:06 o-Xylene ug/L ND 0.50 11/11/20 00:06 sec-Butylbenzene ug/L ND 0.50 11/11/20 00:06 Styrene ug/L ND 0.50 11/11/20 00:06 tert-Butyl benzene ug/L ND 0.50 11/11/20 00:06 Tetrachloroethene ug/L ND 0.50 11/11/20 00:06 Toluene ug/L ND 0.50 11/11/20 00:06 trans-1,2-Dichloroethene ug/L ND 0.50 11/11/20 00:06 trans- 1,3-Dichloropropene ug/L ND 0.50 11/11/20 00:06 Trichloroethene ug/L ND 0.50 11/11/20 00:06 Trichlorofluoromethane ug/L ND 1.0 11/11/20 00:06 Vinyl chloride ug/L ND 1.0 11/11/20 00:06 1,2-Dichloroethane-d4 (S) % 96 70-130 11/11/20 00:06 4-Bromofluorobenzene (S) % 96 70-130 11/11/20 00:06 Toluene-d8 (S) % 100 70-130 11/11/20 00:06 LABORATORY CONTROL SAMPLE: Parameter 3064426 Units Spike Conc. LCS Result LCS % Rec % Rec Limits Qualifiers 1,1,1,2-Tetrachloroethane ug/L 50 52.7 105 60-140 1,1,1-Trichloroethane ug/L 50 49.5 99 60-140 1,1,2,2-Tetrachloroethane ug/L 50 50.9 102 60-140 1,1,2-Trichloroethane ug/L 50 50.0 100 60-140 1,1-Dichloroethane ug/L 50 49.2 98 60-140 1,1-Dichloroethene ug/L 50 50.7 101 60-140 1,1-Dichloropropene ug/L 50 48.9 98 60-140 1,2,3-Trichlorobenzene ug/L 50 52.9 106 60-140 1,2,3-Trichloropropane ug/L 50 49.2 98 60-140 1,2,4-Trichlorobenzene ug/L 50 55.4 111 60-140 1,2,4-Trimethylbenzene ug/L 50 52.1 104 60-140 1,2-Dibromo-3-chloropropane ug/L 50 54.7 109 60-140 1,2-Dibromoethane (EDB) ug/L 50 51.4 103 60-140 1,2-Dichlorobenzene ug/L 50 53.9 108 60-140 1,2-Dichloroethane ug/L 50 44.7 89 60-140 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 30 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 LABORATORY CONTROL SAMPLE: Parameter 3064426 Units Spike Conc. LCS Result LCS % Rec % Rec Limits 1,2-Dichloropropane ug/L 50 50.3 101 60-140 1,3,5-Trimethylbenzene ug/L 50 51.8 104 60-140 1,3-Dichlorobenzene ug/L 50 53.7 107 60-140 1,3-Dichloropropane ug/L 50 52.0 104 60-140 1,4-Dichlorobenzene ug/L 50 53.7 107 60-140 2,2-Dichloropropane ug/L 50 47.8 96 60-140 2-Chlorotoluene ug/L 50 52.8 106 60-140 4-Chlorotoluene ug/L 50 50.7 101 60-140 Benzene ug/L 50 50.1 100 60-140 Bromobenzene ug/L 50 50.2 100 60-140 Bromochloromethane ug/L 50 49.1 98 60-140 Bromodichloromethane ug/L 50 49.6 99 60-140 Bromoform ug/L 50 50.6 101 60-140 Bromomethane ug/L 50 56.1 112 60-140 Carbon tetrachloride ug/L 50 46.8 94 60-140 Chlorobenzene ug/L 50 51.1 102 60-140 Chloroethane ug/L 50 39.1 78 60-140 Chloroform ug/L 50 51.3 103 60-140 Chloromethane ug/L 50 41.6 83 60-140 cis-1,2-Dichloroethene ug/L 50 48.5 97 60-140 cis-1,3-Dichloropropene ug/L 50 52.1 104 60-140 Dibromochloromethane ug/L 50 54.2 108 60-140 Dibromomethane ug/L 50 52.4 105 60-140 Dichlorodifluoromethane ug/L 50 37.3 75 60-140 Diisopropyl ether ug/L 50 47.7 95 60-140 Ethylbenzene ug/L 50 50.0 100 60-140 Hexachloro-1,3-butadiene ug/L 50 49.4 99 60-140 Isopropylbenzene (Cumene) ug/L 50 53.1 106 60-140 m&p-Xylene ug/L 100 102 102 60-140 Methyl-tert-butyl ether ug/L 50 49.4 99 60-140 Methylene Chloride ug/L 50 46.6 93 60-140 n-Butylbenzene ug/L 50 53.1 106 60-140 n-Propylbenzene ug/L 50 51.2 102 60-140 Naphthalene ug/L 50 55.8 112 60-140 o-Xylene ug/L 50 51.0 102 60-140 sec-Butylbenzene ug/L 50 50.7 101 60-140 Styrene ug/L 50 52.7 105 60-140 tert-Butyl benzene ug/L 50 44.3 89 60-140 Tetrachloroethene ug/L 50 50.4 101 60-140 Toluene ug/L 50 49.2 98 60-140 trans-1,2-Dichloroethene ug/L 50 48.8 98 60-140 trans- 1,3-Dichloropropene ug/L 50 51.0 102 60-140 Trichloroethene ug/L 50 50.6 101 60-140 Trichlorofluoromethane ug/L 50 39.3 79 60-140 Vinyl chloride ug/L 50 42.4 85 60-140 1,2-Dichloroethane-d4 (S) % 95 70-130 4-Bromofluorobenzene (S) % 101 70-130 Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 31 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 LABORATORY CONTROL SAMPLE: 3064426 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Toluene-d8 (S) % 98 70-130 Qualifiers MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3064427 MS 92504571003 Spike Parameter Units Result Conc. MSD Spike Conc. 3064428 MS Result MSD Result MS % Rec MSD % Rec % Rec Limits RPD Qual 1,1,1,2-Tetrachloroethane ug/L ND 4000 4000 4320 4180 108 104 60-140 3 1,1,1-Trichloroethane ug/L ND 4000 4000 4300 4290 108 107 60-140 0 1,1,2,2-Tetrachloroethane ug/L ND 4000 4000 3920 3900 98 97 60-140 0 1,1,2-Trichloroethane ug/L ND 4000 4000 4170 4070 104 102 60-140 2 1,1-Dichloroethane ug/L ND 4000 4000 4080 4150 102 104 60-140 2 1,1-Dichloroethene ug/L ND 4000 4000 4590 4630 115 116 60-140 1 1,1-Dichloropropene ug/L ND 4000 4000 4290 4300 107 108 60-140 0 1,2,3-Trichlorobenzene ug/L ND 4000 4000 4060 4170 102 104 60-140 3 1,2,3-Trichloropropane ug/L ND 4000 4000 3890 3920 97 98 60-140 1 1,2,4-Trichlorobenzene ug/L ND 4000 4000 4270 4270 107 107 60-140 0 1,2,4-Trimethylbenzene ug/L 1180 4000 4000 5580 5540 110 109 60-140 1 1,2-Dibromo-3-chloropropane ug/L ND 4000 4000 3960 3960 99 99 60-140 0 1,2-Dibromoethane (EDB) ug/L 358 4000 4000 4550 4510 105 104 60-140 1 1,2-Dichlorobenzene ug/L ND 4000 4000 4310 4290 108 107 60-140 0 1,2-Dichloroethane ug/L 177 4000 4000 3810 3850 91 92 60-140 1 1,2-Dichloropropane ug/L ND 4000 4000 4270 4300 107 107 60-140 1 1,3,5-Trimethylbenzene ug/L ND 4000 4000 4750 4740 119 118 60-140 0 1,3-Dichlorobenzene ug/L ND 4000 4000 4380 4380 109 109 60-140 0 1,3-Dichloropropane ug/L ND 4000 4000 4170 4180 104 104 60-140 0 1,4-Dichlorobenzene ug/L ND 4000 4000 4350 4340 109 109 60-140 0 2,2-Dichloropropane ug/L ND 4000 4000 3440 3470 86 87 60-140 1 2-Chlorotoluene ug/L ND 4000 4000 4420 4370 111 109 60-140 1 4-Chlorotoluene ug/L ND 4000 4000 4280 4320 107 108 60-140 1 Benzene ug/L 4730 4000 4000 8930 9240 105 113 60-140 3 Bromobenzene ug/L ND 4000 4000 4230 4160 106 104 60-140 2 Bromochloromethane ug/L ND 4000 4000 4060 4020 102 101 60-140 1 Bromodichloromethane ug/L ND 4000 4000 4070 4040 102 101 60-140 1 Bromoform ug/L ND 4000 4000 3710 3740 93 93 60-140 1 Bromomethane ug/L ND 4000 4000 4930 5050 123 126 60-140 2 Carbon tetrachloride ug/L ND 4000 4000 4170 4300 104 107 60-140 3 Chlorobenzene ug/L ND 4000 4000 4260 4230 107 106 60-140 1 Chloroethane ug/L ND 4000 4000 3860 4020 97 101 60-140 4 Chloroform ug/L ND 4000 4000 4300 4040 107 101 60-140 6 Chloromethane ug/L ND 4000 4000 3510 3680 88 92 60-140 5 cis-1,2-Dichloroethene ug/L ND 4000 4000 4160 4120 104 103 60-140 1 cis-1,3-Dichloropropene ug/L ND 4000 4000 4040 4090 101 102 60-140 1 Dibromochloromethane ug/L ND 4000 4000 4240 4110 106 103 60-140 3 Dibromomethane ug/L ND 4000 4000 4190 4250 105 106 60-140 1 Dichlorodifluoromethane ug/L ND 4000 4000 3740 3720 94 93 60-140 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 32 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3064427 MS 92504571003 Spike Parameter Units Result Conc. MSD Spike Conc. 3064428 MS Result MSD Result MS % Rec MSD % Rec % Rec Limits RPD Qual Diisopropyl ether ug/L ND 4000 4000 3870 3950 96 98 60-140 2 Ethylbenzene ug/L 1140 4000 4000 5420 5410 107 107 60-140 0 Hexachloro-1,3-butadiene ug/L ND 4000 4000 4100 4020 102 101 60-140 2 Isopropylbenzene (Cumene) ug/L ND 4000 4000 4550 4560 114 114 60-140 0 m&p-Xylene ug/L 5010 8000 8000 13600 13900 107 111 60-140 2 Methyl-tert-butyl ether ug/L ND 4000 4000 3980 3910 100 98 60-140 2 Methylene Chloride ug/L ND 4000 4000 3760 3850 94 96 60-140 2 n-Butylbenzene ug/L ND 4000 4000 4300 4380 108 110 60-140 2 n-Propylbenzene ug/L ND 4000 4000 4630 4590 116 115 60-140 1 Naphthalene ug/L ND 4000 4000 4340 4420 104 105 60-140 2 o-Xylene ug/L 3010 4000 4000 7380 7480 109 112 60-140 1 sec-Butylbenzene ug/L ND 4000 4000 4380 4390 110 110 60-140 0 Styrene ug/L ND 4000 4000 4320 4290 108 107 60-140 1 tert-Butyl benzene ug/L ND 4000 4000 3840 3840 96 96 60-140 0 Tetrachloroethene ug/L ND 4000 4000 4310 4320 108 108 60-140 0 Toluene ug/L 21100 4000 4000 25000 26300 98 131 60-140 5 trans-1,2-Dichloroethene ug/L ND 4000 4000 4210 4300 105 107 60-140 2 trans- 1,3-Dichloropropene ug/L ND 4000 4000 3950 3960 99 99 60-140 0 Trichloroethene ug/L ND 4000 4000 4340 4270 109 107 60-140 2 Trichlorofluoromethane ug/L ND 4000 4000 3980 4030 100 101 60-140 1 Vinyl chloride ug/L ND 4000 4000 3780 3840 94 96 60-140 2 1,2-Dichloroethane-d4 (S) % 98 101 70-130 4-Bromofluorobenzene (S) % 99 98 70-130 Toluene-d8(S) % 98 99 70-130 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 33 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 578777 Analysis Method: SM 2540C-2011 QC Batch Method: SM 2540C-2011 Analysis Description: 2540C Total Dissolved Solids Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3062340 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Dissolved Solids mg/L ND 25.0 11/08/20 11:41 LABORATORY CONTROL SAMPLE: 3062341 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Dissolved Solids mg/L 250 248 99 90-110 SAMPLE DUPLICATE: 3062342 92504334001 Dup Parameter Units Result Result RPD Qualifiers Total Dissolved Solids mg/L 106000 ug/L 116 9 SAMPLE DUPLICATE: 3062343 92504561002 Dup Parameter Units Result Result RPD Qualifiers Total Dissolved Solids mg/L 61.0 60.0 2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 34 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 578682 Analysis Method: SM 9222D-2006 QC Batch Method: SM 9222D-2006 Analysis Description: 9222D Fecal Coliform(MF) -AVL Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3061988 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Fecal Coliforms CFU/100 mL ND 1.0 11/07/20 15:33 SAMPLE DUPLICATE: 3061989 92504561004 Dup Parameter Units Result Result RPD Qualifiers Fecal Coliforms CFU/100 mL ND ND Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 35 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 579004 Analysis Method: EPA 350.1 Rev 2.0 1993 QC Batch Method: EPA 350.1 Rev 2.0 1993 Analysis Description: 350.1 Ammonia Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001 METHOD BLANK: 3063400 Associated Lab Samples: 92504561001 Parameter Units Nitrogen, Ammonia mg/L LABORATORY CONTROL SAMPLE: 3063401 Parameter Units Nitrogen, Ammonia mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.10 11/10/2011:53 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 5 4.8 97 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063402 3063403 MS MSD 92503866004 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Ammonia mg/L 1.1 5 5 5.8 5.8 94 94 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063404 3063405 MS MSD 92503881001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Ammonia mg/L 29.8 5 5 34.7 34.0 97 84 90-110 2 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 36 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 579005 Analysis Method: EPA 350.1 Rev 2.0 1993 QC Batch Method: EPA 350.1 Rev 2.0 1993 Analysis Description: 350.1 Ammonia Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3063406 Matrix: Water Associated Lab Samples: 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Nitrogen, Ammonia mg/L ND 0.10 11/10/20 12:37 LABORATORY CONTROL SAMPLE: 3063407 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Nitrogen, Ammonia mg/L 5 4.8 96 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063408 3063409 MS MSD 92504561002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Ammonia mg/L ND 5 5 4.8 4.8 95 95 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063410 3063411 MS MSD 92504561003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Ammonia mg/L ND 5 5 4.7 4.7 94 94 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 37 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 578705 Analysis Method: EPA 353.2 Rev 2.0 1993 QC Batch Method: EPA 353.2 Rev 2.0 1993 Analysis Description: 353.2 Nitrate + Nitrite, Unpres. Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3062116 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Nitrogen, Nitrate mg/L ND 0.040 11/07/20 02:43 LABORATORY CONTROL SAMPLE: 3062117 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Nitrogen, Nitrate mg/L 1.5 1.5 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3062118 3062119 MS MSD 92504561004 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Nitrate mg/L 13.0 1.5 1.5 15.1 14.2 142 84 90-110 6 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3062120 3062121 MS MSD 92504561001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Nitrate mg/L 0.73 1.5 1.5 2.2 2.2 98 97 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 38 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 578977 Analysis Method: EPA 365.1 Rev 2.0 1993 QC Batch Method: EPA 365.1 Rev 2.0 1993 Analysis Description: 365.1 Phosphorus, Total Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3063304 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Phosphorus mg/L ND 0.050 11/10/20 21:11 LABORATORY CONTROL SAMPLE: 3063305 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Phosphorus mg/L 2.5 2.5 99 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063306 3063307 MS MSD 92504561001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L ND 2.5 2.5 2.5 2.5 98 99 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063308 3063309 MS MSD 92504561002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 0.060 2.5 2.5 2.6 2.6 100 101 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 39 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 579054 Analysis Method: SM 4500-CI-E-2011 QC Batch Method: SM 4500-CI-E-2011 Analysis Description: 4500 Chloride Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005 METHOD BLANK: 3063590 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Chloride mg/L ND 1.0 11/09/2023:19 LABORATORY CONTROL SAMPLE: 3063591 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Chloride mg/L 20 20.6 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063627 3063628 MS MSD 92503890002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Chloride mg/L 54.6 10 10 65.6 63.7 110 91 90-110 3 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063629 3063630 MS MSD 92503896001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Chloride mg/L 6.7 10 10 16.7 16.6 100 99 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 40 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 579055 Analysis Method: SM 4500-CI-E-2011 QC Batch Method: SM 4500-CI-E-2011 Analysis Description: 4500 Chloride Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561006, 92504561007, 92504561008 METHOD BLANK: 3063596 Matrix: Water Associated Lab Samples: 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Chloride mg/L ND 1.0 11/09/2023:45 LABORATORY CONTROL SAMPLE: 3063597 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Chloride mg/L 20 20.6 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063631 3063632 MS MSD 92504093001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Chloride mg/L 9.6 10 10 19.1 19.0 94 94 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3063633 3063634 MS MSD 92504093006 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Chloride mg/L 1.7 10 10 12.1 11.9 103 102 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 41 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Lassonde Pappas Pace Project No.: 92504561 QC Batch: 579489 Analysis Method: SM 531 OB-2011 QC Batch Method: SM 531 OB-2011 Analysis Description: 5310E TOC Laboratory: Pace Analytical Services -Asheville Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 METHOD BLANK: 3065625 Matrix: Water Associated Lab Samples: 92504561001, 92504561002, 92504561003, 92504561004, 92504561005, 92504561006, 92504561007, 92504561008 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Organic Carbon mg/L ND 1.0 11/11/20 23:33 LABORATORY CONTROL SAMPLE: 3065626 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Organic Carbon mg/L 25 24.4 98 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3065627 3065628 MS MSD 92502998001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Total Organic Carbon mg/L ND 25 25 25.7 25.8 99 99 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3065629 3065630 MS MSD 92504561002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Total Organic Carbon mg/L 4.6 25 25 29.2 29.3 99 99 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 42 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALIFIERS Project: Lassonde Pappas Pace Project No.: 92504561 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI -The NELAC Institute. ANALYTE QUALIFIERS M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 43 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Lassonde Pappas Pace Project No.: 92504561 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92504561001 MW-4 SM 6200B 579267 92504561002 MW-5 SM 6200B 579267 92504561003 MW-6 SM 6200B 579267 92504561004 MW-7R SM 6200B 579267 92504561005 MW-8 SM 6200B 579267 92504561006 MW-9 SM 6200B 579267 92504561007 SW-1 SM 6200E 579267 92504561008 SW-2 SM 6200E 579267 92504561001 MW-4 SM 2540C-2011 578777 92504561002 MW-5 SM 2540C-2011 578777 92504561003 MW-6 SM 2540C-2011 578777 92504561004 MW-7R SM 2540C-2011 578777 92504561005 MW-8 SM 2540C-2011 578777 92504561006 MW-9 SM 2540C-2011 578777 92504561007 SW-1 SM 2540C-2011 578777 92504561008 SW-2 SM 2540C-2011 578777 92504561001 MW-4 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561002 MW-5 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561003 MW-6 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561004 MW-7R SM 9222D-2006 578682 SM 9222D-2006 578683 92504561005 MW-8 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561006 MW-9 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561007 SW-1 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561008 SW-2 SM 9222D-2006 578682 SM 9222D-2006 578683 92504561001 MW-4 EPA 350.1 Rev 2.0 1993 579004 92504561002 MW-5 EPA 350.1 Rev 2.0 1993 579005 92504561003 MW-6 EPA 350.1 Rev 2.0 1993 579005 92504561004 MW-7R EPA 350.1 Rev 2.0 1993 579005 92504561005 MW-8 EPA 350.1 Rev 2.0 1993 579005 92504561006 MW-9 EPA 350.1 Rev 2.0 1993 579005 92504561007 SW-1 EPA 350.1 Rev 2.0 1993 579005 92504561008 SW-2 EPA 350.1 Rev 2.0 1993 579005 92504561001 MW-4 EPA 353.2 Rev 2.0 1993 578705 92504561002 MW-5 EPA 353.2 Rev 2.0 1993 578705 92504561003 MW-6 EPA 353.2 Rev 2.0 1993 578705 92504561004 MW-7R EPA 353.2 Rev 2.0 1993 578705 92504561005 MW-8 EPA 353.2 Rev 2.0 1993 578705 92504561006 MW-9 EPA 353.2 Rev 2.0 1993 578705 92504561007 SW-1 EPA 353.2 Rev 2.0 1993 578705 92504561008 SW-2 EPA 353.2 Rev 2.0 1993 578705 92504561001 MW-4 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561002 MW-5 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561003 MW-6 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561004 MW-7R EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561005 MW-8 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561006 MW-9 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 44 of 48 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Lassonde Pappas Pace Project No.: 92504561 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92504561007 SW-1 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561008 SW-2 EPA 365.1 Rev 2.0 1993 578977 EPA 365.1 Rev 2.0 1993 579311 92504561001 MW-4 SM 4500-CI-E-2011 579054 92504561002 MW-5 SM 4500-CI-E-2011 579054 92504561003 MW-6 SM 4500-CI-E-2011 579054 92504561004 MW-7R SM 4500-CI-E-2011 579054 92504561005 MW-8 SM 4500-CI-E-2011 579054 92504561006 MW-9 SM 4500-CI-E-2011 579055 92504561007 SW-1 SM 4500-CI-E-2011 579055 92504561008 SW-2 SM 4500-CI-E-2011 579055 92504561001 MW-4 SM 5310B-2011 579489 92504561002 MW-5 SM 5310B-2011 579489 92504561003 MW-6 SM 5310B-2011 579489 92504561004 MW-7R SM 5310B-2011 579489 92504561005 MW-8 SM 5310B-2011 579489 92504561006 MW-9 SM 5310B-2011 579489 92504561007 SW-1 SM 5310E-2011 579489 92504561008 SW-2 SM 5310E-2011 579489 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11 /16/2020 01:39 PM without the written consent of Pace Analytical Services, LLC. Page 45 of 48 �aceAnalytical' Document Name: Sample Condition Upon Receipt(SCUR) Document Revised: October 28, 2020 Page 1 of 2 Document F-CAR-CS-033-Rev.07 Issuing Authority: Pace Carolinas Quality Office Laboratory re eiving samples: Asheville Eden❑ Greenwood ❑ Huntersville ❑ Raleigh❑ Mechanicsville❑ Atlanta❑ Kernersville❑ Sample Condition Cliewfi me; W®# • J25®4561 Upon Receipt i �� �'e '0q Project #: Courier: ❑Fed Ex ❑UPS ❑USPS dent ❑ Commercial ❑Pace ❑other: 92504561 Custody Seal Present? []Yes Vo Seals Intact? ❑Yes '�2< Packing Material: ❑Bubble Wrap Bubble Bags ❑None ❑ Other Thermometer: j���/ ❑wet []Blue�R Gun ID: a Type of Ice: Correction Factor: Cooler Temp: Add/Subtract i Cooler Temp Corrected ("C): USDA Regulated Soil ( KN/A, water sample) Did samples originate in a quarantine zone within the United States: CA, NY, or SC (check maps}? Date/Initials Person Examining Contents: !/ Q Biological Tissue Frozen? []Yes❑No ZN/A ❑None Temp should be above freezing to i ❑Samples out of temp criteria. Samples on ice, cooling process has begun Did samples originate from a foreign source {internationally, ❑Yes []No including Hawaii and Puerto Rico)! L}res LJrvU Comments/Discrepancy: Chain of Custody Present? es ❑No ❑NIA 1. Samples Arrived within Hold Time? es ❑No ❑N/A 2. Short Hold Time Analysis (<72 hr.)? ❑Yes o ❑N/A 3. Rush Turn Around Time Requested? ❑Yes o ❑N/A 4. Sufficient Volume? es []No ❑N/A 5. Correct Containers Used? -Pace Containers Used? el -Yes es ❑No ❑No ❑N/A ❑NIA 6. Containers Intact? es [-]NO [—]N/A 7. Dissolved analysis: Samples Field Filtered? (—]Yes ❑No /A 8. Sample Labels Match COC?es -Includes Date/Time/ID/Analysis Matrix: Headspace in VOA Vials (>5-6mm}? Trip Biank Present? Trip Blank Custody Seals Present? [—]Yes ❑Yes ❑Yes ❑No ONO [:)No [—]No _]N/A9. /A /A A 10. 11. COMMENTS/SAMPLE DISCREPANCY CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Project Manager SRF Review: hu" . _` ju-,/6.1. Field Data Required? Des ❑No Lot ID ofsplit containers: Date/Time: �� 41f i Date: f [ ' u Date: ' I i1 D� Page 46 of 48 Document Name: Document Revised: October 28, 2020 ' Sample Condition Upon Receipt(SCUR) Page 2 of 2 Document No.: Authority: c3Ce%�I alytical F-CAR-CS-033-Rev.07 JLIssuing Pace Carolinas Quality Office *Check mark top half of box if pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg **Bottom half of box is to list number of bottles Projectt# --Wa# : 925Q4561 PM: UP Due Date: 11/13/20 CLIENT: 93—ALTAMONT E v a Z n Z m ro a E in a a m a 2 n ? a E 0 fn M a m a Z ro Z d 7 E 0 N a m ¢ ? m i a C a .. .y rl a m u N z a O N CC m a E eN-� 7 a m v V a z i o- E 0 N KI a m a m iu z N v a E N N Q a m u T a Z a E N a a m v S9 a E -o LL ? Z m Z n 4 d ^' .-1 r=i t7 6 v u Q `m ._ r�-I t7 Q a 2 E 4 E o Ln N M l7 < ,N v N E `v .. ry rq L7 4 v x a O N 2 Q E p N M Q7 Q �J Z x z E Q o N m ❑ M LO Q Z _._. CC a 0 E V M 0 4 4 O N a 00 E7 P 0) U > Z .y ¢ E C Q M l7 > d a 07 E CD,n 6 Q1 l7 M a .=. a a ° .10-. Q 0 > a z m '� V Q:i > a m E N h a w n Z a r w E o N a V) m m o 2 E N na] a z o a U a a 0 r-I O C7 Q a g E 0 vi 7 E E 0 C 61 l7 p 1 i � 1 a 5 1 31 3 1 6 1I 3 3 � 1 4 10 11 12 pH Adjustment Log for Preserved Samples Sample 11) Type of Preservative pH upon receipt Date preservation adjusted Time preservation adjusted Amount of Preservative added Lot # Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy Of this form will 6e sent to the North Carolina UFHNR certification Orrice ti.e. Out of hold, incorrect preservative, out of temp, incorrect containers. Page 47 of 48 /..-PaceAnaiytrcal� www,vxC[L�BSt OM Section A Required Client Information: Company, ANCHOR AEA OF NC, PLLC Address: 231 Havwocd Street lEmail: SAMPLE ID One Character per box. lA-Z. D-s r . -1 U Sample Ids must be unique w hALA- Section B Required Project Information: Report To: eZj' Copy To: li ^V%i�!ii rrolecl Name, Lassonde Pappa Project #: 0. MATRIX COOL Dunking Wale, OW v 1 Ce Waler VT wmer ww V Ce wesra Product P = i Lry SoiVSolld SL CA oL ,j STAR Wipe WP Alr AR u O W clhm OT U Tissue TS1 X K w a M a m HATE 1 (n 1 00 0 CHAIN -OF -CUSTODY 1 Analytical Request Document00 The Chain -of -Custody is a LEGAL DOCUMENT. All relevant fields must be completed accurately. 0) Cu Section C Invoice Information: Pa e : Of 1 Attention Company Name: Address. Regulatory A ene Pace Quote. Pace Project Manager: lorri, palton pacelabs_cam, State I Location Pace Profile #: B114 Recuested Analvsis Filtered (YIN) COLLECTED o F U w O Yreselvall � O 2 O y i END a re r E mks z o C T Z t° E w i O LL 4 v a SO a m L � C Q U U s o E G] U n U TIME GATE TIME z: a: z z g L o si ¢ z o O o 9 10 11 0 L � a sa�r5�1 N ADDITIONAL COMMENTS I RELINQUISHEDBYIAFFILIATION DATE I TIME ACCEPTED BY r AFFILIATION DATE I TIME SAMPLE CONDITIONS .�.f, NA U VEIO. IJUu�O. 1 l f W 70 '� IS c. C 6 (fit., — � C r, t - C� 1 L-1 5 5 `( (J PLER NAME AND SIGNATURE PRINT Name of SAMPLER: SIGNATURE of SAMPLER: DATE Signed: `i 1 � Attachment 2 Well Sampling Logs and Instrument Calibration Data Sheet ,� ANCHOR QEA Low -Flow Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Location: Hendersonville, NC Sampling Personnel: - Well ID: MW-4 Screen Interval: 5-15 ft bgs Depth to Water: D , G- ft Measuring Point: TOC Depth of Pump Intake: 11.5 ft Drawdown Set: , I'D ft Pump Used (circle): Peristaltic Bladder Other (describe): Comments: t STD Y. Project Number: Date: Weather: Arrive at Well: Start Time: Sample Time: Finish Sample Time: Leave Well: Well Diameter: C01482-01.01 t 02 I t & (� C 13 3 in Purge Rate: Tagged bottom at: ft Time: Total Volume Purged: Pump Speed: Time DTW (feet) Temp CQ DO (mg/L) Specific Cond. (NS) pH (S.U.) report tt opO. i' S.U. ORP (mV) Turbidity (NTU) me A 03 tf q JIM 10 R4 3,3ar- b t .5 ." r , I -' a. + 1) .� �• LIY�s Sampling Personnel Signature: Date: Notes: Stabilization (3 successive readings, 3 minutes apart): within +/- 10% DO and turbidity,* +/- 3% Conductivity,* +/- 0.1 pH unit' +/- 10 mV for ORP from EPA - Low -Flow (Minimal Drawdown) Groundwater Sampling Procedures, April 1996 (Rev 2017) Samples are analyzed immediately upon collection. pS: micro-Siemen °C: degrees Celsius bgs: below ground surface DO: dissolved oxygen mg/L: milligrams per liter Method Reference: Temperature: SM 2550 B-2010 DO: SM 4500 0 G-2011 mv: millivolt NTU: nephelometric turbidity units ORP: oxidation reduction potential S.U: standard units toc: top of casing Specific conductivity: EPA Method 120.1, Rev. 1982 pH: SM 4500-H' B-2011 Page 1 of 1 ANCHOR Low -Flow Sampling Log Project Name: Lassonde Pappas Groundwater Sampling _ Location: Hendersonville, NC Sampling Personnel: W Well ID: MW-5 Screen Interval: 9-19 ft bgs Depth to Water: a- ft Measuring Point: TOC Depth of Pump Intake: 14 ft Drawdown Set: g �a� ft Pump Used (circle): Peristaltic Bladder Other (describe): Comments: Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Number: C01482-01.01 t 02 Date: it tivit Weather: V dS Arrive at Well: [ 0159- Start Time: Sample Time: Finish Sample Time: Leave Well: Well Diameter. OILin Purge Rate: Total Volume Purged: Tagged bottom at: ILLO ft Time: Pump Speed: i r > W-60 0J Sampling Personnel Signature: 111111e� Notes �,tamhzatlon (3 successive reaaings, s mmuies aparq: wimm +/- ru7o uv ana rurolairy; +/- 17, Lonaucavlry,+/- u.I pn unu; +>- ru my ror VKY from EPA - Low -Flow (Minimal Drowdown) Groundwater Sampling Procedures, April 1996 (Rev 2017) Samples are analyzed immediately upon collection. uS: micro-Siemen mV: millivolt 'C: degrees Celsius NTU: nephelometric turbidity units bgs: below ground surface ORP: oxidation reduction potential DO: dissolved oxygen S.U.: standard units mg1L: milligrams per liter toc: top of casing Method Reference: Temperature: SM 2550 B-2010 Specific conductivity: EPA Method 120.1, Rev. 1982 DO: SM 4500 O G-2011 pH: SM 4500-H' B-2011 Page 1 of 1 ,� ANCHOR QEA` y" Low -Flow Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Location: Hendersonville, NC Sampling Personnel: JV1 Well ID: MW-6 Screen Interval: 5-10 ft bgs Depth to Water: — _ __1 :3 ft Measuring Point: TOC Depth of Pump Intake: 7.5 ft Drawdown Set: ft Pump Used (circle): Peristaltic Bladder Other (describe): Comments: Project Number: Date: Weather: Arrive at Well: Start Time: Sample Time: Finish Sample Time: Leave Well: Well Diameter: CO1482-01.01 t 02 1 l 16 1 av Su"%AtA 0 1 O l 3 �� 5 in Purge Rate: Tagged bottom at: ft Time:JWff Total Volume Purged: Pump Speed: Time DTW (feet) Temp (°C) DO (mg/L) Specific Cond. (pS) PH (S.U.) report to 0.1 SX. (m1) Turbidity (NTU) r 5, 'OLRP `�C �. _ 5.� 14 . - .1 64Lt C5.3 -w i 3 9`S - .a- o 3 3� a � ,a 2_ ,a - a o (01 2- '. a r u U:? 2— a,5 (a , 0 (0 5- Sampling Personnel Signature: Date: k L I G T/ l! Notes: Stabilization (3 successive readings, nutes apart): within +/- 10% DO and turbidity,' +/- 3% Conductivity, +/- 0.7 pH unit +/- 10 mV for ORP from EPA - Low -Flow (Minimal Drawdown) Groundwater Sampling Procedures, April 1996 (Rev 2017) Samples are analyzed immediately upon collection. uS: micro-Siemen mV: millivolt °C: degrees Celsius NTU: nephelometric turbidity units bgs: below ground surface ORP: oxidation reduction potential DO: dissolved oxygen S.U.: standard units mg/L: milligrams per liter Method Reference: Temperature: SM 2550 B-2010 DO:SM 4500 O G-2011 toc: top of casing Specific conductivity: EPA Method 120.1, Rev. 1962 pH:SM 4500-H'8-2011 Page 1 of 1 ANCHOR \4 QEA Low -Flow Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Location: Hendersonville, NC Sampling Personnel: M� Well ID: MW-7R Screen Interval: 5-15 ft bgs Depth to Water. _ M Q G ft Measuring Point: TOC Depth of Pump Intake: 12 ft Drawdown Set: ; O co ft • Pump Used (circle): Peristaltic Bladder Other (describe): Comments: Project Number: Date: Weather: Arrive at Well: Start Time: Sample Time: Finish Sample Time: Leave Well: Well Diameter: C01482-01}.01 t 02 tt ) � ++ � ^� ma y` 3 QC) L b j ih Purge Rate: thN�► Total Volume Purged: Tagged bottom at: TU, . ft Time: _ Pump Speed: Ids - Time DTW (feet) Temp (°C) DO (mg/L) Specific Cond. (pS) PH (S.U.) report to 0.1 S U. ORP (mV) Turbidity (NTU) t D rr. 45[[jj S. r �.Al a si WJ as — 1.60 It 0 W3 ln Personnel Signature: r r� Date: �' n Notes: V Stabilization (3 successive readings, 3 minutes apart): within +/- 70% DO and turbidity; +/- 3% Conductivity, +/- 0.1 pH unit; +/- 70 mV%r ORP from EPA - Low -Flow (Minimal Drowdown) Groundwater Sampling Procedures, April 1996 (Rev 2017) Samples are analyzed immediately upon collection. pS: micro-Siemen °C: degrees Celsius bgs: below ground surface DO: dissolved oxygen mg/L: milligrams per liter Method Reference: Temperature: SM 2550 B-2010 DO: SM 4500 O G-2011 mV: millivolt NTU: nephelometric turbidity units K Irk ORP: oxidation reduction potential ti S.U.: standard units 1a[ toc: top of casing • Specific conductivity: EPA Method 120.1, Rev. 1982 PH: SM 4500-H` B-2011 Page 1 of 1 elANCHOR QEA Low -Flow Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Location: Hendersonville, NC Sampling Personnel: Oil V­ Well ID: MW-g Screen Interval: 3-13 ft bgs Depth to Water: Q ft Measuring Point: TOCuu Depth of Pump Intake: 10.5 ft Drawdown Set: ,tko ft Pump Used (circle): Peristaltic Bladder Other (describe): Comments: _ Tagged bottom at: Amft Time: Project Number: Date: Weather. Arrive at Well: Start Time: Sample Time: Finish Sample Time: Leave Well: Well Diameter: C01482-01.01 t 02 1L 1 (a j )'p tv ty" 4" I Olt O v e� 0 of05 r] in fr Purge Rate: Total Volume Purged_ Pump Speed: Time DTW (feet) Temp (°C) DO (mg/L) Specific Cond. (pS) pH (S.U.) report to 0.1 S.U. ORP (m1) Turbidity (NTU) d 'ram 1613. 5' 3 10r I r� iA Q.p{lA! n O 1 4 �} ! 39— liqV r Le, 31 qF Sampling Personnel Signature: Date: l Notes: Stabilization (3 successive readings, 3 min _ �41within +/- 10% DO and turbidity- +/- 3% Conductivity, +/- 0.1 pH unit; +/- 10 mV for ORP from EPA - Low -Flow (Minimal Drowdown) Groundwater Sampling Procedures, April 1996 (Rev 2017) Samples are analyzed immediately upon collection. pS: micro-Siemen mV: millivolt 'C: degrees Celsius NTU: nephelometric turbidity units bgs: below ground surface ORP: oxidation reduction potential DO: dissolved oxygen S.U.: standard units mg/L: milligrams per liter Method Reference: Temperature: SM 2550 B-2010 DO: SM 4500 0 G-2011 toc: top of casing Specific conductivity: EPA Method 120.1, Rev. 1982 pH: SM 4500-H' B-2011 Page 1 of 1 kZANCHOR QEA Low -Flow Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Location: Hendersonville, NC _ Sampling Personnel: _ Well ID: MW-9 Screen Interval: yakno lr ram- ftbgs Depth to Water. L+. 10 ft Measuring Point: TOC+ uu Depth of Pump Intake: Drawdown Set: ft Pump Used (circle): Peristaltic Bladder Other (describe): Comments: Project Number: Date: Weather: Arrive at Well: Start Time: Sample Time: Finish Sample Time: Leave Well: Well Diameter: C01482-01.01 t 02 L 1 ' Juc P0 W001NIA Tj 1� in Purge Rate: Total Volume Purged: Tagged bottom at: IS, 0 ft Time: Pump Speed: Time DTW (feet) Temp ('Q DO (mg/L) Specific Cond. (pS) PH (S.U.) reportto O.I S.U. ORP (mv) Turbidity (NTU) .0 01 S 5 _ HADI o. 5 55,5 .(01(v 1 3 - 3 - ' 2 2-LiAs �t ! v In Sampling Personnel Signature: Date: +� / Notes: Stabilization (3 successive readings, , s apart): within +/- 70% DO and turbidity +/- 3% Conductivity; +/- 0.7 PH unit, +/- 10 mV for ORP from EPA - Low -Flow (Minimal Drowdown) Groundwater Sampling Procedures, April 1996 (Rev 2017) Samples are analyzed immediately upon collection. pS: micro-Siemen `C: degrees Celsius bgs: below ground surface DO: dissolved oxygen mg/L: milligrams per liter Method Reference: Temperature: SM 2550 B-2010 DO: SM 4500 0 G-2011 mv: millivolt NTU: nephelometric turbidity units ORP: oxidation reduction potential S.0 : standard units toc: top of casing Specific conductivity: EPA Method 120.1, Rev. 1982 pH: SM 4500-H' B-2011 Page 1 of 1 tZANCHOR CIEA Surface Water Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Project Number. C01482-01.01 t 02 Sampling Personnel: Typmy-- Sample Name: SW-1 � Comments: Upstream of site) 5 Lrlri Y Date: Weather: Sample Method: Grab Syringe Pump Bailer-Disp. Other. Time Temp ("C) Dissolved Oxygen (mg/L) Specific Cond. (PS/cm) pH (S.U.) report to 0.1 S.U. Oxidation Reduction Turbidity Potential (mV) (NTU) Comments �acA 1 Sampling Container Number of Containers Requested Analysis 500 mL Plastic 250 mL Plastic Ck(6Nou- 125 mL Plastic Arw"Vtiot r7 Ni 40 mL Glass V) G 1 L Glass Other Vegetation: �D Access: -�V � Sampling Personnel Signature: 12 Date: { L t .. Math—1 Rnfara — VVV Samples are analyzed immediately upon collection. "C: degrees Celsius pS/cm: micro-Siemen per cubic centimeter mg/L: milligrams per liter mV: millivolt NTU: nephelometric turbidity units S.U: standard units Temperature: SM 2550 B-2010 Specific conductivity: EPA Method 120.1, Rev. 1982 DO: SM 4500 O G-2011 pH: SM 4500-H' B-2011 Page 1 of 1 ANCHOR Q� 4-4-4-0 Surface Water Sampling Log Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 Project Name: Lassonde Pappas Groundwater Sampling Project Number. C01482-01.01 t 02 Sampling Personnel: Sample Name: SW-2 Comments: Downstream of site Date: I Weather: Sample Method: Grab Syringe Pump Bailer-Disp. Other. Time Temp (°C) Dissolved Specific Cond. pH (S.U.) Oxygen (mg/L) (PS/cm) report to 0.1 S.U. Oxidation Reduction Potential (mV) Turbidity (NTU) Comments Sampling Container Number of Containers Requested Analysis 500 mL Plastic 1 250 mL Plastic v 125 mL Plastic 40 mL Glass 71 L 1 L Glass Other Vegetation: (� Sampling Personnel Signature: Notes: j Samples are analyzed immediately capon collection. °C: degrees Celsius pS/cm: micro-Siemen per cubic centimeter mg/L: milligrams per liter mv: millivolt NTU: nephelometric turbidity units S.U.: standard units Access: Q �—'— — iA UC Si" a ( Tve4— Date: I (1 L- In Method Reference: Temperature: SM 2550 B-2010 Specific conductivity: EPA Method 120.1, Rev. 1982 DO: SM 4500 O G-2011 pK SM 4500-H' B-2011 Page 1 of 1 ANCHOR QEA Equipment Documentation and Instrument Calibration Data Sheet Anchor QEA of North Carolina, PLLC 231 Haywood Street Asheville, North Carolina 28801 / CALIBRATION DOCUMENTATION Project Name: Li b5 (%Vi �QUp� Gj Person Conducting Calibration: Project Number. Date of Calibration: lk }() Project Location: Date of Field Measurements: k EQUIPMENT DOCUMENTATION Rental sample analysis equipment or meters used to take measurements: ui ment lkpe Brand Serial Number Date of Use Rental Comparrj 13k-�oogao U V Select Turbidimeter: Hach 2100Q (s/n 151006045207) HF Scientific MicroTPW (s/n 200601045) Instrument Reading Instrument Reading (Hach 2100Q) (HF Scientific MicrOTPW) 10 NTU 20 NTU 100 NTU 800 NTU 1,000 NTU 10.0 NTU 0.02 NTU Calibration Expiration r71 ti Date:I Cal: , Cal: /,j � Cal: � Cal: Cal: Cal: Time: �q [� Time:'�l Time: 2 Time: Time: Time: Calibration *Pre -Analysis Meas: �� Time: UT5-17- *Pre -Analysis Meas: Time: Verification: Check (10 NTU): �� Check (10 NTU): *Post -Analysis Meas: �b t �Li] Time: l *Post -Analysis Meas: Time: Check (10 NTU): I Check (10 NTU): YSI Professional Plus Multiparameter Meter (s/n 18B101802) Instrument Readings Calibration Lot No. & Expiration Date Dissolved Oxygen Initial: �� O Cal: lJ uo mmHg: Temperature (°C): Time: pH75.U. Initial yc/ C0 pHmV: `� Cal: pHmV: Time:, �� report to 0.7 S.U. l PH 4 S.U. Initial: , r I , `C y� `l•l pHmV: � Cal: Lt. � pHmV: Time�� U ` report to 0.7 S.U. t PH 10 S.U. Initial: 1,101 pHmV: Cal: 1 0 pHmV: �� Time: _ - (a ��V V� d report to 0.1 S.U. QC* pH 7 S.U. report AM Time- Meas:j /`� �y lQ� S Mid Day Time: Check: PM Time: C eck: �ft+ , ` v to0.iS.U. U'1`d Spec. Cond. wdc) Initial: 1o3o Cal: )000 Time: OTOg �� ( Put. QC*: AM Time:�j Meas: �( Mid Day Time: Check: PM Time: 4 o q Check: PS/CM t/ 1 C) % Recovery= ry,�� ORP O Vy mV Initial:3 v t)l�� , Temperature �"' ll --Il Time: v ` � ()Ojai Signature: Date: Notes: Revision 3, 04/30/20, MHF 1. Electronic equipment calibrated according to the manufacturer's operation manual. 2. Specific Conductivity should be calibrated according to values representative of historic range. 3.Order of Calibration is as follows: Specific Conductivity, pH 7, pH 4, pH 10, DO, ORP, QC checks. 4. QC Acceptable Ranges: pH +/- 0.1 S.U. and Specific Conductivity 10 % of the true value. If QC readings are out of range, the instrument needs to be recalibrated. 5. * QC check must be performed prior to sampling and following completion of sampling, at a minimum. 6. % Recovery = (Value Obtained, pS/cm = True Value, pS/cm) x 100 Method Reference: Temp: SM 2550 8-2010 I Conductivity. EPA Method 720.7 1 DO: SM 4500 0 G-2071 I pH: SM 4500-H+8-2071 I Turbidity: SM 2730 8-207 7 r , rl * Page 1 of 1 ENVIRO—EQUIPMENTINC. YSI PRO+ CALIBRATION DATA SHEET Serial Number: 2 MDate: [ j c} ns ctoe 9 �W Catibrut on Check (Performed At Lub Room Temperuture) SolutionlV'alue ManuLacturer Lot Number Expiration Readh lccttrac ! pH 4.00 AquaPhoenix 01. cc ±0.2, pH 7.00 AquaPhoenix . d 7- pH 10.00 AquaPhoenix ' • =0 Conductivitsr 1000 pis/cm r AquaPhoenix � US/CM 1% ullrtrutrV {rltte .cttciiactterer LrrtNttrnber Eytrattojt Reading cc�s°a ORP 200 mV AquaPhoenix .6111V ±,-01-,1V SolutionlValue Calibration Type Temperature Barometer Readin Readin Accuractr Dissolved Oxygen Saturated Air ���,LW,,4tJ1 Date of last RO. membrane cap replacement: Ic "s Z11-1 Dissolved oxygen accuracy: 0 - 200% air saturation: +2% of reading or 2% air saturation 200% to 500% air saturation. ±6% of readin "Note all standard solution values are at .25°C. ** Temperature Cheek Testo 925 (MST Traceable) , (� -C. ±0.5 C YI Pro+ 'Z-q-0 °C --0.2 C Inspector's Maintenance Notes CHAIN -OF -CUSTODY / Analytical Request Document aceAnalytical" WWW.PkCEUEr.COM The Chain -of -Custody is a LEGAL DOCUMENT. All relevant fields must be completed accurately. SectionlA Section B Section C Required Client Information: Required Project Information: Invoice Information: P8 0 : 1 Of 1 Company: ANCHOR QEA OF NC, PLLC ReportTo: ace ; Atlerrtron Address: 231 Haywood Street Copy To: YVVJ(/,x Ccrnnany Name- Asheville,NC28601 Address: t2e Mato ,. ,.A-` i-lc. Email: �y cj 7 i. ErEo�7 �: Purchase Order#: '+ I Pace Quote: Phone: 1828j707_5827 Fax Project Name: Lassonde Pappas Pace Project Manager: lord.patton pacelabs.com, State!'Logatiml Requested Due Date: Project #: Pace Profile #: 8114 RequIetated.AtialYeWl=iltej' d'W1N 2 MATRIX CODE c0i COLLECTED Z Preservatives 3 Drinking Water DW Water WT m n Waste Water WW Produc P v_ > Q W L Z SAMPLE ID SolVsolid SL q START END I-_ D. ail oL _ ._ One Character per box. Wipe WP w d z m € @ (A•7,0-91,') Air omen AR of oo a i* w Q Dit ?. ?CIDU v Sample Ids must be unique Tissue TS x U a, v @ II o m a co if 0. a N _ O t Q -` F — < ¢ DATE TIME DATE TIME 4cc ur O _ Z = U = z z m O m LL L 0 E ¢ z ❑ - O 1- O > m � � �IH�®l■m■�I■■■Il■1 ® �■11®lam ■�■�I■■■�1■1! Pi- ADOMONALCC MMENTS RELIWIUMNED BY ! AFFlLIATION PATE - iYME ACCEPTED BY i AmL1AT1ON DATE TIME 5AMPLE CONDUION3 PLER NAME AND SIGNATURE' c PRINT Name of SAMPLER: a n m o @ m E SIGNATURE of SAMPLER: ` DATE Signed: g j r w m m U Attachment 3 DEQ GW-59A — Compliance Report Form GW-59A COMPLIANCE REPORT FORM Permit # (Submit one each monitoring period with GI1'-59 fornis.) 1 Enter date monitoring results were due. ( ) Will this monitoring report (GW-59 and GW-59A) YES NO be submitted after the established due date? 2 Was any required information missing on the GW-59 report forms? YES NO IF the answer to question 1 or 2 is "YES", list in the space provided below the well identification number(s) and explain the problems encountered in obtaining the required information. 3 Are any of the monitor wells in need of repair or maintenance (damaged casing, unlocked or missing cap, missing YES NO identification plate, area overgrown, etc.)? If the ansiver is " 3 es ", contact the Regional Office for guidance. 4 Are any monitored constituents equal to or above the established standards? YES NO If the answer to question 4 is "NO", skip to section 8. If the answer to question 4 is "YES" list the affected wells individually with constituent(s) and concentration(s) exceeding standards in the space provided below: 5 For the constituents identified in question 4 above, have standards been exceeded previously for the YES NO same constituent(s) in the same well(s) in the last two years? If the answer to question 5 is "NO", skip to section 8. If the answer to question 5 is "YES", list in the space provided below, each well with constituent(s) exceeding standards, concentrations) reported, and sample collection date for each occurrence (for the last two years). 6 Are the monitoring wells listed in section 5 located at or beyond the review boundary? YES NO If the answer is "YES", a groundwater quality problem may be occurring. CONTACT THE REGIONAL OFFICE IMMEDIATELY FOR GUIDANCE. If the answer is "NO", monitoring wells may be improperly located; contact the Regional Office. 7 Is the permittee implementing previously approved actions required by the Division involving this YES NO groundwater quality problem? If the answer to question 7 is "YES", describe those actions in the space provided below. If the answer to question 7 is "NO", contact the Regional Office within 90 days; an evaluation may be required to determine the impact the waste disposal system is having at the review and compliance boundaries surrounding this facility. Failure to do so may subject the permittee to a Notice of Violation, fines, and/or penalties. 8 The person completing this portion (GW-59A) of the monitoring report should sign below and submit this form with G W-59 forms for required wells to the address provided at the top of the current G W-59 form. I hereby acknowledge that the above information was evaluated and the information submitted in this report (Compliance Report GW-59A) is true and complete to the best of my knowledge. Signature of Permittee (or Authorized Agent) Date GR'-59A 12/8/2003 Attachment 4 DEQ GW-59 — Groundwater Quality Monitoring: Compliance Report Forms SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 / 31 / 2 0 2 6 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ❑ Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): Date sample collected: FIELD ANALYSES: WAS Well Depth: ft. Well Diameter: in. pH 00000: units Temp. 000lo: °C DRY at Depth to Water Level 82546: ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: check Volume of water pumped/bailed before sampling: gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report Laboratory Name: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (or Authorized Agent) (Date) SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ❑ Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 64 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): Date sample collected: FIELD ANALYSES: WAS Well Depth: ft. Well Diameter: in. pH 00000: units Temp. 000lo: °C DRY at Depth to Water Level 82546: ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: check Volume of water pumped/bailed before sampling: gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report Laboratory Name: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L Tetrachloroethene - 0.80 pg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L Trichloroethene - 1.0 pg/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (or Authorized Agent) (Date) SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ❑ Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): Date sample collected: FIELD ANALYSES: WAS Well Depth: ft. Well Diameter: in. pH 00000: units Temp. 000lo: °C DRY at Depth to Water Level 82546: ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: check Volume of water pumped/bailed before sampling: gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report Laboratory Name: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (or Authorized Agent) (Date) SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ❑ Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): Date sample collected: FIELD ANALYSES: WAS Well Depth: ft. Well Diameter: in. pH 00000: units Temp. 000lo: °C DRY at Depth to Water Level 82546: ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: check Volume of water pumped/bailed before sampling: gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report Laboratory Name: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (or Authorized Agent) (Date) SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ❑ Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): Date sample collected: FIELD ANALYSES: WAS Well Depth: ft. Well Diameter: in. pH 00000: units Temp. 000lo: °C DRY at Depth to Water Level 82546: ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: check Volume of water pumped/bailed before sampling: gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report Laboratory Name: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (or Authorized Agent) (Date) SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ❑ Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): Date sample collected: FIELD ANALYSES: WAS Well Depth: ft. Well Diameter: in. pH 00000: units Temp. 000lo: °C DRY at Depth to Water Level 82546: ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: check Volume of water pumped/bailed before sampling: gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report Laboratory Name: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (or Authorized Agent) (Date) Attachment 3 DEQ GW-59A — Compliance Report Form GW 59A COMPLIANCE REPORT FORM Permit # WQ0004797 (Srrhnrit one each nronitnring period with Gil 59 jorna ) 1 Enter date monitoring results were due. (12 /31/2020) Will this monitoring report (GW-59 and GW-59A) YES NO be submitted after the established due date? X 2 Was any required information missing on the GW-59 report forms? YES NO IF the answer to question 1 or 2 is "YES, list in the space provided below the well identification number(s) and explain the problems encountered in obtaining the required information. 3 Are any of the monitor wells in need of repair or maintenance (damaged casing, unlocked or missing cap, missing YES NO identification plate, area overgrown, etc.)? If the answer is 1es ", contact the Regional Office for guidance. X 4 Are any monitored constituents equal to or above the established standards? YES NO if the answer to question 4 is "NO", skip to section 8. If the answer to question 4 is "YES" list the affected wells individually with constituent(s) and concentrations) exceeding standards in the space provided below: Nitrate (2L = 10 mg/L): MW-7R0 13.0 mg/L Fecal Coliform (Total Coliform 2L standard = 1.0 CFU/100mL): MW 5C 8.0 CFU/100mL, MW 6q 3.0 CFU/100ML, MW 8: 14.0 and MW-90 16.0 5 For the constituents identified in question 4 above, have standards been exceeded previously for the YES NO same constituent(s) in the same well(s) in the last two years? X If the answer to question 5 is "NO", skip to section 8. If the answer to question 5 is "YES", list in the space provided below, each well with constituent(s) exceeding standards, concentrations) reported, and sample collection date for each occurrence (for the last two years). Nitrate Fecal Coliform Fecal Coliform Fecal Coliform Fecal Coliform MW-7R (mg/L) MW 5 (CFU/100mL) MW-6 (CFU)100mL) MW-8 (CFU/l00mL) MW-9 (CFU/100mL) 05/21/19: 20.2 05/21/19: 7.0 05/21/19: 23.0 05/21/19: <10.0 05/21/19; <10.0 11/14/19: 17.1 11/14/19: 7.0 11/14/19: 44.0 11/14/19: 2.0 11/14/19: <1.0 05/06/20: 21.5 05/06/20: 8.0 05/06/20: 3.0 05/06/20: <1.0 05/06/20: <1.0 11/06/20: 13.0 11/06/20: 8.0 11/06/20: 3.0 11/06/20: 14.0 11/06/20: 16.0 6 Are the monitoring wells listed in section 5 located at or beyond the review boundary? YES NO X If the answer is "YES", a groundwater quality problem maybe occurring. CONTACT THE REGIONAL OFFICE IMMEDIATELY FOR GUIDANCE. If the answer is "NO", monitoring wells maybe improperly located; contact the Regional Office. 7 Is the permittee implementing previously approved actions required by the Division involving this YES NO groundwater quality problem? X If the answer to question 7 is "YES", describe those actions in the space provided below. If the answer to question 7 is "NO" contact the Regional Office within 90 days; an evaluation may be required to determine the impact the waste disposal system is having at the review and compliance boundaries surrounding this facility. Failure to do so may subiect the permittee to a Notice of Violation, fines, and/or penalties. Fecal coliform should not be attributable to site operations. Historical monitoring of an on -site tributary of Mud Creek has found high levels of fecal coliform. The surface water sample collected in Mud Creek upstream of the site had higher fecal coliform concentrations than the sample collected downstream of the site. High nitrate concentrations may be attributable to the frequent flooding of Mud Creek. As a proactive approach to avoid introducing additional nitrogen into soils at the facility, Clement Pappas has implemented the practice of baling harvested fescue and removing it from the irrigation fields, instead of mowing it and allowing it to decompose. g The person completing this portion (GW-59A) of the monitoring report should sign below and submit this form with GW-59 forms for required wells to the address provided at the top of the current GW-59 form. I hereby acknowledge that the above information was evaluated and the information submitted in this report (Compliance Report GW-59A) is true and complete to the best of my knowledge. Signature of Permittee (or Authorized Agent) Date GN1 59 \ 12/8/2003 Attachment 4 DEQ GW-59 — Groundwater Quality Monitoring: Compliance Report Forms SUBMIT FORM ON YELLOW PAPER ONLY GROUNDWATER QUALITY MONITORING: • AD . DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM � 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 / 31 / 2 0 2 6 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑Remediation: Infiltration Gallery IN Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Irrigation Area No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW- 4 Date sample collected: 11 / 0 6 / 2 0 2 0 FIELD ANALYSES: WAS Well Depth: 18 _ 2 pft. Well Diameter: 2 in. pH 00400:5 . 30 units Temp. 000to: 18 . 1 oC DRY at Depth to Water Level 82546: 8 . 02 ft. below measuring point Screened Interval: r ft. to ft. Spec. Cond. 00094: 230.4 µMhos time of Measuring Point is 2 . 43 ft. above land surface Relative M.P. Elevation: 2063 . 77 ft. Odor 00085: none sampling,check Volume of water um ed/bailed before sampling: 0 . 4 0 p p p g: *screened interval is relative to land surface gallons Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report LaboratoryName: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 < 1 . 0 /100mL Nitrate (NO3) as N 00620 0.73 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 < 0 . 0 5 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 148 mg/L Al - Aluminum of im mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC omn 2.8 mg/L Ca - Calcium 00916 mg/L Chloride 00940 6.9 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 rng/L Hg - Mercury 71900 ug/L Lab Report Attached? ® Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia com < 0 . 10 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese o1055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% WAGE 4JV01595),,1 f 4G _)(1Vtr4,V,+G-eve_ Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Signature of Permittee (Date) SUBMIT FORM ON YELLOW PAPER ONLY GROUNDWATER QUALITY MONITORING: . ., DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM • .. 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919.807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 828 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Irrigation Area No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from P-0 SAMPLING INFORMATION MW- 5 If WELL WELL ID NUMBER (from Permit): Date sample collected: 11 / 0 6 / 2 0 FIELD ANALYSES: WAS Well Depth: 18 _ - nft. Well Diameter: 2 in. pH 00400: 5 .65 units Temp. oomo: 18 •2 °C DRY at Depth to Water Level 82546: 8 , 9 0 ft. below measuring point Screened Interval: 9 * ft. to 19 * ft. Spec. Cond. 00094: 64.5 µMhos time of Measuring Point is 3 . 0 0 g ft. above land surface Relative M.P. Elevation: 2085. 6o ft. Odor 000a5: none sampling, check Volume of water pumped/bailed before sampling: 0 . 3 6 gallons screened interval is relative to land surfac'Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report LaboratoryName: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 8.0 /100mL Nitrate (NO3) as N 00620 <0 . 040mg/L Zn -Zinc 01092 m9 /L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0 . 0 6 0 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 61.0 mg/L AI - Aluminum 01105 mg/L Tetrachloroethene - 0.80 pg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L Trichloroethene - 1.0 pg/L TOC 00680 4.6 mg/L Ca - Calcium 00916 mg/L Chloride 00940 6.9 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ® Yes (1) ❑ No (0) Specific Conductance o0095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 < 0 . 10 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% WA PF_ AAIDE(ZScrl kA r," (xblA(re%� Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 Permittee (or Authorized Agent) SUBMIT FORM ON YELLOW PAPER ONLY GROUNDWATER QUALITY MONITORING: DEPARTMENT OF ENVIRONMENT 8, NATURAL RESOURCES DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2 02 6 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery IN Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Irrigation Area No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION MW- 6 If WELL WELL ID NUMBER (from Permit): Date sample collected: 11 / 0 6 / 2 02 0 FIELD ANALYSES: WAS Well Depth: 11 —5a ft. Well Diameter: 2 in. pH 00400: 5 • 23 units Temp. 000lo: 16 .4 °C DRY at Depth to Water Level 82546: 5 . 3 3 ft. below measuring point Screened Interval: 5* ft. to 10 * ft. Spec. Cond. 00094: 202.6 µMhos time of Measuring Point is 3 . 0 0 ft. above land surface Relative M.P. Elevation: 2061.17 ft. Odor 00085: none sampling, check Volume of water um ed/bailed before sampling: 0 _ ] tJ *screened interval is relative to land surface p p p g: gallons Appearance here: Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report LaboratoryName: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1o51 ug/L Coliform: MF Fecal 31616 3.0 /100ml- Nitrate (NO3) as N 00620 3.2 mg/L Zn -Zinc 01092 mg/L Coliform: M F Total 31504 /100ml- Phosphorus: Total as P 00665 < 0 . 0 5 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 139 mg/L All - Aluminum o1105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 2 . 6 mg/L Ca - Calcium oo916 mg/L Chloride 00940 12 . 5 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ® Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 < 0 . 10 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N: Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remedlation Systems Only •Total• • certify that, to the best of my knowledge and belief, the information submitted in this report is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a DWR-certified laboratory, I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. ittee (or Authorized Agent) Name and Title - Please print or type Signature of Permittee (or GW-59 Rev.8/2013 (Date) Z SUBMIT FORM ON YELLOW PAPFR ON[ Y GROUNDWATER QUALITY MONITORING: .... : DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM .. 11617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2026 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery ® Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Irrigation Area No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION MW- 7R If WELL WELL ID NUMBER (from Permit): Date sample collected: 11 / 0 6 / 2 0 FIELD ANALYSES: WAS Well Depth: 17 _ -� 7 ft. Well Diameter: 2 in. pH 00400: 5 . 54 units Temp. 000lo: 14. 3 °C DRY at Depth to Water Level 82546: 10 . 0 Sft. below measuring point Screened Interval: 5 ft.* to 15 ft* Spec. Cond. 00094: 311.6 µMhos time of Measuring Point is 3 . 0 0 ft. above land surface Relative M.P. Elevation: 2062.86 ft. Odor 00085: none sampling, check Volume of water um ed/bailed before sampling: 0 . 4 7 ;screened interval is relative to land p p p g: gallons surface Appearance here: Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report LaboratoryName: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1051 ug/L Coliform: MF Fecal 31616 <1 , p /100mL Nitrate (NO3) as N 00620 13.0 mg/L Zn -Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 < 0 - 0 5 mg/L (Note: Use WIN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 205 mg/L Al - Aluminum oil o5 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 1.7 mg/L Ca - Calcium 00916 mg/L Chloride 00940 17.8 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ® Yes (1) ❑ No (0) Specific Conductance 000s5 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 <0 . 10 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NHS as N; Ammonia Nitrogen, Total) Mn - Manganese o1 o55 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% ittee (or Authorized Agent) Name GW-59 Rev.8/2013 type of Permittee (or Authorized Agent) SUBMIT FORM ON YELLOW PAPER ONLY GROUNDWATER QUALITY MONITORING: • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES COMPLIANCE REPORT FORM DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 3 1 2 0 2 6 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery IN Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Irrigation area No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION MW 8 If WELL WELL ID NUMBER (from Permit): Date sample collected: 11 / 0 6 / 2 0 FIELD ANALYSES: WAS Well Depth: 13—a eft. Well Diameter: in. e pH ooaoo: 6 . 34 units Temp. 000�o: 14 . 5 C DRY at Depth to Water Level 82546: 8 _ 3 7 ft. below measuring point Screened Interval: 3 ft* to 13 ft* Spec. Cond. 00094: 229.0 µMhos time of Measuring Point is 3 . 0 0 ft. above land surface Relative M.P. Elevation: 2060.80 ft. Odor 000m: none sampling, check Volume of water um ed/bailed before sampling: 0 _ 6 Q *screened interval is relative to land p p p g: gallons surface Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report LaboratoryName: Pace Analytical Services Certification No. 37712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1051 ug/L Coliform: MF Fecal 31616 14.0 /100mL Nitrate (NO3) as N 00620 2.4 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100ml- Phosphorus: Total as P 00665 < 0 . 0 5 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 127 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 2.8 mg/L Ca - Calcium 00916 mg/L Chloride 00940 2.3 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ® Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 < 0 . 10 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Agent) Name and Title - Please print or type GW-59 Rev.8/2013 N� (rep__ 1 Signature of Permittee (or Authorized Agent) (Date) SUBMIT FORM ON YELLOW PAPER ONLY GROUNDWATER QUALITY MONITORING: . DEPARTMENT OF ENVIRONMENTS NATURAL RESOURCES DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919.807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7 31 2 0 2 6 Facility Name: Clement Pappas Non -Discharge WQ0004797 UIC Permit Name (if different): NPDES Other Facility Address: 485 Brookside Camp Road TYPE OF PERMITTED OPERATION BEING MONITORED Hendersonville NC 28792 County Henderson ❑ Lagoon ❑ Remediation: Infiltration Gallery IN Spray Field ❑ Remediation: Contact Person: Mrs. Tracy Wolfe Telephone#: 8 2 8 - 3 2 9 - 6 6 4 7 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Irrigation area No. of wells to be sampled: 6 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW- 9 Date sample collected: 11 / 0 6 / 2 0 FIELD ANALYSES: WAS Well Depth: 18 - 1 ft. Well Diameter: 2 in. pH 00400: 4 • 93 units Temp. 000lo: 18.4 °C DRY at Depth to Water Level 82546: 4 . 10 ft. below measuring point Screened Interval: 3 ft* to 13 ft* Spec. Cond. oo0sa: 55 .4 µMhos time of Measuring Point is 3 . 00 ft_ above land surface Relative M.P. Elevation: 2060.23 ft. Odor000m: none sampling, check Volume of water pumped/bailed before sampling: 0.30 gallonsscreened interval is relative to land surfac'Appearance here:❑ Samples for metals were collected unfiltered: ❑ YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: varies; see analytical report LaboratoryName: Pace Analytical Services Certification No. 3 7712 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 rng/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 16.0 /100mL Nitrate (NO3) as N 00620 0.043 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100ml- Phosphorus: Total as P 00665 0.095 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 88 - 0 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 4.5 mg/L Ca - Calcium oo916 mg/L Chloride 00940 1.4 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ® Yes (1) ❑ No (0) Specific Conductance o0095 µMhos K - Potassium 00937 mg/L method # Total Ammonia 00610 < 0 - 10 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L ,method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.8/2013 of Permittee (or Authorized 1 Z/ (Date)