Loading...
HomeMy WebLinkAbout20061804 Ver 36_Rip Rap Outlet Protection_20201231Rip-Rap Outlet Protection Pipe #Outlet protection 1 Known: 18"RCP Q10 =11.62 CFS V10 =6.58 FPS Min. Required: La =8 FT W =10 FT 3d0 =5 FT d50 =0.4 (Rip Rap Size, FT) *Use Class B Rip Rap over Mirafi 140N 18 " in depth. Rip-Rap Outlet Protection Pipe #Outlet protection 2 Known: 42"RCP Q10 =61.2 CFS V10 =6.3 FPS Min. Required: La =21 FT W =25 FT 3d0 =11 FT d50 =0.7 (Rip Rap Size, FT) *Use Class B Rip Rap over Mirafi 140N 18 " in depth. Rip-Rap Outlet Protection Pipe #Outlet protection 3 Known: 36"RCP Q10 =58.76 CFS V10 =8.3 FPS Min. Required: La =21 FT W =24 FT 3d0 =9 FT d50 =0.6 (Rip Rap Size, FT) *Use Class B Rip Rap over Mirafi 140N 18 " in depth. Rip-Rap Outlet Protection Pipe #Outlet protection 4 Known: 42"RCP Q10 =78.91 CFS V10 =8.21 FPS Min. Required: La =22 FT W =26 FT 3d0 =11 FT d50 =0.7 (Rip Rap Size, FT) *Use Class B Rip Rap over Mirafi 140N 18 " in depth. Rip-Rap Outlet Protection Pipe #Outlet protection 5 Known: 36"RCP Q10 =42.36 CFS V10 =5.98 FPS Min. Required: La =20 FT W =23 FT 3d0 =9 FT d50 =0.6 (Rip Rap Size, FT) *Use Class B Rip Rap over Mirafi 140N 18 " in depth. Rip-Rap Outlet Protection Pipe #Outlet protection 6 Known: 24"RCP Q10 =22.76 CFS V10 =7.25 FPS Min. Required: La =14 FT W =16 FT 3d0 =6 FT d50 =0.5 (Rip Rap Size, FT) *Use Class B Rip Rap over Mirafi 140N 18 " in depth.