HomeMy WebLinkAboutWQ0037555_STFRPT_20210104State of North Carolina Department of Environmental Quality Division of Water Resources Water Quality Permitting Regional Staff Report FORM: APSRSR 04-10 Page 1 of 4 January 4, 2020 To: DWR Water Quality Permitting Section Central Office Application No.: WQ0037555 Attn: Lauren Plummer Regional Login No.: From: Mikal Willmer Asheville Regional Office I. GENERAL SITE VISIT INFORMATION 1. Was a site visit conducted? Yes or No a. Date of site visit: 03/11/19- Infiltration basin not currently in use, but visited site in 2019 during NPDES inspection (NC0059200) b. Site visit conducted by: Mikal Willmer c. Inspection report attached? Yes or No (NPDES Inspection in LF , ND compliance inspection not conducted, only visited the facility components-facility not in use. ) ND Inspection will occur later this month. d. Person contacted: Freddie Boan, General Manager and their contact information: 828.226.9161 e. Driving directions: WWTP: Take I-40 W from Swannanoa and take exit 27 towards Sylva, stay on US- 74 W for approximately 21 miles to Exit 85. Follow NC-107 for 26 miles and then turn right onto N Norton Rd. Turn right onto fenley forest trail. The WWTP is 0.3 miles on the right. Infiltration Basin- Take the left immediately before you reach fenley forest trail and then a left at the T intersection. The infiltration basin is approximately 0.1 miles from the intersection. II. PROPOSED FACILITIES FOR NEW AND MODIFICATION APPLICATIONS 1. Facility Classification: (Please attach completed rating sheet to be attached to issued permit) 2. Are the new treatment facilities adequate for the type of waste and disposal system? Yes or No If no, explain: 3. Are site conditions (soils, depth to water table, etc) consistent with the submitted reports? Yes No N/A If no, please explain: 4. Do the plans and site map represent the actual site (property lines, wells, etc.)? Yes No N/A If no, please explain: 5. Is the proposed residuals management plan adequate? Yes No N/A If no, please explain: 6. Are the proposed application rates (e.g., hydraulic, nutrient) acceptable? Yes No N/A If no, please explain: 7. Are there any setback conflicts for proposed treatment, storage and disposal sites? Yes or No If yes, attach a map showing conflict areas. 8. Is the proposed or existing groundwater monitoring program adequate? Yes No N/A If no, explain and recommend any changes to the groundwater monitoring program: 9. For residuals, will seasonal or other restrictions be required? Yes No N/A If yes, attach list of sites with restrictions (Certification B) DocuSign Envelope ID: 38BD4323-7AAF-4CE6-B547-F8BBFEAEDC03 FORM: APSRSR 04-10 Page 2 of 4 III. EXISTING FACILITIES FOR MODIFICATION AND RENEWAL APPLICATIONS 1. Are there appropriately certified Operators in Charge (ORCs) for the facility? Yes No N/A WW-II Facility rating. ORC: Michael Beck Certificate #:7930 Backup ORC: Robert Barr Certificate #:8928 2. Are the design, maintenance and operation of the treatment facilities adequate for the type of waste and disposal system? Yes or No If no, please explain: Unknown, High-rate infiltration basin has not been put into use. The WWTP has had structural and manufactural defects since being put into operation. Facility is still struggling to consistently comply with NPDES permit limits. 3. Are the site conditions (e.g., soils, topography, depth to water table, etc) maintained appropriately and adequately assimilating the waste? Yes or No N/A If no, please explain: Unknown, facility has not been used. During last site visit vegetation appeared maintained and staff attempt to sample monitoring wells, but they are consistently dry. 4. Has the site changed in any way that may affect the permit (e.g., drainage added, new wells inside the compliance boundary, new development, etc.)? Yes or No If yes, please explain: Wells are dry- regional office was not contacted before drilling, site is vegetated (originally permitted without vegetation). 5. Is the residuals management plan adequate? Yes or No N/A If no, please explain: Solids are hauled to Franklin WWTP 6. Are the existing application rates (e.g., hydraulic, nutrient) still acceptable? Yes or No N/A If no, please explain: 7. Is the existing groundwater monitoring program adequate? Yes No N/A If no, explain and recommend any changes to the groundwater monitoring program: Unable to sample due to wells being dry. 8. Are there any setback conflicts for existing treatment, storage and disposal sites? Yes or No If yes, attach a map showing conflict areas. 9. Is the description of the facilities as written in the existing permit correct? Yes or No If no, please explain: Need clarification on what is installed. A to C certification sent to NPDES Unit in 2016 does not match what is listed in the ND permit. Infiltration basin was also constructed with a vegetative cover. Engineer has yet to submit a signed certification letter for ND portion of the facility. MW-4 is not installed and should be removed from the permit. There are two downgradient wells W2 & W3. W1 is upgradient. 10. Were monitoring wells properly constructed and located? Yes No N/A If no, please explain: ARO hydrogeologist was not notified before well construction. Wells are consistently dry when staff attempt to sample. Our records indicate we have still not received the GW-1 well construction forms. 11. Are the monitoring well coordinates correct in BIMS? Yes No N/A If no, please complete the following (expand table if necessary): Still show as “proposed” in BIMS, no record of GW-1s being submitted. No coordinates listed in BIMS. Application lists MW-4, which was not installed, should be MW-3. Monitoring Well Latitude Longitude ○ ′ ″ - ○ ′ ″ ○ ′ ″ - ○ ′ ″ ○ ′ ″ - ○ ′ ″ ○ ′ ″ - ○ ′ ″ ○ ′ ″ - ○ ′ ″ 12. Has a review of all self-monitoring data been conducted (e.g., NDMR, NDAR, GW)? Yes or No Please summarize any findings resulting from this review: No NDMR data has been collected, but facility has had consistent NPDES permit limit exceedances. No data on GW-59s because wells are dry. DocuSign Envelope ID: 38BD4323-7AAF-4CE6-B547-F8BBFEAEDC03 FORM: APSRSR 04-10 Page 3 of 4 13. Are there any permit changes needed in order to address ongoing BIMS violations? Yes or No If yes, please explain: 14. Check all that apply: No compliance issues Current enforcement action(s) Currently under JOC Notice(s) of violation Currently under SOC Currently under moratorium Please explain and attach any documents that may help clarify answer/comments (i.e., NOV, NOD, etc.) Facility never submitted all or the correct requested additional information for modification application in 2018. 15. Have all compliance dates/conditions in the existing permit been satisfied? Yes No N/A If no, please explain: Previous modification application was returned due to missing items from the additional information request. Most of these items still appear to be missing. The modification submitted by Mr. Burgin in 2020 appears to be a resubmittal of information generated in 2014. 16. Are there any issues related to compliance/enforcement that should be resolved before issuing this permit? Yes No N/A If yes, please explain: Yes, issues noted above. IV. REGIONAL OFFICE RECOMMENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? Yes or No If yes, please explain: No issue if all requested items are submitted. 2. List any items that you would like Non-Discharge Central Office to obtain through an additional information request: Item Reason Updated O&M Plan Modification submitted in 2018 did not appear to contain updated O&M Plan to address maintaining vegetative cover on Infiltration basin. Most recent submittal is dated November 2014. Information does not appear to have been submitted with 2020 renewal/modification. (02T.0707) GW-1 Provide GW-1 forms for monitoring wells drilled with correct designations and coordinates- (BIMS lists MW-1, MW-2 & MW4. Trillium installed MW1, 2 & 3. These were never submitted, as requested in 2018. Updated Site Map Site Map submitted in 2018 does not appear to identify/label any streams, ponds or natural drainage features within 500’ of all facilities. The 500’ boundary depicted appears greater than 500’ on the east and west side of the infiltration basin. Wetted perimeter is not labeled. The property owners within 500’ are not identified on the map, only parcel locations. Clearly label and identify all required items within the map’s legend. (02T.0704(d)) Engineering Certification Engineering certification does not appear to have ever been submitted. Ensure component descriptions are accurate as there have been discrepancies from the originally listed components. Phase I installed WWTP components were designed for 80,000 gpd not 104,000 gpd according to previous emails with Mr. Burgin and engineering plans. Currently the facilities combined disposal volume is 40,000 gpd under the NPDES permit and 17,533 gpd to the one constructed infiltration basin for a total permitted flow of 57,533 gpd between both permits. 3. List specific permit conditions recommended to be removed from the permit when issued: Condition Reason DocuSign Envelope ID: 38BD4323-7AAF-4CE6-B547-F8BBFEAEDC03 FORM: APSRSR 04-10 Page 4 of 4 4. List specific special conditions or compliance schedules recommended to be included in the permit when issued: Condition Reason 5. Recommendation: Hold, pending receipt and review of additional information by regional office Hold, pending review of draft permit by regional office Issue upon receipt of needed additional information Issue Deny (Please state reasons: ) 6. Signature of report preparer: Signature of WQROS regional supervisor: Date: V. ADDITIONAL REGIONAL STAFF REVIEW ITEMS 1. During the site visit in 2019 and after reviewing submitted drawings and maps, it was noted a force main was routed to one of the golf course ponds from the WWTP. This force main was not permitted in either the NPDES modification and/or the non-discharge application. A reclaimed application was never submitted. Additionally, the freshwater irrigation pond is unlined and has a standpipe that discharges to Norton Creek WS-III Tr. Trillium staff were directed to lockout the valve to the pond from the WWTP. Staff were informed a discharge to this pond from the WWTP would be considered a discharge without a valid permit and in violation of state statute. Trillium was provided a reclaimed use application and advised of the steps necessary to utilize reclaimed quality wastewater for golf course irrigation. 2. Currently the ARO is not requesting redrilling of the wells. The issue of dry wells during sampling will be reassessed if/when Trillium begins using the high-rate infiltration basin. DocuSign Envelope ID: 38BD4323-7AAF-4CE6-B547-F8BBFEAEDC03 1/4/2021 Certificate Of Completion Envelope Id: 38BD43237AAF4CE6B547F8BBFEAEDC03 Status: Completed Subject: Please DocuSign: WQ0037555_STFRPT_20210104.docx Source Envelope: Document Pages: 4 Signatures: 2 Envelope Originator: Certificate Pages: 2 Initials: 0 Mikal Willmer AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-05:00) Eastern Time (US & Canada) 217 W. Jones Street Raleigh, NC 27699 Mikal.willmer@ncdenr.gov IP Address: 149.168.204.10 Record Tracking Status: Original Jan 4, 2021 | 10:28 Holder: Mikal Willmer Mikal.willmer@ncdenr.gov Location: DocuSign Security Appliance Status: Connected Pool: StateLocal Storage Appliance Status: Connected Pool: North Carolina Department of Environmental Quality Location: DocuSign Signer Events Signature Timestamp Mikal Willmer mikal.willmer@ncdenr.gov Environmental Specialist North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 149.168.204.10 Sent: Jan 4, 2021 | 10:34 Viewed: Jan 4, 2021 | 10:34 Signed: Jan 4, 2021 | 10:34 Electronic Record and Signature Disclosure: Not Offered via DocuSign G. Landon Davidson landon.davidson@ncdenr.gov Asheville Regional Office, Regional Supervisor DEQ, Division of Water Resources, Water Quality Regional Operatoins Security Level: Email, Account Authentication (None) Signature Adoption: Uploaded Signature Image Using IP Address: 149.168.204.10 Sent: Jan 4, 2021 | 10:34 Viewed: Jan 4, 2021 | 10:40 Signed: Jan 4, 2021 | 10:40 Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted Jan 4, 2021 | 10:34 Certified Delivered Security Checked Jan 4, 2021 | 10:40 Signing Complete Security Checked Jan 4, 2021 | 10:40 Completed Security Checked Jan 4, 2021 | 10:40 Payment Events Status Timestamps