HomeMy WebLinkAboutWQ0029911_Application_20060301CRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3
Application Number: u/�oo
f
(to be completed by DWQ) �■ 299
1. Owner.
1 a. Town of Wadesboro
Full Legal Name (company, municipality, HOA, utility, etc.)
Z
I b. Don McRode, Mayor
0
Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!)
1 c. The legal entity who will own this system is:
Individual ❑ Federal ® Municipality ❑ State/County❑ Private Partnership ❑ Corporation ❑ Other (specify):
1 d. 107-A East Wade Street le. Wadesboro
0
Street Address City
LL
_
Z
1f. North Carolina 1g. 28170
Z
State Zip Code _
0
1 h. 704 694-5171 '1 i. 1 j. wadesboromanager@alltel.net
Telephone Facsimile E-mail
(�
2. Project (Facility) Infonnation:
J
is
2a. Wadesboro Hwy 74 Sewer Extension 2b. Anson
CL
Brief Project Name (permit will refer to this name) County Where Project is Located
Q
!3. Contact Person:_
Q
3a. Bradley H. Bucy
Name and Affiliation of Someone Who Can Answer Questions About this Application
3b. 704-342-3000, (C) 704-512-9008 3c. bbucy@hobbsupchurch.com
Phone Number E-mail
1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.:
For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another
phase, changing line size/length, etc.). Only include the modified information in this permit application - do not
duplicate project information in B(7) and B(10-11) tit has already been included in the original permit.
2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a))
2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one
❑ Retaining Ownership (i.e. store, church, single office, etc.) or, ❑ Public Utility (Instruction 111)
Z
❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV)
0
❑ Selling units (lots, townhomes, etc. - go to Item B(2b))
I--
3. Anson County
2
Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project
—W
HOBBS, RC�-!&ASSOCIq`I'£TS� P.A BB�ILT
CO. BOLTING 300 .N . BR Brawk Bmldet and Tana coopaoy
P.O. BOX 1737.300 S.W. BROAD STREET
SOUTHERN PINES. NC 28388 W112/531
(910)692-5616
xactly Four hundred and no / 100 Dollars
DATE AMOUNT
2/10/2006 $400.00
0
a
m
AY
OTHE NC DENR - Division of Water Quality pp
iRDER ID ER 90 DAYS L!�
�F:
NC
AUTHORIZED SIGNATURE
II80 506040 l:0 5 3 10 L L 2 L1: L86 L000 L6411B
FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 1
OF.WATF9 DENR—FRO State of North Carolina
Q Department of Environment and Natural Resources
co
r l .: U 12006 Division of Water Quality
o'er -mac �(� FAST -TRACK APPLICATION
cot�Q for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS
(Pressure sewers systems are not to be included as part of this application package)
INSTRUCTIONS: Indicate that you have included the following list of required application package items by checking the
space provided next to each item. Failure to submit all required items will lead to your application being returned as
incomplete or additional processing and review time. This form may be photocopied for use as an original.
® I. Application Form - Submit one original and one copy of the completed and appropriately executed application
form. Any changes to this form will result in the application being returned. The Division of Water Quality
(Division) will only accept application packages that have been fully completed with all applicable items
addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item 1302).
® II. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of
Environment and Natural Resources (NCDENR).
❑ III. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a
privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN)
which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the
sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities
Commission's Public Staff that states that an application for a franchise has been received, that the service area
is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the
CPCN or letter must match that provided in Item A(2a) of this application.
❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if
the sewer extension is permitted by a private applicant and will be serving residential or commercial lots (e.g.,
houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a
homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF
THE PROJECT WILL BE TURNED OVER TO A -MUNICIPALITY, FORM DEV 02/03 IS REQUIRED.
® V. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant,
submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different.
Flow acceptance letters must contain the following minimum information: applicant and project name, amount of
flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not
expire prior to permit issuance and must be dated less than a year prior to the application date.
Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance
letter.
® VI. Map — Submit an 8.5-inch by 11-inch COLOR copy of the portion of a 7.5-minute USGS Topographic Map along
with this form. The map should identify the entire project area location as well as the closest downslope surface
waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified
location of the sewer line and pump stations, and be of clear and reproducible quality. For instance, if the project
involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties,
basins, etc.), the map should have location ID's shown for each different waterbody (where the sewer line is within
100 feet of such waterbody - see Instruction VII). This location ID is self chosen and used to cross reference the
location in Section C of the permit application.
❑ VII. Stream Classifications — Section C
• If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed
for the pertinent sections.
• If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a
pump station involved where a history of power outage is to be used to provide adequate design storage
instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that
the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)).
• Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track
Sewer Systems)" available from http://h2o.enr.state.nc.us/ndpu or by contacting the appropriate regional
office.
FTA 02/03 - Rev. 2 04/04
FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2
IFA
❑ VIII. Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC
01C .05001, this application can not be used. Send the project application on Form PSFMGSA 10/99 to the
Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be
processed until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been
issued. A copy is to be submitted with that permit application.
® IX. Certifications — Section D
The application must be certified by both the applicant and a North Carolina Registered Professional Engineer
(PE). The applicant signature must match the signing official listed in Item A(lb). The PE should NOT certify the
application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most
recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains
(most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents
is subject to NC Board referral.
THE COMPLETED FTA 02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $400
FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE
REGIONAL OFFICE
ADDRESS
COUNTIES SERVED
Asheville Regional Office
Avery, Buncombe, Burke, Caldwell,
2090 US Highway 70
Cherokee, Clay, Graham, Haywood,
Swannanoa, North Carolina 28778
Henderson, Jackson, Macon,
(828) 296-4500
Madison, McDowell, Mitchell, Polk,
(828) 299-7043 Fax
Rutherford, Swain, Transylvania,
Yancey
Fayetteville Regional Office
225 Green Street Suite 714
Fayetteville, North Carolina 28301
Anson, Bladen, Cumberland, Harnett,
(910) 486-1541
Hoke, Montgomery, Moore, Robeson,
(910) 486-0707 Fax
Richmond, Sampson, Scotland
Mooresville Regional Office
919 N Main Street
Mooresville, North Carolina 28115
Alexander, Cabarrus, Catawba,
(704) 663-1699
Cleveland, Gaston, Iredell, Lincoln,
(704) 663-6040 Fax
Mecklenburg, Rowan, Stanly, Union
Raleigh Regional Office
1628 Mail Service Center
Chatham, Durham, Edgecombe,
Raleigh, North Carolina 27699-1628
Franklin, Granville, Halifax, Johnston,
Lee, Nash, Northampton, Orange,
(919) 571-47
(919) 571-4718 Fax
Person, Vance, Wake, Warren,
Wilson
Washington Regional Office
Beaufort, Bertie, Camden, Chowan,
943 Washington Square Mall
Craven, Currituck, Dare, Gates,
Washington, North Carolina 27889
Greene, Hertford, Hyde, Jones,
(252) 946-6481
Lenoir, Martin, Pamlico, Pasquotank,
(252) 975-3716 Fax
Perquimans, Pitt, Tyrrell, Washington,
Wayne
Wilmington Regional Office
127 Cardinal Drive Extension
Brunswick, Carteret, Columbus,
Wilmington, North Carolina 28405
Duplin, New Hanover, Onslow,
(910) 395-3900
Pender
(910) 350-2004 Fax
585 Waughtown Street
Alamance, Alleghany, Ashe, Caswell,
Winston-Salem Regional Office
Winston-Salem, North Carolina 27107
Davidson, Davie, Forsyth, Guilford,
(336) 7714600
Rockingham, Randolph, Stokes,
(336) 771-4631 Fax
Surry, Watauga, Wilkes, Yadkin
For more information, visit our web site at: http://h2o.enr.state.nc.us/ndpu/
FTA 02/03 - Rev. 2 04/04
FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3
(tppcation Number:
o be completed by DWQ) WQ002 9 911
1. Owner.
1 a. Town of Wadesboro
Full Legal Name (company, municipality, HOA, utility, etc.)
Z
1 b. Don McRorie, Mayor
O
Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!)
Q1
c. The legal entity who will own this system is:
❑ Individual ❑ Federal ® Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify):
Id. 107-A East Wade Street a. Wadesboro
QStreet
_1
Address City
Z
1f. North Carolina 1g. 28170
Z
State Zip Code
1 h. 704 694-5171 1 i. 1 j. wadesboromanager@alltel.net
QTelephone
Facsimile E-mail
V
2. Project (Facility) Information:
IL2a.
Wadesboro Hwy 74 Sewer Extension 2b. Anson
a
Brief Project Name (permit will refer to this name) County Where Project is Located
Q
3. Contact Person:
Q
3a. Bradley H. Bucy
Name and Affiliation of Someone Who Can Answer Questions About this Application
3b. 704-342-3000, (C) 704-512-9008 3c. bbucy@hobbsupchurch.com
Phone Number E-mail
1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.:
For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another
phase, changing line size/length, etc.). Only include the modified information in this permit application - do not
duplicate project information in B(7) and B(10-'L1 that has already been included in the original permit.
2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a))
2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one
❑ Retaining Ownership (i.e. store, church, single office, etc.) or, ❑ Public Utility (Instruction 111)
Z
❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV)
_0
❑ Selling units (lots, townhomes, etc. - go to Item B(2b))
H
Q
3. Anson County
Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project
O
4a. Anson County Regional Waste Water Treatment Plant 4b. NC 0041408
LL
Name of WWTF WWTF Permit No.
Z
5a. Wadesboro / Anson Coun
b. 12"
c.
Receiving Sewer Size
Permit Number of Downstream Sewer (if known)
Owner of Downstream Sewer
6. The origin of this wastewater is (check all that apply):
W®
Residential Subdivision ❑ Car Wash
a
[IApartments/Condominiums ❑ Institution 100 % Domestic/Commercial
❑ Mobile Home Park ❑ Hospital
❑ School ❑ Church % Industrial
❑ Restaurant ❑ Nursing Home fY)
Office ® Other (specify): eci Commercial Retail �o
® � o Other (specify):
7. Volume of wastewater to be permitted in this project: 0 gallons per day
8. If the permitted flow is zero, indicate why:
❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line
® Flow has already been allocated in Permit No. W000029577
❑ Rehabilitation or replacement of existing sewer with no new flow expected
FTA 02/03 - Rev. 2 04/04
FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4
9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H
.0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than
that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to
the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in
accordance with 15A NCAC 2H .0219(l)(3).
10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary)
Size (inches) Length (feet) Gravity or Force Main
(use the pull down menu)
10 3,350 Gravity
8 3,170 Gravity
LU
U
O ENTER TOTAL LINE LENGTH IN MILES \/ 1.23
Q11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary)
Location ID Power Reliability Option
(self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3-
0 plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage)
LL
Z N/A
F-
W
12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force
m Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?
® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a
variance is requested:
SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
13. Have the following permits/certifications been submitted for approval?
Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A
Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A
Stormwater?
® Yes ❑ No ❑ N/A
FTA 02/03 - Rev. 2 04/04
FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5
O
H
a
U
M
U)
U)
g
c.)
�W
1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03
(FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as
necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality
regional office (see instructions for addresses) OR indicate the following:
® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope
' waterbody; AND,
® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability
option for any pump station near a Class C down slope waterbody.
Location ID on Map
(self chosen - as shown on Name of Waterbody Stream ; Waterbody
map for cross-reference) Waterbody County ` River Basin Index Classification
i
Submit the 8.5" x 11" COLOR topographic map as required In Instruction A
regardless of whether a classification is providedl
. Applicant's Certification:
1, Don McRorie, attest that this application for Wadesboro Hwy 74 Sewer Extension, has been reviewed by me and is
accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not
completed and that if all required supporting documentation and attachments are not included, this application package
is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and
143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application
shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to
_ $25,000 per violation. - -- — --- -- - -- -----
1a. 102 / 09 0
Signing Official Signature Don McRorie - M Date
2. Professional Engineers Certification:
I attest that this application for Wadesboro Hwy 74 Sewer Extension has been reviewed by me and is accurate, complete)'
and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the
best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in
accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February
12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June
1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal
package may have been developed by other professionals, inclusion of these materials under my signature and seal
signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In
accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,
representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to
i
exceed $10,000 as well as civil penalties up to $25,000 per violation.
2a. Bradley H. Bucy, P.E. .•```
P-1H CARo
Professional Engineer Name p li
2b. Hobbs, Upchurch & Associates, P.A.
Engineering Firm -
N No. G' ruy
2c. 1300 Baxter Street, Suite 108 a m
' Address a
2d. Charlotte 2e. NC 2f. 28204
J
City State Zip
�'�•,�� ��.``� EY H
2g. 704-342-3000 2h. 704-342-3077 2i bbucy@hobbsupchurch.com
Telephone Facsimile E-mail Seal, Signature &Date
FTA 02/03 - Rev. 2 04/04
A
...........
11
7
IN
�71
3,
N
Ij.
Wi
0 ,
300
16
423
t
D64
L
r
J
f
POA
*a
3aO
'5
330
\41 5
\0
In
f
4�-
( /
K: 31
;ti , p,
! �'r •Aih
I
v
+
IX
8'W
Name: WADESBORO Location: 034* 58'44.3" N 080' 06'42.9" W
Date: 2/6/2006
Scale: 1 inch equals 2000 feet
t:nnvnnnT iC.i imm/ manTp.r.ri inc