HomeMy WebLinkAboutWQCSD0453_Regional Office Physical File Scan Up To 12/23/2020I L
A=&j*
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Resources
Water Quality Programs
Pat McCrory Thomas A. Reeder John E. Skvarla, III
Governor Acting Director Secretary
August 13, 2013
Freddie Boan
Trillium Links & Village LLC
One Trillium Ctr
Cashiers NC 28717
SUBJECT: Collection System Inspection
Trillium Links & Village WWTP
Permit No: WQCSD0453
Jackson County
Dear Mr. Boan:
Enclosed please find a copy of the collection system inspection conducted on Jul
24, 2013. No violations of permit requirements or applicable regulations were observed
during this inspection.
Please refer to the enclosed inspection report for additional observations and
comments. If you or your staff have any questions, please,411 me at 828-296-4500.
Sincerely,
Jeff Menzel
Environmental Specialist
Enclosure
cc: Central Files
-Ashe�ille�F9les
SURFACE WATER PROTECTION — ASHEVILLE REGIONAL OFFICE
Location: 2090 U.S. Highway 70, Swannanoa, NC 28778 NorthCarolina
Phone: (828) 296-45001FAX: 828 299-7043 Internet: www.ncwatercivality.ora �gAltg L`//ff
G:\WQ\SWP\Jackson\Collection Systems\Trillium Link and Village\WQCSD0453 CEI 2013.doc
I ;I
Compliance Inspection Report
Permit: WQCSD0453 Effective: 07/29/09 Expiration: Owner: Trillium Links & Village LLC
SOC: Effective: Expiration: Facility: Trillium Links & Village WWTP
County: Jackson NCSR 1145
Region: Asheville
Cashiers NC 28717
Contact Person: Freddie Boan Title: Phone: 828-743-6161
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Certification: Phone:
Inspection Date: 07/24/2013 Entry Time: 10:30 AM Exit Time: 12:00 PM
Primary Inspector: Jeff Menzel ::::jX ���?% Phone: 828-296-4500
Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling
Permit Inspection Type: Deemed permitted collection system management and
operation
Facility Status: ■ Compliant ❑ Not Compliant
Question Areas:
Miscellaneous Questions Operation & Maint Reqmts 0 Inspections Pump Station
Lines
(See attachment summary)
Page: 1
Permit: WQCSD0453 Owner - Facility: Trillium Links & Village LLC
Inspection Date: 07/24/2013 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine
Inspection Summary:
There are approximately 100 to 125 homes connected to the collection system. There are five lift stations without
telemetry. Daily visits of the pump stations are made by staff 7 days a week. Three of the pump stations were observed
during this inspection with no issues noted. No violations of permit requirements or applicable regulations were observed
during this inspection.
Page: 2
Permit: WQCSD0453 Owner - Facility: Trillium Links & Village LLC
Inspection Date: W/24/2013 Inspection Type: Collection System Inspect Non Sampling
Reason for Visit:
Routine
Inspections
Yes
No
NA
NE
Are maintenance records for sewer lines available?
■
n
n
n
Are records available that document pump station inspections?
■
n
n
n
Are SCADA or telemetry equipped pump stations inspected at least once a week?
n
n
■
n
Are non-SCADA/telemetry equipped pump stations inspected every day?
■
In
n
n
Are records available that document citizen complaints?
n
n
n
■
# Do you have a system to conduct an annual observation of entire system?
■
n
❑
n
# Has there been an observation of remote areas in the last year?
■
n
n
n
Are records available that document inspections of high -priority lines?
■
n
n
n
Has there been visual inspections of high -priority lines in last six months?
■
n.
n
n
Comment:
Operation & Maintenance Requirements
Yes
No
NA
NE
Are all log books available?
■
❑
n
n
Does supervisor review all log books on a regular basis?
■
n
n
n
Does the supervisor have plans to address documented short-term problem areas?
■
n
n
n
What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas?
weekly/monthly
Are maintenance records for equipment available?
■
❑
❑
n
Is a schedule maintained for testing emergency/standby equipment?
■
n
n
-What is the schedule for testing emergency/standby equipment?
weekly/monthly
Do pump station logs include:
Inside and outside cleaning and debris removal?
■
n
n
n
Inspecting and exercising all valves?
■
❑
n
n
Inspecting and lubricating pumps and other equipment?
■
n
n
n
Inspecting alarms, telemetry and auxiliary equipment?
■
n
n
n
Is there at least one spare pump for each pump station w/o pump reliability?
■
n
n
n
Are maintenance records for right-of-ways available?
n
n
n
■
Are right-of-ways currently accessible in the event of an emergency?
■
Cl
n
n
Are system cleaning records available?
n
❑
❑
■
Has at least 10% of system been cleaned annually?
nnn■
Page: 3
Permit: WQCSD0453 Owner - Facility: Trillium Links & Village LLC
Inspection Date: 07/24/2013 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine
What areas are scheduled for cleaning in the next 12 months?
Is a Spill Response Action Plan available?
■
fl Cl 0
Does the plan include:
24-hour contact numbers
■
n n p
Response time
■
❑ ❑ ❑ '.
Equipment list and spare parts inventory
` ■
n n n
Access to cleaning equipment
■
n . n
Access to construction crews, contractors, and/or engineers
■
❑ n n
Source of emergency funds
■
Site sanitation and cleanup materials
■
❑ 0 0
Post-overflow/spill assessment
■
Q Q El
Is a Spill Response Action Plan available for all personnel?
■
n n n
Is the spare parts inventory adequate?
■
fl
Comment:
Page: 4
Central Files: APS SWP
09/01 /09
Permit Number WQCSD0453
Permit Tracking Slip
Program Category
Status Project Type
Non -discharge
Active New Project
Permit Type
Version Permit Classification
Deemed permitted collection system management and operation
1.00 Individual
Primary Reviewer
Permit Contact Affiliation
wanda.frazier
Coastal SW Rule
Permitted Flow
Facility
Facility Name
Major/Minor Region
Trillium Links & Village LLC
Minor Asheville
Location Address
County
NCSR 1145
Jackson
Cashiers NC 28717
Facility Contact Affiliation
Owner
Owner Name
Owner Type
Trillium Links & Village LLC
Non -Government
Owner Affiliation
Gregory A. Ward
PO Box 2644
Cashiers NC 28717
Dates/Events
Scheduled
Orig Issue App Received Draft Initiated Issuance
Public Notice Issue Effective Expiration
07/29/09 07/29/09
07/29/09 07/29/09
Regulated Activities
Condominium
Subdivision
Outfall NULL
Waterbody Name
Stream Index Number Current Class Subbasin
I
2009
System Performance Annual Report
Wastewater Treatment Facility FFF
General Information
Facility/System Name: Trillium Links & Village, LLC
Responsible Entity: Trillium Links & Village, LLC
YILII� FBI
MAR 042010
Person in Charge: Freddie-Boan General Manager of Community Associations
Telephone Number: (828) 743-6161
Contract Operator in Responsible Charge: RPB Systems, Inc -Robert Barr
Telephone Number: (828) 251-1900
• Applicable Permit:_NPDES NC0059200z-.Expi es:10/31/2012
• Description of Tr trri-nfSystem TT "
The Trillium Links & Village wastewater treatment system is a 0.04 MGD
extended aeration package wastewater treatment plant with flow equalization,
tertiary filters, chlorination` and dechlorination equipment and standby power. This
facility is located at the Trillium Links & Village near Glenville off of Finlay Forest
Trail in Jackson County, NC. The treated effluent discharges into an unnamed
tributary to Hurricane Creek (Thorpe Lake), a class WS-III Trout HQW stream in
the subbasin 04-04-02 of the Little -Tennessee River Basin.
Performance
• Summary of System Performance for 2009:
This facility is well maintained and in good operational condition. Records are
being maintained as required by their NPDES permit.
The treatment facility experienced no overflows or spills in 2009.
Page 1 of 3
• 2009 Monthly Compliance Summary
• January 2009-Compliant
• February 2009-Compliant
• March 2009-Compliant
• April 2009-Compliant
• May 2009-Compliant
• June 2009-Compliant
• July 2009- Compliant
• August 2009-Compliant
• September 2009-Compliant
• October 2009-Compliant
• November 2009-Compliant
• December 2009-Compliant
• Listed below are the, monthly Discharge Monitoring Report parameters as
reported to the Division of Water Quality in 2009.
Flow
BOD
TSS
NH3N
Fecal
Jan
0.0094
6.8
8.9
0.10
2.0
Feb
0.0030
4.3
5.7
0.12
2.0
Mar
0.0039
3.0
4.7
0.10
2.0
April
0-0060
2.4
6.8
0.10
2.0
May
0.0096
2.2
3.3
0.10
3.0
June
0.0102
2.1
5.3
0.17
3.0
July
0.0236
2.9
6.0
0.53
2.0
Aug0.0158
3.2
5.3
0.10
2.0
Set
0.0118
3.1
5.6
0.10
2.0
Oct
0.0092
4.3
7.0
1.00
2.0
Nov
0.0083
2.5
7.0
0.10
2.0
Dec
0.0047
3.7
7.7
0.10
6.7
5.0/7.5
3.0/15.0
mg/I
mg/I
Summer
Summer
10.0/15.0
6.0/30.0
200/400
Permit
0.04
mg/i
20/30
mg/I
col/100
Limits
MGD
Winter
m /I
Winter
ml
Page 2 of 3
Corrective Actions: No corrective actions were required during 2009.
All parameters were within permit limitations.
• Environmental Impact: There has been no observable environmental impact at
this facility.
III. Notification
Clients will be sent a copy of the report by mail.
IV. Certification
I certify under penalty of law that this report is accurate and complete to the best
of my knowledge. I further certify that this report has been made available to the
users or customers of this system and that those users have been notified of its
availability. I am aware that there are significant penalties for submitting false
information.
Z Z ifAC)
Signature Date
Freddie Boan
General Manager of Community Associations
Page 3 of 3
Michael F. Easley, Governor
William G. Ross Jr., Secretary
FLrthrgolirla Department of Environment and Natural Resources
...w.. Rri�1i :`�S-:Y.:;SL--� .+_Je:J`=ati •S .:J
Coleen H. Sullins, Director
Division of Water Quality
SURFACE WATER PROTECTION SECTION
September 6, 2007
Mr. Ward
Trillium Links & Village LLC
PO Box 2644
Cashiers, NC 28717
SUBJECT: Wastewater Collection System
Owner & Operator Requirements
Trillium Links & Village LLC
NCO059200
Jackson County
Dear Mr: Ward:
I would like to take this opportunity to discuss the .requirements for sewerage collection
systems that were first established in 15 NCAC .02H .0200 in March 2000 and are now found in
15 NCAC 2T .0403, Waste Not Discharged to Surface Watersl which became effective
September 1, 2006. These Regulations place significant operation, maintenance and reporting
requirements on those entities that own or operate a wastewater collection system with average
daily flows of less than 200,000 gallons per day.
These regulations are applicable to your facility. This letter is provided as guidance
to assist you in complying with the new reporting and operations and maintenance (O&M)
requirements and to advise you that you are subject to system review, inspections and possible
enforcement, if the system is not in compliance with the regulation.
For your convenience and easy reference, a highlight of these requirements and the
following guidance are offered (see enclosed). You may find the regulations using the following
web site: http://h2o.enr.state.nc.us/peres/Collection%20Systems/CollectionSystemsHome.htmI
The Asheville Regional Office will be increasing the level of oversight, compliance
activities and enforcement relating to collections systems, therefore, we wanted to be sure you
are aware of the requirements for these systems. We will be performing NPDES Wastewater
Collection System inspections) sometime in the near future.
NorthCarolina
Naturally
North Carolina Division of Water Quality 2090 US Hwy 70; Swannanoa, NC 28778 Phone (828) 296-4500
Internet: www..ncwaterquality.org Customer Service 1-877-623-6748 FAX (828) 299-7043
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
September 6, 2007
Page 2 of 2
i
If this Office has not previously inspected your wastewater collection system and records
of same, you should be prepared to demonstrate compliance with all criteria listed above.
Enclosed is an inspection form that you can use to assemble your records prior to an inspection
by the staff of this Office.
This Office has a Wastewater Treatment Plant Consultant on staff to offer assistance to
you in complying with the requirements of these regulations. Should you have questions or
-need -add itional-information-regardinzd-this ssuc,-please contact Don Price atl82S)-296-4500.
Should you have any other questions concerning this correspondence or the
requirements relating to collection systems, please contact Roy Davis or Keith Haynes at 828-
296-4500.
Sincerely,
Roger C. Edwards, Supervisor
Surface Water Protection Section
cc: Deborah Gore - PERCS Unit - w/out enclosures
Asheville-Reg ion al-Office-fac_iIity`file �w/out=enclosures_w__Y
DVV- - SWPS - Central Office Files - w/out enclosures
C