Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW4201201_(2020.12.10) - Coldwater CD Set_20201221
© 2019 Microsoft Corporation © 2019 HERE SITE C0.0 COVER SHEETM. MARTIN M. MARTIN R. RINGLER AS SHOWN Sheet Index Sheet Number Sheet Title C0.0 COVER SHEET C1.0 OVERALL EXISTING CONDITIONS COLDWATER VICINITY MAP 1" = 2,000' OWNER/DEVELOPER CONSTRUCTION DRAWINGS 8228 COLDWATER ROAD, STOKESDALE, NC 27357 AT LEAST 72 HOURS PRIOR TO CONSTRUCTION OR EXCAVATION THE CONTRACTOR SHALL NOTIFY "NORTH CAROLINA ONE CALL" (811) OR (1-800-632-4949) TO HAVE EXISTING UTILITIES LOCATED. ALL LOCAL UTILITY PROVIDERS USING THEIR OWN LOCATING SERVICE SHALL BE CONTACTED BY THE CONTRACTOR. CIVIL ENGINEER TIMMONS GROUP 8642 W. MARKET STREET, SUITE 136 GREENSBORO, NC 27409 PROJECT MANAGER: RICK RINGLER, PE PHONE: (336) 478-3353 EMAIL: RICK.RINGLER@TIMMONS.COM FIRST CAROLINA HOMES 5411 TORY HILL DR., GREENSBORO, NC 27410 CONTACT: PAUL HOLST PHONE: (336) 944-7919 EMAIL:PAUL@1STCAROLINAHOMES.COM C1.1 - C1.2 PHASE I EROSION CONTROL PLAN C1.3 - C1.4 PHASE II EROSION CONTROL PLAN C2.0 OVERALL SUBDIVISION PLAN C2.1 SUBDIVISION PLAN - NW C2.2 SUBDIVISION PLAN - NE C3.0 OVERALL GRADING AND DRAINAGE PLAN C3.1 GRADING AND DRAINAGE PLAN - NW C3.2 GRADING AND DRAINAGE PLAN - EAST C4.0 OVERALL UTILITY PLAN C4.1 UTILITY PLAN - NW C4.2 UTILITY PLAN - NE C5.0 - C5.2 OFF-SITE WATER MAIN PLAN/ PROFILE C6.0 - C6.2 COLD WATER TERRACE PLAN & PROFILE C6.3 - C6.5 BOATHOUSE WAY PLAN & PROFILE C7.0 - C7.4 NOTES AND DETAILS AUGUST 21, 2020 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C0.0 - COVR.dwg | Plotted on 12/10/2020 1:30 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTS1.TYPE OF SUBMITTAL:CONSTRUCTION DOCUMENTS 2.DEVELOPMENT:COLDWATER (PROJECT ID: 349867) 3.PIN #:6690-35-6657 (FORSYTH), 6990-45-8600 (GUILFORD) 4.ADDRESS:8228 COLDWATER ROAD, STOKESDALE, NC 27357 5.CURRENT ZONING:RS-40S (FORSYTH), AG (GUILFORD) 6.ADJACENT ZONING:AG, RS-40S 7.PROPOSED ZONING: RS-40S (FORSYTH), AG (GUILFORD) 8.PROPOSED USE:RESIDENTIAL BUILDING SINGLE-FAMILY 9.ADJACENT USE:RESIDENTIAL SINGLE-FAMILY, VACANT 10.DEED BOOK REFERENCE:DB 7787 - PG 2290 (GUILFORD), DB 3273 - PG 1847 (FORSYTH) 11.PROJECT LOT AREA:11.89 AC (GUILFORD), 66.39 AC (FORSYTH) ; 78.279 AC TOTAL 12.TOTAL # OF LOTS:56 SINGLE-FAMILY (2 REMOTE SEPTIC) 13.DENSITY:56 UNITS / 78.279 AC = 0.72 UNITS/AC 14.COORDINATES:36.23, -80.04 15.RIVER BASIN:ROANOKE RIVER BASIN 16.SOIL TYPES:FaC, Gu, PpC2, PpD2, FeE2, FaD, DaA 17.WATERSHED:DAN RIVER (UNPROTECTED) 18.LINEAR FOOTAGE OF STREET:6,702 LF (PUBLIC) 19.BUILT UPON AREA:11.24 AC (14.35%) 20.PARKING REQUIRED:1 SPACE PER 125 SF OF POOL AREA (FUTURE POOL) 1 SPACE PER 25 LOTS (FOR CLUSTER BOX UNIT) = (1,000 SF (POOL)/ 125 SF) + (56 LOTS/ 25 LOTS) = 8 SPACES + 3 SPACES = 11 PARKING SPACES REQUIRED 21.PARKING PROVIDED:11 SPACES (1 ADA/ VAN ACCESSIBLE SPACE) 22.LIMITS OF DISTURBANCE:23.82 AC (FORSYTH), 6.10 AC (GUILFORD); 29.92 AC (TOTAL) SITE DATA C6.6 ROAD PLAN & PROFILE C2.3 SUBDIVISION PLAN - SW C2.4 SUBDIVISION PLAN - SE C2.5 SUBDIVISION PLAN - EAST C3.5 GRADING AND DRAINAGE PLAN - NE C3.3 GRADING AND DRAINAGE PLAN - SW C3.4 GRADING AND DRAINAGE PLAN - SE C4.3 UTILITY PLAN - SW C4.4 UTILITY PLAN - SE C4.5 UTILITY PLAN - EAST REVISED OCTOBER 09, 2020 REVISED OCTOBER 23, 2020 C3.6 POST-DEVELOPMENT DRAINAGE MAP REVISED DECEMBER 1, 2020 REVISED DECEMBER 10, 2020 DEED LINE60'R/WR/WOHPOHPOHPDAVID W. HOWELL D.B. 7848 - PG. 272 LOT 6 P.B. 196 - PG. 129 BILLY R. MOORE D.B. 7305 - PG. 2125 DUKE POWER CO. D.B. 2495 - PG. 509 ROBERT N. OGLESBY D.B. 3524 - PG. 1476 ( P.B. 103 - PG. 98 ) DEED LINE D.B. 7305 - PG. 2125 OWNERSHIP UNKNOWN (±1.3 ACRES) ( FIRST TRACT ) ( FIRST TRACT )XPOTENTIALLY JURISDICTIONAL WETLAND JURISDICTIONAL TRIBUTARIES POTENTIALLY JURISDICTIONAL TRIBUTARY COLDWATER ROADS 87°40'37" W ( 294.01' ) S 87°40'37" W 1483.80'S 00°22'16" W113.21'263.96' N 56° 1 0' 5 9 " E 199.9 6' NIP 241.95'129.37'248.07'349.82' N 88°33'53" E ( 1027.80' ) 26.72' 31.87' S 87°40'37" W 340.74' ( 400.84' )S 01°23'25" W339.60'N 89°37'18" W ( 441.61' ) EIP 165.75'275.86' N 88°33'53" E 31.87' CENTER OF ABANDONED RAILROAD BED ± 21.276 ACRES CONCRETE MONUMENT RAILROAD BED CENTER OF ABANDONED FORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTYELLIPTICAL CMP 9.5'x6' INV.: 744.27' ELLIPTICAL CMP 9.5'x6' INV.: 743.95' 18"CMP INV.: 742.89' 18"CMP INV.: 742.40' 15"RCP INV.: 737.78' ELLIPTICAL CMP 11.5'x7' INV.: 728.41' ELLIPTICAL CMP 11.5'x7' INV.: 728.34' 18"CMP INV.: 743.15'18"CMP INV.: 742.00' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 PIN: 6990-54-1459-000 N/F: DUKE POWER COMPANY DB 2495 PG 509 ZONING: PIN: 6990-45-8600-000 N/F: STUART WAYNE PARRISH AND GEORGE WINFIELD PARRISH AS CO-TRUSTEES OF THE ANDREW QUENTIN PARRISH SPECIAL NEEDS TRUST U/A OF LOUISE FULTON PARRISH: DB 7787 PG 2290 PB 200 PG 146 ZONING: AG PIN: 6990-34-9796 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-15-7869.00 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: PIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 PIN: 6990-35-6657 N/F: EDGAR G. PARRISH: DB 1119 PG 1049 PB 70 PG 42 ZONING: RS-40S PIN: 6990-35-6657 N/F: STUART WAYNE PARRISH AND GEORGE WINFIELD PARRISH AS CO-TRUSTEES OF THE ANDREW QUENTIN PARRISH SPECIAL NEEDS TRUST U/A OF LOUISE FULTON PARRISH DB 3273 PG 1847 (PART OF LOTS 44 AND 45 OF PB 12 PG 76) PB 70 PG 42 ZONING: RS-40S REIDSVILLE ROAD (US H I G H W A Y 1 5 8 )COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PE/P E/PE/P E/P BARBED WIRE FENCE ENCROACHES BARBED WIRE FENCE ENCROACHES 20' UTILITY EASEMENTBARBED WIRE FENCE JURISDICTIONAL WETLAND HA4 HA3 HA2 HA1 B14 B13 B-10 B9 B8B7 B6 B11 B12 B5B4 B1 B2 B3 760 765 770 775 780 785 790 795 775780785790785 780 795790 800 800802 795 790 785 790795800805810 810812 8 0 5 810815820825 8258 2 5820815810805800795790785780775 770 770775 780 785 790795 800805810 805 800 79 5 803 830831830831830829 828 827 82 5 82 0 81 5 810 80 5 800 795 790 7 9 5 8008058 1 0815 820825830832825820815805800800 800 797 795790785780777 776 775 77 4 772775780785786790795800805 810 80 5 810 812 814 815 810 805 765760 760765770768765761 7657707 7 0 7 6 5 7647657707717707687 6 5 7 6 0 76 2 775770 7 7 5 77677 0 7 7 5 7 7 4 77375576076577076575575375575375 2 7507467 4 8 768765 760 766767755750 745 740 735 73573774 0 734 728 739740735735745740750740745752745750750745747745748747742745748747740740741754748751743738 760755754775780 7857807 7 0 76 9 7 7 5 795775775770765775 780 785 770BENT 1/2"IPF 1/2"IPF CMNF CMNF S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'N88°30'30"E 380.47' OHP OHPOHPOHPOHPOHP750750750750 77077077030' STREAM BUFFER 20" TREE 28" TREE 100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) 7 5 0 7 7 0 750 TREE EDGE (TYP) (5) UNKNOWN SIZE TREES 24" SYCAMORE DEED LINE60'R/WR/WOHPOHPOHPDAVID W. HOWELL D.B. 7848 - PG. 272 LOT 6 P.B. 196 - PG. 129 BILLY R. MOORE D.B. 7305 - PG. 2125 DUKE POWER CO. D.B. 2495 - PG. 509 ROBERT N. OGLESBY D.B. 3524 - PG. 1476 ( P.B. 103 - PG. 98 ) DEED LINE D.B. 7305 - PG. 2125 OWNERSHIP UNKNOWN (±1.3 ACRES) ( FIRST TRACT ) ( FIRST TRACT )XPOTENTIALLY JURISDICTIONAL WETLAND JURISDICTIONAL TRIBUTARIES POTENTIALLY JURISDICTIONAL TRIBUTARY COLDWATER ROADS 87°40'37" W ( 294.01' ) S 87°40'37" W 1483.80'S 00°22'16" W113.21'263.96' N 56° 1 0' 5 9 " E 199.9 6' NIP 241.95'129.37'248.07'349.82' N 88°33'53" E ( 1027.80' ) 26.72' 31.87' S 87°40'37" W 340.74' ( 400.84' )S 01°23'25" W339.60'N 89°37'18" W ( 441.61' ) EIP 165.75'275.86' N 88°33'53" E 31.87' CENTER OF ABANDONED RAILROAD BED ± 21.276 ACRES CONCRETE MONUMENT RAILROAD BED CENTER OF ABANDONED FORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTYELLIPTICAL CMP 9.5'x6' INV.: 744.27' ELLIPTICAL CMP 9.5'x6' INV.: 743.95' 18"CMP INV.: 742.89' 18"CMP INV.: 742.40' 15"RCP INV.: 737.78' ELLIPTICAL CMP 11.5'x7' INV.: 728.41' ELLIPTICAL CMP 11.5'x7' INV.: 728.34' 18"CMP INV.: 743.15'18"CMP INV.: 742.00' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 PIN: 6990-54-1459-000 N/F: DUKE POWER COMPANY DB 2495 PG 509 ZONING: PIN: 6990-45-8600-000 N/F: STUART WAYNE PARRISH AND GEORGE WINFIELD PARRISH AS CO-TRUSTEES OF THE ANDREW QUENTIN PARRISH SPECIAL NEEDS TRUST U/A OF LOUISE FULTON PARRISH: DB 7787 PG 2290 PB 200 PG 146 ZONING: AG PIN: 6990-34-9796 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-15-7869.00 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: PIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 PIN: 6990-35-6657 N/F: EDGAR G. PARRISH: DB 1119 PG 1049 PB 70 PG 42 ZONING: RS-40S PIN: 6990-35-6657 N/F: STUART WAYNE PARRISH AND GEORGE WINFIELD PARRISH AS CO-TRUSTEES OF THE ANDREW QUENTIN PARRISH SPECIAL NEEDS TRUST U/A OF LOUISE FULTON PARRISH DB 3273 PG 1847 (PART OF LOTS 44 AND 45 OF PB 12 PG 76) PB 70 PG 42 ZONING: RS-40S REIDSVILLE ROAD (US H I G H W A Y 1 5 8 )COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PE/P E/PE/P E/P BARBED WIRE FENCE ENCROACHES BARBED WIRE FENCE ENCROACHES 20' UTILITY EASEMENTBARBED WIRE FENCE JURISDICTIONAL WETLAND HA4 HA3 HA2 HA1 B14 B13 B-10 B9 B8B7 B6 B11 B12 B5B4 B1 B2 B3 760 765 770 775 780 785 790 795 775780785790785 780 795790 800 800802 795 790 785 790795800805810 810812 8 0 5 810815820825 8258 2 5820815810805800795790785780775 770 770775 780 785 790795 800805810 805 800 79 5 803 830831830831830829 828 827 82 5 82 0 81 5 810 80 5 800 795 790 7 9 5 8008058 1 0815 820825830832825820815805800800 800 797 795790785780777 776 775 77 4 772775780785786790795800805 810 80 5 810 812 814 815 810 805 765760 760765770768765761 7657707 7 0 7 6 5 7647657707717707687 6 5 7 6 0 76 2 775770 7 7 5 77677 0 7 7 5 7 7 4 77375576076577076575575375575375 2 7507467 4 8 768765 760 766767755750 745 740 735 73573774 0 734 728 739740735735745740750740745752745750750745747745748747742745748747740740741754748751743738 760755754775780 7857807 7 0 76 9 7 7 5 795775775770765775 780 785 770BENT 1/2"IPF 1/2"IPF CMNF CMNF S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'N88°30'30"E 380.47' OHP OHPOHPOHPOHPOHP750750750750 77077077030' STREAM BUFFER 20" TREE 28" TREE 100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) 7 5 0 7 7 0 750 TREE EDGE (TYP) (5) UNKNOWN SIZE TREES 24" SYCAMORE 24"SYCAMORE24"SYCAMORE C1.0 OVERALL EXISTING CONDITIONSM. MARTIN M. MARTIN R. RINGLER 1" = 150' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C1.0 - EXIST.dwg | Plotted on 12/10/2020 1:30 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTS0 300' SCALE 1"=150' 150'NAD 83VICINITY MAP 1" = 2000'NAD 83BOUNDARY SURVEY PROVIDED BY VAUGHN SURVEYING CO., INC. DATED MARCH 25, 2019. EXISTING CONDITIONS LEGEND X X OHP W OHT SAN UGP G (T) - INDICATES POINTS SET BY TIMMONS GROUP - CALCULATED POINT UNLESS OTHERWISE NOTED SPRINKLER VALVE HVAC - HEATING, VENTILATION AND AIR CONDITIONING GAS VALVE FENCE EDGE OF WOODS PAINTED WATER LINE PAINTED TELEPHONE LINE GUY CABLE TV PEDESTAL CM - CONCRETE MONUMENT IPS - IRON PIPE SET IRF - IRON ROD FOUND IPF - IRON PIPE FOUND PT - CALCULATED POINT TELEPHONE PEDESTAL FIRE HYDRANT LIGHT POLE POWER POLE ELECTRIC BOX PG - PAGE SF - SQUARE FEET YI - YARD INLET GI - GRATE INLET CB - CATCH BASIN NTS - NOT TO SCALE R / W - RIGHT-OF-WAY C / L - CENTERLINE P / L - PROPERTY LINE CI - CURB INLET PB - PLAT BOOK DB - DEED BOOK EP - EDGE OF PAVING HDPE - HIGH DENSITY POLYETHYLENE PIPE SPRINKLER HEAD SIGN TBC - TOP BACK OF CURB FLAG POLE BRICK GROUND LAMP CONCRETE STORM LINE SANITARY LINE OVERHEAD POWER LINE VCP - VITRIFIED CLAY PIPE C A - CONTROLLED ACCESS MH TELEPHONE MH SANITARY SEWER MH STORM SEWER BOLLARD SPRINKLER BOX WATER VALVE GAS METER CLEAN OUT WATER METER ELECTRIC METER WELL MH WATER YARD LIGHT S W D E T C T W MH ELECTRIC PAINTED POWER LINE PAINTED GAS LINE ROOF DRAIN MH GREASEG MAILBOX TRAFFIC SIGNAL POLE IN 2009 CMP - CORRUGATED METAL PIPE CPP - CORRUGATED PLASTIC PIPE RCP - REINFORCED CONCRETE PIPE DIP - DUCTILE IRON PIPE BORING LOCATION FLOODPLAIN POTENTIALLY JURISDICTIONAL TRIBUTARY N 56° 1 0' 5 9 " E 199.9 6' PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: JURISDICTIONAL WETLAND 760 765 770 775 780 785 790 795 775780785790785 780 795 790 800 800802 795 790 785 790795800805810 810812 8 0 5 810815820825 8258 2 5820815810805800795790785 780775 770 770775 780 785 790795 800805810 805 800 79 5 803 830831830831830829 828 827 82 5 8 2 0 81 5 810 80 5 800 795 790 7 9 5 800805810815820825830832825820815805775780785 7807 7 0 76 9 7 7 5 795775775770765775 780 785 S76°1 3 ' 5 6 " E 2,215. 4 0 '750750750750 7707707707 7 0 CLEAR AND GRUB CLEAR AND GRUB CLEAR AND GRUB CLEAR AND GRUB 25' EMERGENCY SPILLWAY EL: 749.00 2'X2' ENERGY DISSIPATOR SILT FENCE (TYP) TEMPORARY DIVERSION DITCH (TYP) POROUS BAFFLE (TYP) 2.5" SKIMMER W/ 1.75" ORIFICE DRAINAGE AREA (TYP) SILT FENCE (TYP) SILT FENCE (TYP) SILT FENCE (TYP) TEMPORARY DIVERSION DITCH (TYP) TEMPORARY DIVERSION DITCH (TYP) TEMPORARY DIVERSION DITCH (TYP) SLOPE DRAIN (TYP) DRAINAGE AREA (TYP) STONE OUTLET (TYP) 20' EMERGENCY SPILLWAY EL: 757.00 2'X2' ENERGY DISSIPATOR 2" SKIMMER W/ 1.25" ORIFICE POROUS BAFFLE (TYP) SILT FENCE (TYP) TEMPORARY DIVERSION DITCH (TYP) LIMITS OF DISTURBANCE SKIMMER BASIN #1 PHASE 1 DRAINAGE AREA = 8.16 AC PHASE 1 Q10 = 23.51 CFS SKIMMER BASIN #2 PHASE 1 DRAINAGE AREA = 6.09 AC PHASE 1 Q10 = 16.63 CFS 0.69 AC 1.21 AC SURFACE ROUGHENING (TYP) SURFACE ROUGHENING (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) SLOPE DRAIN (TYP) SLOPE DRAIN (TYP) LIMITS OF DISTURBANCE 0.16 AC 0.18 AC MAINTAIN POSITIVE DRAINAGE (TYP) MAINTAIN POSITIVE DRAINAGE (TYP)S 00°22'16" W113.21'7807 7 0 76 9 7 7 5 7 5 0 7 7 0 750 SILT FENCE (TYP) STONE OUTLET (TYP) STOCKPILE AREA (±51,050 SF)SILT FENCE (TYP) SKIMMER BASIN #6 PHASE 1 DRAINAGE AREA = 3.16 AC PHASE 1 Q10 = 8.63 CFS 15' EMERGENCY SPILLWAY EL: 747.00 2'X2' ENERGY DISSIPATOR 1.5" SKIMMER W/ 1.25" ORIFICEPOROUS BAFFLE (TYP) SLOPE DRAIN (TYP) C1.1 PHASE I EROSION CONTROL PLANM. MARTIN M. MARTIN R. RINGLER 1" = 60' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C1.1 - EROS.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSS:\107\44636-Coldwater\DWG\Sheet\CD\C1.1 - EROS.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin0 SCALE 1"=60' 120'60'NAD 83MATCHLINESHEET C1.2EROSION CONTROL NOTES 1.DO NOT WORK OR DISTURB LAND OUTSIDE LIMITS OF CONSTRUCTION. 2.ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL COMPLY WITH NCDEQ STANDARDS, SPECIFICATIONS, AND DETAILS. 3.INSPECT EROSION AND SEDIMENT CONTROL MEASURES WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. MAINTAIN MEASURES AS NECESSARY. 4.GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS BUT NO MORE THAN 21 CALENDAR DAYS AFTER COMPLETION OF ANY PHASE OF GRADING. PERMANENT GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS OR NO MORE THAN 21 CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION. 6. KEEP MUD OFF STREETS DURING CONSTRUCTION. 7. CONTRACTOR IS TO PREVENT SURFACE AND AIR MOVEMENT OF DUST FROM DISTURBED SOIL SURFACES THAT MAY CAUSE OFF-SITE DAMAGE, HEALTH HAZARDS, AND/OR TRAFFIC SAFETY PROBLEMS. 8.INSTALL ADDITIONAL EROSION CONTROL MEASURES (I.E. SILT FENCE, DIVERSIONS) AS NECESSARY TO AVOID TRANSFER OF SEDIMENT FROM THE SITE OR AS DIRECTED BY THE EROSION CONTROL INSPECTOR. PHASE I EROSION CONTROL SEQUENCE 1.OBTAIN ALL NECESSARY PERMITS FROM THE PROPER AUTHORITIES, INCLUDING ENVIRONMENTAL IMPACT PERMITS. 2.INSTALL SILT FENCE, STONE OUTLETS, AND CONSTRUCTION ENTRANCE AS SHOWN ON THE PLAN IN ACCORDANCE WITH THE LATEST NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING DESIGN MANUAL. REMOVE ASPHALT AS NECESSARY FOR CONSTRUCTION ENTRANCE INSTALLATION. ANY SEDIMENT ACCUMULATION ON ADJACENT PUBLIC ROADS AS A RESULT OF THE PROJECT AND TRAFFIC FROM THE PROJECT SHALL BE IMMEDIATELY CLEANED OFF BY THE CONTRACTOR. 3.STREAM BUFFERS, FLOODPLAIN, AND ANY JURISDICTIONAL WETLANDS TO BE MARKED. 4.BEGIN DEMOLITION OF EXISTING TREES, AND ALL OTHER FEATURES TO BE REMOVED AS SHOWN ON DEMOLITION PLAN OR AS NEEDED WITHIN LIMITS OF DISTURBANCE. 5.CONSTRUCT SKIMMER BASINS AND DIVERSION DITCHES. INSTALL TEMPORARY CULVERTS AS WELL AS PERMANENT CULVERTS SHOWN ON PHASE 1 EROSION CONTROL PLAN. CALL FOR INSPECTION PRIOR TO OTHER GRADING ACTIVITIES. 6.BEGIN SITE GRADING ACTIVITIES AND WATER MAIN INSTALLATION. 7.WHILE GRADING ACTIVITIES ARE UNDERWAY, BEGIN CONSTRUCTION OF REMAINING CULVERTS AT STREAM. 8.ONCE STORM SEWER AND CULVERTS ARE CONSTRUCTED, CONSTRUCT RETAINING WALLS #1 AND #2 AND PERMANENT STREAM CROSSING BRIDGE. 9.CALL FOR INSPECTION. 10.ADJUST EROSION CONTROL MEASURES AS NECESSARY FOR PROPER OPERATION. INSTALL ADDITIONAL EROSION CONTROL MEASURES IF DETERMINED NECESSARY BY THE EROSION CONTROL INSPECTOR. 11.MONITOR EROSION CONTROL DEVICES AND REMOVE SEDIMENT ACCUMULATION TO ENSURE SYSTEM IS FUNCTIONING PROPERLY. 12.PROCEED TO EROSION CONTROL PHASE II ONCE MASS GRADING IS COMPLETE. SILT FENCE EROSION CONTROL LEGEND TEMPORARY CONSTRUCTION ENTRANCE PROPOSED CONTOUR EXISTING CONTOUR800 800 NOTE: CONTRACTOR SHALL INSPECT AND REPAIR ALL EROSION CONTROL DEVICES ONCE PER WEEK AND AFTER EVERY RAIN EVENT. DIVERSION DITCH POROUS BAFFLE SKIMMER DRAINAGE AREA LIMITS OF DISTURBANCE CHECK DAM PIPE/CULVERT INLET INLET PROTECTION PROTECTION TREE PROTECTIONTP INSET THIS SHEET INSET SCALE 1" = 60' CLEAR AND GRUB LIMITS OF DISTURBANCE = 29.92 ACRES X X OHPOHPOHPOHPOHPOHPOHPOHPOHPROBERT N. OGLESBY D.B. 3524 - PG. 1476 XXXPIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 PIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 20' UTILITY EASEMENT815805800800 800 797 795790785780777 776 775 77 4 772775780785786790795800805 810 80 5 810 812 814 815 810 805 765760 760765770768765761 7657707 7 0 7 6 5 764 7657707717707687 6 5 7 6 0 76 2 77577 0 7 7 5 77677 0 7 7 5 7 7 4 77375576076577076575575375575375 2 7507467 4 8 750745745748747742745748747740740741754748751743738 760755754775780 770OHPOHPOHPOHPXX20" TREE 28" TREE 100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) (5) UNKNOWN SIZE TREES 24" SYCAMORE CLEAR AND GRUB CLEAR AND GRUB CLEAN WATER DIVERSION (TYP) CULVERT INLET PROTECTION (TYP) RIPRAP OUTLET PROTECTION 20' L X 9' W X 16" THICKNESS D50 = 7" INLET PROTECTION (TYP) CLEAN WATER DIVERSION (TYP) TEMPORARY DIVERSION DITCH (TYP) SILT FENCE (TYP) SILT FENCE (TYP) SILT FENCE (TYP) CONSTRUCTION ENTRANCE (TYP) CULVERT INLET PROTECTION (TYP) RIPRAP OUTLET PROTECTION 20' L X 9' W X 16" THICKNESS D50 = 7" DRAINAGE AREA (TYP) DRAINAGE AREA (TYP) 25' EMERGENCY SPILLWAY EL: 777.00 2'X2' ENERGY DISSIPATOR 2" SKIMMER W/ 1.5" ORIFICE POROUS BAFFLE (TYP) SLOPE DRAIN (TYP) RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" TEMPORARY 18" CULVERT INV IN: 753.80 INV OUT: 752.30 15' EMERGENCY SPILLWAY EL: 749.00 2'X2' ENERGY DISSIPATOR 1.5" SKIMMER W/ 1.25" ORIFICE POROUS BAFFLE (TYP) SLOPE DRAIN (TYP) STREAM CROSSING 36 LF 7'X5'-1" ARCHED CMP INV IN: 746.26 INV OUT: 745.90 LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE SKIMMER BASIN #3 PHASE 1 DRAINAGE AREA = 3.61 AC PHASE 1 Q10 = 9.86 CFS SKIMMER BASIN #4 PHASE 1 DRAINAGE AREA = 2.09 AC PHASE 1 Q10 = 5.71 CFS SKIMMER BASIN #5 PHASE 1 DRAINAGE AREA = 2.91 AC PHASE 1 Q10 = 7.94 CF 0.69 AC 0.87 AC 0.36 AC 0.31 AC SURFACE ROUGHENING (TYP) SURFACE ROUGHENING (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP)TPTPTREE PROTECTION FENCING (TYP) LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE SILT FENCE (TYP) SILT FENCE (TYP)TPTPTPTPTP TREE PROTECTION FENCING (TYP) STOCKPILE (MAX. 3' HIGH) STOCKPILE AREA CLEAN WATER DIVERSION (TYP) CLEAN WATER DIVERSION (TYP) CLEAN WATER DIVERSION (TYP) MAINTAIN POSITIVE DRAINAGE (TYP) STOCKPILE AREA CONCRETE WASHOUT STATION (TYP) COFFER DAM W/ BY-PASS PUMP (TYP) SKIMMER BASIN #7 PHASE 1 DRAINAGE AREA = 1.72 AC PHASE 1 Q10 = 4.70 CFS SLOPE DRAIN (TYP) POROUS BAFFLE (TYP) 15' EMERGENCY SPILLWAY EL: 763.00 2'X2' ENERGY DISSIPATOR 2" SKIMMER W/ 2" ORIFICEPOROUS BAFFLE (TYP) SLOPE DRAIN (TYP) 1.5" SKIMMER W/ 1.25" ORIFICE SLOPE DRAIN (TYP) 10' EMERGENCY SPILLWAY EL: 765.00 JURISDICTIONAL TRIBUTARYFORSYTH COUNTYGUILFORD COUNTYC1.2 PHASE I EROSION CONTROL PLANM. MARTIN M. MARTIN R. RINGLER 1" = 60' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C1.1 - EROS.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSS:\107\44636-Coldwater\DWG\Sheet\CD\C1.1 - EROS.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin0 SCALE 1"=60' 120'60'NAD 83MATCHLINESHEET C1.1GROUND STABILIZATION SITE AREA DESCRIPTION STABILIZATION TIME FRAME STABILIZATION TIME EXCEPTIONS ·PERIMETER DIKES, SWALES, DITCHES, AND SLOPES ·HIGH QUALITY WATER (HQW) ZONES ·SLOPES STEEPER THAN 3:1 ·SLOPES 3:1 OR FLATTER ·ALL OTHER AREA WITH SLOPE FLATTER THAN 4:1 7 DAYS NONE 7 DAYS NONE 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1 14 DAYS ARE ALLOWED 14 DAYS 14 DAYS 7-DAYS FOR SLOPES GREATER THAN 50 FEET IN LENGTH NONE (EXCEPT FOR PERIMETERS AND HQW ZONES) * "EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE COMPLIANCE IMPRACTICABLE." (SECTION II. B (2)(b)) EROSION CONTROL NOTES 1.DO NOT WORK OR DISTURB LAND OUTSIDE LIMITS OF CONSTRUCTION. 2.ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL COMPLY WITH NCDEQ STANDARDS, SPECIFICATIONS, AND DETAILS. 3.INSPECT EROSION AND SEDIMENT CONTROL MEASURES WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. MAINTAIN MEASURES AS NECESSARY. 4.GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS BUT NO MORE THAN 21 CALENDAR DAYS AFTER COMPLETION OF ANY PHASE OF GRADING. PERMANENT GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS OR NO MORE THAN 21 CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION. 6. KEEP MUD OFF STREETS DURING CONSTRUCTION. 7. CONTRACTOR IS TO PREVENT SURFACE AND AIR MOVEMENT OF DUST FROM DISTURBED SOIL SURFACES THAT MAY CAUSE OFF-SITE DAMAGE, HEALTH HAZARDS, AND/OR TRAFFIC SAFETY PROBLEMS. 8.INSTALL ADDITIONAL EROSION CONTROL MEASURES (I.E. SILT FENCE, DIVERSIONS) AS NECESSARY TO AVOID TRANSFER OF SEDIMENT FROM THE SITE OR AS DIRECTED BY THE EROSION CONTROL INSPECTOR. NOTE: CONTRACTOR SHALL INSPECT AND REPAIR ALL EROSION CONTROL DEVICES ONCE PER WEEK AND AFTER EVERY RAIN EVENT. LIMITS OF DISTURBANCE = 29.92 ACRES COFFER DAM BY-PASS NOTES: 1.BYPASS OPERATIONS SHOULD BE ACTIVE ONLY DURING DRY WEATHER. CONTRACTOR TO SCHEDULE WORK ACTIVITY ACCORDINGLY. 2.TEMPORARY FAILSAFE BYPASS PUMPING SYSTEM TO BE CONSTRUCTED AND READY FOR OPERATION PRIOR TO PIPE PLACEMENT. 3.BYPASS SYSTEM MUST HAVE AN ADDITIONAL BACKUP PUMP AVAILABLE. 4.STREAM RECONSTRUCTION SHALL BE STARTED IMMEDIATELY AFTER COFFER DAM IS REMOVED. SILT FENCE EROSION CONTROL LEGEND TEMPORARY CONSTRUCTION ENTRANCE PROPOSED CONTOUR EXISTING CONTOUR800 800 DIVERSION DITCH POROUS BAFFLE SKIMMER DRAINAGE AREA LIMITS OF DISTURBANCE CHECK DAM PIPE/CULVERT INLET INLET PROTECTION PROTECTION WATTLE TREE PROTECTIONTP FLOODPLAIN PHASE I EROSION CONTROL SEQUENCE 1.OBTAIN ALL NECESSARY PERMITS FROM THE PROPER AUTHORITIES, INCLUDING ENVIRONMENTAL IMPACT PERMITS. 2.INSTALL SILT FENCE, STONE OUTLETS, AND CONSTRUCTION ENTRANCE AS SHOWN ON THE PLAN IN ACCORDANCE WITH THE LATEST NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING DESIGN MANUAL. REMOVE ASPHALT AS NECESSARY FOR CONSTRUCTION ENTRANCE INSTALLATION. ANY SEDIMENT ACCUMULATION ON ADJACENT PUBLIC ROADS AS A RESULT OF THE PROJECT AND TRAFFIC FROM THE PROJECT SHALL BE IMMEDIATELY CLEANED OFF BY THE CONTRACTOR. 3.STREAM BUFFERS, FLOODPLAIN, AND ANY JURISDICTIONAL WETLANDS TO BE MARKED. 4.BEGIN DEMOLITION OF EXISTING TREES, AND ALL OTHER FEATURES TO BE REMOVED AS SHOWN ON DEMOLITION PLAN OR AS NEEDED WITHIN LIMITS OF DISTURBANCE. 5.CONSTRUCT SKIMMER BASINS AND DIVERSION DITCHES. INSTALL TEMPORARY CULVERTS AS WELL AS PERMANENT CULVERTS SHOWN ON PHASE 1 EROSION CONTROL PLAN. CALL FOR INSPECTION PRIOR TO OTHER GRADING ACTIVITIES. 6.BEGIN SITE GRADING ACTIVITIES AND WATER MAIN INSTALLATION. 7.WHILE GRADING ACTIVITIES ARE UNDERWAY, BEGIN CONSTRUCTION OF REMAINING CULVERTS AT STREAM. 8.ONCE STORM SEWER AND CULVERTS ARE CONSTRUCTED, CONSTRUCT RETAINING WALLS #1 AND #2 AND PERMANENT STREAM CROSSING BRIDGE. 9.CALL FOR INSPECTION. 10.ADJUST EROSION CONTROL MEASURES AS NECESSARY FOR PROPER OPERATION. INSTALL ADDITIONAL EROSION CONTROL MEASURES IF DETERMINED NECESSARY BY THE EROSION CONTROL INSPECTOR. 11.MONITOR EROSION CONTROL DEVICES AND REMOVE SEDIMENT ACCUMULATION TO ENSURE SYSTEM IS FUNCTIONING PROPERLY. 12.PROCEED TO EROSION CONTROL PHASE II ONCE MASS GRADING IS COMPLETE. POTENTIALLY JURISDICTIONAL TRIBUTARY N 56° 1 0' 5 9 " E 199.9 6' PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: JURISDICTIONAL WETLAND 760 765 770 775 780 785 790 795 775780785790785 780 795 790 800 800802 795 790 785 790795800805810 810812 8 0 5 810815820825 8258 2 5820815810805800795790785 780775 770 770775 780 785 790795 800805810 805 800 79 5 803 830831830831830829 828 827 82 5 8 2 0 81 5 810 80 5 800 795 790 7 9 5 800805810815820825830832825820815805775780785 7807 7 0 76 9 7 7 5 795775775770765775 780 785 S76°1 3 ' 5 6 " E 2,215. 4 0 '750750750750 7707707707 7 0 SKIMMER BASIN #1 PHASE 2 DRAINAGE AREA = 9.46 AC PHASE 2 Q10 = 25.83 CFS SKIMMER BASIN #2 PHASE 2 DRAINAGE AREA = 1.48 AC PHASE 2 Q10 = 4.04 CFS RIPRAP OUTLET PROTECTION 8' L X 3.75' W X 7" THICKNESS D50 = 3" 59 LF 15" RCP INV IN: 794.00 INV OUT: 793.00 25' EMERGENCY SPILLWAY EL: 749.00 2'X2' ENERGY DISSIPATOR SILT FENCE (TYP) TEMPORARY DIVERSION DITCH (TYP) POROUS BAFFLE (TYP) 2.5" SKIMMER W/ 1.75" ORIFICE SILT FENCE (TYP) SILT FENCE (TYP) SILT FENCE (TYP) TEMPORARY DIVERSION DITCH (TYP) SLOPE DRAIN (TYP) SLOPE DRAIN (TYP) STONE OUTLET (TYP) 20' EMERGENCY SPILLWAY EL: 757.00 2'X2' ENERGY DISSIPATOR 2" SKIMMER W/ 1.25" ORIFICE POROUS BAFFLE (TYP) SILT FENCE (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" WATTLE (TYP) WATTLE (TYP) SLOPE DRAIN (TYP) WATTLE (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) MAINTAIN POSITIVE DRAINAGE (TYP) MAINTAIN POSITIVE DRAINAGE (TYP)780785 7907958008058108158208208258257 8 1 782783 784 7 8 6 7 8 7 7 8 8789 79179279379479 6 797798799801802803804806807808809811812813814816816817817818818819819821821822822823823824824826826827827775780785790 790790795 800 805 8 1 0 8 1 5 8 2 0 825830835 7747767777787797817827837847867877887897917 9 1791 7 9 2 792792793794 796797798799 801 802 803 804 806 807 808 8 0 9 8 1 1 8 1 2 8 1 3 8 1 4 8 1 6 8 1 7 8 1 8 8 1 9 8 2 1 822823824 82682782 7 827 828828 828829829 829831 832 833 834 836 837838 785790795786787788789791792793794796770775780S 00°22'16" W113.21'7807 7 0 76 9 7 7 5 7 5 0 7 7 0 750 STOCKPILE AREA (±51,050 SF) SKIMMER BASIN #6 PHASE 2 DRAINAGE AREA = 2.75 AC PHASE 2 Q10 = 7.50 CFS SILT FENCE (TYP) SILT FENCE (TYP) 15' EMERGENCY SPILLWAY EL: 747.00 2'X2' ENERGY DISSIPATOR 1.5" SKIMMER W/ 1.25" ORIFICEPOROUS BAFFLE (TYP) SLOPE DRAIN (TYP) JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C1.3 - EROS2.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSC1.3 PHASE II EROSION CONTROL PLANM. MARTIN M. MARTIN R. RINGLER 1" = 60' 0 SCALE 1"=60' 120'60'NAD 83MATCHLINESHEET C1.4EROSION CONTROL NOTES 1.DO NOT WORK OR DISTURB LAND OUTSIDE LIMITS OF CONSTRUCTION. 2.ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL COMPLY WITH NCDEQ STANDARDS, SPECIFICATIONS, AND DETAILS. 3.INSPECT EROSION AND SEDIMENT CONTROL MEASURES WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. MAINTAIN MEASURES AS NECESSARY. 4.GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS BUT NO MORE THAN 21 CALENDAR DAYS AFTER COMPLETION OF ANY PHASE OF GRADING. PERMANENT GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS OR NO MORE THAN 21 CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION. 6. KEEP MUD OFF STREETS DURING CONSTRUCTION. 7. CONTRACTOR IS TO PREVENT SURFACE AND AIR MOVEMENT OF DUST FROM DISTURBED SOIL SURFACES THAT MAY CAUSE OFF-SITE DAMAGE, HEALTH HAZARDS, AND/OR TRAFFIC SAFETY PROBLEMS. 8.INSTALL ADDITIONAL EROSION CONTROL MEASURES (I.E. SILT FENCE, DIVERSIONS) AS NECESSARY TO AVOID TRANSFER OF SEDIMENT FROM THE SITE OR AS DIRECTED BY THE EROSION CONTROL INSPECTOR. PHASE II EROSION CONTROL SEQUENCE 1.MAINTAIN ALL EROSION CONTROL MEASURES INSTALLED IN THE PHASE I EROSION CONTROL PLAN. 2.ADJUST EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY FOR PROPER OPERATION. INSTALL ADDITIONAL EROSION CONTROL MEASURES IF DETERMINED NECESSARY BY THE EROSION CONTROL INSPECTOR. 3.STABILIZE STOCKPILES, DAMS, DIKES AND DIVERSIONS WITH TEMPORARY GRASS SEEDING AND PROVIDE SILT FENCE AROUND THE PERIMETER OF STOCKPILES. SEE GROUND STABILIZATION TABLE FOR STABILIZATION TIME FRAMES. 4.ENSURE DRAINAGE PATTERN TO SKIMMER BASINS AT ALL TIMES AND ADJUST EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY FOR PROPER OPERATION. 5.BEGIN GRADING OPERATIONS. AS FILL OPERATIONS PROGRESS, REPLACE DIVERSION DIKES WITH FILL DIVERSIONS. ESTABLISH DIVERSIONS AT END OF EACH WORKING DAY. STABILIZE CUT AND FILL SLOPES AS NECESSARY WITH GRASS SEEDING AND MULCH. 6.INSTALLED MEASURES SHALL BE MAINTAINED OR REPLACED AS AREAS ARE STABILIZED AND WHEN STORM SEWER CONVEYANCES ARE INSTALLED AND FUNCTIONING WITH INLET PROTECTION. REMOVE ACCUMULATED SEDIMENT FROM EROSION CONTROL DEVICES. 7.COMPLETE MASS GRADING OPERATIONS AND GRADE SITE TO THE ELEVATIONS SHOWN ON THE PLAN. APPLY TEMPORARY AND PERMANENT SEEDING AND STABILIZE PROBLEM AREAS ON THE SITE. SEED AND MULCH DENUDED AREAS. SILT FENCE EROSION CONTROL LEGEND TEMPORARY CONSTRUCTION ENTRANCE PROPOSED CONTOUR EXISTING CONTOUR800 800 NOTE: CONTRACTOR SHALL INSPECT AND REPAIR ALL EROSION CONTROL DEVICES ONCE PER WEEK AND AFTER EVERY RAIN EVENT. DIVERSION DITCH POROUS BAFFLE SKIMMER DRAINAGE AREA LIMITS OF DISTURBANCE CHECK DAM PIPE/CULVERT INLET INLET PROTECTION PROTECTION WATTLE TREE PROTECTIONTP INSET THIS SHEET INSET SCALE 1" = 60' INSET THIS SHEET LIMITS OF DISTURBANCE = 29.92 ACRES X X OHPOHPOHPOHPOHPOHPOHPOHPOHPROBERT N. OGLESBY D.B. 3524 - PG. 1476 XXX241.95'129.37' 26.72' 31.87' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 PIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 20' UTILITY EASEMENT815805800800 800 797 795790785780777 776 775 77 4 772775780785786790795800805 810 80 5 810 812 814 815 810 805 765760 760765770768765761 7657707 7 0 7 6 5 764 7657707717707687 6 5 7 6 0 76 2 77577 0 7 7 5 77677 0 7 7 5 7 7 4 77375576076577076575575375575375 2 7507467 4 8 750745745748747742745748747740740741754748751743738 760755754775780 770S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'N88°30'30"E 380.47'OHPOHPOHPOHPXX20" TREE 28" TREE 100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) (5) UNKNOWN SIZE TREES 24" SYCAMORE SKIMMER BASIN #4 PHASE 2 DRAINAGE AREA = 5.68 AC PHASE 2 Q10 = 15.50 CFS ARCHED CULVERT PHASE 2 DRAINAGE AREA = 95.07 AC PHASE 2 Q10 = 102.71 CFS TPTPTPTPSTOCKPILE (MAX. 3' HIGH) STOCKPILE AREATP760 755750SKIMMER BASIN #5 PHASE 2 DRAINAGE AREA = 1.27 AC PHASE 2 Q10 = 3.47 CF RIPRAP OUTLET PROTECTION 20' L X 9' W X 16" THICKNESS D50 = 7" CULVERT INLET PROTECTION (TYP) RIPRAP OUTLET PROTECTION 20' L X 9' W X 16" THICKNESS D50 = 7" INLET PROTECTION (TYP) SILT FENCE (TYP) SILT FENCE (TYP) CULVERT INLET PROTECTION (TYP) DRAINAGE AREA (TYP) DRAINAGE AREA (TYP) 15' EMERGENCY SPILLWAY EL: 763.00 2'X2' ENERGY DISSIPATOR 2" SKIMMER W/ 2" ORIFICEPOROUS BAFFLE (TYP) RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" SLOPE DRAIN (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) TREE PROTECTION FENCING (TYP) RIPRAP OUTLET PROTECTION 10' L X 6' W X 7" THICKNESS D50 = 3" WATTLE (TYP) SILT FENCE (TYP) TREE PROTECTION FENCING (TYP) TEMPORARY DIVERSION DITCH (TYP) SILT FENCE (TYP) 2'X2' ENERGY DISSIPATOR 1.5" SKIMMER W/ 1.25" ORIFICE S75BN MATTING ON ALL PROPOSED SLOPES (3:1) AND GREATER (TYP) SILT FENCE (TYP)CLEAN WATER DIVERSION (TYP) CLEAN WATER DIVERSION (TYP) CONSTRUCTION ENTRANCE (TYP) STREAM CROSSING 15' EMERGENCY SPILLWAY EL: 749.00 POROUS BAFFLE (TYP) SLOPE DRAIN (TYP) STOCKPILE AREA CONCRETE WASHOUT STATION (TYP)TPTPSLOPE DRAIN (TYP) 1.5" SKIMMER W/ 1.25" ORIFICE POROUS BAFFLE (TYP) SKIMMER BASIN #7 PHASE 2 DRAINAGE AREA = 0.24 AC PHASE 2 Q10 = 0.66 CF 36 LF 7'X5'-1" ARCHED CMP INV IN: 746.26 INV OUT: 745.90 HEADWALL 755 760765 77 0 775780785790795800805810815 756 757758759761762763 764 766 767 768 76 9 7 7 1 7 7 2 7 7 3 7 7 4776777778779781782783784786787788789791792793794796797798799801802803804806807808809811812813814816817818819 775772773774775 77577578077177 1 7 7 2 7 7 2 772773773773 774774774776777778779781 FORSYTH COUNTYGUILFORD COUNTYC1.4 PHASE II EROSION CONTROL PLANM. MARTIN M. MARTIN R. RINGLER 1" = 60' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C1.3 - EROS2.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSS:\107\44636-Coldwater\DWG\Sheet\CD\C1.3 - EROS2.dwg | Plotted on 12/10/2020 1:31 PM | by Maegan Martin0 SCALE 1"=60' 120'60'NAD 83MATCHLINESHEET C1.3GROUND STABILIZATION SITE AREA DESCRIPTION STABILIZATION TIME FRAME STABILIZATION TIME EXCEPTIONS ·PERIMETER DIKES, SWALES, DITCHES, AND SLOPES ·HIGH QUALITY WATER (HQW) ZONES ·SLOPES STEEPER THAN 3:1 ·SLOPES 3:1 OR FLATTER ·ALL OTHER AREA WITH SLOPE FLATTER THAN 4:1 7 DAYS NONE 7 DAYS NONE 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1 14 DAYS ARE ALLOWED 14 DAYS 14 DAYS 7-DAYS FOR SLOPES GREATER THAN 50 FEET IN LENGTH NONE (EXCEPT FOR PERIMETERS AND HQW ZONES) * "EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE COMPLIANCE IMPRACTICABLE." (SECTION II. B (2)(b)) EROSION CONTROL NOTES 1.DO NOT WORK OR DISTURB LAND OUTSIDE LIMITS OF CONSTRUCTION. 2.ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL COMPLY WITH NCDEQ STANDARDS, SPECIFICATIONS, AND DETAILS. 3.INSPECT EROSION AND SEDIMENT CONTROL MEASURES WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL. MAINTAIN MEASURES AS NECESSARY. 4.GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS BUT NO MORE THAN 21 CALENDAR DAYS AFTER COMPLETION OF ANY PHASE OF GRADING. PERMANENT GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS OR NO MORE THAN 21 CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION. 6. KEEP MUD OFF STREETS DURING CONSTRUCTION. 7. CONTRACTOR IS TO PREVENT SURFACE AND AIR MOVEMENT OF DUST FROM DISTURBED SOIL SURFACES THAT MAY CAUSE OFF-SITE DAMAGE, HEALTH HAZARDS, AND/OR TRAFFIC SAFETY PROBLEMS. 8.INSTALL ADDITIONAL EROSION CONTROL MEASURES (I.E. SILT FENCE, DIVERSIONS) AS NECESSARY TO AVOID TRANSFER OF SEDIMENT FROM THE SITE OR AS DIRECTED BY THE EROSION CONTROL INSPECTOR. PHASE II EROSION CONTROL SEQUENCE 1.MAINTAIN ALL EROSION CONTROL MEASURES INSTALLED IN THE PHASE I EROSION CONTROL PLAN. 2.ADJUST EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY FOR PROPER OPERATION. INSTALL ADDITIONAL EROSION CONTROL MEASURES IF DETERMINED NECESSARY BY THE EROSION CONTROL INSPECTOR. 3.STABILIZE STOCKPILES, DAMS, DIKES AND DIVERSIONS WITH TEMPORARY GRASS SEEDING AND PROVIDE SILT FENCE AROUND THE PERIMETER OF STOCKPILES. SEE GROUND STABILIZATION TABLE FOR STABILIZATION TIME FRAMES. 4.ENSURE DRAINAGE PATTERN TO SKIMMER BASINS AT ALL TIMES AND ADJUST EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY FOR PROPER OPERATION. 5.BEGIN GRADING OPERATIONS. AS FILL OPERATIONS PROGRESS, REPLACE DIVERSION DIKES WITH FILL DIVERSIONS. ESTABLISH DIVERSIONS AT END OF EACH WORKING DAY. STABILIZE CUT AND FILL SLOPES AS NECESSARY WITH GRASS SEEDING AND MULCH. 6.INSTALLED MEASURES SHALL BE MAINTAINED OR REPLACED AS AREAS ARE STABILIZED AND WHEN STORM SEWER CONVEYANCES ARE INSTALLED AND FUNCTIONING WITH INLET PROTECTION. REMOVE ACCUMULATED SEDIMENT FROM EROSION CONTROL DEVICES. 7.COMPLETE MASS GRADING OPERATIONS AND GRADE SITE TO THE ELEVATIONS SHOWN ON THE PLAN. APPLY TEMPORARY AND PERMANENT SEEDING AND STABILIZE PROBLEM AREAS ON THE SITE. SEED AND MULCH DENUDED AREAS. SILT FENCE EROSION CONTROL LEGEND TEMPORARY CONSTRUCTION ENTRANCE PROPOSED CONTOUR EXISTING CONTOUR800 800 NOTE: CONTRACTOR SHALL INSPECT AND REPAIR ALL EROSION CONTROL DEVICES ONCE PER WEEK AND AFTER EVERY RAIN EVENT. DIVERSION DITCH POROUS BAFFLE SKIMMER DRAINAGE AREA LIMITS OF DISTURBANCE CHECK DAM PIPE/CULVERT INLET INLET PROTECTION PROTECTION WATTLE TREE PROTECTIONTP LIMITS OF DISTURBANCE = 29.92 ACRES FLOODPLAIN OHPOHPOHPXPOTENTIALLY JURISDICTIONAL WETLAND JURISDICTIONAL TRIBUTARIES POTENTIALLY JURISDICTIONAL TRIBUTARY S 87°40'37" W ( 294.01' ) S 87°40'37" W 1483.80'S 00°22'16" W113.21'263.96' N 56° 1 0' 5 9 " E 199.9 6' NIP 241.95'129.37'248.07'349.82' N 88°33'53" E ( 1027.80' ) 26.72' 31.87' S 87°40'37" W 340.74' ( 400.84' )S 01°23'25" W339.60'N 89°37'18" W ( 441.61' ) EIP 165.75'275.86' N 88°33'53" E 31.87' ± 21.276 ACRES CONCRETE MONUMENTFORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTYELLIPTICAL CMP 9.5'x6' INV.: 744.27' ELLIPTICAL CMP 9.5'x6' INV.: 743.95' 18"CMP INV.: 742.89' 18"CMP INV.: 742.40' 15"RCP INV.: 737.78' ELLIPTICAL CMP 11.5'x7' INV.: 728.41' ELLIPTICAL CMP 11.5'x7' INV.: 728.34' 18"CMP INV.: 743.15'18"CMP INV.: 742.00' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 PIN: 6990-54-1459-000 N/F: DUKE POWER COMPANY DB 2495 PG 509 ZONING: PIN: 6990-34-9796 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-15-7869.00 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: PIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PJURISDICTIONAL WETLAND S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'N88°30'30"E 380.47'OHPOHPOHPOHPOHP100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) TREE EDGE (TYP)C12317.05 '240.25'225.00'227.13'221.82'225.00'238.46'248.71'282.74'141. 5 0' 357.65' 345.46' 284. 7 4 ' 2 6 5 . 5 7 ' 267 . 1 0 ' 277. 5 8 ' 29 8 . 4 8 ' 25 7 . 9 7 ' 291.32'225.00'303.12'270.50'142.87'264.15'252.40'243.03 '224.91'236.51'243.81'277.10'338.47'150.96'150.90'155.86' 129.24'32.95'160.69'105.27'207.93 '224.97'283.89 ' 278.0 1 ' 257.94' 300.2 4 ' 1 7 3 . 3 1 ' 21 9 . 1 1 '173.93'184.82'96.24'107.16'116.62'107.60'113.03'12 1 . 2 1 '279.01'3 2 7 . 0 5 '134.69'97.44'100.24'92.93'69.91'40.88'40.88'64.22'139.70'36.1 3'60.0 4' C1 C2 L6C3L7C4C5C6 C7 C8C9 C10C11L8C13L9C14 C1 5 C16 C17 C18C19 L10 L11 C20L12C21C22L13L14C23C24C25C26C 2 7 C28 L15 L16 L17 C29 C30 C31 L18 L19 C32 C33 C34 L20 L21 C35 C36 C37C38C39 L22 C40 C41L23C42C43C44 L24L25 C45 C46L26L27C47C48C49 L28L29L31 C 5 0C51L32L33 C52C53C54L34C55 L35 L36 C56 C5 7 C5 8 C59 L37 C60 C61 L38 C62 C63 L39 C64C65 L40 L41 C66C67L42 C68C69 L43 C70 C7 1 C7 2 C73 L44 L45 L46 L47 L48 L49 C74 99.98'119.40'5 1 . 2 0 ' 67.85' 31.81'104.9 3' 34.9 8' 37.21' 2 0 7 . 3 8 ' 206.09'67.75'261.87'275.21'245.84'225.88'231.39'226.71'225.45'225.12'195.02'195.34'121.45 '59.52'C77 C78L 1 199.57'70.02' 71.75'124.27' 103.39'113.21'BOATHOUSE WAY (50' PUBLIC R/W) BOATHOUSE WAY (50' PUBLIC R/W) BRIGHT WATER LANE (50' PUBLIC R/W) COLD WATER TERRACE (50' PUBLIC R/W) COLD WATER TERRACE (50' PUBLIC R/W) 16 3 . 2 3 ' 99.27'53.39 '60.10'59.2 6' 119.8 5' 161.18' 195.41' 65.38'66.80'17. 6 1 ' 25.11' 23.00'224.94'213.76'CURVE TABLE CURVE C1 C2 C3 C4 C5 C6 C7 C8 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 RADIUS 435.00 435.00 647.11 375.00 375.00 18.50 59.50 59.50 59.50 18.50 425.00 475.58 15.14 225.34 225.00 225.52 225.00 18.00 18.00 475.00 LENGTH 161.68 130.17 85.40 57.09 29.11 19.58 68.16 92.83 36.18 16.88 104.44 47.04 22.67 121.46 25.02 95.99 168.52 26.75 28.27 115.97 TANGENT 81.78 65.57 42.76 28.60 14.56 10.82 38.37 58.88 18.67 9.08 52.49 23.54 14.07 62.24 12.52 48.73 88.43 16.54 18.00 58.27 DELTA 21°17'43" 17°08'42" 7°33'41" 8°43'20" 4°26'54" 60°37'59" 65°37'54" 89°23'43" 34°50'37" 52°16'53" 14°04'50" 5°40'04" 85°48'01" 30°52'57" 6°22'13" 24°23'13" 42°54'50" 85°08'48" 90°00'01" 13°59'19" CHORD BEARING S80°47'49"W S61°34'37"W S36°58'44"W N37°15'34"E N43°50'41"E N76°23'07"E S73°53'10"W S18°24'27"E N12°07'09"E S20°50'17"W N39°56'18"E S35°35'43"W N89°01'14"W S67°02'03"E S85°41'00"E N73°47'42"E N40°06'34"E S61°13'33"W N31°12'03"W N20°47'37"E CHORD 160.75 129.68 85.34 57.03 29.11 18.68 64.49 83.70 35.63 16.30 104.18 47.02 20.61 119.99 25.00 95.27 164.61 24.36 25.46 115.68 CURVE TABLE CURVE C22 C23 C24 C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C40 C41 RADIUS 476.94 250.00 250.00 250.00 250.00 250.00 250.00 625.00 775.00 775.00 575.00 525.00 525.00 325.83 325.00 325.00 325.00 575.00 275.00 18.00 LENGTH 99.34 26.60 98.55 101.20 102.88 139.69 86.70 115.29 16.53 126.42 119.71 62.01 47.29 75.67 118.28 99.89 230.85 71.86 83.23 25.62 TANGENT 49.85 13.31 49.92 51.30 52.18 71.72 43.79 57.81 8.27 63.35 60.07 31.04 23.66 38.00 59.80 50.34 120.53 35.97 41.94 15.53 DELTA 11°56'01" 6°05'43" 22°35'10" 23°11'38" 23°34'41" 32°00'53" 19°52'09" 10°34'08" 1°13'21" 9°20'48" 11°55'41" 6°46'02" 5°09'39" 13°18'20" 20°51'05" 17°36'35" 40°41'49" 7°09'36" 17°20'28" 81°33'39" CHORD BEARING N33°46'45"E S36°43'23"W S22°22'56"W S0°30'28"E S23°53'37"E S51°41'25"E S82°23'18"E N82°23'33"E S77°43'09"W S83°00'13"W N86°21'32"W S83°46'43"E S89°44'33"E N81°00'25"E N63°54'41"E N44°40'51"E N15°31'39"E N72°37'14"W S77°42'41"E N45°36'05"W CHORD 99.16 26.58 97.91 100.51 102.15 137.88 86.26 115.13 16.53 126.28 119.49 61.97 47.27 75.50 117.62 99.50 226.02 71.81 82.91 23.51 CURVE TABLE CURVE C42 C43 C44 C45 C46 C47 C48 C49 C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C60 C61 RADIUS 275.00 275.00 275.00 475.00 625.29 825.00 825.00 575.00 200.00 200.00 525.00 521.36 525.00 18.00 475.00 483.59 525.00 522.03 525.00 525.00 LENGTH 107.25 223.00 113.71 96.40 132.61 119.47 32.71 106.07 258.70 202.39 41.73 125.60 70.64 28.27 91.69 59.15 93.64 73.08 68.14 77.80 TANGENT 54.32 118.04 57.68 48.36 66.55 59.84 16.36 53.18 151.02 110.82 20.88 63.11 35.37 18.00 45.99 29.61 46.95 36.60 34.12 38.97 DELTA 22°20'47" 46°27'39" 23°41'26" 11°37'39" 12°09'03" 8°17'50" 2°16'19" 10°34'08" 74°06'45" 57°58'52" 4°33'17" 13°48'12" 7°42'31" 90°00'00" 11°03'34" 7°00'31" 10°13'10" 8°01'15" 7°26'13" 8°29'28" CHORD BEARING N6°21'08"E N40°45'21"E N75°49'54"E S86°30'33"E N86°14'59"W S83°31'42"W S78°14'38"W N82°23'33"E S55°16'01"E S10°46'48"W N37°29'36"E N28°20'16"E N17°39'13"E S58°47'58"W N70°40'15"W N61°34'25"W S63°06'56"E S72°12'47"E S79°55'09"E S87°52'59"E CHORD 106.58 216.94 112.90 96.23 132.36 119.37 32.71 105.92 241.04 193.87 41.72 125.30 70.58 25.46 91.54 59.12 93.52 73.02 68.10 77.73 CURVE TABLE CURVE C62 C63 C64 C65 C66 C67 C68 C69 C70 C71 C72 C73 C74 C77 C78 RADIUS 475.00 475.00 224.92 625.00 525.00 525.00 475.00 475.00 475.00 475.00 525.00 525.00 435.00 435.00 373.93 LENGTH 47.08 84.97 78.85 78.10 123.37 22.58 93.75 38.30 87.25 63.59 104.37 62.35 84.31 110.63 35.02 TANGENT 23.56 42.60 39.83 39.10 61.97 11.29 47.03 19.16 43.75 31.84 52.36 31.21 42.29 55.61 17.52 DELTA 5°40'44" 10°14'56" 20°05'09" 7°09'36" 13°27'51" 2°27'49" 11°18'29" 4°37'12" 10°31'29" 7°40'13" 11°23'27" 6°48'15" 11°06'17" 14°34'16" 5°21'56" CHORD BEARING N89°17'21"W N81°19'31"W S79°04'57"E N72°37'14"W N82°55'58"W S89°06'12"W S86°28'28"E S78°30'38"E S70°56'18"E S61°50'27"E N63°42'04"W N72°47'55"W N83°00'11"W S45°43'08"W S41°06'49"W CHORD 47.06 84.85 78.44 78.05 123.09 22.57 93.59 38.29 87.13 63.54 104.20 62.31 84.18 110.33 35.00 LINE TABLE LINE L1 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L24 L25 L26 LENGTH 31.44 57.69 27.31 26.13 92.37 175.15 226.92 40.30 92.99 86.14 15.90 179.17 51.17 47.82 34.16 132.77 77.52 111.68 73.97 36.23 BEARING S51°34'09"E S38°08'59"W S32°53'54"W N32°53'54"E N38°25'51"E S76°12'03"E S76°12'03"E S13°47'58"W S39°46'14"W S39°46'14"W N87°40'37"E N87°40'37"E N87°40'37"E N87°40'37"E N87°40'37"E N87°40'37"E N87°40'37"E S87°40'37"W S87°40'37"W S87°40'37"W LINE TABLE LINE L27 L28 L29 L31 L32 L33 L34 L35 L36 L37 L38 L39 L40 L41 L42 L43 L44 L45 L46 L47 LENGTH 46.78 11.46 146.95 87.84 78.84 100.29 40.30 270.30 33.20 22.18 42.30 72.53 55.35 53.00 42.30 22.18 141.28 150.22 147.88 178.02 BEARING S87°42'17"W S87°40'37"W S87°40'37"W S87°40'37"W N39°42'32"E N39°49'09"E N13°47'58"E S76°12'02"E S76°12'02"E S76°12'02"E N87°52'17"E S76°12'02"E N76°12'02"W N76°12'02"W S87°52'17"W N76°12'02"W N76°12'30"W N76°12'03"W N76°11'29"W N76°12'31"W LINE TABLE LINE L48 L49 LENGTH 91.87 32.47 BEARING N76°11'09"W N76°22'50"W C2.0 OVERALL SUBDIVISION PLANM. MARTIN M. MARTIN R. RINGLER 1" = 150' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSS:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin0 300' SCALE 1"=150' 150'NAD 83NOTES: 1.ALL PROPOSED ROADS ARE TO BE NCDOT MAINTAINED. 2.ALL LOTS SHALL BE SERVED WITH PRIVATE SEPTIC. 3.ALL LOTS SHALL BE SERVED WITH PUBLIC WATER. 4.BOUNDARY SURVEY PROVIDED BY VAUGHN SURVEYING CO., INC. DATED MARCH 25, 2019. TYPICAL RESIDENTIAL COLLECTOR ROAD N.T.S C2.1 C2.2 C2.3 C2.4 C2.5 1.TYPE OF SUBMITTAL:CONSTRUCTION DOCUMENTS 2.DEVELOPMENT:COLDWATER (PROJECT ID: 349867) 3.PIN #:6690-35-6657 (FORSYTH), 6990-45-8600 (GUILFORD) 4.ADDRESS:8228 COLDWATER ROAD, STOKESDALE, NC 27357 5.CURRENT ZONING:RS-40S (FORSYTH), AG (GUILFORD) 6.ADJACENT ZONING:AG, RS-40S 7.PROPOSED ZONING: RS-40S (FORSYTH), AG (GUILFORD) 8.PROPOSED USE:RESIDENTIAL BUILDING SINGLE-FAMILY 9.ADJACENT USE:RESIDENTIAL SINGLE-FAMILY, VACANT 10.DEED BOOK REFERENCE:DB 7787 - PG 2290 (GUILFORD), DB 3273 - PG 1847 (FORSYTH) 11.PROJECT LOT AREA:11.89 AC (GUILFORD), 66.39 AC (FORSYTH) ; 78.279 AC TOTAL 12.TOTAL # OF LOTS:56 SINGLE-FAMILY (2 REMOTE SEPTIC) 13.DENSITY:56 UNITS / 78.279 AC = 0.72 UNITS/AC 14.COORDINATES:36.23, -80.04 15.RIVER BASIN:ROANOKE RIVER BASIN 16.SOIL TYPES:FaC, Gu, PpC2, PpD2, FeE2, FaD, DaA 17.WATERSHED:DAN RIVER (UNPROTECTED) 18.LINEAR FOOTAGE OF STREET:6,702 LF (PUBLIC) 19.BUILT UPON AREA:3.35 AC (4.28%) 20.PARKING REQUIRED:1 SPACE PER 125 SF OF POOL AREA (FUTURE POOL) 1 SPACE PER 25 LOTS (FOR CLUSTER BOX UNIT) = (1,000 SF (POOL)/ 125 SF) + (56 LOTS/ 25 LOTS) = 8 SPACES + 3 SPACES = 11 PARKING SPACES REQUIRED 21.PARKING PROVIDED:11 SPACES (1 ADA/ VAN ACCESSIBLE SPACE) SITE DATA POTENTIALLY JURISDICTIONAL TRIBUTARY N 56° 1 0' 5 9 " E 199.9 6' PIN: 6990-15-7869.00 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG JURISDICTIONAL WETLAND BENT 1/2"IPF C1240,938 SF 40,146 SF 62,184 SF 40,230 SF 40,186 SF 40,371 SF 40,660 SF 48,425 SF 1 2 3 4 5 6 7 8 10** 11 12 13 14 15 16 38 55 47,182 SF 54 42,032 SF 45,118 SF 40,060 SF 40,258 SF 40,915 SF 40,194 SF 60,045 SF 47,703 SF 40,554 SF 44,806 SF 56 9 6A 28,253 SF 20A 20,229 SF 20' PUBLIC DRAINAGE EASEMENT 345.46' 284. 7 4 ' 2 6 5 . 5 7 ' 267 . 1 0 ' 25 7 . 9 7 '207.93 '224.97'283.89 ' 278.0 1 ' 257.94' 300.2 4 ' 1 7 3 . 3 1 ' 21 9 . 1 1 '173.93'184.82'96.24'107.16'116.62'107.60'113.03'12 1 . 2 1 '134.69'97.44'100.24'92.93'69.91'40.88'40.88'64.22'139.70'36.1 3' 60.0 4' C1 C2 L6C3L7C4C5C6 C7 C8C9 C10C11L8C13L9C14 C1 5 C16 C17 C18C19 L10 L11 C20C21C22L13L14C23C24C51L32L33C52C53L46 L47 L48 L49 C74 99.98'119.40'5 1 . 2 0 ' 37.21'225.12'59.52'C77 C78L 1 199.57' 20 FT ACCESS LANE TO LAKE REMOTE SEPTIC AREA FOR LOT #20 REMOTE SEPTIC AREA FOR LOT #6COLDWATER TERRACE(50' R/W) BRIGHT WATER LANE (50' R/W) COLD W A T E R T E R R A C E (50' R/ W )BOATHOUSE WAY (50' R/W) 20' PUBLIC DRAINAGE EASEMENT â„„R410' â„„R200' â„„R500' â„„R400' 20' 20' R30' R30' 9' 17.5' R30'R30' 20' R20'R20' 26' R5' 16 3 . 2 3 ' 99.27'53.39 ' R33.5' R44.5' 10' PRIVATE SEPTIC EASEMENT 10' PRIVATE SEPTIC EASEMENT (DESIGNATED OPEN SPACE) (DESIGNATED OPEN SPACE) FUTURE OPEN MAIL KIOSK COMMUNITY CENTER 20' PUBLIC DRAINAGE EASEMENT HANDICAP PARKING SIGNAGE (TYP) 9' 9' R76'R50' R5' WHEEL STOP (TYP) 195.41' 65.38' 66.80' 17. 6 1 ' 25.11' 23.00'224.94'24" STOP BAR & STOP SIGN 213.76'49,262 SF RETAINING WALL DESIGNED BY OTHERS (TYP) RETAINING WALL DESIGNED BY OTHERS (TYP) PHA S E 1 PHA S E 2 C2.1 SUBDIVISION PLAN - NWM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83NOTES: 1.ALL PROPOSED ROADS ARE TO BE NCDOT MAINTAINED. 2.ALL LOTS SHALL BE SERVED WITH PRIVATE SEPTIC. 3.ALL LOTS SHALL BE SERVED WITH PUBLIC WATER. 4.SEE SHEET C2.0 FOR SITE DATA. 5.SEE SHEET C2.0 FOR LINE AND CURVE DATA CHARTS. SITE LEGEND XEXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPERTY LINE FENCE SIGN WHEEL STOP PROPERTY SETBACK EASEMENT LIGHT DUTY ASPHALT HEAVY DUTY ASPHALT CONCRETE SIDEWALKS HEAVY DUTY CONCRETE MATCHLINESHEET C2.2MATCHLINE SHEET C2.3 NO SCALE DENOTES ASPHALT PAVEMENT ON PLANS 6" NCDOT ABC STONE 2" NCDOT S-9.5B (PLACED IN SINGLE LIFT) 6" COMPACTED SUBGRADE (100% ASTM D698) LIGHT DUTY PAVEMENT SECTION (PARKING STALLS) PAVEMENT SECTIONS RECOMMENDED/ ARE BASED ON THE GEOTECH REPORT PREPARED BY FROEHLING & ROBERTSON, INC. DATED APRIL 14, 2020. NO SCALE HEAVY DUTY PAVEMENT SECTION DENOTES ASPHALT PAVEMENT ON PLANS 6" NCDOT ABC STONE 1.5" NCDOT S-9.5B 2.5" NCDOT I-19.0B PAVEMENT SECTIONS RECOMMENDED/ ARE BASED ON THE GEOTECH REPORT PREPARED BY FROEHLING & ROBERTSON, INC. DATED APRIL 14, 2020. 6" COMPACTED SUBGRADE (100% ASTM D698) X X X X XXXFORSYTH COUNTYGUILFORD COUNTYPIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 CMNF CMNF S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'X X28" TREE 40,083 SF 40,313 SF 30 38 39 40 40,168 SF 54 40,289 SF 45,590 SF 48,553 SF 40,387 SF 40,923 SF 43,399 SF 42,032 SF 4645 44 43 42 41 40,258 SF 29 40,111 SF 40,407 SF 41,463 SF 40,174 SF 41,219 SF 46,281 SF 53 52 51 50 49 48 47 40,427 SF 20' DRAINAGE EASEMENT 20' PUBLIC DRAINAGE EASEMENT 277. 5 8 ' 29 8 . 4 8 ' 25 7 . 9 7 '142.87'264.15'252.40'277.10'338.47'150.96' 150.90' 155.86' 129.24'32.95' 160.69'105.27'L11 C20L12C21C22C38C39 L22 C40 C41L23C42L33C52C53C54L34C55 L35 L36 C56 C5 7 C5 8 C59 L37 C60 C61 L38 C62 C63 L39 C64 C65 L40 L41 C66 C67L42 C68 C69L43 C70 C7 1 C7 2 C73 L44 L45 L46 31.81' 104.93'34.98'261.87'275.21'245.84'225.88'231.39'226.71'225.45'195.02'195.34'PHASE 1 (42.73 AC) COLD W A T E R T E R R A C E (50' R/ W ) COLD W A T E R T E R R A C E (50' R/ W )BOATHOUSE WAY(50' R/W)â„„R250' â„„R300' â„„R500'â„„R500' â„„R600' â„„R500' â„„R500' â„„R500' R30' R30'R30' 20' 20' 20' 20' R30' PHASE BOUNDARY 24" STOP BAR & STOP SIGN 24" STOP BAR & STOP SIGN 24" STOP BAR & STOP SIGN PHASE 2PHASE 1PH A S E 1 PH A S E 2 C2.2 SUBDIVISION PLAN - NEM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83TYPICAL RESIDENTIAL COLLECTOR ROAD N.T.S SITE LEGEND XEXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPERTY LINE FENCE SIGN WHEEL STOP PROPERTY SETBACK EASEMENT LIGHT DUTY ASPHALT HEAVY DUTY ASPHALT CONCRETE SIDEWALKS HEAVY DUTY CONCRETE MATCHLINESHEET C2.1MATCHLINE SHEET C2.4 NOTES: 1.ALL PROPOSED ROADS ARE TO BE NCDOT MAINTAINED. 2.ALL LOTS SHALL BE SERVED WITH PRIVATE SEPTIC. 3.ALL LOTS SHALL BE SERVED WITH PUBLIC WATER. 4.SEE SHEET C2.0 FOR SITE DATA. 5.SEE SHEET C2.0 FOR LINE AND CURVE DATA CHARTS.SHEET C2.5MATCHLINENO SCALE HEAVY DUTY PAVEMENT SECTION DENOTES ASPHALT PAVEMENT ON PLANS 6" NCDOT ABC STONE 1.5" NCDOT S-9.5B 2.5" NCDOT I-19.0B PAVEMENT SECTIONS RECOMMENDED/ ARE BASED ON THE GEOTECH REPORT PREPARED BY FROEHLING & ROBERTSON, INC. DATED APRIL 14, 2020. 6" COMPACTED SUBGRADE (100% ASTM D698) PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: 69,741 SF 86,073 SF 56,364 SF 40,230 SF 10**16 17 37 38 42,032 SF 44,535 SF 60,045 SF 18 19 20 47,703 SF 42,587 SF 20' PUBLIC DRAINAGE EASEMENT 282.74'141. 5 0' 357.65' 345.46' 25 7 . 9 7 ' 291.32'184.82'279.01'134.69'97.44'100.24'C24C25C26C 2 7 C28 L15 C 5 0C51 67.85'206.09'70.02' 71.75' 124.27' PHASE 2 (33.21 AC) FLOODWAY FROM BELEWS LAKE FOLLOWS PROPERTY LINE 20 FT COMMUNITY ACCESS LANE AND OPEN SPACE AREA REMOTE SEPTIC AREA FOR LOT #6 â„„R225' 20'60.10'59.2 6' 119.8 5' 161.18'213.76'C2.3 SUBDIVISION PLAN - SWM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83SITE LEGEND XEXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPERTY LINE FENCE SIGN WHEEL STOP PROPERTY SETBACK EASEMENT LIGHT DUTY ASPHALT HEAVY DUTY ASPHALT CONCRETE SIDEWALKS HEAVY DUTY CONCRETE MATCHLINESHEET C2.4SHEET C2.1 MATCHLINE NOTES: 1.ALL PROPOSED ROADS ARE TO BE NCDOT MAINTAINED. 2.ALL LOTS SHALL BE SERVED WITH PRIVATE SEPTIC. 3.ALL LOTS SHALL BE SERVED WITH PUBLIC WATER. 4.SEE SHEET C2.0 FOR SITE DATA. 5.SEE SHEET C2.0 FOR LINE AND CURVE DATA CHARTS. NO SCALE HEAVY DUTY PAVEMENT SECTION DENOTES ASPHALT PAVEMENT ON PLANS 6" NCDOT ABC STONE 1.5" NCDOT S-9.5B 2.5" NCDOT I-19.0B PAVEMENT SECTIONS RECOMMENDED/ ARE BASED ON THE GEOTECH REPORT PREPARED BY FROEHLING & ROBERTSON, INC. DATED APRIL 14, 2020. 6" COMPACTED SUBGRADE (100% ASTM D698) S 87°40'37" W 1483.80'S 00°22'16" W113.21'FORSYTH COUNTYGUILFORD COUNTYPIN: 6990-34-9796 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG 20" TREE TREE EDGE (TYP) 57,166 SF 41,417 SF 41,010 SF40,533 SF 54,596 SF 42,314 SF 41,544 SF 40,206 SF 23 24 26 30 31 28 33 34 35 36 37 38 42,032 SF 44,535 SF 40,100 SF 43,975 SF 42,035 SF 42,724 SF 40,049 SF 40,260 SF 40,002 SF 20 22 25 21 27 42,587 SF 32 20' PUBLIC DRAINAGE EASEMENT 20' PUBLIC DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 317.05 '240.25'225.00'227.13'221.82'225.00'238.46'248.71'25 7 . 9 7 ' 291.32'225.00'303.12'270.50'243.03 '224.91'236.51'243.81'150.96' 150.90' 155.86' 129.24'32.95' 160.69'105.27'3 2 7 . 0 5 ' C28 L15 L16 L17 C29 C30 C31 L18 L19 C32 C33 C34 L20 L21 C35 C36 C37C38C42C43C44 L24L25 C45C46L26L27 C47 C48C49 L28L29L31 31.81' 104. 93' 34.98' 2 0 7 . 3 8 ' 206.09'67.75' 124.27' 103.39'113.21'10 FT PUBLIC ACCESS EASEMENT BOATHOUSE WAY (50' R/W) â„„R300' â„„R300' â„„R500' â„„R600' â„„R800' â„„R600' 20' 20' PH A S E 1 PH A S E 2 C2.4 SUBDIVISION PLAN - SEM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83SITE LEGEND XEXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPERTY LINE FENCE SIGN WHEEL STOP PROPERTY SETBACK EASEMENT LIGHT DUTY ASPHALT HEAVY DUTY ASPHALT CONCRETE SIDEWALKS HEAVY DUTY CONCRETEMATCHLINESHEET C2.3SHEET C2.2 MATCHLINE NOTES: 1.ALL PROPOSED ROADS ARE TO BE NCDOT MAINTAINED. 2.ALL LOTS SHALL BE SERVED WITH PRIVATE SEPTIC. 3.ALL LOTS SHALL BE SERVED WITH PUBLIC WATER. 4.SEE SHEET C2.0 FOR SITE DATA. 5.SEE SHEET C2.0 FOR LINE AND CURVE DATA CHARTS. NO SCALE HEAVY DUTY PAVEMENT SECTION DENOTES ASPHALT PAVEMENT ON PLANS 6" NCDOT ABC STONE 1.5" NCDOT S-9.5B 2.5" NCDOT I-19.0B PAVEMENT SECTIONS RECOMMENDED/ ARE BASED ON THE GEOTECH REPORT PREPARED BY FROEHLING & ROBERTSON, INC. DATED APRIL 14, 2020. 6" COMPACTED SUBGRADE (100% ASTM D698) X X OHPOHPOHPOHPOHPOHPOHPXXXPOTENTIALLY JURISDICTIONAL WETLAND JURISDICTIONAL TRIBUTARIES 241.95'129.37'248.07' 349.82' N 88°33'53" E ( 1027.80' ) 26.72' 31.87'S 09°08'49" W808.34'N 88°33'53" E 31.87' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PBARBED WIRE FENCE ENCROACHES 1/2"IPF CMNF CMNF N01°17'26"E243.18'N88°30'30"E 380.47'OHPX XX30' STREAM BUFFER 28" TREE 100-YR FLOODPLAIN (ZONE AE) (5) UNKNOWN SIZE TREES 24" SYCAMORE NCDOT 10'x70' SIGHT TRIANGLE (TYP) COL D W A T E R T E R R A C E (50' R/ W) â„„R250' â„„R250' 20' FAMILY RECREATIONAL FIELD (110'X170') NEW TREE LINE (TYP) 24" STOP BAR & STOP SIGN 24" STOP BAR & STOP SIGN NCDOT 10'x70' SIGHT TRIANGLE (TYP) 20' 7' GRASS SHOULDER 30' BRIDGE SPAN R30' R30' HEADWALL HEADWALL C2.5 SUBDIVISION PLAN - EASTM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C2.0 - SITE.dwg | Plotted on 12/10/2020 1:32 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83TYPICAL RESIDENTIAL COLLECTOR ROAD N.T.S SITE LEGEND XEXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPERTY LINE FENCE SIGN WHEEL STOP PROPERTY SETBACK EASEMENT LIGHT DUTY ASPHALT HEAVY DUTY ASPHALT CONCRETE SIDEWALKS HEAVY DUTY CONCRETE MATCHLINESHEET C2.2NOTES: 1.ALL PROPOSED ROADS ARE TO BE NCDOT MAINTAINED. 2.ALL LOTS SHALL BE SERVED WITH PRIVATE SEPTIC. 3.ALL LOTS SHALL BE SERVED WITH PUBLIC WATER. 4.SEE SHEET C2.0 FOR SITE DATA. 5.SEE SHEET C2.0 FOR LINE AND CURVE DATA CHARTS. NO SCALE HEAVY DUTY PAVEMENT SECTION DENOTES ASPHALT PAVEMENT ON PLANS 6" NCDOT ABC STONE 1.5" NCDOT S-9.5B 2.5" NCDOT I-19.0B PAVEMENT SECTIONS RECOMMENDED/ ARE BASED ON THE GEOTECH REPORT PREPARED BY FROEHLING & ROBERTSON, INC. DATED APRIL 14, 2020. 6" COMPACTED SUBGRADE (100% ASTM D698) FLOODPLAIN OHPOHPOHPXFORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTYELLIPTICAL CMP 9.5'x6' INV.: 744.27' ELLIPTICAL CMP 9.5'x6' INV.: 743.95' 18"CMP INV.: 742.89' 18"CMP INV.: 742.40' 15"RCP INV.: 737.78' ELLIPTICAL CMP 11.5'x7' INV.: 728.41' ELLIPTICAL CMP 11.5'x7' INV.: 728.34' 18"CMP INV.: 743.15'18"CMP INV.: 742.00'COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PE/P E/PE/P E/P 760 765 770 775 780 785 790 795 775780785790785 780 795790 800 800802 795 790 785 790795800805810 810812 8 0 5 810815820825 8258 2 5820815810805800795790785780775 770 770775 780 785 790795 800805810 805 800 79 5 803 830831830831830829 828 827 82 5 82 0 81 5 810 80 5 800 795 790 7 9 5 800805810815820825830832825820815805800800 800 797 795790785780777 776 775 77 4 772775780785786790795800805 810 80 5 810 812 814 815 810 805 765760 760765770768765761 7657707 7 0 7 6 5 7647657707717707687 6 5 7 6 0 76 2 775770 7 7 5 77677 0 7 7 5 7 7 4 77375576076577076575575375575375 2 7507467 4 8 768765 760 766767755750 745 740 735 73573774 0 734 728 739740735735745740750740745752745750750745747745748747742745748747740740741754748751743738 760755754775780 7857807 7 0 76 9 7 7 5 795775775770765775 780 785 770OHP OHPOHPOHPOHPOHP750750750750 770770770100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) 7 5 0 7 7 0 750 TREE EDGE (TYP) BOATHOUSE WAY (50' PUBLIC R/W) BOATHOUSE WAY (50' PUBLIC R/W) BRIGHT WATER LANE (50' PUBLIC R/W) COLD WATER TERRACE (50' PUBLIC R/W) COLD WATER TERRACE (50' PUBLIC R/W) 8''W 8''W8''W 8''W 8'' W 8''W 8''W 8''W8''W 6''W 8''W 8''W8''W8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W8''W8''W8''W8'' W 8''W 8''W 8''W 8''W 8''WEXISTING 8" WATERMAIN C3.0 OVERALL GRADING AND DRAINAGE PLANM. MARTIN M. MARTIN R. RINGLER 1" = 150' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSS:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin0 300' SCALE 1"=150' 150'NAD 83TYPICAL RESIDENTIAL COLLECTOR ROAD N.T.S C3.1 C3.2 C3.3 C3.4 C3.5 GRADING AND DRAINAGE LEGEND PROPOSED CONTOUR EXISTING CONTOUR800 CATCH BASIN PROPOSED STORM SEWER STORM CLEANOUT 800 TC 349.00'TOP OF CURB ELEVATION SG 349.00'PROPOSED SPOT ELEVATION STORM MANHOLE NYOPLAST INLET RIP RAP EXISTING STORM SEWER PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W EP 349.00'EDGE OF PAVEMENT ELEVATION D FLOOD PLAIN POTENTIALLY JURISDICTIONAL TRIBUTARY N 56° 1 0' 5 9 " E 199.9 6' PIN: 6990-15-7869.00 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG JURISDICTIONAL WETLAND 760 765 770 775 780 785 790 795 775780785790785 780 795 790 800 800802 795 790 785 790795800805810 810812 8 0 5 810815820825 8 2 5820815810805800795790785 780775 770 770775 780 785 790795 800805810 805 800 79 5 803 828 827 82 5 8 2 0 81 5 810 80 5 7 9 5 800805810815820825830832BENT 1/2"IPF 750750750750 77077077040,938 SF 40,146 SF 62,184 SF 40,230 SF 40,186 SF 40,371 SF 40,660 SF 48,425 SF 1 2 3 4 5 6 7 8 10** 11 12 13 14 15 16 38 55 47,182 SF 54 42,032 SF 45,118 SF 40,060 SF 40,258 SF 40,915 SF 40,194 SF 60,045 SF 47,703 SF 40,554 SF 44,806 SF 56 9 6A 28,253 SF 20A 20,229 SF COLDWATER TERRACE(50' R/W) BRIGHT WATER LANE (50' R/W) COLD W A T E R T E R R A C E (50' R/ W )BOATHOUSE WAY (50' R/W) (DESIGNATED OPEN SPACE) (DESIGNATED OPEN SPACE) 49,262 SF 25 27 26 28 30 2978 0 785 7907 9 5 800805810815820825781 782 783 784 7 8 6 7 8 7 7 8 8 7897917927937947 9 6 797798799801802803804806807808809811812813814816817818819821822823824805 810 81 5 82 0 825 802 803 804 806 807 808 809 811 812 81 3 81 4 81 6 81 7 81 8 81 9 82 1 82 2 82 3 824 826 827 828 829 8297857 9 0 795 7867877887897 9 1 79 2 793 794 796 797 RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" EP 800.38 EP 800.38 EP 800.11 EP 800.11 EP 800.11 EP 799.70 EP 800.18 RIPRAP OUTLET PROTECTION 8' L X 3.75' W X 7" THICKNESS D50 = 3" 59 LF 15" RCP INV IN: 794.00 INV OUT: 793.00 TW: 799.00 BW: 793.00 TW: 800.48 BW: 794.00 TW: 800.00 BW: 794.00 TW: 838.00 BW: 838.00 TW: 800.16 BW: 796.00 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 6''W 6''W 6''W2''W 2'' W 8' 'W 8''W 8''W 8''W 8''W8''W8''W 8''W 8''WSTORM STRUCTURE TABLE STRUCTURE # 25 27 28 30 TOP 782.97 779.41 777.53 774.87 STRUCTURE HEIGHT 5.33' ???' 4.70' 3.75' DESCRIPTION NCDOT STD. 840.15 BRICK DROP INLET FLARED-END SECTION NCDOT STD. 840.15 BRICK DROP INLET FLARED-END SECTION N/A N/A STORM PIPE TABLE PIPE # 26 29 DIA 24" 24" FROM - TO 25 - 27 28 - 30 UPSTREAM INVERT 777.64 772.83 DOWNSTREAM INVERT 777.16 772.62 SLOPE 0.50% 1.00% LENGTH 94.84 LF 20.86 LF DESCRIPTION 24 inch RCP 24 inch RCP C3.1 GRADING AND DRAINAGE PLAN - NWM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C3.2MATCHLINE SHEET C3.3 GRADING AND DRAINAGE LEGEND PROPOSED CONTOUR EXISTING CONTOUR800 CATCH BASIN PROPOSED STORM SEWER STORM CLEANOUT 800 TC 349.00'TOP OF CURB ELEVATION SG 349.00'PROPOSED SPOT ELEVATION STORM MANHOLE NYOPLAST INLET RIP RAP EXISTING STORM SEWER PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W EP 349.00'EDGE OF PAVEMENT ELEVATION D X X X X XXXFORSYTH COUNTYGUILFORD COUNTYPIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 820825 8258 2 5 830831830831830829 828 827 82 5 82 0 830832825820815805800800 800 797 795790785780777 776 775 77 4 772775780785786790795800805 810 80 5 810 812 814 815 810 805 765760 760765770768765CMNF CMNF S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'X X28" TREE 40,083 SF 40,313 SF 30 38 39 40 40,168 SF 54 40,289 SF 45,590 SF 48,553 SF 40,387 SF 40,923 SF 43,399 SF 42,032 SF 4645 44 43 42 41 40,258 SF 29 40,111 SF 40,407 SF 41,463 SF 40,174 SF 41,219 SF 46,281 SF 53 52 51 50 49 48 47 40,427 SF COLD W A T E R T E R R A C E (50' R/ W ) COLD W A T E R T E R R A C E (50' R/ W )BOATHOUSE WAY(50' R/W)24" CULVERT C7 C9 C8C4 C6 770775780785790795800805810815820820825825 767768769771772773774776777778779781782783784786787788789791792793794796797798799801802803804806807808809811812813 814 816817818818819819821821822822823823824824826826827827 775825 830 835 774824 826 827 82 7 827828 828828 829 829829 831 832 833 834 836 837 838 839 C5 8''W 8''W8''W 8''W 8''W 8''W8''W 8''W 8''W 8'' W 8''W 8''W 8''W 8''W 8''W 8''W 8''W8''W8''W8''W8''W8''W 8''W8''WSTORM STRUCTURE TABLE STRUCTURE # C4 C6 C7 C9 TOP 765.33 762.62 811.25 808.40 DESCRIPTION FLARED-END SECTION FLARED-END SECTION FLARED-END SECTION FLARED-END SECTION STORM PIPE TABLE PIPE # C5 C8 DIA 36" 24" FROM - TO C4 - C6 C7 - C9 UPSTREAM INVERT 762.00 809.00 DOWNSTREAM INVERT 759.29 806.15 SLOPE 2.70% 2.51% LENGTH 100.25 LF 113.47 LF DESCRIPTION 36 inch RCP 24 inch RCP C3.2 GRADING AND DRAINAGE PLAN - NEM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83TYPICAL RESIDENTIAL COLLECTOR ROAD N.T.S MATCHLINESHEET C3.1MATCHLINE SHEET C3.4 GRADING AND DRAINAGE LEGEND PROPOSED CONTOUR EXISTING CONTOUR800 CATCH BASIN PROPOSED STORM SEWER STORM CLEANOUT 800 TC 349.00'TOP OF CURB ELEVATION SG 349.00'PROPOSED SPOT ELEVATION STORM MANHOLE NYOPLAST INLET RIP RAP EXISTING STORM SEWER PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W EP 349.00'EDGE OF PAVEMENT ELEVATION D SHEET C3.5MATCHLINE PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: 8 2 0 81 5 810 80 5 800 795 790 7 9 5 8007 7 0 76 9775775770765775 780 785 750 7 5 0 7 7 0 69,741 SF 86,073 SF 56,364 SF 40,230 SF 10**16 17 37 38 42,032 SF 44,535 SF 60,045 SF 18 19 20 47,703 SF 42,587 SF 18 16 16B 20 17 19 16A790 790 795 800 805 810 791791792793 794 796 797 798 799 801 802 803 804 806 807 808 809 811 812 81 3 8''W8''W8' 'W 8' 'W 8''W STORM STRUCTURE TABLE STRUCTURE # 16B 16 18 20 TOP 784.75 787.71 787.73 764.62 STRUCTURE HEIGHT ???' 10.27' 16.41' 6.37' DESCRIPTION FLARED-END SECTION NCDOT STD. 840.15 BRICK DROP INLET NCDOT STD. 840.15 BRICK DROP INLET FLARED-END SECTION STORM PIPE TABLE PIPE # 16A 17 19 DIA 24" 24" 24" FROM - TO 16B - 16 16 - 18 18 - 20 UPSTREAM INVERT 782.50 777.44 771.32 DOWNSTREAM INVERT 777.54 771.42 762.37 SLOPE 10.56% 13.00% 13.00% LENGTH 47.00 LF 46.31 LF 68.88 LF DESCRIPTION 24 inch RCP 24 inch RCP 24 inch RCP N/A N/A C3.3 GRADING AND DRAINAGE PLAN - SWM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C3.4SHEET C3.1 MATCHLINE GRADING AND DRAINAGE LEGEND PROPOSED CONTOUR EXISTING CONTOUR800 CATCH BASIN PROPOSED STORM SEWER STORM CLEANOUT 800 TC 349.00'TOP OF CURB ELEVATION SG 349.00'PROPOSED SPOT ELEVATION STORM MANHOLE NYOPLAST INLET RIP RAP EXISTING STORM SEWER PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W EP 349.00'EDGE OF PAVEMENT ELEVATION D DEED LINES 87°40'37" W 1483.80'S 00°22'16" W113.21'CENTER OF ABANDONED RAILROAD BED FORSYTH COUNTYGUILFORD COUNTYPIN: 6990-34-9796 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG 82 0 775 77 4 772770768765761 7657707 7 0 7 6 5 764 7657707717707687 6 5 7 6 0 76 2 775770 7 7 5 77677 0 7 7 5 7 7 4 773760755754775780 785 7807 7 0 76 9 7 7 5 79577577020" TREE 750 TREE EDGE (TYP) 57,166 SF 41,417 SF 41,010 SF40,533 SF 54,596 SF 42,314 SF 41,544 SF 40,206 SF 23 24 26 30 31 28 33 34 35 36 37 38 42,032 SF 44,535 SF 40,100 SF 43,975 SF 42,035 SF 42,724 SF 40,049 SF 40,260 SF 40,002 SF 20 22 25 21 27 42,587 SF 32 BOATHOUSE WAY (50' R/W) 16B 13 11 11B 15 121411A6 8 10 797 7 5 77 5 7757757807857907 7 1 771 772 7 7 2772 772773773773773 774774774 774776777778779781782783784786787788789791791 79 2 792 RIPRAP OUTLET PROTECTION 20' L X 9' W X 16" THICKNESS D50 = 7" RIPRAP OUTLET PROTECTION 8' L X 6' W X 7" THICKNESS D50 = 3" 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W8''WSTORM STRUCTURE TABLE STRUCTURE # 6 8 10 11 11B 13 15 TOP 769.92 769.48 767.75 768.55 765.93 768.55 758.33 STRUCTURE HEIGHT 3.75' 3.85' 6.66' 6.35' ???' 10.66' 6.54' DESCRIPTION NCDOT STD. 840.15 BRICK DROP INLET NCDOT STD. 840.15 BRICK DROP INLET FLARED-END SECTION NCDOT STD. 840.15 BRICK DROP INLET FLARED-END SECTION NCDOT STD. 840.15 BRICK DROP INLET FLARED-END SECTION STORM PIPE TABLE PIPE # 7 9 11A 12 14 DIA 24" 24" 36" 36" 36" FROM - TO 6 - 8 8 - 10 11B - 11 11 - 13 13 - 15 UPSTREAM INVERT 766.17 765.63 762.59 762.20 757.90 DOWNSTREAM INVERT 765.73 765.50 762.30 758.00 755.00 SLOPE 1.00% 1.00% 1.10% 9.50% 10.00% LENGTH 44.22 LF 12.99 LF 26.53 LF 44.22 LF 28.97 LF DESCRIPTION 24 inch RCP 24 inch RCP 36 inch RCP 36 inch RCP 36 inch RCP N/A N/A N/A C3.4 GRADING AND DRAINAGE PLAN - SEM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C3.2SHEET C3.2 MATCHLINE GRADING AND DRAINAGE LEGEND PROPOSED CONTOUR EXISTING CONTOUR800 CATCH BASIN PROPOSED STORM SEWER STORM CLEANOUT 800 TC 349.00'TOP OF CURB ELEVATION SG 349.00'PROPOSED SPOT ELEVATION STORM MANHOLE NYOPLAST INLET RIP RAP EXISTING STORM SEWER PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W EP 349.00'EDGE OF PAVEMENT ELEVATION D X X OHPOHPOHPOHPOHPOHPOHPD.B. 7305 - PG. 2125 BILLY R. MOORE ROBERT N. OGLESBY D.B. 3524 - PG. 1476 ( P.B. 103 - PG. 98 ) ( FIRST TRACT )XXX241.95'129.37'248.07' 349.82' N 88°33'53" E ( 1027.80' ) 26.72' 31.87'S 09°08'49" W808.34'N 88°33'53" E 31.87' ± 21.276 ACRES CONCRETE MONUMENT ELLIPTICAL CMP 9.5'x6' INV.: 744.27' ELLIPTICAL CMP 9.5'x6' INV.: 743.95' 18"CMP INV.: 742.89' 18"CMP INV.: 742.40' 15"RCP INV.: 737.78' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PBARBED WIRE FENCE ENCROACHES 20' UTILITY EASEMENT760 76076576875576076577076575575375575375 2 7507467 4 8 745747740740741 754748751 743738 1/2"IPF CMNF CMNF N01°17'26"E243.18'N88°30'30"E 380.47'OHPX XX28" TREE 100-YR FLOODPLAIN (ZONE AE) (5) UNKNOWN SIZE TREES COL D W A T E R T E R R A C E (50' R/ W) 7' X 5'-1" CORRUGATED METAL ARCHED PIPE C1 C3 C2C4 C6 STORM STRUCTURE TABLE STRUCTURE # C1 C3 C7 C9 TOP 750.88 750.52 811.25 808.40 STRUCTURE HEIGHT ???' ???' ???' ???' DESCRIPTION NCDOT 838.80 CONC. ENDWALL NCDOT 838.80 CONC. ENDWALL FLARED-END SECTION FLARED-END SECTION STORM PIPE TABLE PIPE # C2 C8 DIA 83" 24" FROM - TO C1 - C3 C7 - C9 UPSTREAM INVERT 746.26 809.00 DOWNSTREAM INVERT 745.90 806.15 SLOPE 1.00% 2.51% LENGTH 35.95 LF 113.47 LF DESCRIPTION 83 x 53 inch Concrete Horizontal Elliptical Culvert 24 inch RCP 7' X 5'1" CORRUGATED METAL ARCHED PIPE755760 765770754 7567577587597617 6 2 763764766767768769771772N/A N/A RIPRAP OUTLET PROTECTION 20' L X 9' W X 16" THICKNESS D50 = 7" VAR.C5 N/A N/A 8''W 8''W 8''W 8''W8''W8''W 8''W8''W8''W8''WC3.5 GRADING AND DRAINAGE PLAN - EASTM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.0 - GRAD.dwg | Plotted on 12/10/2020 1:33 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83TYPICAL RESIDENTIAL COLLECTOR ROAD N.T.S MATCHLINESHEET C3.2GRADING AND DRAINAGE LEGEND PROPOSED CONTOUR EXISTING CONTOUR800 CATCH BASIN PROPOSED STORM SEWER STORM CLEANOUT 800 TC 349.00'TOP OF CURB ELEVATION SG 349.00'PROPOSED SPOT ELEVATION STORM MANHOLE NYOPLAST INLET RIP RAP EXISTING STORM SEWER PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W EP 349.00'EDGE OF PAVEMENT ELEVATION D NOTE: CONTRACTOR MAY SUBSTITUTE CONCRETE ARCH PIPE FOR CMP ARCH PIPE. CONTRACTOR REQUIRED TO SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL. DEED LINE60'R/WR/WOHPOHPOHPXFORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTY20' UTILITY EASEMENTOHPOHPOHP100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) 24" SYCAMORE DEED LINE60'R/WR/WOHPOHPOHPXFORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTY20' UTILITY EASEMENTOHPOHPOHP100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) 24" SYCAMORE EP 800.38 EP 800.38 EP 800.11 EP 800.11 EP 800.11 EP 799.70 EP 800.18TW: 799.00 BW: 793.00 TW: 800.48 BW: 794.00 TW: 800.00 BW: 794.00 TW: 838.00 BW: 838.00 TW: 800.16 BW: 796.00 ELLIPTICAL CMP 9.5'X6'INV: 744.27 INLET 28 DRAINAGE AREA = 3.65 AC Q10 = 12.23 CFS Q25 = 13.46 CFS INLET 25 DRAINAGE AREA = 1.10 AC Q10 = 3.98 CFS Q25 = 4.38 CFS INLET 16B DRAINAGE AREA = 3.67 AC Q10 = 14.74 CFS Q25 = 16.23 CFS INLET 11B DRAINAGE AREA = 6.26 AC Q10 = 30.27 CFS Q25 = 33.44 CFS INLET C7 DRAINAGE AREA = 3.13 AC Q10 = 11.42 CFS Q25 = 12.57 CFS INLET 16 DRAINAGE AREA = 0.72 AC Q10 = 2.57 CFS Q25 = 2.83 CFS INLET 18 DRAINAGE AREA = 0.58 AC Q10 = 2.24 CFS Q25 = 2.47 CFS INLET 11 DRAINAGE AREA = 4.01 AC Q10 = 15.64 CFS Q25 = 17.22 CFS INLET 13 DRAINAGE AREA = 0.53 AC Q10 = 2.04 CFS Q25 = 2.24 CFS INLET C4 DRAINAGE AREA = 15.84 AC Q10 = 40.46 CFS Q25 = 44.55 CFS INLET C1 DRAINAGE AREA = 95.07 AC Q10(TR55 METHOD) = 102.71 CFS Q25(TR55 METHOD) = 158.65 CFS INLET 6 DRAINAGE AREA = 4.90 AC Q10 = 19.59 CFS Q25 = 21.57 CFS INLET 8 DRAINAGE AREA = 0.39 AC Q10 = 1.53 CFS Q25 = 1.69 CFS C3.6 POST-DEVELOPMENT DRIANAGE MAPM. MARTIN M. MARTIN R. RINGLER 1" = 150' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C3.6 - DRAN.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTS0 300' SCALE 1"=150' 150'NAD 83 DEED LINE60'R/WR/WOHPOHPOHPXCOLDWATER ROADFORSYTH COUNTYGUILFORD COUNTYFORSYTH COUNTYGUILFORD COUNTYREIDSVILLE ROAD (US H I G H W A Y 1 5 8 )COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PE/P E/PE/P E/P20' UTILITY EASEMENTOHP OHPOHPOHPOHPOHP20" TREE 28" TREE 100-YR FLOODPLAIN (ZONE AE) 100-YR FLOODPLAIN (ZONE AE) TREE EDGE (TYP) (5) UNKNOWN SIZE TREES BOATHOUSE WAY (50' PUBLIC R/W) BOATHOUSE WAY (50' PUBLIC R/W) BRIGHT WATER LANE (50' PUBLIC R/W) COLD WATER TERRACE (50' PUBLIC R/W) COLD WATER TERRACE (50' PUBLIC R/W)COLDWATER TERRACE(50' R/W)BRIGHT WATER LANE (50' R/W) COLD W A T E R T E R R A C E (50' R/ W ) COLD W A T E R T E R R A C E (50' R/ W ) BOATHOUSE WAY (50' R/W)BOATHOUSE WAY(50' R/W)BOATHOUSE WAY (50' R/W) COL D W A T E R T E R R A C E (50' R/ W)8''W 8''W8''W 8''W 8'' W 8''W 8''W 8''W8''W 6''W 8''W 8''W8''W8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W8''W8''W8''W8'' W 8''W 8''W 8''W 8''W 8''WEXISTING 8" WATERMAIN C4.0 OVERALL UTILITY PLANM. MARTIN M. MARTIN R. RINGLER 1" = 150' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSS:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin0 300' SCALE 1"=150' 150'NAD 83C4.1 C4.2 C4.3 C4.4 C4.5 UTILITY LEGEND PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W PROPOSED UNDERGROUND POWERUGP EXISTING UNDERGROUND POWERUGP PROPOSED OVERHEAD POWEROHP EXISTING OVERHEAD POWEROHP EXISTING OVERHEAD COMMUNICATIONOFO UFO EXISTING UNDERGROUND COMMUNICATION G EXISTING NATURAL GAS UTILITY EASEMENT PROPOSED POWER STRUCTURE EXISTING POWER STRUCTURE PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED BEND PROPOSED TEE PROPOSED GATE VALVE PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY SANITARY MANHOLE SANITARY CLEANOUT S POTENTIALLY JURISDICTIONAL TRIBUTARY N 56° 1 0' 5 9 " E 199.9 6' PIN: 6990-15-7869.00 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG PIN: 6990-27-4148.00 N/F: DUKE POWER COMPANY ZONING:AG JURISDICTIONAL WETLAND BENT 1/2"IPF COLDWATER TERRACE(50' R/W) BRIGHT WATER LANE (50' R/W) COLD W A T E R T E R R A C E (50' R/ W )BOATHOUSE WAY (50' R/W) 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 6''W 6''W 6''W2''W 2'' W 8' 'W 8''W 8''W 8''W 8''W8''W8''W 8''W 8''WFIRE HYDRANT SPACED ± 500' 6" X 2" REDUCER 6" PVC PUBLIC WATERLINE 2" PVC WATERLINE 8" X 6" TEE W/ (2) 8" VALVES 8" TEE W/ (2) 8" VALVES 3/4" WATER SERVICE AND METER BOX (TYP) FIRE HYDRANT SPACED ± 500' 3/4" WATER SERVICE AND METER BOX (TYP) BLOW-OFF ASSEMBLY(TYP) C4.1 UTILITY PLAN - NWM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C4.2MATCHLINE SHEET C4.3 UTILITY LEGEND PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W PROPOSED UNDERGROUND POWERUGP EXISTING UNDERGROUND POWERUGP PROPOSED OVERHEAD POWEROHP EXISTING OVERHEAD POWEROHP EXISTING OVERHEAD COMMUNICATIONOFO UFO EXISTING UNDERGROUND COMMUNICATION G EXISTING NATURAL GAS UTILITY EASEMENT PROPOSED POWER STRUCTURE EXISTING POWER STRUCTURE PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED BEND PROPOSED TEE PROPOSED GATE VALVE PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY SANITARY MANHOLE SANITARY CLEANOUT S X X X X XXXFORSYTH COUNTYGUILFORD COUNTYPIN: 6990-36-5854 N/F: LOUZIEL C. SCALES DB 792 PG 349 ZONING: AG PB 12 PG 76 BARBED WIRE FENCE ENCROACHES BARBED WIRE FENCE ENCROACHES CMNF CMNF S76°1 3 ' 5 6 " E 2,215. 4 0 'N01°17'26"E243.18'X X28" TREE COLD W A T E R T E R R A C E (50' R/ W ) COLD W A T E R T E R R A C E (50' R/ W )BOATHOUSE WAY(50' R/W)8''W 8''W8''W 8''W 8''W 8''W8''W 8''W 8''W 8'' W 8''W 8''W 8''W 8''W 8''W 8''W 8''W8''W8''W8''W8''W8''W 8''W8''W8" CROSS W/ (3) 8" VALVES 8" PLUG AT PROPERTY LINE W/ 8" VALVE 8" AIR-RELEASE VALVE 3/4" WATER SERVICE AND METER BOX (TYP) 8" TEE W/ (2) 8" VALVES FIRE HYDRANT SPACED ± 500' FIRE HYDRANT ASSEMBLY 3/4" WATER SERVICE AND METER BOX (TYP) CAP 8" WATERMAIN FOR END OF LINE PHASE 1 - REMOVE CAP AND CONNECT TO EXISTING WATERMAIN FOR PHASE 2 C4.2 UTILITY PLAN - NEM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C4.1MATCHLINE SHEET C4.4 UTILITY LEGEND PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W PROPOSED UNDERGROUND POWERUGP EXISTING UNDERGROUND POWERUGP PROPOSED OVERHEAD POWEROHP EXISTING OVERHEAD POWEROHP EXISTING OVERHEAD COMMUNICATIONOFO UFO EXISTING UNDERGROUND COMMUNICATION G EXISTING NATURAL GAS UTILITY EASEMENT PROPOSED POWER STRUCTURE EXISTING POWER STRUCTURE PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED BEND PROPOSED TEE PROPOSED GATE VALVE PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY SANITARY MANHOLE SANITARY CLEANOUT S PIN: 6990-24-0998.00 N/F: DUKE POWER COMPANY DB 1005 PG 453 ZONING: B78''W8''W8' 'W 8' 'W 8''W C4.3 UTILITY PLAN - SWM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C4.4SHEET C4.1 MATCHLINE UTILITY LEGEND PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W PROPOSED UNDERGROUND POWERUGP EXISTING UNDERGROUND POWERUGP PROPOSED OVERHEAD POWEROHP EXISTING OVERHEAD POWEROHP EXISTING OVERHEAD COMMUNICATIONOFO UFO EXISTING UNDERGROUND COMMUNICATION G EXISTING NATURAL GAS UTILITY EASEMENT PROPOSED POWER STRUCTURE EXISTING POWER STRUCTURE PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED BEND PROPOSED TEE PROPOSED GATE VALVE PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY SANITARY MANHOLE SANITARY CLEANOUT S S 87°40'37" W 1483.80'S 00°22'16" W113.21'FORSYTH COUNTYGUILFORD COUNTYPIN: 6990-34-9796 N/F: DUKE POWER COMPANY DB 1005 PG 397 ZONING: AG B9 B8 20" TREE TREE EDGE (TYP) BOATHOUSE WAY (50' R/W) 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W8''W8" PVC PUBLIC WATER MAIN FIRE HYDRANT SPACED ± 500' 3/4" WATER SERVICE AND METER BOX (TYP) CAP 8" WATERMAIN FOR END OF LINE PHASE 1 - REMOVE CAP AND CONNECT TO EXISTING WATERMAIN FOR PHASE 2 C4.4 UTILITY PLAN - SEM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C4.3SHEET C4.2 MATCHLINE UTILITY LEGEND PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W PROPOSED UNDERGROUND POWERUGP EXISTING UNDERGROUND POWERUGP PROPOSED OVERHEAD POWEROHP EXISTING OVERHEAD POWEROHP EXISTING OVERHEAD COMMUNICATIONOFO UFO EXISTING UNDERGROUND COMMUNICATION G EXISTING NATURAL GAS UTILITY EASEMENT PROPOSED POWER STRUCTURE EXISTING POWER STRUCTURE PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED BEND PROPOSED TEE PROPOSED GATE VALVE PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY SANITARY MANHOLE SANITARY CLEANOUT S X X OHPOHPOHPOHPOHPOHPOHPXXXPOTENTIALLY JURISDICTIONAL WETLAND JURISDICTIONAL TRIBUTARIES 241.95'129.37'248.07' 349.82' N 88°33'53" E ( 1027.80' ) 26.72' 31.87'S 09°08'49" W808.34'N 88°33'53" E 31.87' PIN: 6990-46-8354.00 N/F: CHRISTOPHER S. ANDRESS AND SPOUSE, AMY K. ANDRESS DB 7958 PG 2377 ZONING: AG PB 92 PG 82 COLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAYE/PE/PBARBED WIRE FENCE ENCROACHES 1/2"IPF CMNF CMNF N01°17'26"E243.18'N88°30'30"E 380.47'OHPX XX30' STREAM BUFFER 28" TREE 100-YR FLOODPLAIN (ZONE AE) (5) UNKNOWN SIZE TREES COL D W A T E R T E R R A C E (50' R/ W) 8''W 8''W 8''W 8''W8''W8''W 8''W8''W8''W8''W8" PVC PUBLIC WATER MAIN 8" TEE W/ (2) 8" VALVES 8" PVC PUBLIC WATER MAIN AIR RELEASE VALVE 3/4" IRRIGATION SERVICE & (2) 2" CONDUIT C4.5 UTILITY PLAN - EASTM. MARTIN M. MARTIN R. RINGLER 1" = 50' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C4.0 - UTIL.dwg | Plotted on 12/10/2020 1:34 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSSCALE 1"=50' 100'50'0 NAD 83MATCHLINESHEET C4.2UTILITY LEGEND PROPOSED SANITARY SEWER EXISTING SANITARY SEWER SAN SAN PROPOSED WATERMAIN EXISTING WATERMAIN W W PROPOSED UNDERGROUND POWERUGP EXISTING UNDERGROUND POWERUGP PROPOSED OVERHEAD POWEROHP EXISTING OVERHEAD POWEROHP EXISTING OVERHEAD COMMUNICATIONOFO UFO EXISTING UNDERGROUND COMMUNICATION G EXISTING NATURAL GAS UTILITY EASEMENT PROPOSED POWER STRUCTURE EXISTING POWER STRUCTURE PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED BEND PROPOSED TEE PROPOSED GATE VALVE PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY SANITARY MANHOLE SANITARY CLEANOUT S NOTE: SEE SHEET C5.0 FOR OFF-SITE WATER PLAN AND PROFILES. OHP OHP OHP OHP OHP OHP OHPOHPOHPOHPOHPOHPOHPOHPCOLDWATER DRIVE(SR-2038) DB 6154 PG 190960' PUBLIC RIGHT-OF-WAY755753755753752750746748752745750750745747745 748747742745748747740740741754748751743738OHPOHP OHP OHP OHP OHP OHPX 8''W8''W8''W8''W 8''W 8''W 8''W 8''W 8''W8''W8''W8''W8''W8''W8''W-0+20 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+0 0 8+5 0 9+0 0 9+5 0 10+ 0 0 10+5 0 11+00 11+50 12+00 12+50 8" TEE W/ (2) 8" VALVE FIRE HYDRANT ASSEMBLY (TYP) 8" AIR RELEASE VALVE (TYP) 8" AIR RELEASE VALVE (TYP) HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 OFF-SITE WATER MAIN EXTENSION 735 740 745 750 755 760 765 770 725 730 735 740 745 750 755 760 OFF-SITE WATER MAIN EXTENSION754.2753.0751.4750.0748.4747.1746.7746.1745.7745.7746.0746.7747.6748.0748.0747.4746.7746.1746.3747.2748.5750.1751.2751.0754.16752.98751.36750.04748.44747.14746.73746.10745.66745.66746.02746.71747.62748.00748.00747.43746.72746.15746.27747.17748.50750.08751.15750.990+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY 8" END CAP 8" VALVE 8" TEE WITH ON-SITE WATER MAIN & 8" VALVE VERTICAL BEND TO ACHIEVE MIN. SEPARATION AIR RELEASE VALVE VERTICAL BEND TO ACHIEVE MIN. SEPARATION VERTICAL BEND TO ACHIEVE MIN. SEPARATION 9.5' X 6' ELLIPTICAL CMP 18" CMP 18" CMP 15" RCP AIR RELEASE VALVE 24" MIN. 24" MIN.24" MIN. C5.0 OFF-SITE WATER PLAN/ PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C5.0 - UTILPROF.dwg | Plotted on 12/10/2020 1:35 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSPROFILE SCALE 0 0 40 4 NAD 830 SCALE 1"=40' 80'40'MATCHLINESHEET C5.1SHEET C5.1MATCHLINEH: 1" = 40' V: 1" = 4' 760755750745740735735737740734728739740735735745740750740745752745750747OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP8''W8''W8''W 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W 11+5 0 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+5 0 23+0 0 23+ 5 0 24+ 0 0 24+5 0 FIRE H Y D R A N T ASS E M B L Y ( T Y P) 8" AIR REL E A S E VALVE (TY P ) 735 740 745 750 755 760 765 770 725 730 735 740 745 750 755 760 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 OFF-SITE WATER MAIN EXTENSION 735 740 745 750 755 760 765 770 OFF-SITE WATER MAIN EXTENSION751.0751.0749.7748.3746.8745.5744.0742.3741.1739.9738.8737.5736.9736.7736.3736.1736.0735.8737.2739.1742.1746.1750.2754.7759.6750.99750.95749.69748.28746.81745.48743.96742.30741.09739.91738.80737.53736.88736.65736.33736.08735.97735.81737.16739.05742.12746.07750.18754.75759.6112+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY VERTICAL BEND TO ACHIEVE MIN. SEPARATION 11.5' X 7' ELLIPTICAL CMP 24" MIN. C5.1 OFF-SITE WATER PLAN/ PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C5.0 - UTILPROF.dwg | Plotted on 12/10/2020 1:35 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSPROFILE SCALE 0 0 40 4 NAD 830 SCALE 1"=40' 80'40'MATCHLINESHEET C5.0SHEET C5 .2MATCHLINE MATCHLINESHEET C5.0H: 1" = 40' V: 1" = 4' 7687657607667677558'' W8'' W8'' W8'' W8'' W8'' W23+50 24+00 24+50 25+00 25+23.19 CONNECT TO EXISTING 8" WATER MAIN W/ 8" TEE, (2) 8" VALVES FIRE HYDRANT ASSEMBLY (TYP) 37 LF JACK AND BORE UNDER STREET HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 OFF-SITE WATER MAIN EXTENSION 735 740 745 750 755 760 765 770 735 740 745 750 755 760 765 770 739.1742.1746.1750.2754.7759.6764.9739.05742.12746.07750.18754.75759.61764.9222+00 23+00 24+00 25+00 26+00 26+50 FIRE HYDRANT ASSEMBLY 8" TEE AND (2) 8" VALVES TO CONNECT TO EXISTING WATER MAIN JACK AND BORE UNDER STREET C5.2 OFF-SITE WATER PLAN/ PROFILEM. MARTIN M. MARTIN R. RINGLER H: 1" = 40' V: 1" = 4' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C5.0 - UTILPROF.dwg | Plotted on 12/10/2020 1:35 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSPROFILE SCALE 0 0 40 4 NAD 830 SCALE 1"=40' 80'40'MATCHLINESHEET C5.0MATCHLINESHEET C5.1NOTE: CONTRACTOR TO POTHOLE EXISTING WATER MAIN TO DETERMINE SIZE AND DEPTH PRIOR TO STARTING CONSTRUCTION. HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 COLD WATER TERRACE 770 775 780 785 790 795 800 805 810 815 770 775 780 785 790 795 800 805 810 815 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 COLD WATER TERRACE 780 785 790 795 800 805 810 815 820 825 780 785 790 795 800 805 810 815 820 825 795 800 805 810 815 820 825 830 835 840 783.8788.9792.9795.5798.6802.0801.2796.7793.9790.9790.7796.0798.4797.5796.4794.1797.8803.6808.9813.2815.2814.1813.9816.3783.84788.86792.89795.46798.58802.00801.21796.69793.93790.87790.74795.97798.42797.51796.37794.12797.79803.61808.91813.24815.16814.15813.88816.29-0+50 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 113' VC K = 20.00 A.D. = -5.66% PVI ELEV = 795.21 PVI STA = 6+50.48 HIGH PT STA = 7+07.07 HIGH POINT ELEV = 795.85 BVCS = 5+93.90BVCE = 791.36EVCS = 7+07.07EVCE = 795.85109' VC K = 20.00 A.D. = 5.45% PVI ELEV = 797.13 PVI STA = 8+19.69 LOW POINT STA = 7+65.17 LOW POINT ELEV = 796.51 BVCS = 7+65.17BVCE = 796.51EVCS = 8+74.22EVCE = 800.72121' VC K = 20.00 A.D. = 6.05% PVI ELEV = 785.00 PVI STA = 5+00.15 LOW POINT STA = 4+39.68 LOW POINT ELEV = 784.54 BVCS = 4+39.68BVCE = 784.54EVCS = 5+60.63EVCE = 789.101.00% 1.14% 6.59 % 0.75% 6.79 % CENTERLINE OF STREET "BRIGHT WATER LANE" CENTERLINE OF STREET "BRIGHT WATER LANE" EXISTING GROUND EXISTING GROUND 6" PVC WATERMAIN 2" PVC WATERMAIN TO LOOP AROUND CUL-DE-SAC 6"X2" REDUCER 8"X6" TEE W/ 2 VALVES 2" BLOW-OFF ASSEMBLY FIRE HYDRANT ASSEMBLY 8" TEE W/ VALVE 26 94.84' OF 24" RCP @ 0.50% 12" MIN. FIRE HYDRANT ASSEMBLY0+000+501+001 + 5 0 2+ 0 0 2+50 3+00 3+50 4+00 4+50 0+00 0 + 5 0 1+00 1+502+ 0 0 2+50 3+003+12.860+00 1+00 2+00 3+00 4+00 5+00 6+00 7+ 0 0 COLDW A T E R T E R R A C E (50' R / W ) BR I G H T W A T E R L A N E (50 ' R / W ) 76 5 77 0 77 5 780 785 790 795 780 785 790 785 780 795 790 80 0 800 802 795 790 785 790795800805810 780 775 770 770 775 780 785 790 795 800 805 81 0 8 0 5 8 0 0 795770 25 27 2628 29 40,943 SF 48 , 4 2 0 S F 4 8 1 2 40,747 SF 40,169SF 9 8'' W 8'' W 8''W 8''W 6''W 6''W 6''W 6''W 2'' W 2''W2'' W 8' 'W 8 ' 'W 8'' W 8''W 8''W 8''W 3+504+004+504+90.568+00 9+00 10+00 11+00 COLDWATER TERRACE (50' R/W) 810812 8 0 5 81 0 815825 820815810805800795790785 803800805810 815820797798799801802803804806807808809811812813814816817818819821795 794796 797 800.38 TW: 800 . 4 8 40,371 SF12 13 55 54 40,037 SF 40,051 SF 8''W8''W8''W8''W8''W8''W 8''W8''WC6.0 COLD WATER TERRACE PLAN & PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:36 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTS0 SCALE 1"=40' 80'40'NAD 83MATCHLINESHEET C6.1PROFILE SCALE 0 0 40 4 MATCHLINESHEET C6.10 SCALE 1"=40' 80'40'NAD 83MATCHLINETHIS SHEETMATCHLINETHIS SHEETH: 1" = 40' V: 1" = 4' 780 785 790 795 800 805 810 815 820 825 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 COLD WATER TERRACE 795 800 805 810 815 820 825 830 835 840 795 800 805 810 815 820 825 830 835 840 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 COLD WATER TERRACE 770 775 780 785 790 795 800 805 810 815 770 775 780 785 790 795 800 805 810 815 750 755 760 765 770 775 780 785 790 795 COLD WATER TERRACE816.3822.0825.8829.0830.8831.6829.6825.9821.1814.8807.9806.1805.3805.6807.1805.1802.4803.0804.1804.9802.8799.9796.3792.3787.3816.29821.97825.78829.04830.81831.62829.61825.94821.13814.76807.90806.09805.32805.59807.07805.06802.45802.95804.13804.86802.83799.90796.34792.34787.3112+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 237' VC K = 20.00 A.D. = -11.87% PVI ELEV = 831.38 PVI STA = 13+39.46 HIGH PT STA = 13+52.49 HIGH POINT ELEV = 827.89 BVCS = 12+20.72BVCE = 823.55EVCS = 14+58.19EVCE = 825.1066' VC K = 20.00 A.D. = -3.28% PVI ELEV = 813.50 PVI STA = 18+21.47 HIGH PT STA = 17+88.67 HIGH POINT ELEV = 814.00 BVCS = 17+88.67BVCE = 814.00EVCS = 18+54.27EVCE = 811.9275' VC K = 20.00 A.D. = 3.75% PVI ELEV = 816.60 PVI STA = 16+18.97 LOW POINT STA = 16+56.50 LOW POINT ELEV = 816.03 BVCS = 15+81.45BVCE = 818.59EVCS = 16+56.50EVCE = 816.03-5. 2 8 % -1.53% -4. 8 1 % CENTERLINE OF STREET "BOATHOUSE WAY" EXISTING GROUND C8 113.47' OF 24" RCP @ 2.51% 24" MIN. 3' 8" PVC WATERMAIN 8" PVC WATERMAIN 8" CROSS W/ VALVES 8" AIR RELEASE VALVE FIRE HYDRANT ASSEMBLY FIRE HYDRANT ASSEMBLY4+005+006+0012+00 13+00 14+00 15+00 16+00 17+00 18+0 0 19+00 20+00 21+00 22+00 23+00 COLDWATER TERRACE (50' R/W) COLDWATER TERRACE (50' R/W)BOATHOUSE WAY(50' R/W)PIN: 699 0 - 3 5 - 6 6 5 7 N/F: STU A R T W A Y N E P A R R I S H A N D815820825825830831830825820815805800800800 797 795790785790795800805810 805810812 814 815 810 805 C7 C9C8 790795800805810815820820825825 787788789791792793794796797798799801802803804806807808809811812813814 816817817818818819819821821822822823823824824826826827827830 835 827 8 2 7 8 2 8 828 829 831 832 833 834 836 40,084 SF40,371 SF 13 40,379 SF 46 41 40,500 SF 40,265 SF 41,245 SF 40,189 SF 41,087 SF 53 52 51 50 49 48 40,016 SF20A20,579 SF8''W8''W 8''W 8''W 8''W8''W 8''W 8''W 8''W8''W8''W8''W8''W8''W8''W8''W 8''W8''W8''W8''WC6.1 COLD WATER TERRACE PLAN & PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:36 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSMATCHLINESHEET C6.2MATCHLINESHEET C6.0PROFILE SCALE 0 0 40 4 0 SCALE 1"=40' 80'40'NAD 83MATCHLINESHEET C6.2H: 1" = 40' V: 1" = 4' 770 775 780 785 790 795 800 805 810 815 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 COLD WATER TERRACE 750 755 760 765 770 775 780 785 790 795 750 755 760 765 770 775 780 785 790 795 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 COLD WATER TERRACE 740 745 750 755 760 765 770 775 780 785 740 745 750 755 760 765 770 775 780 785 799.9796.3792.3787.3783.5782.2779.8775.8769.8763.1760.8762.6765.5766.4764.7762.4760.0758.4756.8755.6754.4752.6753.0754.3799.90796.34792.34787.31783.53782.23779.79775.78769.77763.09760.84762.60765.51766.40764.75762.39760.04758.40756.79755.63754.36752.62753.00754.3222+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 34+50 40' VC K = 20.00 A.D. = -2.00% PVI ELEV = 754.53 PVI STA = 32+86.80 HIGH PT STA = 32+86.80 HIGH POINT ELEV = 754.43 BVCS = 32+66.80BVCE = 754.33EVCS = 33+06.80EVCE = 754.3346' VC K = 20.00 A.D. = 2.28% PVI ELEV = 762.56 PVI STA = 28+80.01 LOW POINT STA = 29+02.86 LOW POINT ELEV = 761.99 BVCS = 28+57.17BVCE = 763.66EVCS = 29+02.86EVCE = 761.9971' VC K = 20.00 A.D. = 3.53% PVI ELEV = 753.89 PVI STA = 32+23.01 LOW POINT STA = 32+38.29 LOW POINT ELEV = 754.15 BVCS = 31+87.73BVCE = 754.78EVCS = 32+58.29EVCE = 754.25-4. 8 1 % -2.53 % 1.00%-1.00% CENTERLINE OF STREET "BOATHOUSE WAY" EXISTING GROUND EXISTING GROUND C5 100.25' OF 36" RCP @ 2.70% STREAM CROSSING SPAN 30' CONNECT TO PROPOSED 8" WATERMAIN VERTICAL BEND TO MAINTAIN SEPARATION 8" PVC WATERMAIN 4' TYP (3' MIN.) 8" TEE W/ VALVE 3.5' ±30 LF 16" STEEL ENCASEMENT C2: 36 LF OF 7'"X5'-1" CMP @ 1.00% BURIED 1' UNDER EXISTING SURFACE 24"31+0031+93.2922+00 23+00 24+00 25+00 26+00 COLDWATER TERRACE (50' R/W)795790785780777776775780785786790795800 7657757807857907957767 7 7 77877978178278378478678778878979179279379440,230 SF46 2941,087 SF 46,117 SF 48 47 8''W 8''W 8''W8''W8''W 8' 'W8' 'W31+93.2926 + 0 0 27+00 28+00 29+00 30+00 31+00 32+00 33 + 0 0 33 + 5 4 . 2 2 COLDWATER TERRACE (50' R/W) X XX OHP OHP OHPXXX COLD W A T E R D R I V E E/PE/P7757807657 6 0760765 755 760765 770 765 755753 755753752750754748 751 743XX XX(5) UNKNOWNSIZE TREES24"SYCAMOREC1 C3 C2C4 C6 75576 0 765770775754756757758759761762 763764766767768769771772773774776777C5 8'' W 8''W 8''W8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''WC6.2 COLD WATER TERRACE PLAN AND PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:36 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSMATCHLINESHEET C6.1PROFILE SCALE 0 0 40 4 0 SCALE 1"=40' 80'40'NAD 830 SCALE 1"=40' 80'40'NAD 83H: 1" = 40' V: 1" = 4'MATCHLINETHIS SHEETMATCHLINETHIS SHEET HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 BOATHOUSE WAY 810 815 820 825 830 835 840 845 850 855 810 815 820 825 830 835 840 845 850 855 770 775 780 785 790 795 800 805 810 815 838.0838.0835.5833.3831.5827.8826.0827.8831.0832.5832.0828.6825.0820.9817.4812.2806.8801.4838.00838.00835.48833.27831.49827.83826.00827.78830.98832.46832.00828.58825.02820.93817.40812.17806.76801.42-0+50 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 234' VC K = 20.00 A.D. = -11.69% PVI ELEV = 832.04 PVI STA = 8+19.99 HIGH PT STA = 7+60.92 HIGH POINT ELEV = 829.50 BVCS = 7+03.11BVCE = 828.66EVCS = 9+36.87EVCE = 821.7646' VC K = 20.00 A.D. = -2.31% PVI ELEV = 837.82 PVI STA = 3+43.35 HIGH PT STA = 3+20.27 HIGH POINT ELEV = 839.01 BVCS = 3+20.27BVCE = 839.01EVCS = 3+66.43EVCE = 836.10253' VC K = 24.42 A.D. = 10.36% PVI ELEV = 823.72 PVI STA = 5+32.15 LOW POINT STA = 5+88.06 LOW POINT ELEV = 826.36 BVCS = 4+05.66BVCE = 833.17EVCS = 6+58.65EVCE = 827.382.89% -5. 1 6 % -7 . 4 7 % -8 . 8 0% INTERSECTION CENTERLINE WITH "COLD WATER TERRACE" OFF-SITE 849.6848.1846.7845.6843.9841.5840.1838.2835.9833.3EXISTING GROUND EXISTING GROUND EXISTING GROUND 8" PLUG AND VALVE FIRE HYDRANT ASSEMBLY 8" CROSS W/ VALVES 8" PVC WATERMAIN FIRE HYDRANT ASSEMBLY 3' MIN. MAIN END CAP FOR PHASE 1 - REMOVE AND CONNECT FOR PHASE 2 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+0 0 9+ 0 0 10 + 0 0 11+00 12+00 11+0012+0013+0014+00COLDWATER TERRACE(50' R/W)BOATHOUSE WAY(50' R/W)BOATHOUSE WAY(50' R/W)810815 820825825825830831830831830829828827825820815810805800805810815820825830832815 820 825 814 816 817 818 819 821 822 823 824 826 827 800805810815820825830835797798799801802803804806807808809811812813814816817818819821822823824826827827827828828828829829829831832833834836837838839 40,371 SF40,660 SF1314 38 39 5443,399 SF 42,028 SF 40,051 SF40,016 SF20A 20,579 SF 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WC6.3 BOATHOUSE WAY PLAN & PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:36 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSPROFILE SCALE 0 0 40 4 0 SCALE 1"=40' 80'40'NAD 83MATCHLINESHEET C6.4SHEET C6.4MATCHLINEH: 1" = 40' V: 1" = 4' 810 815 820 825 830 835 840 845 850 855 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 BOATHOUSE WAY 770 775 780 785 790 795 800 805 810 815 770 775 780 785 790 795 800 805 810 815 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 BOATHOUSE WAY 760 765 770 775 780 785 790 795 800 805 760 765 770 775 780 785 790 795 800 805 745 750 755 760 765 770 775 780 785 790 BOATHOUSE WAY825.0820.9817.4812.2806.8801.4796.7790.8786.5780.6773.9779.6780.6778.8782.2786.2790.9791.9790.6786.6781.0774.7768.0761.1759.3825.02820.93817.40812.17806.76801.42796.67790.76786.53780.64773.90779.60780.56778.80782.15786.17790.90791.89790.60786.58780.97774.69768.02761.07759.329+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00EVCS = 9+36.87EVCE = 821.76159' VC K = 20.00 A.D. = -7.95% PVI ELEV = 793.05 PVI STA = 17+12.39 HIGH PT STA = 16+53.31 HIGH POINT ELEV = 792.34 BVCS = 16+32.93BVCE = 792.24EVCS = 17+91.84EVCE = 787.54196' VC K = 20.00 A.D. = 9.82% PVI ELEV = 788.94 PVI STA = 13+09.82 LOW POINT STA = 13+87.61 LOW POINT ELEV = 789.84 BVCS = 12+11.66BVCE = 797.58EVCS = 14+07.99EVCE = 789.95167' VC K = 20.00 A.D. = 8.33% PVI ELEV = 769.74 PVI STA = 20+48.88 LOW POINT STA = 21+04.12 LOW POINT ELEV = 770.71 BVCS = 19+65.59BVCE = 775.51EVCS = 21+32.171.02% -6 . 9 3 % -8 . 8 0% EXISTING GROUND EXISTING GROUND 17 46.31' OF 24" RCP @ 13.00% 8" PVC WATERMAIN 8" PVC WATERMAIN FIRE HYDRANT ASSEMBLY 3' MIN. FIRE HYDRANT ASSEMBLY 16+00 17+00 18+00 19+00 20+00 21+00 BOATHOUSE WAY 760755754775780 7857807 7 5 79513 11 11B 15 121411A7757807857907 7 17727737747767777787797817827837847867877887897917 9 2792 42,305 SF 41,544 SF 40,192 SF 23 35 36 40,100 SF 43,969 SF 42,094 SF 22 21 8''W 8''W 8''W 8''W 8''W 8''W 8''W9+0010+001 1 + 0 0 12 + 0 0 13+00 14+0 0 15+0016+0017+00BOATHOUSE WAY(50' R/W)825 820 815 810805 800795790795800805810 815 820825 780770 769 775 775775770785 18 16 16B 171916A79 0 790795800805810815 820825 791791792 792792793794796797798799801802803804806807808809811812 813 814 816 817 818 819 821 822 823 824 40,186 SF37 3 8 4 2 , 0 2 8 S F 44,535 SF 20 42,601 SF8''W8''W8''W8''W8''W 8''W 8''W 8''W 8''W8''WC6.4 BOATHOUSE WAY PLAN & PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:36 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSMATCHLINESHEET C6.3PROFILE SCALE 0 0 40 4 0 SCALE 1"=40' 80'40'NAD 83SHEET C6.5MATCHLINESHEET C6.5MATCHLINETHIS SHEETMATCHLINEMATC H LI N E SHEE T C 6. 3 MA T C H L I N E THI S S H E E T 0 SCALE 1"=40' 80'40'NAD 83H: 1" = 40' V: 1" = 4' 760 765 770 775 780 785 790 795 800 805 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 BOATHOUSE WAY 745 750 755 760 765 770 775 780 785 790 745 750 755 760 765 770 775 780 785 790 BOATHOUSE WAY 745 750 755 760 765 770 775 780 785 790 781.0774.7768.0761.1759.3760.4763.7765.3765.3766.4768.6771.5773.5773.3769.6767.4768.6771.9772.8769.7769.1770.6772.5774.1773.7780.97774.69768.02761.07759.32760.36763.75765.34765.26766.37768.65771.51773.48773.32769.56767.35768.62771.87772.83769.67769.10770.64772.50774.11773.7219+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 110' VC K = 20.00 A.D. = -5.51% PVI ELEV = 776.05 PVI STA = 24+99.17 HIGH PT STA = 24+72.16 HIGH POINT ELEV = 775.48 BVCS = 24+44.11BVCE = 775.28EVCS = 25+54.23EVCE = 773.79167' VC K = 20.00 A.D. = 8.33% PVI ELEV = 769.74 PVI STA = 20+48.88 LOW POINT STA = 21+04.12 LOW POINT ELEV = 770.71 BVCS = 19+65.59BVCE = 775.51EVCS = 21+32.17EVCE = 770.91102' VC K = 20.00 A.D. = 5.10% PVI ELEV = 770.79 PVI STA = 26+27.42 LOW POINT STA = 26+58.46 LOW POINT ELEV = 771.20 BVCS = 25+76.39BVCE = 772.88EVCS = 26+78.45EVCE = 771.30-6 . 9 3 % 1.40% -4.1 0 % 1.00% EXISTING GROUND EXISTING GROUND INTERSECTION WATER TERRACE 12 44.22' OF 36" RCP @ 9.50% 7 44.22' OF 24" RCP @ 1.00% 8" PVC WATERMAIN 24" MIN. FIRE HYDRANT ASSEMBLY VERTICAL BEND TO ACHIEVE MIN. SEPARATION FIRE HYDRANT ASSEMBLY TERRACE WATERMAIN 8" PVC WATERMAIN 8" DUCTILE IRON FIRE HYDRANT ASSEMBLY MAIN END CAP FOR PHASE 1 - REMOVE AND CONNECT FOR PHASE 2 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 BOATHOUSE WAY (50' R/W) 7657707717707687 6 5 7 6 0 76 2 77577 0 7 7 5 77677 0 76075575477578013 11 11B 15 121411A6 8 10 77757 7 57757807 7 1 771 772 772772773773773 774774774776777778779781782 40,994 SF 40,004 SF54,651 SF 42,305 SF 23 24 26 31 33 34 43,969 SF 42,094 SF 42,717 SF 40,649 SF 40,280 SF 25 32 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 26+002 7 + 0 0 28+ 0 0 29+00 30+00 31+0 0 AS CO -TRUSTEES OF THEANDREW QUENT IN PARR ISH 780 77 7 7 7 6 775774772 770 768 770770765775 776 770775774773 770 6 8 79775772772 773 774 40,230 SF 303140,280 SF 40,002 SF 2729 8''W 8 ' 'W 8'' W 8''W 8''W 8''W 8''WC6.5 BOATHOUSE WAY PLAN & PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:36 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSMATCHLINESHEET C6.4PROFILE SCALE 0 0 40 4 0 SCALE 1"=40' 80'40'NAD 83MATCHLINETHIS SHEET0 SCALE 1"=40' 80'40' NAD 8 3 SHEET C6.6MATCHLINESHEET C6 .6MATCHLINE MATC H LI N E THIS S H E E T H: 1" = 40' V: 1" = 4' 745 750 755 760 765 770 775 780 785 790 HORIZ SCALE: 1"=40' VERT SCALE: 1"=4 BOATHOUSE WAY 745 750 755 760 765 770 775 780 785 790 745 750 755 760 765 770 775 780 785 790 772.5774.1773.7772.4772.50774.11773.72772.4230+00 31+00 32+00 32+50 20' VC K = 20.00 A.D. = -1.00% PVI ELEV = 776.33 PVI STA = 31+81.29 HIGH PT STA = 31+91.28 HIGH POINT ELEV = 776.33 BVCS = 31+71.29BVCE = 776.23EVCS = 31+91.28EVCE = 776.33-0.00% EXISTING GROUND INTERSECTION W/ COLD WATER TERRACE FIRE HYDRANT ASSEMBLY 8" TEE W/ VALVE CONNECTION TO COLD WATER TERRACE WATERMAIN MAIN END CAP FOR PHASE 1 - REMOVE AND CONNECT FOR PHASE 2 30+00 31+00 31+93.29 24+0025+0026+0027+00COLDWATER TERRACEXXXX7 8 0 7777767757747 7 2 775 780 7 8 5 7 8 6 765 760 765 770 7 6 8 7 6 5 XXC4 C6 770 775 7 8 0 7 8 5 771 772 773 774 776 777 77 8 7 7 9 7 8 1 7 8 2 7 8 3 7 8 4 775 774 C5 40 , 2 3 0 S F 29 46,117 SF478''W8''W8''W8''W8''W 8''W8''WHORIZ SCALE: 1"=40' VERT SCALE: 1"=4 BRIGHT WATER LANE 780 785 790 795 800 805 810 815 820 825 780 785 790 795 800 805 810 815 820 825 793.8800.6800.6796.6796.7800.8805.2808.3806.2801.2793.80800.63800.59796.62796.69800.82805.18808.33806.16801.22-0+50 0+00 1+00 2+00 3+00 4+00 5+00 5+50 0.00% 0.00% 3.15% 0.00% 63' VC K = 20.00 A.D. = 3.15% PVI ELEV = 784.25 PVI STA = 0+42.02 LOW POINT STA = 0+10.53 LOW POINT ELEV = 784.25 BVCS = 0+10.53BVCE = 784.25EVCS = 0+73.51EVCE = 785.2463' VC K = 20.00 A.D. = -3.15% PVI ELEV = 797.34 PVI STA = 4+57.87 HIGH PT STA = 4+89.36 HIGH POINT ELEV = 797.34 BVCS = 4+26.38BVCE = 796.35EVCS = 4+89.36EVCE = 797.34EXISTING GROUND 8" TEE W/ VALVE CONNECTION TO COLDWATER TERRACE WATER MAIN 8"X6" TEE W/ 8" VALVE CONNECTION TO COLDWATER TERRACE WATERMAIN FIRE HYDRANT ASSEMBLY 8" PVC WATERMAIN 0 + 0 0 0 + 5 0 1 + 0 0 1+ 5 0 2+00 2+50 3+00 3+50 4+004+504+90.563+00 4+00 5+00 6+00 7+00 8+ 0 0 9+ 0 0 10 + 0 0 COL D W A T E R T E R R A C E BRIGHT W A T E R L A N E (50' R/W) 795 800 795 790 785 790795800805810 810812 805810820815810805800 795 790 775 780 785 790 795 800 805 810 80 5 80 0 7 9 5 803 25 27 2 6 48,420 S F 12 40, 0 3 7 S F 40,747 S F 9 8'' W 8'' W 8'' W 8'' W 8''W 8''W8''W 8''W 6''W 8''W 8'' W 8''W 8''W 8''W 8''W C6.6 ROAD PLAN & PROFILEM. MARTIN M. MARTIN R. RINGLER JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C6.0 - RDPROF.dwg | Plotted on 12/10/2020 1:37 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSMATCHLINESHEET C6.5PROFILE SCALE 0 0 40 4 0 SCALE 1"=40' 80'40' NAD 83 0 SCALE 1"=40' 80'40'NAD 83PROFILE SCALE 0 0 40 4 H: 1" = 40' V: 1" = 4' C7.0 NOTES AND DETAILSM. MARTIN M. MARTIN R. RINGLER AS SHOWN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C7.0 - NTDT.dwg | Plotted on 12/10/2020 1:37 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSNOTE HANDICAP SPACES FOR PHYSICALLY HANDICAPPED PERSONS SHALL BE IDENTIFIED BY ABOVE-GRADE SIGNS STATING "RESERVED PARKING". PROVIDE ONE R7-8 SIGN AT EACH HANDICAP PARKING, AS INDICATED ON THE SITE PLAN, ON EITHER A FACING WALL OR ON A 1-1/2" DIAMETER, STEEL POST, PAINTED BLACK, AND SET IN A 12" CONCRETE FOOTING, AS SHOWN ABOVE. THE SIGN WILL BE ALUMINUM (PAINTED WHITE), WITH GREEN LETTERS AND INTERNATIONAL WHEELCHAIR SYMBOL. THE BOTTOM OF THE SIGN SHALL BE FIVE FEET ABOVE GRADE. TYPICAL ACCESSIBLE SIGNS SHALL CONFORM TO THE SOUTH CAROLINA ACCESSIBILITY CODE.1/4" PER 1' MAX.1/4" PER 1' MAX. HANDICAP PARKING DETAIL NO SCALE 8' MIN.8' MIN.8' MIN.9' 18' WHEEL STOP (TYP.) 3' PRECAST BUMPER BLOCK (WHEEL STOP) NO SCALE 7-1/2" 5" ANCHOR WITH 5 8" REBAR IMBEDDED 24" IN GROUND (2 PER WHEEL STOP) 6'-0" LENGTH MAXIMUM PENALTY $250 RESERVED PARKING ACCESSIBLE VAN HANDICAP PARKING SIGN NO SCALE SLOPE TO DRAIN TOP OF CONCRETE FOOTING SIGN FACE TO BE ATTACHED TO POST W/ GALVANIZED CARRIAGE BOLTS SIGN R7-8 SIGN R7-8 SIGN R7-8D PLACED UNDER SIGN PLACED OVER SIGN AT VAN PARKING SPACE 9" 18" 9" 12" 12" DIA. 12"60"(CONDITION 1)4" ADA ACCESSIBLE PARKING SIGNS #57 WASHED STONE PLACED TO A HEIGHT OF 16" MINIMUM ABOVE THE TOP OF BOX GALVANIZED HARDWARE WIRE EXTENDS TO THE TOP OF THE BOX STANDARD METAL POSTS 2'-0" IN GROUND MAINTENANCE INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. INLET PROTECTION NO SCALE CROSS SECTION PROPOSED STREET, 25' OR WIDTH OF WHICHEVER IS EXISTING ROADWAY 6" MIN. PLAN VIEW 35' MIN. ROADWAY EXISTING 50' MIN. GREATER. NEW CONSTRUCTION15' MIN. 12" MIN. 2"-3" STONE TO BE USED (SURGE STONE OR RAILROAD BALLAST) BUT SUFFICIENT TO KEEP SEDIMENT ON SITE FABRIC UNDER STONE NOTES: 1. PUT SILT FENCE OR TREE PROTECTION FENCE UP TO ENSURE CONSTRUCTION ENTRANCE IS USED. 2. IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD IS NOT REMOVED BY THE VEHICLE TRAVELING OVER THE STONE, THEN THE TIRES OF THE VEHICLES MUST BE WASHED BEFORE ENTERING THE PUBLIC ROAD. 3. MAINTAIN GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING CONSTRUCTION SITE. ENTRANCE WILL REQUIRE PERIODIC REMOVAL OF SEDIMENT-LADEN STONE AND REPLACEMENT WITH FRESH STONE. MAINTENANCE MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH TWO-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. EXISTING ROADWAY 6" MIN. 35' MIN. NEW CONSTRUCTION 15' MIN. 12" MIN. FABRIC UNDER STONE ENTRANCE GRADE GREATER THAN 2% 6" TO 8" STONE RIDGE NOTES: 1. L = THE LENGTH OF THE RIPRAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (INCHES). 3. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. A A I.D. PLAN VIEW SECTION 'A-A' FILTER FABRIC d L PIPE PIPE MAINTENANCE RIP RAP SHOULD BE INSPECTED PERIODICALLY FOR SCOUR OR DISLODGED STONES. CONTROL OF WEED AND BRUSH GROWTH MAY BE NEEDED IN SOME LOCATIONS. OUTLET PROTECTION NO SCALE 3 * I.D. L W FI L L S L O P E WASTE MATERIAL-COMPACT, SEED & MULCH AFTER CONSTRUCTION OF DITCHVAR. 2' - 10' VAR. 0' - 2' CROSS SECTIONAL VIEW 2:1 M A X . 2:1 M A X. 12" 2' MIN. 12" MAINTENANCE INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT.2:1 MAX. 2 : 1 M A X . TEMPORARY DIVERSION DITCH (*NCDEQ 6.20) NOT TO SCALE NOTES: 1. TEMPORARY DIVERSION DITCH TO BE USED TO INTERCEPT FLOW AND/OR DIVERT TO A SEDIMENT CONTROL MEASURE OR BMP. 2. SILT SHALL BE REMOVED WHEN DITCH IS ONE-HALF FULL. 3. DITCH SHALL BE RECONSTRUCTED WHEN DAMAGED BY EQUIPMENT OR COVERED BY FILL. 4. STABILIZE DIVERSION DITCH BERM WITH TEMPORARY SEEDING, MULCH WITH TAC, AND/OR EROSION CONTROL NETTING 5.LINE DITCH BENDS W/ CLASS A RIPRAP EMERGENCY SPILLWAY ELEVATION 2:1 SLOPE ELEVATION 2:1 SLOPETOP OF DAM TEMPORARY SKIMMER SCHEDULE 40 PVC PIPE POROUS BAFFLES OF DAM CENTERLINE CONNECT FLEXIBLE TUBING TO ORIFICE 2:1AT ENTRANCE (CREST) OF SPILLWAY NO SCALE EMERGENCY SPILLWAY DETAIL2:1 DEPTH W NOTE: INSTALL RUBBER GASKETS ON ALL PIPE JOINTS TEMPORARY SKIMMER BASIN NO SCALE 2'x2' VELOCITY DISSIPATOR W/ 8" DEPTH CLASS A RIPRAP SUPPORT ROPE TO WIRE TO PREVENT SAGGING SUPPORT POST 24" INTRO BOTTOM OR SIDE COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE OUTLET ZONE NOTES: 1.BAFFLE MATERIAL SHOULD BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR SILT FENCE. 2.MOST OF THE SEDIMENT WILL ACCUMULATE IN THE 1ST BAY, WHICH SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. 3.PROVIDE 3 BAFFLES (USE TWO IF LESS THAN 20 FEET IN LENGTH). PROVIDE 5 BAFFLES FOR DRAINAGE AREAS GREATER THAN 10 ACRES. 4.BAFFLE SHALL BE 700 G/M2 COIR EROSION BLANKET. 5.TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS 6.INSPECT BAFFLES FOR REPAIR ONCE A WEEK AND AFTER EACH RAINFALL INLET ZONE 35% of basin surface area 1st Cell 25% of basin surface area 2nd Cell 25% of basin surface area 15% of basin surface area CROSS SECTION PLAN VIEW SECTION VIEW AT OPENING FENCE AND FABRIC BURIED IN TRENCH 6"X6" TRENCH, BACKFILLED AND COMPACTED STEEL POST MAINTENANCE INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHES HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. POROUS BAFFLES NO SCALE CROSS SECTIONAL VIEW PERMANENT SWALE/ CLEAN WATER DIVERSION INSTALLATION NO SCALE 3: 1 M A X . 3:1 M A X. 12" CONTRACTOR TO PLACE MIN. 6" OF TOPSOIL, SEED AND INSTALL BIONET C125BN MATTING SILT FENCE N.T.S C7.1 NOTES AND DETAILSM. MARTIN M. MARTIN R. RINGLER AS SHOWN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C7.0 - NTDT.dwg | Plotted on 12/10/2020 1:37 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSNOTES BASIN SHOULD BE CLEANED OUT WHEN CAPACITY REACHES AN ELEVATION REPRESENTING THAT THE SEDIMENT STORAGE ZONE IS HALF-FULL OR EVERY 90 DAYS WHICHEVER COMES FIRST. THE TARP USED TO PROTECT THE WEIR SHALL BE THE WIDTH SPECIFIED. THE LENGTH OF THE TARP SHALL BE ACCORDING TO AVAILABLE SUPPLY. IF MULTIPLE TARPS ARE TO BE USED, THEN TARPS SHALL BE OVERLAPPED AT LEAST 12". THE UPSTREAM 12" TARP SHALL OVERLAP THE DOWNSTREAM TARP. THE TARP SHALL BE 50 MIL. HEAVY DUTY SILVER TARPAULINS OR EQUIVALENT FOR U.V. RESISTANCE. PROVIDE A MINIMUM OF THREE POROUS BAFFLES TO EVENLY DISTRIBUTE FLOW ACROSS THE BASIN, REDUCING TURBULENCE. BAFFLE MATERIAL MUST BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR A SILT FENCE. MOST OF THE SEDIMENT WILL ACCUMULATE IN THE FIRST BAY, SO THIS SHOULD BE READILY AVAILABLE FOR MAINTENANCE. POND SHALL NOT BE CONVERTED FOR STORMWATER USE UNTIL APPROVED BY ENVIRONMENTAL ENGINEER. VENT SCREEN ACCESSIBLE THROUGH DOOR FLOAT BARREL PIPE LONGER THAN SHOWN. FLEXIBLE JOINT (RADIATOR HOSE) OUTLET END: CONNECTION TO OUTLET PIPE OR RISER MAINTENANCE INSPECT TEMPORARY SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. PLACE REMOVED SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASING, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO REMOVE THE DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA. GROUND STABILIZATION SITE AREA DESCRIPTION STABILIZATION TIME FRAME STABILIZATION TIME EXCEPTIONS ·PERIMETER DIKES, SWALES, DITCHES, AND SLOPES ·HIGH QUALITY WATER (HQW) ZONES ·SLOPES STEEPER THAN 3:1 ·SLOPES 3:1 OR FLATTER ·ALL OTHER AREA WITH SLOPE FLATTER THAN 4:1 7 DAYS NONE 7 DAYS NONE 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1 14 DAYS ARE ALLOWED 14 DAYS 14 DAYS 7-DAYS FOR SLOPES GREATER THAN 50 FEET IN LENGTH NONE (EXCEPT FOR PERIMETERS AND HQW ZONES) * "EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE COMPLIANCE IMPRACTICABLE." (SECTION II. B (2)(b)) PERMANENT SEEDING PREPARE SEEDBED BY RIPPING, CHISELING, HARROWING, OR PLOWING TO DEPTH OF SIX INCHES SO AS TO PRODUCE A LOOSE, FRIABLE SURFACE. REMOVE ALL STONES, BOULDERS, STUMPS, OR DEBRIS FROM THE SURFACE WHICH WOULD PROHIBIT GERMINATION OR PLANT GROWTH. INCORPORATE INTO THE SOIL 800 TO 1,000 POUNDS OF 10-10-10 FERTILIZER PLUS 500 POUNDS OF 20-PERCENT SUPERPHOSPHATE PER ACRE AND TWO TONS OF DOLOMITIC LIME PER ACRE UNLESS SOIL TESTS INDICATE THAT A LOWER RATE OF LIME CAN BE USED. MULCH AFTER SEEDING WITH 1.5 TONS OF GRAIN STRAW PER ACRE AND EITHER CRIMP STRAW INTO SOIL OR TACK WITH LIQUID ASPHALT AT 400 GALLONS PER ACRE OR EMULSIFIED ASPHALT AT 300 GALLONS PER ACRE. PERMANENT SEEDINGS: PLANTS & MIXTURE PLANTING RATE/ACRE PLANTING DATES TALL FESCUE 110 LBS AUG 15 - OCT 15 JAPANESE CLOVER FEB 15 - MAY 1 CHINESE LESPEDEZA (LOW MAINTENANCE SLOPE 3:1 OR LESS) TALL FESCUE 140 LBS AUG 15 - OCT 15 JAPANESE CLOVER FEB 15 - MAY 1 CHINESE LESPEDEZA (LOW MAINTENANCE SLOPE STEEPER THAN 3:1) BLEND OF TWO TURFTYPE 200 LBS AUG 15 - OCT 15 TALL FESCUES (90%) AND FEB 15 - MAY 1 TWO OF MORE IMPROVED KENTUCKY BLUEGRASS VARIETIES (10%) (GENERAL LAWN AREAS) * REFER TO THE SPECIFICATIONS AND MAINTENANCE REQUIREMENTS IN THE "NORTH CAROLINA EROSION CONTROL PLANNING MANUAL" JUNE 1, 2006 EDITION. FOR SPRING SEEDINGS, USE SCARIFIED LESPEDEZA SEED. FOR LATE FALL AND WINTER SEEDINGS, USE UNSCARIFIED SEEDS. EROSION CONTROL MATTING SHALL BE PROVIDED ON ALL SLOPES 3:1 AND GREATER. SUMMER TEMPORARY SEEDING (PIEDMONT REGION) SEEDING MIXTURE SPECIES RATE (lb/ACRE) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL-STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 lb/ACRE. SEEDING DATES MOUNTAINS-MAY 15 - AUG. 15 PIEDMONT-MAY 1 - AUG. 15 COASTAL PLAIN-APR. 15 - AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 lb/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 lb/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. FALL TEMPORARY SEEDING (PIEDMONT REGION) SEEDING MIXTURE SPECIES RATE (lb/ACRE) RYE (GRAIN) 120 SEEDING DATES MOUNTAINS-AUG. 15 - DEC. 15 COASTAL PLAIN AND PIEDMONT-AUG. 15 - DEC. 30 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 lb/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 lb/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. LATE WINTER/EARLY SPRING TEMPORARY SEEDING (PIEDMONT REGION) OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SEEDING DATES MOUNTAINS - ABOVE 2500 FT: FEB. 15 - MAY 15 BELOW 2500 FT: FEB. 1 - MAY 1 PIEDMONT - JAN. 1 - MAY 1 COASTAL PLAIN-DEC. 1 - APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 lb/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 lb/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. SEEDING MIXTURE SPECIES RATE (lb/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 **REFER TO THE SPECIFICATIONS AND MAINTENANCE REQUIREMENTS IN THE "NORTH CAROLINA EROSION CONTROL PLANNING MANUAL" JUNE 1, 2006 EDITION. PIPE CLASS B RIP-RAPFLOWNCDOT #5 OR #57 STONE 1' THICK x 2' HIGH (MINIMUM) FLOW FLOW SEDIMENT STORAGE AREA PERSPECTIVE VIEW PIPE2'FINISHED GRADE CLASS B RIP-RAP 1.5'MAX SEDIMENT DEPTH (CLEAN OUT POINT) SEDIMENT STORAGE ZONE FLOOD STORAGE ZONE NCDOT #5 OR #57 STONE FLO W 2'1'3' CONSTRUCTION SPECIFICATIONS: 1.CLEAR THE AREA OF ALL DEBRIS THAT MIGHT HINDER EXCAVATION AND DISPOSAL OF SPOIL. 2.INSTALL THE CLASS B OR CLASS I RIPRAP IN A SEMI-CIRCLE AROUND THE PIPE INLET. THE STONE SHOULD BE BUILT UP HIGHER ON EACH END WHERE IT TIES INTO THE EMBANKMENT. THE MINIMUM CREST WIDTH OF THE RIP-RAP SHOULD BE 3 FEET, WITH A MINIMUM BOTTOM WIDTH OF 11 FEET. THE MINIMUM HEIGHT SHOULD BE 2 FEET, BUT ALSO 1 FOOT LOWER THAN THE SHOULDER OF THE EMBANKMENT OR DIVERSIONS. 3.A 1 FOOT THICK LAYER OF NC DOT #5 OR #57 STONE SHOULD BE PLACED ON THE OUTSIDE SLOPE OF THE RIPRAP. 4.THE SEDIMENT STORAGE AREA SHOULD BE EXCAVATED AROUND THE OUTSIDE OF THE STONE HORSESHOE 18 INCHES BELOW NATURAL GRADE. 5.WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, FILL DEPRESSION AND ESTABLISH FINAL GRADING ELEVATIONS, COMPACT AREA PROPERLY, AND STABILIZE WITH GROUND COVER. MAINTENANCE: 1.INSPECT ROCK PIPE INLET PROTECTION AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2" OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. 2.CHECK THE STRUCTURE FOR DAMAGE. ANY RIPRAP DISPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY. 3.AFTER ALL THE SEDIMENT AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER (SURFACE STABILIZATION). RIP-RAP HEAD WALL, 1' MIN HEIGHT FROM ROAD SHOULDER ROCK PIPE INLET PROTECTION (*NCDEQ 6.55) BRIDGE DETAIL N.T.S 20' ASPHALT PAVEMENT (PER TYP. RESIDENTIAL COLLECTOR ROAD DETAIL) RETAINING WALL (STRUCTURAL DESIGN BY OTHERS) 36 LF ARCHED CULVERT (REFER TO GRADING PLAN) EXISTING GRADE WATER MAIN NOTE: TEMPORARY SEEDING TO BE USED WHEN OUTSIDE OF SPECIFIED PERMANENT SEEDING PLANTING DATES. COFFER DAM W/ PUMP CONFIGURATION N.T.SFLOW COFFER DAM NATURAL STREAM BED HOSE PUMP RIP-RAP AREA OF NEW CONSTRUCTION FOR NEW ROAD CROSSING PROPOSED CULVERT PUMP SILT BAG 7' GRASSED SHOULDER CONVEYANCE SWALE FLEXIBLE PIPE SLOPE DRAIN (NCDEQ 6.32)N.T.S. C7.2 NOTES AND DETAILSM. MARTIN M. MARTIN R. RINGLER AS SHOWN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C7.0 - NTDT.dwg | Plotted on 12/10/2020 1:37 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSNOTE: ALL METERS ARE TO BE LOCATED OUTSIDE OF ANY ASPHALT PAVEMENT. METERS ARE TO BE LOCATED BEHIND/OUT OF THE DITCH. ANY METER OUTSIDE THE RIGHT-OF-WAY TO HAVE 4' EASEMENT ON ALL SIDES TO ALLOW THE TOWN OF STOKESDALE ACCESS FOR MAINTENANCE AND ACCESS. NOTE: ALL VALVES ARE TO BE LOCATED OUTSIDE OF ANY ASPHALT PAVEMENT. FIRE HYDRANTS ARE TO BE LOCATED BEHIND THE DITCH SO THE SHOULDER CAN REMAIN OPEN FOR VEHICULAR RECOVERY AREA AND TO ALLOW NCDOT TO MAINTAIN SHOULDER AND DITCH. C7.3 NOTES AND DETAILSM. MARTIN M. MARTIN R. RINGLER AS SHOWN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C7.0 - NTDT.dwg | Plotted on 12/10/2020 1:37 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSFigure A Figure D Ground Surface Figure C - Cross Section ViewFigure B - Profile View Figure F - Profile View Figure E Figure G - Critical Points Toe of Slope Crest of Slope Ground Surface Ground Surface FlowPrepare site to design profile and grade. Remove debris, rocks, clods, etc.. Ground surface should be smooth prior to installation to ensure blanket remains in contact with slope. Seeding of site should be conducted to design requirements or to follow local or state seeding requirements as necessary. At a minimum, 6" long by 1" crown, 11 gauge staples are to be used to secure the blanket to the ground surface. Installation in rocky, sandy or other loose soil may require longer staples. Excavate a trench along the top of the channel side slopes and the upstream terminal end of the channel to secure the edges of the blanket. The trench should run along the length and width of the installation, be 6" wide and 6" deep. Staple blanket along bottom of trench, fill with compacted soil, overlap blanket towards toe of slope and secure with row of staples (shown in Figures A, E and F). Step 4 - Excavate Anchor Trench and Secure Blanket Step 5 - Secure Body of Blanket Roll blanket down slope from anchor trench. Staple body of blanket following the pattern shown in Figure D. Leave end of blanket unstapled to allow for overlap shown in Figure B. Place downstream blanket underneath upstream blanket to from shingle pattern. Staple seam as shown in Figure E. Secure downstream blanket with stapling pattern shown in Figure D. Stapling pattern shown in Figure D reflects minimum staples to be used. More staples may be required to ensure blanket is sufficiently secured to resist mowers and foot traffic and to ensure blanket is in contact with soil surface over the entire area of blanket. Further, critical points require additional staples. Critical points are identified in Figure G. Step 6 - Continue Along Slope - Complete Installation Overlap adjacent blankets as shown in Figure C and repeat Step 5. Secure toe of slope using stapling pattern shown in Figure E. Secure edges of installation by stapling at 1.5' intervals along the terminal edge. Crest of Slope Figure CFigure C Blanket 3 Blanket 2 Blanket 1 Blanket 2 Blanket 1 Flow Blanket 2 Blanket 3 Figure E - Plan View Figure D - Plan View - Denotes Staple Location - Denotes Staple Location - Denotes Staple Location CHANNEL INSTALLATION INSTRUCTIONS *Approximately 360 Staples per 7.5' Roll & 720 Staples per 15' Roll Required - Drawings Not to Scale 15' Wide Blanket Shown SLOPE MATTING INSTALLATION (NCDEQ 6.17)N.T.S. C7.4 NOTES AND DETAILSM. MARTIN M. MARTIN R. RINGLER AS SHOWN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.8642 W. Market Street Suite 136 | Greensboro, NC 27409TEL 336.662.0411 FAX 336.662.0420 www.timmons.comNorth Carolina License No. C-1652THIS DRAWING PREPARED AT THEGREENSBORO OFFICES:\107\44636-Coldwater\DWG\Sheet\CD\C7.0 - NTDT.dwg | Plotted on 12/10/2020 1:37 PM | by Maegan Martin08/21/2020 COLDWATERGUILFORD AND FORSYTH COUNTY - NORTH CAROLINA44636 PRELIMINARY - NOT FOR CONSTRUCTION 12/10/2020 10/09/2020RESUBMITTAL #110/23/2020RESUBMITTAL #212/01/2020NCDOT COMMENTS12/10/2020GUILFORD COUNTY COMMENTSNCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1.Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2.Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3.Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4.Provide ponding area for containment of treated Stormwater before discharging offsite. 5.Store flocculants in leak-proof containers that are kept under storm-resistant cover or surrounded by secondary containment structures. HAZARDOUS AND TOXIC WASTE 1.Create designated hazardous waste collection areas on-site. 2.Place hazardous waste containers under cover or in secondary containment. 3.Do not store hazardous chemicals, drums or bagged materials directly on the ground. EQUIPMENT AND VEHICLE MAINTENANCE 1.Maintain vehicles and equipment to prevent discharge of fluids. 2.Provide drip pans under any stored equipment. 3.Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4.Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5.Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6.Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1.Never bury or burn waste. Place litter and debris in approved waste containers. 2.Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3.Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4.Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5.Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6.Anchor all lightweight items in waste containers during times of high winds. 7.Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8.Dispose waste off-site at an approved disposal facility. 9.On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1.Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2.Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3.Contain liquid wastes in a controlled area. 4.Containment must be labeled, sized and placed appropriately for the needs of site. 5.Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1.Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2.Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3.Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. HERBICIDES, PESTICIDES AND RODENTICIDES 1.Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2.Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3.Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4.Do not stockpile these materials onsite. CONCRETE WASHOUTS 1.Do not discharge concrete or cement slurry from the site. 2.Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3.Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4.Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5.Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6.Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7.Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8.Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9.Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10.At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. EARTHEN STOCKPILE MANAGEMENT 1.Show stockpile locations on plans. Locate earthen-material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2.Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3.Provide stable stone access point when feasible. 4.Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. Site Area Description Timeframe variations -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unless there is zero slope Stabilize within this many calendar days after ceasing land disturbance 7 7 7 14 None None (a)Perimeter dikes, swales, ditches, and perimeter slopes (b)High Quality Water (HQW) Zones (c)Slopes steeper than 3:1 If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed (d)Slopes 3:1 to 4:1 (e)Areas with slopes flatter than 4:1 14 -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF-INSPECTION Self-inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self-inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1.E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical: (a)This General Permit as well as the Certificate of Coverage, after it is received. (b)Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically-available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard-copy records. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1.Occurrences that Must be Reported Permittees shall report the following occurrences: (a)Visible sediment deposition in a stream or wetland. (b)Oil spills if: ·They are 25 gallons or more, ·They are less than 25 gallons but cannot be cleaned up within 24 hours, ·They cause sheen on surface waters (regardless of volume), or ·They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d)Anticipated bypasses and unanticipated bypasses. (e)Noncompliance with the conditions of this permit that may endanger health or the environment. 2.Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. 3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a)The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in which it will occur. The non-surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b)The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c)Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d)Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e)Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f)Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States.