Loading...
HomeMy WebLinkAbout20201231 Ver 1_USACE Permit_20201211U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action ID. SAW-2020-01907 County: Buncombe GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION Permittee: City of Asheville / Attn: Amy Denton Address: 161 South Charlotte Street Asheville, NC 28801 Telephone Number: 828-259-5547 Location description: The site is located on Pebble Creek Drive, in Asheville, NC. Description of projects area and activity: This permit authorizes bank stabilization activities. Impacts authorized by this permit total 291 linear feet of permanent impacts and 47 linear feet of temporary/dewatering impacts. Attached are recommendations from the North Carolina Wildlife Resource Commission for your consideration. Applicable Law: ® Section 404 (Clean Water Act, 33 USC 1344) ❑ Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: Regional General Permit Number or Nationwide Permit Number: 27 SEE ATTACHED RGP or NWP GENERAL, REGIONAL AND SPECIAL CONDITIONS Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the attached conditions, above noted special conditions, and your submitted application and attached information dated October 29, 2020. Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide/regional authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide/regional permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide/regional permit. If the nationwide/regional permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide/regional permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide/regional permit, will remain authorized provided the activity is completed within twelve months of the date of the nationwide/regional permit's expiration, modification or revocation, unless discretionary authority has been exercised on a case -by -case basis to modify, suspend or revoke the authorization. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (LAMA), prior to beginning work you must contact the N.C. Division of Coastal Management. This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program, please contact Amanda Jones at 828-271-7980, ext. 4225 or amanda.jones@usace.army.mil. FUEMMELER.AMAN Digitally signed by DA.JONES.1242835 FUEMMELER.AMANDAJONE5.124 28351190 Corps Regulatory Official: 090 Date: 2020.12.1111:28.449-05'00' Date: December 11, 2020 Amanda Jones Expiration Date of Verification: March 18, 2022 CF: McAdams Company / Attn: Amanda Bloom (via email) Action ID Number: SAW-2020-01907 County: Buncombe Permittee: City of Asheville / Attn: Amy Deyton Project Name: Pebble Creek Stabilization / NWP #27 Date Verification Issued: December 11, 2020 Project Manager: Amanda Jones Upon completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Attn.: Amanda Jones 151 Patton Avenue, Room 208 Asheville, North Carolina 28801-5006 Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit, and required mitigation was completed in accordance with the permit conditions. Signature of Permittee Date 0 North Carolina Wildlife Resources Commission 0 Gordon Myers, Executive Director November 23, 2020 Ms. Amanda Fuemmeler U.S. Army Corps of Engineers, Regulatory Branch 151 Patton Avenue, Room 208 Asheville, North Carolina 28801-5006 SUBJECT: Pebble Creek Restoration Dingle Creek, Buncombe County Dear Ms. Fuemmeler: Biologists with the North Carolina Wildlife Resources Commission (NCWRC) reviewed an application to stabilize 291 ft of Dingle Creek in Buncombe County. Our comments on this application are offered for your consideration under provisions of the Clean Water Act of 1977 (33 U.S.C. 466 et. seq.) and Fish and Wildlife Coordination Act (48 Stat. 401, as amended; 16 U.S.C. 661-667d). Wild trout reproduction should not be impacted by project activities, and a trout moratorium is not required for this project. The project involves stabilizing erosion on Dingle Creek, much of which was previously armored with gabion baskets, which are now failing. The design proposes to remove the gabion baskets and replace them with gravity retaining walls (essentially concrete blocks), install a boulder cross vane, harden the channel, and clean sediment out of existing culverts. Work will be done in the dry. It appears that Dingle Creek is highly constrained by a sewer line and infrastructure, with roads and building 10-40 ft from the stream. Although a limited set of instream structures may be appropriate, we recommend against hardening the channel as designed. In addition, we recommend alternative options to using concrete blocks to stabilize the channel, such as geolifts. We offer the following recommendations to minimize impacts to the aquatic community: 1. Work should be accomplished as quickly as possible and vigilance used in sediment and erosion control during site preparation, construction, and clean up. Disturbed areas should be seeded, mulched and/or matted as soon as possible, preferably at the end of each workday. Mailing Address: Habitat Conservation • 1721 Mail Service Center • Raleigh, NC 27699-1721 Telephone: (919) 707-0220 • Fax: (919) 707-0028 Pebble Creek Restoration Dingle Cr, Buncombe County November 23, 2020 2. Any erosion control matting used should be free of plastic or nylon mesh, as this type of mesh netting frequently entangles wildlife and is slow to degrade, resulting in a hazard that may last for years. 3. We recommend against hardening the channel and banks with rock and concrete. We recommend limiting the amount of in -stream structures to those only needed for channel stability and exploring bioengineering alternatives to gravity retaining walls. 4. Channel work should ensure that stream channel elevation allows substrate retention within the culverts to ensure aquatic organism passage. 5. We support the permanent riparian seed mix. In addition, we recommend planting as many native woody shrubs and trees as possible to provide bank stability, shade Dingle Creek, treat stormwater driven pollutants, and benefit wildlife. Thank you for the opportunity to review and comment on this project. Please contact me at (828) 400-4223 if you have any questions about these comments. Sincerely, Andrea Leslie Mountain Region Coordinator, Habitat Conservation Program ec: Amy Bloom, McAdams Company Andrew Moore, NC Division of Water Resources 3 N N �_ C .N N N N V _N Q N Q BEGIN WA _ STA. 0+00 \ SMH� RIM 21L.._ 1 2173.5 INV. 21 \ C \ o \ I \ I \ — I \ ai N- \ ss - _ — u `ss--�- r-- A SMH �� ----- END WALL #1 RIM 2181.81 2175-6,'ASS —STA. 0+92± 2. 7 sw ss cv END WALL #2 �� � SF ��� SF � �, ,-�__ ^' / �� SF D _ 'STA.0+98±LD J \ \ ORIN / 1 I / - I / ss _ N 24- 301 3D1 3n — 3C1 \ � d oLL — 2�r 12" Q HOLLY Tl9 OF 4" °�— 22+&0 4° MN 1EUBI MOIi _o \ Lm - o _ I I I i � INV � I 17� \ � I_ _ PVC• �� � ♦ BEGIN WALL #2 R INE \ ILL PIPE, N TA 0+00 \ \ OR PE: � 21•$9 ♦ — ----_ S\ , \ 7 / / \ \o +I +I +I O N �O + t t t 0 0 0 0 d d a a V) G V) V) +10 _ • <D \� OAK ` \ LD — LD LD tiv pe � OAK \ TICE TICE_ \ ` rcE RFC I +20 +30 +40 +60 +70 +80 +90 0+00 0+50 WALL STATION (FT.) GRAVITY RETAINING WALL #1 FACE ELEVATION SCALE: 1 "=10' HORIZONTAL / 1 "=5' VERTICAL 2184 2182 2180 2178 Oz 2176 w J w 2174 2172 2170 1+00 WALL LOCATION PLAN LEGEND: - GRAVITY RETAINING WALL LOCATION REFERENCE WALL LOCATION PLAN COPIED FROM "GRADING & EROSION CONTROL" PLAN (SHEET C3.00) AND ASSOCIATED AUTOCAD FILE (2020-09-04 COA19000x.DWG) PREPARED BY MCADAMS ON SEPTEMBER 4, 2020. NOTE WALL LOCATION PLAN IS SHOWN FOR REFERENCE ONLY, DO NOT USE FOR WALL LAYOUT OR CONSTRUCTION. LEGEND FINISHED GRADE BEHIND WALL (FGB) FINISHED GRADE IN FRONT OF WALL (FGF) ❑ 46"Lx28"Wx18"H SOLID GRAVITY UNITS 46"Lx41 "Wx18"H SOLID GRAVITY UNITS 0 10 120 30 OAK GRAPHIC SCALE (IN FEET) I +I +I +I O N l�0 + + + + O O O O Q Q Q Q V) V) V) V) +10 +20 +30 +40 +60 +70 +80 0+00 0+50 WALL STATION (FT.) GRAVITY RETAINING WALL #2 FACE ELEVATION SCALE: 1 "=10' HORIZONTAL / 1 "=5' VERTICAL +90 1+00 2184 2182 2180 2178 2176 2174 2172 2170 af O LL 0 Lu 44 BUCK SHOALS RD, SUITE C-3 ARDEN, NC 28704 (828)-687-9080 ENGINEERING FIRM LICENSE NUMBER: F-0176 O w ~ co N Q 5� un N > z_ J F-� �j V Q z = Uz z o z 0 W O J M Q _ V CARO�-'� �(0 6FESS/o SEAL 028091 -x G �v ° -i7- =a �t T z O V Z N _O z O a V � Ce LA O W LL Q G W H IA 1441-19-021 DRAWING NUMBER R2 I of 3 FENCE OR HANDRAILS - (SHOWN FOR INSTALLATION ONLY) FENCE OR HANDRAIL POSTS SHALL BE INSTALLED IN SONOTUBES (PLACED DURING WALL CONSTRUCTION) AND BACKFILLED WITH CONCRETE OR GROUT, DRIVEN AFTER WALL CONSTRUCTION OR INSTALLED IN HAND DUG POST HOLES. POSTS SHALL BE INSTALLED NO CLOSER THAN 28 INCHES FROM FACE OF UPPER GRAVITY UNIT. AUGERING BEHIND WALL IS NOT ALLOWED. DETAIL SHOWN FOR INSTALLATION ONLY. ACTUAL DESIGN OF FENCE POST SUPPORT SHOULD BE PERFORMED BY MANUFACTURER AND/OR STRUCTURAL ENGINEER. SETBACK = 1 s"± 5° WALL BATTER 28" TOP UNIT TOW (TOP OF WALL) MOVE UNITS FORWARD DURING INSTALLTION TO ENGAGE SHEAR KNOBS (TYPICAL) 7.5' (MAX.) (SEE ELEVATIONS ON R2 FOR GRAVITY UNIT LAYOUT) BOW (BOTTOM OF WALL) 28" MIDDLE UNITS (TYP.) 41" MIDDLE UNITS (TYP.) STREAM BANK STABILIZATION - SEE CIVIL PLANS (DESIGN BY OTHERS) FINISHED GRADE IN FRONT OF WALL - VARIES VARIES 41" BOTTOM U eIT11 (18" MIN.) /I///,i,%// 12" (MIN.) UNDERCUT/STABILIZATION PER FIELD ENGINEER EVALUATION AND RECOMMENDATIONS 30" (MIN.) FENCE POST (TYP.) l M ° a A _ <A A v A ° 5'-0" °A. EVALUATED AND APPROVED SUBGRADE SOILS SUITABLE TO SUPPORT A DESIGN CONTACT PRESSURE OF 2,000 PSF (MINIMUM) LOW PERMEABILITY SOIL OR CONCRETE FINISHED GRADE BEHIND WALL - VARIES (SLOPE AWAY FROM BACK OF WALL) CLASS 3000 CONCRETE OR GROUT - 1 DRAINAGE AGGREGATE (NC DOT NO. 57 STONE) ------ W__NON-WOVEN FILTER FABRIC 4"0 PERFORATED DRAINAGE PIPE CONNECTED TO WEEP HOLES (SEE DETAIL 3 ON R3) � A RETAINED BACKFILL ZONE VA\VA�VA�VA�VA� SLOPE INCLINATIONS SHALL BE IN ACCORDANCE WITH LOCAL, STATE 1b o 0 0 \\ \\ \\ \\ AND OSHA REGULATIONS (DO NOT UNDERMINE EXISTING BUILDING FOOTINGS) CRUSHENE LEVELING PAD (NCDOTDNO. 057 STONE WRAPPED \ \ WITH NON -WOVEN FILTER FABRIC) \ \ //x / 1 TYPICAL GRAVITY RETAINING WALL SECTION R3� SCALE: Not to Scale NOTE: PVC drainage weep hole not shown for clarity. (See Detail 3 on Sheet R3) lL-1) �,J( L/�� L lL/-/) "J J J J U 'c J L/ I ,`Il J V DLEUNI i 1� /� BOTTOM UNITFT J I TBOTTOM NIT J� BOTTOM ��� UNIT J `' 122" MIN.�o 6" (MINIMUM) /\\//\\ CRUSHED STONE FOOTING 1:1 OR FLATTER BOTTOM HALF UNIT 12" MIN. HDPE DRAIN PIPE THROUGH NOTCHED HOLE AND GROUT PIPE IN PLAC DRAIN PIPE THROUGH NOTCHED HOLE =GRATED SPECIFICATIONS 1.0 GENERAL CONSTRUCTION AND INSPECTION OF THE GRAVITY RETAINING WALL SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE BLOCK MANUFACTURER, THE ELEVATION VIEWS, DETAIL(S), AND THESE SPECIFICATIONS. 2.0 MATERIALS 2.1 SOIL INSTALLED IN THE RETAINED ZONE SHALL BE FREE OF ORGANIC OR OTHER DELETERIOUS MATERIALS MEETING THE FOLLOWING CRITERIA: • USCS MATERIAL TYPE: SM, SC, SW • AASHTO MATERIAL TYPE: A-1, A-2, A-3 • EFFECTIVE ANGLE OF INTERNAL FRICTION, �' = 28' • MAXIMUM PARTICLE SIZE = 3/4" • PERCENT PASSING NO. 200 SIEVE < 35 • LIQUID LIMIT, LL<40 • PLASTIC INDEX, PI <_ 10 • ORGANIC MATERIAL < 0.5% • 3<pH<9 REPRESENTATIVE SAMPLES SHALL BE SUBJECTED TO THE FOLLOWING TESTING: • GRAIN SIZE DISTRIBUTION - ASTM D-422 • ATTERBERG LIMITS - ASTM D-4318 • STANDARD PROCTOR COMPACTION - ASTM D-698 • DIRECT SHEAR - ASTM D-3080 THE WALL CONTRACTOR SHALL SUBMIT LABORATORY TEST RESULTS TO THE WALL ENGINEER FOR APPROVAL AND TO CONFIRM THAT SOIL INSTALLED IN THE RETAINED ZONE MEETS THE REQUIREMENTS OF SECTION 2.1. 2.2 GRAVITY UNITS - GRAVITY UNITS SHALL CONSIST OF WET -CAST PRECAST "SOLID" MODULAR UNITS (CONFORMING TO ASTM C1776) IN A SOUND CONDITION FREE OF CRACKS OR OTHER DEFECTS. CASTING CONCRETE SHALL CONFORM TO ASTM C94 FOR SEVERE FREEZE THAW EXPOSURE CLASS WITH A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI AND AIR CONTENT OF 6% ±1.5%. INDIVIDUAL FULL UNITS SHALL HAVE THE FOLLOWING NOMINAL VALUES (±): 46"Lx41"Wx18"H BOTTOM UNITS 46"Lx28"Wx18"H MIDDLE AND TOP UNITS UNITS SHALL BE CAST WITH 2 SHEAR KNOBS TO CREATE A 5± DEGREE FACE BATTER, AND A MINIMUM PEAK INTERLOCK SHEAR CAPACITY OF 6,500 LB/FT AT A MINIMUM NOMINAL LOAD OF 500 LB/FT AND MINIMUM ULTIMATE PEAK SHEAR CAPACITY OF 11,000 LB/FT. FACE TEXTURE AND COLOR TO BE DETERMINED BY THE OWNER. GRAVITY UNITS MUST BE APPROVED BY S&ME, INC. AND OWNER PRIOR TO CONSTRUCTION. 2.3 FILTER FABRIC - GEOTEXTILE FILTER FABRIC SHALL CONSIST OF NEEDLE PUNCHED NON -WOVEN POLYPROPYLENE MATERIAL WHICH MEETS THE AASHTO M 288-2000 CLASS 3 STRENGTH CRITERIA. IT SHALL ALSO HAVE A MAXIMUM AVERAGE ROLL VALUE OF 0.25 MM FOR ITS APPARENT OPENING SIZE AND PERMITIVITY OF AT LEAST 0.2/SEC. PRE -APPROVED NONWOVEN GEOTEXTILES INCLUDE GEOTEX 801 AND TC MIRAFI 180N, OR APPROVED EQUAL. 2.4 HIGH PERFORMANCE (HP) GEOTEXTILE (IF RQD FOR UNDERCUT/STABLIZATION) - HP GEOTEXTILE SHALL CONSIST OF HIGH TENACITY MONOFILAMENT POLYPROPYLENE YARNS, WOVEN AND RESISTANT TO BIOLOGICAL DEGRADATION AND NATURALLY OCCURRING CHEMICALS. THE HP GEOTEXTILE SHALL HAVE A MINIMUM ULTIMATE TENSILE STRENGTH OF 3200 LB/FT AND MINIMUM TENSILE STRENGTH AT 5% STRAIN OF 1500 LB/FT. PRE -APPROVED HP GEOTEXTILES INCLUDE TC MIRAFI HP 370 AND CARTHAGE MILLS FX-370MF, OR APPROVED EQUAL. 2.5 DRAINAGE/ LEVELING PAD AGGREGATE - SHALL MEET ASTM C-33 CRITERIA FOR SIZE NO. 57 STONE. DRAINAGE STONE SHALL BE COMPACTED WITH THE USE OF A VIBRATORY PLATE COMPACTOR. 2.6 DRAINAGE PIPE - DRAINAGE PIPE SHALL CONSIST OF 4-INCH DIAMETER SCHEDULE 40 PVC OR HDPE. 3.0 FOUNDATION AND EXCAVATION PRACTICES 3.1 THE CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTHS OF THE EXISTING BUILDING FOOTINGS BY MEASUREMENTS IN THE FIELD PRIOR TO EXCAVATION FOR THE WALLS. 3.2 CARE WILL BE NEEDED NOT TO UNDERMINE THE EXISTING BUILDINGS DURING CONSTRUCTION AND EXCAVATION. 3.3 THE CONTRACTOR SHALL EXCAVATE TO THE LINES AND GRADES SHOWN ON THE CONSTRUCTION DRAWINGS, EXCAVATIONS SHALL BE MAINTAINED IN ACCORDANCE WITH OSHA, STATE AND LOCAL REGULATIONS. TOP OF LEVELING PAD (BOTTOM OF WALL) SHALL BE INSTALLED WITHIN 1" OF ELEVATION 2175.5 FEET. 3.4 EXCAVATION SHOULD NOT OCCUR WITHIN AN IMAGINARY PLANE EXTENDING DOWNWARD AND OUTWARD FROM THE BOTTOM LEADING EDGE OF THE BUILDING'S FOOTINGS ON A 1:1 (HORIZONTAL TO VERTICAL) INCLINATION, AND PREFERABLY FURTHER. IF THIS ZONE MUST BE ENCROACHED UPON, THE AREA WILL NEED TO BE EVALUATED AND DETERMINED IF SHORING OR UNDERPINNING OF THE BUILDING IS NECESSARY. 3.5 SMALL AREAS CAN BE WORKED AND REMEDIATED AT A TIME, RATHER THAN EXPOSING THE ENTIRE LENGTH OF THE BUILDINGS/BUILDING FOUNDATIONS ALONG THE CREEK FOR THE DURATION OF CONSTRUCTION. 3.6 FOUNDATION AND RETAINED SOIL AREAS SHALL BE EVALUATED WITH HAND AUGER BORINGS, DCP TESTING AND/OR PROOFROLLING BY THE GEOTECHNICAL ENGINEER TO VERIFY THAT THE WALL AREA IS DIRECTLY UNDERLAIN BY SUITABLE BEARING MATERIALS TO SUPPORT THE RETAINING WALL SYSTEM. 3.7 UNDERCUTTING AND STABILIZATION USING CRUSHED STONE, GEOTEXTILE FABRIC AND/OR HP GEOTEXTILE COULD BE REQUIRED TO PROVIDE SUITABLE BEARING. THE REQUIREMENT FOR UNDERCUTTING AND/OR STABILIZATION SHALL BE AS DETERMINED BY THE GEOTECHNICAL ENGINEER. 3.8 DEWATERING WILL BE REQUIRED TO PERFORM NECESSARY UNDERCUTTING/STABILIZATION AND TO INSTALL THE LOWER PORTION OF THE WALL. DEWATERING MEANS AND METHODS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR WITH THE PROVISION THAT THE EXCAVATION IS KEPT DRY UNTIL CONSTRUCTION HAS ACHIEVED A SUITABLE LEVEL ABOVE GROUNDWATER. PERFORATED DRAINAGE PIPE PERFORATED DRAINAGE PIPE 4.0 LEVELING PAD PREPARATION AND CONSTRUCTION 4.1 THE LEVELING PAD SHALL BE CONSTRUCTED WITH COMPACTED CRUSHED AGGREGATE THAT MEETS THE CRITERIA IN SECTION 2.0. 4.2 THE LEVELING PAD SHALL BE AT LEAST 7 INCHES IN FRONT OF AND 12 INCHES BEHIND BOTTOM UNIT, AT LEAST 12 INCHES THICK AND COMPLETELY WRAPPED WITH GEOTEXTILE FILTER FABRIC. 4.3 THE LEVELING PAD SHALL BE CONSTRUCTED SO AS TO PROVIDE A LEVEL, HARD SURFACE UPON WHICH TO PLACE THE FIRST COURSE OF GRAVITY UNITS. 4.4 CRUSHED AGGREGATE USED FOR THE LEVELING PAD SHALL BE COMPACTED USING A VIBRATORY SLED TO THE SATISFACTION OF THE OWNER'S ENGINEER. 4.5 THE LEVELING PAD SHALL BE PREPARED TO ENSURE FULL CONTACT BETWEEN THE PAD AND THE FIRST COURSE OF GRAVITY UNITS. 5.0 WALL CONSTRUCTION 5.1 THE WALL SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE GRAVITY UNIT MANUFACTURER'S RECOMMENDATIONS AND THESE REQUIREMENTS. 5.2 THE DRAINAGE PIPE SHALL BE CONNECTED TO A SOLID COLLECTOR PIPE AND DISCHARGED THROUGH THE FACE OF THE WALL USING WEEP HOLES AS DETAILED ON SHEET R3. 5.3 INSTALL BACKFILL IN RETAINED ZONE IN COMPACTED LIFTS NO GREATER THAN 8 INCHES IN THICKNESS AND IN ACCORDANCE WITH THE REQUIREMENTS IN SECTION 6. 5.4 INSTALL DRAINAGE AGGREGATE IN 8 INCH LIFTS AND DENSIFY USING VIBRATORY EQUIPMENT. GEOTEXTILE FILTER FABRIC SHALL BE INSTALLED BETWEEN DRAINAGE AGGREGATE AND RETAINED BACKFILL. 6.0 SOIL COMPACTION 6.1 THE OWNER'S ENGINEER SHALL EVALUATE AND DOCUMENT COMPACTION OF BACKFILL IN THE RETAINED ZONE IN ACCORDANCE WITH THESE REQUIREMENTS. ALL FILL MATERIAL SHALL MEET THE REQUIREMENTS OF SECTION 2.0 AND SHALL BE PLACED IN MAXIMUM 8-INCH THICK LIFTS (LOOSE MEASURE) AND UNIFORMLY COMPACTED WITH APPROPRIATE COMPACTION EQUIPMENT TO AT LEAST 95 PERCENT OF THE STANDARD PROCTOR (ASTM D698) MAXIMUM DRY DENSITY AND WITHIN 3 PERCENT OF ITS OPTIMUM MOISTURE CONTENT. 6.2 HEAVY COMPACTION EQUIPMENT OR OTHER HEAVY CONSTRUCTION EQUIPMENT MAY NOT BE OPERATED WITHIN 3 FEET OF THE BACK OF THE GRAVITY UNITS. 6.3 WITHIN 3 FEET OF THE BACK OF THE GRAVITY UNITS, ONLY HAND -OPERATED COMPACTION MAY BE USED. 7.0 DRAINAGE AND EROSION PROTECTION 7.1 AT THE END OF EACH WORK DAY, THE CONTRACTOR SHALL GRADE THE SURFACE OF THE LAST LIFT OF RETAINED SOIL AWAY FROM THE WALL FACE AND COMPACT. 7.2 THE CONTRACTOR SHALL INSTALL TEMPORARY SOIL BERMS AND DRAINAGE DITCHES AS NECESSARY TO PREVENT THE SURFACE FLOW OF WATER TOWARD THE RETAINED SOIL ZONE. 7.3 THE PONDING OF WATER ABOVE OR WITHIN 20 FEET BEHIND THE RETAINED SOIL ZONE DURING OR AFTER WALL CONSTRUCTION SHALL NOT BE PERMITTED. 7.4 EROSION PROTECTION SHALL BE INSTALLED IN FRONT OF THE WALL TO PROTECT AGAINST SCOUR AND UNDERMINING OF THE RETAINING WALL SYSTEM. UNDERMINING COULD RESULT IN WALL FAILURE. 8.0 WALL DESIGN 8.1 THE DESIGN WAS PERFORMED IN ACCORDANCE WITH NCMA GUIDELINES FOR MODULAR WALL DESIGN BASED ON S&ME'S EXPERIENCE WITH SOILS COMMON TO THE ASHEVILLE, NORTH CAROLINA AREA AND SUBSURFACE DATA OBTAINED BY S&ME AT THE PROJECT SITE AND PRESENTED IN A REPORT ON SEPTEMBER 27, 2019. THE FOLLOWING DESIGN PROPERTIES USED FOR DESIGN SHALL BE VERIFIED PRIOR TO WALL CONSTRUCTION: 8.2 DESIGN SOIL PROPERTIES ZONE CYm RETAINED SOIL 30' 0 PSF 120 PCF FOUNDATION SOIL 26' 0 PSF 105 PCF LEVELING PAD 40° 0 PSF 105 PCF 8.3 DESIGN PARAMETERS FS SLIDING = 1.5 SF OVERTURNING = 2.0 SF BEARING = 2.0 8.4 EXTERNAL LOADING NONE 8.5 ADDITIONAL LOADS ANY UTILITIES SUCH AS LIGHT POLES, HAND RAILS, GUARDRAILS, OR DRAINAGE STRUCTURES TO BE INSTALLED IN THE VICINITY OF THE WALLS MUST BE DESIGNED AND CONSTRUCTED SO THAT THEY DO NOT ADD LATERAL FORCES TO BE RESISTED BY THE WALL SYSTEM. IN ADDITION, ANY EXCAVATION (I.E., INSTALLATION OF CONCRETE GUTTERS, SHRUB AND TREE PLANTING, ETC.) CONDUCTED IN THE VICINITY OF THE WALL MUST BE DONE WITHOUT DAMAGING THE WALL. PLEASE CONTACT THE WALL DESIGN ENGINEER IF THERE ARE ANY QUESTIONS. 9.0 ENGINEER INSPECTION 9.1 A LETTER FROM THE ON -SITE GEOTECHNICAL ENGINEER SHALL BE PROVIDED TO THE OWNER AND/OR OWNER'S REPRESENTATIVE STATING THAT THE FOUNDATION MATERIALS ARE ACCEPTABLE FOR WALL SUPPORT, AND THAT THE BACKFILL MATERIALS HAVE BEEN PROPERLY COMPACTED AND HAVE MET THESE SPECIFICATIONS. THIS LETTER SHALL BE SIGNED BY A REGISTERED ENGINEER IN NORTH CAROLINA. 44 BUCK SHOALS RD, SUITE C-3 ARDEN, NC 28704 (828)-687-9080 ENGINEERING FIRM LICENSE NUMBER: F-0176 O N 00 N w Q ~ Z � w 0 O J O ro Q' It Q M = U -17- =0 Z O H V Z H _O Z O a V � Ce V O � W LL Q G W LA tA Cn 0l0 Z N z J C0 � � Q v~i M U Lu Q w ~ 0 LU U O N Lu CO J w Co J E a > U = w m Q 0o LU a 2� TYPICAL LEVELING PAD STEP DETAIL 3 TYPICAL PVC DRAINAGE WEEP HOLE DETAIL R3 SCALE: Not to Scale R3 SCALE: Not to Scale - PROJECT NUMBER NOTE: Information provided by Others NOTES: 1. Weep hole to be field installed as shown. 2. See Elevations on Sheet R2 for locations (25' maximum 1441-19-021 center -to -center spacing). DRAWING NUMBER 3. Field adjust Weep Hole as required to provide 6"± to 8"± invert above finished grade. 4. Information provided by Others. R3 1 Ol Know what's below. Call before you dig. STABILIZED RIPRAP OUTLET SEE DETAIL SHEET C3.03 IMPERVIOUS DIKE (TYP.)- SEE DETAIL SHEET C3.03 CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. �� TREE / `\ SEDIMENT FILL E$ BAG \ SEE DETAIL SHEET\C3.03 ^� \ DEWATERING PUMJ? I LD \TYP.) � I a / \ L4 _ _ `vtNT TOE OF BANK I (TYP.) - I- - INV. 2174-1 40" - -_- WILLO a EXISTING STREAM C/L 27>s EXISTING TCE -'�_ 27)6 CMP BOTTOMLESS rcE - _ Z2� _ LNftVERT EXISTING CITY OF � / ASHEVILLE STORM �o / DRAINAGE EASEMENT / MB 1, PG 231 LIMITS OF / DISTURBANCE (TYP.) / TEMPORARY / CONSTRUCTION '�oi EASEMENT (TYP.) sow ICE/ 0001cf/ _TCE rslow C GRADING LEGEND 250.50 TOP & BOTTOM CURB ELEVATIONS 250.00 \TW=223.00 TOP OF WALL ELEVATION BW=213.00 BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) + 250.60 SPOT ELEVATION LID LID LIMITS OF DISTURBANCE WOODED AREA 250 MAJOR CONTOUR 252 MINOR CONTOUR 250 ______ EXISTING MAJOR CONTOUR 252______ EXISTING MINOR CONTOUR PROPOSED STREAM CENTERLINE BOULDER CROSS VANE CONSTRUCTED RIFFLE ie �F /A\� \lCF I �_ FILE - CLE - - _ H0! 2 LIMIT`S OF DISTURBANCE (TYP.) SEE CONSTRUCTION SEQUENCE NOTE #8 SHEET C3.00 (TYP.) 1 lCF / CREPE1 ' �- 179 \\ l -21 YRTL T` - -- �� \ BW = 2177.00.00 TEMPORARY GRAVEL\ a - �. CONSTRUCTION ENTRANCE ACCESS LOCATION. SET DETAIL SHEET C3.02 - \ A EROSION CONTROL LEGEND SILT FENCE OUTLET IMPERVIOUS DIKE -SF-SF-SF- SILT FENCE - TP - TP - TP - TREE PROTECTION FENCE STAGING AREA STOCKPILING AREA CONSTRUCTION ENTRANCE/EXIT TOTAL DISTURBED AREA = 0.22 AC. ray / TCF POTENTIAL STAGING AREA I - EADDITIONAL STAGING EAS ON SHEET 00) T EJ. t- \ _ TPF TEMPORARY �cE� \r STAGING/STOCKPILE AREA �CE� �L nF (TO BE ENCOMPASSED WITH a�. FLEXIBLE CLEANWATER \ DOUBLE ROW SILT FENCE) ` \ HOSE (TYP.) \ �\ 4A \ %\d \ EXISTING CONCRETE SIDEWALK TO BE REPLACED IN KIND. EXISTING 18" VCP SANITARY SEWER (TYP.) CONTRACTOR TO TAKE EXTRA PRECAUTION NOT TO DISTURB EXISTING SANITARY SEWER I IWITC !1C DDn OnCCn /`DA\/ITV I 1 j� J I I I ILj ^5 ~ 1 \ = 10 C Ld a z EXISTING 6" CPP 15'; INV. 2182.37SS , Y SS - __ _ � T BOULDER CROSS VANE (TYP.) ss - d� \ (o rcE SE DET L SHEET C8.00 z ' ice_ - �_ \ E 2 TW = 2181.00 I BW = 2179.00 BOULDERS ss �- Te (TYP.) L-��_- \ SSMH RIM 2181.81 O T INV. 2175.64 e5,7 `�.I 24 TC TCE-TCE-TCE-TC loll _ 1 ., HOLLY HOLLY -2181- - - 2+80 \ \ EXISTING 4" IRON --__ PIPE: TELEPHONE LINE TOP OF PIPE: CONCRETE T�j - ��- 01 2178.24 < TO BE _ 2.5" PLASTIC D IN KIND. CONDUIT: CABLE TW = 2183.00 TV LINE TW = 2183.00 BW = 2178.00 m TOP OF PIPE: BW = 2178.00 \ EXISTING PEBBLE I � \ � \ 2177.9 CREEK CONDOS TW = 2182.00 >�-$ FIFE = 2183.10 BW = 2179.00 EXISTING 6" PVC_ fMPERVIOUS DIKE INV. 2179.93TW _P ) _ - SEE DETAIL L BW = 21 PROPOSED STREAM C = 217 .00 / BW 79.00 L � SHEET C3.03 PROPOSED GRAVITY 2.5" PVC: POWER LINE RETAINING WALLS TOP OF PIPE: 2177.3 ce EXISTING 6" CPP PUMP AROUND 'a (SEE SHEETS R1 THRU R3) (INV. 2179.82 PUMP _ 2+83- 1 301 � 3CI1 3�1 �iJ CONTRACTOR TO TAKE EXTRA PRECAUTION I I HEC-RAS NOT TO DISTURB EXISTING UTILITIES CROSS-SECTION CROSSING DINGLE CREEK (TYP.) 14" 166.05 TEMPORARY CONSTRUCTION EASEMENT (TYP.) I N NC GRID (NAD83) GRAPHIC SCALE 0 5 10 20 1 inch = to ft. 'J McADAMS The John R. McAdams Company, Inc. 3430 Toringdon Way Suite 110 Charlotte, NC 28277 phone 704. 527. 0800 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CLIENT CITY OF ASHEVILLE, PUBLIC WORKS DEPT. 161 SOUTH CHARLOTTE STREET ASHEVILLE, NC 28801 PHONE: 828. 232. 4567. A THECITYOF ASHEVILLE Q (DUJI Uj W Z z� - , 00 O V) LU • a H Q p00 LIJ N z J oc U W-_0Qoff V m U Q z W Q Z TU 2 LLJ J J Co (%� 0 L U � Co O a W U am r-I ,,`,IIIIIIII/III CARD _y '•�� SEAL��� 049073 co 1111111 REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. COA-19000 FILENAME COA19000-G1 CHECKED BY RAS DRAWN BY KEG SCALE AS NOTED DATE 10.26.2020 SHEET GRADING & EROSION CONTROL PLAN C 601 FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION FORM OVERLOOK CIR PFeBI CRFEK OR � � • � \ �' \ . \.�•� LEGEND Q Project Area — — Streams — Roads 2-ft contours Upland Data Point UPLAND DATA POINT S1 (PERENNIAL) +/- 80 LF 0 25 50 FIGURE 4. JURISDICTIONAL AND ISOLATED WATERS DELINEATION MAP N Feet PEBBLE CREEK STREAM STABILIZATION 1 inch = 50 feet ASHEVILLE, BUNCOMBE COUNTY, NC VERSION: 1 DATE: 7/17/2020 McADAMS JOB NO: COA-19000 DRAWN BY: pierzga