Loading...
HomeMy WebLinkAbout20090859 Ver 1_More Info Letter_20101028& , L fn 12=a NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary October 28, 2010 DWQ# 09-0859v2 Stanly County Mr. Greg Simmons Charlotte Pipe and Foundry P. O. Box 35430 Charlotte, NC 28208 Subject Property: Oakmont Charlotte Pipe and Foundry REQUEST FOR MORE INFORMATION: STORMWA TER MANAGEMENT PLAN (SMP) Dear Mr. Simmons: On October 7, 2010, the 401/Wetlands Permitting Unit of the Division of Water Quality (DWQ) received a stormwater management plan (SMP) dated October 4, 2010 (Engineer's Seal) along with supporting information for the purpose of meeting the SMP condition (#5) of the 401 Water Quality Certification issued by the DWQ on August 27, 2009. Please provide the following information so that we may continue to review your project and prevent return of your application as required by 15A NCAC 2H.0506: Additional Information Requested: Wet Ponds: a. Please combine the two forebays in Pond #I into one, and relocate the outlet structure in order to elongate the flow path length. b. Please start accumulating the pond volume from the sediment clean out elevation. c. Please provide seasonal high water table (SHWT) information on the supplement form, and include a soil report in which the soil test borings are conducted at the pond locations. This information is pertinent to the permanent pool elevation. d. Please match the permanent pool volume for Pond #2 and the ballast pad dimensions of the outlet structures on the supplement form, the plan sheets and design calculations report. 2. Level Spreader - Vegetated Filter Strip (LS-VFS): a. The level spreader lip and footing shall be constructed of reinforced concrete material. b. Please follow the new design guidelines as summarized in Table 8-1 in the DWQ BMP Manual. LS-VFS used for different purposes have different design requirements. As discussed with your engineer, please use the available space, to the maximum extent practicable, to provide an acceptable length of level spreader for the type of filter strip and flow directed to it. c. Please include design information for the flow-splitting device - e..g amount of flow being diverted to the LS, the sizing of the pipes and determination of their invert elevations or any weir structure. d. Include construction notes for the LS-VFS 401 OversighUExpress Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 Location: 2321 Crabtree Blvd., Raleigh, North Carolina 27604 Phone: 919-733-17861 FAX: 919-733-6893 Internet: http:llh2o.enr.state.nc.uslncwetlands/ NorthCarolina Naturally An Equal Opportunity 1 Affirmative Action Employer Oakmont Charlotte Pipe and Foundry- SMP Stanly Page 2 of 2 October 28, 2010 Please respond by sending two (2) copies of the above information and any revisions in writing. This letter only addresses the application review and does not authorize any impacts to wetlands, waters or protected buffers. Please be advised that any impacts approved within your certification cannot occur until the SMP is approved. Thank you for your attention to this matter. If you have any questions or wish to discuss these matters further please do not hesitate to call Joseph Gyamfi at 919-733-1786. Si erely _ Ian McMillan, Acting Supervisor 401 Oversight/Express Review Program CBK/jg cc: File copy Alan Johnson - DWQ Mooresville Regional Office Matt Bramwell, PE, LandDesign, 223 North Graham Street, Charlotte, NC 28202