Loading...
HomeMy WebLinkAbout20100510 Ver 1_Triage Comments_20101019Use this form instead of writing inside the folder Triage Comment Sheet -6?0 DWQ# JO 0 Triaged By: Reviewer 1 Reviewer 2 Reviewer 3 Date: /Date: Date: ? Issue Project (Reviewer 1) ? Issue Project (Reviewer 2) Issue with conditions (Reviewer 1) N "'V Elam'-) RUtj I Issu ?t conditions (Reviewer 2) i7lilAiv) ? More Information (Reviewer 1) ? Return Application (Reviewer 1) ? Send to Regions (Reviewer 1) ? More Information (Reviewer 2) ? Return Application (Reviewer 2) ? Send to Regions (Reviewer 2) SATriage Forms\Triage Issue Sheet.doc PLEASE PRINT CLEARLY Lucas, Annette From: Lucas, Annette Sent: Tuesday, October 19, 2010 11:45 AM To: Chapman, Amy Cc: Lucas, Annette Subject: 10-0510 Chatham Co. Law Enforcement Parking Lot - RETURN Attachments: 10-0510 Chatham County Law Enforcement Center Parking Lot RETURN.docx Amy - I say return this one - they did a poor job in responding to the last RFMI. Let's chat about the issue of future development on the property. Thanks, Annette Annette Lucas, PE NC Division of Water Quality - 401 Oversight/Express Unit 2321 Crabtree Boulevard, Suite 250 Raleigh, North Carolina 27604 Phone: (919) 715-3425 Fax: (919) 733-6893 Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 10-0510 Chatham County Law Enforcement Center Parking Lot AML comments October 19, 2010 RETURN. A number of items that requested in the previous Request for More Information Letter were not provided in the submittal as follows: Item 1(a) stated: "The forebays of the proposed bioretention areas should be equipped with liners to prevent stormwater from seeping through the berm and passing directly to the underdrain system without appropriate treatment. Please provide a design for the northeastern forebay." The liner requirement for the forebay stands. Vegetation should not be planted in a forebay as it will interfere with regular maintenance activities. If you do not intend to provide a northeastern forebay, then it should not appear on the plans. The grading for the surface area of the forebay is shown on the plans; however, the plans do not show this area being filled with appropriate engineered soil media, equipped with underdrains, planted with appropriate plants, etc. 2. Item 1(b) stated: "The planting plan must show the actual location of the plants within the bioretention cell." This information was not adequately provided on Sheet C601. The planting plan provided on Sheet C600 for the balance of the site is a fairly good example of the type of specific planting information that the DWQ requires for the bioretention planting plan. The planting table for the bioretention area must show the names, size, and total number for each specified plant. 3. Item 1(e) stated: "The tree and shrub planting details should be modified to show one-half to one-third of the rootball above grade." The planting detail on sheet C600 do not show one-half to one third of the rootball above grade. 4. Item 1(g) stated. "A soil test to document the estimated elevation of the seasonal high water table must be provided." Documentation of a soil test was not provided. The response provided is not adequate. 5. Item 1(i) stated: "A signed and notarized Operation and Maintenance Agreement must be provided." The signed and notarized Operation and Maintenance Agreement was not provided. 6. Item 2 stated: "Please explain how the remaining undeveloped area on the north side of the property fronting US-64 will be utilized." If there is no intent to develop the remainder of the site at present, then all references to future development should be removed from the new application. In addition, the future forebay should be removed from the plans and the bioretention area design should show how the bioretention area to serve the current project will be designed.