HomeMy WebLinkAboutWQ0022725_Inspection_20201119ROY COOPER Governor MICHAEL S. REGAN Secretory S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality December 15, 2020 John F Zachwieja Slash Creek Condominium Homeowners Association PO Box 1465 Kitty Hawk, NC 27949 SUBJECT: Compliance Inspection Report Slash Creek WWTP Non -discharge Permit No. WQ0022725 Dare County Dear Mr. Zachwieja: The North Carolina Division of Water Resources conducted an inspection of the Slash Creek WWTP on 11/19/2020. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0022725. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Paul Mays with the Water Quality Regional Operations Section in the Washington Regional Office at 252-948-3940 or via email at paul.mays@ncdenr.gov. ATTACHMENTS Cc: Laserfiche Sincerely, P hails Paul Mays, Environmental Specialist 1 Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ID ra pans t t Erre r orm.,t q, - I D arsua aa Waterrsaso. Was^. rgt 5 8:ea Off., 194., heat rgn .ars Na 1 Was:Was^ rgtc.:. hxa Zara a Be.P& E4E1 Compliance Inspection Report Permit: WQ0022725 Effective: 11/07/17 SOC: County: Dare Region: Washington Effective: Expiration: 10/31/22 Owner : Slash Creek Condominium Homeowners Association Expiration: Facility: Slash Creek WWTP 57440 NC 12 Hatteras NC 27943 Contact Person: John F Zachwieja Title: Board President Phone: 252-261-1200 Directions to Facility: on the outer banks, take NC Highway 12 south of Buxton and Frisco and Slash Condos will be located on the right (sound side) of NC 12 as you enter the town of Hatteras System Classifications: SI, WW3., Primary ORC: David Pharr Certification: 21101 Phone: 252-473-3461 Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 11/19/2020 Primary Inspector: Paul M Mays Secondary Inspector(s): Entry Time 11:OOAM Reason for Inspection: Follow-up Permit Inspection Type: Reclaimed Water Facility Status: Compliant 0 Not Compliant Question Areas: ▪ Treatment Flow Measurement -Effluent ▪ Treatment Flow Measurement -Water Use Records N I Treatment Filters ▪ Treatment Sludge Storage/Treatment ▪ Treatment Disinfection ▪ Storage (See attachment summary) Exit Time: 12:30PM Phone: 252-948-3940 Inspection Type: Compliance Evaluation ▪ Treatment Flow Measurement -Influent 1111 Treatment ▪ Record Keeping ▪ End Use -Irrigation ▪ Treatment Flow Measurement Standby Power • Miscellaneous Questions ▪ Treatment Barscreen ▪ Treatment Activated Sludge ▪ Treatment Clarifiers 1111 Treatment Return pumps ▪ Coastal Requirements Page 1 of 7 Permit: WQ0022725 Owner - Facility: Slash Creek Condominium Homeowners Association Inspection Date: 11/19/2020 Inspection Type : Compliance Evaluation Reason for Visit: Follow-up Inspection Summary: On 11/19/2020 from 11:00am to 12:30pm, Paul Mays and Robert Tankard with the Division of Water Resources from the Washington Regional Office conducted an inspection of Slash Creek WWTP operating under permit#WQ0022725. The facility was found to be non -compliant with permit #WQ0022725. Below are the findings during the inspection: The backwash function via air scouring for the tertiary filter was not operational during the inspection. The backup generator was not operational and the "warning light" was on for the turbidity meter during the inspection. When the generator was further inspected the display on the generator pointed to an ignition fault. ORC David Phar stated the battery died the morning of the inspection. Michelle Pharr followed up with photo evidence that the generator, the turbidity meter, and backwash function of the tertiary filter are now fully operational. These photos are included in the report and docemented. The Turbidity meter was calibrated on 05/16/2020 Effluent flowmeter was calibrated on 05/01/2020 The 10' x 12' x 13' aeration basin appeared to be fully operation. However, the entire basin was covered with a thick foam. It was unknown what caused the foam layer to form on the basin. All records and reports requested for the inspection were available. Operation and maintenance records were available for review. Upon review of the 07/2020 NDMR discrepancies for total phosphorous, PH, TSS and DO were found between the report and the lab data. On 07/15/2020 PH was 7.46 for the NDMR and 7.46 from lab data, total phosphorous was 0.73mg/I and not found in lab data, TSS was 3.4mg/I in NDMR and 4.55mg/I from lab data and lastly, DO was 3.4mg/I in NDMR and 4.55mg/I in lab data. The 06/2020 NDMR was spot checked with no discrepancies. Michelle Pharr will be followed up with an amended 07/2020 NDMR and corresponding lab data. No discrepancies were found within the amended report. At the time of inspection many of the irrigation nozzles were not fully functional and did not irrigate properly. Due to this the specified acreage in the permit was not being irrigated. The irrigation nozzles require maintenance or fixing in order to correct this issue. Documentation has been provided showing that the irrigation system was fully functional after the inspection by Michelle Pharr. This documentation is included at the end of the report and documented. Page 2 of 7 Permit: WO0022725 Owner • Facility: Slash Creek Condominium Homeowners Association Inspection Date: 11/19/2020 Inspection Type : Compliance Evaluation Reason for Visit: Follow-up Type Yes No NA NE Lagoon Spray, LR ❑ Activated Sludge Spray, LR ❑ Single Family Drip ❑ Recycle/Reuse ❑ Infiltration System ❑ Single Family Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Reuse (Quality) Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Yes No NA NE • ❑ ❑ ❑ ❑ ❑ ❑ ❑ Comment: The backwash function for the tertian/ filter was not operational during the inspection. The backup generator was not operational and the "warning light" was on for the turbidity meter during the inspection. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Yes No NA NE ❑ ❑• ❑ ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ ❑ ❑•❑ Yes No NA NE ❑ ❑•❑ ❑ ❑•❑ Yes No NA NE • ❑ ❑ ❑ ■ ❑❑❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 3 of 7 Permit: WQ0022725 Owner - Facility:Slash Creek Condominium Homeowners Association Inspection Date: 11/19/2020 Inspection Type : Compliance Evaluation Reason for Visit: Follow-up Comment: The Turbidity meter was calibrated on 05/16/2020 Effluent flowmeter was calibrated on 05/01/2020 Standby Power Is automatically activated standby power available? Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Yes No NA NE • ❑ ❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The generator was not functional during inspection. When the generator was further inspected the display on the generator pointed to an ignition fault. ORC David Phar stated the battery died the morning of the inspection. Treatment Barscreen Is it free of excessive debris? Is disposal of screenings in compliance? Are the bars spaced properly? Is the unit in good condition? Comment: Treatment Activated Sludge Is the aeration mechanism operable? Is the aeration basin thoroughly mixed? Is the aeration equipment easily accessed? Is Dissolved Oxygen adequate? Are Settleometer results acceptable? Is activated sludge an acceptable color? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑• • ❑ ❑ ❑ ❑ ❑ ❑• Comment: The 10' x 12' x 13' aeration basin appeared to be fully operation. However, the entire basin was covered with a thick foam. It was unknown what caused the foam laver to form on the basin. Treatment Clarifiers Yes No NA NE Are the weirs level? ❑ ❑ ❑ Are the weirs free of solids and algae? •000 Is the scum removal system operational? • ❑ ❑ ❑ Is the scum removal system accessible? MEMO Is the sludge blanket at an acceptable level? ❑ ❑ ❑• Is the effluent from the clarifier free of excessive solids? • 000 Comment: Treatment Return pumps Are they in place? • Yes No NA NE ❑ ❑ ❑ Page 4 of 7 Permit: WO0022725 Owner - Facility: Slash Creek Condominium Homeowners Association Inspection Date: 11/19/2020 Inspection Type : Compliance Evaluation Reason for Visit: Follow-up Are they operational? Comment: Treatment Filters Is the filter media present? Is the filter media the correct size and type? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids? Is the mud well free of excessive solids and filter media? Does backwashing frequency appear adequate? • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ❑ ❑ ❑• ❑ • ❑ ❑ ❑•❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑•❑ ❑ Comment: The backwash function via air scouring for the tertiary filter was not operational during the inspection. Treatment Sludge Storage/Treatment Is the aeration operational? Is the aeration pattern even? If required, are Sanitary "Ts" present in tankage? Comment: Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑■❑ • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ • ❑■❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ ❑ ❑•❑ Page 5 of 7 Permit: WQ0022725 Owner - Facility: Slash Creek Condominium Homeowners Association Inspection Date: 11/19/2020 Inspection Type : Compliance Evaluation Reason for Visit: Follow-up Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? No treatment units bypassed since last inspection? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑❑❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ ❑ ❑•❑ O 0110 ❑ ❑ • ❑ ❑ 01E0 ❑ ❑•❑ ❑ ❑•❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑•❑ ❑ ❑ ❑•❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑•❑ • ❑ ❑ ❑ Comment: All records and reports requested for the inspection were available. Operation and maintenance records were available for review. Upon review of the 07/2020 NDMR discrepancies for total phosphorous, PH, TSS and DO were found between the report and the lab data. On 07/15/2020 PH was 7.46 for the NDMR and 7.46 from lab data, total phosphorous was 0.73mq/I and not found in lab data, TSS was 3.4mq/I in NDMR and 4.55mq/I from lab data and lastly, DO was 3.4mq/I in NDMR and 4.55mq/I in lab data. The 06/2020 NDMR was spot checked with no discrepancies. End Use -Irrigation Are buffers adequate? Is the cover crop type specified in permit? Is the crop cover acceptable? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 6 of 7 Permit: WQ0022725 Inspection Date: 11/19/2020 Owner - Facility:Slash Creek Condominium Homeowners Association Inspection Type : Compliance Evaluation Reason for Visit: Follow-up Is the site condition adequate? Is the site free of runoff / ponding? Is the acreage specified in the permit being utilized? Is the application equipment present? Is the application equipment operational? Is the disposal field free of limiting slopes? Is access restricted and/or signs posted during active site use? Are any supply wells within the CB? Are any supply wells within 250' of the CB? How close is the closest water supply well? Is municipal water available in the area? # Info only: Does the permit call for monitoring wells? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Are monitoring wells damaged? ■ ❑❑❑ . ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ ❑ ■❑❑ • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑•❑ ❑ ❑•❑ O 0110 • ❑ ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ O E11110 ❑ ❑ • ❑ Comment: At the time of inspection many of the irrigation nozzles were not fully functional and did not irrigate properly. Due to this the specified acreage was not being irrigated. The irrigation nozzles require maintenance or fixing in order to correct this issue. Coastal Requirements Are essential treatment units provided in duplicate? Is an adequately sized aerated equalization basin present? If so, is it operable? If present, are diffusers cleaned regularly? Is the equalization capacity adequate? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ 111000 ❑ ❑•❑ • ❑ ❑ ❑ Page 7 of 7 A �� SCou( t Scouc Aic 5ux)( AIR SCOUR BLOWER HAND OFF AUTO AIRSCOUR NO.1 HAND OFF AUTO NI( Scovc Uem«k(T 1 G-C (\ec ()Oro( 2 • 3'411 J.1 ALARM /UARM 2 TO Tucb-lay 1 vc b-icli-\ 1 (External) Slash Creek Irrigation System micheltedPob h2otom In 0 Met; Pau4M Os mire Ili Now a si min now ms ow naps a auplataammnce towewnIn a was Women e') Reply 01 Reply Pll -i Seward w. Tw 124,7020 biiahl [utmost. blarnelarnalt Co not sect links o open ahacMnemsunlau you verify. fend al aurpkbusamaa as m attachment to Rese.tl w December 8, 2020 To: Paul Mays DENR From: Michelle Pharr aibemad. Environmental Reference: Slash Creek Irrigation System Dear Mr. Mays, Per your request, as faltow up to the November 19, 2020 Slash Creek impaction, I am providing you with written documentation of the noidng status of the Slash Creek Irrigation System. There are 16 spray irrigation acmes, 1,2,5.6,7,8,9,10,11,12,13,14,15,16,17,18, with B to 10 spray IrrlgaUon nozzles per zone. Post Inspection, all zones ware chocked and ab nozzles are working. Than have boon 5 spray nozzles Identified, when activated, are not consistent with their spray pattern. The owners have now winterized the Irrigation system. We will work on the nozzles that have Irregular spray performance In the spring when the krigatfon system Is Initialized. Best regards, Michelle Pharr