HomeMy WebLinkAboutNC0081931_Meter Calibration - CEI_20201209Strickland, Bev From: Tommy Gibson <Tommy.Gibson@eaglecreekre.com> Sent: Wednesday, December 9, 2020 1:15 PM To: Scheller, Roberto Cc: Jeff Henley; Paul Tran Subject: [External] Cube Hydro pH Meter Temperature Calibration Attachments: I MG_20190919_0001.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Roberto, During the Cube Hydro inspection today you identified the need for annual temperature calibration of the pH meter. We confirmed that we did send the meter out for temperature calibration last year. Attached is the calibration certification. Thanks for identifying this requirement for us going forward. Tommy Date Received:,t1?nr1 Work OrderNo: W Gustomer:QqQe Hydro Contact:Phillip Poplin Phone No:704 4225531 Email: Purchase Order No:Job No: Data:Certificate Required:Yes No Yes No Service Type:Calibntion Repai Estimate Sares Other Area:Electrical Pressure Temperature Toryue Physhal Dimensional I Otner ll/lethod Received:UPS Method Returned:UPS Description: Mfr: Mode! S/N: rest Date: -9{1911-e_______ Due Date: 9118120 Total ltems Received:1 Gondition Received:SAT Gondition Returned:SAT 3urrent Status:Special Calibration (.1 ) Fees: Service Type Calibration $90 Repair $ Pafts $ Shiooinq & Handlino UPS Ground c 20.43 Other / Miscetlaneous $ TOTAL AMOUNT DUE $110.43 Pavment Tvpe:trNVorcE I Received By: Name: f2) Date: Shipping Detail: Couier Type Trackinq No(s) UPS 12223 055 03 9210 1523 Customer lnstructions:Certiff Temperature function only Remarks:(*1) Temperature is only function certified _ (.2 c/o: Phillip Poplin 293 HWY 740 _ Badin, NC 28009 lnvoice To:9EL Attn: Keith Mccollock INVOICE 4250 Meeting St N, Charleston, SC Parker lnstrument Co., lnc. Phone: U3747 5497 Email : parkerinstrument@outlook.eom REMITTO: POBOX72187 N. Charleston, SC 29415 GEoRGEPARKER 2 LBS 1 OF 1e43 747 5097PARKER INSTRUMENTs .ARTH DR. Dwr: 12,9,6CHARLESTON SC29414SHIP TO:PHILLIP POPLIN704 422 553LCUBE FTYDRO2% ffVW 740BADIN NC 28009NC 281 4-01lilllililIliltiltlllUPS GROI.'NDTRACICNG #: \2223 055 03 92LO 1523|Itilililililililil|l1ililil|il|B]LL]NG: P/PReference #l:152O2a7/zo7s EE,, Gertificate of Calibration Parker lnstrument Traceable to NIST IAW ISO-9002 Certificate No: Customer: Device Under Test (DUT): Manufacturer: Model No: S/N: Test Date: Due Date: Condition Received: Gondition Returned: Current Status: Galibration Procedure No: Test Equipment Used: Approved Date: Remarks: 15202 Cube Hydro pH / ORP Meter Yokogawa PH72 E006960 9t18t2019 9t18t2020 SAT SAT Limited-Use Galibration (*1) NAVAIR 17-20ST-03 & Mfr. Specs. HP, DMM, 34401A, #3146A03646 (US36087489), NIST# 1686318J-12/14l18 Leeds & Northrup, Platinum Resistance Thermometer, Model 8163 lce Bath Water Bath only function certified per this certificate Certified via 2-Point Method lce Bath (-0.032 Deg C) Water Bath (21.882 Deg C) Maximum error denoted during calibration was (+l- 0.2 Deg C) The item represented via this certificate has been calibrated in conformance with ANSI 2540.1 . This certiticate is neither a contract or contractual representation. Parker lnstrument's responsrbilities shall in no event exceed the cost of the seruice performed. We ceftity that the equipment listed on this certificate meets or exceeds all published specifications and has been calibrated using standards which are traceable fo MS7. The accuracies invoked on the equipment listed herein are with those which are specified either by the manufacturer or NAVAIR quidelines and has been calibrated using accepted values of natural physical constants or by the ratio-type of se lf-ca I i b ratio n tech n iq ue s. Phone:843747 5097 FAXr 843 747 23654250 Meeting SL Rd. N. Charleston, SC 29405 P.a.Box72187 N- Gharleston, SC 29415