Loading...
HomeMy WebLinkAboutWQ0004972_Permit Issuance_19860609S 4J0 \ State of North Carolina Department of Natural Resources and Community Development Division of Environmental Management 512 North Salisbury Street • Ralegh, North Carolina 27611 James G. Martin, Governor R. Paul Wilms S. Thomas Rhodes, Secretary Director June 9., 1986 Mr. Ulf Riser, Territorial Director Construction and Engineering Thousand Trails Resorts,Inc. 10250 Alliance Road Cincinnati, Ohio 45242 SUBJECT: Permit No. 13241 Thousand Trails Resorts,Inc. Forest Lake Preserve . Wastewater Collection Treatment and Spray Irrigation Disposal Facilities' Davie County Dear Mr. Riser: In accordance with your application received December 6, 1985, we are forwarding herewith Permit No.13241 dated June 9, 1986, to Thousand Trails Resorts, Inc. for the construction and operation of the subject wastewater collection, treatment and non - discharge disposal facilities. This permit shall be effective from the date of issuance until May 31,1991, and shall be subject to the conditions and limitations as -specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter.150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, Post Office Drawer 11666, Raleigh North Carolina 27604. If you wish to have the hearing before the Hearing Officer with this Department, you must indicate in the petition that you waive the right to have the contested case conducted by a Hearing Officer in the office of Administrative Hearings, and wish to have the matter conducted in the Department of Natural Resources • and Community Development. Unless such demands are made this permit shall be final and binding. Pbllution Prene dm Pays PO Box 27687, Raleigh. North (Carolina 27611-7687 Telcphone 919-733 7015 An Equal opportunity Affirmative Action Employer • Please be aware that any future transfer of ownership and maintenance responsibility for these facilities must be approved by this Division by.requesting permit reissuance, since this permit is non -transferable. One (1) set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Mr. Robert Teulings, telephone No. 919/733-5083, ext. 121. r Sinc ely yours, . Paul Wilms�� cc: Davie County Health Department. Winston-Salem Regional Supervisor Groundwater Section Z Dennis R. Ramsey • i • NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF NATURAL RESOURCES AND COMMUNITY DEVELOPMENT RALE I GH PERMIT For the Discharge of Sewage, Industrial Wastes, or Other Wastes In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED .TO Thousand Trails Resorts, Inc. Davie County FOR THE replacement of four (4) of seven existing pump stations in camping Areas A,B,C and D with new grinder pumps stations and operation of the existing sewer collection system serving 200 camp sites and 18 cabins; construction and operation of additional sewer . facilities to serve 83 new -camp sites in Area-D, said additions consisting of approximately 4,044 lineal feet of 6-inch gravity sewer with 4-inch laterals to each camp site, a 6 GPM grinder pump station with dual pumps and high-water alarm, and a 32 GPM grinder pump station with dual pumps and high-water alarm; modification of existing septic tanks and/or addition of new auxilliary tanks at each pump station in Areas A,B,C and D to provide emergency wastewater storage capacity; construction and operation of approximately 430 lineal feet of 3-inch force main, 455 lineal feet of 4-inch force main, and 935 lineal feet of 6-inch force main; and construction and operation of a 45,000 GPD extended aeration wastewater treatment facility with effluent storage lagoon and spray irrigation disposal system, said facilities consisting.of a 14,800 gallon capacity aerated surge tank with influent bar screen, dual 74 GPM submersible pumps, and high-water alarm, a 45,000 gallon capacity aeration tank, dual 285 CFM blowers, a 4500 gallon sludge holding tank, a 7500 gallon clarifier, a 940 gallon baffled chlorine contact tank with hypochlori- nator, a 0.408 14G capacity lagoon with PVC liner for storage of treated effluent, and dual 142 CPM effluent dosing pumps discharging to a 9-acre spray irrigation field with thirty (30) sprinkler heads with no discharge of treated wastewater to the surface waters of the State. pursuant to the application received December 6, 1985, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Natural Resources and Community Development and con- sidered a part of this permit. This permit shall be effective from the date of issuance until May 31; 1991; - • and shall be subject to the following specified conditions and limitations: j_ 1. This permit shall become voidable unless the facilities are constructed in accordance with the approved plans,. specifications and other supporting data. S Permit No. 13241 Page 2 • 2, Construction of the sewers shag: be scheduled so as not to interrupt service by the existing utilities nor result .n an overflow or bypass discharge of wastewater to the surface waters of the State. 3. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The facilities shall be properly maintained and operated at all times. 5. The sewage and wastewater collected by this system shall be adequately treated in the Thousand Trails' Forest Lake Preserve Wastewater Treatment Plant prior to being sprayed into the irrigation field. 6. This permit is not transferable. 7. The Permittee shall provide for the pump stations and force mains the following items: a. Pump-on/pump-off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station. h. An air relief valve located at all high points along the force main. c. A screened vent for the wet well. • d. Fillets located in the wet well at the- intersection of. the flooring and y sidewalls. e. Three (3) feet of cover (minimum) over the force main or the use of ferrous material where three (3) feet cannot be maintained. f. Sufficient devices which will protect the pump station from vandals. g. Flood protection if the pump station is located below the 100-year flood elevation. 8. The spray irrigation system shall be effectively maintained and operated at all times so that there is no discharge to the surface waters, nor any contamination of ground waters which will render them unsatisfactory for normal use. In event the facilities fail to perform satisfactory, including the creation of nuisance conditions, or failure of the irrigation area to adequately absorb the wastewater, the permittee, shall take such immediate corrective action as may be required by the Division of Environmental Management. 9. The Winston-Salem Regional Office, telephone number 919/761-2351, shall be notified at least twenty-four (24) hours in advance of start-up of the installed wastewater treatment and disposal facilities so that an inspection can be made of said facilities prior to operation. Such notification to the Regional Supervisor shall be made during normal office hours from 8:00 a.m.' until 5:00 p.m. on Monday through Friday, excluding State Holidays. 10. The sludge generated from these treatment facilities must be disposed of in Vermit No. 1'241 Page 3 0 • accordance with General Statute 143.215.1 and in a manner approvable by the North Carolina Division of Environmental Management. 11. The Permittee shall employ a certified wastewater treatment plant operator in responsible charge of the wastewater treatment facilities. Such operator must hold a certificate of the grade at least equivalent to the classification assigned to the wastewater treatment facilities by the Certification Commission. 12. Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause runoff. 13. Dikes shall be constructed so as to prevent surface water runoff from the spray field. 14. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited. 15. A suitable year round vegetative cover shall be maintained on the spray irrigation field: 15. The wastewater application rates shall not exceed: (a) 0.9 inch/acre/week (b) 0.11 inch/hour during dosing (c) the treated wastewater shall be uniformly applied to avoid runoff, ponding or erosion. 17. Freeboard in the treated wastewater storage lagoon shall not be less than one (1) foot at any time. 18. The issuance of this permit shall not relieve Thousand Trails, Inc. of the responsibility for damages to surface or ground waters resulting from the operation of this facility. 19. The facilities shall be effectively maintained and operated as a non --discharge system to prevent the discharge of any wastewater into the surface waters of the State. 20. No type of wastewater other than that from the Thousand Trails, Inc. Forest Lake Preserve shall be sprayed onto the irrigation area. 21. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while normal maintenance is being performed. 22. The wastewater treatment and disposal facilities -.shall be above the 100—year flood elevation. 23. Any monitoring deemed necessary by the Division of Environmental Management -to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 24. Monitoring wells shall be constructed and sampling schedules arranged as required by the Division of Environmental Management and constructed in accordance with 10 NCAC 2C 0.100. Permit No. 13241 Page 4 . (a) Within 90 days of permit issuance, four (4) monitoring wells (one upgradient and three downgradient) shall be installed to monitor groundwater quality. The location and construction details for these wells shall be by approval of the Division's Wiziston-Salem Regional Office, from which a well construction permit must be obtained. Note: The four wells may include existing wells GW3 and GW5, previously installed by Law Engineering Testing Company, provided that the spray pattern can be adjusted so that an adequate buffer zone (as determined by the Winston-Salem Regional Office) is provided between the spray field and that Well GW5 is deepened to reach the water table. (b) The groundwater monitoring wells shall be sampled initially after construction (and prior to waste disposal operations) and thereafter every March, July, and November for the following parameters: NO ToLl Ammonia Total Dissolved Solids pH Total Organic Carbon Chloride Total Coliforms Water Levels The measurement of water level shall be made prior to sampling for the remaining parameters. (c) Any additional groundwater monitoring deemed necessary by the Division shall be provided. • 25. The Permittee, at least six (6) months prior to the expiration.of this Permit, shall request its extension. Upon receipt of the request, the Commission will review the adequacy of the facilities described therein and if indicated, will extend the Permit for such period of time and under such conditions and limitations as it may deem appropriate. Permit issued this the 9th day of ,tune, 1986. Permit No. 13241 • NORTH CAROLINA ENVIRONMENTAL MANAGEI-1ENT COMMISSION R. Paul Wilms, Director I--- Division of Environmental Management By Authority of the Environmental Management Commission