HomeMy WebLinkAboutSW6201201_Storm outlet_20201210ATE DESIGN PHASE 1-11-20 PRELIMECT NAME FLOCATION PROJECT NO CONSTR / XLine Brewe 1641 REVISION RECORD BY Harnett County, North Carolina UP OTHER (SPECIFY) CHECKED BY CSB Flume typical (Max Flow) FES No.= Flume Pipe Dia= 24 in Q10 = 2.30 cfs Qfull = 2.30 cfs Vfull = 2.36 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: t 3 Length Storm Outlet Structure FES No.= FES 1 Pipe Dia= 30 in Q10 = 62.71 cfs Qfull = 65.77 cfs Vfull = 13.38 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: Zone D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Zone D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Q10/Qfull = 1.00 V/Vfu I = 1.14 V = 2.7 fps = 1 = 4 in = 6 in = A = 9 in = 8.0 ft = 6 ft = 10.0 ft Q10/Qfull = 0.95 V/Vfu I = 1.14 V = 15.2 fps = 2 = 8 in = 12 in = B = 18 in = 15.0 ft = 7.5 ft = 17.5 ft 1641 Storm.xlsx LATEST REVISION: 12/10/2020 3:44 PM PAGE 1 OF 2 • ` DATE DESIGN PHASE 1-11-20 PRELIMME rPROJECT PROJECT NO CONSTR / Xwe 1641 REVISION RECORD BY Harnett County, North Carolina UP OTHER (SPECIFY) CHECKED BY CSB Storm Outlet Structure FES No.= FES 3 Pipe Dia= 36 in Q10 = 45.17 cfs Qfull = 142.71 cfs Vfull = 20.16 fps From Fig. 8.06.b.1: Zone From Fig. 8.06.b.2: L v 3 Length Q10/QfuI1 = 0.32 V/Vfu11 = 0.87 V = 17.6 fps = 2 D50 = 8 in DMAX = 12 in Riprap Class = B Apron Thickness = 18 in Apron Length = 18.0 ft Apron Width @ Outlet = 9 ft Apron Width @ End = 21.0 ft 1641 Storm.xlsx LATEST REVISION: 12/10/2020 3:44 PM PAGE 2 OF 2