Loading...
HomeMy WebLinkAboutWI0700087_Inspection_20201209North Carolina Department of Environment and Natural Resources Division of Water Quality — Aquifer Protection Section INJECTION FACILITY INSPECTION REPORT PERMIT NO. WI0700087 DATE OF INSPECTION: 12/9/20 INSPECTOR: R. Sipe NAME OF PERMITTEE(S) Ashton Lewis Lumber MAILING ADDRESS OF PERMITTEE PO Box 25, Gatesville, NC 27938 PHYSICAL ADDRESS OF SITE (if different than above) Lewis Mill Rd., Gatesville, NC 27938 PERSON MET WITH ON -SITE Michael Lancaster; TELE NO. (252)357-0050 WELL(S) STATUS: XExisting and operating Class V Well Existing well proposed to be converted to Class V well Proposed/not constructed LAT/LONG OF WELL(S) Well #1 (Supply Well): 36.397778N; 76.767222W Well #2 (Inj. Well):36.398056N; 76.7675W Appx. distance of well to property boundaries: _200 feet (Well #1- Supply); 60 feet (Well 42-Inj.) Appx. distance of well from foundation of house/structure: _15 feet (both wells) Appx. distance of well from septic tank/field (if present): _400 feet (Well #1- Supply): 450 feet (Well 92-Inj.) Appx. distance of well to other well(s) (if present) Appx. distance to other sources of pollution: _None 150 feet between Well 91 and Well 92 Flooding Potential of Site: high moderate Xlow Comments: This system is designed so that the two wells can be interchangeably be used for either supply or injection. Both wells appear to be in good condition consistent with findings of prior inspection and operating adequately. Injection Facility Insp. Report (Rev. Sept 2009) Page I of 4 Pages See Attached Map DRAW SKETCH OF SITE ABOVE (Show property boundaries, buildings, other wells, septic tanks/drain fields, other potential pollution sources, roads, approximate scale, and NORTH arrow) Well construction information was provided with the last inspection report. There have not been any changes in well construction since that time. Draw Schematic of well above showing TD, casing depth, grout, etc. Injection Facility Insp. Report (Rev. Sept 2009) Page 2 of 4 Pages Well Construction Information Date Constructed: Well #1 (9/19/05); Well #2 (9/16/05)_ Well Contracting Company: _Magette Well and Pump Co., Inc. Well Driller Name: _Bobby Harrell NC Well Cert. No.: 2936-A Address:_2342 US Hwy 13 South, Ahoskie, NC 27910 Telephone No.: _(252)332-2265 ; Cell No.: Email Address: Proposed Depth of Well(s): _N/A Total Depth: _331 feet (Well #2) 346 Feet (Well 41)_ Casing: Depth: 315 feet (Well 92); 321 (Well 41); Diameter: 4 inches Type: PVC; Stick Up: 3 feet. Grout Depth: 0 - 20 feet (both wells); Type Cement; Placement: Pumping. Depth: 20 - 285 feet (Well 92); 20 — 300 feet (Well 41); Type Bentonite; Placement: Pumping Well ID Plate Present (Y or N): N ;Heat Pump ID plate present (Y or N): N Influent spigot (Y or N): Y Effluent spigot (Y or N): Y Well Sampled? (Y or N): N ; If Yes, Lab Sample ID numbers: Static Water Level: not measured Injection Information (if applicable): Injection Rate: GPM Injection Pressure: PSI Injection Volume: GPD Temperature- Summer: F° Temperature- Winter: F° Comments/Notes: This system is designed so that the two wells can be interchangeably be used for either supply or injection. Both wells appear to be in good condition consistent with findings of prior inspection and operating adequately. The wells were not sampled due to the current sample submittal restrictions at the DWR Central Lab. Samples may be collected at a later date when these restrictions are lifted. Injection Facility Insp. Report (Rev. Sept 2009) Page 3 of 4 Pages �-O \'V-• a 'r Injection Facility Insp. Report (Rev. Sept 2009) Page 4 of 4 Pages