Loading...
HomeMy WebLinkAboutNCS000115_DMR_20201203 SCANNED Date: November 20,2020 DEC 1 0 2020 I Novozymes,NA Inc. ' I� 77 Perry's Chapel Church Rd. novozymese Franklinton,N.C. 27525 Rethink Tomorrow NC DEQ Division Of Water Quality 1617 Mail Service Center Raleigh,N.C.27699-1617 RECEIVED Attn:Division Of Water Quality DEC 0 R 2020 DENR-LAND QUALITY Storm Water Sampling, NPDES Permit No. NCS000115 STORMWATER PERMITTING Dear Sir/Madam Per our Tier Two requirements,regarding the exceeded benchmark in Biochemical Oxygen Demand (BOD),our implementation of monthly monitoring in area of concern,"Outfall 2",beginning in October has resulted in the first of three being within required benchmark range. Test results from November mark the first month that our BOD reading has been within benchmark range.With November's testing complete,we will collect samples again from Outfall 2 for BOD until three consecutive sample results are within required benchmark range. Testing,sampling,will resume in December. Kind Re rds /a-71, Joe Lad/1 Environmental Compliance Coordinator Environmental Services t T ENCO Laboratories Accurate. Timely. Responsive. innovative. 102-A Woodwinds Industrial Court Cary NC,27511 Phone: 919.467.3090 FAX: 919.467.3515 Wednesday, November 18, 2020 Novozymes North America (N0008) Attn: Joe Ladd 77 Perry Chapel Church Road Franklinton, NC 27525 RE: Laboratory Results for Project Number: [none], Project Name/Desc: Stormwater CA ENCO Workorder(s):CD16099 Dear Joe Ladd, Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, November 12, 2020. Unless otherwise noted in an attached project narrative,all samples were received in acceptable condition and processed in accordance with the referenced methods/procedures. Results for these procedures apply only to the samples as submitted. The analytical results contained in this report are in compliance with NELAC standards, except as noted in the project narrative if applicable. This report shall not be reproduced except in full,without the written approval of the Laboratory. This report contains only those analyses performed by Environmental Conservation Laboratories. Unless otherwise noted, all analyses were performed at ENCO Cary. Data from outside organizations will be reported under separate cover. If you have any questions or require further information, please do not hesitate to contact me. Sincerely, S./(4 .2(1 Chuck Smith Project Manager Enclosure(s) FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 1 of 7 I ( 1 - '- : zcID) www.encolabs.com SAMPLE SUMMARY/LABORATORY CHRONICLE Client ID: Outfall-2 Lab ID: CD16099-01 Sampled: 11/11/20 13:30 1 Received: 11/12/20 09:35 Parameter preparation Hold Date/Time(s) preo Date/Time(sl Analysis Date/Time(sl SM 5210 B-2011 NO PREP 11/13/20 13:30 11/12/20 10:58 11/12/20 10:58 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 2 of 7 t 1 (EiJGD) www.encolabs.com SAMPLE DETECTION SUMMARY 1 Client ID: Outfall-2 Lab ID: CD16099-01 lAnalvte Results Flaq MDL Q Units Method Notes Biochemical Oxygen Demand 8.1 2.0 2.0 mg/L SM 5210 B-2011 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 3 of 7 s C 1 ..._ _ 90) www.encolabs.com ANALYTICAL RESULTS 1 Description: Outfall-2 Lab Sample ID:CD16099-01 Received: 11/12/20 09:35 Matrix: Surface Water Sampled:11/11/20 13:30 Work Order:CD16099 Project: Stormwater CA Sampled By:Joe Ladd Classical Chemistry Parameters ^-ENCO Cary rectified analyte[NC 591.1 Analvte ['CAS Numberl Results floe 'Pits DF MIA Mk Batch Method Analyzed Ix Notes Biochemical Oxygen Demand^ 8.1 mg/L 1 2.0 2.0 0K12011 SM 5210 B-2011 11/12/20 10:58 JOC FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 4 of 7 y C . _4= (m) www.encolabs.com QUALITY CONTROL DATA Classical Chemistry Parameters-Quality Control 1II Batch OK12011-NO PREP Blank(0K12011-BLK1) Prepared&Analyzed:11/12/2020 10:58II Spike Source %REC RPD Analvte Result Etas POL Units Level Result %REC its RPD Limit Notes Biochemical Oxygen Demand 2.0 U 2.0 mg/L LCS(0K12011-BS1) Prepared&Analyzed:11/12/2020 10:58 Spike Source %REC RPD Analvte Result nag FAA. Units Level Result %REC Jests RPD Lim' Notes Biochemical Oxygen Demand 200 2.0 mg/L 198 100 85-115 _Duplicate(0K12011-DUP1) Prepared&Anaiyzed:11/12/2020 10:58II Source:CD11261-01 Spike Source %REC RPD Analvte Result Flan nits Level Result %REC Limits RPD Lim it Notes Biochemical Oxygen Demand 51 2.0 mg/L 51 0.8 30 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 5 of 7 c;) www.encolabs.com FLAGS/NOTES AND DEFINITIONS � 1 B The analyte was detected in the associated method blank. D The sample was analyzed at dilution. J The reported value is between the laboratory method detection limit(MDL)and the laboratory method reporting limit(MRL),adjusted for actual sample preparation data and moisture content,where applicable. U The analyte was analyzed for but not detected to the level shown,adjusted for actual sample preparation data and moisture content,where applicable. E The concentration indicated for this analyte is an estimated value above the calibration range of the instrument.This value is considered an estimate. MRL Method Reporting Limit.The MRL is roughly equivalent to the practical quantitation limit(PQL)and is based on the low point of the calibration curve,when applicable,sample preparation factor,dilution factor,and,in the case of soil samples, moisture content. PQL PQL: Practical Quantitation Limit. The PQL presented is the laboratory MRL. N The analysis indicates the presence of an analyte for which there is presumptive evidence(85%or greater confidence)to make a"tentative identification". P Greater than 25%concentration difference was observed between the primary and secondary GC column. The lower concentration is reported. [CALC] Calculated analyte-MDL/MRL reported to the highest reporting limit of the component analyses. FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 6 of 7 4810 ��� ., . O) 10775 FL Central Port Dr. Executive Park Court.Suite 111 102-Ary, Woodwinds Induslnal Ct. Orlando.FL 32824 Jacksonville.FL 32216-6069 Cary,NC 27511 (407)826-5314 Fax(407)850-6945 (904)296-3007 Fox( )296-6210 (919)467-3090 Fax(919)467-3515 Page of Client Name Project Number Re quested Analyses Requested Turnaround Novozymes North America(N 0008.) [nonel - Times Address Project NamelDesc ..ter^-W1 Note:Rush requests subject to 77 Perry Chapel Church Road Stony nave acceptance by the facility CitylST/Zio - PO I/Billing Into Franklinton,NC 27525 3800467045 m Standard Tel Fax Reporting Contact G r 494-3370 Joe Ladd Cs1 _ Expedited LO Sameler(s)Name.Affiliation(Pont) Billing Contact --Sat_ , `.�7YNceS Accounts Payable V) Due / / Sampler) )Signa(2; , / SiteTAM-LI Time Zone — - O Lab Workorder ltw CD16099 Preservation(See Codes)(Combine as necessary) Collection Matrix Total N of Item a Sample ID(Field Identification) Collection Date Time Corny,Grab isee nodes) Containers Sample Comments a jl-2. 11-1 i-..20243 13 3o __sw • , x • • • • • • _T • Y— I _<--Total#of Containers Sample Kit Prepared By l Date/Time Relinquished By r Date, ne U/ Race' Date/Time I 0 Comments/Special ({( 1 Z O� s //` Speaal Reporting Requirements Relinquished By D 'me Reg& By Dale/Time J Relinquished By Date/Time Received By `♦/ Date/Time Its&Temps on Receipt ConWtionu[)oon Receipt .to t 'Jf// c Acceptable _Unacceptable Matrix GW-Groundwater SO-Soil DW-Dnnkng Water SE-Sediment SW-Surface Water WW-Wastewater A-Air 0-Other(detail In comments) Preservation:I-Ice H-HCI N-HNO3 S-H2SO4 NO-NaOH O-Other(detail in comments) • Note All samples submdted to ENCO Labs are in accordance with the terms and conditions listed on the reverse of this form,unless prior written agreements exist