Loading...
HomeMy WebLinkAboutWQCSD0403_BIMS Report_20201208Permit: WQCSD0403 SOC: County: Iredell Region: Mooresville Compliance Inspection Report Effective: 11/16/10 Expiration: Owner : Aqua North Carolina Inc Effective: Expiration: Facility: Mallard Head Collection System Contact Person: Michael A Melton Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Title: Engineering Manager Certification: Related Permits: NC0062481 Aqua North Carolina Inc - Mallard Head WWTP Phone: 704-489-9404 Ext.57238 Phone: Inspection Date: 12/02/2020 Entry Time 02:OOPM Exit Time: 03:OOPM Primary Inspector: Tony Parker Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions General Grease Control Spills/Response Plan Lines Manholes (See attachment summary) DocuSigned by: ' 12/8/2020 Page 1 of 5 Permit: WQCSD0403 Owner -Facility: Aqua North Carolina Inc Inspection Date: 12/02/2020 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Page 2 of 5 Permit: WQCSD0403 Owner -Facility: Aqua North Carolina Inc Inspection Date: 12/02/2020 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE # Is this system a satellite system? ❑ 0 ❑ ❑ # If Yes, what is system name or permit number? Is there a overall sewer system map? ❑ ❑ ❑ Does the map include: Pipe sizes ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) 0 ❑ ❑ ❑ Pipe location ❑ ❑ ❑ # Flow direction ❑ ❑ ❑ # Approximate pipe age ❑ ❑ ❑ # Pump station ID, location and capacity ❑ ❑ ❑ # Force main air release valve location & type ❑ ❑ ❑ # Location of satellite connections ❑ ❑ ❑ Are system maintenance records maintained? 0 ❑ ❑ ❑ Comment: This is a private investor owned deemed system with all gravity flow with no P/S's. Grease Control Yes No NA NE Is grease/sewer education program documented with req'd customer distribution? ❑ ❑ ❑ # Are other types of education tools used like websites, booths, special meetings, etc? ❑ ❑ ❑ If Yes, what are they? (This can reduce mailing to annual.) Mail outs 2/year and on web site. For public systems, is there a Grease Control Program via an ordinance/agreement? ❑ ❑ ❑ If Yes, does it require grease control devices at applicable locations? ❑ ❑ ❑ Is the Grease Control Program enforced via periodic inspections/records review? ❑ ❑ ❑ Is action taken against violators? ❑ ❑ ❑ Comment: Spills and Response Action Plan Yes No NA NE # Is system free of known points of bypass? ❑ ❑ ❑ # Have there been any sewer spills in the past 3 years? ❑ ❑ ❑ If Yes, were they reported to the Division if meeting the reportable criteria? ❑ ❑ ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ ❑ Are all spills or sewer related issues/complaints documented? ❑ ❑ ❑ # Are there repeated overflows/problems (2 or more in 12 months) at same location? ❑ ❑ ❑ # If Yes, is there a corrective action plan? ❑ ❑ ❑ Is a Spill Response Action Plan available? ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? ❑ ❑ ❑ Page 3 of 5 Permit: WQCSD0403 Owner -Facility: Aqua North Carolina Inc Inspection Date: 12/02/2020 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: # 24-hour contact numbers 0 ❑ ❑ ❑ # Response time ❑ ❑ ❑ # Equipment list and spare parts inventory ❑ ❑ ❑ # Access to cleaning equipment ❑ ❑ ❑ # Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ # Source of emergency funds ❑ ❑ ❑ # Site sanitation and cleanup materials ❑ ❑ ❑ # Post-overflow/spill assessment ❑ ❑ ❑ Comment: Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of Ways/Aerial Lines Inspected: No aerials or HPL's. Are right-of-ways and easements maintained for the full width for access? ❑ ❑ ❑ ❑ If No, give details on temporary access: Is maintenance documented? ❑ ❑ ❑ Were all areas/lines inspected free of issues? 0 ❑ ❑ ❑ Comment: Aqua contract cleaned 1,313' of line and inspected 7 M/H's for the review period. Manholes Yes No NA NE Please list the Manholes Inspected: Numerous M/H's inspected. Approximately 4 or more M/H's need to be reset. These were also noted by contractor records Are manholes accessible? ❑ ❑ ❑ # Are manhole covers/vents above grade? ❑ ❑ ❑ Are manholes free of visible signs of overflow? ❑ ❑ ❑ Are manholes free of sinkholes and depressions? ❑ ❑ ❑ Are manhole covers present? ❑ ❑ ❑ # Are manholes properly seated? ❑ ❑ ❑ # Are manholes in good condition? ❑ ❑ ❑ # Are inverts in good condition? ❑ ❑ ❑ Is flow unrestricted in manholes? ❑ ❑ ❑ Are manholes free of excessive amounts of grease? ❑ ❑ ❑ Are manholes free of excessive roots? ❑ ❑ ❑ Are manholes free of excessive sand? ❑ ❑ ❑ Are manhole vents screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? ❑ ❑ ❑ Page 4 of 5 Permit: WQCSD0403 Owner -Facility: Aqua North Carolina Inc Inspection Date: 12/02/2020 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Comment: See above comments. Page 5 of 5