HomeMy WebLinkAboutWQ0042079_Application (FTSE)_20201028State of North Carolina
DWR
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Dlv[sion of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: tA/tO P �J_ Ito be completed by DWR) 1 d — 4 f
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
I. Applicant's name: City of Mebane (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: David Cheek per 15A NCAC. 02T .01- 06(b)
Title: Ci_, Manager
4. Applicant's mailing address: 106 East Washington Street
City: Mebane State: NC Zip: 27302-
5. Applicant's contact information:
Phone number: 919 563-5901 Email Address: dcheek�a?,cityof mebane.com
11. PROJECT INFORMATION:
1. Project name: Bowman Place
2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project
If a modification, provide the existing permit number: WQ00 and issued date:
If new construction but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Orange
4. Approximate Coordinates (Decimal Degrees): Latitude: 36.068992 Longitude:-79.245105
5. Parcel ID (if applicable): 9824-73-6163 =
(or Parcel ID to closest downstream sewer)
o C
III. CONSULTANT INFORMATION: N
1. ProfessionaI Engineer: Charles P. Koch License Number: NC #022634 0 cc _ c
Firm: EarthCentric Engineering Inc. N 0
Mailing address: 204 West Clay Street W ~
a
City: Mebane State: NC Zip: 27302-
Phone number: 9(, 19) 563-9041 Email Address: Phil.KochQEarthCentric.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
I. Facility Name: City of Mebane WRRF Permit Number: NCO021474
Owner Name: Ci1y of Mebane
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ0041680 Downstream (Receiving) Sewer Size. 8 inch
System Wide Collection System Permit Number(s) (if applicable): WOCS00081
Owner Name(s): City of Mebane
s
Ix
FORM: FTA 04-16
Page 1 of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®NIA
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑No ®NIA
3. If the Applicant is a Home/PropeM Owners' Association erational Agreement FORM A been attached?
❑ Yes [:]No ®N/A
4. Origin of wastewater: (check all that apply):
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial % Commercial
% Industrial See I5A NCAC 02T .0103 20 )
bIs there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .01 14(f)? ® Yes ❑ No
If yes, provide a covy of flow reduction angroval letter
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114tf�1
Daily Design Flow
No. of Units
Flow
single-family home, 4-bedroom
320 gal/day
128
40,960 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gall
GPD
T01a!
40,960 GPD
t,/
a See 15A NCAC 02T .0114(h), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I SA NCAC 02T.0114] shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 40.960 GPD (per I $A NCAC 02T .0114) /
Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number:
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers),
I. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8"
2,042
Ductile Iron
8"
2,378
PVC
T�'aO
➢ Section II & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Puma Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
l . Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
6. Power reliability in accordance with 15A NCAC 02T .0305 I :
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(I)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)):
I. Does the project comply with all separations found in 15A NCAC 02T .0305(f} & W ®Yes ❑ No
15A NCAC 02T.0305(f) contains minimum separations that shall be nrovided for sewer systems-
Setback Parameter*
Se aration Required
Stone sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feet
"Any private or public water supply source, including any wells, WS-I waters of Class I or
Class 11 impounded reservoirs used as a source of drinking water
100 feet
"Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
**Any other stream, Iake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage s stems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
D 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305 cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpa�e
➢ If noncompliance with 02T.0305(ff) or W. see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N:-A
➢ Seethe Division's draft separation requirements for situations where separation cannot be meet
D No variance is required if the alternative design criteria specified is utilized in design and construction
D As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ®NSA
D This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No
individual permits or 401 Water Quality Certifications?
D Information can be obtained from the 401 & Buffer Prrmh1ing Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6}, directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stonnwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ® No ❑ NIA
z If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
I. Does the submitted system comply with ISA b1CAC 021, the Minimum Design Criteria for the Permitting of Pumg..S_tations_
and Force Mains (latest version), and the Gravity Sewer Minim um Desifzn Criteria (latest version) as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the request is required prior to submittal of the Fast Track Application and suoportine documents.
2. Professional Engineer's Certification:
�2S R k oG � attest that this application for
(Professional Engineer's name from Application Item I11.1.)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and do
3. Applicant's Certification per 15A NCAC 02T .0106(b):
I, Do q,d Ueek r attest that this application for
(Signature Authorit9l name & tit from Application Item 1.3.)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non -
discharge system to surface waters or the Iand will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature:
2020.10.20
OVA 1: i IA 11
FORM: FTA 04-16 Page 5 of 5
State of North Carolina
Department of Environmental Quality
DWR Division of Water Resources
Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: , City of Mebane
Project Name for which flow is being requested: Bowman Place
More than one FTSE may be required for a single project f the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: City of Mebane
b. WWTP Facility Permit #: NCO021474
AI! f to ws are in MGD
c. WWTP facility's permitted flow 2.500
d. Estimated obligated flow not yet tributary to the WWTP .686
e. WWTP facility's actual avg. flow 1.597
f. Total flow for this specific request 0.041
g. Total actual and obligated flows to the facility 2.283
h. Percent of permitted flow used 91 %
II. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B}
(C)
(D)=(B+C) (E)=(A-D)
Design
Obligated,
Pump
Average Daily
Approx.
Not Yet
Total Current
Station
Firm Flow**
Current Avg.
Tributary
Flow Plus
(Name or
Capacity, * (Finn / pi),
Daily Flow,
Daily Flow,
Obligated Available
Number)
MGD MGD
MGD
MGD
Flow Capacity***
SE Reg. 2.5 1.0 0.249 0.260 0.509 0.491
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pf) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): City of Mebane
Downstream Permit Number: WQ0039116
Page l of 6
FTSE 04-16
III. Certification Statement:
I David Cheek certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessment addendums for which I am the responsible party. Signature of this
form indicates acceptance of this wastewater flow.
056,64 2020.10.20 12:16:26-04'00'
Signing Official Signature
Date
Page 2 of 6
FTSF n4-16
Azign
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins
Govemor Director
March 15, 2011
Robert L. Wilson
City Manager
City of Mebane
106 East Washington Street
Mebane, NC 27302
Subject: Mebane WWTP (NC0021474)
Flow Reduction Request
Alamance County
Dear Mr. Wilson:
Dee Freeman
Secretary
On February 14, 2011, the Pretreatment, Emergency Response and Collection System (PERCS) Unit of
the Division of Water Quality received a flow reduction request for connections to the City of Mebane WWTP.
The letter requests an allowable flow rate of 80 gallons per day (gpd) per bedroom based on the evaluated data.
As daily WWTP data is not representative of the project area, the DMR data from the City of Mebane
WWTP (NC002I474) from January 2009 through December 2009 was evaluated to determine the peals sewage
month. The highest flow month was December 2009. Daily wastewater flows were recorded downstream of
the Holly Ridge Subdivision during December 2010. This data was reviewed by PERCS and Regional Office
staff.
Based on the data, the Division hereby grants a reduction in flow to 80 gpd/bedroom (minimum of 160
gpd for 1 and 2 bedroom residences) for sewer extension permits issued tributary to the City of Mebane
WWTP.
Regardless of the adjusted design daily wastewater flow rate, at no time shall the wastewater flows
exceed the effluent limits defined in the NPDESRermit for the treatment facility or exceed the capacity of the
sewers downstream of any new sewer extension or service connections .
If you have any questions or comments regarding this matter, please contact Sarah Morrison at (919)
807-6310, or email [Sarah.Morrison@ncdenr.gov] or Deborah Gore, Unit Supervisor at (919) 807-6383, or
email [Deborah.Gore@ncdenr.gov].
Sincerely,
; f Coleen H. Sullins
cc: Darrell L. Russell, P.E., Alley, Williams, Carmen & King, Inc. (via email: drussell awcILcom)
Steve Mauney, Winston-Salem Regional Office (via email)
NPDES Unit, Permit File NCO021474
PERCS Flow Reduction File
1617 Mail Service Center. Raleigh, North Carol'na 27699.1617
Location:512 N Salisbury St Raleigh. North Carolina 27604 One
Phone 919.8a7-6=%FAX: 919-807-64921PERCS vnitFAX 9'�-.?07-6489%G:stomerService:1-877.523.6748 NprthCarolina
Intemet hbJ/portal.ncdenr.orolxrebJwg! PERCS Unit h J! rtal.ncdenr. re atura!!J
An EqL � Opportunity 1 Affirmative Action Employer
Project: Bowman Place
ECE Project # 19-008
Information provided by: Shawn C. Sidener
204 West Clay Street
Mebane, NC 27302
Phone: (919) 563-9041
Fax (919) 304-3234
Page 1 of 1
Cover Letter, wastewater flow calculations and project narrative for NCDEQ, Division of water
quality Fast -Track Sewer System extension application.
Project Narrative:
The Bowman Place project consists of a new 128 lot subdivision which is part of a larger 177 lot
subdivision with associated public roadways, utilities, open space, drives, parking, etc. being built
on two parcels of land totaling 68.64 acres. The phases included for Bowman Village have been
permi tedtugUbr a separate cover. The homes will be a mix of three- and four -bedroom models.
The site is la4ated in the vicinity of 7117 Bowman Road, Mebane North Carolina with this
portiog-of the site being south of Bowman road. It can be identified with PIN# 9824-74-5328 &
-9924-73-6163. The development of this subdivision will require a public sewer extension to tie
into the City of Mebane sewer system. This portion of the gravity sewer extension will consist of
22 new manholes, 2,,042 If of 8" ductile iron pipe (DIP) and 2,378 If of 8" PVC pipe. The new
sewertmain will tie into a City of Mebane 8" ductile iron sewer main at a newly constructed
manholr, which is part of the Bowman Village sewer permit submittal.
Wastew F ws:
} -4 bedroom residential homes 80* gallons/day/bedroom with a 160* gallons/day min.
(Exact' mix unknown, calculated at highest possible volume)
* See attached Flow Reduction Approval for the City of Mebane
128 homes x 4 bedrooms x 80 gallons ~ 40,960 gallons/day
Total Wastewater Flow = 40,960 gallons / day
Items included with this acka e: one original and one co
- Cover letter
- Application fee of$480.00
- Fast -track Application
- Flow Tracking / Acceptance Form
- USGS Map
Street level Map
City of Mebane Flow Reduction Approval
X-16
a�
ti Na
�`ti�NO
�C,
�G4
N&