Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0042065_Application (FTSE)_20201027
DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: D (to be aomplocd by Db1 R) All items must be completed or the anmlication will be returned I. APPLICANT INFORMATION: I. Applicant's name: Town of Norlina (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State -County ® Municipal 3. Signature authority's name: Wayne Aycock. per 15A NCAC 02T .0106(b) Tide: Miyor 4. Applicant's mailing address: 139 Hyco Street City: Norlina State: NC Zip: 27563-__ 5. Applicant's contact information: Phone number: (252) 456-3325 Email Address: to%vnclerk(@townofnorlina.com Privately -Owned Public Utility ❑ Other 11. PROJECT INFORMATION: r 1. Project name: Waste Water Pump Station Improvement 2. Application: Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00_ and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Warren 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.458180 Longitude:-78.205668 5. Parcel ID (if applicable): 2938367819 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: David G. Malinauskas License Number: 029997 Firm: The Wooten Company Mailing address: 120 North -Boylan Avenue, City: Raleigh State: NC Zip: 27603-1423 Phone number: 919) 828-0531 Email Address: dmalinauskas thewootencom an .com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Warren County WWTP Permit Number: NC 0020834 Owner Name: Warren County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection $ystem Permit Number(s) of applicable): WQCS_ _1Q6� Owner Name(s): _ v w� FORM: FTA04-16 Page I of V1. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No (EM-A 2. If the Applicant is a Developer of lots to be sold, has a Develoyer's Operational At4reement (FOR i:.DEV) been attached? ❑ Yes ❑No ®N'A 3. If the Applicant is a llorne-11royero, Owners' Assuciation, has an Operational Agreement (FORM:.HOA) been attached? ❑ Yes [:]No ON -A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparationiservice ❑ Hotel and/or Motels ❑ School preschool day care ❑ Medical! dental : veterinary facilities ❑ Swimming Pool 'Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool,'Filter Backwash El Businesses offices factories El Nursing Home ® Other (Explain in Attachment) 5. Nature of wastewater. 100 °o Domestic."Commercial _ % Commercial 0 0o Industrial (See 15.A.NCAC 02T,Q103(20)) �Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14A? ❑ Yes ® No I r ves, provide a coov or now reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01140 Daily Design Flow ° b No. of Units Flow gall GPD gall GPD gall GPD gal/ GPD gal/ GPD gall GPD Total 0 GPD a See 15A NCAC 02T .0I 14(b), [d), (e)(1) and COL2J for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .01144(c), design flow rates for establishments not identified [in table 15A-NCAC 02T,01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GAD (per 15A NCAC 02T .0114) �- Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ® Other (Explain): Replacement of existing sewer infrastructure. No proposed expansion of system. FORM. FTA 04-16 Page 2 of 5 Vil. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Vill. l 2 3 4 5 Size (inches) Length (feet) Material 8 955 PVC > Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) D Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: Old Lagaon Approximate Coordinates (Decimal Degrees): Latitude; 36.458189 Longitude:-78.205852 Design flow of the pump station: 0.57 millions gallons per day (firm capacity) Operational point(s) of the pump(s): 400 gallons per minute at 161 feet total dynamic head (TDH) Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 8 5275 PVC 8 375 DIP 4 360 PVC 6. Power reliability in accordance with I SA NCAC 02T 0. 305(h_Xl: r- S ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station_ i If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of IX. SETBACKS & SEPARATIONS - (0213.0200 & 15A NCAC 02T .0305(f)): I _ Does the project comply with all separations found in 15A NCAC 02T .0305(f) & t :- 15A NCAC 02T.0305(f) contains minimum separations that shalt he provided Fnr sewer Cyupmv © Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, FIQW, or SB from normal high water (or tide elevation) and wetlands see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet An basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage s stems and interceptor drains 5 feet Any swimming pools 10 Feet Final earth grade (vertical) 36 inches 15A NCAC 02T.03. 05(g) contains alternatives where separations in 02J.03305(Jo cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications webRaee If noncompliance with 02T.0305(f) or (6, see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N:A ;w See the Division's draft separation requirements for situations where separation cannot be meet i No variance is required if the alternative design criteria specified is utilized in design and construction i As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 0213 .0200-2 ® Yes ❑ No ❑ N A This would include Trout Buffered Streams per I SA NCAC 2B.0202 4. Does the project require coverage.:authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ;,- Information can be obtained from the 401 & Buffer Permittine Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6}, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC .-02_T.0�402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ❑ No ❑ N;'A If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per I5A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NC.AC 02T, the Minimum Design Criteria for he.permjltin�,, of Pump Stations and Force Mains i latest versionl; and the Gravity Sewer Minimum Design Crileria I latest version as applicable? ® Yes ❑ No If No, complete and submit the Variance, -`Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: 1 '� o-- - J to . {Y1 is t : n o. v. s l.t c,r _,. _attest that this application for (Professional Engineer's name from Application Item 11I.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Appplica/nt's Certification per 15A NCAC 02T .0106(b): I, Wah tt-., A44m_ ature Authority's name & title from Application Item 1.3.) •oF 9� •, 029997 = GINEE• J • MWWN ,,%" . ........ �! 1, P.A a attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6.B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: - 2 o' z o FORM: FTA 04-16 Page 5 of 5 w +� 9 i Sri o ti 4P i * { fw +' ` + z r O # + top oaks rry Proposed GSjapprox 40 i * Pines '! King -.Drive Proposed FM(approx) Proposed FM(approx) ' Sh Norifin It A was _ Im Stroe!< a F •� � IN ry October 26, 2020 Reviewer THENCDEQ - Division of Water Resources Water Quality Permitting Section wooTEN Wastewater Branch — PERCS Unit COMPANY 512 N. Salisbury St. Archdale Building, 9"' Floor Raleigh, NC 27604 120 North Boylan Ave. Raleigh, NC 27603 919328 0531 fax 919.834 3589 CDept opEnvironn7ent;�l 11alit Y OCT 2 7 2020 Raleigh Regioll,11 Ofr ee Re: Sewer Fast Track Application Sanitary Sewer Force Main and Waste Water Pump Station Improvements Town of Norlina Norlina, North Carolina TWC No. 251 1-BW Dear Reviewer: On behalf of the Town of Norlina, we are submitting one (1) original and one (1) copy of the following documents related to the above referenced project for your review and approval: • Application Fee ($480.00) • Sewer Fast -Track Application (FTA 04-16) • Cover Letter Narrative (see paragraphs below) • USGS Topographic Map showing proposed utilities • Aerial map showing general project area This project will replace a sewer pump station (Old Lagoon), upgrade existing sewer pump stations, and install approximately 5,275 linear feet of 8" PVC and 375 LF of 8" DI force main, approximately 360 linear feet of 4" C900 PVC force main, and approximately 950 feet of 8" PVC and DI gravity sewer. In addition, by extending the new 8" gravity sewer and 4" force main, the Town will be able to decommission an existing pump station. The project area is currently served with sewer. This project is a replacement of infrastructure that is beyond design life. The collection system is not expanding due to this project. New gravity sewer will be installed, but only to decommission the existing pump station - it will not serve any existing or proposed connections. As no expansion of the collection system is proposed, this is a zero -flow project. As such, no Flow Tracking form is included with this submission. Sewer force main from Old Lagoon Pump Station will be installed parallel to existing force main and connected to gravity sewer. Force main and gravity THE WOOTEN COMPANY 120 North Boylan Ave. Raleigh, NC 27603 919 82B 0531 fax 919 834 3589 sewer will be installed adjacent to US 1 and its intersection with Elementary Avenue. Please see the table below for improvements proposed to the Town's pump stations. The Town of Norlina will own and maintain the proposed pump stations, force main, and gravity sewer after construction. All new sewer improvements have been designed in accordance with the 15A NCAC 02T requirements. Puma Station Imorovements Pump Station Improvement Old La oon Elm St. Pines Hillto Oaks Kin Dr. Shaw Dr Decommission Station X X Constrtuct New Station X Install SCADA System X X Install Spare Pump X X X X X Install Backup Generator X X X X Install Bypass Connection X X X X Install Trash Basket with Manhole X X Replace Security Fencing X Replace Grass with 6" ABC X X X X X We think the information provided is a complete submission and adequate for your review. If we can provide additional information or answer questions you may have, please feel free to contact us at (919) 828-0531 or email me directly at dmalinauskasthewootencompany.corn. Sincerely, THE WOOTEN COMPANY )-k Ja David G. Malinauskas, PE Water Resources Practice Manager Enclosures: as stated. cc: Blaine Reese, Town of Norlina (letter only) TWC Reading rile (letter only)