HomeMy WebLinkAboutWV0700153_Monitoring (Report)_20201006Environmental Chemists, Inc.
envirochem
ANALYTICAL 8; CONSULTING CHEMISTS
6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.392.4424 Fax
710 Bowsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/Fax
255-A Wilmington Highway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax
info@environmentalchemists.com
Town Of Nags Head Date of Report: Oct 05, 2020
PO Box 99 Manteo Report #: 20M-1709
Nags Head NC 27959 Report #: 2020-16282
Attention: David Ryan Customer ID: 09020021
Project ID: NH Acres
Lab ID Sample ID: Collect Date/Time Matrix Sampled by
20-41627 Site: Pond Header Pipe 9/23/2020 8:05 AM Water Client
Test
Method
Results
Date Analyzed
Ammonia Nitrogen
EPA 3501
2.5 mg/L
09/30/2020
Chloride
SM 4500 Cl E
98 mg/L
09/30/2020
Total Phosphorus
SM 4500 P F
0.81 mg/L
10/01 /2020
Total Nitrogen (Calc)
Total Kjeldahl Nitrogen (TKN)
EPA351.2
2.9 mg/L
10/01/2020
Nitrate+Nitrite-Nitrogen
EPA353.2
0.04 mg/L
09/25/2020
Total Nitrogen
Total Nitrogen
2.9 mg/L
10/05/2020
Lab ID Sample ID: M-3022 Collect Date/Time Matrix Sampled by
20-41628 Site: Pond Header Pipe 9/23/2020 8:05 AM Water Client
Test Method Results Date Analyzed
Fecal Coliform SM 9222D MF <1 Colonies/100ml- 09/23/2020
Comment:
Reviewed by: J�
Report #::2020-16282 Page 1 of 1
Environmental Chemist, Inc., Wilmington, NC Lab #94 6602 Windmill Way
Wilmington, NC 28405
910.392.0223
Sample Receipt Checklist
Client: ( -Not �S �e; Date: 2qi w Report Number: ���6f F—
Receipt of sample:
Deliverekp UPS ❑ FedEx ❑ Other ❑
❑ YES
❑ NO
N/A 1. Were custody seals present on the cooler?
❑ YES
JE1 NO
IV N/A 12. If custody seals were present, were they intact/unbroken?
Original temperature upon receipt
°C Cor cted temperature upon receipt_
How temperature taken:
❑ Temperature Blank Against Bottles
IR Gun ID: Thomas Traceable S/N 192511657 IR Gun Correction Factor °C: 0.0
❑ YES 10
NO
1 3. If temperature of cooler exceeded 6°C, was Project Mgr./QA notified?
kO YES 10
NO
1 4. Were proper custody procedures (relinquished/received) followed?
�( YES
❑ NO
1 5. Were sample ID's listed on the COC?
YES ❑ NO
1 6. Were samples ID's listed on sample containers?
YES 10 NO
1 7. Were collection date and time listed on the COC?
YES 10 NO
1 8. Were tests to be performed listed on the COC?
YES 10 NO
1 9. Did samples arrive in proper containers for each test?
YES 10 NO
110. Did samples arrive in good condition for each test?
YES ❑ NO
Ill. Was adequate sample volume availableT
YES ❑ NO 112.
Were samples received within proper holding time for requested tests?
YES
I ❑
NO
1 13. Were acid preserved samples received at a pH of <2?
❑ YES
I ❑
NO
114. Were cyanide samples received at a pH >12?
YES
❑
NO
115. Were sulfide samples received at a pH >9?
YES
❑
NO
116. Were NH3/TKN/Phenol received at a chlorine residual of <0.5 m/L? **
❑ YES
❑
NO
17. Were Sulfide/Cyanide received at a chlorine residual of <0.5 m/L?
❑ YES
ID
NO
118. Were orthophosphate samples filtered in the field within 15 minutes?
* TOC/Volatiles are pH checked at time of analysis and recorded on the benchsheet.
** Bacteria samples are checked for Chlorine at time of analysis and recorded on the benchsheet.
LSby
ple Preservation: (Must be completed for any sample(s) incorrectly preserved or with headspace)
ples) were received incorrectly preserved and were adjusted accordingly
dding (circle one): HZ50 HNO3 HCI NaOH
e of preservation: If more than one preservative is needed, notate in comments below
Note: Notify customer service immediately for incorrectly preserved samples. Obtain a new sample or
notify the state lab if directed to analyzed by the customer. Who was notified, date and time:
Volatiles Sample(s) were received with headspace
COMMENTS:
DOC. QA.002
m
b'l
710 Il3ovvagrtowr� Road
[4V�indriiill%`Way
in
ENVTROl�ME, NTAL CHE ISTS INS'
':"
Mani � :•27 �
� 9 d'
6 on NC 28405
?lione:`(910) 392-0223
Outer Banks
Division
., ;`:
�
Phone: (2�2) 473.5102
;F'asc (910) 392-4424
CDLNC D'UVQ Certificate #9�1
'_
Samle Collection an d Chain of Ci><stocl
�-�"�• �
i Certificate PUB
NCDL�NC DWQ
Mq?-Client, l tdl541a
-sn
Collected By:
�H
2i
Re Fo�'t No;
j Sam le T }e: Y = Ynfluent
LT = Effluent W = 'ell ST=Stream SO =Soil SL= Slud a
Other:'.°
.8ample Identification
Collection
a s
p ch o o lbo
rmfti RVATION
a 0 ANALYSIS RXQTBSM
14PA
u
W
,i s--
DATE, TIME TLMr v
U x
—
y
i�l
G
G
f�.,�
l J
1r•,
!
�
.
-
-
C
G
r
G
C
r
G
G
C
r
--
G
G
C
P
(r
-
G
'
c
r
-
-
G
G
i✓Y1�, ,, -�h 1.
c
r
far
Ammonia,
NOTICE — D + CHLORYNATIO N : Samples
TIi1V,
Cyanide, Pl�enol�nncl
bacteria
must be declilorinatecl
(0.2 ppm
or less) in the field at
the time of collection. See reverse side
far fast+-uciions.
Trnnsfer Reli riquisl)ed By. Date/Time '
Received By;
Date/Time
ICI Tel
A 3
cc
`k'e
�3
Wrature w fen eceived:
'Delivered By:
Accepted; cc e+ .
Resample Re nested:
:,
Received Dy:
Date.
li Time
�`.Cl�+: is
F: