HomeMy WebLinkAboutWV0700114_Data Monitoring Reports_20201207[envirrochem) ANALYTICAL & CONSULTING CHEMISTS Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.392.4424 Fax 710 Bowsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilmington Highway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax info@environmentalchemists.com Town Of Nags Head Date of Report: Dec 04, 2020 PO Box 99 Manteo Report #: 20M-2070 Nags Head NC 27959 Report #: 2020-19642 Attention: David Ryan Customer ID: 09020021 Project ID: Pond Ave. Dewatering Lab ID Sample ID: Collect Date/Time Matrix Sampled by 20-49993 Site: Pond Header Pipe 11/17/2020 10:35 AM Water Client Test Method Results Date Analyzed Ammonia Nitrogen EPA350.1 4.0 mg/L 11/25/2020 Chloride SM 4500 Cl E 56 mg/L 11 /23/2020 Total Phosphorus SM 4500 P F 0.56 mg/L 12/01 /2020 Total Nitrogen (Calc) Total Kjeldahl Nitrogen (TKN) EPA351.2 4.1 mg/L 11/30/2020 Nitrate+Nitrite-Nitrogen EPA353.2 < 0.02 mg/L 11/24/2020 Total Nitrogen Total Nitrogen 4.1 mg/L 12/01/2020 Lab ID Sample ID: M-3614 Collect Date/Time Matrix Sampled by 20-49994 Site: Pond Header Pipe 11/17/2020 10:35 AM Water Client Test Method Results Date Analyzed Fecal Coliform IdexxColdert-18 <1 MPN/100ml 11/17/2020 Comment: Reviewed by: Report #::2020-19642 Page 1 of 1 Environmental Chemist, Inc., Wilmington, NC Lab #94 Sample Receipt Checklist 6602 Windmill Vv Wilmington, NC 284 910.392.02 Client I ' 1 1 er--4J Date: I � '1 � Z(� Report Number: 20 Qj (r,Ll Receipt of sample: ECHEM Pickup ❑ Client Delivery ❑ 1 UPS FeclEx ❑ Other ❑ ❑ YES ❑ NO N/A 11. Were custody seals present on the cooler? ❑ YES ❑ NO N/A 2. If custody seals were present, were they intact/unbroken? Original temperature upon receipt °C Corrected temperature upon receipt 1How temperature taken: ❑ Temperature Blank IX Against Bottles IR Gun ID: Thomas Traceable S/N 192511657 IR Gun Correction Factor °C: 0.0 ❑ YES 10 NO 13. If temperature of cooler exceeded 6°C, was Project Mgr./QA notified? YES LEJ NO 14. Were proper custody procedures (relinquished/received) followed? YES ❑ NO 5. Were sample ID's listed on the COC? YES ❑ NO 6. Were samples ID's listed on sample containers? YES ❑ NO 7. Were collection date and time listed on the COC? O R. Were tests to be performed listed on the COC? O 9. Did samples arrive in proper containers for each test? O 10. Did samples arrive in good condition for each test? O 11. Was adequate sample volume available?' tE3Y MONO O 12. Were samples received within proper holding time for requested tests? O 13. Were acid preserved samples received at a pH of <2? O 14. Were cyanide samples received at a pH >12? O 15, Were sulfide samples received at a pH >9? O 16. Were NH3/TKN/Phenol received at a chlorine residual of <0.5 m/L? ** ❑ YES ❑ O NO 17. Were Sulfide/Cyanide received at a chlorine residual of <0.5 m/L? 18. Were orthophosphate samples filtered in the field within 15 minutes? * TOC/Volatiles are pH checked at time of analysis and recorded on the benchsheet. ** Bacteria samples are checked for Chlorine at time of analysis and recorded on the benchsheet. Sample Preservation: (Must be completed for any sample(s) incorrectly preserved or with headspace) Samples) were received incorrectly preserved and were adjusted accordingly by adding (circle one): H2504 HNO3 HCI NaOH Time of preservation: If more than one preservative is needed, notate in comments below Note: Notify customer service immediately for incorrectly preserved samples. Obtain a new sample or notify the state lab if directed to analyzed by the customer. Who was notified, date and time: Volatiles Sample(s) were received with headspace COMMENTS: DOC. QA.002 Rev 1 4 CD n CD I 1 0 1� F; r. M cv W SD mg cl CD o LAB ID CD C) 12- NOI�SRR En tIf 77 rL co II ur CD I Sample CJ N Type Composite cn or c CD CP Grab 11 ' 0 z corf� Container (Par G) Chlorine lj CD ><, NONE EICL ar CD =L BNQ3 NaOH 0 TMO OTf M rn cD I 1 cm CD CD CD It fo t7,