Loading...
HomeMy WebLinkAboutWQ0042080_Application (FTSE)_20201015I State or North Carolbs Department of Environmental Quality Dhision orwater Resources 15A NCAC 02T .0300 - FAST TRACK SERT:R SVSTV%I EATENNSION APPI ICATION W ewool., Waco of i•TA 04-16 d SUPPORTING DOCV.%IFNTATION Application Number `160 q 090 0 too be axszpLew bs Dwlt1 All Itrmf muse be comaleted or the_a-ogilstiilon %Ul be retained 10 /5 L APPLICANT INFORAtATIO:N I. Applicant's name_ Tow7._orClatitun (cumpan). municipalit), IIOA, utility. etc,) 2. Applicant type. ❑ lndn.dual ❑ Corporation ❑ General Partnership ❑ Prii ately-Ouiied Public 01111y ❑ Federal ❑ StatriCounty ® Municipal ❑ Other 3 Signature authonty's name RichCannola. PF per ' Title. QcmdN Jowtt_Manage� 4 Applicant's mailing w1dress PO Box 87V City- won State: NC Zip. 17 2 -_ 5. Applicant's contact infornwtion Phonc number (2W U -5W Ec=l Addnms. zya=la gAo%norclavtotinc.orx U. PROJECT INFORMATION; 1 Project name Lj9k!Qm* Outfall Seiner Line RmWc=nt 2_ Application/Project swats_ ® Proposed (New permit) ❑ Exming Permit/Project If modification. provide the cawing permit number %%'000 _.. and issued date- ., If new construction but part of a master plan, pro%ide the existing permit number- WQ00_.. y � 3 County u here ptojm is locate!. Johnston 71 71 4. Approximate Coordinates (Decimal Degrees)- Latitude },1,!4 Longitude, -7&4 cam+ S. Parcel ID (irapplicable)- v (or Parcel ID to closest downstream scwcr) 1-- 9� Ill. CONSULTA.N'T INFORMATION: I. Proressional Engineer License Number. QQZ2�2 ' Firm. ijg_ Wnotcn Comtuiny A Mailing address: 120 North Boylan Avenue INC Zip: �Q City: Ralf State; Z7603-1323 Phone number (21D 928-0531 Email Address- irmtzsch cr thewaotencomnanv.com IV. WASI'EWATERTREATNIENT FACILITY (WW]rF) INFORMATION: 1. Facility Name: Liyic Cork Water Rcrlamntion Faciltty Permit Number; NC00ZN53 Owner Name- Town orClam-n V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Numbet(s)- WQ_ Downstream (Receiving) Sewer Size. _ inch SMm Wide Collection S"Igm Pit h I . WQC5- Owner Name(s). FORM. FTA 04-16 page I ors 1• GENERAL REQUIREMENTS 1. if the Applicant is a Privately -Owned Public Utility, has a Ccrtiric:ate of Public Convcmence and Necessity been attached'? ❑ Yes [:]No ON A 2. If the Applicant is a Developer of lots to be sold, has a Dc%clot►cr's Oprrauonal Aercement I FORM: ntv been attached? ❑ Ycs ❑No ®N.'A 3. if the Applicant is a HomqTrol2crt Qw-ners' ti iati n hac a Operational A ent FO M: O been attached? ❑ Yes [:]No [D A 4. Origin of wastewater (check all that apply) ❑ Residential Owned ❑ Retail Otores, centers, malls) ❑ Car (Nash ❑ Residential U-ased ❑ Retail with food prepamtionlscry ice ❑ Hotel and;or Motels ❑ School ) preschool I day care ❑ Medical -dental veterinary facilities ❑ Swimming Pool ,`Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter 13ackw•ash ❑ Businesses I offices i factories ❑ Nursing llome ❑ Other (Explain in Attachment) 5, Nature of wastewater; _% DomestiCC'ommer ial % CommercW 5a Industrial (See 15A NCAC 02T .0 103(20)) L--b Is there a Pretreatment Program in effect? ❑ Yes [:)No 6- Hasa flow reduction been appruved under 15A NCAQ 02 A I ? ❑ Yes ®No i IfySI.provides rotivof now reduction aPProval letter 7. Summanze wastewater generated by project- Establisbment Type (see 02T.0114113) Dally Design Flow a6 No. of units Flow No new flow 0 gallday N A 0 GPD gal.' GPD gal/ GPD gal., GPD Sal;. GAD gat) GPD Total 0 GPD a See 15A NCAC 02TI4(bi. t4), feWD and (0142 for caveats to wastewater design flow rates (i.e-, minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas, and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in S�4ZA-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, w•xicr using fixtures, occupancy or operation patterns, and other measured data. g. Wastewater generated by project; 2 GPD (per 15A NCACO2T . 4 ;► Do not include future flows ar previously permitted allocations df permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain), FORM FTA 04-16 Page 2 of 5 II- GRAVITY SEWER DESIGN CRITERIA (1r Applicable) - 02T ,p305 do ,%1D ('rtiv ' 1. Sumntahze gravity sewer to be permttted. Sirs (inches) Length (reet) ~Material 30" 135' PVC 24' 925, PVC 24" 650' DI 12" 140' PVC I 175'+ 95' PVC/ DI 8" 205, PVC Section li & Ill of the h1DC for Pcrmitting ofGm%uy Sewers contains information related to design criteria L Section III contains information related to minimum slopes for grar ity sewcr(s) 3- Oversh ing lines to meet minimum slope requirement is not adluwcd and a violation or the MDC %'IIL PUMP STATION DESIGN CRITERIA (if Applicable) — OZT.9305 do AN1DC(PUMP atio or hI COMPUTE FOR EACH PUMP STATION INCLUDED IN IS PRD E Pump station number or name: IAA 2. Approximate Coordinates (Decimal Degrees). Latitude: Longitude_ - 3 Design flow of the pump station- millions gallons per day (firm capacity) d. Operational point(s) or the pump(s) Minions per minute at feet total dynamic head (TDII) S. Summxnze the force main to be permitted (for this Pump Station)' Size (inches) Length (feet) Slaterint 6- Power reliability in accordance with 15A N AC 02T ,03p5(U ll 1: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T.0305(.bXI X13)j i Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15.000 gallons per day -- Portable power source unth manual activanon, quick -connection r ccptacic and telemetry -15A NCAC 02T .0305(hx 1 xC) or ❑ Portable pumping unit with plugged emergency pump connecuon and telemetry - 15A NCAC 02T .0305(hX I XQ. r It Beall be demonstrated to the Division thal the portable source is owricd or contracted by the applicamt (draft agreement) and is compatible with the station r If the portable power source or purrtp is dedicated to multiple pump stations, an c►�iluation of all the pump statiatu' storage capacities and the rotation schedule of the portable power enure or Pump. including travel tirnef ttrn ,shall be provided in the case of a multiple station power outage - I ORhi FTA 04-16 PW 3 orS IX. SET13ACKSdc SEPARATIptiS-(02B.0200 & 15A NCAC 02T.0305(f)): Does the pan}act comply with all separations found in NCAC 02T -0 I5A NCAC_02T.03051 f) contains min imeim cnnnritinnc that chniI ire- nnn irt.vt far arum evetemc- ® Yes ❑ No Setback Parameter, S lion Required Storm sewers and other utilities not listed below 1%'ertical I 24 inchcs Wafer mains restiptl-water over sewer including in bunched tenches 18 inches Water mains i horizontal) 10 feet Reclaimed water lines vertical -reclaimed o+cr sewer► 18 inches Reclaimed water lines horirantal - reclaimed o%cr sewer) 2 feet "Any private or public water supply source, including any wells. DVS-1 waters of Class I or Gass 11 initiounded reservoirs used as a source ordrinking water 100 feet "Waters classified WS (except WS-1 or %VSA'). B. SA, ORN', l_IQ%'. or Sl3 from normal high water or tide elevation) and wetlands (sce ucm IX 2) 50 fect "Any other stream, lake, impoundment, or ground water luw Bring and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 fact Top sloe of embankment or cuts of 2 feet or mart vertical height 10 feet Drainage s stems and interceptor drains 5 feet Any swimming is 10 feet Final earth Lzrade 0crtical) 36 inches t5A NCAC 02T.03051g) contains altemativcs where separations m 02T.0305(f1 cannot be achieved. ;*Strewn classifications can be identified using the Division's NC Surface Water CWliflotions webnaae If noncompliance with 02T.0205(f) or (a). sec Section X of this application 2. Does the project comply with separation requirements for wetlands'? (50 feet of separation) ❑ Yes ® No ❑ N'A See the Division's draft separation requirements for situations where separation cannot be meet i No variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 0213,0200? ❑ Yes ® No ❑ N A �- This would include Trout Buffered Streams per 15A_NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes [:]No individual permits or 401 Water Quality Certifications? Information can be obtained from the 401 & Buffer Permitting Branch 5 Does project comply with 15A NCAC 02T.01051ckltl (additional permits/certifications)) ® Yes ❑ No Per 15A NCAC 02T.010&X6), directly related cmironmcntal permits or certification applications are being prepared, ha%e been applied for, or have been obtained Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.)- 6 Does this project include any sewer collection lines that are deemed "high -priority'''" Per ,I 5A NCAC 07T.0402„ -high-priority sewer" mesa+ "any aerial sewer. sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erasion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N. A 7 If yes, include an attachment with details for each line, including type (aerial lint, size, material, and location). Nigh priority lines shall be Inspected by the permitter or its representative at least once every SIX -months and Inspections documented per ISA NCAC 02T.0403(a)(S) or the pemitee's individual System -Wide Collection permit. I FOMI- FTA 04-16 Page 4 of 5 V CERTIFICATIONS: 1• Dots the submitted s}stem comply with ]5A NCAC_O,T, the� i sinCriteri a Lon the Permrttintt f PgMgi and the Grsvity_Sarer Itrnrmum Desi f0„Criteria stest version) as applicable? ® Yes No 1f No, complete and submit the Vanance_'Alterrative Design Request application (VADC 10-1.1) and supporting documents for review. mvnl f he eat i r sired Prior to submittal of the Fast Track Aripfication ands rt'n 2• Professional Engineer's Ccrtifcation: V \ ^C-1 attest that this application for Engineer's name from Applica n Item Itl.l_) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the ,Minimum Design Criteria for the Fast -Track Permitting of Pump Stanons and Force Mains (latest %ersion). Although other professionals may have developed certain Portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215 6A and 143-215.69, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor; which may include a fine not to eweed S 10.000. as well as civil penalties up to $25.000 per violation. North Carolina professional Engineer's seal signature,-- and date:„E.q,''l E L 7952 3 Applicant's Certification per ISA NCAC 02T .0106(b); l' A attest that this application for (5igna Authority"s name ti from Application IMm 1.3.) has bees) reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condmon of this permit be violated, I also understand that if all required pars of this application package are not completed and that if all required supporting information and attachments arc not included, this application package will be returned to me as incomplete !MOTE — In accordance with General Statutes 143-215,6A and 14 .'► .6i3 any person who knowingly makes any false statement. representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,o00 per violation. Signaaue Date; FORM_ FTA 04-16 Page 5 of 5 Ty THE WOOTEN COMPANY 12D Mom Sop Avenue Rafoo. NC 27EC3-1423 519 E28 C53 1 Fax 915 E3 35E9 U&N Iletwen=PXly CM t ctolkr I �. 2020 RECEIVED OCT 13 2020 Res ic" cr NCDI-Q - Di%iiion of%%'seer Rc*ulturceti NCDEQIDWR NPDES Archdale Building 512 N. Salisburs St. Raleigh. NC 27604 Subject_ Fast l neck Sesser S%steln l.ttension ApplicatiOWept c,1 T:nc ir�,Fintentt1l Quality Little Crech Outfall Sctscr Line Replacement Clacton, North Carolina OCT ? ! "r1�71 -i%%'C No.- 2756-131' Dcar Re% ie%%er: P..ticlSl� ��l''t1111c11 t t1 I L► On behalf ofthe l'o►s n of Cla%ton. A%e arc enclosing one (1) original and one (1) copy of the follo"ing documents for %our rc%icss and approsal regarding the above referenced project in Clayton, NC: • Application Fee ($480.00) • past Track Sc%%er Sy stem I-\tcnsion Application f 17TA 04-16) • USGS Topographic Map ■ Street Lctel Site flap This project includes the replacement and upsizc of approximately 1.450 linear feet of an existing municipal gras it% sanitary so%er outfall that discharges In the influent structure of the Little Creek Water Reclamation faeilit%. The project also includes the replacement of scscml tributary branches, mailing approximately 860 linear feet, that feed into the main outfall. 1-he upstream portion of the replacement has been realigned to mace the secser outside of an cxisting po%%er casement to the greatest extent possible. The main outfall will hp: upbized front 18- and 24- to 24" and 30". respective}% The; project does not include neNs sen ices and N%iII not generate or add nets floss to the collection system. All proposed %cork is to be constructed either across open land in new or existing permanent utility casement or across NCDOT-maintained roadways, specifically Snuth I ombard Street (NC Highssa) 42). -I'his project will he built per Totv,t of Clayton and The %Vooten Compan% construction standards. If %ou have questions or require additional information, please do not hesitate to contact me at (919) 828-0531 or kpierce &ihessootencomRanc .com or John Poetzsch at ' oetvsch rt)tltess, otemcon pally.com- Sincerely, THE WOOTEN COMPANY �';t' r,.. Kristen T. Pierce, P.G. cc: Richard D. Cappola PE, Deputy Town Manager, Town of Clayton (email wlcopy) Joshua Baird PE, Town Engineer, Town of Clayton (email wlcopy) TWC file 15 �v. q ILILSri ;rl 0 s�`�+r LAYTU *- l ' OAAu'RYF � �, � ► ti{ r 4til " k GuR,SOr AK T NrAVC. SLR 1 I� 47 s parrs PROJECT SITE �! + iif777 s k k � k r � rJL!'�lllSpl �i.r w 11 AV TOWN OF CLAYfON Date corms w Mom NOUH CAMMA OCTOBER 2020 LITTLE CREEK OUTFALL SEWER LINE REPLACEMENT Scale. THE WOOTEN COMPANY 1- _ 2,OW USGS TOPOGRAPHIC SITE MAP Project No. l 27s6-OP