Loading...
HomeMy WebLinkAboutSW6201101_Add Info Request_20201207ROY COOPER Governor MICHAEL S. REGAN Secretary BRIAN WRENN Acting Director Dan Saltsman, PE Stantec Consulting Services 801 Jones Franklin Road #300 Raleigh, NC 27606 NORTH CAROLINA Environmental Quality December 7, 2020 Subject: Request for Additional Information Stormwater Permit No. SW6201101 Military Working Dog Facility PN 752426 Cumberland County Dear Mr. Saltsman: The Division of Energy, Mineral and Land Resources (DEMLR), received a Stormwater Management Permit Application for the subject project on November 19, 2020. A review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: Please provide a plan that clearly labels all BUA within the project area, including the BUA that drains to the infiltration system, existing BUA, and offsite BUA. Based on the drainage area plan (SWM 102), the BUA draining to the SCM appears to be much lower than reported in the application, calculations, and Supplement EZ. The existing BUA within the drainage area also appears to be larger than reported on the application form (3,265 sf). 2. According to the Supplement EZ, the infiltration basin does not treat the net increase in BUA as required by 15A NCAC 02H .1003(3)(d). The form says that the new BUA on the entire site is 61,544 sf as opposed to 44,391 sf treated by the infiltration basin. 3. The design volume reported in Field 2 of the infiltration basin Supplement EZ sheet is less than the calculated minimum design volume (5,180 cf vs. 7,796 cf). 4. Please provide a detail of the infiltration basin that meets the requirements of 15A NCAC 02H .1042(2)(h). 5. Please add a note that states that the infiltration will be cleaned out after construction and converted to its approved design state [15A NCAC 02H .1050(7)]. Please also complete Field 10 of the infiltration basin Supplement EZ sheet. D EQ�� North Carolina Department of Environmental Quality Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center Raleigh, North Carolina 27699-1612 NoarH c �aouNa � Dopanmam f Environmental Quality /� 919.707.9200 6. Some of the runoff from the BUA is collected in catch basins and discharged directly into the infiltration basin without pretreatment. Pretreatment is required for all runoff discharged into an infiltration system [15A NCAC 02H .1051(4)]. 7. Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, and 1 hardcopy of other documents. Pdfs must be uploaded using the form at: hgps:Hedocs.deg.nc.gov/Forms/SW_Project Submittal Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to January 6, 2021, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. Please reference the State assigned project number SW6201101 on all correspondence. If you need additional time to submit the information, please submit your request for a time extension to the Division at the contact below. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. If you have any questions concerning this matter please feel free to contact me at Corey.Anen(cncdenr.gov or (919) 707-3649. Please note that due to the ongoing Covid-19 pandemic, I will be teleworking and will be most easily reached by email. Sincerely, Corey Anen Environmental Engineer Stormwater Program cc: Fayetteville Regional Office