December 01, 2020
SUBJECT: Compliance Inspection Report
The Grove WWTP
Non -discharge Permit No. WQ0024756
Carteret County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the The Grove WWTP on
11/18/2020. This inspection was conducted to verify that the facility is operating in compliance with the
conditions and limitations specified in Non -discharge Permit No. WQ0024756. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report". There were no significant issues or findings noted during the
inspection and therefore, a response to this inspection report is not required.
If you should have any questions, please do not hesitate to contact Helen Perez with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
helen.perez@ncdenr.gov.
Sincerely,
DocuSigned by:
I-T,O,-,,
OA, for
1 E73B6F3456...
Morelia Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS
Cc: Don O'Mara — electronic copy
Upload to Laser fiche
-x North CafoLnaDepartment offnvironmeata3Qua;ity I DiuisionofWater Resoarces
r, Wilmington RegiairaIOffice I =CArd'ina1DFivefxtensiao I WiNmington, North Caro:ina23405
�'T °y 1310-796-7215
Compliance Inspection Report
Permit: WQ0024756 Effective: 10/28/19 Expiration: 06/30/25 Owner : Fmb at the Grove LLC
SOC: Effective: Expiration: Facility: The Grove WWTP
County: Carteret 104 W Bogue Blvd
Region: Wilmington
Atlantic Beach NC 28512
Contact Person: Fred M Bunn Title: Manager Phone: 252-399-1617
Directions to Facility:
System Classifications: SI, WW2,
Primary ORC: Stanley Earl Buck Certification: 993396
Secondary ORC(s):
On -Site Representative(s):
On -site representative Donald P Omara
Related Permits:
WQ0032160 Fmb at the Grove LLC - The Grove Sewer System
Phone: 252-503-5307
252-247-9167
Inspection Date: 11/18/2020 Entry Time 10:OOAM Exit Time: 11:OOAM
Primary Inspector: Helen I Perez Phone: 910-796-7387
Secondary Inspector(s):
Reason for Inspection: Routine
Inspection Type: Compliance Evaluation
Permit Inspection Type: High Rate Infiltration
Facility Status: Compliant ❑ Not Compliant
Question Areas:
Treatment Flow Measurement -Effluent
Treatment Flow Measurement -Influent
Miscellaneous Questions
Treatment Flow Measurement -Water
Treatment
Treatment Barscreen
Use Records
Treatment Filters
Record Keeping
Treatment Activated Sludge
Treatment Clarifiers
Treatment Disinfection
End Use -Infiltration
Treatment Flow Measurement
Treatment Return pumps
Standby Power
(See attachment summary)
Page 1 of 7
Permit: WQ0024756 Owner - Facility: Fmb at the Grove LLC
Inspection Date: 11/18/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
A routine compliance inspection of The Grove WWTF was conducted on November 18, 2020. The purpose of the
evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit
WQ0024756. Operators, Don and Karrie O'Mara, were present during the inspection.
This extended aeration plant is permitted for 120,000 gpd but currently only has a flow average of 10,000-12,000 gpd in the
summer season and 5,000-9,000 gpd in the winter. Only one train is in operation due to the low flows. The plant is
surrounded by a public parking lot but is secured by a locked fence and signs are posted restricting public access. The
high -rate infiltration raised drip field is located across West Bogue Blvd. Earlier this year, as required by the schedule in the
new permit issued 10-28-19, the vegetation in the field was removed, landscape cloth installed and the drip lines raised. Pea
gravel has been added to cover the field.
During the last monitoring well sampling event, MW #1 was found to be damaged. A new well needs to be constructed
following 15A NCAC 02C .0108 rules as soon as possible to continue permit monitoring requirements.
A review of NDMR/NDAR reports since 2018 shows two daily fecal exceedances in May and July 2018. GW59 reports show
MW #2 had an ammonia exceedance in February 2018, and MW #3 had an exceedance in TDS in October 2018.
The facility is compliant with non -discharge permit WQ0024756. Please review the comment sections of the inspection
report for more details.
Page 2 of 7
Permit: WQ0024756 Owner - Facility: Fmb at the Grove LLC
Inspection Date: 11/18/2020 Inspection Type: Compliance Evaluation
Reason for Visit: Routine
Type
Yes No NA NE
Activated Sludge Drip, LR
❑
Reuse (Quality)
❑
Activated Sludge Spray, HR
❑
Activated Sludge Spray, LR
❑
Single Family Drip
❑
Single Family Spray, LR
❑
Recycle/Reuse
❑
Lagoon Spray, LR
❑
Infiltration System
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑
Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑
Comment: Due to low flows, only one train is in operation.
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually?
❑
❑ ❑
Is flowmeter operating properly?
❑
❑ ❑
Does flowmeter monitor continuously?
❑
❑ ❑
Does flowmeter record flow?
❑
❑ ❑
Does flowmeter appear to monitor accurately?
❑
❑ ❑
Comment:
Treatment Flow Measurement -Water Use Records Yes No NA NE
Is water use metered? ❑ ❑ 0 ❑
Are the daily average values properly calculated? ❑ ❑ 0 ❑
Comment:
Treatment Flow Measurement -Effluent Yes No NA NE
Is flowmeter calibrated annually? 0 ❑ ❑ ❑
Is flowmeter operating properly? ❑ ❑ ❑
Does flowmeter monitor continuously? ❑ ❑ ❑
Does flowmeter record flow? ❑ ❑ ❑
Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑
Comment: The HACH flowmeter was calibrated on 4-30-20 by Delta Systems Environmental.
Standby Power Yes No NA NE
Is automatically activated standby power available? 0 ❑ ❑ ❑
Page 3 of 7
Permit: WQ0024756 Owner - Facility: Fmb at the Grove LLC
Inspection Date: 11/18/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Comment: No comment.
• ❑ ❑ ❑
• ❑ ❑ ❑
❑❑❑■
Treatment Barscreen Yes No NA NE
Is it free of excessive debris? ❑ ❑ ❑
Is disposal of screenings in compliance? ❑ ❑ ❑
Are the bars spaced properly? ❑ ❑ ❑
Is the unit in good condition? 0 ❑ ❑ ❑
Comment: Screenings from the manual bar screen are removed as needed. The high-level float in the EQ
tank, following the manual bar screen, was activated. The audio alarm was not operable. ORC
received notification of alarm on his cell phone.
Treatment Activated Sludae
Is the aeration mechanism operable?
Is the aeration basin thoroughly mixed?
Is the aeration equipment easily accessed?
Is Dissolved Oxygen adequate?
Are Settleometer results acceptable?
Is activated sludge an acceptable color?
Comment: Aerators are controlled automatical
zone.
Treatment Clarifiers
Are the weirs level?
Are the weirs free of solids and algae?
Is the scum removal system operational?
Is the scum removal system accessible?
Is the sludge blanket at an acceptable level?
Is the effluent from the clarifier free of excessive solids?
Comment: No comment.
Treatment Return pumps
Are they in place?
Are they operational?
Comment: No comment.
Treatment Filters
Is the filter media present?
Is the filter media the correct size and type?
Yes No NA NE
■❑❑❑
■❑❑❑
■❑❑❑
❑❑❑■
❑❑❑■
■❑❑❑
the DO levels. A carbon source is added to the anoxic
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
■❑❑❑
Yes No NA NE
Yes No NA NE
■❑❑❑
❑❑❑■
Page 4 of 7
Permit: WQ0024756 Owner - Facility: Fmb at the Grove LLC
Inspection Date: 11/18/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Is the air scour operational? 0 ❑ ❑ ❑
Is the scouring acceptable? 0 ❑ ❑ ❑
Is the clear well free of excessive solids? 0 ❑ ❑ ❑
Is the mud well free of excessive solids and filter media? 0 ❑ ❑ ❑
Does backwashing frequency appear adequate? 0 ❑ ❑ ❑
Comment: Backwashing is done manually as needed. The high-level float was activated in the wet well and
the audio alarm was not operable. The operator was notified of alarm on his cell phone.
Treatment Disinfection
Yes No NA NE
Is the system working?
0
❑ ❑ ❑
Do the fecal coliform results indicate proper disinfection?
❑ ❑ ❑
Is there adequate detention time (>=30 minutes)?
❑
❑ ❑
Is the system properly maintained?
❑ ❑ ❑
If gas, does the cylinder storage appear safe?
❑
❑ ❑
Is the fan in the chlorine feed room and storage area operable?
❑
❑ ❑
Is the chlorinator accessible?
❑
❑ ❑
If tablets, are tablets present?
❑
❑ ❑
Are the tablets the proper size and type?
❑
❑ ❑
Is contact chamber free of sludge, solids, and growth?
❑
❑ ❑
If UV, are extra UV bulbs available?
❑
❑ ❑
If UV, is the UV intensity adequate?
❑
❑ ❑
# Is it a dual feed system?
❑
❑ ❑
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
❑
❑ ❑
If yes, then is there a Risk Management Plan on site?
❑
❑ ❑
If yes, then what is the EPA twelve digit ID Number? (1000-
If yes, then when was the RMP last updated?
Comment: No comment.
Record Keeping
Yes No NA NE
Is a copy of current permit available?
0
❑ ❑ ❑
Are monitoring reports present: NDMR?
❑
❑ ❑
NDAR?
❑
❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are application rates adhered to?
❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
❑ ❑ ❑
Are all samples analyzed for all required parameters?
❑ ❑ ❑
Are there any 2L GW quality violations?
❑
❑ ❑
Page 5 of 7
Permit: WQ0024756 Owner - Facility: Fmb at the Grove LLC
Inspection Date: 11/18/2020 Inspection Type: Compliance Evaluation
Reason for Visit: Routine
Is GW-59A certification form completed for facility?
❑
❑ ❑
Is effluent sampled for same parameters as GW?
0
❑ ❑ ❑
Do effluent concentrations exceed GW standards?
❑
0 ❑ ❑
Are annual soil reports available?
❑
❑ 0 ❑
# Are PAN records required?
❑
0 ❑ ❑
# Did last soil report indicate a need for lime?
❑
❑ 0 ❑
If so, has it been applied?
❑
❑ 0 ❑
Are operational logs present?
0
❑ ❑ ❑
Are lab sheets available for review?
❑
❑ ❑
Do lab sheets support data reported on NDMR?
❑
❑ ❑
Do lab sheets support data reported on GW-59s?
❑
❑ ❑
Are Operational and Maintenance records present?
0
❑ ❑ ❑
Were Operational and Maintenance records complete?
0
❑ ❑ ❑
Has permittee been free of public complaints in last 12 months?
0
❑ ❑ ❑
Is a copy of the SOC readily available?
❑
❑ 0 ❑
No treatment units bypassed since last inspection?
0
❑ ❑ ❑
Comment: Operational and maintenance log book was organized and complete.
End Use -Infiltration
Yes No NA NE
# Is the application High Rate or Low Rate?
High
Rate
Are buffers maintained?
0
❑ ❑ ❑
Are any supply wells within the CB?
❑
0 ❑ ❑
Are any supply wells within 250' of the CB?
0
❑ ❑ ❑
Is municipal water available in the area?
❑
❑ ❑
Are GW monitoring wells required?
0
❑ ❑ ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
0
❑ ❑ ❑
Are GW monitoring wells properly constructed, including screened interval?
0
❑ ❑ ❑
Is a usable green area maintained?
❑
❑ 0 ❑
Is the disposal site acceptable?
0
❑ ❑ ❑
Is the distribution equipment acceptable?
0
❑ ❑ ❑
Is the disposal site free of ponding?
0
❑ ❑ ❑
Is the disposal site free of breakout?
0
❑ ❑ ❑
Are the disposal sites free of solids, algae, etc.?
0
❑ ❑ ❑
Do the records show that the fields are properly maintained?
0
❑ ❑ ❑
Are the disposal sites free of vegetation?
0
❑ ❑ ❑
Do any surface water features appear to be adversely impacted by GW discharge?
❑
0 ❑ ❑
No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.?
0
❑ ❑ ❑
Page 6 of 7
Permit: WQ0024756 Owner - Facility: Fmb at the Grove LLC
Inspection Date: 11/18/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Comment: According to the permit, there is a water supply well located within 250 feet of the infiltration aree
This well is 225 feet deep, and therefore the 500 feet setback does not apply. Vegetation has
been removed from the drip field, a landscape cloth cover installed and the drip lines raised to
the surface as required by the schedule in the new permit issued 10-28-19. Pea gravel has been
added as a cover. Signs are posted at every corner of field restricting public access. Monitoring
Well #1, located on the corner of Atlantic Blvd and East Drive, was found damaged during the
last sampling event. A new well will need to be drilled according to 15A NCAC 02C .0108 rules a
soon as possible to continue permit monitoring requirements.
Page 7 of 7