Loading...
HomeMy WebLinkAboutWQ0042099_Application (FTSE)_20201123Permit Number WQ0042099 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, $ Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow Facility Name Swansboro Bojangles Public Force Main Location Address Owner Owner Name Onslow Water and Sewer Authority Dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance 11/4/2020 KCONSULTING GROUP, PI_LC To: NCDEQ-DWR - Wilmington Regional Office Water Quality Regional Operations Section 127 Cardinal Drive Ext. Wilmington, North Carolina 28405 TRANSMITTAL LETTER DATE: PROJECT NO. November 2, 2020 20018 ATTENTION: RECEIVED Dean Hunkele SUBJECT: Noy o 4 2n2n Bojangles Restaurant Fast Track Sewer NCDEQ W LMINGTON RO ONWASA, Onslow County, North �aroryina WE ARE SENDING YOU: ® Attached El Under Separate Cover Via: the following items: ❑ Copy of Letter ® Plans ❑ Specifications ® Other: ❑ Shop Drawings ❑ Prints ❑ Permits ❑ Change Order ❑ Reproducible ❑ Samples COPIES DATE DWG. # DESCRIPTION 1 10/28/2020 Fast Track Sewer System Extension Application 1 10/28/2020 Flow Tracking for Sewer Extension Application 1 11/2/2020 Application Fee ($480.00) 1 Site Map 1 11/2/2020 Fast Track Cover Letter - ONWASA THESE ITEMS ARE TRANSMITTED AS CHECKED BELOW: ® For Approval ❑ Approved as Submitted ❑ Submit copies for approval ❑ For Your Use ❑ Approved as Noted ❑ Submit copies for distribution ❑ As Requested ❑ Returned for Corrections ❑ Return —corrected prints ® For Review & Comment ! ❑ Disapproved ❑ Other: COMMENTS: Please call me at 252-565-1017 should you have questions or require additional information. COPY TO: Da4'V VWRe4-k, P.E. Signature KCONSULTING GROUP, PLI_C ENGINEERS & PLANIaCk_, November 2, 2020 Mr. Dean Hunkele NCDEQ - DWR - Fast Track Sewer Extension 127 Cardinal Dr. Ext Wilmington, NC 28405 RE: Bojangles Restaurant, Swansboro, NC NCAC 02T.0300 Fast Track Sewer System Extension ONWASA, Onslow County, NC Dear Mr. Hunkele, Enclosed is a sewer extension application with supporting documentation for the sewer system extension in Onslow County. The proposed extension consists of approximately 1500 linear feet of force main to serve a new quick service restaurant. The restaurant will have its own, separately permitted private pump station. All additional flow associated with this project will be permitted in the separate application for the pump station. The proposed force main will discharge to an existing force main owned and operated by ONWASA. The enclosed documents include the following items: • Check in the amount of $480.00 • Fast Track Sewer System Extension Application • Flow Tracking for Sewer Extension Applications • Site Map On behalf of the applicant, ONWASA, we respectfully request that you grant a permit for construction of this sewer system. With best regards, WArkConsulting Group, PLLC J. Dantzler Withers, P.E. Project Manager 2755-B Charles Boulevard, Greenville, NC 27858 252-558-0888 www.arkconsultinggroup.com State of North Carolina R Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 -FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W kQ U -1 k� 1 (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Onslow Water and Sewer Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: David M. Mohr. PE per 15A NCAC 02T .0106(b) Title: Chief Operations Officer 4. Applicant's mailing address: 228 Georgetown Road City: Jacksonville State: NC Zip: 28540- 5. Applicant's contact information: Phone number: 910 937-7550 Email Address: dmohr ,onwasa.com II. PROJECT INFORMATION: 1. Project name: Boiangles' Swansboro 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00_ and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Onslow 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.708361 ° Longitude:-77.162767' 5. Parcel ID (if applicable): 060467 and 055489 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: J. Dantzler WithersLicense Number: 38746 Firm: Ark Consulting Group, PLLC Mailing address: 2755-B Charles Blvd. City: Greenville State: NC Zip: 27858 Phone number: 252 565-1017 Email Address: dan.withers(narkconsultinggroup.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Swansboro Wastewater Treatment Plant Permit Number: W00023261 Owner Name: Onslow Water and Sewer Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. PermitNumber(s): WQ-o-,�31qDownstream (Receiving) Sewer Size: 2 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00249 Owner Name(s): Onslow Water and Sewer Authority FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:)No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Aereement (FORM: DEVI been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Pronertv Owners' Association. has an Operational Agreement (FORM: HOA) been attached? ❑ Yes [-]No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 0 % Domestic/Commercial 100 % Commercial 0 % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes CyNo 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? [-]Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.01140 Daily Design Flow a,s No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0.00 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 2 1125 SCH 40 PVC 2 350 DR-9 IPS HDPE 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & W ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "*Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet *"Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any buildina foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [-]Yes ❑ No ® N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents 2. Professional Engineer's Certification: I J. Dantzler Withers, PE attest that this application for (Professional Engineer's name from Application Item III.].) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, OaoicA M. A&ri�F'Z' Oorro(i 1 Dh�icPl attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: r)10 Date: /0�04PZ0 FORM: FTA 04-16 Page 5 of 5 USGSU.S. DEPARTMENT OF THE INTERIOR HUBERT QUADRANGLE uJ U.S. GEOLOGICAL SURVEY NORTH CAROLINA sclence lure clranging worts 7.5•MINUTE SERIES J ` !�ny LONGWOOD DR '(��•+'�� ",\ l t c'` oy f a � � jSO� N%,NNIE N . fqN II _� I - }�, 8YI y L pOp 4 7 RO CH )5 lit` �.� �..+/� ��� ♦ //////���''�� / 4NNf[nr4RKrR r� � 'yOUPON DR 0 pI l i � � r ` ,1 RIU 1 JAW= �j"� oai f MN, G e 1))MIL6 HUBERT, NC ]R� 2019 COMWL INTERNAL 5 FEET UIMORN,WD Mf NORM NORTH ARERI4R WJMCA. DAWKOf 19H OFCLW.LiXN, AT CENTERUNi[R OFF MEET PrOj60t Mgr.: JDW Project No.: 20018 NC License: R5199 SITE LOCATION PLAN EXHIBIT Drawn By: TGN Scale: ASSHOWN ..�D CONSULTING Chocked BY: �pyy Date: g�q�4040 ie"'�C �KGROUP,PLLC SWANSBORO BOJANGLES Engineere & Planners EROSION CONTROL PLAN A 2755-B Charles Blvd. I Greenville, NC 27858 SWANSSORO, ONSLOW COUNTY, NC