Loading...
HomeMy WebLinkAboutWQ0042103_Application (FTSE)_20201124Central Files: APS _ SWP 11 /10/2020 Permit Number WQ0042103 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRuIe Permitted Flow Facility Name Contract 118 South Shore Drive Extension Location Address Owner Owner Name Town of Morehead City Dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance 11 /9/2020 MCDAVID ASSOCIATES, INC. INC. Engineers • Planners • Land Surveyors CORPORATE OFFICE GOLDSBORO OFFICE (252) 753-2139 • Fax (252) 753-7220 (919) 736-7630 • Fax (919) 735-7351 E-mail: mai@mcdavid-inc.com E-mail: maigold@mcdavid-inc.com 3714 N. Main Street • P.O. Drawer 49 109 E. Walnut Street • P.O. Box 1776 Farmville, NC 27828 Goldsboro, NC 27533 November 4, 2020 Mr. Dean Hunkele 7E( EIVEC, Wilmington Regional Office Water Quality Section NOV 0 9 2020 127 Cardinal Avenue Wilmington, NC 28405 NCDE0 WILMINGTON Ro SUBJECT: Transmittal of Fast Track Sewer Application Contract No. 118 —South Shore/Florida Sewer Extension Town of Morehead City Carteret County, NC Dear Mr. Hunkele: Enclosed please one original and one copy of the following items: 1. Check in the amount of $480.00 2. Fast Track Application (FTA 04-16) (1 original and 1 copy) 3. Flow Tracking / Acceptance (FTSE 10-18) 4. Site Maps The proposed work includes installation of approximately 177 LF of 8" PVC gravity sewer lines to serve one proposed new home. Your review and approval will be appreciated. If you have any questions concerning this, please do not hesitate to contact me. Sincerely, McDAVID ASSOCIATES C. D. E. "Trey" Gurley, III, P Goldsboro Office DEG: Enclosures cc: Town of Morehead City \\G-Gl0S\D1005\FTL\2020 1 201104 MHC-CNI 18 South Shore -Florida Sewer Ext-Fast Track Application .docx State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number. 1 U q?. Q -3 (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Morehead City (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Ryan Eggleston per 15A NCAC 02T .0106(b) Title: City Manaeer 4. Applicant's mailing address: 706 Arendell Street City: Morehead City State: NC Zip: 28557- 5. Applicant's contact information: Phone number: 252 726-6848 Email Address: Daniel.Williams@moreheadcitync.org I1. PROJECT INFORMATION: 1. Project name: Contract 118 - South Shore/Florida Sewer Extension 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000 and issued date: _ If new construction but part of a master plan, provide the existing pennit number: W000 3. County where project is located: Carteret 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.7260' Longitude:-76.7861° 5. Parcel ID (if applicable): 636618429351000 6. (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: David E. Gurley, III License Number: 22956 Firm: McDavid Associates, Inc. Mailing address: P. O. Box 1776 City: Goldsboro State: NC Zip: 27533- Phone number: (252) 736-7630 Email Address: ftl@mcdavid-inc.com IV. WASTEWATER TREATMENT FACILITY (W WTF) INFORMATION: 1. Facility Name: Morehead City Municipal W WTP Permit Number: NCO026611 Owner Name: Morehead City V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQNot Applicable Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS_ Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ®No ➢ If Yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(fll Daily Design Flow °,b No. of Units Flow residential lot 360 gal/unit 1 360 GPD gall GPD gal/ GPD gall GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .01 14(b), (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I SA NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 360 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 177 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I . Pump station number or name: Not Applicable 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B). ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in ISA NCAC 02T .0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: N Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webuage ➢ If noncompliance with 02T.0305(fl or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No N N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No N N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes N No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer PermittingBranch ranch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? N Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes N No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I SA NCAC 02T, the Minimum Design Criteria for the Permittingof Stations and Force Mains (latest version), and the Gravitv Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents 2. Professional Engineer's Certification: I, David E. Gurley, III attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and dat : �tC A R 0� 'ESS/p •�y% _� O.oQ ti•.9 2:Q7 SEAL 22956 Lj••.,GIN, �.� 3. Applicant's Certification per 15A NCAC 02T .0106(b): Ryan Eggleston, City Manager attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil po&Itrgc:up_1o,$25,000 per violation. Signature: Date: November 3, 2020 FORM: FTA 04-16 Page 5 of 5 Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Town of Morehead Project Name for which flow is being requested: CN 118-South Shore/Florida Sewer Ext. More than one FTSE maybe requiredfor a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposer! wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Town of Morehead b. WWTP Facility Permit #: NC0026611 lava, All flows are in MGD c. WWTP facility's permitted flow 2.5 d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request 0.00036 g. Total actual and obligated flows to the facility It. Percent of permitted flow used II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pO, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** PS 14 N/A 0.576 0.230 0.090 0.00 0.090 .140 PS 12 N/A 1.296 0.518 0.183 0.00 0.183 .335 PS 10 N/A 2.664 1.066 0.593 0.057 0.650 .416 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Unknown Downstream Permit Number: Unknown Page 1 of 6 FTSE 10-18 III. Certification Statement: I Daniel Williams certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signature Public Services Director Title of Signing Official November 3, 2020 Date Page 2 of 6 FTSE 10-18 D COUNTRY CLUB RD AVE I ----I SCALE IN FEET : 1" = 500' 500 0 500 1000 %"'h 1 7 { I I {i` r 1 I EXISTING o" owr MANHOLE PROPOSED PROPOSED g" PVC MANHOLE SANITARY SEWER CITY --� sfiel TOWN OF MOREHEAD CITY SOUTH SHORE/FLORIDA SEWER EXTENSION (USGS MAP: MANSFIELD, NC) 4�1 cm 6 a cm. °f Ev fhl .y ram.^ y . ;r 1 .) V+' uo y �9 Tax Parcel Information: Carteret County, N . C .= Owner: PERRY GRANDCHILDREN LLC Current PIN: 636618429351000 Site Address: 4805 S SHORE DR MOREHEAD CITY Mailing Address: KINSTON NC 285011475 Legal Description: L SOUTH OF SHORE DR-BOGUE SOUN Prior PIN: City Limits: MOREHEAD CITY Rescue District: Fire District: Tax District: 1351 Township: MOREHEAD Use: VACANT Land Value: $374,935 NBHD: 510002 Bldg Htd Sq Ft: Bldg Value: $o Bldg Tot Sq Ft: o Other Value: $o •1 Total Value: $374,935 Sale Price: $0 Deeded Acres: 0.577 Plat Ref: 1 / 13 Deed Ref: 1662 / 489 Year But t: Noise Level: AICUZ Zone: GIS Acres: 0-542 Roll Type: R Deed Date: 20200211 Bedrooms: Bathrooms: The information displayed by tNs website is prepared for the imentory of ree nformabon sources shwc be wrreufied for venficatbn fthe informalon m r iv=d6s ft Printed November 2, 2020' i iction and is wnpiledfmm recorded deeds, plats, and other pudic records and data. Users of this infonnabon are hereby notified that the afaementionad public prirrery wMyassumes no legal responsibility for the information wntaned on th'e site. CarteretCwntydmsmtguamMeethatihedat wdmapsewlwswilbeavailable Wo m