HomeMy WebLinkAboutNCG510335_Regional Office Historical File Pre 2018 (2) A • .A,
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Michael F. Easley, Governor William G. Ross, Jr., Secretary
Alan W. Klimek, P.E., Director
February 10, 2006
Pete Overton
Pacemaker Leasing
543 Cox Road, Suite C
Gastonia, NC 28054
Subject: NPDES Permit NCG510000 renewal
Certificate of Coverage (CoC) NCG510335
Gilliland's site
Gaston County
Dear Permittee:
The facility listed above is covered under NPDES permit NCG510000 for discharge of remediated
groundwater. NCG510000 expires on September 30, 2006. Federal (40 CFR 122.41) and North Carolina (15A
NCAC 2H.0105(e))regulations require that permit renewal applications must be filed at least 180 days prior
to expiration of the current permit. If you have already mailed your renewal request, you may
disregard this notice.
To satisfy this requirement, the Division must receive your renewal request postmarked no later than
April 3, 2006. Failure to request renewal by this date may result in a civil assessment of at least $500.00.
Larger penalties may be assessed depending upon the delinquency of the request.
If any discharge from the remediation system will occur after September 30, 2006,your CoC must be
renewed. Discharge of wastewater without a valid permit would violate North Carolina General Statute 143-
215.1; unpermitted discharges of wastewater may be assessed civil penalties of up to $25,000 per day.
If you have halted remediation activity due to lack of trust fund money, but your site ranking from the
Aquifer Protection Section requires future remediation & discharge, your CoC must be renewed.
If all discharge has ceased at your facility and you wish to rescind this CoC [or if you have other
questions], contact me at the telephone number or e-mail address listed below.
Sincerely,
to- 4, VAAN7, )7-
Charles H.Weaver,Jr.
NPDES Unit
FEB 2 7 2006
cc: Central Files
NPDES File
1617 Mail Service Center,Raleigh,North Carolina 27699-1617 One
512 North Salisbury Street,Raleigh,North Carolina 27604 NorthCarolina
Phone: 919 733-5083,extension 511/FAX 919 733-0719/charles.weaver@ncmail.net Naturally
An Equal Opportunity/Affirmative Action Employer—50%Recycled/10%Post Consumer Paper
•
Groundwater Management Associates, Inc.
101-E Woodwinds Industrial Court
Cary, North Carolina 27511
(919) 481-2631
August 22, 1994
Ms. Carolyn McCaskill
Permits & Engineering
NC Department of Environment, Health and Natural Resources
Division of Environmental Management
512 North Salisbury Street
Raleigh, North Carolina 27611
Re: General NPDES Permit Application
Pacemaker Leasing Co./Gilliland's Place
Springwood, Gaston County
Dear Ms. McCaskill:
Enclosed are three copies of an application for a general NPDES permit
for a discharge of treated groundwater at the above-referenced site. The
application includes sizing criteria, plans, and specifications for the
groundwater recovery and treatment systems. An application fee of $400 is
also enclosed.
Please contact me at (919) 481-2631 if you require more information.
Sin • -rely
010JiJ. Wi , P.E.
E nme al Engineer
cc: P. Overton
enclosures ~�
T7 cz.
1 1
�s3GtTt•
.Esi '7;1)
State of North Carolina
Department of Environment, Health and Natural Resources
Division of Environmental Management
512 North Salisbury Street•Raleigh,North Carolina 27611
James G.Martin,Governor A.Preston Howard,Jr.,P.E.
William W.Cobey,Jr.,Secretary Acting Director
NOTICE OF INTENT
National Pollutant Discharge Elimination System
Application for Coverage under General Permit NCG510000;Groundwater remediation projects
designed to treat petroleum contaminated groundwater.
1. Name,Address,location,and telephone number of facility requesting Permit.
A. Official Name: Pacemaker Leasing Co/Gilliland's Place
B. Mailing Address: 543 Cox Road
(1)Street Address; Post Office Box 2359
(2)City; Gastonia.
(3)State; North Carolina
(4)Zip; 28053-2359
(5)County; Gaston
C. Location. (Attach map delineating general facility location)
(1)Street Address; 1021 Hickory Grove Road
(2)City; Springwood
(3)State; North Carolina
(4)County; Gaston
D. Telephone Number; ( 704 ) 867 - 7281
2. Facility Contact:
A. Name; Pete Overton
B. Title; Real Estate Manager
C. Company Name; Pacemaker Leasing Co.
•
D. Phone Number; ( 704 ) 867 - 7281
3. Application type (check appropriate selection):
A. New or Proposed; X
B. Existing; If previously permitted,provide permit number
and issue date
C. Modification;
(Describe the nature of the modification):
4. Description of discharge
A.Please state the number of separate discharge points.
1,[]; 2,[]; 3,[]; 4,[]; ]•
Page 1
B.Please describe the amount of wastewater being discharged per each separate discharge point:
1 000gallons per day(gpd) 2: (gpd) 3: (gpd) 4: (gPd)
C.Check the duration and frequency of the discharge,per each separate discharge point:
1. Continuous: x
2.Intermittent(please describe):
3. Seasonal(check month(s)the discharge occurs):January[l;February[];March[];April[],
May[];June[];July[];August[];September[LOctober[]:November[];December[I.
All
4. How many days per week is there a discharge?(check the days the discharge occurs)
Monday[], Tuesday[], Wednesday[], Thursday[],Friday[], Saturday[], Sunday[].
ALL
5. How much of the volume discharged is treated?(state in percent) 1 00%
D. Describe the type of wastewater being discharged per separate discharge point. Specify what is
being removed and products recovered. This includes a listing of any chemicals found in
detectable amounts with the maximum observed concentration reported. The summary of
analytical results containing this maximum value should also be submitted (i.e.the listing,not
the graphical scan). The most recent sample must be no older than one year previous to the date
of this application. The following volatile organic compounds should be included along with
any suspected fuel additive;
1. Benzene*;
2. Toluene*;
3. Ethylbenzene*;
4. Xylene*;
5. Lead;
6. Methyl tert-butylether. (MTBE);
7. Dibromoethane (EDB);
8. 1,2-dichloroethane;
9. Isopropyl ether;
10. Naphthalene;
11. Phenol;
*(An EPA approved method capable of detection levels to 1 ppb should be used to detect these
compounds).
E. Please check the appropriate type of treatment being used to treat the groundwater;
1. Oil/Water Separator; X
2. Air Stripper; X
3. Diffused Aeration;
4. Activated Carbon Absorption; x
5. Other(spedfy);
6. Separately,please describe in detail(size,volume,capacity,design flow through treatment,
etc.)each type of treatment that was checked in 1 through 5. Include,if any,the
manufacturer's information on each type of treatment.Also provide the removal efficiency of
each compound detected for the project,if known.Give design specifics(i.e.design volume of
each unit,materials used in air stripper,etc.). Existing treatment facilities should be
described in detail and design criteria or operational data should be provided(including
calculations) to ensure that the facility can comply with requirements of the General Permit.
Please include model and calculations used in determining the design requirements for the air
stripper.
7. What are the well sizes and how many exist.
8. Please state the pump sizes and their location in relation to the treatment used in part 2.E.
9. Please explain what fail-safe measures,such as audible and visual alarms or automatic
shutoff systems,are provided to ensure no system failures.
10. Is there an access to the effluent for sampling?(either an open pipe or a valve to obtain a
sample)
Page 2
rr
OTE: Construction of any wastewater treatment facilities require submission of three (3) sets of plans
and specifications along with their application. Design of treatment facilities must comply
with requirement 15A NCAC 2H .0138. If construction applies to the discharge, include the
three sets of plans and specifications with the application.
5. What is the nature of the business applying for this permit. Petroleum Retailer
South Fork of
6. Name of receiving water or waters; Catawba River Classification: _WS-5
(Attach a USGS topographical map with all discharge point(s) clearly marked)
7. Is the discharge directly to the receiving water?(Y,N) N
If no, state specifically the discharge point. Mark clearly the pathway to the potential receiving
waters on the site map. (This indudes tracing the pathway of the storm sewer.to its discharge
point,if a storm sewer is the only viable means of discharge.)
8. Please address possible non-discharge alternatives for the following options:
A.Connection to a Regional Sewer Collection System;
B. Subsurface Disposal;
C. Spray Irrigation;
9. I certify that I am familiar with the information contained in the application and that to the best of
my knowledge and belief such information is true,complete,and accurate.
Printed Name ofPersonSigning Pete Overton
Title Real Estate Manager
Date Application Si d29 t
Signature of Applicant
NORTH CAROLINA GENERAL STATUTE 143 215.6 B (i) PROVIDES THAT:
Any person who knowingly makes any false statement, representation, or certification in any
application,,record,report,plan or other document filed or required to be maintained under Article 21 or
regulations of the Environmental Management Commission implementing that Article,or who falsifies,
tampers with or knowingly renders inaccurate any recording or monitoring device or method required to
be operated or maintained under Article 21 or regulations of the Environmental Management
Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to
exceed$10,000,or by imprisonment not to exceed six months,or by both.(18 U.S.C.Section 1001 provides
a punishment by a fine of not more than$10,000 or imprisonment not more than 5 years, or both, for a
similar offense.)
Notice of Intent must be accompanied by a check or money order for$400.00 made payable to the North
Carolina Department of Environment, Health, and Natural Resources. Mail three (3) copies of entire
package to:
Division of Environmental Management
NPDES Permits Group
Post Office Box 29535
Raleigh, North Carolina 27626-0535
Page 3
//lir
._9 6 c)_.
SOC PRIORITY PROJECT: Yes No X
To: Permits and Engineering Unit
Water Quality Section
Attention: Charles Alvarez
Date: -November 3, 1994
NPDES STAFF REPORT AND RECOMMENDATION
County: Gaston
MRO No. : 94-209
Permit No. NC0084484
PART I - GENERAL INFORMATION
1. Facility and Address: Pacemaker Leasing Co./Gilliland's Place
543 Cox Road
Gastonia, North Carolina 28053
2 . Date of Investigation: 11-01-94
3. Report Prepared By: Samar Bou-Ghazale, Env. Engineer I
4 . Persons Contacted and Telephone Number: Ms. Mary Facciolo,
Staff Engineer with Groundwater Management Associates, Inc. ;
tel# (919) 481-2631
5 . Directions to Site: From the junction of I-85 and Highway 7
in McAdenville travel east on Highway 7 (Main Street)
approximately 0.7 mile to the intersection with Wesleyan Road
and Hickory Grove Road. Turn left on Hickory Grove Road (SR
2000) and travel approximately 1.3 mile to the intersection
with Beam Road. Gilliland's Place is located on Hickory Grove
Road just south of the Beam Road intersection.
6 . Discharge Point(s) . List for all discharge points:
Latitude: 35° 16 ' 13" Longitude: 81° 03' 42"
Attach a U.S.G.S. map extract and indicate treatment facility
site and discharge point on map.
USGS Quad No. : F 14 SE USGS Quad Name: Mount Holly, N.C.
7 . Site size and expansion are consistent with application?
Yes X No If No, explain:
8. Topography (relationship to flood plain included) : Sloping
south toward an intermittent stream at the rate of 2 to 10%.
The site is not located in a flood plain.
//lir
Page Two
9 . Location of nearest dwelling: The nearest dwelling is located
approximately 100 feet from the discharge point.
10. Receiving stream or affected surface waters : Unnamed
Tributary to the South Fork Catawba River.
a. Classification: WS IV
b. River Basin and Subbasin No. : Catawba River Basin;
030834
c. Describe receiving stream features and pertinent
downstream uses: Discharge will take place into an
intermittent stream on the south side of the site. This
stream flows through an undeveloped area prior to
entering the South Fork of the Catawba River.
PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS
1 . a. Volume of wastewater to be permitted: 0. 144 MGD (Ultimate
Design Capacity)
b. What is the current permitted capacity of the wastewater
treatment facility? N/A.
c. Actual treatment capacity of the current facility
(current design capacity) ? N/A.
d. Date(s) and construction activities allowed by previous
Authorizations to Construct issued in the previous two
years: N/A.
e. Please provide a description of existing or substantially
constructed wastewater treatment facilities : N/A.
f. Please provide a description of proposed wastewater
treatment facilities: The proposed groundwater treatment
system will consist of monitoring wells, recovery wells,
oil/water separator, air stripper, and an activated
carbon adsorption unit.
g. Possible toxic impacts to surface waters: Effluent from
similar facilities have failed toxicity testing.
.
h. Pretreatment Program (POTWs only) : N/A.
2 . Residuals handling and utilization/disposal scheme: Generation
NPDES Permit Staff Report
Version 10/92
Page 2
//lir
of residuals is not expected.
Page Three
3. Treatment plant classification (attach completed rating
sheet) : Proposed, no rating given.
4 . SIC Code(s) : 5541
Primary: 66
Main Treatment Unit Code: 56000
PART III - OTHER PERTINENT INFORMATION
1 . Is this facility being constructed with Construction Grant
Funds or are any public monies involved (municipals only) ?
N/A.
2 . Special monitoring or limitations (including toxicity)
requests: Toxicity may need to be limited.
3. Important SOC, JOC or Compliance Schedule dates: (please
indicate) N/A.
4. Alternative Analysis Evaluation: Has the facility evaluated
all of the non-discharge options available. Please provide
regional perspective for each option evaluated.
Spray irrigation: The use of a spray irrigation was evaluated
and found not to be an alternative.
Connection to regional Sewer System: Not an economically
feasible alternative according to applicant. The nearest
sanitary sewer system is located approximately one mile from
the site.
Discharge to an infiltration gallery: The use of an
infiltration gallery was evaluated and found not to be a
viable alternative given the presence of bedrock at a shallow
depth.
5 . Air Quality and/or Groundwater concerns or hazardous waste
utilized at this facility that may impact water quality, air
quality or groundwater? Contaminated groundwater already
exists at the site. No hazardous waste will be generated.
Air Quality Permit for this facility is not required. However,
registration with the Air Quality Section is required.
NPDES Permit Staff Report
Version 10/92
Page 3
//lir
PART IV - EVALUATION AND RECOMMENDATIONS
Pacemaker Leasing Company is requesting an NPDES Permit for
the discharge of treated groundwater resulting from a leaking
underground storage tank.
The proposed method of treatment is typical of treatment
methods used by the petroleum industry for groundwater remediation
activities.
Field investigation revealed that the treatment system is
being constructed approximately 15 feet from a residence. The
treated water will then be piped across Hickory Grove Road to the
receiving stream, an intermittent stream that flows through an
undeveloped area prior to entering the South Fork of the Catawba
River. Due to the proximity of a dwelling, this Office is
recommending that Pacemaker Leasing Company obtain written approval
from the dwelling owner prior to constructing any facilities, since
nuisance conditions (ie - noise) may occur.
The effluent from similar facilities has been known to fail
toxicity testing.
It is recommended that the NPDES Permit be issued once the
above mentioned concerns regarding nuisance and toxicity have been
addressed.
(...44;4:, �L— //- 3 - 9 4-
Signature of Repo Preparer Date
7) 2...e„._ e , /// s
Water Quality gional Supervisor Date
NPDES Permit Staff Report
Version 10/92
Page 4
/7 / -
_> ..,-2.1 .• Ike\ 4#‘;,6 I iii_
•
Alk
. ,i .. i _Nilo", . //(--/
joi
• -';/) 1 •.;;•) -1---() ? \----\ -------------H''4S \:t
,cc
-71--' • • / --'---,_.,_,•__, 1° •/ , -....,, I
-Ica /; • `b /
.L. i ,__..
i
i
I . /1- -,,
1 _,. ,---." / : ,/ ---,4, I •
I 7\__r_ ,/ /4"' r
.'.2-N\ v (7,-,c ,..)„..),..v.:-• •
,,,::: )___ 1 . I,. ,,
-0. / ,67\;.. N'e,„.____/--------'\__, : ( .....2,-„.,. -..
..„ ,—..._"___/ _--. . ) I '7,*,, .\--1( .
'''V-sl : .1 is,--/- , --
v„,....___„' _ _.,„_.• /2 • ,/,, 75 • . , e1Teril ...... II ',1;----_---- __\ .7/
•
�'�/ o`t` 1 cl .� ,"" i�:\.r , ? Epp / /.�! • s_^
'''ss - , II V,, fr•-Y/7 • 44; • 2r ' 4 .., _
' - - /i? / ' Cenkili 4• .•' �,n � T \ -E/7 1 /-( - A
i /, „...----- --- .- / *.' • ' 1 ,,,„,„,..:Iir..... .„ 0 .......0 ipir- .• liplii .-
2/,
--700 \ ‘-.` ••f.„?•c, g,, •\ .r-; / ° /i ft 4, '—, _•' - •- /;•mow- ''' 's \ 1
7- 700
\ �. \
p -.-.:;.\":,7.,, 1..... ..,,i j 1_,/,.46,,- 1----\/"----\,tb<.,N . (...____ IN,Atii,AI,S\ ,,,r.=_:,,}_i___,. ___,_,..:_,.,
ci:elots. 4N, 4,;#\''' :
0 J�r /, ` f .� -�-' ; . \'� ) S , o � \�'1 / J vJ /) •Tank ....„:._„-_,, , 8 1 , . 1
. :::. •:- ,,,1,1 1\ ‘ ' , -\\,1`-'.. *., \ „...-----.7.,..-----:.------- - . \.1,.../,...: Z.' ,', ' (..) i ,- ,„,•.'. . \ilk \I ?:7---.1--._.,- • • '1°°
:?- 31/';DNO416.11114'C,
sC =- Cris:,...r. g`,,) ��., j J IIIJJJ ���-----'.. O� �n .`� 1•/ /j , / /6�
-7.
l " i.�'� : �� �Igi
/ / i-----• �" 7 Nam•• \.FERS7yt�
„ , ......„ . _----1
•
. Av, ',I � •_.. 11.'4 `^ i, I . '— �/ nq,�'- I Fir _� " �0 /��� ��/ 11A',,ez Gt—
' �. Widen 2000 9� '`�' -"'' I a,�`734• -
Water \ .-) l y ' / ' - j h / WStgr j'�
�,• ® :'k����• \�/1 ., ( / ':�•� �� ,. ,-� c,� �, / !Tan ' 2\`. <��
00 '� \ b I e./ \ ea'
' .1)Th \*. : ••._; - •
• ir-----1114• I
/ . • /, (,ardans ^_ L �� _ / crca f it • 1,r I:i , \ ��.
,....(
.•i i ')i1 /�5� \fir./ /, / \ \ •) JKH:',Theater ')i , �•.`... ■ _ PIF
•
,„ -,-;.._;,„ T,,c--- . i ; t -:
• ls\fkvages-----;-/(--3
VI ' • �' I � y' ,1 'e. .n' •;; ) J � '' r, vim . +. c%• \ irsoir •/tfr•• _:_\ ,Cem 10 n r�lj'
/•
— �1�... \,�: .I; .\. 1'� , ' die -
L�L� i 3} •��i'/ �. <\ \• '�9tsd' T6`ers ••the Mein=/�•-- °t`the� /� • r.
7�,�� 4, ,•. : 1..,.,'•JJJ i gib\ ,• •' (r ^, ..� .r u sect e.rt .•�...
492 5' 493 1 494(CLOVER 1:62 00/ 495 496 •2'30"
4754//
SCALE 1:24000
I 7 0 1 MILE
I—� I ' I i
1000 0 1000 2000 3000 4000 5000 6000 7000 FEET
1---I 1-4 I-1 --, I
I 1
to of North Carolina ,
epartment of Environment,
Health and Natural Resources 02i • •
Division of Environmental Management
7 -0 twig,
James B. Hunt, Jr., Governor ��
Jonathan B. Howes, Secretary , �, E D i H A. Preston Howard, Jr., P.E., Director �"[ L--J Et,
r ENVIRONMENT, HEALTH,
�v & NATURAL RESOURCES
��� �x 1 i(r \ September 23, 1993
r�, V �} SEP 9R 1994
Mr. Pete Overton
'Pacemaker Leasing Company
4 DIVISION OF ENVIRONMENTAL MANAGEMENT
PO Box 2359 MOORESVILLE REGIONAL OFFICE
Gastonia, NC 28053-2359
Subject.: Application No. NC0084484
Additional Information Request
Gilliland's Place
Springwood
Gaston County
Dear Mr. Overton:
The Permits and Engineering Unit has completed a preliminary engineering review of the subject
application.
The following items must be addressed before we can complete our review:
1) An Authorization to Construct processing fee of$150.00 is needed to process the plans
for the above named facility.
2) If submitted by someone other than the owner, a letter of Delegation of Authority from
the property owner or officer of the corporation to you to serve as the agent to sign the
permit application for the facility.
Refer to the subject permit application number when providing the requested information. Please
submit two copies of all information to my attention at the address below. Also, please
note that failure to provide this additional information within 30 days of the date of this letter, will subject
your application to being returned as incomplete, in accordance with 15A NCAC 2H .0208.
I am, by copy of this letter, requesting that our Regional Office prepare a staff report and
recommendations regarding this discharge.
P.O. Box 29535, Raleigh,.North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496
An Equal Opportunity Affirmative Action Employer S0% recycled/ 10% post-consumer paper
Seprr. Pete Overton
M
tember 23, 1994
Page Two I i
If you have any questions on this matter, please call me at 919/733-5083.
Sincerely,
/, /r.
Charles A. Alvarez
Environmental Engineer
NPDES Group
cc: gligilla1111.111.1111111111ace
Permit File NC0084484
Groundwater Management Assoc., Inc.