Loading...
HomeMy WebLinkAboutWQ0042070_Application (FTSE)_20201022Is State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300— FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: V6 a�a (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: t L C 1. Applicant's name: DLH Development (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ IndividuaI fz Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State;'County ❑ Municipal ❑ Other 3. Signature authority's name: David Haskins per .15A NCAC 02T .0106(b) Title: Registered Agent hli�"�i�"�A401Ks2+' 4. Applicant's mailing address: 3605 Hwv 96 City: Oxford State: NC Zip: 27565- 5. Applicant's contact information: Phone number: 9( 19) 691-3714 Email Address: trabarhomesllc(@, mg ail.com IL PROJECT INFORMATION: I . Project name: Owen's Ridge Subdivision 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Pennit/Project If a modification, provide the existing permit number: WQ00� and issued date: n d If new construction but part of a master plan, provide the existing permit number: WQ00 ;;J 3. County where project is located: Granville 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.205096' Longitude:-78.724880' Q-4 < 70 5. Parcel ID (if applicable): 9864665555 (or Parcel ID to closest downstream sewer) o' N v III. CONSULTANT INFORMATION: 0 �. I . Professional Engineer: Chad E Abbott License Number: 036242 Firm: C3 Design & Engineering, PLLC' Mailing address: PO Box 0361 City: Creedmoor State: NC Zip: 27522- Phone number: (9j 9) 625-7368 Email Address: chad c3desi nen .com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: SGWASA W WTP Permit Number: NCO026824 Owner Name: SGWASA V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: inch S%stem Wide Collection 5%.stem Permit Numbers iif. applicable: WQCS_ OwnerName(s): SGWASA FORM: FTA 04-16 Page 1 of VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational .Ailreement [FORM. DEV1 been attached? ®Yes [:]No ❑NIA 3. If the Applicant is a Home Prppertv,Owners' Association, has an Operational A grVment FORM: H A been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply)- ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School I preschool / day care ❑ Medical I dental I veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses I offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial _% Commercial _I % Industrial (.See 15A N CAC 02TAI03129D f Is there a Pretreatment Program in effect? ❑ Yes [:]No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 14(-Q? ❑ Yes ®No ➢ If provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f}l Daily Design Flow'-b No. of Units Flow Single Family Residential (9 Lots with 3 BR/Lot)+ 88 gal/BR 27 2 376 GPD gall GPD gall GPD gal/ GPD gal/ GPD gall GPD Total 2,376 GPD a See 15A NCAC 02T .01 I4(b)- (d),_(e)(1) and (0(21 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified (in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 2,376 GPD (per 15A NCAC 02T .01 l4) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this Iine ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04- l 6 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 6 57 Ductile Iron ➢ Section 11 &III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VII1. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC(Pump Stations/Force Mains),: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A N AC 02T .0 OS h 1 ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(l)(B); ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timefiames, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS -- (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0 05 ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall hp nrnw;rtPri fnr [a,uar eyeto— ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains(horizontal) 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines(horizontal - reclaimed over sewer 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NtvAC 02T.0305(s;} contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications web aue ➢ If noncompliance with 02T.0305(f)2g= see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) [:]Yes [:]No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® NIA ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer PermittinZ Branch 5. Does project comply with 15A NCAC 02T.0105(c)(61(additional permits/certifications)? ®Yes [:]No Per 1 c A NCAC 02T,0105(!* , directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes ®No ❑N`A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location) High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per I5A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with ISA NCAC 02T, the Minim m,_Dcsign_f.ri is o_r.the Fcrmi1Eing of PNEn tilt ! 5 imd Furcc_Mains.flatest version), and the Gravity Sewer Minimum Design Criteria LIatcst version as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required Prior to submittal of the Fast Tracts Application and supporting documents. 2. Professii Engineer's Certification: h - r * attest that this application for (Professional Engin er's name from Application Item I11.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 11 R 'SAL r. i 036242 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, David B Haskins Member/Manager attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: (23 Date: 9/22/2020 FORM: FTA 04-16 Page 5 of 5 NC Dept ofEnvironmcntal Qus►lit OCT 2 7 2020 State of North Carolina 1� Re(ionLll�. Department of Environmental Quality Dw RRalciDivision of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: SGWASA Project Name for which flow is being requested: Owen's Ride Subdivision More than one ME may be "ubvd for a sfngk project if the owner of the WWTP is not rmponsfble for au pump stations along the route of thepmposed wastewater floras I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: SGWASA WWTP b. WWTP Facility Permit #: NCO026824 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility AUfI'ows are in MGD 5.5 1.117 1.93 0.002376 3.049 h. Percent of permitted flow used 55.4% H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (13) (C) (1)r(B+C) (E)-(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow" Current Tributary Flow Plus (Name or Permit Capacity, • (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Ruitan PS 0.046 0.018 0.002 0.002 0.004 0.016 Stem Main PS OA67 0.187 0.043 0.002 0.045 0.144 Mangum Farms 1 PS 1.094 0.313 0.047 0.062 0.109 0.204 * The Firm Capacity (design flow) of any pump station Is defined as the masimunt pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(Ax4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity Is a 0. Downstream Facility Name (Sewer): SGWASA WWTP Downstream Permit Number: NCO026824 Page 1 of 6 FTSE 10-18 MLEGS UA O"ASITMINT OF TN! OftWM U.& CtOLocrAL UPromy 0 US bpo "ft CAMORAWAt 7-114-all Iwo lot '0 No l0000000 0 *Mod f;a to it KAL11.24M eY not � } < � - ■` 0 � 0 % 3 & 2 / n 3 ¥ O }G =a G o k k . ' ƒ 0 ~®!% � 3 @� J / o ] � � > �. 0 � � | % \ �. LIMITED LIABILITY COMPANY ANNUAL REPORT ■ 10l20r7 NAME OF LIMITED LIABILITY COMPANY: DLH Development, LLC SECRETARY OF STATE ID NUMBER: 1736104 STATE OF FORMATION: NC REPORT FOR THE CALENDAR YEAR: 2019 �■ ■0 SECTION A: REGISTERED AGENTS INFORMATION 1. NAME OF REGISTERED AGENT: David B Haskins 2. SIGNATURE OF THE NEW REGISTERED AGENT: SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT 3. REGISTERED AGENT OFFICE STREET ADDRESS & COUNTY 4. REGISTERED AGENT OFFICE MAILING ADDRESS 3605 Hwy 96 _ 3605 Hwy 96 Oxford, NC 27565 Granville Oxford, NC 27565 Granville SECTION H: PRINCIPAL OFFICE INFORMATION 1. DESCRIPTION OF NATURE OF BUSINESS: Real Estate Investment 2. PRINCIPAL OFFICE PHONE NUMBER: (919) 691-3714 3. PRINCIPAL OFFICE EMAIL: 4. PRINCIPAL OFFICE STREET ADDRESS S. PRINCIPAL OFFICE MAILING ADDRESS @' 3605 Hwy 96 - 3605 Hwy 96 9N. Oxford, NC 27565 Granville Oxford, NC 27565 Granville 6. Select one of the following if applicable. (Optional see Instructions) ❑ The company is a veteran -owned small business ❑ The company is a service -disabled veteran -owned small business SECTION C: COMPANY OFFICIALS (Enter additional company officials in Section E.) NAME: David B Haskins TITLE: Member ADDRESS: NAME: Trabar Homes, LLC TITLE: Managing Member ADDRESS: 3605 Hwy 96 3605 Hwy 96 Oxford, NC 27565 Granville Oxford, NC 27565 Granville ^ NC Dept of F.nvironmel'U'll QUaltit OCT 7 7 2020 NAME: Ralcigh Regional OITICIL TITLE: ADDRESS: SECTION D: CERTIFICATION OF ANNUAL REPORT. Section D must be completed in its entirely by a person/business entity. SIGNATURE DATE Form must be signed by a Company Official listed under Section C of This form. Print at Type Name of Company Official Print or Type Title of Company Official SUBMIT THIS ANNUAL REPORT WITH THE REQUIRED FILING FEE OF $200 MAIL TO: Secretary of State, Business Registration Divlslan, Post Office Box 29525. Raleigh, NC 2762"525 NCDE�IR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Dee Freeman Governor Drector Secretary January 4`h, 2012 Lindsay L. Mize, P.E., Executive Director South Granville Water and Sewer Authority NC Be Pt Central Avenue pt OfEnvironmentaI Qtp,ll�ti Suite B Butner, NC 27509 OCT 2 7 2020 Subject: South Granville Water and Sewer Authority Ralcibh Rc t Residential FIow Reduction Request ontt! Ottice Granville County Dear Mr. Mize: On October 7th, 2011, the Pretreatment, Emergency Response and Collection Systems (PERCS) Unit received a flow reduction request for future residential connections to the South Granville Water and Sewer Authority (SGWASA) sewage collection system. This adjustment would apply to all of SGWASA's permitted bul not yet tributary residential connections and all future residential connections tributary to the SGWASA collection system. Based upon the analysis submitted and a previous study conducted for the City of Creedmoor's collection system, the Division of Water Quality (Division) hereby approves an adjusted daily sewage design flow rate of 88 gallons per day per bedroom effective immediately, to be applied as follows: A) For existing permits with flow not yet tributary to the SGWASA collection system: 1) The Division will not reissue permits for previously permitted projects. If reissued permits are desired, a permit modification application with the appropriate fee must be submitted for each permit to be modified. , B) For new sewer extension applications with proposed flows tributary to the SGWASA collection system: 1) The flow reduction is applicable to residential single family dwellings only 2) The minimum flow for 1 and 2 bedroom dwellings shall be 176 gallons per day 3) This flow reduction shall not apply for sewer extension applications and/or permits for any other public or private organizations whose wastewater flows are or might become tributary to the SGWASA collection system. 107 Mill Service Center, Re -'soh, North Caroline 27699.1617 Loatlon 512 N Se6sbury SI Ralooh, North Carolina 27604 Phone 919407-83001FAX-91940744921Customer Se(vW-1.877-623.6748 Internet: w".nc*alemua6.oro An Eqwl opportunity t Aran&*@ At'tipn Empiarer �ac Karoii na )UMM1111 F' a. DESIGN & ENGINEERING, PLLC CLIENT -FOCUSED - COMPREHENSIVE - COST-EFFECTIVE October 20, 2020 NCDEQ— Raleigh Regional Office Attn: Water Quality Section 1628 Mail Service Center Raleigh, NC 27699 919-791-4200 2597 E. LYON STATION RD, STE 102 PO BOX ief CREEDNOOR, NC 27522 9f"j"99B lVC11%of En ent� Orr f uairi. RE: 1$-070 Owen's Ridge Subdivision — 207 Old NC 75, Stem, NC 275$1 ,r Fast Track Sewer Extension Submittal #1 rhe Enclosed are the following documents: QTY DESCRIPTION REC'D BY 1 ACTION RE 'D or (21 FYI ONLY 2 1- A - Application (1) 1 2 - 3 — Cover Letter (2) 1 3 - C— Application Fee (2) 1 4 - D — Proof of Registered Business (2) 1 5 - E - FTSE & Flow Reduction Letter (2) 1 6 - F — Site Maps (USGS Topo Map, Aerial Map) (2) 1 7 - J — Operational Agreement (2) 1 8 - Utility and Plan & Profile Plans (1) ACTION RE 'D: (1) Review and approve Please do not hesitate to contact us should you have any questions or comments regarding the contents. Regards, zb-�dq Allison AvereTe C3 Design & Engineering, PLLC allison@C3designeng.com J.\cabbott\DD-PROJECTS\2018118-070\CIVIL-18-070\Submittais12020-xx-xx DWR - Fast Track Sewer Extension\Doc\2020-09-22 Transmittai.docx