HomeMy WebLinkAboutWI0300224_Injection Event Record_20131216-1 a
ARCADIS
Infrastructure Water Environment Buildings
Attn: Ms. Sherri Knight
C/O: Mr. Michael Rogers
NCDENR — Division of Water Quality
Aquifer Protection Section — UIC Program
1636 Mail Service Center
Raleigh, NC 27699-1636
Subject:
Injection Performance Record
Former ExxonMobil Facility #40563
6530 Fairview Road
Charlotte, Mecklenburg County, NC
Incident Number: 9122
Dear Ms. Knight:
RECEIVED/DENR/M
DEC 16 2013
Water Quality Regional
Operations Section
On behalf of ExxonMobil Environmental Services (EMES), ARCADIS G&M of North
Carolina, Inc. (ARCADIS) is submitting an Injection Performance Record to the North
Carolina Department of Environment and Natural Resources (NCDENR) Division of
Water Quality — Aquifer Protection Section Underground Injection Control (UIC) Program
for former ExxonMobil facility #40563 located in Charlotte, Mecklenburg County,
North Carolina.
ARCADIS submitted a Notification of Intent to Construct or Operate Injection Wells
for review and approval on February 25, 2013 for the injection of sodium persulfate
utilizing ferrous sulfate heptahydrate and citric acid as activators at injection well
locations IW-1 and IW-2.
On the evenings of December 9 — 12, 2013 ARCADIS personnel completed a sodium
persulfate injection utilizing ferrous iron and citric acid as activators as follows:
• Approximately 328 gallons of the sodium persulfate and 328 gallons of the
ferrous sulfate heptahydrate/citric acid mixture was injected into injection well
IW-1.
Imagine the result
ARCADIS G&M of North Carolina,
Inc.
801 Corporate Center Drive
Suite 300
Raleigh
North Carolina 27607
Tel 919 854 1282
Fax 919 854 5448
www.arcadis-us.com
Environment
Date:
December 13, 2013
Contact:
Scott Bostian
Phone:
919.415.2291
Email:
Scott. Bostian@arcadis-
us.com
Our ref:
60085851.0024
ARCADIS G&M of North Carolina,
Inc.
NC Engineering License # C-1869
NC Surveying License # C-1869
�1
ARCADIS Ms. Sherri Knight
Mr. Michael Rogers .
December 13, 2013
• Approximately 328 gallons of the sodium persulfate and .328 gallons of the
ferrous sulfate heptahydrate/citric acid mixture was injected into injection well
IW-2.
In total, approximately 1,312. gallons of the sodium persulfate and ferrous sulfate
heptahydrate/citric acid mixture was injected at .the site on the evenings of December
9 — 1.2, 2013. An injection event record is:included as Appendix A.
A. RCADIS, will conduct two monthly post -injection groundwater monitoring and
sampling events in January 2014 and February 2014 as specified in the approved
Notification of Intent to Constructor Operate Injection Wells dated February 25,
2013..A report detailing the findings of the January 2014 and February 2014
groundwater monitoring and sampling events will be submitted to both the NCDENR
Division of Water Quality — Aquifer Protection UIC Program and the NCDENR
Division of Waste Management —'Underground Storage Tank (UST) Section for
review and, approval within 45 days.of.receipt of the February 2014 groundwater
laboratory analytical report.
Sincerely,
ARCADIS G&M of North Carolina, .Inc.
��9999088$®
0
Scott Bost%m�J►, Jon Farley, P.E.
P9
Senior En�A��°�oa� Certified Project Manager I
`Wan, 304
Appendix A:- Injection Event Record December 2 —_ 5, 20.13
Copies:
Ms. Jewel Cox — EMES
Mr..Dan Bowser— NCDENR UST Section -Mooresville .Regional Office
File.— EM 40563
Page:
2/2
. to
RECEIVED/DENR/M
DEC 16 2013
INJECTION EVENT RECORD Water Quality Regional
Operations Section
North Carolina Department of Environment and Natural Resources — Division of Water Quality
Permit Number permitted by Rule
1. Permit Information
ExxonMobil Corporation
Permittee
Former ExxonMobil Retail Facility #40563
Facility Name
6530 Fairview Road, Charlotte, North Carolina
Facility Address
2. Injection Contractor Information
ARCADIS G&M of North Carolina, Inc.
Injection Contractor / Company Name
Street Address 801 Corporate Center Dr. #300
Raleigh NC 27607
City State Zip Code
919 854-1282
Area code — Phone number
3. Well Information
Number of wells used for injection 2
Well names Iw-1 and IW-2
Were any new wells installed during this injection
event?
❑ Yes ❑x No
If yes, please provide the following information:
Number of Monitoring Wells
Number of Injection Wells
Type of Well Installed (Check applicable type):
❑ Bored ❑ Drilled ❑ Direct -Push
❑ Hand -Augured ❑ Other (specify)
Please include two copies of form GW-1 b for each
well installed.
Were any wells abandoned during this injection
event?
❑ Yes x❑ No
If yes, please provide the following information:
Number of Monitoring Wells
Number of Injection Wells,
Please include two copies of the GW-30 for each
well abandoned.
4. Injectant Information
Sodium Persulfate and Ferrous Sulfate / Citric Acid
Injectant Type
Sodium Persulfate (95%) - 50 g/L
Concentration Ferrous Sulfate / Citric Acid (5%) - 2.5 g/L
If the injectant is diluted please indicate the source
dilution fluid. Municipal water (City of Charlotte)
Total Volume Injected 1, 312-gallons
Volume Injected per well 656-gallons
5. Injection History
Injection date(s) December 9 - 12, 2013
Injection number (e.g. 3 of 5) 1 of 2 (estimated)
Is this the last injection at this site?
❑ Yes x❑ No
I DO HEREBY CERTIFY THAT ALL THE
INFORMATION ON THI���FEVI�� CORRECT TO
THE BEST OF MY K THAT THE
INJECTION WAS :# ,*1* AKIN THE
STANDARDS LAIDbl THE P�:
/6
c� C;2 fs
f3
SIGNATURE OF INJEC-9 O TRACTOR c DATE
Keith Carr & Salina
PRINT NAME OF PERSON
INJECTION
Submit the original of this form to the Division of Water Quality within 30 days of injection. Form UIC-IER
Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-733-3221 Rev. 07/09