Loading...
HomeMy WebLinkAboutWI0300224_Injection Event Record_20131216-1 a ARCADIS Infrastructure Water Environment Buildings Attn: Ms. Sherri Knight C/O: Mr. Michael Rogers NCDENR — Division of Water Quality Aquifer Protection Section — UIC Program 1636 Mail Service Center Raleigh, NC 27699-1636 Subject: Injection Performance Record Former ExxonMobil Facility #40563 6530 Fairview Road Charlotte, Mecklenburg County, NC Incident Number: 9122 Dear Ms. Knight: RECEIVED/DENR/M DEC 16 2013 Water Quality Regional Operations Section On behalf of ExxonMobil Environmental Services (EMES), ARCADIS G&M of North Carolina, Inc. (ARCADIS) is submitting an Injection Performance Record to the North Carolina Department of Environment and Natural Resources (NCDENR) Division of Water Quality — Aquifer Protection Section Underground Injection Control (UIC) Program for former ExxonMobil facility #40563 located in Charlotte, Mecklenburg County, North Carolina. ARCADIS submitted a Notification of Intent to Construct or Operate Injection Wells for review and approval on February 25, 2013 for the injection of sodium persulfate utilizing ferrous sulfate heptahydrate and citric acid as activators at injection well locations IW-1 and IW-2. On the evenings of December 9 — 12, 2013 ARCADIS personnel completed a sodium persulfate injection utilizing ferrous iron and citric acid as activators as follows: • Approximately 328 gallons of the sodium persulfate and 328 gallons of the ferrous sulfate heptahydrate/citric acid mixture was injected into injection well IW-1. Imagine the result ARCADIS G&M of North Carolina, Inc. 801 Corporate Center Drive Suite 300 Raleigh North Carolina 27607 Tel 919 854 1282 Fax 919 854 5448 www.arcadis-us.com Environment Date: December 13, 2013 Contact: Scott Bostian Phone: 919.415.2291 Email: Scott. Bostian@arcadis- us.com Our ref: 60085851.0024 ARCADIS G&M of North Carolina, Inc. NC Engineering License # C-1869 NC Surveying License # C-1869 �1 ARCADIS Ms. Sherri Knight Mr. Michael Rogers . December 13, 2013 • Approximately 328 gallons of the sodium persulfate and .328 gallons of the ferrous sulfate heptahydrate/citric acid mixture was injected into injection well IW-2. In total, approximately 1,312. gallons of the sodium persulfate and ferrous sulfate heptahydrate/citric acid mixture was injected at .the site on the evenings of December 9 — 1.2, 2013. An injection event record is:included as Appendix A. A. RCADIS, will conduct two monthly post -injection groundwater monitoring and sampling events in January 2014 and February 2014 as specified in the approved Notification of Intent to Constructor Operate Injection Wells dated February 25, 2013..A report detailing the findings of the January 2014 and February 2014 groundwater monitoring and sampling events will be submitted to both the NCDENR Division of Water Quality — Aquifer Protection UIC Program and the NCDENR Division of Waste Management —'Underground Storage Tank (UST) Section for review and, approval within 45 days.of.receipt of the February 2014 groundwater laboratory analytical report. Sincerely, ARCADIS G&M of North Carolina, .Inc. ��9999088$® 0 Scott Bost%m�J►, Jon Farley, P.E. P9 Senior En�A��°�oa� Certified Project Manager I `Wan, 304 Appendix A:- Injection Event Record December 2 —_ 5, 20.13 Copies: Ms. Jewel Cox — EMES Mr..Dan Bowser— NCDENR UST Section -Mooresville .Regional Office File.— EM 40563 Page: 2/2 . to RECEIVED/DENR/M DEC 16 2013 INJECTION EVENT RECORD Water Quality Regional Operations Section North Carolina Department of Environment and Natural Resources — Division of Water Quality Permit Number permitted by Rule 1. Permit Information ExxonMobil Corporation Permittee Former ExxonMobil Retail Facility #40563 Facility Name 6530 Fairview Road, Charlotte, North Carolina Facility Address 2. Injection Contractor Information ARCADIS G&M of North Carolina, Inc. Injection Contractor / Company Name Street Address 801 Corporate Center Dr. #300 Raleigh NC 27607 City State Zip Code 919 854-1282 Area code — Phone number 3. Well Information Number of wells used for injection 2 Well names Iw-1 and IW-2 Were any new wells installed during this injection event? ❑ Yes ❑x No If yes, please provide the following information: Number of Monitoring Wells Number of Injection Wells Type of Well Installed (Check applicable type): ❑ Bored ❑ Drilled ❑ Direct -Push ❑ Hand -Augured ❑ Other (specify) Please include two copies of form GW-1 b for each well installed. Were any wells abandoned during this injection event? ❑ Yes x❑ No If yes, please provide the following information: Number of Monitoring Wells Number of Injection Wells, Please include two copies of the GW-30 for each well abandoned. 4. Injectant Information Sodium Persulfate and Ferrous Sulfate / Citric Acid Injectant Type Sodium Persulfate (95%) - 50 g/L Concentration Ferrous Sulfate / Citric Acid (5%) - 2.5 g/L If the injectant is diluted please indicate the source dilution fluid. Municipal water (City of Charlotte) Total Volume Injected 1, 312-gallons Volume Injected per well 656-gallons 5. Injection History Injection date(s) December 9 - 12, 2013 Injection number (e.g. 3 of 5) 1 of 2 (estimated) Is this the last injection at this site? ❑ Yes x❑ No I DO HEREBY CERTIFY THAT ALL THE INFORMATION ON THI���FEVI�� CORRECT TO THE BEST OF MY K THAT THE INJECTION WAS :# ,*1* AKIN THE STANDARDS LAIDbl THE P�: /6 c� C;2 fs f3 SIGNATURE OF INJEC-9 O TRACTOR c DATE Keith Carr & Salina PRINT NAME OF PERSON INJECTION Submit the original of this form to the Division of Water Quality within 30 days of injection. Form UIC-IER Attn: UIC Program, 1636 Mail Service Center, Raleigh, NC 27699-1636, Phone No. 919-733-3221 Rev. 07/09