WQ0039488_Monitoring - 09-2020_20201014
FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page 4 of `1 Permit No.: WQ0039488 Facility Name: Courthouse Area WWTP County: Camden Month: September Year: 2020 PPI: 001 Flow Measuring Point: ❑ influent E Effluent ❑ No Flow generated Parameter Monitoring Point: ❑ Influent Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code 0 50050 00310 00940 31616 00610 00625 00620 00600 00400 00665 70300 00530 p > d U F- O C E N ~ O N O m d "O s U E V p ti o U � C O £ q L 70 C N d � Y o o Z y0,, �9 Z C d N m Z = N 2 p t6 L I- o r a 9 O N R 'O F- N 0 N � cn t9 C 'D N N Cn 24-hr hrs GPD mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L 1 07:00 1 20,499 7.1 2 07:00 1 21,721 3.3 < 1 0.06 1.07 7.91 9.06 7.09 0.46 < 2.5 3 07:00 1 24,228 6.9 4 07:40 1 19,739 7.06 5 19,738 6 19,739 7 19,739 8 07:00 1 24,117 7.3 9 0710 1 25,342 6.9 10 07:15 1 24,017 7.11 11 07:00 1 23,252 7.01 12 23,252 131 23,252 14 07:15 1 24,570 6.9 15 07:00 1 27,828 7 16 07:15 1 26,906 < 2.0 < 1 0.18 1.06 7.92 9.66 7.4 0.6 < 2.5 17 06:50 1 30,878 6.9 18 07:00 1 24,445 6.9 19 24,445 20 24,445 21 0700 1 28,877 7 22 07:25 1 26,452 7 23 07:30 1 26,720 6.9 24 07.35 1 24,639 6,9 25 07.10 1 18,380 6.9 26 18,380 27 18,379 28 07:20 1 38,450 6.9 29 07:35 1 25,725 6.9 30 07:34 1 24,810 6.9 31 Average: 24,099 1.65 1.00 0.12 1.07 7.92 9.36 0.53 0.00 Daily Maximum: 38,450 3.30 1.00 0.18 1.07 7,92 9.66 7,40 0.60 2.50 Daily Minimum: 18,379 2.00 1.00 0.06 1.06 7.91 9.06 6.90 0.46 2.50 Sampling Type: Recorder Composite Composite Grab Composite Composite Composite Composite Grab Composite Composite Composite Monthly Limit: 99,890 10 14 4 10 4 2 15 Daily Limit: Sample Frequency: Continuous 2 X Month 3 X Year 2 X Month 2 X Month 2 X Month 2 X Month 2 X Month 5 X Week 2 X Month 3 X Year 2 X Month FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page = of � Permit No.: W00039488 Facility Name: Courthouse Area WWTP County: Camden Month: September Year: 2020 PPI: 002 Flow Measuring Point: ❑ Influent 0 Effluent Ell No Flow generated Parameter Monitoring Point: ❑ Influent ❑✓ Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code 0 50050 00310 00940 31616 00610 00625 00620 00600 00400 00665 70300 00530 O c O E Q ° O ° U ° ° ai °= LL U o E ¢ r m rnc Y 2 0 c o Z in ° °- N ° a —o'a= m ° O in o° N 24-hr hrs GPD mg/L mg/L #/100 mL mg/L mg/L I mg/L mg/L su mg/L mg/L mg/L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Average: #DIV/0! Daily Maximum: 0 Daily Minimum: 0 Sampling Type: Recorder Composite Composite Grab Composite Composite Composite Composite Grab Composite Composite Composite Monthly Limit: 99,890 10 14 4 J 10 4 2 15 Daily Limit: Sample Frequency: Continuous 2 X Month 3 X Year 2 X Month 2 X Month 1 2 X Month 2 X Month 2 X Month 5 X Week 2 X Month 3 X Year 2 X Month FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: W00039488 Facility Name: Courthouse Area WWTP County: Camden Month: September Year: 2020 PPI: 003 Flow Measuring Point: ❑ Influent ❑� Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent ❑ Effluent ❑ Groundwater Lowering ❑ Surface water Parameter Code 0 50050 00940 31616 00610 00620 00400 00665 70300 CU 0 E ¢ m U O C 0 y F m ~U W O 3 o LL m LL O U £ Q R ao V) O s a O d a)N a)a o yo o U) n 6 24-hr hrs GPD mg/L #/100 mL mg/L mg/L su mg/L mg/L 1 07:00 1 34,752 2 0700 1 20,566 102 1 0.75 3.51 7.09 0.3 435 3 07:00 1 11,758 4 07:00 1 36,094 5 36,094 6 36,094 7 36,095 8 07:00 1 21,554 9 07:00 1 22,175 10 0700 1 24,393 11 0700 1 22,050 121 22,050 13 22,050 14 07:00 1 20,033 15 07:00 1 20,674 16 0700 1 21,923 17 0700 1 4,928 18 07:00 1 42,807 19 42,807 20 42,808 21 07:00 1 30,812 22 0700 1 29,293 23 07:00 1 27,193 24 07:00 1 25,687 25 07:00 1 23,363 26 23,363 27 23,364 28 07:00 1 24,440 29 07:00 1 28,495 30 07:00 1 30,685 31 Average: 26,947 102.00 1.00 0.75 3.51 0.30 435.00 Daily Maximum: 42,808 102.00 1.00 0.75 3.51 7.09 0.30 435.00 Daily Minimum: 4,928 102.00 1.00 0.75 3.51 7.09 0.30 435.00 Sampling Type: Recorder Grab Grab Grab Grab Grab Grab Grab Monthly Limit: Daily Limit: 130,000 250 1.5 10 6.5-8.5 500 Sample Frequency: Continuous Monthly Monthly Monthly Monthly Monthly Monthly Monthly FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page LA of q_ Sampling Person(s) Certified Laboratories Name: David A. Credle Name: Environment 1, Inc. Name: Jovon Taylor Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant El Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. 1:001 Overlimit on Total N Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: David A. Credle Permittee: Camden County Certification No.: 994351 Signing Official: David A. Credle Grade: 3 Phone Number: 252-207-6874 Signing Officials Title: Public Works Manager Has the ORC changed since the previous NDMR? ❑ Yes No Phone Number: 252-207-6874 Permit Expiration: 1/31/2023 -AL� (o / -r / i o 1 "r / zo Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page Permit No.: WQ0039488 Facility Name: Courthouse Area WWTP County: Camden Month: SepteMber • infiltration occur - �� t ■�-_ this facility? Area (acres): pYES NO •• ©�Rate •. •• e-• •... p�� ■ • ■ ■ • ■�. �i ■ ■ • 0 omo mmUMMMMM �� • • ���� ���� ���� Mmm0MM ��®� ���� ���■� ���� mmmomm ��� m om®mm MM� m mmm mm Monthly Loading (GPD/ Year to Date Loading in-D-filf+2�. FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page �-- of 2— Did the application rates exceed the limits in Attachment B of your permit? E Compliant ❑ Non -Compliant If not a basin, were the sites kept free of vegetation and raked? '❑ Compliant ❑ Non -Compliant If not a basin, were there any instances of effluent ponding in or runoff from the sites? 0 Compliant ❑ Non -Compliant If a basin, were there any instances of breakout from the berms? El Compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? El Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification I Permittee Certification I I ORC: David A. Credle I Certification No.: 994351 Grade: 3 Phone Number: 252-207-6874 Has the ORC changed since the previous NDAR-27 ❑ Yes F±1 No _ZM4_a_X C�L� tohl w Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. Permittee: Camden County Signing Official: David A. Credle Signing Officials Title: Public Works Manager Phone Number: 252-207-6874 Permit Exp.: 1/31/23 Signature Date I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617