Loading...
HomeMy WebLinkAbout20201765 Ver 1_Meeting Request Review_20201117ID#* 20201765 Version* 1 Regional Office* Central Office - (919) 707-9000 Reviewer List* Rick Trone Pre -Filing Meeting Request submitted 11/17/2020 Contact Name * Contact Email Address* Project Name* Project Owner* Project County* Owner Address: Deborah Shirley dshirley@sandec.com Carolina Pines Shail Investors and Developers LLC (Attn: Manoj Jain) Wake Street Address 114 Tealight Lane Address Line 2 aty Cary Rbstal / Zip Code 27513 Is this a transportation project?* r Yes r No State / Frovince / Region NC Country USA Type(s) of approval sought from the DWR: W 401 Water Quality Certification - F 401 Water Quality Certification - Regular Express r- Individual Permit r- Modification r- Shoreline Stabilization Does this project have an existing project ID#?* r Yes r No Do you know the name of the staff member you would like to request a meeting with? Stephanie Goss Please give a brief project description below. The Carolina Pines project is a proposed multi -family residential development located at 2640 cherry circle & 511 carolina pines ave in Raleigh, NC. This project is located in the neuse river basin and is approximately 15.61 acres. There are proposed impacts to riparian buffers and perennial streams. Please give a couple of dates you are available for a meeting. 11 /18/2020 11 /19/2020 11 /20/2020 11 /23/2020 11 /24/2020 Please attach the documentation you would like to have the meeting about. cpines-reduced.pdf 1.22MB pdr only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature Submittal Date 11/17/2020 Reviewer Meeting Request Decision Has a meeting been scheduled?* r Yes r No UTILITY NOTES THE LOCAL JURISDICTIONAL REQUIREMENTS AND STANDARDS. 1. UNLESS OTHERWISE NOTED, ALL MANHOLES SHALL BE PRE -CAST 4. THE CONTRACTOR SHALL COORDINATE ALL PEDESTRIAN AND VEHICULAR 8. ELEVATIONS OF UTILITIES ARE GIVEN TO THE EXTENT OF INFORMATION 10. AS -BUILT DOCUMENTATION REQUIREMENTS: PRIOR TO APPROVAL FROM CONCRETE STRUCTURES. INTERRUPTIONS WITH OWNER'S REPRESENTATIVE AT LEAST 72 HOURS AVAILABLE, WHERE ELEVATIONS ARE NOT GIVEN AT POINTS OF EXISTING LOCAL JURISDICTION OR ENGINEER THE CONTRACTOR SHALL PROVIDE PRIOR TO BEGINNING WORK. 7. ALL EXISTING SUB -SURFACE UTILITIES IDENTIFIED ON THE CONSTRUCTION UTILITY CROSSINGS, SUCH ELEVATIONS SHALL BE DETERMINED BY THE AS -BUILT DRAWINGS (IN BOTH PAPER AND ELECTRONIC FORMAT (CAD / 2. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF DOCUMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON CONTRACTOR AND REPORTED TO THE ENGINEER, WHEN UNKNOWN LINES PDF) PREPARED AND SEALED BY A PROFESSIONAL LAND SURVEYOR UNDERGROUND UTILITIES (WATER, SEWER, STORM, ELECTRICAL, GAS, OR 5. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK INSIDE THE SURVEY INFORMATION GATHERED FROM FIELD INSPECTION AND/OR ANY ARE EXPOSED, THEIR LOCATIONS AND ELEVATIONS SHALL ALSO BE SHOWING ALL UTILITY INSTALLATION. HORIZONTAL AND VERTICAL OTHER) FOR THIS PROJECT WITH THE BUILDING PLANS. THE UTILITY PUBLIC RIGHT OF WAY PRIOR TO RECEIPT AND COMPLIANCE WITH ALL OTHER APPLICABLE RECORD DRAWINGS WHICH MAY BE AVAILABLE. DEPTHS REPORTED TO THE ENGINEER. INFORMATION SHALL BE PROVIDED FOR WATER, SEWER, STORM INCLUDING CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE INSTALLATION OF APPLICABLE NCDOT PERMITS. ADDITIONALLY, THE CONTRACTOR SHALL BE OF EXISTING UTILITIES SHOWN IN PROFILE VIEWS ARE BASED ON ALL STRUCTURES, VALVES, HYDRANTS, AND OTHER APPURTENANCES. ALL UTILITY SERVICES TO WITHIN FIVE (5) FEET OF THE BUILDING RESPONSIBLE FOR PROVIDING ALL NECESSARY FLAGGERS AND TRAFFIC STANDARD ASSUMPTIONS. THE CONTRACTOR SHALL FIELD VERIFY THE 9. UNDERGROUND UTILITIES SHOWN ON THIS PLAN SHALL BE INSTALLED CONNECTION POINT. CONTROL DURING ALL WORK INSIDE THE PUBLIC RIGHTS OF WAY. EXACT LOCATION, DEPTH, SIZE AND MATERIAL OF ANY AND ALL PRIOR TO ANY CONSTRUCTION OF PARKING AREA, DRIVES, CURB AND SUB -SURFACE CONDITIONS REFERENCED IN THESE PLANS PRIOR TO ANY GUTTER OR CONCRETE WALKS / PADS. IF UTILITIES SHOWN ON THIS 3. THE CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS ON SITE 6. THE CONTRACTOR SHALL NOT RE -USE ANY FIRE HYDRANT REMOVED AS EXCAVATION OR CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL PLAN CANNOT BE INSTALLED PRIOR TO INSTALLATION OF IMPERVIOUS AND UTILITY PROVIDERS DURING CONSTRUCTION TO ENSURE SMOOTH PART OF THIS PROJECT. ANY FIRE HYDRANT SHOWN TO BE REMOVED OR IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE OF ANY (ASPHALT / CONCRETE) CONDUIT SHALL BE INSTALLED FOR THE "FUTURE" RELOCATED SHALL BE REPLACED WITH A NEW FIRE HYDRANT MEETING DISCREPANCIES OR CONFLICTS UTILITY INSTALLATION D RYE i *a* �akaa kaw McGLAMERY, TRANSITION BETWEEN DISCIPLINES. o CPA ENGINEERING , PLLC N T S NrTE STREET MgRe�F PECAN ROAD NC FIRM LICENSE #P-1305 STREET ST � ��� INV: 273.53 CARDt r F FT NA P'NES w Cep? j AVENUE o; �o ��,� `ram cp c WOODEN PP BRIDG �� SITE ISSUED FOR ' INV:275.91' /�15 I •'36' ' 27 N REVIEW PP "d• "I�/ICINITY MAP NOT FOR INV:280.25' / RTW �� �' O O TIE TO AN EXISTING MANHOLE AT THE , / PP CONSTRUCTION � � INTERSECTION OF CAROLINA PINES AVENUE G TW �i,� SURVEY DISCLAIMER & SUFFOLK BOULEVARD —CNV:280.99' SIGN 'r SURVEY INFORMATION PREPARED BY L. \ INV: 283.40' ' r`` , JORDAN PARKER (PLS L-4665) ON FEBRUARY X, STAINLESS \ 8ESS STEEL FULL CIRCUMFERENCE TAPPING SLEEVE AND VALVE i �'RG / 'µ 2019. CAWTHORNE, MOSS, & PANCIERA, PC, INV:285.33 O GRAVEL , �5� ' % 333 S. WHITE STREET, WAKE FOREST, NC 27588 � � � � �. FENCE _ - C P INV:288.50' \7 — — — — _ _ — — INV:289.61' \� PP 5"R IGN INV:292.46' 2" CITY OF RALEIGH APPROVED - \� �� GRq I �, 5"R PINV:300.16' SIGN 1 "R P INV:293.71' METER AND METERBOX F� P" _ \ �- \ _ NV.30 .07 = INV: 297.08' - INV.296.33 F� - / l LEGEND �J �<v GN � . O _ _ T�L 0� \ QP BATTERY — —RPZ Fit P I Q% _ _ — — � BOXO � -- ❑ H ATE O E i SYMBOL DESCRIPTION F❑ — _r ITF W— EXISTING E R L I N E \ �c, F- ❑ \� ❑ •tiBL "QG "��---_........_...._..._.,..__..._....._..................._ R A BACKF 0 PREV TER IN �`. W PROPOSED WATER LINE O PP__..__,.._ ................_........_.._..-_............. ........_� I PROPOSED SANITARY SEWER LINE • 1 ' ss \ / Q �' - Xy PROPOSED FIRE HYDRANT L " J O / " / (&PROPOSED WATER VALVE � / _ ` C.o. OS EXISTING SANITARY SEWER MANHOLE S PROPOSED SANITARY SEWER MANHOLE �0 PROPOSED CLEANOUT / FDC PROPOSED FDC ' & PROPOSED BACKFLOW METER 6" C.O. y s 6.. CO. •t i' s y5 PIV PROPOSED POST INDICATOR VALVE (PIV) NORFOLK SOUTHERN •.;.• �' EXISTING MH— CORET C NECTION • GREASE INTERCEPTOR / RAILWAY 100' R/W / B.M. 1997, PAGE 526 / `. ®� — — — <•1 / 300' HYDRANT COVERAGE CIRCLE \_ / fffi LIMITS OF DISTURBANCE J / "•:�� s � 6" C.O. � 'o 6" C.O. •o Mj ►► ��eP NOTE: REFER TO N ILL W TRANSPORTATION PLAN C-2.1 FOR 0 co� J _ EXISTING STREET LLI 0 r J� Y N /.: AND RIGHT—OF—WAY E W 0 z° J z 0 DIMENSIONS _ x = z�W "w J LLJ 11:11�W�Ja� r1'ZOJ 20 BL S �......:...... - U cVi1 Z 0Wttti�_ 6" C.O. EXISTING MH 300 CD > ti CORE AND BOOT CONNECTION_ _ — _ I_ _ PROJECT NO 8031 I -T......... �.... ...................................._. •. ................ SWAMP.......................... ...................................... REVIEW I ............................ . / •" "" / � REV DESRIPTION DATE I / / CONCURRENT REVIEW APPROVAL CITY OF RALEIGH - PLANS ALITHORiZED FOR CONSTRUCTION N/F Plans for the proposed use have keen reuiewed for general compliance with WEST PARKLAND L I N C PARTNERS I / /' / z I a ppli cable codes_ This limited review, and authorization far construction is not to / / / / \ O be considered to represent total compliance with all legal requirements for D.B. 5002, PAGE 709 I // // N/F O r— development and construction. The property owner, design consultants, and PIN # 17 0 2.10 — 2 6 —10 8 5 / / WEST PARKLAND L I N C PARTNERS / -)3 z contractors are each responsible for compliance with all applicable City, State and \ / / D.B. 5002, PAGE 709 / / v \ rQ O 2 _ Federal laws. This specific authorization below is not a permit, nor shall it be Q y construed to permit any violation of -City, State or Federal Law, All Construction \ / / PIN # 1702.10— 2 6 — 336 2 ,� .� � '� �� ---I� ­4 I must be in accordance with all Local, State, and Federal flulesand Regulations. �� r TRANSPORTATION FIELD SERVICES DRAWN BY DJM �_ cS �� O -p I CHECKED BY HWD 'n \ G 1 PUBLIC UTILITIES C 77 O 13 � N O °O SCALE: 1" = 30 \�\ \ 7fn O yQ � O I I I S,C4RMVVATER O�O N'0 0 15 30 60 � 0) Gn PL4NNINGJZONINGo FIRE UTILITY PLAN WEST \ CP I URBAN FORESTRY / I SITE ACCESSIBILITY Cm6nOO UTILITY NOTES 1. UNLESS OTHERWISE NOTED, ALL MANHOLES SHALL BE PRE -CAST 4. THE CONTRACTOR SHALL COORDINATE ALL PEDESTRIAN AND VEHICULAR CONCRETE STRUCTURES. INTERRUPTIONS WITH OWNER'S REPRESENTATIVE AT LEAST 72 HOURS PRIOR TO BEGINNING WORK. 2. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF UNDERGROUND UTILITIES (WATER, SEWER, STORM, ELECTRICAL, GAS, OR 5. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK INSIDE THE OTHER) FOR THIS PROJECT WITH THE BUILDING PLANS. THE UTILITY PUBLIC RIGHT OF WAY PRIOR TO RECEIPT AND COMPLIANCE WITH ALL CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE INSTALLATION OF APPLICABLE NCDOT PERMITS. ADDITIONALLY, THE CONTRACTOR SHALL BE ALL UTILITY SERVICES TO WITHIN FIVE (5) FEET OF THE BUILDING RESPONSIBLE FOR PROVIDING ALL NECESSARY FLAGGERS AND TRAFFIC CONNECTION POINT. CONTROL DURING ALL WORK INSIDE THE PUBLIC RIGHTS OF WAY. 3. THE CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS ON SITE 6. THE CONTRACTOR SHALL NOT RE -USE ANY FIRE HYDRANT REMOVED AS AND UTILITY PROVIDERS DURING CONSTRUCTION TO ENSURE SMOOTH PART OF THIS PROJECT. ANY FIRE HYDRANT SHOWN TO BE REMOVED OR TRANSITION BETWEEN DISCIPLINES. RELOCATED SHALL BE REPLACED WITH A NEW FIRE HYDRANT MEETING EEL STREET -� �QV:261.60' 50' PUBLIC R INV: 261.87' 8"X8" TAPPING SLEEVE AND VALVE V:262.57' / STAINLESS STEEL FULL CIRCUMFERENCE Q� EXISTING MH-100 <0 CORE AND BOOT CONNECTION S , .INV: 263.59 Q IN 65.59' J I V: 266.51' P PP \ s SIGN INV:273.53k Q INV: 2.60' WOODEN PP / - FXI(:�TING fin' PRIVATE ems` THE LOCAL JURISDICTIONAL REQUIREMENTS AND STANDARDS. 8. ELEVATIONS OF UTILITIES ARE GIVEN TO THE EXTENT OF INFORMATION 10. AS -BUILT DOCUMENTATION REQUIREMENTS: PRIOR TO APPROVAL FROM AVAILABLE, WHERE ELEVATIONS ARE NOT GIVEN AT POINTS OF EXISTING LOCAL JURISDICTION OR ENGINEER THE CONTRACTOR SHALL PROVIDE ALL EXISTING SUB -SURFACE UTILITIES IDENTIFIED ON THE CONSTRUCTION UTILITY CROSSINGS, SUCH ELEVATIONS SHALL BE DETERMINED BY THE AS -BUILT DRAWINGS (IN BOTH PAPER AND ELECTRONIC FORMAT (CAD / DOCUMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON CONTRACTOR AND REPORTED TO THE ENGINEER, WHEN UNKNOWN LINES PDF) PREPARED AND SEALED BY A PROFESSIONAL LAND SURVEYOR SURVEY INFORMATION GATHERED FROM FIELD INSPECTION AND/OR ANY ARE EXPOSED, THEIR LOCATIONS AND ELEVATIONS SHALL ALSO BE SHOWING ALL UTILITY INSTALLATION. HORIZONTAL AND VERTICAL OTHER APPLICABLE RECORD DRAWINGS WHICH MAY BE AVAILABLE. DEPTHS REPORTED TO THE ENGINEER. INFORMATION SHALL BE PROVIDED FOR WATER, SEWER, STORM INCLUDING 6/ OF EXISTING UTILITIES SHOWN IN PROFILE VIEWS ARE BASED ON ALL STRUCTURES, VALVES, HYDRANTS, AND OTHER APPURTENANCES. STANDARD ASSUMPTIONS. THE CONTRACTOR SHALL FIELD VERIFY THE 9. UNDERGROUND UTILITIES SHOWN ON THIS PLAN SHALL BE INSTALLED 40 EXACT LOCATION, DEPTH, SIZE AND MATERIAL OF ANY AND ALL PRIOR TO ANY CONSTRUCTION OF PARKING AREA, DRIVES, CURB AND SUB -SURFACE CONDITIONS REFERENCED IN THESE PLANS PRIOR TO ANY GUTTER OR CONCRETE WALKS / PADS. IF UTILITIES SHOWN ON THIS EXCAVATION OR CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL PLAN CANNOT BE INSTALLED PRIOR TO INSTALLATION OF IMPERVIOUS IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE OF ANY (ASPHALT / CONCRETE) CONDUIT SHALL BE INSTALLED FOR THE "FUTURE" DISCREPANCIES OR CONFLICTS. UTILITY INSTALLATION. o GRANITE STREET PECAN ROAD MQRe`F STREET N/F / \ \ \ \ LEWIS DOWNEY CAROLINA A PINES E� T PRIVATE \\ \ -• I D.B. 9272, PAGE 1111 / �o�� VENUE DF� I SEMENT -- "F B.M. 1956, PAGE 61 N/F / SJJ�tJPO \ �L N/ WASHINGTON E. POLIT o ® B.M. 1 P GE 526 \ \ \ JUAN PABLO CONSTANZA PIN# 1702.10-36-4995 / D.B. 16172, PAGE 1192 e _1 D.B. 13694, PAGE 342 I B.M. 1956, PAGE 61 / SITE \ \ B.M. 1956, PAGE 61 PIN# 1702.10-36-5974 ED HYDRANT TYP \ \ / \ PIN# 1702.10-36-4913 / 6" TEE AND 6" VALVE T \ \` RAYMOND LEE AVERY JR. DIP HYDRANT LEG `' �` D.B. 4078, PAGE 631 / VICINITY MAP N.T.S. � �.. � \ B.M. 6 61 PIN1702.10 PAGE 36 3950 \ I \ / SANTOS ELIAS CONST D.BB:M126�56, PAGE AGE26 SURVEY DISCLAIMER PIN# 1702.10-36-6s \.......... N/F I / SURVEY INFORMATION PREPARED BY L. 2 CITY RA IGH APPROV JULIE WENTA •`',. RPZ B W PREVENTE I D.B. 12741, PAGE 893 / JORDAN PARKER (PLS L-4665) ON FEBRUARY X, \ EAT D ENCLOSUR ) B.M. 1956, PAGE 61 2019. CAWTHORNE, MOSS, & PANCIERA, PC, PIN# 1702.10-36-2867 / 333 S. WHITE STREET, WAKE FOREST, NC 27588 CHERRY CIRCLE \ 8" CITY OF RALEIGH APPROVED ; l 50 PUBLIC R/�V W RPnA RA(KFInw PRF\/FNTFR IN / D R Y E i *w *ak4�aakft McGLAMERY u V V. L/ J. J N \� I-- ��® I :275.36' PP /r' ` ` r INV:280.25' RTWAVE — r rGoY \ \ S ...t P P t � � SYMBOL DESCRIPTION / PP �. WIR \ \ \ \ , FLU TW \ \ B \ EXISTING WATER LINE TNV:280.99' N� r; I /�. \ .. =r N F \ W PROPOSED SIGN \ \ 1 D / EXISTING SANITARY SEWER LINE INV:283.40' • .-'•�"'. `_ '� CORTEZ HARRIS JR. TRUSTEE ,,.� \ \ c�•, 7' 6" C.O.! \ PROPOSED SANITARY SEWER LINE C CORTEZ HARRIS JR. REVOCABLE TRUST \ SS C, \ D.B. 16878, PAGE 546 PROPOSED FIRE HYDRANT PP �oN'r -1 -� �.., ::�.� TF �,�' B.M. 1956, PAGE 61 yv `��` �0 1 \SEE AND ��)y PIN# 1702.10-36-4784 ® PROPOSED WATER VALVE IGN R` VI.R / / `\ •� `O 1 O 6� .4 ��- I-/%c \ . 1 OS EXISTING S NG SANITARY SEWER MANHOLE F0 ,,79�j� A�•Q 2" CITY OF RALEIGH APPROVED O PROPOSED SANITARY SEWER MANHOLE R IN /4) D�S6 ED-ENC OS R 0 : TR T •� A /� RPZ BACKFLOW�P—REV�TE i `� HEAT L U E(TYP) � PROPOSED CLE NOU wr..s r NG aRK� ,;;•,. E PROPOSED FDC P / / / ' ".. 6`Aj � Tp� FDC Go. ,, ��� _ .. 00 ST. N/F PROPOSED BACKFLOW METER SARAH LE s" C.O. 1•,.: . D.B. 15820, PAGE 2747 PIS/ C / \ ' • • t PROPOSED POST INDICATOR VALVE ( I ) 8"X6" TEE AND 6' VALVE ............. � PIN 1 .610 _ 06 6" DIP HYDRANT LE-' # 70 36 56 O GREASE INTERCEPTOR B.M.195 PAGE 61 � r; STRUC - 3 ",%'` 8" CITY OF RALEIGH APPROVED 300' HYDRANT COVERAGE CIRCLE RPDA BACKFLOW PREVENTER IN / \ \ 1-7` — PROPOSED HYDRANT (T ,,,- HEATED ENCLOSUR TYP LIMITS OF DISTURBANCE N LUISGAITAN / ANCA R. GA TAN CORE ND BO CONNECTION EXISTING 20 / / ! N y III 7 • ' D.B. 7904, PAGE 790 B.M. 1956, PAGE 61 1 s:• : ,•' PIN# 1702.10-36-4599 r J �: II 476,110 sq. f t. _ r N/F 10.930 AC. 1g TURNER LEON BROWN I 20.00' CITY OF RALEIGH WATERLINE EASEMENT 2`4� a `� S RU O _ ' D.B. 6161, PAGE 290 , B NOTE: REFER TO ...................^y..................... i , , 1956 PAGE 61 o PIN # 1702.10-36-4592 TRANSPORTATION 'i� s �"�S=�i ;6` C.O. s 1 J I PLAN C-2.1 FOR s � "X2" TEE AND VALVES - ,Y EXISTING STREET WALL MOUNTED FDC ' G� —6'�P FIRELINE yam' s .'• s 6"DIP HYDRANT LEG I N/F AND RIGIAT—OF—WAY t' TRUSTEE OF THE CHERRY 2607 TRUST WITH HA s" C.O. 6„ s s' Ss CITY ED D.B. 16338, PAGE 986 METER AND METERB X Y DIMENSIONS S s 8"X8"ETEE AND VALVE I PIN# 1702 610 PAGE T P C TY OF RA EI H PPROVED Z EJ s" C.O. r y' 6" C.O. ! - = 8"X2" TEE AND VALVES I N/F SAUNDRA ELAINE MATTHEWS ,'.. }• ? .' s :. •.... ;..... ' .. i : ? i 6" C.O. D.B. 296 PAGE 213 ;. D 8" CITY OF RALEIGH APPROVED I s 2" CITY OF RALEIGH APPROVE J - _, .:... "., B.M.BM1956, PAGE 61 RPDA BACKFLOW PREVENTER IN 6 :� METER AND METERBOX (TYP)PI 170210 36 5401 HEATED ENCLOSURE(TYP) _ o tlLUG S6�3' PAR KING SB ._..... __ ....................... .......... ................. I — — _____________-_----___-----_-_-----____RKING SB - 1 _ _An ENGINEERING, PLLC INC FIRM LICENSE #P-1305 ISSUED FOR REVIEW NOT FOR CONSTRUCTION 12 10 0 E } J M � N U H H J W � U) � J �CCDQ Z U �JXCCD 0-Y Z z N X - N < X z� z O Z O ILr LL zaW=6(a) 0 2 UWx= 2t W , 0Uj W2 O W W Y H aLU Z(nCD W- � W �zCJ a UoNx5Z ti 0LUMx PROJECT NO: 2018031 REVIEW REV I DESRIPTION I DATE A ISSUED FOR REVIEW 108.11.2020 CONCURRENT REVIEW APPROVAL _ _ _--............ - 6 8L RKING SB - \ ........... �W 0 OS� O - I CITY OF RALEIGH PLAh15AUTHORIZEa FOR COIdSTRUCTICrN -____ _.. Z - I ; � zWW I _ _ z co D ��tADG� O - - - - - - -................_................. _ 00 Z_ DALILA ALDANA o� v ------ D �,W� I ���'��" D.B. 8691, PAGE 1818 p I -0 p — — — — — — o (0 N �a O O W O � � !0 Plans for the proposed use have been reviewed for general compliance with o I z------- !��o 0(0 NO00;)0 I PIN# 1702,10-36-5313 p �o Z rA ' O - - - 1^: 14 O) O Z Z N 0-) � D Z �. O O applicable codes. This limited review, and authorliation for -construction Is not to 2� p rn I Z Q1 D p r I �10' DRAINAGE C O+ \ I O- �� O O tJ1 A be considered t represent total compliance with all legal requirements for _rnZ � U) ° �o v oc= EASEMENT I 0, Z I o (D � ➢ = I z M. 1968 PG. 31 N/F 1- RA E a) C) 0 n c,•I y I owe m development and construction. The property rnrmer, design consultants, and \ rJ �'/� N OF) O r- Z J m !Tr r I O r, I r rn � ;U I contractors are each responsible for compliance with all applicable City, state and o 3 W' o cD rn o rn Z I c� LEWIS H DOWNEY \ I I,, I I r� —I 1 y tS 2 T -0 -n N J r Z rl I: _ J CP —k O r^ C, w Federal laws. This specific authorization below is not a permit, nor shall it be �Cs'`s G 0+_10 �cA- o� 0LO(D ��v, N/F & ANNE S. DOWNEY _�7 Wo�„� tWcoa, �,,o� p O O N o o' p Z I N rn o r- o 0, rn � O Z OLA B. COLEMAN D.B. 12119, PAGE 2553 n U' o L„I o t„I I o ➢ construed to permit any violation of city, State or Federal law, All Construction \ y� 1 0➢c� rn- N o �O G� �, m(n O' 0 I �+ n r D. B. 3422, PAGE 2 PIN # 1702.10- 36-1340 \I ' C� z I must be in accordance withall Local, State, and Federal Rules and Regulations. N rnG>� 1 p� O 0O I I r. -� I o r B.M. 1968, PAGE 31 ,��r�m 1 mCr)0) NVG� p 1 °vm� / DRAWN BY DJM J O I O N N j O I �m m Z PIN# 1702.10-36-0208 N/F 8"X6" TEE AND 6" VALVE TO I TRANSPORTATION FIELD SERVICES Cr)0, oo w N I 1 �" N ➢ o I BENNIE L. DAVIS s 6" DIP HYDRANT LEG CHECKED BY HWD '`' � rn c9 w Z C & BOBBIE J. DAVIS P013LIC UTILITIES I SCALE: 1" = 30 n CP O � N .A (I1 Cr) 6, N O D.B. 4566, PAGE 658 I I I I I ROPOSED HYDRANT (TYP) B.M. 1968, PAGE 31 5rORMWATEIR n o 15 30 60 .G II I BX TAPPING L G P LAiU 41sG�ZOWI M G STAINLEST LLCRCUMG UTILITY PLAN EAST I I O AD FIRE NES R / N �� URBAN FORESTRY I I � 5D> P gLIC — \ I I 0 SITE ACCESSIBILITY Cm6n0l UTILITY NOTES THE LOCAL JURISDICTIONAL REQUIREMENTS AND STANDARDS. 1. UNLESS OTHERWISE NOTED, ALL MANHOLES SHALL BE PRE —CAST 4. THE CONTRACTOR SHALL COORDINATE ALL PEDESTRIAN AND VEHICULAR 8. ELEVATIONS OF UTILITIES ARE GIVEN TO THE EXTENT OF INFORMATION CONCRETE STRUCTURES. INTERRUPTIONS WITH OWNER'S REPRESENTATIVE AT LEAST 72 HOURS AVAILABLE, WHERE ELEVATIONS ARE NOT GIVEN AT POINTS OF EXISTING PRIOR TO BEGINNING WORK. 7. ALL EXISTING SUB —SURFACE UTILITIES IDENTIFIED ON THE CONSTRUCTION UTILITY CROSSINGS, SUCH ELEVATIONS SHALL BE DETERMINED BY THE 2. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF DOCUMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON CONTRACTOR AND REPORTED TO THE ENGINEER, WHEN UNKNOWN LINES UNDERGROUND UTILITIES (WATER, SEWER, STORM, ELECTRICAL, GAS, OR 5. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK INSIDE THE SURVEY INFORMATION GATHERED FROM FIELD INSPECTION AND/OR ANY ARE EXPOSED, THEIR LOCATIONS AND ELEVATIONS SHALL ALSO BE OTHER) FOR THIS PROJECT WITH THE BUILDING PLANS. THE UTILITY PUBLIC RIGHT OF WAY PRIOR TO RECEIPT AND COMPLIANCE WITH ALL OTHER APPLICABLE RECORD DRAWINGS WHICH MAY BE AVAILABLE. DEPTHS REPORTED TO THE ENGINEER. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE INSTALLATION OF APPLICABLE NCDOT PERMITS. ADDITIONALLY, THE CONTRACTOR SHALL BE OF EXISTING UTILITIES SHOWN IN PROFILE VIEWS ARE BASED ON ALL UTILITY SERVICES TO WITHIN FIVE (5) FEET OF THE BUILDING RESPONSIBLE FOR PROVIDING ALL NECESSARY FLAGGERS AND TRAFFIC STANDARD ASSUMPTIONS. THE CONTRACTOR SHALL FIELD VERIFY THE 9. UNDERGROUND UTILITIES SHOWN ON THIS PLAN SHALL BE INSTALLED CONNECTION POINT. CONTROL DURING ALL WORK INSIDE THE PUBLIC RIGHTS OF WAY. EXACT LOCATION, DEPTH, SIZE AND MATERIAL OF ANY AND ALL PRIOR TO ANY CONSTRUCTION OF PARKING AREA, DRIVES, CURB AND SUB —SURFACE CONDITIONS REFERENCED IN THESE PLANS PRIOR TO ANY GUTTER OR CONCRETE WALKS / PADS. IF UTILITIES SHOWN ON THIS 3. THE CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS ON SITE 6. THE CONTRACTOR SHALL NOT RE —USE ANY FIRE HYDRANT REMOVED AS EXCAVATION OR CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL PLAN CANNOT BE INSTALLED PRIOR TO INSTALLATION OF IMPERVIOUS AND UTILITY PROVIDERS DURING CONSTRUCTION TO ENSURE SMOOTH PART OF THIS PROJECT. ANY FIRE HYDRANT SHOWN TO BE REMOVED OR IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE OF ANY (ASPHALT / CONCRETE) CONDUIT SHALL BE INSTALLED FOR THE "FUTURE" TRANSITION BETWEEN DISCIPLINES. RELOCATED SHALL BE REPLACED WITH A NEW FIRE HYDRANT MEETING DISCREPANCIES OR CONFLICTS. UTILITY INSTALLATION. / / V V / f` / P 0 Q / �i / / INV:258. INV:260'14 INV:260.92' INV: .43'\ GRAVEL CONCRETE /Q, PP EXISTING IVATE DRAINA MENT B.M. 201 1378 MARBLE STREET ' 50' FH PUBLIC R In/ /VV S � / IN 59.00' SIGN N&e SIGNle ' INV: 57.92' pp ,� / / / ICE INV:25 .99' PP pp INV:2 .36' �\ INV:255.1 / PP P /INV:254.0 ' V 10. AS —BUILT DOCUMENTATION REQUIREMENTS: PRIOR TO APPROVAL FROM LOCAL JURISDICTION OR ENGINEER THE CONTRACTOR SHALL PROVIDE AS —BUILT DRAWINGS (IN BOTH PAPER AND ELECTRONIC FORMAT (CAD / PDF) PREPARED AND SEALED BY A PROFESSIONAL LAND SURVEYOR SHOWING ALL UTILITY INSTALLATION. HORIZONTAL AND VERTICAL INFORMATION SHALL BE PROVIDED FOR WATER, SEWER, STORM INCLUDING ALL STRUCTURES, VALVES, HYDRANTS, AND OTHER APPURTENANCES. �i C' V:254 \� _..... / N/F EARL R. DAVIS D.B. 8238, PAGE 687 B.M. 1988, PAGE 257 PIN # 1702.10— 37— 7132 �12 PP /INV:261.60' \ I N/F / LEWIS DOWNEY / T PRIVATE \ �-- D.B. 9272, PAGE 1111 ��B.M. 1956, PAGE 61 / / V:262.57' / ::�`` ,/ I SEMENT \ N/F WASHINGTON E. POUT PIN# 1702.10-36-4995 Q 01 / ` 1 P GE 526 \\ � JUAN PABLO CONSTANZA I D.B. 16172, PAGE 1192 D.B. 13694, PAGE 342 / B.M. 1956, PAGE 61 ' ' B.M. 1956 PAGE 61 \ PIN# 1702.10-36-5974 NNECTION �� / , \ ' i S % \ �� �`` /� PIN# 1702.10-36-4913 I / N F \ V. 263.59 / / I \ RAYMOND LEE AVERY JR. / �Q IN .265.59' D.B. 4078, PAGE 631 B.M. 1956 PAGE 61 \� PIN# 1702.10-36-3950 PP N/F SANTOS ELIAS CONSTANZA / �� .. •..�. �� \� `1..,�..\ 9 / D.B. 12656, PAGE 2695 B.M. 1956, PAGE 61 o GRANITE STREET PECAN ROAD � MgRkF S w W � F� AR UNA P'NES AVENUE gJ� �F, CT Ld SITE 7 VICINITY MAP N.T.S. SURVEY DISCLAIMER SURVEY INFORMATION PREPARED BY L. JORDAN PARKER (PLS L-4665) ON FEBRUARY X, 2019. CAWTHORNE, MOSS, & PANCIERA, PC, 333 S. WHITE STREET, WAKE FOREST, INC 27588 D R Y E i *w *wk4w �wkaw, McGLAMERY ENGINEERING, PLLC NC FIRM LICENSE #P-1305 ISSUED FOR REVIEW NOT FOR CONSTRUCTION SYMBOL DESCRIPTION �T W EXISTING WATER LINE 1 a W PROPOSED WATER LINE SS EXISTING SANITARY SEWER LINE SS PROPOSED SANITARY SEWER LINE Xf PROPOSED FIRE HYDRANT ® PROPOSED WATER VALVE O EXISTING SANITARY SEWER MANHOLE E O PROPOSED SANITARY SEWER MANHOLE 60 PROPOSED CLEANOUT PROPOSED FDC FO PROPOSED BACKFLOW METER PIV • PROPOSED POST INDICATOR VALVE (PIV) 000 GREASE INTERCEPTOR 300' HYDRANT COVERAGE CIRCLE LIMITS OF DISTURBANCE NOTE. REFER TO TRANSPORTATION PLAN C-2.1 FOR EXISTING STREET AND RIGHT-OF-WAY DIMENSIONS } J M 0 N ILL H H J � W � J ��� �0a z LLJ 0- 0 Z Z} N � w U Z 0 Y N J Z� U E ILL ULLU ZO2=()U JJ U' LLI _ LLJ2 W' ZW� LU 04 C�Z�W)004� OL~cQ ISSUED FOR REV I DESRIPTION I DATE A ISSUED FOR REVIEW 08.11.2020 \ CONCURRENT REVIEW APPROVAL CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION \ Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction IS not to aes t" id2ma'd tb eq tprmt%nt t6tal t6n5olianeea With all IgAl requireme n" for development and carstrudion, The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specffic auOcwixadon below is not a permit, nor shall It be construed to perrnft any violation of Clty, State or Federal Law. All Construction must be in accordance with all local, State, and Federal Rules and Regulations. DRAWN BY DJM TRANSPORTATION FIELD SERVICES CHECKED BY HWD PUBLIC UTILITI E5 SCALE: 1" = 30 S'CORMWATER 0 15 30 60 PLANNINGJZOf1ING UTILITY PLAN NORTH FIRE URBAN FORE57RY SITE ACCESSIBILITY Cm6n02 UTILITY