Loading...
HomeMy WebLinkAbout780035_Inspection_20200707 rC (',f)7(.17V 0 Division of Water Resources Facility Number I l n l - j 6 0 Division of Soil and Water Conservation 0 Other Agency Type of Visit: ©-Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: td1 utine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit:( 7- 1.0 Arrival Time:(/, /0 Departure Time:L; v County: ,,�p� Region: F :) Farm Name: Y .q. ry #2, Owner Email: Owner Name: U r/y� L,L- Phone: Mailing Address: ilVg d 7--er Physical Address: Facility Contact: /31,c,Kq.r I J,t Title: Awn--i'" Phone: 970 Onsite Representative: Sd mac_ Integrator: .j �� Certified Operator: Certification Number: Back-up Operator: Certification Number: Location of Farm: Latitude: Longitude: Design Current Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Cattle Capacity Pop. Wean to Finish Layer Dairy Cow _ Wean to Feeder Non-Layer Dairy Calf I./feeder to Finish 3 9ry Dairy Heifer Farrow to Wean Design Current Dry Cow Farrow to Feeder _ D Poul Ca aci Po I. Non-Dairy Farrow to Finish _ • -- Beef Stocker Gilts •Non-La ers -- Beef Feeder Boars •Pullets -- Beef Brood Cow EMMEN Other •Turke Poults Other •Other Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes Li-No ❑ NA ❑ NE Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? ❑ Yes ❑ No ❑ NA ❑ NE b. Did the discharge reach waters of the State?(If yes,notify DWR) ❑ Yes ❑ No ❑ NA ❑ NE c. What is the estimated volume that reached waters of the State(gallons)? d. Does the discharge bypass the waste management system?(If yes,notify DWR) ❑ Yes 0 No ❑ NA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? ❑ Yes No ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes IIo ❑ NA ❑ NE of the State other than from a discharge? Page 1 of 3 2/4/2015 Continued Facility Number: 78 (Date of Inspection: 7-7—,a),41 Waste Collection&Treatment 4.Is storage capacity(structural plus storm storage plus heavy rainfall)less than adequate? ❑ Yes E No ❑ NA ❑ NE a. If yes,is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard(in): // Observed Freeboard(in): 5.Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes la-No ❑ NA ❑ NE (i.e.,large trees,severe erosion,seepage,etc.) 6.Are there structures on-site which are not properly addressed and/or managed through a ❑ Yes ❑/"No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes,and the situation poses an immediate public health or environmental threat,notify DWR 7.Do any of the structures need maintenance or improvement? I Yes ❑ No D NA ❑ NE 8.Do any of the structures lack adequate markers as required by the permit? D Yes 13 o ❑ NA ❑ NE (not applicable to roofed pits,dry stacks,and/or wet stacks) 9.Does any part of the waste management system other than the waste structures require ❑ Yes E No ❑ NA ❑ NE maintenance or improvement? Waste Application 10.Are there any required buffers,setbacks,or compliance alternatives that need ❑ Yes ENo ❑ NA ❑ NE maintenance or improvement? 11.Is there evidence of incorrect land application?If yes,check the appropriate box below. ❑ Yes 1No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals(Cu,Zn,etc.) ❑ PAN ❑ PAN> 10%or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12.Crop Type(s): .,�2erfril l 0e/ - i 1 13. Soil Type(s): tazjel/a,-12 /ck it- 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes ❑ No ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? [ Yes ❑ No ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable [r]'Yes ❑ No ❑ NA ❑ NE acres determination? 17.Does the facility lack adequate acreage for land application? ❑ Yes Ergo ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes ❑ ❑ NA D NE Required Records&Documents 19. Did the facility fail to have the Certificate of Coverage&Permit readily available? ❑ Yes J i 10 ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available?If yes,check ❑ Yes Q o ❑ NA ❑ NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑Maps ❑ Lease Agreements ❑Other: 21.Does record keeping need improvement? If yes,check the appropriate box below. ❑ Yes No ❑ NA ❑ NE ❑Waste Application ❑Weekly Freeboard El Waste Analysis ❑Soil Analysis ❑Waste Transfers ❑Weather Code ❑Rainfall ❑Stocking ❑Crop Yield ❑120 Minute Inspections ❑Monthly and 1"Rainfall Inspections ❑Sludge Survey 22.Did the facility fail to install and maintain a rain gauge? ❑ Yes []No ❑ NA ❑ NE 23. If selected,did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes No ❑ NA ❑ NE Page 2 of 3 2/4/2015 Continued Facility Number: 78 - 3S Date of Inspection: 7 T 24.Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes To ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes,check ❑ Yes la go ❑ NA ❑ NE the appropriate box(es)below. ❑Failure to complete annual sludge survey ❑Failure to develop a POA for sludge levels ❑Non-compliant sludge levels in any lagoon List structure(s)and date of first survey indicating non-compliance: 26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes To ❑ NA ❑ NE 27.Did the facility fail to secure a phosphorus loss assessments(PLAT)certification? ❑ Yes [ago ❑ NA ❑ NE Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes [r]No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29.At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes [j1Z ❑ NA ❑ NE If yes,contact a regional Air Quality representative immediately. 30.Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes Io ❑ NA ❑ NE permit?(i.e.,discharge,freeboard problems,over-application) 31. Do subsurface tile drains exist at the facility?If yes,check the appropriate box below. ❑ Yes la< ❑ NA ❑ NE ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes 0lCrc.: ❑ NA ❑ NE 33.Did the Reviewer/Inspector fail to discuss review/inspection with an on-site representative? ❑ Yes ❑' ❑ NA ❑ NE 34.Does the facility require a follow-up visit by the same agency? ❑ Yes ❑-.N6 ❑ NA ❑ NE Comments(refer to question#):Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations(use additional� pages as necessary). / 7 07itul 1-a ,'-'' 'n`Ta7 8 4* `0 kr-72)r /--irlot Tltr.0 tars 7-'✓45-r'z ` 4 o• ��'�/ /� are id:,fee-6o«1 f9 11r oa%c) r-te"r a-4 drs nYel % Hb I,v u7. /"cea pi-ft r[avet X-r-a'`y A+$ .3�°7 Y/e" LA" Reviewer/Inspector Name: ri�� —rj- Phone: "IQ"�0.3—e)/5 Reviewer/Inspector Signature: /S Date: 7 7%vd/?-fl Page 3 of 3 2/4/2015